Class: VsConverter
DC side of the voltage source converter (VSC).
URI: cim:VsConverter
classDiagram
class VsConverter
ACDCConverter <|-- VsConverter
VsConverter : additional_equipment_container
VsConverter --> EquipmentContainer : additional_equipment_container
VsConverter : aggregate
VsConverter : alias_name
VsConverter : asset_datasheet
VsConverter --> AssetInfo : asset_datasheet
VsConverter : assets
VsConverter --> Asset : assets
VsConverter : base_s
VsConverter --> ApparentPower : base_s
VsConverter : base_voltage
VsConverter --> BaseVoltage : base_voltage
VsConverter : capability_curve
VsConverter --> VsCapabilityCurve : capability_curve
VsConverter : clearances
VsConverter --> ClearanceDocument : clearances
VsConverter : configuration_event
VsConverter --> ConfigurationEvent : configuration_event
VsConverter : contingency_equipment
VsConverter --> ContingencyEquipment : contingency_equipment
VsConverter : controls
VsConverter --> Control : controls
VsConverter : dcterminals
VsConverter --> ACDCConverterDCTerminal : dcterminals
VsConverter : delta
VsConverter --> AngleDegrees : delta
VsConverter : description
VsConverter : diagram_objects
VsConverter --> DiagramObject : diagram_objects
VsConverter : droop
VsConverter --> PU : droop
VsConverter : droop_compensation
VsConverter --> Resistance : droop_compensation
VsConverter : eqiupment_limit_series_component
VsConverter --> EquipmentLimitSeriesComponent : eqiupment_limit_series_component
VsConverter : equipment_container
VsConverter --> EquipmentContainer : equipment_container
VsConverter : equipment_unavailability_schedule
VsConverter --> EquipmentUnavailabilitySchedule : equipment_unavailability_schedule
VsConverter : faults
VsConverter --> Fault : faults
VsConverter : generic_action
VsConverter --> GenericAction : generic_action
VsConverter : grounding_action
VsConverter --> GroundAction : grounding_action
VsConverter : idc
VsConverter --> CurrentFlow : idc
VsConverter : idle_loss
VsConverter --> ActivePower : idle_loss
VsConverter : in_service
VsConverter : instance_set
VsConverter --> InstanceSet : instance_set
VsConverter : jumping_action
VsConverter --> JumperAction : jumping_action
VsConverter : limit_dependency_model
VsConverter --> LimitDependency : limit_dependency_model
VsConverter : location
VsConverter --> Location : location
VsConverter : m_rid
VsConverter : max_modulation_index
VsConverter : max_p
VsConverter --> ActivePower : max_p
VsConverter : max_udc
VsConverter --> Voltage : max_udc
VsConverter : max_valve_current
VsConverter --> CurrentFlow : max_valve_current
VsConverter : measurements
VsConverter --> Measurement : measurements
VsConverter : min_p
VsConverter --> ActivePower : min_p
VsConverter : min_udc
VsConverter --> Voltage : min_udc
VsConverter : names
VsConverter --> Name : names
VsConverter : network_analysis_enabled
VsConverter : normally_in_service
VsConverter : number_of_valves
VsConverter : operating_share
VsConverter --> OperatingShare : operating_share
VsConverter : operational_limit_set
VsConverter --> OperationalLimitSet : operational_limit_set
VsConverter : operational_restrictions
VsConverter --> OperationalRestriction : operational_restrictions
VsConverter : operational_tags
VsConverter --> OperationalTag : operational_tags
VsConverter : outage
VsConverter --> Outage : outage
VsConverter : outages
VsConverter --> Outage : outages
VsConverter : p
VsConverter --> ActivePower : p
VsConverter : p_pcc_control
VsConverter --> VsPpccControlKind : p_pcc_control
VsConverter : pcc_terminal
VsConverter --> Terminal : pcc_terminal
VsConverter : pin_equipment
VsConverter --> PinEquipment : pin_equipment
VsConverter : pole_loss_p
VsConverter --> ActivePower : pole_loss_p
VsConverter : properties_cimdata_object
VsConverter --> ChangeSetMember : properties_cimdata_object
VsConverter : protection_equipments
VsConverter --> ProtectionEquipment : protection_equipments
VsConverter : protective_action_adjustment
VsConverter --> ProtectiveActionAdjustment : protective_action_adjustment
VsConverter : protective_action_equipment
VsConverter --> ProtectiveActionEquipment : protective_action_equipment
VsConverter : psrevents
VsConverter --> PSREvent : psrevents
VsConverter : psrtype
VsConverter --> PSRType : psrtype
VsConverter : q
VsConverter --> ReactivePower : q
VsConverter : q_pcc_control
VsConverter --> VsQpccControlKind : q_pcc_control
VsConverter : q_share
VsConverter --> PerCent : q_share
VsConverter : rated_udc
VsConverter --> Voltage : rated_udc
VsConverter : reporting_group
VsConverter --> ReportingGroup : reporting_group
VsConverter : resistive_loss
VsConverter --> Resistance : resistive_loss
VsConverter : sv_status
