Class: Disconnector
A manually operated or motor operated mechanical switching device used for changing the connections in a circuit, or for isolating a circuit or equipment from a source of power. It is required to open or close circuits when negligible current is broken or made.
URI: cim:Disconnector
classDiagram
class Disconnector
Switch <|-- Disconnector
Disconnector : Equipment.aggregate
Disconnector : ConductingEquipment.BaseVoltage
Disconnector --> BaseVoltage : ConductingEquipment.BaseVoltage
Disconnector : IdentifiedObject.description
Disconnector : IdentifiedObject.energyIdentCodeEic
Disconnector : Equipment.EquipmentContainer
Disconnector --> EquipmentContainer : Equipment.EquipmentContainer
Disconnector : IdentifiedObject.mRID
Disconnector : IdentifiedObject.Names
Disconnector --> Name : IdentifiedObject.Names
Disconnector : Switch.normalOpen
Disconnector : Equipment.normallyInService
Disconnector : Switch.ratedCurrent
Disconnector --> CurrentFlow : Switch.ratedCurrent
Disconnector : Switch.retained
Disconnector : IdentifiedObject.shortName
Disconnector : ConductingEquipment.Terminals
Disconnector --> Terminal : ConductingEquipment.Terminals
Inheritance
Slots
Name | Cardinality and Range | Description | Inheritance |
---|---|---|---|
normal_open | 1..1 Boolean |
The attribute is used in cases when no Measurement for the status value is pr... | Switch |
rated_current | 0..1 CurrentFlow |
The maximum continuous current carrying capacity in amps governed by the devi... | Switch |
retained | 1..1 Boolean |
Branch is retained in the topological solution | Switch |
base_voltage | 0..1 BaseVoltage |
Base voltage of this conducting equipment | ConductingEquipment |
terminals | 0..* Terminal |
Conducting equipment have terminals that may be connected to other conducting... | ConductingEquipment |
aggregate | 0..1 Boolean |
The aggregate flag provides an alternative way of representing an aggregated ... | Equipment |
normally_in_service | 0..1 Boolean |
Specifies the availability of the equipment under normal operating conditions | Equipment |
equipment_container | 0..1 EquipmentContainer |
Container of this equipment | Equipment |
description | 0..1 String |
The description is a free human readable text describing or naming the object | IdentifiedObject |
energy_ident_code_eic | 0..1 String |
The attribute is used for an exchange of the EIC code (Energy identification ... | IdentifiedObject |
m_rid | 1..1 String |
Master resource identifier issued by a model authority | IdentifiedObject |
short_name | 0..1 String |
The attribute is used for an exchange of a human readable short name with len... | IdentifiedObject |
names | 0..* Name |
All names of this identified object | IdentifiedObject |
Identifier and Mapping Information
Schema Source
- from schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
Mappings
Mapping Type | Mapped Value |
---|---|
self | cim:Disconnector |
native | this:Disconnector |
LinkML Source
Direct
name: Disconnector
description: A manually operated or motor operated mechanical switching device used
for changing the connections in a circuit, or for isolating a circuit or equipment
from a source of power. It is required to open or close circuits when negligible
current is broken or made.
from_schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
rank: 1000
is_a: Switch
class_uri: cim:Disconnector
Induced
name: Disconnector
description: A manually operated or motor operated mechanical switching device used
for changing the connections in a circuit, or for isolating a circuit or equipment
from a source of power. It is required to open or close circuits when negligible
current is broken or made.
from_schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
rank: 1000
is_a: Switch
attributes:
normal_open:
name: normal_open
description: The attribute is used in cases when no Measurement for the status
value is present. If the Switch has a status measurement the Discrete.normalValue
is expected to match with the Switch.normalOpen.
from_schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
rank: 1000
slot_uri: cim:Switch.normalOpen
multivalued: false
alias: normal_open
owner: Disconnector
domain_of:
- Switch
range: boolean
required: true
rated_current:
name: rated_current
description: 'The maximum continuous current carrying capacity in amps governed
by the device material and construction.
