Class: WindContCurrLimIEC
_Current limitation model. The current limitation model combines the physical limits and the control limits. _
Reference: IEC 61400-27-1:2015, 5.6.5.8.
classDiagram
class WindContCurrLimIEC
IdentifiedObject <|-- WindContCurrLimIEC
WindContCurrLimIEC : alias_name
WindContCurrLimIEC : description
WindContCurrLimIEC : diagram_objects
WindContCurrLimIEC --> DiagramObject : diagram_objects
WindContCurrLimIEC : imax
WindContCurrLimIEC --> PU : imax
WindContCurrLimIEC : imaxdip
WindContCurrLimIEC --> PU : imaxdip
WindContCurrLimIEC : instance_set
WindContCurrLimIEC --> InstanceSet : instance_set
WindContCurrLimIEC : kpqu
WindContCurrLimIEC --> PU : kpqu
WindContCurrLimIEC : m_rid
WindContCurrLimIEC : mdfslim
WindContCurrLimIEC : mqpri
WindContCurrLimIEC : names
WindContCurrLimIEC --> Name : names
WindContCurrLimIEC : properties_cimdata_object
WindContCurrLimIEC --> ChangeSetMember : properties_cimdata_object
WindContCurrLimIEC : targeting_cimdata_object
WindContCurrLimIEC --> ChangeSetMember : targeting_cimdata_object
WindContCurrLimIEC : tufiltcl
WindContCurrLimIEC --> Seconds : tufiltcl
WindContCurrLimIEC : upqumax
WindContCurrLimIEC --> PU : upqumax
WindContCurrLimIEC : wind_dynamics_lookup_table
WindContCurrLimIEC --> WindDynamicsLookupTable : wind_dynamics_lookup_table
WindContCurrLimIEC : wind_turbine_type_or_iec
WindContCurrLimIEC --> WindTurbineType3or4IEC : wind_turbine_type_or_iec
Inheritance
- IdentifiedObject
- WindContCurrLimIEC
Slots
| Name | Cardinality and Range | Description | Inheritance |
|---|---|---|---|
| imax | 0..1 PU |
Maximum continuous current at the wind turbine terminals (imax... | direct |
| imaxdip | 0..1 PU |
Maximum current during voltage dip at the wind turbine terminals (i... | direct |
| kpqu | 0..1 PU |
Partial derivative of reactive current limit (Kpqu) ... | direct |
| mdfslim | 0..1 Boolean |
Limitation of type 3 stator current (MDFSLim) | direct |
| mqpri | 0..1 Boolean |
Prioritisation of Q control during UVRT (Mqpri) | direct |
| tufiltcl | 0..1 Seconds |
Voltage measurement filter time constant (Tufiltcl) ... | direct |
| upqumax | 0..1 PU |
Wind turbine voltage in the operation point where zero reactive current can b... | direct |
| wind_turbine_type_or_iec | 1..1 WindTurbineType3or4IEC |
Wind turbine type 3 or type 4 model with which this wind control current limi... | direct |
| wind_dynamics_lookup_table | 1..* WindDynamicsLookupTable |
The wind dynamics lookup table associated with this current control limitatio... | direct |
| alias_name | 0..1 String |
The aliasName is free text human readable name of the object alternative to I... | IdentifiedObject |
| description | 0..1 String |
The description is a free human readable text describing or naming the object | IdentifiedObject |
| m_rid | 0..1 String |
Master resource identifier issued by a model authority | IdentifiedObject |
| diagram_objects | 0..* DiagramObject |
The diagram objects that are associated with the domain object | IdentifiedObject |
| instance_set | 1..1 InstanceSet |
Dataset containing the data objects | IdentifiedObject |
| names | 0..* Name |
All names of this identified object | IdentifiedObject |
| properties_cimdata_object | 0..1 ChangeSetMember |
The single CIM data object in the appropriate dataset context | IdentifiedObject |
| targeting_cimdata_object | 0..* ChangeSetMember |
Data objects registered | IdentifiedObject |
Usages
Identifier and Mapping Information
Schema Source
- from schema: https://cim.ucaiug.io/ns#TC57CIM
Mappings
| Mapping Type | Mapped Value |
|---|---|
| self | cim:WindContCurrLimIEC |
| native | cim:WindContCurrLimIEC |
LinkML Source
Direct
name: WindContCurrLimIEC
description: "Current limitation model. The current limitation model combines the\
\ physical limits and the control limits.\r\nReference: IEC 61400-27-1:2015, 5.6.5.8."