VsConverter --> SvStatus : sv_status
VsConverter : switching_loss
VsConverter --> ActivePowerPerCurrentFlow : switching_loss
VsConverter : target_phase_pcc
VsConverter --> AngleDegrees : target_phase_pcc
VsConverter : target_power_factor_pcc
VsConverter : target_ppcc
VsConverter --> ActivePower : target_ppcc
VsConverter : target_pwmfactor
VsConverter : target_qpcc
VsConverter --> ReactivePower : target_qpcc
VsConverter : target_udc
VsConverter --> Voltage : target_udc
VsConverter : target_upcc
VsConverter --> Voltage : target_upcc
VsConverter : targeting_cimdata_object
VsConverter --> ChangeSetMember : targeting_cimdata_object
VsConverter : terminals
VsConverter --> Terminal : terminals
VsConverter : uc
VsConverter --> Voltage : uc
VsConverter : udc
VsConverter --> Voltage : udc
VsConverter : usage_points
VsConverter --> UsagePoint : usage_points
VsConverter : uv
VsConverter --> Voltage : uv
VsConverter : valve_u
VsConverter --> Voltage : valve_u
VsConverter : verification_action
VsConverter --> VerificationAction : verification_action
VsConverter : vscdynamics
VsConverter --> VSCDynamics : vscdynamics
VsConverter : weather_station
VsConverter --> WeatherStation : weather_station
Inheritance
Slots
| Name | Cardinality and Range | Description | Inheritance |
|---|---|---|---|
| delta | 0..1 AngleDegrees |
Angle between VsConverter | direct |
| droop | 0..1 PU |
Droop constant | direct |
| droop_compensation | 0..1 Resistance |
Compensation constant | direct |
| max_modulation_index | 0..1 Float |
The maximum quotient between the AC converter voltage (Uc) and DC voltage (Ud... | direct |
| max_valve_current | 0..1 CurrentFlow |
The maximum current through a valve | direct |
| p_pcc_control | 0..1 VsPpccControlKind |
Kind of control of real power and/or DC voltage | direct |
| q_pcc_control | 0..1 VsQpccControlKind |
Kind of reactive power control | direct |
| q_share | 0..1 PerCent |
Reactive power sharing factor among parallel converters on Uac control | direct |
| target_phase_pcc | 0..1 AngleDegrees |
Phase target at AC side, at point of common coupling | direct |
| target_power_factor_pcc | 0..1 Float |
Power factor target at the AC side, at point of common coupling | direct |
| target_pwmfactor | 0..1 Float |
Magnitude of pulse-modulation factor | direct |
| target_qpcc | 0..1 ReactivePower |
Reactive power injection target in AC grid, at point of common coupling | direct |
| target_upcc | 0..1 Voltage |
Voltage target in AC grid, at point of common coupling | direct |
| uv | 0..1 Voltage |
Line-to-line voltage on the valve side of the converter transformer | direct |
| capability_curve | 0..1 VsCapabilityCurve |
Capability curve of this converter | direct |
| vscdynamics | 0..1 VSCDynamics |
Voltage source converter dynamics model used to describe dynamic behaviour of... | direct |
| base_s | 0..1 ApparentPower |
Base apparent power of the converter pole | ACDCConverter |
| idc | 0..1 CurrentFlow |
Converter DC current, also called Id | ACDCConverter |
| idle_loss | 0..1 ActivePower |
Active power loss in pole at no power transfer | ACDCConverter |
| max_p | 0..1 ActivePower |
Maximum active power limit | ACDCConverter |
| max_udc | 0..1 Voltage |
The maximum voltage on the DC side at which the converter should operate | ACDCConverter |
| min_p | 0..1 ActivePower |
Minimum active power limit | ACDCConverter |
| min_udc | 0..1 Voltage |
The minimum voltage on the DC side at which the converter should operate | ACDCConverter |
| number_of_valves | 0..1 Integer |
Number of valves in the converter | ACDCConverter |
| p | 0..1 ActivePower |
Active power at the point of common coupling | ACDCConverter |
| pole_loss_p | 0..1 ActivePower |
The active power loss at a DC Pole | |
| ACDCConverter | |||
| q | 0..1 ReactivePower |
Reactive power at the point of common coupling | ACDCConverter |
| rated_udc | 0..1 Voltage |
Rated converter DC voltage, also called UdN | ACDCConverter |
| resistive_loss | 0..1 Resistance |
It is converter’s configuration data used in power flow | ACDCConverter |
| switching_loss | 0..1 ActivePowerPerCurrentFlow |
Switching losses, relative to the base apparent power 'baseS' | ACDCConverter |
| target_ppcc | 0..1 ActivePower |
Real power injection target in AC grid, at point of common coupling | ACDCConverter |
| target_udc | 0..1 Voltage |
Target value for DC voltage magnitude | ACDCConverter |
| uc | 0..1 Voltage |
Line-to-line converter voltage, the voltage at the AC side of the valve | ACDCConverter |
| udc | 0..1 Voltage |
Converter voltage at the DC side, also called Ud | ACDCConverter |
| valve_u | 0..1 Voltage |
Valve threshold voltage, also called Uvalve | ACDCConverter |
| pcc_terminal | 0..1 Terminal |
