Class: WindContPType3IEC
_P control model type 3. _
Reference: IEC 61400-27-1:2015, 5.6.5.4.
classDiagram
class WindContPType3IEC
IdentifiedObject <|-- WindContPType3IEC
WindContPType3IEC : alias_name
WindContPType3IEC : description
WindContPType3IEC : diagram_objects
WindContPType3IEC --> DiagramObject : diagram_objects
WindContPType3IEC : dpmax
WindContPType3IEC --> PU : dpmax
WindContPType3IEC : dprefmax
WindContPType3IEC --> PU : dprefmax
WindContPType3IEC : dprefmin
WindContPType3IEC --> PU : dprefmin
WindContPType3IEC : dthetamax
WindContPType3IEC --> PU : dthetamax
WindContPType3IEC : dthetamaxuvrt
WindContPType3IEC --> PU : dthetamaxuvrt
WindContPType3IEC : instance_set
WindContPType3IEC --> InstanceSet : instance_set
WindContPType3IEC : kdtd
WindContPType3IEC --> PU : kdtd
WindContPType3IEC : kip
WindContPType3IEC --> PU : kip
WindContPType3IEC : kpp
WindContPType3IEC --> PU : kpp
WindContPType3IEC : m_rid
WindContPType3IEC : mpuvrt
WindContPType3IEC : names
WindContPType3IEC --> Name : names
WindContPType3IEC : omegadtd
WindContPType3IEC --> PU : omegadtd
WindContPType3IEC : omegaoffset
WindContPType3IEC --> PU : omegaoffset
WindContPType3IEC : pdtdmax
WindContPType3IEC --> PU : pdtdmax
WindContPType3IEC : properties_cimdata_object
WindContPType3IEC --> ChangeSetMember : properties_cimdata_object
WindContPType3IEC : targeting_cimdata_object
WindContPType3IEC --> ChangeSetMember : targeting_cimdata_object
WindContPType3IEC : tdvs
WindContPType3IEC --> Seconds : tdvs
WindContPType3IEC : thetaemin
WindContPType3IEC --> PU : thetaemin
WindContPType3IEC : thetauscale
WindContPType3IEC --> PU : thetauscale
WindContPType3IEC : tomegafiltp
WindContPType3IEC --> Seconds : tomegafiltp
WindContPType3IEC : tomegaref
WindContPType3IEC --> Seconds : tomegaref
WindContPType3IEC : tpfiltp
WindContPType3IEC --> Seconds : tpfiltp
WindContPType3IEC : tpord
WindContPType3IEC --> PU : tpord
WindContPType3IEC : tufiltp
WindContPType3IEC --> Seconds : tufiltp
WindContPType3IEC : udvs
WindContPType3IEC --> PU : udvs
WindContPType3IEC : updip
WindContPType3IEC --> PU : updip
WindContPType3IEC : wind_dynamics_lookup_table
WindContPType3IEC --> WindDynamicsLookupTable : wind_dynamics_lookup_table
WindContPType3IEC : wind_turbine_type_iec
WindContPType3IEC --> WindTurbineType3IEC : wind_turbine_type_iec
WindContPType3IEC : zeta
Inheritance
- IdentifiedObject
- WindContPType3IEC
Slots
| Name | Cardinality and Range | Description | Inheritance |
|---|---|---|---|
| dpmax | 0..1 PU |
Maximum wind turbine power ramp rate (dpmax) | direct |
| dprefmax | 0..1 PU |
Maximum ramp rate of wind turbine reference power (dprefmax</s... | direct |
| dprefmin | 0..1 PU |
Minimum ramp rate of wind turbine reference power (dprefmin</s... | direct |
| dthetamax | 0..1 PU |
Ramp limitation of torque, required in some grid codes (dtmax<... | direct |
| dthetamaxuvrt | 0..1 PU |
Limitation of torque rise rate during UVRT (dthetamaxUVRT</sub... | direct |
| kdtd | 0..1 PU |
Gain for active drive train damping (KDTD) | direct |
| kip | 0..1 PU |
PI controller integration parameter (KIp) | direct |
| kpp | 0..1 PU |
PI controller proportional gain (KPp) | direct |
| mpuvrt | 0..1 Boolean |
Enable UVRT power control mode (MpUVRT) | direct |
| omegadtd | 0..1 PU |
Active drive train damping frequency (omegaDTD) | direct |
| omegaoffset | 0..1 PU |