The attribute shall be a positive value.'
from_schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
rank: 1000
slot_uri: cim:Switch.ratedCurrent
multivalued: false
alias: rated_current
owner: Disconnector
domain_of:
- Switch
- BusbarSectionInfo
- WireInfo
range: CurrentFlow
required: false
retained:
name: retained
description: Branch is retained in the topological solution. The flow through
retained switches will normally be calculated in power flow.
from_schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
rank: 1000
slot_uri: cim:Switch.retained
multivalued: false
alias: retained
owner: Disconnector
domain_of:
- Switch
range: boolean
required: true
base_voltage:
name: base_voltage
description: Base voltage of this conducting equipment. Use only when there is
no voltage level container used and only one base voltage applies. For example,
not used for transformers.
from_schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
rank: 1000
slot_uri: cim:ConductingEquipment.BaseVoltage
multivalued: false
alias: base_voltage
owner: Disconnector
domain_of:
- ConductingEquipment
- VoltageLevel
- TransformerEnd
range: BaseVoltage
required: false
terminals:
name: terminals
description: Conducting equipment have terminals that may be connected to other
conducting equipment terminals via connectivity nodes or topological nodes.
from_schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
rank: 1000
slot_uri: cim:ConductingEquipment.Terminals
multivalued: true
alias: terminals
owner: Disconnector
domain_of:
- ConductingEquipment
- ConnectivityNode
range: Terminal
required: false
aggregate:
name: aggregate
description: "The aggregate flag provides an alternative way of representing an\
\ aggregated (equivalent) element. It is applicable in cases when the dedicated\
\ classes for equivalent equipment do not have all of the attributes necessary\
\ to represent the required level of detail. In case the flag is set to “true”\
\ the single instance of equipment represents multiple pieces of equipment that\
\ have been modelled together as an aggregate equivalent obtained by a network\
\ reduction procedure. Examples would be power transformers or synchronous machines\
\ operating in parallel modelled as a single aggregate power transformer or\
\ aggregate synchronous machine. \nThe attribute is not used for EquivalentBranch,\
\ EquivalentShunt and EquivalentInjection."
from_schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
rank: 1000
slot_uri: cim:Equipment.aggregate
multivalued: false
alias: aggregate
owner: Disconnector
domain_of:
- Equipment
range: boolean
required: false
normally_in_service:
name: normally_in_service
description: Specifies the availability of the equipment under normal operating
conditions. True means the equipment is available for topology processing, which
determines if the equipment is energized or not. False means that the equipment
is treated by network applications as if it is not in the model.
from_schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
rank: 1000
slot_uri: cim:Equipment.normallyInService
multivalued: false
alias: normally_in_service
owner: Disconnector
domain_of:
- Equipment
range: boolean
required: false
equipment_container:
name: equipment_container
description: Container of this equipment.
from_schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
rank: 1000
slot_uri: cim:Equipment.EquipmentContainer
multivalued: false
alias: equipment_container
owner: Disconnector
domain_of:
- Equipment
range: EquipmentContainer
required: false
description:
name: description
description: The description is a free human readable text describing or naming
the object. It may be non unique and may not correlate to a naming hierarchy.
from_schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
rank: 1000
slot_uri: cim:IdentifiedObject.description
multivalued: false
alias: description
owner: Disconnector
domain_of:
- IdentifiedObject
- NameType
- NameTypeAuthority
range: string
required: false
energy_ident_code_eic:
name: energy_ident_code_eic
description: The attribute is used for an exchange of the EIC code (Energy identification
Code). The length of the string is 16 characters as defined by the EIC code.
For details on EIC scheme please refer to ENTSO-E web site.
from_schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
rank: 1000
slot_uri: eu:IdentifiedObject.energyIdentCodeEic
multivalued: false
alias: energy_ident_code_eic
owner: Disconnector
domain_of:
- IdentifiedObject
range: string
required: false
m_rid:
name: m_rid
description: 'Master resource identifier issued by a model authority. The mRID
is unique within an exchange context. Global uniqueness is easily achieved by
using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly
recommended.
For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is
mapped to rdf:ID or rdf:about attributes that identify CIM object elements.'
from_schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
rank: 1000
slot_uri: cim:IdentifiedObject.mRID
multivalued: false
alias: m_rid
owner: Disconnector
domain_of:
- IdentifiedObject
range: string
required: true
short_name:
name: short_name
description: The attribute is used for an exchange of a human readable short name
with length of the string 12 characters maximum.
from_schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
rank: 1000
slot_uri: eu:IdentifiedObject.shortName
multivalued: false
alias: short_name
owner: Disconnector
domain_of:
- IdentifiedObject
range: string
required: false
names:
name: names
description: All names of this identified object.
from_schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
rank: 1000
slot_uri: cim:IdentifiedObject.Names
multivalued: true
alias: names
owner: Disconnector
domain_of:
- IdentifiedObject
- NameType
range: Name
required: false
class_uri: cim:Disconnector