Point of common coupling terminal for this converter DC side | ACDCConverter |
| dcterminals | 0..* ACDCConverterDCTerminal |
A DC converter have DC converter terminals | ACDCConverter |
| protective_action_adjustment | 0..* ProtectiveActionAdjustment |
The operating condition to the Conducting Equipment is changed when protectiv... | ConductingEquipment |
| sv_status | 0..* SvStatus |
The status state variable associated with this conducting equipment | ConductingEquipment |
| protection_equipments | 0..* ProtectionEquipment |
Protection equipment used to protect specific conducting equipment | ConductingEquipment |
| base_voltage | 0..1 BaseVoltage |
Base voltage of this conducting equipment | ConductingEquipment |
| terminals | 0..* Terminal |
Conducting equipment have terminals that may be connected to other conducting... | ConductingEquipment |
| jumping_action | 0..1 JumperAction |
Jumper action involving jumping operation on this conducting equipment | ConductingEquipment |
| grounding_action | 0..1 GroundAction |
Action involving grounding operation on this conducting equipment | ConductingEquipment |
| outage | 0..1 Outage |
The outage that is isolated by the outage isolation equipment | ConductingEquipment |
| aggregate | 0..1 Boolean |
The aggregate flag provides an alternative way of representing an aggregated ... | Equipment |
| in_service | 0..1 Boolean |
Specifies the availability of the equipment | Equipment |
| network_analysis_enabled | 0..1 Boolean |
The equipment is enabled to participate in network analysis | Equipment |
| normally_in_service | 0..1 Boolean |
Specifies the availability of the equipment under normal operating conditions | Equipment |
| weather_station | 0..* WeatherStation |
Equipment | |
| operational_limit_set | 0..* OperationalLimitSet |
The operational limit sets associated with this equipment | Equipment |
| contingency_equipment | 0..* ContingencyEquipment |
The contingency equipments in which this equipment participates | Equipment |
| equipment_container | 0..1 EquipmentContainer |
Container of this equipment | Equipment |
| faults | 0..* Fault |
All faults on this equipment | Equipment |
| limit_dependency_model | 0..* LimitDependency |
Limit dependencymodels organized under this equipment as a means for organizi... | Equipment |
| eqiupment_limit_series_component | 0..* EquipmentLimitSeriesComponent |
Equipment limit series calculation component to which this equipment contribu... | Equipment |
| protective_action_equipment | 0..* ProtectiveActionEquipment |
Protective action is controlling equipment | Equipment |
| pin_equipment | 0..* PinEquipment |
Equipment | |
| equipment_unavailability_schedule | 0..* EquipmentUnavailabilitySchedule |
Equipment | |
| additional_equipment_container | 0..* EquipmentContainer |
Additional equipment container beyond the primary equipment container | Equipment |
| usage_points | 0..* UsagePoint |
All usage points connected to the electrical grid through this equipment | Equipment |
| outages | 0..* Outage |
All outages in which this equipment is involved | Equipment |
| operational_restrictions | 0..* OperationalRestriction |
All operational restrictions for this equipment | Equipment |
| controls | 0..* Control |
The controller outputs used to actually govern a regulating device, e | PowerSystemResource |
| measurements | 0..* Measurement |
The measurements associated with this power system resource | PowerSystemResource |
| psrtype | 0..1 PSRType |
Custom classification for this power system resource | PowerSystemResource |
| configuration_event | 0..* ConfigurationEvent |
All configuration events created for this Power System resource | PowerSystemResource |
| reporting_group | 0..* ReportingGroup |
Reporting groups to which this power system resource belongs | PowerSystemResource |
| operating_share | 0..* OperatingShare |
The operating shares of this power system resource | PowerSystemResource |
| asset_datasheet | 0..1 AssetInfo |
Datasheet information for this power system resource | PowerSystemResource |
| verification_action | 0..* VerificationAction |
The verification action that is performed on the power system resource | PowerSystemResource |
| clearances | 0..* ClearanceDocument |
All clearances applicable to this power system resource | PowerSystemResource |
| generic_action | 0..* GenericAction |
The generic action that is performed on the power system resource | PowerSystemResource |
| psrevents | 0..* PSREvent |
All events associated with this power system resource | PowerSystemResource |
| assets | 0..* Asset |
All assets represented by this power system resource | PowerSystemResource |
