Class: Analog
_Analog represents an analog Measurement. _
__
URI: cim:Analog
classDiagram
class Analog
Measurement <|-- Analog
Analog : alias_name
Analog : analog_values
Analog --> AnalogValue : analog_values
Analog : description
Analog : m_rid
Analog : max_value
Analog : measurement_type
Analog : min_value
Analog : names
Analog --> Name : names
Analog : normal_value
Analog : phases
Analog --> PhaseCode : phases
Analog : positive_flow_in
Analog : power_system_resource
Analog --> PowerSystemResource : power_system_resource
Analog : terminal
Analog --> ACDCTerminal : terminal
Analog : unit_multiplier
Analog --> UnitMultiplier : unit_multiplier
Analog : unit_symbol
Analog --> UnitSymbol : unit_symbol
Inheritance
- IdentifiedObject
- Measurement
- Analog
- Measurement
Slots
Name | Cardinality and Range | Description | Inheritance |
---|---|---|---|
max_value | 0..1 Float |
Normal value range maximum for any of the MeasurementValue | direct |
min_value | 0..1 Float |
Normal value range minimum for any of the MeasurementValue | direct |
normal_value | 0..1 Float |
Normal measurement value, e | direct |
positive_flow_in | 0..1 Boolean |
If true then this measurement is an active power, reactive power or current w... | direct |
analog_values | 0..* AnalogValue |
The values connected to this measurement | direct |
measurement_type | 0..1 String |
Specifies the type of measurement | Measurement |
phases | 0..1 PhaseCode |
Indicates to which phases the measurement applies and avoids the need to use ... | Measurement |
unit_multiplier | 0..1 UnitMultiplier |
The unit multiplier of the measured quantity | Measurement |
unit_symbol | 0..1 UnitSymbol |
The unit of measure of the measured quantity | Measurement |
terminal | 0..1 ACDCTerminal |
One or more measurements may be associated with a terminal in the network | Measurement |
power_system_resource | 0..1 PowerSystemResource |
The power system resource that contains the measurement | Measurement |
alias_name | 0..1 String |
The aliasName is free text human readable name of the object alternative to I... | IdentifiedObject |
description | 0..1 String |
The description is a free human readable text describing or naming the object | IdentifiedObject |
m_rid | 0..1 String |
Master resource identifier issued by a model authority | IdentifiedObject |
names | 0..* Name |
All names of this identified object | IdentifiedObject |
Usages
used by | used in | type | used |
---|---|---|---|
AnalogValue | analog | range | Analog |
Identifier and Mapping Information
Schema Source
- from schema: https://cim.ucaiug.io/ns#TC57CIM
Mappings
Mapping Type | Mapped Value |
---|---|
self | cim:Analog |
native | this:Analog |
LinkML Source
Direct
name: Analog
description: "Analog represents an analog Measurement.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
is_a: Measurement
attributes:
max_value:
name: max_value
description: Normal value range maximum for any of the MeasurementValue.values.
Used for scaling, e.g. in bar graphs or of telemetered raw values.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Analog.maxValue
multivalued: false
domain_of:
- Analog
- Accumulator
range: float
required: false
min_value:
name: min_value
description: "Normal value range minimum for any of the MeasurementValue.values.\
\ Used for scaling, e.g. in bar graphs or of telemetered raw values.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Analog.minValue
multivalued: false
domain_of:
- Analog
range: float
required: false
normal_value:
name: normal_value
description: Normal measurement value, e.g., used for percentage calculations.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Analog.normalValue
multivalued: false
domain_of:
- Analog
range: float
required: false
positive_flow_in:
name: positive_flow_in
description: If true then this measurement is an active power, reactive power
or current with the convention that a positive value measured at the Terminal
means power is flowing into the related PowerSystemResource.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Analog.positiveFlowIn
multivalued: false
domain_of:
- Analog
range: boolean
required: false
analog_values:
name: analog_values
description: The values connected to this measurement.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Analog.AnalogValues
multivalued: true
domain_of:
- Analog
range: AnalogValue
required: false
class_uri: cim:Analog
Induced
name: Analog
description: "Analog represents an analog Measurement.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
is_a: Measurement
attributes:
max_value:
name: max_value
description: Normal value range maximum for any of the MeasurementValue.values.
