Skip to content

Slot: grounding_action

Action involving grounding operation on this conducting equipment.

URI: cim:ConductingEquipment.GroundingAction

Applicable Classes

Name Description Modifies Slot
EquivalentInjection This class represents equivalent injections (generation or load) no
Sectionaliser Automatic switch that will lock open to isolate a faulted section no
NonConformLoad NonConformLoad represents loads that do not follow a daily load change patter... no
Fuse An overcurrent protective device with a circuit opening fusible part that is ... no
EquivalentBranch The class represents equivalent branches no
EquivalentEquipment The class represents equivalent objects that are the result of a network redu... no
PetersenCoil A variable impedance device normally used to offset line charging during sing... no
PowerTransformer An electrical device consisting of two or more coupled windings, with or wit... no
PowerElectronicsConnection A connection to the AC network for energy production or consumption that uses... no
MktACLineSegment Subclass of IEC 61970:Wires:ACLineSegment no
AsynchronousMachine A rotating machine whose shaft rotates asynchronously with the electrical fie... no
NonlinearShuntCompensator A non linear shunt compensator has bank or section admittance values that dif... no
ConductingEquipment The parts of the AC power system that are designed to carry current or that a... no
Clamp A Clamp is a galvanic connection at a line segment where other equipment is c... no
CsConverter DC side of the current source converter (CSC) no
Cut A cut separates a line segment into two parts no
GroundDisconnector A manually operated or motor operated mechanical switching device used for is... no
MktShuntCompensator Subclass of IEC 61970:Wires:ShuntCompensator no
Ground A point where the system is grounded used for connecting conducting equipment... no
EnergyConsumer Generic user of energy - a point of consumption on the power system model no
VsConverter DC side of the voltage source converter (VSC) no
ProtectedSwitch A ProtectedSwitch is a switching device that can be operated by ProtectionEqu... no
ConformLoad ConformLoad represent loads that follow a daily load change pattern where the... no
LoadBreakSwitch A mechanical switching device capable of making, carrying, and breaking curre... no
ShuntCompensator A shunt capacitor or reactor or switchable bank of shunt capacitors or reacto... no
MktPowerTransformer Subclass of IEC61970:Wires:PowerTransformer no
EarthFaultCompensator A conducting equipment used to represent a connection to ground which is typi... no
RotatingMachine A rotating machine which may be used as a generator or motor no
SynchronousMachine An electromechanical device that operates with shaft rotating synchronously w... no
MktConductingEquipment Subclass of IEC 61970:Core:ConductingEquipment no
Junction A point where one or more conducting equipments are connected with zero resis... no
DisconnectingCircuitBreaker A circuit breaking device including disconnecting function, eliminating the n... no
WireSegment A two terminal and power conducting device of negligible impedance and length... no
EnergyConnection A connection of energy generation or consumption on the power system model no
MktSwitch Subclass of IEC 61970:Wires:Switch no
ACLineSegment A wire or combination of wires, with consistent electrical characteristics, b... no
Disconnector A manually operated or motor operated mechanical switching device used for ch... no
SeriesCompensator A Series Compensator is a series capacitor or reactor or an AC transmission l... no
Breaker A mechanical switching device capable of making, carrying, and breaking curre... no
StaticVarCompensator A facility for providing variable and controllable shunt reactive power no
SVC SVC asset allows the capacitive and inductive ratings for each phase to be sp... no
GroundingImpedance A fixed impedance device used for grounding no
ExternalNetworkInjection This class represents the external network and it is used for IEC 60909 calcu... no
Connector A conductor, or group of conductors, with negligible impedance, that serve to... no
ACDCConverter A unit with valves for three phases, together with unit control equipment, es... no
FrequencyConverter A device to convert from one frequency to another (e no
BusbarSection A conductor, or group of conductors, with negligible impedance, that serve to... no
StationSupply Station supply with load derived from the station output no
Conductor Combination of conducting material with consistent electrical characteristics... no
Recloser Pole-mounted fault interrupter with built-in phase and ground relays, current... no
RegulatingCondEq A type of conducting equipment that can regulate a quantity (i no
LinearShuntCompensator A linear shunt compensator has banks or sections with equal admittance values no
EquivalentShunt The class represents equivalent shunts no
EnergySource A generic equivalent for an energy supplier on a transmission or distribution... no
Jumper A short section of conductor with negligible impedance which can be manually ... no
Switch A generic device designed to close, or open, or both, one or more electric ci... no
MktSeriesCompensator Subclass of IEC 61970:Wires:SeriesCompensator no

Properties

Identifier and Mapping Information

Schema Source

  • from schema: https://cim.ucaiug.io/ns#TC57CIM

LinkML Source

name: grounding_action
description: Action involving grounding operation on this conducting equipment.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ConductingEquipment.GroundingAction
multivalued: false
alias: grounding_action
owner: ConductingEquipment
domain_of:
- ConductingEquipment
range: GroundAction
required: false