| location | 0..1 Location |
Location of this power system resource | PowerSystemResource |
| operational_tags | 0..* OperationalTag |
All operational tags placed on this power system resource | PowerSystemResource |
| alias_name | 0..1 String |
The aliasName is free text human readable name of the object alternative to I... | IdentifiedObject |
| description | 0..1 String |
The description is a free human readable text describing or naming the object | IdentifiedObject |
| m_rid | 0..1 String |
Master resource identifier issued by a model authority | IdentifiedObject |
| diagram_objects | 0..* DiagramObject |
The diagram objects that are associated with the domain object | IdentifiedObject |
| instance_set | 1..1 InstanceSet |
Dataset containing the data objects | IdentifiedObject |
| names | 0..* Name |
All names of this identified object | IdentifiedObject |
| properties_cimdata_object | 0..1 ChangeSetMember |
The single CIM data object in the appropriate dataset context | IdentifiedObject |
| targeting_cimdata_object | 0..* ChangeSetMember |
Data objects registered | IdentifiedObject |
Usages
| used by | used in | type | used |
|---|---|---|---|
| VsCapabilityCurve | vs_converter_dcsides | range | VsConverter |
| VSCDynamics | vs_converter | range | VsConverter |
| VSCtype1 | vs_converter | range | VsConverter |
| VSCUserDefined | vs_converter | range | VsConverter |
Identifier and Mapping Information
Schema Source
- from schema: https://cim.ucaiug.io/ns#TC57CIM
Mappings
| Mapping Type | Mapped Value |
|---|---|
| self | cim:VsConverter |
| native | cim:VsConverter |
LinkML Source
Direct
name: VsConverter
description: DC side of the voltage source converter (VSC).
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
is_a: ACDCConverter
attributes:
delta:
name: delta
description: Angle between VsConverter.uv and ACDCConverter.uc. It is converter’s
state variable used in power flow. The attribute shall be a positive value or
zero.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:VsConverter.delta
multivalued: false
domain_of:
- VsConverter
range: AngleDegrees
required: false
droop:
name: droop
description: Droop constant. The pu value is obtained as D [kV/MW] x Sb / Ubdc.
The attribute shall be a positive value.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:VsConverter.droop
multivalued: false
domain_of:
- VsConverter
range: PU
required: false
droop_compensation:
name: droop_compensation
description: Compensation constant. Used to compensate for voltage drop when controlling
voltage at a distant bus. The attribute shall be a positive value.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:VsConverter.droopCompensation
multivalued: false
domain_of:
- VsConverter
range: Resistance
required: false
max_modulation_index:
name: max_modulation_index
description: The maximum quotient between the AC converter voltage (Uc) and DC
voltage (Ud). A factor typically less than 1. It is converter’s configuration
data used in power flow.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:VsConverter.maxModulationIndex
multivalued: false
domain_of:
- VsConverter
range: float
required: false
max_valve_current:
name: max_valve_current
description: The maximum current through a valve. It is converter’s configuration
data.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:VsConverter.maxValveCurrent
multivalued: false
domain_of:
- VsConverter
range: CurrentFlow
required: false
p_pcc_control:
name: p_pcc_control
description: Kind of control of real power and/or DC voltage.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:VsConverter.pPccControl
multivalued: false
domain_of:
- VsConverter
- CsConverter
range: VsPpccControlKind
required: false
q_pcc_control:
name: q_pcc_control
description: Kind of reactive power control.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:VsConverter.qPccControl
multivalued: false
domain_of:
- VsConverter
range: VsQpccControlKind
required: false
q_share:
name: q_share
description: Reactive power sharing factor among parallel converters on Uac control.
The attribute shall be a positive value or zero.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:VsConverter.qShare
multivalued: false
domain_of:
- VsConverter
range: PerCent
required: false
target_phase_pcc:
name: target_phase_pcc
description: Phase target at AC side, at point of common coupling. The attribute
shall be a positive value.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:VsConverter.targetPhasePcc
multivalued: false
domain_of:
- VsConverter
range: AngleDegrees
required: false
target_power_factor_pcc:
name: target_power_factor_pcc
description: Power factor target at the AC side, at point of common coupling.
