Skip to content

Slot: value

URI: cim:value

Applicable Classes

Name Description Modifies Slot
CostRate Cost, in units of currency, per elapsed time no
PumpingCostSchedule The operating cost of a Pump Storage Hydro Unit operating as a hydro pump no
Area Area no
ScheduledVoltageLimitValue A voltage limit value for a scheduled time no
PerCent Percentage on a defined base no
Minutes Time in minutes no
ApparentPowerLimit Apparent power limit no
HealthScore Score that is indicative of the health of one or more assets no
Frequency Cycles per second no
UserAttribute Generic name-value pair class, with optional sequence number and units for va... no
Admittance Ratio of current to voltage no
CommodityPrice The CommodityPrice class is used to define the price of a commodity during a ... no
Money Amount of money no
MeterMultiplier Multiplier applied at the meter no
BaseReading Common representation for reading values no
MktUserAttribute Subclass of IEC61968:Domain2:UserAttribute no
Command A Command is a discrete control used for supervisory control no
IntegerQuantity Quantity with integer value and associated unit information no
EndDeviceEventDetail Name-value pair, specific to end device events no
CapacitancePerLength Capacitance per unit of length no
Temperature Value of temperature in degrees Celsius no
ActivePowerPerFrequency Active power variation with frequency no
WheelingReferenceSchedule A unique identifier of a wheeling transaction no
Pressure Pressure in pascals no
ActivePowerPerCurrentFlow Active power variation with current flow no
DecimalQuantity Quantity with decimal value and associated unit or currency information no
CurrentLimit Operational limit on current no
StringMeasurementValue StringMeasurementValue represents a measurement value of type string no
ValueToAlias Describes the translation of one particular value into a name, e no
SetPoint An analog control that issues a set point value no
Damping Per-unit active power variation with frequency referenced on the system appar... no
CostPerHeatUnit Cost, in units of currency, per quantity of heat generated no
MagneticField Magnetic field in nanotesla no
Volume Volume no
ReactancePerLength Reactance (imaginary part of impedance) per unit of length, at rated frequenc... no
AccumulatorValue AccumulatorValue represents an accumulated (counted) MeasurementValue no
FloatQuantity Quantity with float value and associated unit information no
ScheduledCurrentLimitValue A current limit that is scheduled no
ConductancePerLength Real part of admittance per unit of length no
MktAnalogLimit Subclass of IEC 61970:Meas:AnalogLimit no
RealEnergy Real electrical energy no
AngleDegrees Measurement of angle in degrees no
HeatRate Heat generated, in energy per time unit of elapsed time no
Reading Specific value measured by a meter or other asset, or calculated by a system no
RiskScore Score that is indicative of the risk associated with one or more assets no
CostPerVolume Cost per unit volume no
AggregateScore An aggregated indicative scoring by an analytic, which is based on other anal... no
PU Per Unit - a positive or negative value referred to a defined base no
IrregularTimePoint TimePoints for a schedule where the time between the points varies no
ActivePowerLimit Limit on active power flow no
KiloActivePower Active power in kilowatts no
ApparentPower Product of the RMS value of the voltage and the RMS value of the current no
CostPerEnergyUnit Cost, in units of currency, per quantity of electrical energy generated no
Reactance Reactance (imaginary part of impedance), at rated frequency no
IntervalReading Data captured at regular intervals of time no
Voltage Electrical voltage, can be both AC and DC no
HourlyPreDispatchSchedule An indicator specifying that a resource shall have an Hourly Pre-Dispatch no
ReactivePower Product of RMS value of the voltage and the RMS value of the quadrature compo... no
ScheduledActivePowerLimitValue no
AngleRadians Phase angle in radians no
Susceptance Imaginary part of admittance no
RegularTimePoint Time point for a schedule where the time between the consecutive points is co... no
Resistance Resistance (real part of impedance) no
ScheduledApparentPowerLimitValue A time scheduled value for apparent power limit no
ResistancePerLength Resistance (real part of impedance) per unit of length no
VoltagePerReactivePower Voltage variation with reactive power no
ServiceMultiplier Multiplier applied at the usage point no
PumpingLevelSchedule The fixed operating level of a Pump Storage Hydro Unit operating as a hydro p... no
Displacement Unit of displacement relative to a reference position, hence can be negative no
AnalogLimit Limit values for Analog measurements no
ActivePowerChangeRate Rate of change of active power per time no
SusceptancePerLength Imaginary part of admittance per unit of length no
Seconds Time, in seconds no
Hours Time specified in hours no
Classification Classification of level no
Capacitance Capacitive part of reactance (imaginary part of impedance), at rated frequenc... no
InductancePerLength Inductance per unit of length no
Inductance Inductive part of reactance (imaginary part of impedance), at rated frequency no
Bearing The bearing in degrees (with 360 degrees being True North) no
AccountingUnit Unit for accounting; use either 'energyUnit' or 'currencyUnit' to specify the... no
Conductance Factor by which voltage must be multiplied to give corresponding power lost f... no
ActivePower Product of RMS value of the voltage and the RMS value of the in-phase compone... no
AccumulatorLimit Limit values for Accumulator measurements no
Length Unit of length no
ParticulateDensity Particulate density as kg/m3 no
EnvironmentalCodedValue An environmental value described using a coded value no
OpenTieSchedule Result of bid validation against conditions that may exist on an interchange ... no
Impedance Ratio of voltage to current no
AnalyticScore An indicative scoring by an analytic that can be used to characterize the hea... no
Mass Mass no
Status Current status information relevant to an entity no
WaterLevel Reservoir water level referred to a given datum such as mean sea level no
VolumeFlowRate Volume per time no
CurrentFlow Electrical current with sign convention: positive flow is out of the conducti... no
RotationSpeed Number of revolutions per second no
PumpingShutDownCostSchedule The cost to shutdown a Pump Storage Hydro Unit (in pump mode) or a pump no
StringQuantity Quantity with string value (when it is not important whether it is an integra... no
Speed Distance per unit of time no
DiscreteValue DiscreteValue represents a discrete MeasurementValue no
ChargeProfileData Model of various charges associated with an energy profile to support billing... no
VoltageLimit Operational limit applied to voltage no
AnalogValue AnalogValue represents an analog MeasurementValue no
Emission Quantity of emission per fuel heat content no

