Class: Reactance
Reactance (imaginary part of impedance), at rated frequency.
URI: cim:Reactance
classDiagram
class Reactance
Reactance : Reactance.multiplier
Reactance --> UnitMultiplier : Reactance.multiplier
Reactance : Reactance.unit
Reactance --> UnitSymbol : Reactance.unit
Reactance : Reactance.value
Slots
Name | Cardinality and Range | Description | Inheritance |
---|---|---|---|
value | 0..1 Float |
direct | |
unit | 0..1 UnitSymbol |
direct | |
multiplier | 0..1 UnitMultiplier |
direct |
Usages
used by | used in | type | used |
---|---|---|---|
ACLineSegment | x | range | Reactance |
PowerTransformerEnd | x | range | Reactance |
Identifier and Mapping Information
Schema Source
- from schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
Mappings
Mapping Type | Mapped Value |
---|---|
self | cim:Reactance |
native | this:Reactance |
LinkML Source
Direct
name: Reactance
description: Reactance (imaginary part of impedance), at rated frequency.
from_schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
rank: 1000
attributes:
value:
name: value
from_schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
slot_uri: cim:Reactance.value
multivalued: false
domain_of:
- Susceptance
- Conductance
- Resistance
- Reactance
- Length
- Voltage
- CurrentFlow
- ActivePower
- PerCent
- ReactivePower
range: float
required: false
unit:
name: unit
from_schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
slot_uri: cim:Reactance.unit
multivalued: false
domain_of:
- Susceptance
- Conductance
- Resistance
- Reactance
- Length
- Voltage
- CurrentFlow
- ActivePower
- PerCent
- ReactivePower
range: UnitSymbol
required: false
multiplier:
name: multiplier
from_schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
slot_uri: cim:Reactance.multiplier
multivalued: false
domain_of:
- Susceptance
- Conductance
- Resistance
- Reactance
- Length
- Voltage
- CurrentFlow
- ActivePower
- PerCent
- ReactivePower
range: UnitMultiplier
required: false
class_uri: cim:Reactance
Induced
name: Reactance
description: Reactance (imaginary part of impedance), at rated frequency.
from_schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
rank: 1000
attributes:
value:
name: value
from_schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
slot_uri: cim:Reactance.value
multivalued: false
alias: value
owner: Reactance
domain_of:
- Susceptance
- Conductance
- Resistance
- Reactance
- Length
- Voltage
- CurrentFlow
- ActivePower
- PerCent
- ReactivePower
range: float
required: false
unit:
name: unit
from_schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
slot_uri: cim:Reactance.unit
multivalued: false
alias: unit
owner: Reactance
domain_of:
- Susceptance
- Conductance
- Resistance
- Reactance
- Length
- Voltage
- CurrentFlow
- ActivePower
- PerCent
- ReactivePower
range: UnitSymbol
required: false
multiplier:
name: multiplier
from_schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
slot_uri: cim:Reactance.multiplier
multivalued: false
alias: multiplier
owner: Reactance
domain_of:
- Susceptance
- Conductance
- Resistance
- Reactance
- Length
- Voltage
- CurrentFlow
- ActivePower
- PerCent
- ReactivePower
range: UnitMultiplier
required: false
class_uri: cim:Reactance