The attribute shall be a positive value.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:VsConverter.targetPowerFactorPcc
multivalued: false
domain_of:
- VsConverter
range: float
required: false
target_pwmfactor:
name: target_pwmfactor
description: Magnitude of pulse-modulation factor. The attribute shall be a positive
value.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:VsConverter.targetPWMfactor
multivalued: false
domain_of:
- VsConverter
range: float
required: false
target_qpcc:
name: target_qpcc
description: Reactive power injection target in AC grid, at point of common coupling. Load
sign convention is used, i.e. positive sign means flow out from a node.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:VsConverter.targetQpcc
multivalued: false
domain_of:
- VsConverter
range: ReactivePower
required: false
target_upcc:
name: target_upcc
description: Voltage target in AC grid, at point of common coupling. The attribute
shall be a positive value.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:VsConverter.targetUpcc
multivalued: false
domain_of:
- VsConverter
range: Voltage
required: false
uv:
name: uv
description: Line-to-line voltage on the valve side of the converter transformer.
It is converter’s state variable, result from power flow. The attribute shall
be a positive value.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:VsConverter.uv
multivalued: false
domain_of:
- VsConverter
range: Voltage
required: false
capability_curve:
name: capability_curve
description: Capability curve of this converter.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:VsConverter.CapabilityCurve
multivalued: false
domain_of:
- VsConverter
range: VsCapabilityCurve
required: false
vscdynamics:
name: vscdynamics
description: Voltage source converter dynamics model used to describe dynamic
behaviour of this converter.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:VsConverter.VSCDynamics
multivalued: false
domain_of:
- VsConverter
range: VSCDynamics
required: false
class_uri: cim:VsConverter
Induced
name: VsConverter
description: DC side of the voltage source converter (VSC).
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
is_a: ACDCConverter
attributes:
delta:
name: delta
description: Angle between VsConverter.uv and ACDCConverter.uc. It is converter’s
state variable used in power flow. The attribute shall be a positive value or
zero.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:VsConverter.delta
multivalued: false
alias: delta
owner: VsConverter
domain_of:
- VsConverter
range: AngleDegrees
required: false
droop:
name: droop
description: Droop constant. The pu value is obtained as D [kV/MW] x Sb / Ubdc.
The attribute shall be a positive value.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:VsConverter.droop
multivalued: false
alias: droop
owner: VsConverter
domain_of:
- VsConverter
range: PU
required: false
droop_compensation:
name: droop_compensation
description: Compensation constant. Used to compensate for voltage drop when controlling
voltage at a distant bus. The attribute shall be a positive value.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:VsConverter.droopCompensation
multivalued: false
alias: droop_compensation
owner: VsConverter
domain_of:
- VsConverter
range: Resistance
required: false
max_modulation_index:
name: max_modulation_index
description: The maximum quotient between the AC converter voltage (Uc) and DC
voltage (Ud). A factor typically less than 1. It is converter’s configuration
data used in power flow.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:VsConverter.maxModulationIndex
multivalued: false
alias: max_modulation_index
owner: VsConverter
domain_of:
- VsConverter
range: float
required: false
max_valve_current:
name: max_valve_current
description: The maximum current through a valve. It is converter’s configuration
data.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:VsConverter.maxValveCurrent
multivalued: false
alias: max_valve_current
owner: VsConverter
domain_of:
- VsConverter
range: CurrentFlow
required: false
p_pcc_control:
name: p_pcc_control
description: Kind of control of real power and/or DC voltage.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:VsConverter.pPccControl
multivalued: false
alias: p_pcc_control
owner: VsConverter
domain_of:
- VsConverter
- CsConverter
range: VsPpccControlKind
required: false
q_pcc_control:
name: q_pcc_control
description: Kind of reactive power control.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:VsConverter.qPccControl
multivalued: false
alias: q_pcc_control
owner: VsConverter
domain_of:
- VsConverter
range: VsQpccControlKind
required: false
q_share:
name: q_share
description: Reactive power sharing factor among parallel converters on Uac control.
The attribute shall be a positive value or zero.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:VsConverter.qShare
multivalued: false
alias: q_share
owner: VsConverter
domain_of:
- VsConverter
range: PerCent
required: false
target_phase_pcc:
name: target_phase_pcc
description: Phase target at AC side, at point of common coupling. The attribute
shall be a positive value.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:VsConverter.targetPhasePcc
multivalued: false
alias: target_phase_pcc
owner: VsConverter
domain_of:
- VsConverter
range: AngleDegrees
required: false
target_power_factor_pcc:
name: target_power_factor_pcc
description: Power factor target at the AC side, at point of common coupling.