Offset to reference value that limits controller action during rotor speed ch... | direct |
| pdtdmax | 0..1 PU |
Maximum active drive train damping power (pDTDmax) | direct |
| tdvs | 0..1 Seconds |
Time delay after deep voltage sags (TDVS)... | direct |
| thetaemin | 0..1 PU |
Minimum electrical generator torque (temin) | direct |
| thetauscale | 0..1 PU |
Voltage scaling factor of reset-torque (tuscale) | direct |
| tomegafiltp | 0..1 Seconds |
Filter time constant for generator speed measurement (Tomegafiltp... | direct |
| tomegaref | 0..1 Seconds |
Time constant in speed reference filter (Tomega,ref) (>=... | direct |
| tpfiltp | 0..1 Seconds |
Filter time constant for power measurement (Tpfiltp3) (>... | direct |
| tpord | 0..1 PU |
Time constant in power order lag (Tpord) | direct |
| tufiltp | 0..1 Seconds |
Filter time constant for voltage measurement (Tufiltp3) (&g... | direct |
| udvs | 0..1 PU |
Voltage limit for hold UVRT status after deep voltage sags (uD... | direct |
| updip | 0..1 PU |
Voltage dip threshold for P-control (uPdip) | direct |
| zeta | 0..1 Float |
Coefficient for active drive train damping (zeta) | direct |
| wind_turbine_type_iec | 1..1 WindTurbineType3IEC |
Wind turbine type 3 model with which this wind control P type 3 model is asso... | direct |
| wind_dynamics_lookup_table | 1..* WindDynamicsLookupTable |
The wind dynamics lookup table associated with this P control type 3 model | direct |
| alias_name | 0..1 String |
The aliasName is free text human readable name of the object alternative to I... | IdentifiedObject |
| description | 0..1 String |
The description is a free human readable text describing or naming the object | IdentifiedObject |
| m_rid | 0..1 String |
Master resource identifier issued by a model authority | IdentifiedObject |
| diagram_objects | 0..* DiagramObject |
The diagram objects that are associated with the domain object | IdentifiedObject |
| instance_set | 1..1 InstanceSet |
Dataset containing the data objects | IdentifiedObject |
| names | 0..* Name |
All names of this identified object | IdentifiedObject |
| properties_cimdata_object | 0..1 ChangeSetMember |
The single CIM data object in the appropriate dataset context | IdentifiedObject |
| targeting_cimdata_object | 0..* ChangeSetMember |
Data objects registered | IdentifiedObject |
Usages
| used by | used in | type | used |
|---|---|---|---|
| WindDynamicsLookupTable | wind_cont_ptype_iec | range | WindContPType3IEC |
| WindTurbineType3IEC | wind_cont_ptype_iec | range | WindContPType3IEC |
Identifier and Mapping Information
Schema Source
- from schema: https://cim.ucaiug.io/ns#TC57CIM
Mappings
| Mapping Type | Mapped Value |
|---|---|
| self | cim:WindContPType3IEC |
| native | cim:WindContPType3IEC |
LinkML Source
Direct
name: WindContPType3IEC
description: "P control model type 3.\r\nReference: IEC 61400-27-1:2015, 5.6.5.4."
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
is_a: IdentifiedObject
attributes:
dpmax:
name: dpmax
description: Maximum wind turbine power ramp rate (<i>dp</i><i><sub>max</sub></i>).
It is a type-dependent parameter.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:WindContPType3IEC.dpmax
multivalued: false
domain_of:
- WindContPType3IEC
- WindPitchContPowerIEC
range: PU
required: false
dprefmax:
name: dprefmax
description: Maximum ramp rate of wind turbine reference power (<i>dp</i><i><sub>refmax</sub></i>).
