Class: CurrentFlow
Electrical current with sign convention: positive flow is out of the conducting equipment into the connectivity node. Can be both AC and DC.
URI: cim:CurrentFlow
classDiagram
class CurrentFlow
CurrentFlow : CurrentFlow.multiplier
CurrentFlow --> UnitMultiplier : CurrentFlow.multiplier
CurrentFlow : CurrentFlow.unit
CurrentFlow --> UnitSymbol : CurrentFlow.unit
CurrentFlow : CurrentFlow.value
Slots
Name | Cardinality and Range | Description | Inheritance |
---|---|---|---|
value | 0..1 Float |
direct | |
multiplier | 0..1 UnitMultiplier |
direct | |
unit | 0..1 UnitSymbol |
direct |
Usages
used by | used in | type | used |
---|---|---|---|
Breaker | rated_current | range | CurrentFlow |
ProtectedSwitch | rated_current | range | CurrentFlow |
Switch | rated_current | range | CurrentFlow |
Disconnector | rated_current | range | CurrentFlow |
LoadBreakSwitch | rated_current | range | CurrentFlow |
BusbarSectionInfo | rated_current | range | CurrentFlow |
WireInfo | rated_current | range | CurrentFlow |
Identifier and Mapping Information
Schema Source
- from schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
Mappings
Mapping Type | Mapped Value |
---|---|
self | cim:CurrentFlow |
native | this:CurrentFlow |
LinkML Source
Direct
name: CurrentFlow
description: 'Electrical current with sign convention: positive flow is out of the
conducting equipment into the connectivity node. Can be both AC and DC.'
from_schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
rank: 1000
attributes:
value:
name: value
from_schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
slot_uri: cim:CurrentFlow.value
multivalued: false
domain_of:
- Susceptance
- Conductance
- Resistance
- Reactance
- Length
- Voltage
- CurrentFlow
- ActivePower
- PerCent
- ReactivePower
range: float
required: false
multiplier:
name: multiplier
from_schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
slot_uri: cim:CurrentFlow.multiplier
multivalued: false
domain_of:
- Susceptance
- Conductance
- Resistance
- Reactance
- Length
- Voltage
- CurrentFlow
- ActivePower
- PerCent
- ReactivePower
range: UnitMultiplier
required: false
unit:
name: unit
from_schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
slot_uri: cim:CurrentFlow.unit
multivalued: false
domain_of:
- Susceptance
- Conductance
- Resistance
- Reactance
- Length
- Voltage
- CurrentFlow
- ActivePower
- PerCent
- ReactivePower
range: UnitSymbol
required: false
class_uri: cim:CurrentFlow
Induced
name: CurrentFlow
description: 'Electrical current with sign convention: positive flow is out of the
conducting equipment into the connectivity node. Can be both AC and DC.'
from_schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
rank: 1000
attributes:
value:
name: value
from_schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
slot_uri: cim:CurrentFlow.value
multivalued: false
alias: value
owner: CurrentFlow
domain_of:
- Susceptance
- Conductance
- Resistance
- Reactance
- Length
- Voltage
- CurrentFlow
- ActivePower
- PerCent
- ReactivePower
range: float
required: false
multiplier:
name: multiplier
from_schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
slot_uri: cim:CurrentFlow.multiplier
multivalued: false
alias: multiplier
owner: CurrentFlow
domain_of:
- Susceptance
- Conductance
- Resistance
- Reactance
- Length
- Voltage
- CurrentFlow
- ActivePower
- PerCent
- ReactivePower
range: UnitMultiplier
required: false
unit:
name: unit
from_schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
slot_uri: cim:CurrentFlow.unit
multivalued: false
alias: unit
owner: CurrentFlow
domain_of:
- Susceptance
- Conductance
- Resistance
- Reactance
- Length
- Voltage
- CurrentFlow
- ActivePower
- PerCent
- ReactivePower
range: UnitSymbol
required: false
class_uri: cim:CurrentFlow