Properties

Identifier and Mapping Information

LinkML Source

name: value
alias: value
domain_of:
- VoltagePerReactivePower
- Length
- ConductancePerLength
- VolumeFlowRate
- Volume
- Voltage
- Temperature
- Admittance
- Impedance
- CostPerVolume
- SusceptancePerLength
- Money
- Minutes
- FloatQuantity
- CostPerEnergyUnit
- PerCent
- IntegerQuantity
- ApparentPower
- WaterLevel
- Displacement
- Damping
- Seconds
- ResistancePerLength
- Inductance
- AngleDegrees
- CostRate
- Speed
- Capacitance
- PU
- Pressure
- KiloActivePower
- ReactivePower
- StringQuantity
- ActivePowerChangeRate
- Hours
- Conductance
- RotationSpeed
- CurrentFlow
- Frequency
- AngleRadians
- ActivePower
- ReactancePerLength
- Resistance
- Reactance
- Susceptance
- RealEnergy
- Classification
- HeatRate
- Emission
- CostPerHeatUnit
- ActivePowerPerFrequency
- InductancePerLength
- CapacitancePerLength
- DecimalQuantity
- Area
- ActivePowerPerCurrentFlow
- Mass
- Status
- UserAttribute
- AccountingUnit
- BaseReading
- EndDeviceEventDetail
- MeterMultiplier
- RegularTimePoint
- AnalogValue
- AnalogLimit
- CommodityPrice
- ChargeProfileData
- StringMeasurementValue
- Command
- DiscreteValue
- ValueToAlias
- ServiceMultiplier
- AnalyticScore
- IrregularTimePoint
- ActivePowerLimit
- ApparentPowerLimit
- CurrentLimit
- VoltageLimit
- AccumulatorValue
- AccumulatorLimit
- SetPoint
- ScheduledActivePowerLimitValue
- ScheduledApparentPowerLimitValue
- ScheduledCurrentLimitValue
- ScheduledVoltageLimitValue
- MagneticField
- ParticulateDensity
- Bearing
- PumpingShutDownCostSchedule
- PumpingLevelSchedule
- HourlyPreDispatchSchedule
- PumpingCostSchedule
- OpenTieSchedule
- WheelingReferenceSchedule
range: string