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
is_a: IdentifiedObject
attributes:
imax:
name: imax
description: Maximum continuous current at the wind turbine terminals (<i>i</i><i><sub>max</sub></i>).
It is a type-dependent parameter.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:WindContCurrLimIEC.imax
multivalued: false
domain_of:
- ExcHU
- WindContCurrLimIEC
range: PU
required: false
imaxdip:
name: imaxdip
description: Maximum current during voltage dip at the wind turbine terminals
(<i>i</i><i><sub>maxdip</sub></i>). It is a project-dependent parameter.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:WindContCurrLimIEC.imaxdip
multivalued: false
domain_of:
- WindContCurrLimIEC
range: PU
required: false
kpqu:
name: kpqu
description: Partial derivative of reactive current limit (<i>K</i><i><sub>pqu</sub></i>)
versus voltage. It is a type-dependent parameter.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:WindContCurrLimIEC.kpqu
multivalued: false
domain_of:
- WindContCurrLimIEC
range: PU
required: false
mdfslim:
name: mdfslim
description: "Limitation of type 3 stator current (<i>M</i><i><sub>DFSLim</sub></i>).\
\ <i>M</i><i><sub>DFSLim</sub></i><sub> </sub>= 1 for wind turbines type 4.\
\ It is a type-dependent parameter.\r\nfalse= total current limitation (0 in\
\ the IEC model)\r\ntrue=stator current limitation (1 in the IEC model).\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:WindContCurrLimIEC.mdfslim
multivalued: false
domain_of:
- WindContCurrLimIEC
range: boolean
required: false
mqpri:
name: mqpri
description: "Prioritisation of Q control during UVRT (<i>M</i><i><sub>qpri</sub></i>).\
\ It is a project-dependent parameter.\r\ntrue = reactive power priority (1\
\ in the IEC model)\r\nfalse = active power priority (0 in the IEC model)."
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:WindContCurrLimIEC.mqpri
multivalued: false
domain_of:
- WindContCurrLimIEC
range: boolean
required: false
tufiltcl:
name: tufiltcl
description: Voltage measurement filter time constant (<i>T</i><i><sub>ufiltcl</sub></i>)
(>= 0). It is a type-dependent parameter.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:WindContCurrLimIEC.tufiltcl
multivalued: false
domain_of:
- WindContCurrLimIEC
range: Seconds
required: false
upqumax:
name: upqumax
description: Wind turbine voltage in the operation point where zero reactive current
can be delivered (<i>u</i><i><sub>pqumax</sub></i>). It is a type-dependent
parameter.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:WindContCurrLimIEC.upqumax
multivalued: false
domain_of:
- WindContCurrLimIEC
range: PU
required: false
wind_turbine_type_or_iec:
name: wind_turbine_type_or_iec
description: Wind turbine type 3 or type 4 model with which this wind control
current limitation model is associated.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:WindContCurrLimIEC.WindTurbineType3or4IEC
multivalued: false
domain_of:
- WindProtectionIEC
- WindContQPQULimIEC
- WindContCurrLimIEC
- WindContQIEC
- WindRefFrameRotIEC
- WindContQLimIEC
- WindMechIEC
range: WindTurbineType3or4IEC
required: true
wind_dynamics_lookup_table:
name: wind_dynamics_lookup_table
description: The wind dynamics lookup table associated with this current control
limitation model.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:WindContCurrLimIEC.WindDynamicsLookupTable
multivalued: true
domain_of:
- WindPlantFreqPcontrolIEC
- WindPlantReactiveControlIEC
- WindProtectionIEC
- WindContQPQULimIEC
- WindContCurrLimIEC
- WindContPType3IEC
- WindContRotorRIEC
- WindPitchContPowerIEC
- WindGenType3bIEC
range: WindDynamicsLookupTable
required: true
class_uri: cim:WindContCurrLimIEC
Induced
name: WindContCurrLimIEC
description: "Current limitation model. The current limitation model combines the\
\ physical limits and the control limits.\r\nReference: IEC 61400-27-1:2015, 5.6.5.8."
