Class: PowerTransformer
An electrical device consisting of two or more coupled windings, with or without a magnetic core, for introducing mutual coupling between electric circuits. Transformers can be used to control voltage and phase shift (active power flow).
A power transformer may be composed of separate transformer tanks that need not be identical.
A power transformer can be modelled with or without tanks and is intended for use in both balanced and unbalanced representations. A power transformer typically has two terminals, but may have one (grounding), three or more terminals.
The inherited association ConductingEquipment.BaseVoltage should not be used. The association from TransformerEnd to BaseVoltage should be used instead.
URI: cim:PowerTransformer
classDiagram
class PowerTransformer
ConductingEquipment <|-- PowerTransformer
PowerTransformer : Equipment.aggregate
PowerTransformer : ConductingEquipment.BaseVoltage
PowerTransformer --> BaseVoltage : ConductingEquipment.BaseVoltage
PowerTransformer : IdentifiedObject.description
PowerTransformer : IdentifiedObject.energyIdentCodeEic
PowerTransformer : Equipment.EquipmentContainer
PowerTransformer --> EquipmentContainer : Equipment.EquipmentContainer
PowerTransformer : IdentifiedObject.mRID
PowerTransformer : IdentifiedObject.Names
PowerTransformer --> Name : IdentifiedObject.Names
PowerTransformer : Equipment.normallyInService
PowerTransformer : PowerTransformer.PowerTransformerEnd
PowerTransformer --> PowerTransformerEnd : PowerTransformer.PowerTransformerEnd
PowerTransformer : IdentifiedObject.shortName
PowerTransformer : ConductingEquipment.Terminals
PowerTransformer --> Terminal : ConductingEquipment.Terminals
Inheritance
- IdentifiedObject
- PowerSystemResource
- Equipment
- ConductingEquipment
- PowerTransformer
- ConductingEquipment
- Equipment
- PowerSystemResource
Slots
Name | Cardinality and Range | Description | Inheritance |
---|---|---|---|
power_transformer_end | 0..* PowerTransformerEnd |
The ends of this power transformer | direct |
base_voltage | 0..1 BaseVoltage |
Base voltage of this conducting equipment | ConductingEquipment |
terminals | 0..* Terminal |
Conducting equipment have terminals that may be connected to other conducting... | ConductingEquipment |
aggregate | 0..1 Boolean |
The aggregate flag provides an alternative way of representing an aggregated ... | Equipment |
normally_in_service | 0..1 Boolean |
Specifies the availability of the equipment under normal operating conditions | Equipment |
equipment_container | 0..1 EquipmentContainer |
Container of this equipment | Equipment |
description | 0..1 String |
The description is a free human readable text describing or naming the object | IdentifiedObject |
energy_ident_code_eic | 0..1 String |
The attribute is used for an exchange of the EIC code (Energy identification ... | IdentifiedObject |
m_rid | 1..1 String |
Master resource identifier issued by a model authority | IdentifiedObject |
short_name | 0..1 String |
The attribute is used for an exchange of a human readable short name with len... | IdentifiedObject |
names | 0..* Name |
All names of this identified object | IdentifiedObject |
Usages
used by | used in | type | used |
---|---|---|---|
PowerTransformerEnd | power_transformer | range | PowerTransformer |
Identifier and Mapping Information
Schema Source
- from schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
Mappings
Mapping Type | Mapped Value |
---|---|
self | cim:PowerTransformer |
native | this:PowerTransformer |
LinkML Source
Direct
name: PowerTransformer
description: 'An electrical device consisting of two or more coupled windings, with
or without a magnetic core, for introducing mutual coupling between electric circuits.
Transformers can be used to control voltage and phase shift (active power flow).
A power transformer may be composed of separate transformer tanks that need not
be identical.
A power transformer can be modelled with or without tanks and is intended for use
in both balanced and unbalanced representations. A power transformer typically
has two terminals, but may have one (grounding), three or more terminals.
The inherited association ConductingEquipment.BaseVoltage should not be used. The
association from TransformerEnd to BaseVoltage should be used instead.'
from_schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
rank: 1000
is_a: ConductingEquipment
attributes:
power_transformer_end:
name: power_transformer_end
description: The ends of this power transformer.
from_schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
rank: 1000
slot_uri: cim:PowerTransformer.PowerTransformerEnd
multivalued: true
domain_of:
- PowerTransformer
range: PowerTransformerEnd
required: false
class_uri: cim:PowerTransformer
Induced
name: PowerTransformer
description: 'An electrical device consisting of two or more coupled windings, with
or without a magnetic core, for introducing mutual coupling between electric circuits.
Transformers can be used to control voltage and phase shift (active power flow).
A power transformer may be composed of separate transformer tanks that need not
be identical.
A power transformer can be modelled with or without tanks and is intended for use
in both balanced and unbalanced representations. A power transformer typically
has two terminals, but may have one (grounding), three or more terminals.
