| DCLine |
Overhead lines and/or cables connecting two or more HVDC substations |
no |
| EquipmentContainer |
A modelling construct to provide a root class for containing equipment |
no |
| PostLineSensor |
A sensor used mainly in overhead distribution networks as the source of both... |
no |
| DCConductingEquipment |
The parts of the DC power system that are designed to carry current or that a... |
no |
| RegisteredLoad |
Model of a load that is registered to participate in the market |
no |
| Substation |
A collection of equipment for purposes other than generation or utilization, ... |
no |
| Subcritical |
Once-through subcritical boiler |
no |
| AsynchronousMachine |
A rotating machine whose shaft rotates asynchronously with the electrical fie... |
no |
| NonlinearShuntCompensator |
A non linear shunt compensator has bank or section admittance values that dif... |
no |
| DCDisconnector |
A disconnector within a DC system |
no |
| DCSwitch |
A switch within the DC system |
no |
| CsConverter |
DC side of the current source converter (CSC) |
no |
| MktCombinedCyclePlant |
Subclass of Production: CombinedCyclePlant from IEC 61970 package |
no |
| EnergyConsumer |
Generic user of energy - a point of consumption on the power system model |
no |
| VsConverter |
DC side of the voltage source converter (VSC) |
no |
| PowerSystemResource |
A power system resource (PSR) can be an item of equipment such as a switch, a... |
no |
| ConformLoad |
ConformLoad represent loads that follow a daily load change pattern where the... |
no |
| LoadBreakSwitch |
A mechanical switching device capable of making, carrying, and breaking curre... |
no |
| EarthFaultCompensator |
A conducting equipment used to represent a connection to ground which is typi... |
no |
| RemoteUnit |
A remote unit can be an RTU, IED, substation control system, control centre, ... |
no |
| HydroPump |
A synchronous motor-driven pump, typically associated with a pumped storage p... |
no |
| RegisteredResource |
A resource that is registered through the market participant registration sys... |
no |
| HydroPowerPlant |
A hydro power station which can generate or pump |
no |
| Circuit |
|
no |
| SolarGeneratingUnit |
A solar thermal generating unit, connected to the grid by means of a rotating... |
no |
| Equipment |
The parts of a power system that are physical devices, electronic or mechanic... |
no |
| PhaseTapChangerLinear |
Describes a tap changer with a linear relation between the tap step and the p... |
no |
| DCGround |
A ground within a DC system |
no |
| FossilSteamSupply |
Fossil fuelled boiler (e |
no |
| HeatRecoveryBoiler |
The heat recovery system associated with combustion turbines in order to prod... |
no |
| TapChanger |
Mechanism for changing transformer winding tap positions |
no |
| ISOUpperLayer |
Is a set of configure addressing information that is required since ICCP util... |
no |
| Breaker |
A mechanical switching device capable of making, carrying, and breaking curre... |
no |
| ThermalGeneratingUnit |
A generating unit whose prime mover could be a steam turbine, combustion turb... |
no |
| GroundingImpedance |
A fixed impedance device used for grounding |
no |
| ExternalNetworkInjection |
This class represents the external network and it is used for IEC 60909 calcu... |
no |
| BatteryUnit |
An electrochemical energy storage device |
no |
| MktGeneratingUnit |
Subclass of IEC61970:Production:GeneratingUnit |
no |
| SteamSupply |
Steam supply for steam turbine |
no |
| BusbarSection |
A conductor, or group of conductors, with negligible impedance, that serve to... |
no |
| StationSupply |
Station supply with load derived from the station output |
no |
| RegisteredDistributedResource |
A registered resource that represents a distributed energy resource, such as ... |
no |
| MktLine |
Subclass for IEC61970:Wires:Line |
no |
| RegulatingCondEq |
A type of conducting equipment that can regulate a quantity (i |
no |
| Jumper |
A short section of conductor with negligible impedance which can be manually ... |
no |
| CurrentTransformer |