It is a project-dependent parameter.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:WindContPType3IEC.dprefmax
multivalued: false
domain_of:
- WindPlantFreqPcontrolIEC
- WindContPType3IEC
range: PU
required: false
dprefmin:
name: dprefmin
description: Minimum ramp rate of wind turbine reference power (<i>dp</i><i><sub>refmin</sub></i>).
It is a project-dependent parameter.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:WindContPType3IEC.dprefmin
multivalued: false
domain_of:
- WindPlantFreqPcontrolIEC
- WindContPType3IEC
range: PU
required: false
dthetamax:
name: dthetamax
description: Ramp limitation of torque, required in some grid codes (<i>dt</i><i><sub>max</sub></i>).
It is a project-dependent parameter.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:WindContPType3IEC.dthetamax
multivalued: false
domain_of:
- WindContPitchAngleIEC
- WindContPType3IEC
range: PU
required: false
dthetamaxuvrt:
name: dthetamaxuvrt
description: Limitation of torque rise rate during UVRT (<i>dtheta</i><i><sub>maxUVRT</sub></i>).
It is a project-dependent parameter.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:WindContPType3IEC.dthetamaxuvrt
multivalued: false
domain_of:
- WindContPType3IEC
range: PU
required: false
kdtd:
name: kdtd
description: Gain for active drive train damping (<i>K</i><i><sub>DTD</sub></i>).
It is a type-dependent parameter.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:WindContPType3IEC.kdtd
multivalued: false
domain_of:
- WindContPType3IEC
range: PU
required: false
kip:
name: kip
description: PI controller integration parameter (<i>K</i><sub>Ip</sub>). It is
a type-dependent parameter.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:WindContPType3IEC.kip
multivalued: false
domain_of:
- GovSteamFV4
- ExcREXS
- WindContPType3IEC
range: PU
required: false
kpp:
name: kpp
description: PI controller proportional gain (<i>K</i><sub>Pp</sub>). It is a
type-dependent parameter.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:WindContPType3IEC.kpp
multivalued: false
domain_of:
- GovSteamFV4
- WindContPType3IEC
range: PU
required: false
mpuvrt:
name: mpuvrt
description: "Enable UVRT power control mode (<i>M</i><i><sub>pUVRT</sub></i><sub>)</sub>.\
\ It is a project-dependent parameter.\r\ntrue = voltage control (1 in the\
\ IEC model)\r\nfalse = reactive power control (0 in the IEC model).\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:WindContPType3IEC.mpuvrt
multivalued: false
domain_of:
- WindContPType3IEC
range: boolean
required: false
omegadtd:
name: omegadtd
description: Active drive train damping frequency (<i>omega</i><i><sub>DTD</sub></i>).
It can be calculated from two mass model parameters. It is a type-dependent
parameter.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:WindContPType3IEC.omegadtd
multivalued: false
domain_of:
- WindContPType3IEC
range: PU
required: false
omegaoffset:
name: omegaoffset
description: Offset to reference value that limits controller action during rotor
speed changes (<i>omega</i><i><sub>offset</sub></i>). It is a case-dependent
parameter.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:WindContPType3IEC.omegaoffset
multivalued: false
domain_of:
- WindContPType3IEC
range: PU
required: false
pdtdmax:
name: pdtdmax
description: Maximum active drive train damping power (<i>p</i><sub>DTDmax</sub>).
It is a type-dependent parameter.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:WindContPType3IEC.pdtdmax
multivalued: false
domain_of:
- WindContPType3IEC
range: PU
required: false
tdvs:
name: tdvs
description: Time<sub> </sub>delay after deep voltage sags (<i>T</i><i><sub>DVS</sub></i>)
(>= 0). It is a project-dependent parameter.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:WindContPType3IEC.tdvs
multivalued: false
domain_of:
- WindContPType3IEC
range: Seconds
required: false
thetaemin:
name: thetaemin
description: Minimum electrical generator torque (<i>t</i><sub>emin</sub>). It
is a type-dependent parameter.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:WindContPType3IEC.thetaemin
multivalued: false
domain_of:
- WindContPType3IEC
range: PU
required: false
thetauscale:
name: thetauscale
description: Voltage scaling factor of reset-torque (<i>t</i><sub>uscale</sub>).