The attribute shall be a positive value.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:VsConverter.targetPowerFactorPcc
multivalued: false
alias: target_power_factor_pcc
owner: VsConverter
domain_of:
- VsConverter
range: float
required: false
target_pwmfactor:
name: target_pwmfactor
description: Magnitude of pulse-modulation factor. The attribute shall be a positive
value.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:VsConverter.targetPWMfactor
multivalued: false
alias: target_pwmfactor
owner: VsConverter
domain_of:
- VsConverter
range: float
required: false
target_qpcc:
name: target_qpcc
description: Reactive power injection target in AC grid, at point of common coupling. Load
sign convention is used, i.e. positive sign means flow out from a node.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:VsConverter.targetQpcc
multivalued: false
alias: target_qpcc
owner: VsConverter
domain_of:
- VsConverter
range: ReactivePower
required: false
target_upcc:
name: target_upcc
description: Voltage target in AC grid, at point of common coupling. The attribute
shall be a positive value.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:VsConverter.targetUpcc
multivalued: false
alias: target_upcc
owner: VsConverter
domain_of:
- VsConverter
range: Voltage
required: false
uv:
name: uv
description: Line-to-line voltage on the valve side of the converter transformer.
It is converter’s state variable, result from power flow. The attribute shall
be a positive value.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:VsConverter.uv
multivalued: false
alias: uv
owner: VsConverter
domain_of:
- VsConverter
range: Voltage
required: false
capability_curve:
name: capability_curve
description: Capability curve of this converter.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:VsConverter.CapabilityCurve
multivalued: false
alias: capability_curve
owner: VsConverter
domain_of:
- VsConverter
range: VsCapabilityCurve
required: false
vscdynamics:
name: vscdynamics
description: Voltage source converter dynamics model used to describe dynamic
behaviour of this converter.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:VsConverter.VSCDynamics
multivalued: false
alias: vscdynamics
owner: VsConverter
domain_of:
- VsConverter
range: VSCDynamics
required: false
base_s:
name: base_s
description: Base apparent power of the converter pole. The attribute shall be
a positive value.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ACDCConverter.baseS
multivalued: false
alias: base_s
owner: VsConverter
domain_of:
- ACDCConverter
range: ApparentPower
required: false
idc:
name: idc
description: Converter DC current, also called Id. It is converter’s state variable,
result from power flow.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ACDCConverter.idc
multivalued: false
alias: idc
owner: VsConverter
domain_of:
- ACDCConverter
range: CurrentFlow
required: false
idle_loss:
name: idle_loss
description: Active power loss in pole at no power transfer. It is converter’s
configuration data used in power flow. The attribute shall be a positive value.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ACDCConverter.idleLoss
multivalued: false
alias: idle_loss
owner: VsConverter
domain_of:
- ACDCConverter
range: ActivePower
required: false
max_p:
name: max_p
description: Maximum active power limit. The value is overwritten by values of
VsCapabilityCurve, if present.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:ACDCConverter.maxP
multivalued: false
alias: max_p
owner: VsConverter
domain_of:
- EquivalentInjection
- PowerElectronicsUnit
- ACDCConverter
- FrequencyConverter
- ExternalNetworkInjection
- GeneratorTypeAsset
range: ActivePower
required: false
max_udc:
name: max_udc
description: The maximum voltage on the DC side at which the converter should
operate. It is converter’s configuration data used in power flow. The attribute
shall be a positive value.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ACDCConverter.maxUdc
multivalued: false
alias: max_udc
owner: VsConverter
domain_of:
- ACDCConverter
range: Voltage
required: false
min_p:
name: min_p
description: Minimum active power limit. The value is overwritten by values of
VsCapabilityCurve, if present.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:ACDCConverter.minP
multivalued: false
alias: min_p
owner: VsConverter
domain_of:
- EquivalentInjection
- PowerElectronicsUnit
- ACDCConverter
- FrequencyConverter
- ExternalNetworkInjection
- GeneratorTypeAsset
range: ActivePower
required: false
min_udc:
name: min_udc
description: The minimum voltage on the DC side at which the converter should
operate. It is converter’s configuration data used in power flow. The attribute
shall be a positive value.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ACDCConverter.minUdc
multivalued: false
alias: min_udc
owner: VsConverter
domain_of:
- ACDCConverter
range: Voltage
required: false
number_of_valves:
name: number_of_valves
description: Number of valves in the converter. Used in loss calculations.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ACDCConverter.numberOfValves
multivalued: false
alias: number_of_valves
owner: VsConverter
domain_of:
- ACDCConverter
range: integer
required: false
p:
name: p
description: "Active power at the point of common coupling. Load sign convention\
\ is used, i.e. positive sign means flow out from a node.\r\nStarting value\
\ for a steady state solution in the case a simplified power flow model is used."
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:ACDCConverter.p
multivalued: false
alias: p
owner: VsConverter
domain_of:
- EnergyGroup
- BlockDispatchOrder
- SvPowerFlow
- RotatingMachine
- EquivalentInjection
- PowerElectronicsConnection
- PowerElectronicsConnectionPhase
- ACDCConverter
- EnergyConsumerPhase
- EnergyConsumer
- ExternalNetworkInjection
- GovHydroPID2
- UnderexcLimIEEE2
- UnderexcLim2Simplified
range: ActivePower
required: false
pole_loss_p:
name: pole_loss_p
description: "The active power loss at a DC Pole \r\n= idleLoss + switchingLoss*|Idc|\
\ + resitiveLoss*Idc^2.\r\nFor lossless operation Pdc=Pac.\r\nFor rectifier\
\ operation with losses Pdc=Pac-lossP.\r\nFor inverter operation with losses\
\ Pdc=Pac+lossP.\r\nIt is converter’s state variable used in power flow. The\
\ attribute shall be a positive value."