Instrument transformer used to measure electrical qualities of the circuit th... |
no |
| Switch |
A generic device designed to close, or open, or both, one or more electric ci... |
no |
| PhaseTapChangerSymmetrical |
Describes a symmetrical phase shifting transformer tap model in which the vol... |
no |
| PhaseTapChangerNonLinear |
The non-linear phase tap changer describes the non-linear behaviour of a phas... |
no |
| PetersenCoil |
A variable impedance device normally used to offset line charging during sing... |
no |
| PowerTransformer |
An electrical device consisting of two or more coupled windings, with or wit... |
no |
| IPAccessPoint |
Internet Protocol Access Point – used to represent an addressing structure is... |
no |
| PhaseTapChangerAsymmetrical |
Describes the tap model for an asymmetrical phase shifting transformer in whi... |
no |
| Cut |
A cut separates a line segment into two parts |
no |
| TapChangerControl |
Describes behaviour specific to tap changers, e |
no |
| PowerElectronicsConnectionPhase |
A single phase of a power electronics connection |
no |
| RegulatingControl |
Specifies a set of equipment that works together to control a power system qu... |
no |
| ProtectedSwitch |
A ProtectedSwitch is a switching device that can be operated by ProtectionEqu... |
no |
| PhotoVoltaicUnit |
A photovoltaic device or an aggregation of such devices |
no |
| MktPowerTransformer |
Subclass of IEC61970:Wires:PowerTransformer |
no |
| Line |
Contains equipment beyond a substation belonging to a power transmission line |
no |
| GeneratingUnit |
A single or set of synchronous machines for converting mechanical power into ... |
no |
| PowerElectronicsWindUnit |
A wind generating unit that connects to the AC network with power electronics... |
no |
| RatioTapChanger |
A tap changer that changes the voltage ratio impacting the voltage magnitude ... |
no |
| DCConverterUnit |
Indivisible operative unit comprising all equipment between the point of comm... |
no |
| PowerCutZone |
An area or zone of the power system which is used for load shedding purposes |
no |
| ShuntCompensatorControl |
Distribution capacitor bank control settings |
no |
| SVC |
SVC asset allows the capacitive and inductive ratings for each phase to be sp... |
no |
| DCLineSegment |
A wire or combination of wires not insulated from one another, with consisten... |
no |
| EnergyGroup |
|
no |
| EquivalentNetwork |
A class that groups electrical equivalents, including internal nodes, of a ne... |
no |
| AuxiliaryEquipment |
AuxiliaryEquipment describe equipment that is not performing any primary func... |
no |
| Connector |
A conductor, or group of conductors, with negligible impedance, that serve to... |
no |
| ACDCConverter |
A unit with valves for three phases, together with unit control equipment, es... |
no |
| VoltageLevel |
A collection of equipment at one common system voltage forming a switchgear |
no |
| Feeder |
A collection of equipment for organizational purposes, used for grouping dist... |
no |
| CombinedCyclePlant |
A set of combustion turbines and steam turbines where the exhaust heat from t... |
no |
| FrequencyConverter |
A device to convert from one frequency to another (e |
no |
| WaveTrap |
Line traps are devices that impede high frequency power line carrier signals ... |
no |
| DrumBoiler |
Drum boiler |
no |
| CurrentRelay |
A device that checks current flow values in any direction or designated direc... |
no |
| MktShuntCompensator |
Subclass of IEC 61970:Wires:ShuntCompensator |
no |
| NonConformLoad |
NonConformLoad represents loads that do not follow a daily load change patter... |
no |
| HydroGeneratingUnit |
A generating unit whose prime mover is a hydraulic turbine (e |
no |
| CombinedCycleConfiguration |
Configuration options for combined cycle units |
no |
| Fuse |
An overcurrent protective device with a circuit opening fusible part that is ... |
no |
| TransmissionRightOfWay |
A collection of transmission lines that are close proximity to each other |
no |
| WeatherStation |