It is a project-dependent parameter.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:WindContPType3IEC.thetauscale
multivalued: false
domain_of:
- WindContPType3IEC
range: PU
required: false
tomegafiltp:
name: tomegafiltp
description: Filter time constant for generator speed measurement (<i>T</i><sub>omegafiltp3</sub>)
(>= 0). It is a type-dependent parameter.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:WindContPType3IEC.tomegafiltp3
multivalued: false
domain_of:
- WindContPType3IEC
range: Seconds
required: false
tomegaref:
name: tomegaref
description: Time constant in speed reference filter (<i>T</i><sub>omega,ref</sub>)
(>= 0). It is a type-dependent parameter.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:WindContPType3IEC.tomegaref
multivalued: false
domain_of:
- WindContPType3IEC
range: Seconds
required: false
tpfiltp:
name: tpfiltp
description: Filter time constant for power measurement (<i>T</i><sub>pfiltp3</sub>)
(>= 0). It is a type-dependent parameter.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:WindContPType3IEC.tpfiltp3
multivalued: false
domain_of:
- WindContPType3IEC
range: Seconds
required: false
tpord:
name: tpord
description: Time constant in power order lag (<i>T</i><sub>pord</sub>). It is
a type-dependent parameter.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:WindContPType3IEC.tpord
multivalued: false
domain_of:
- WindContPType3IEC
range: PU
required: false
tufiltp:
name: tufiltp
description: Filter time constant for voltage measurement (<i>T</i><sub>ufiltp3</sub>)
(>= 0). It is a type-dependent parameter.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:WindContPType3IEC.tufiltp3
multivalued: false
domain_of:
- WindContPType3IEC
range: Seconds
required: false
udvs:
name: udvs
description: Voltage limit for hold UVRT status after deep voltage sags (<i>u</i><i><sub>DVS</sub></i>).
It is a project-dependent parameter.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:WindContPType3IEC.udvs
multivalued: false
domain_of:
- WindContPType3IEC
range: PU
required: false
updip:
name: updip
description: Voltage dip threshold for P-control (<i>u</i><sub>Pdip</sub>). Part
of turbine control, often different (e.g 0.8) from converter thresholds. It
is a project-dependent parameter.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:WindContPType3IEC.updip
multivalued: false
domain_of:
- WindContPType3IEC
range: PU
required: false
zeta:
name: zeta
description: Coefficient for active drive train damping (<i>zeta</i>). It is a
type-dependent parameter.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:WindContPType3IEC.zeta
multivalued: false
domain_of:
- WindContPType3IEC
range: float
required: false
wind_turbine_type_iec:
name: wind_turbine_type_iec
description: Wind turbine type 3 model with which this wind control P type 3 model
is associated.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:WindContPType3IEC.WindTurbineType3IEC
multivalued: false
domain_of:
- WindMechIEC
- WindGenType3aIEC
- WindGenType3IEC
- WindAeroTwoDimIEC
- WindContPitchAngleIEC
- WindContPType3IEC
- WindAeroOneDimIEC
range: WindTurbineType3IEC
required: true
wind_dynamics_lookup_table:
name: wind_dynamics_lookup_table
description: The wind dynamics lookup table associated with this P control type
3 model.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:WindContPType3IEC.WindDynamicsLookupTable
multivalued: true
domain_of:
- WindPlantFreqPcontrolIEC
- WindPlantReactiveControlIEC
- WindProtectionIEC
- WindContQPQULimIEC
- WindContCurrLimIEC
- WindContPType3IEC
- WindContRotorRIEC
- WindPitchContPowerIEC
- WindGenType3bIEC
range: WindDynamicsLookupTable
required: true
class_uri: cim:WindContPType3IEC
Induced
name: WindContPType3IEC
description: "P control model type 3.\r\nReference: IEC 61400-27-1:2015, 5.6.5.4."
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
is_a: IdentifiedObject
attributes:
dpmax:
name: dpmax
description: Maximum wind turbine power ramp rate (<i>dp</i><i><sub>max</sub></i>).