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
is_a: IdentifiedObject
attributes:
imax:
name: imax
description: Maximum continuous current at the wind turbine terminals (<i>i</i><i><sub>max</sub></i>).
It is a type-dependent parameter.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:WindContCurrLimIEC.imax
multivalued: false
alias: imax
owner: WindContCurrLimIEC
domain_of:
- ExcHU
- WindContCurrLimIEC
range: PU
required: false
imaxdip:
name: imaxdip
description: Maximum current during voltage dip at the wind turbine terminals
(<i>i</i><i><sub>maxdip</sub></i>). It is a project-dependent parameter.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:WindContCurrLimIEC.imaxdip
multivalued: false
alias: imaxdip
owner: WindContCurrLimIEC
domain_of:
- WindContCurrLimIEC
range: PU
required: false
kpqu:
name: kpqu
description: Partial derivative of reactive current limit (<i>K</i><i><sub>pqu</sub></i>)
versus voltage. It is a type-dependent parameter.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:WindContCurrLimIEC.kpqu
multivalued: false
alias: kpqu
owner: WindContCurrLimIEC
domain_of:
- WindContCurrLimIEC
range: PU
required: false
mdfslim:
name: mdfslim
description: "Limitation of type 3 stator current (<i>M</i><i><sub>DFSLim</sub></i>).\
\ <i>M</i><i><sub>DFSLim</sub></i><sub> </sub>= 1 for wind turbines type 4.\
\ It is a type-dependent parameter.\r\nfalse= total current limitation (0 in\
\ the IEC model)\r\ntrue=stator current limitation (1 in the IEC model).\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:WindContCurrLimIEC.mdfslim
multivalued: false
alias: mdfslim
owner: WindContCurrLimIEC
domain_of:
- WindContCurrLimIEC
range: boolean
required: false
mqpri:
name: mqpri
description: "Prioritisation of Q control during UVRT (<i>M</i><i><sub>qpri</sub></i>).\
\ It is a project-dependent parameter.\r\ntrue = reactive power priority (1\
\ in the IEC model)\r\nfalse = active power priority (0 in the IEC model)."