This represents a source of ambient temperature |
no |
| MktACLineSegment |
Subclass of IEC 61970:Wires:ACLineSegment |
no |
| RemedialActionScheme |
Remedial Action Scheme (RAS), Special Protection Schemes (SPS), System Protec... |
no |
| PhaseTapChangerTabular |
Describes a tap changer with a table defining the relation between the tap st... |
no |
| GroundDisconnector |
A manually operated or motor operated mechanical switching device used for is... |
no |
| NuclearGeneratingUnit |
A nuclear generating unit |
no |
| ControlArea |
A control area is a grouping of generating units and/or loads and a cutset of... |
no |
| DCChopper |
Low resistance equipment used in the internal DC circuit to balance voltages |
no |
| Reservoir |
A water storage facility within a hydro system, including: ponds, lakes, lago... |
no |
| ProtectionEquipment |
An electrical device designed to respond to input conditions in a prescribed ... |
no |
| RegisteredInterTie |
This class represents the inter tie resource |
no |
| EnergyConsumerPhase |
A single phase of an energy consumer |
no |
| SynchronousMachine |
An electromechanical device that operates with shaft rotating synchronously w... |
no |
| MktConductingEquipment |
Subclass of IEC 61970:Core:ConductingEquipment |
no |
| DisconnectingCircuitBreaker |
A circuit breaking device including disconnecting function, eliminating the n... |
no |
| WireSegment |
A two terminal and power conducting device of negligible impedance and length... |
no |
| ACLineSegmentPhase |
Represents a single wire of an alternating current line segment |
no |
| DCEquipmentContainer |
A modelling construct to provide a root class for containment of DC as well a... |
no |
| ACLineSegment |
A wire or combination of wires, with consistent electrical characteristics, b... |
no |
| VoltageControlZone |
An area of the power system network which is defined for secondary voltage co... |
no |
| RegisteredGenerator |
Model of a generator that is registered to participate in the market |
no |
| SteamTurbine |
Steam turbine |
no |
| AirCompressor |
Combustion turbine air compressor which is an integral part of a compressed a... |
no |
| CombustionTurbine |
A prime mover that is typically fuelled by gas or light oil |
no |
| SurgeArrester |
Shunt device, installed on the network, usually in the proximity of electrica... |
no |
| PWRSteamSupply |
Pressurized water reactor used as a steam supply to a steam turbine |
no |
| Plant |
A Plant is a collection of equipment for purposes of generation |
no |
| Recloser |
Pole-mounted fault interrupter with built-in phase and ground relays, current... |
no |
| PotentialTransformer |
Instrument transformer (also known as Voltage Transformer) used to measure el... |
no |
| EnergySource |
A generic equivalent for an energy supplier on a transmission or distribution... |
no |
| TransmissionCorridor |
A corridor containing one or more rights of way |
|
| no |
|
|
| MktTapChanger |
Subclass of IEC 61970:Wires:TapChanger |
no |
| WireSegmentPhase |
Represents a single wire of an alternating current wire segment |
no |
| DCBreaker |
A breaker within a DC system |
no |
| ConnectivityNodeContainer |
A base class for all objects that may contain connectivity nodes or topologic... |
no |
| EquivalentInjection |
This class represents equivalent injections (generation or load) |
no |
| MktControlArea |
Market subclass of IEC 61970:ControlArea |
no |
| CommunicationLink |
The connection to remote units is through one or more communication links |
no |
| CompositeSwitch |
A model of a set of individual Switches normally enclosed within the same cab... |
no |
| EquivalentBranch |
The class represents equivalent branches |
no |
| EquivalentEquipment |
The class represents equivalent objects that are the result of a network redu... |
no |
| HydroTurbine |
A water driven prime mover |
no |
| PowerElectronicsConnection |
A connection to the AC network for energy production or consumption that uses... |
no |
| PrimeMover |
The machine used to develop mechanical energy used to drive a generator |
no |