It is a type-dependent parameter.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:WindContPType3IEC.dpmax
multivalued: false
alias: dpmax
owner: WindContPType3IEC
domain_of:
- WindContPType3IEC
- WindPitchContPowerIEC
range: PU
required: false
dprefmax:
name: dprefmax
description: Maximum ramp rate of wind turbine reference power (<i>dp</i><i><sub>refmax</sub></i>).
It is a project-dependent parameter.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:WindContPType3IEC.dprefmax
multivalued: false
alias: dprefmax
owner: WindContPType3IEC
domain_of:
- WindPlantFreqPcontrolIEC
- WindContPType3IEC
range: PU
required: false
dprefmin:
name: dprefmin
description: Minimum ramp rate of wind turbine reference power (<i>dp</i><i><sub>refmin</sub></i>).
It is a project-dependent parameter.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:WindContPType3IEC.dprefmin
multivalued: false
alias: dprefmin
owner: WindContPType3IEC
domain_of:
- WindPlantFreqPcontrolIEC
- WindContPType3IEC
range: PU
required: false
dthetamax:
name: dthetamax
description: Ramp limitation of torque, required in some grid codes (<i>dt</i><i><sub>max</sub></i>).
It is a project-dependent parameter.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:WindContPType3IEC.dthetamax
multivalued: false
alias: dthetamax
owner: WindContPType3IEC
domain_of:
- WindContPitchAngleIEC
- WindContPType3IEC
range: PU
required: false
dthetamaxuvrt:
name: dthetamaxuvrt
description: Limitation of torque rise rate during UVRT (<i>dtheta</i><i><sub>maxUVRT</sub></i>).
It is a project-dependent parameter.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:WindContPType3IEC.dthetamaxuvrt
multivalued: false
alias: dthetamaxuvrt
owner: WindContPType3IEC
domain_of:
- WindContPType3IEC
range: PU
required: false
kdtd:
name: kdtd
description: Gain for active drive train damping (<i>K</i><i><sub>DTD</sub></i>).
It is a type-dependent parameter.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:WindContPType3IEC.kdtd
multivalued: false
alias: kdtd
owner: WindContPType3IEC
domain_of:
- WindContPType3IEC
range: PU
required: false
kip:
name: kip
description: PI controller integration parameter (<i>K</i><sub>Ip</sub>). It is
a type-dependent parameter.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:WindContPType3IEC.kip
multivalued: false
alias: kip
owner: WindContPType3IEC
domain_of:
- GovSteamFV4
- ExcREXS
- WindContPType3IEC
range: PU
required: false
kpp:
name: kpp
description: PI controller proportional gain (<i>K</i><sub>Pp</sub>). It is a
type-dependent parameter.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:WindContPType3IEC.kpp
multivalued: false
alias: kpp
owner: WindContPType3IEC
domain_of:
- GovSteamFV4
- WindContPType3IEC
range: PU
required: false
mpuvrt:
name: mpuvrt
description: "Enable UVRT power control mode (<i>M</i><i><sub>pUVRT</sub></i><sub>)</sub>.\
\ It is a project-dependent parameter.\r\ntrue = voltage control (1 in the\
\ IEC model)\r\nfalse = reactive power control (0 in the IEC model).\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:WindContPType3IEC.mpuvrt
multivalued: false
alias: mpuvrt
owner: WindContPType3IEC
domain_of:
- WindContPType3IEC
range: boolean
required: false
omegadtd:
name: omegadtd
description: Active drive train damping frequency (<i>omega</i><i><sub>DTD</sub></i>).
It can be calculated from two mass model parameters. It is a type-dependent
parameter.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:WindContPType3IEC.omegadtd
multivalued: false
alias: omegadtd
owner: WindContPType3IEC
domain_of:
- WindContPType3IEC
range: PU
required: false
omegaoffset:
name: omegaoffset
description: Offset to reference value that limits controller action during rotor
speed changes (<i>omega</i><i><sub>offset</sub></i>). It is a case-dependent
parameter.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:WindContPType3IEC.omegaoffset
multivalued: false
alias: omegaoffset
owner: WindContPType3IEC
domain_of:
- WindContPType3IEC
range: PU
required: false
pdtdmax:
name: pdtdmax
description: Maximum active drive train damping power (<i>p</i><sub>DTDmax</sub>).