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ACDCConverter.poleLossP
multivalued: false
alias: pole_loss_p
owner: VsConverter
domain_of:
- ACDCConverter
range: ActivePower
required: false
q:
name: q
description: "Reactive power at the point of common coupling. Load sign convention\
\ is used, i.e. positive sign means flow out from a node.\r\nStarting value\
\ for a steady state solution in the case a simplified power flow model is used."
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:ACDCConverter.q
multivalued: false
alias: q
owner: VsConverter
domain_of:
- SvPowerFlow
- RotatingMachine
- EquivalentInjection
- PowerElectronicsConnection
- PowerElectronicsConnectionPhase
- ACDCConverter
- EnergyConsumerPhase
- EnergyConsumer
- StaticVarCompensator
- ExternalNetworkInjection
- UnderexcLimIEEE2
- UnderexcLim2Simplified
range: ReactivePower
required: false
rated_udc:
name: rated_udc
description: Rated converter DC voltage, also called UdN. The attribute shall
be a positive value. It is converter’s configuration data used in power flow.
For instance a bipolar HVDC link with value 200 kV has a 400kV difference between
the dc lines.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:ACDCConverter.ratedUdc
multivalued: false
alias: rated_udc
owner: VsConverter
domain_of:
- DCConductingEquipment
- ACDCConverter
range: Voltage
required: false
resistive_loss:
name: resistive_loss
description: It is converter’s configuration data used in power flow. Refer to
poleLossP. The attribute shall be a positive value.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ACDCConverter.resistiveLoss
multivalued: false
alias: resistive_loss
owner: VsConverter
domain_of:
- ACDCConverter
range: Resistance
required: false
switching_loss:
name: switching_loss
description: Switching losses, relative to the base apparent power 'baseS'. Refer
to poleLossP. The attribute shall be a positive value.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ACDCConverter.switchingLoss
multivalued: false
alias: switching_loss
owner: VsConverter
domain_of:
- ACDCConverter
range: ActivePowerPerCurrentFlow
required: false
target_ppcc:
name: target_ppcc
description: Real power injection target in AC grid, at point of common coupling. Load
sign convention is used, i.e. positive sign means flow out from a node.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ACDCConverter.targetPpcc
multivalued: false
alias: target_ppcc
owner: VsConverter
domain_of:
- ACDCConverter
range: ActivePower
required: false
target_udc:
name: target_udc
description: Target value for DC voltage magnitude. The attribute shall be a positive
value.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ACDCConverter.targetUdc
multivalued: false
alias: target_udc
owner: VsConverter
domain_of:
- ACDCConverter
range: Voltage
required: false
uc:
name: uc
description: Line-to-line converter voltage, the voltage at the AC side of the
valve. It is converter’s state variable, result from power flow. The attribute
shall be a positive value.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ACDCConverter.uc
multivalued: false
alias: uc
owner: VsConverter
domain_of:
- ACDCConverter
- GovHydroIEEE2
- GovSteamIEEE1
- GovHydro2
- GovHydro4
- GovSteam1
- GovSteamFV3
range: Voltage
required: false
udc:
name: udc
description: Converter voltage at the DC side, also called Ud. It is converter’s
state variable, result from power flow. The attribute shall be a positive value.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ACDCConverter.udc
multivalued: false
alias: udc
owner: VsConverter
domain_of:
- ACDCConverter
range: Voltage
required: false
valve_u:
name: valve_u
description: Valve threshold voltage, also called Uvalve. Forward voltage drop
when the valve is conducting. Used in loss calculations, i.e. the switchLoss
depend on numberOfValves * valveU0.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ACDCConverter.valveU0
multivalued: false
alias: valve_u
owner: VsConverter
domain_of:
- ACDCConverter
range: Voltage
required: false
pcc_terminal:
name: pcc_terminal
description: Point of common coupling terminal for this converter DC side. It
is typically the terminal on the power transformer (or switch) closest to the
AC network.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ACDCConverter.PccTerminal
multivalued: false
alias: pcc_terminal
owner: VsConverter
domain_of:
- ACDCConverter
range: Terminal
required: false
dcterminals:
name: dcterminals
description: A DC converter have DC converter terminals. A converter has two DC
converter terminals.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:ACDCConverter.DCTerminals
multivalued: true
alias: dcterminals
owner: VsConverter
domain_of:
- DCNode
- DCTopologicalNode
- DCConductingEquipment
- ACDCConverter
range: ACDCConverterDCTerminal
required: false
protective_action_adjustment:
name: protective_action_adjustment
description: 'The operating condition to the Conducting Equipment is changed when
protective action adjustment is activated. For ShuntCompensator or other conducting
equipment that operates on discrete values (integer), the values given in float
will be rounded. '
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:ConductingEquipment.ProtectiveActionAdjustment
