Class: IdentifiedObject

This is a root class to provide common identification for all classes needing identification and naming attributes.

URI: cim:IdentifiedObject

 classDiagram
    class IdentifiedObject
      IdentifiedObject <|-- BaseVoltage
      IdentifiedObject <|-- TransformerEnd
      IdentifiedObject <|-- ConnectivityNode
      IdentifiedObject <|-- PowerSystemResource
      IdentifiedObject <|-- ACDCTerminal
      IdentifiedObject <|-- AssetInfo

      IdentifiedObject : IdentifiedObject.description

      IdentifiedObject : IdentifiedObject.energyIdentCodeEic

      IdentifiedObject : IdentifiedObject.mRID

      IdentifiedObject : IdentifiedObject.Names

          IdentifiedObject --> Name : IdentifiedObject.Names

      IdentifiedObject : IdentifiedObject.shortName

Inheritance

Slots

Name Cardinality and Range Description Inheritance
description 0..1
String
The description is a free human readable text describing or naming the object direct
energy_ident_code_eic 0..1
String
The attribute is used for an exchange of the EIC code (Energy identification ... direct
m_rid 1..1
String
Master resource identifier issued by a model authority direct
short_name 0..1
String
The attribute is used for an exchange of a human readable short name with len... direct
names 0..*
Name
All names of this identified object direct

Usages

used by used in type used
Name identified_object range IdentifiedObject

Identifier and Mapping Information

Schema Source

  • from schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile

Mappings

Mapping Type Mapped Value
self cim:IdentifiedObject
native this:IdentifiedObject

LinkML Source

Direct

name: IdentifiedObject
description: This is a root class to provide common identification for all classes
  needing identification and naming attributes.
from_schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
rank: 1000
attributes:
  description:
    name: description
    description: The description is a free human readable text describing or naming
      the object. It may be non unique and may not correlate to a naming hierarchy.
    from_schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
    rank: 1000
    slot_uri: cim:IdentifiedObject.description
    multivalued: false
    domain_of:
    - IdentifiedObject
    - NameType
    - NameTypeAuthority
    range: string
    required: false
  energy_ident_code_eic:
    name: energy_ident_code_eic
    description: The attribute is used for an exchange of the EIC code (Energy identification
      Code). The length of the string is 16 characters as defined by the EIC code.
      For details on EIC scheme please refer to ENTSO-E web site.
    from_schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
    rank: 1000
    slot_uri: eu:IdentifiedObject.energyIdentCodeEic
    multivalued: false
    domain_of:
    - IdentifiedObject
    range: string
    required: false
  m_rid:
    name: m_rid
    description: 'Master resource identifier issued by a model authority. The mRID
      is unique within an exchange context. Global uniqueness is easily achieved by
      using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly
      recommended.

      For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is
      mapped to rdf:ID or rdf:about attributes that identify CIM object elements.'
    from_schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
    rank: 1000
    slot_uri: cim:IdentifiedObject.mRID
    multivalued: false
    domain_of:
    - IdentifiedObject
    range: string
    required: true
  short_name:
    name: short_name
    description: The attribute is used for an exchange of a human readable short name
      with length of the string 12 characters maximum.
    from_schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
    rank: 1000
    slot_uri: eu:IdentifiedObject.shortName
    multivalued: false
    domain_of:
    - IdentifiedObject
    range: string
    required: false
  names:
    name: names
    description: All names of this identified object.
    from_schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
    rank: 1000
    slot_uri: cim:IdentifiedObject.Names
    multivalued: true
    domain_of:
    - IdentifiedObject
    - NameType
    range: Name
    required: false
class_uri: cim:IdentifiedObject

Induced

name: IdentifiedObject
description: This is a root class to provide common identification for all classes
  needing identification and naming attributes.
from_schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
rank: 1000
attributes:
  description:
    name: description
    description: The description is a free human readable text describing or naming
      the object. It may be non unique and may not correlate to a naming hierarchy.
    from_schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
    rank: 1000
    slot_uri: cim:IdentifiedObject.description
    multivalued: false
    alias: description
    owner: IdentifiedObject
    domain_of:
    - IdentifiedObject
    - NameType
    - NameTypeAuthority
    range: string
    required: false
  energy_ident_code_eic:
    name: energy_ident_code_eic
    description: The attribute is used for an exchange of the EIC code (Energy identification
      Code). The length of the string is 16 characters as defined by the EIC code.
      For details on EIC scheme please refer to ENTSO-E web site.
    from_schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
    rank: 1000
    slot_uri: eu:IdentifiedObject.energyIdentCodeEic
    multivalued: false
    alias: energy_ident_code_eic
    owner: IdentifiedObject
    domain_of:
    - IdentifiedObject
    range: string
    required: false
  m_rid:
    name: m_rid
    description: 'Master resource identifier issued by a model authority. The mRID
      is unique within an exchange context. Global uniqueness is easily achieved by
      using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly
      recommended.

      For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is
      mapped to rdf:ID or rdf:about attributes that identify CIM object elements.'
    from_schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
    rank: 1000
    slot_uri: cim:IdentifiedObject.mRID
    multivalued: false
    alias: m_rid
    owner: IdentifiedObject
    domain_of:
    - IdentifiedObject
    range: string
    required: true
  short_name:
    name: short_name
    description: The attribute is used for an exchange of a human readable short name
      with length of the string 12 characters maximum.
    from_schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
    rank: 1000
    slot_uri: eu:IdentifiedObject.shortName
    multivalued: false
    alias: short_name
    owner: IdentifiedObject
    domain_of:
    - IdentifiedObject
    range: string
    required: false
  names:
    name: names
    description: All names of this identified object.
    from_schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
    rank: 1000
    slot_uri: cim:IdentifiedObject.Names
    multivalued: true
    alias: names
    owner: IdentifiedObject
    domain_of:
    - IdentifiedObject
    - NameType
    range: Name
    required: false
class_uri: cim:IdentifiedObject