It is a type-dependent parameter.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:WindContPType3IEC.pdtdmax
multivalued: false
alias: pdtdmax
owner: WindContPType3IEC
domain_of:
- WindContPType3IEC
range: PU
required: false
tdvs:
name: tdvs
description: Time<sub> </sub>delay after deep voltage sags (<i>T</i><i><sub>DVS</sub></i>)
(>= 0). It is a project-dependent parameter.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:WindContPType3IEC.tdvs
multivalued: false
alias: tdvs
owner: WindContPType3IEC
domain_of:
- WindContPType3IEC
range: Seconds
required: false
thetaemin:
name: thetaemin
description: Minimum electrical generator torque (<i>t</i><sub>emin</sub>). It
is a type-dependent parameter.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:WindContPType3IEC.thetaemin
multivalued: false
alias: thetaemin
owner: WindContPType3IEC
domain_of:
- WindContPType3IEC
range: PU
required: false
thetauscale:
name: thetauscale
description: Voltage scaling factor of reset-torque (<i>t</i><sub>uscale</sub>).
It is a project-dependent parameter.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:WindContPType3IEC.thetauscale
multivalued: false
alias: thetauscale
owner: WindContPType3IEC
domain_of:
- WindContPType3IEC
range: PU
required: false
tomegafiltp:
name: tomegafiltp
description: Filter time constant for generator speed measurement (<i>T</i><sub>omegafiltp3</sub>)
(>= 0). It is a type-dependent parameter.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:WindContPType3IEC.tomegafiltp3
multivalued: false
alias: tomegafiltp
owner: WindContPType3IEC
domain_of:
- WindContPType3IEC
range: Seconds
required: false
tomegaref:
name: tomegaref
description: Time constant in speed reference filter (<i>T</i><sub>omega,ref</sub>)
(>= 0). It is a type-dependent parameter.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:WindContPType3IEC.tomegaref
multivalued: false
alias: tomegaref
owner: WindContPType3IEC
domain_of:
- WindContPType3IEC
range: Seconds
required: false
tpfiltp:
name: tpfiltp
description: Filter time constant for power measurement (<i>T</i><sub>pfiltp3</sub>)
(>= 0). It is a type-dependent parameter.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:WindContPType3IEC.tpfiltp3
multivalued: false
alias: tpfiltp
owner: WindContPType3IEC
domain_of:
- WindContPType3IEC
range: Seconds
required: false
tpord:
name: tpord
description: Time constant in power order lag (<i>T</i><sub>pord</sub>). It is
a type-dependent parameter.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:WindContPType3IEC.tpord
multivalued: false
alias: tpord
owner: WindContPType3IEC
domain_of:
- WindContPType3IEC
range: PU
required: false
tufiltp:
name: tufiltp
description: Filter time constant for voltage measurement (<i>T</i><sub>ufiltp3</sub>)
(>= 0). It is a type-dependent parameter.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:WindContPType3IEC.tufiltp3
multivalued: false
alias: tufiltp
owner: WindContPType3IEC
domain_of:
- WindContPType3IEC
range: Seconds
required: false
udvs:
name: udvs
description: Voltage limit for hold UVRT status after deep voltage sags (<i>u</i><i><sub>DVS</sub></i>).
