Slot: site_multiplier
This value provides for scaling of a response method's active power. For example, a response method of air conditioning could utilize a small amount of active power from each air conditioning unit (e.g. 0.1 kiloWatt), but the site multiplier could be used to produce a the total active power adjustment by multiplying the response method active power by this value (e.g. a building with 100 window air conditioning units, so 100 * 0.1 kW = 10 kW).
URI: cim:ResponseMethod.siteMultiplier
Applicable Classes
| Name | Description | Modifies Slot |
|---|---|---|
| ResponseMethod | Specifies a category of energy usage that the demand response applies for; e | no |
Properties
- Range: Integer
Identifier and Mapping Information
Schema Source
- from schema: https://cim.ucaiug.io/ns#TC57CIM
LinkML Source
name: site_multiplier
description: This value provides for scaling of a response method's active power.
For example, a response method of air conditioning could utilize a small amount
of active power from each air conditioning unit (e.g. 0.1 kiloWatt), but the site
multiplier could be used to produce a the total active power adjustment by multiplying
the response method active power by this value (e.g. a building with 100 window
air conditioning units, so 100 * 0.1 kW = 10 kW).
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ResponseMethod.siteMultiplier
multivalued: false
alias: site_multiplier
owner: ResponseMethod
domain_of:
- ResponseMethod
range: integer
required: false