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:WindContCurrLimIEC.mqpri
multivalued: false
alias: mqpri
owner: WindContCurrLimIEC
domain_of:
- WindContCurrLimIEC
range: boolean
required: false
tufiltcl:
name: tufiltcl
description: Voltage measurement filter time constant (<i>T</i><i><sub>ufiltcl</sub></i>)
(>= 0). It is a type-dependent parameter.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:WindContCurrLimIEC.tufiltcl
multivalued: false
alias: tufiltcl
owner: WindContCurrLimIEC
domain_of:
- WindContCurrLimIEC
range: Seconds
required: false
upqumax:
name: upqumax
description: Wind turbine voltage in the operation point where zero reactive current
can be delivered (<i>u</i><i><sub>pqumax</sub></i>). It is a type-dependent
parameter.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:WindContCurrLimIEC.upqumax
multivalued: false
alias: upqumax
owner: WindContCurrLimIEC
domain_of:
- WindContCurrLimIEC
range: PU
required: false
wind_turbine_type_or_iec:
name: wind_turbine_type_or_iec
description: Wind turbine type 3 or type 4 model with which this wind control
current limitation model is associated.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:WindContCurrLimIEC.WindTurbineType3or4IEC
multivalued: false
alias: wind_turbine_type_or_iec
owner: WindContCurrLimIEC
domain_of:
- WindProtectionIEC
- WindContQPQULimIEC
- WindContCurrLimIEC
- WindContQIEC
- WindRefFrameRotIEC
- WindContQLimIEC
- WindMechIEC
range: WindTurbineType3or4IEC
required: true
wind_dynamics_lookup_table:
name: wind_dynamics_lookup_table
description: The wind dynamics lookup table associated with this current control
limitation model.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:WindContCurrLimIEC.WindDynamicsLookupTable
multivalued: true
alias: wind_dynamics_lookup_table
owner: WindContCurrLimIEC
domain_of:
- WindPlantFreqPcontrolIEC
- WindPlantReactiveControlIEC
- WindProtectionIEC
- WindContQPQULimIEC
- WindContCurrLimIEC
- WindContPType3IEC
- WindContRotorRIEC
- WindPitchContPowerIEC
- WindGenType3bIEC
range: WindDynamicsLookupTable
required: true
alias_name:
name: alias_name
description: "The aliasName is free text human readable name of the object alternative\
\ to IdentifiedObject.name. It may be non unique and may not correlate to a\
\ naming hierarchy.\r\nThe attribute aliasName is retained because of backwards\
\ compatibility between CIM relases. It is however recommended to replace aliasName\
\ with the Name class as aliasName is planned for retirement at a future time.\r\
\n\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.aliasName
multivalued: false
alias: alias_name
owner: WindContCurrLimIEC
domain_of:
- IdentifiedObject
range: string
required: false
description:
name: description
description: The description is a free human readable text describing or naming
the object. It may be non unique and may not correlate to a naming hierarchy.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.description
multivalued: false
alias: description
owner: WindContCurrLimIEC
domain_of:
- IdentifiedObject
- NameType
- NameTypeAuthority
- DataSet
- SwitchingStepGroup
- AreaReserveSpec
range: string
required: false
m_rid:
name: m_rid
description: "Master resource identifier issued by a model authority. The mRID\
\ is unique within an exchange context. Global uniqueness is easily achieved\
\ by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is\
\ strongly recommended.\r\nFor CIMXML data files in RDF syntax conforming to\
\ IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify\
\ CIM object elements."
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.mRID
multivalued: false
alias: m_rid
owner: WindContCurrLimIEC
domain_of:
- IdentifiedObject
- DataSet
range: string
required: false
diagram_objects:
name: diagram_objects
description: The diagram objects that are associated with the domain object.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.DiagramObjects
multivalued: true
alias: diagram_objects
owner: WindContCurrLimIEC
domain_of:
- IdentifiedObject
range: DiagramObject
required: false
instance_set:
name: instance_set
description: Dataset containing the data objects.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.InstanceSet
multivalued: false
alias: instance_set
owner: WindContCurrLimIEC
domain_of:
- IdentifiedObject
range: InstanceSet
required: true
names:
name: names
description: All names of this identified object.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.Names
multivalued: true
alias: names
owner: WindContCurrLimIEC
domain_of:
- IdentifiedObject
- NameType
range: Name
required: false
properties_cimdata_object:
name: properties_cimdata_object
description: The single CIM data object in the appropriate dataset context.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.PropertiesCIMDataObject
multivalued: false
alias: properties_cimdata_object
owner: WindContCurrLimIEC
domain_of:
- IdentifiedObject
range: ChangeSetMember
required: false
targeting_cimdata_object:
name: targeting_cimdata_object
description: Data objects registered.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.TargetingCIMDataObject
multivalued: true
alias: targeting_cimdata_object
owner: WindContCurrLimIEC
domain_of:
- IdentifiedObject
range: ChangeSetMember
required: false
class_uri: cim:WindContCurrLimIEC