Class: ACDCTerminal
An electrical connection point (AC or DC) to a piece of conducting equipment. Terminals are connected at physical connection points called connectivity nodes.
URI: cim:ACDCTerminal
classDiagram
class ACDCTerminal
IdentifiedObject <|-- ACDCTerminal
ACDCTerminal <|-- Terminal
ACDCTerminal : IdentifiedObject.description
ACDCTerminal : IdentifiedObject.energyIdentCodeEic
ACDCTerminal : IdentifiedObject.mRID
ACDCTerminal : IdentifiedObject.Names
ACDCTerminal --> Name : IdentifiedObject.Names
ACDCTerminal : ACDCTerminal.sequenceNumber
ACDCTerminal : IdentifiedObject.shortName
Inheritance
- IdentifiedObject
- ACDCTerminal
Slots
Name | Cardinality and Range | Description | Inheritance |
---|---|---|---|
sequence_number | 1..1 Integer |
The orientation of the terminal connections for a multiple terminal conductin... | direct |
description | 0..1 String |
The description is a free human readable text describing or naming the object | IdentifiedObject |
energy_ident_code_eic | 0..1 String |
The attribute is used for an exchange of the EIC code (Energy identification ... | IdentifiedObject |
m_rid | 1..1 String |
Master resource identifier issued by a model authority | IdentifiedObject |
short_name | 0..1 String |
The attribute is used for an exchange of a human readable short name with len... | IdentifiedObject |
names | 0..* Name |
All names of this identified object | IdentifiedObject |
Identifier and Mapping Information
Schema Source
- from schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
Mappings
Mapping Type | Mapped Value |
---|---|
self | cim:ACDCTerminal |
native | this:ACDCTerminal |
LinkML Source
Direct
name: ACDCTerminal
description: An electrical connection point (AC or DC) to a piece of conducting equipment.
Terminals are connected at physical connection points called connectivity nodes.
from_schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
rank: 1000
is_a: IdentifiedObject
attributes:
sequence_number:
name: sequence_number
description: The orientation of the terminal connections for a multiple terminal
conducting equipment. The sequence numbering starts with 1 and additional terminals
should follow in increasing order. The first terminal is the "starting point"
for a two terminal branch.
from_schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
rank: 1000
slot_uri: cim:ACDCTerminal.sequenceNumber
multivalued: false
domain_of:
- ACDCTerminal
range: integer
required: true
class_uri: cim:ACDCTerminal
Induced
name: ACDCTerminal
description: An electrical connection point (AC or DC) to a piece of conducting equipment.
Terminals are connected at physical connection points called connectivity nodes.
from_schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
rank: 1000
is_a: IdentifiedObject
attributes:
sequence_number:
name: sequence_number
description: The orientation of the terminal connections for a multiple terminal
conducting equipment. The sequence numbering starts with 1 and additional terminals
should follow in increasing order. The first terminal is the "starting point"
for a two terminal branch.
from_schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
rank: 1000
slot_uri: cim:ACDCTerminal.sequenceNumber
multivalued: false
alias: sequence_number
owner: ACDCTerminal
domain_of:
- ACDCTerminal
range: integer
required: true
description:
name: description
description: The description is a free human readable text describing or naming
the object. It may be non unique and may not correlate to a naming hierarchy.
from_schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
rank: 1000
slot_uri: cim:IdentifiedObject.description
multivalued: false
alias: description
owner: ACDCTerminal
domain_of:
- IdentifiedObject
- NameType
- NameTypeAuthority
range: string
required: false
energy_ident_code_eic:
name: energy_ident_code_eic
description: The attribute is used for an exchange of the EIC code (Energy identification
Code). The length of the string is 16 characters as defined by the EIC code.
For details on EIC scheme please refer to ENTSO-E web site.
from_schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
rank: 1000
slot_uri: eu:IdentifiedObject.energyIdentCodeEic
multivalued: false
alias: energy_ident_code_eic
owner: ACDCTerminal
domain_of:
- IdentifiedObject
range: string
required: false
m_rid:
name: m_rid
description: 'Master resource identifier issued by a model authority. The mRID
is unique within an exchange context. Global uniqueness is easily achieved by
using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly
recommended.
For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is
mapped to rdf:ID or rdf:about attributes that identify CIM object elements.'
from_schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
rank: 1000
slot_uri: cim:IdentifiedObject.mRID
multivalued: false
alias: m_rid
owner: ACDCTerminal
domain_of:
- IdentifiedObject
range: string
required: true
short_name:
name: short_name
description: The attribute is used for an exchange of a human readable short name
with length of the string 12 characters maximum.
from_schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
rank: 1000
slot_uri: eu:IdentifiedObject.shortName
multivalued: false
alias: short_name
owner: ACDCTerminal
domain_of:
- IdentifiedObject
range: string
required: false
names:
name: names
description: All names of this identified object.
from_schema: http://iec.ch/TC57/ns/CIM/CoreEquipment-EU#Package_CoreEquipmentProfile
rank: 1000
slot_uri: cim:IdentifiedObject.Names
multivalued: true
alias: names
owner: ACDCTerminal
domain_of:
- IdentifiedObject
- NameType
range: Name
required: false
class_uri: cim:ACDCTerminal