It is a project-dependent parameter.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:WindContPType3IEC.udvs
multivalued: false
alias: udvs
owner: WindContPType3IEC
domain_of:
- WindContPType3IEC
range: PU
required: false
updip:
name: updip
description: Voltage dip threshold for P-control (<i>u</i><sub>Pdip</sub>). Part
of turbine control, often different (e.g 0.8) from converter thresholds. It
is a project-dependent parameter.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:WindContPType3IEC.updip
multivalued: false
alias: updip
owner: WindContPType3IEC
domain_of:
- WindContPType3IEC
range: PU
required: false
zeta:
name: zeta
description: Coefficient for active drive train damping (<i>zeta</i>). It is a
type-dependent parameter.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:WindContPType3IEC.zeta
multivalued: false
alias: zeta
owner: WindContPType3IEC
domain_of:
- WindContPType3IEC
range: float
required: false
wind_turbine_type_iec:
name: wind_turbine_type_iec
description: Wind turbine type 3 model with which this wind control P type 3 model
is associated.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:WindContPType3IEC.WindTurbineType3IEC
multivalued: false
alias: wind_turbine_type_iec
owner: WindContPType3IEC
domain_of:
- WindMechIEC
- WindGenType3aIEC
- WindGenType3IEC
- WindAeroTwoDimIEC
- WindContPitchAngleIEC
- WindContPType3IEC
- WindAeroOneDimIEC
range: WindTurbineType3IEC
required: true
wind_dynamics_lookup_table:
name: wind_dynamics_lookup_table
description: The wind dynamics lookup table associated with this P control type
3 model.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:WindContPType3IEC.WindDynamicsLookupTable
multivalued: true
alias: wind_dynamics_lookup_table
owner: WindContPType3IEC
domain_of:
- WindPlantFreqPcontrolIEC
- WindPlantReactiveControlIEC
- WindProtectionIEC
- WindContQPQULimIEC
- WindContCurrLimIEC
- WindContPType3IEC
- WindContRotorRIEC
- WindPitchContPowerIEC
- WindGenType3bIEC
range: WindDynamicsLookupTable
required: true
alias_name:
name: alias_name
description: "The aliasName is free text human readable name of the object alternative\
\ to IdentifiedObject.name. It may be non unique and may not correlate to a\
\ naming hierarchy.\r\nThe attribute aliasName is retained because of backwards\
\ compatibility between CIM relases. It is however recommended to replace aliasName\
\ with the Name class as aliasName is planned for retirement at a future time.\r\
\n\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.aliasName
multivalued: false
alias: alias_name
owner: WindContPType3IEC
domain_of:
- IdentifiedObject
range: string
required: false
description:
name: description
description: The description is a free human readable text describing or naming
the object. It may be non unique and may not correlate to a naming hierarchy.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.description
multivalued: false
alias: description
owner: WindContPType3IEC
domain_of:
- IdentifiedObject
- NameType
- NameTypeAuthority
- DataSet
- SwitchingStepGroup
- AreaReserveSpec
range: string
required: false
m_rid:
name: m_rid
description: "Master resource identifier issued by a model authority. The mRID\
\ is unique within an exchange context. Global uniqueness is easily achieved\
\ by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is\
\ strongly recommended.\r\nFor CIMXML data files in RDF syntax conforming to\
\ IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify\
\ CIM object elements."
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.mRID
multivalued: false
alias: m_rid
owner: WindContPType3IEC
domain_of:
- IdentifiedObject
- DataSet
range: string
required: false
diagram_objects:
name: diagram_objects
description: The diagram objects that are associated with the domain object.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.DiagramObjects
multivalued: true
alias: diagram_objects
owner: WindContPType3IEC
domain_of:
- IdentifiedObject
range: DiagramObject
required: false
instance_set:
name: instance_set
description: Dataset containing the data objects.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.InstanceSet
multivalued: false
alias: instance_set
owner: WindContPType3IEC
domain_of:
- IdentifiedObject
range: InstanceSet
required: true
names:
name: names
description: All names of this identified object.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.Names
multivalued: true
alias: names
owner: WindContPType3IEC
domain_of:
- IdentifiedObject
- NameType
range: Name
required: false
properties_cimdata_object:
name: properties_cimdata_object
description: The single CIM data object in the appropriate dataset context.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.PropertiesCIMDataObject
multivalued: false
alias: properties_cimdata_object
owner: WindContPType3IEC
domain_of:
- IdentifiedObject
range: ChangeSetMember
required: false
targeting_cimdata_object:
name: targeting_cimdata_object
description: Data objects registered.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.TargetingCIMDataObject
multivalued: true
alias: targeting_cimdata_object
owner: WindContPType3IEC
domain_of:
- IdentifiedObject
range: ChangeSetMember
required: false