| PhaseTapChanger |
A transformer phase shifting tap model that controls the phase angle differen... |
no |
| CAESPlant |
Compressed air energy storage plant |
no |
| ConductingEquipment |
The parts of the AC power system that are designed to carry current or that a... |
no |
| Clamp |
A Clamp is a galvanic connection at a line segment where other equipment is c... |
no |
| CogenerationPlant |
A set of thermal generating units for the production of electrical energy and... |
no |
| WindGeneratingUnit |
A wind driven generating unit, connected to the grid by means of a rotating m... |
no |
| Ground |
A point where the system is grounded used for connecting conducting equipment... |
no |
| ShuntCompensator |
A shunt capacitor or reactor or switchable bank of shunt capacitors or reacto... |
no |
| RotatingMachine |
A rotating machine which may be used as a generator or motor |
no |
| ShuntCompensatorPhase |
Single phase of a multi-phase shunt compensator when its attributes might be ... |
no |
| DCShunt |
A shunt device within the DC system, typically used for filtering |
no |
| MktThermalGeneratingUnit |
Subclass of ThermalGeneratingUnit from Production Package in IEC 61970 |
no |
| Junction |
A point where one or more conducting equipments are connected with zero resis... |
no |
| SynchrocheckRelay |
A device that operates when two AC circuits are within the desired limits of ... |
no |
| EnergyConnection |
A connection of energy generation or consumption on the power system model |
no |
| LinearShuntCompensatorPhase |
A per phase linear shunt compensator has banks or sections with equal admitta... |
no |
| SwitchPhase |
Single phase of a multi-phase switch when its attributes might be different p... |
no |
| EnergySourcePhase |
Represents the single phase information of an unbalanced energy source |
no |
| HostControlArea |
A HostControlArea has a set of tie points and a set of generator controls (i |
no |
| Disconnector |
A manually operated or motor operated mechanical switching device used for ch... |
no |
| NonlinearShuntCompensatorPhase |
A per phase non linear shunt compensator has bank or section admittance value... |
no |
| MktSwitch |
Subclass of IEC 61970:Wires:Switch |
no |
| SeriesCompensator |
A Series Compensator is a series capacitor or reactor or an AC transmission l... |
no |
| StaticVarCompensator |
A facility for providing variable and controllable shunt reactive power |
no |
| Flowgate |
A flowgate, is single or group of transmission elements intended to model MW ... |
no |
| FaultIndicator |
A FaultIndicator is typically only an indicator (which may or may not be remo... |
no |
| BWRSteamSupply |
Boiling water reactor used as a steam supply to a steam turbine |
no |
| Supercritical |
Once-through supercritical boiler |
no |
| Sensor |
This class describe devices that transform a measured quantity into signals t... |
no |
| SubControlArea |
An area defined for the purpose of tracking interchange with surrounding area... |
no |
| FaultCauseType |
Type of cause of the fault |
no |
| TCPAccessPoint |
Allows addressing and behavioural information regarding the use of TCP by ICC... |
no |
| TransformerTank |
An assembly of two or more coupled windings that transform electrical power b... |
no |
| Bay |
A collection of power system resources (within a given substation) including ... |
no |
| Conductor |
Combination of conducting material with consistent electrical characteristics... |
no |
| LinearShuntCompensator |
A linear shunt compensator has banks or sections with equal admittance values |
no |
| EquivalentShunt |
The class represents equivalent shunts |
no |
| DCBusbar |
A busbar within a DC system |
no |
| DCSeriesDevice |
A series device within the DC system, typically a reactor used for filtering ... |
no |
| Sectionaliser |
Automatic switch that will lock open to isolate a faulted section |
no |
| MktSeriesCompensator |
Subclass of IEC 61970:Wires:SeriesCompensator |
no |
| PowerElectronicsUnit |
A generating unit or battery or aggregation that connects to the AC network u... |
no |