Used for scaling, e.g. in bar graphs or of telemetered raw values.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Analog.maxValue
multivalued: false
alias: max_value
owner: Analog
domain_of:
- Analog
- Accumulator
range: float
required: false
min_value:
name: min_value
description: "Normal value range minimum for any of the MeasurementValue.values.\
\ Used for scaling, e.g. in bar graphs or of telemetered raw values.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Analog.minValue
multivalued: false
alias: min_value
owner: Analog
domain_of:
- Analog
range: float
required: false
normal_value:
name: normal_value
description: Normal measurement value, e.g., used for percentage calculations.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Analog.normalValue
multivalued: false
alias: normal_value
owner: Analog
domain_of:
- Analog
range: float
required: false
positive_flow_in:
name: positive_flow_in
description: If true then this measurement is an active power, reactive power
or current with the convention that a positive value measured at the Terminal
means power is flowing into the related PowerSystemResource.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Analog.positiveFlowIn
multivalued: false
alias: positive_flow_in
owner: Analog
domain_of:
- Analog
range: boolean
required: false
analog_values:
name: analog_values
description: The values connected to this measurement.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Analog.AnalogValues
multivalued: true
alias: analog_values
owner: Analog
domain_of:
- Analog
range: AnalogValue
required: false
measurement_type:
name: measurement_type
description: "Specifies the type of measurement. For example, this specifies\
\ if the measurement represents an indoor temperature, outdoor temperature,\
\ bus voltage, line flow, etc.\r\nWhen the measurementType is set to \"Specialization\"\
, the type of Measurement is defined in more detail by the specialized class\
\ which inherits from Measurement.\r\n\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Measurement.measurementType
multivalued: false
alias: measurement_type
owner: Analog
domain_of:
- Measurement
range: string
required: false
phases:
name: phases
description: "Indicates to which phases the measurement applies and avoids the\
\ need to use 'measurementType' to also encode phase information (which would\
\ explode the types). The phase information in Measurement, along with 'measurementType'\
\ and 'phases' uniquely defines a Measurement for a device, based on normal\
\ network phase. Their meaning will not change when the computed energizing\
\ phasing is changed due to jumpers or other reasons.\r\nIf the attribute is\
\ missing three phases (ABC) shall be assumed."
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Measurement.phases
multivalued: false
alias: phases
owner: Analog
domain_of:
- Measurement
- Terminal
range: PhaseCode
required: false
unit_multiplier:
name: unit_multiplier
description: The unit multiplier of the measured quantity.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Measurement.unitMultiplier
multivalued: false
alias: unit_multiplier
owner: Analog
domain_of:
- Measurement
range: UnitMultiplier
required: false
unit_symbol:
name: unit_symbol
description: The unit of measure of the measured quantity.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Measurement.unitSymbol
multivalued: false
alias: unit_symbol
owner: Analog
domain_of:
- Measurement
range: UnitSymbol
required: false
terminal:
name: terminal
description: One or more measurements may be associated with a terminal in the
network.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Measurement.Terminal
multivalued: false
alias: terminal
owner: Analog
domain_of:
- Measurement
- AuxiliaryEquipment
range: ACDCTerminal
required: false
power_system_resource:
name: power_system_resource
description: The power system resource that contains the measurement.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Measurement.PowerSystemResource
multivalued: false
alias: power_system_resource
owner: Analog
domain_of:
- Measurement
- PSREvent
range: PowerSystemResource
required: false
alias_name:
name: alias_name
description: "The aliasName is free text human readable name of the object alternative\
\ to IdentifiedObject.name. It may be non unique and may not correlate to a\
\ naming hierarchy.\r\nThe attribute aliasName is retained because of backwards\
\ compatibility between CIM relases. It is however recommended to replace aliasName\
\ with the Name class as aliasName is planned for retirement at a future time.\r\
\n\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.aliasName
multivalued: false
alias: alias_name
owner: Analog
domain_of:
- IdentifiedObject
range: string
required: false
description:
name: description
description: The description is a free human readable text describing or naming
the object. It may be non unique and may not correlate to a naming hierarchy.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.description
multivalued: false
alias: description
owner: Analog
domain_of:
- IdentifiedObject
- NameType
- NameTypeAuthority
range: string
required: false
m_rid:
name: m_rid
description: "Master resource identifier issued by a model authority. The mRID\
\ is unique within an exchange context. Global uniqueness is easily achieved\
\ by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is\
\ strongly recommended.\r\nFor CIMXML data files in RDF syntax conforming to\
\ IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify\
\ CIM object elements."
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.mRID
multivalued: false
alias: m_rid
owner: Analog
domain_of:
- IdentifiedObject
range: string
required: false
names:
name: names
description: All names of this identified object.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.Names
multivalued: true
alias: names
owner: Analog
domain_of:
- IdentifiedObject
- NameType
range: Name
required: false
class_uri: cim:Analog