The inherited association ConductingEquipment.BaseVoltage should not be used. The
association from TransformerEnd to BaseVoltage should be used instead.'
from_schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
rank: 1000
is_a: ConductingEquipment
attributes:
power_transformer_end:
name: power_transformer_end
description: The ends of this power transformer.
from_schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
rank: 1000
slot_uri: cim:PowerTransformer.PowerTransformerEnd
multivalued: true
alias: power_transformer_end
owner: PowerTransformer
domain_of:
- PowerTransformer
range: PowerTransformerEnd
required: false
base_voltage:
name: base_voltage
description: Base voltage of this conducting equipment. Use only when there is
no voltage level container used and only one base voltage applies. For example,
not used for transformers.
from_schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
rank: 1000
slot_uri: cim:ConductingEquipment.BaseVoltage
multivalued: false
alias: base_voltage
owner: PowerTransformer
domain_of:
- ConductingEquipment
- VoltageLevel
- TransformerEnd
range: BaseVoltage
required: false
terminals:
name: terminals
description: Conducting equipment have terminals that may be connected to other
conducting equipment terminals via connectivity nodes or topological nodes.
from_schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
rank: 1000
slot_uri: cim:ConductingEquipment.Terminals
multivalued: true
alias: terminals
owner: PowerTransformer
domain_of:
- ConductingEquipment
- ConnectivityNode
range: Terminal
required: false
aggregate:
name: aggregate
description: "The aggregate flag provides an alternative way of representing an\
\ aggregated (equivalent) element. It is applicable in cases when the dedicated\
\ classes for equivalent equipment do not have all of the attributes necessary\
\ to represent the required level of detail. In case the flag is set to “true”\
\ the single instance of equipment represents multiple pieces of equipment that\
\ have been modelled together as an aggregate equivalent obtained by a network\
\ reduction procedure. Examples would be power transformers or synchronous machines\
\ operating in parallel modelled as a single aggregate power transformer or\
\ aggregate synchronous machine. \nThe attribute is not used for EquivalentBranch,\
\ EquivalentShunt and EquivalentInjection."
from_schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
rank: 1000
slot_uri: cim:Equipment.aggregate
multivalued: false
alias: aggregate
owner: PowerTransformer
domain_of:
- Equipment
range: boolean
required: false
normally_in_service:
name: normally_in_service
description: Specifies the availability of the equipment under normal operating
conditions. True means the equipment is available for topology processing, which
determines if the equipment is energized or not. False means that the equipment
is treated by network applications as if it is not in the model.
from_schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
rank: 1000
slot_uri: cim:Equipment.normallyInService
multivalued: false
alias: normally_in_service
owner: PowerTransformer
domain_of:
- Equipment
range: boolean
required: false
equipment_container:
name: equipment_container
description: Container of this equipment.
from_schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
rank: 1000
slot_uri: cim:Equipment.EquipmentContainer
multivalued: false
alias: equipment_container
owner: PowerTransformer
domain_of:
- Equipment
range: EquipmentContainer
required: false
description:
name: description
description: The description is a free human readable text describing or naming
the object. It may be non unique and may not correlate to a naming hierarchy.
from_schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
rank: 1000
slot_uri: cim:IdentifiedObject.description
multivalued: false
alias: description
owner: PowerTransformer
domain_of:
- IdentifiedObject
- NameType
- NameTypeAuthority
range: string
required: false
energy_ident_code_eic:
name: energy_ident_code_eic
description: The attribute is used for an exchange of the EIC code (Energy identification
Code). The length of the string is 16 characters as defined by the EIC code.
For details on EIC scheme please refer to ENTSO-E web site.
from_schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
rank: 1000
slot_uri: eu:IdentifiedObject.energyIdentCodeEic
multivalued: false
alias: energy_ident_code_eic
owner: PowerTransformer
domain_of:
- IdentifiedObject
range: string
required: false
m_rid:
name: m_rid
description: 'Master resource identifier issued by a model authority. The mRID
is unique within an exchange context. Global uniqueness is easily achieved by
using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly
recommended.
For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is
mapped to rdf:ID or rdf:about attributes that identify CIM object elements.'
from_schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
rank: 1000
slot_uri: cim:IdentifiedObject.mRID
multivalued: false
alias: m_rid
owner: PowerTransformer
domain_of:
- IdentifiedObject
range: string
required: true
short_name:
name: short_name
description: The attribute is used for an exchange of a human readable short name
with length of the string 12 characters maximum.
from_schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
rank: 1000
slot_uri: eu:IdentifiedObject.shortName
multivalued: false
alias: short_name
owner: PowerTransformer
domain_of:
- IdentifiedObject
range: string
required: false
names:
name: names
description: All names of this identified object.
from_schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
rank: 1000
slot_uri: cim:IdentifiedObject.Names
multivalued: true
alias: names
owner: PowerTransformer
domain_of:
- IdentifiedObject
- NameType
range: Name
required: false
class_uri: cim:PowerTransformer