multivalued: true
alias: protective_action_adjustment
owner: VsConverter
domain_of:
- Measurement
- ConductingEquipment
- DCConductingEquipment
range: ProtectiveActionAdjustment
required: false
sv_status:
name: sv_status
description: The status state variable associated with this conducting equipment.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ConductingEquipment.SvStatus
multivalued: true
alias: sv_status
owner: VsConverter
domain_of:
- ConductingEquipment
range: SvStatus
required: false
protection_equipments:
name: protection_equipments
description: 'Protection equipment used to protect specific conducting equipment. '
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ConductingEquipment.ProtectionEquipments
multivalued: true
alias: protection_equipments
owner: VsConverter
domain_of:
- ConductingEquipment
range: ProtectionEquipment
required: false
base_voltage:
name: base_voltage
description: Base voltage of this conducting equipment. Use only when there is
no voltage level container used and only one base voltage applies. For example,
not used for transformers.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:ConductingEquipment.BaseVoltage
multivalued: false
alias: base_voltage
owner: VsConverter
domain_of:
- TopologicalNode
- TransformerEnd
- ConductingEquipment
- VoltageLevel
- AssetDeployment
range: BaseVoltage
required: false
terminals:
name: terminals
description: Conducting equipment have terminals that may be connected to other
conducting equipment terminals via connectivity nodes or topological nodes.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:ConductingEquipment.Terminals
multivalued: true
alias: terminals
owner: VsConverter
domain_of:
- ConnectivityNode
- ConductingEquipment
range: Terminal
required: false
jumping_action:
name: jumping_action
description: Jumper action involving jumping operation on this conducting equipment.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ConductingEquipment.JumpingAction
multivalued: false
alias: jumping_action
owner: VsConverter
domain_of:
- ConductingEquipment
range: JumperAction
required: false
grounding_action:
name: grounding_action
description: Action involving grounding operation on this conducting equipment.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ConductingEquipment.GroundingAction
multivalued: false
alias: grounding_action
owner: VsConverter
domain_of:
- ConductingEquipment
range: GroundAction
required: false
outage:
name: outage
description: The outage that is isolated by the outage isolation equipment.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:ConductingEquipment.Outage
multivalued: false
alias: outage
owner: VsConverter
domain_of:
- Incident
- SwitchingPlan
- UsagePoint
- ConductingEquipment
- Crew
- EstimatedRestorationTime
- OutageArea
- Fault
range: Outage
required: false
aggregate:
name: aggregate
description: "The aggregate flag provides an alternative way of representing an\
\ aggregated (equivalent) element. It is applicable in cases when the dedicated\
\ classes for equivalent equipment do not have all of the attributes necessary\
\ to represent the required level of detail. In case the flag is set to “true”\
\ the single instance of equipment represents multiple pieces of equipment that\
\ have been modelled together as an aggregate equivalent obtained by a network\
\ reduction procedure. Examples would be power transformers or synchronous machines\
\ operating in parallel modelled as a single aggregate power transformer or\
\ aggregate synchronous machine. \r\nThe attribute is not used for EquivalentBranch,\
\ EquivalentShunt and EquivalentInjection."
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.aggregate
multivalued: false
alias: aggregate
owner: VsConverter
domain_of:
- Equipment
- ReadingType
range: boolean
required: false
in_service:
name: in_service
description: Specifies the availability of the equipment. True means the equipment
is available for topology processing, which determines if the equipment is energized
or not. False means that the equipment is treated by network applications as
if it is not in the model.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.inService
multivalued: false
alias: in_service
owner: VsConverter
domain_of:
- Equipment
- SvStatus
- ProtectiveActionEquipment
range: boolean
required: false
network_analysis_enabled:
name: network_analysis_enabled
description: The equipment is enabled to participate in network analysis. If
unspecified, the value is assumed to be true.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.networkAnalysisEnabled
multivalued: false
alias: network_analysis_enabled
owner: VsConverter
domain_of:
- Equipment
range: boolean
required: false
normally_in_service:
name: normally_in_service
description: Specifies the availability of the equipment under normal operating
conditions. True means the equipment is available for topology processing, which
determines if the equipment is energized or not. False means that the equipment
is treated by network applications as if it is not in the model.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.normallyInService
multivalued: false
alias: normally_in_service
owner: VsConverter
domain_of:
- Equipment
range: boolean
required: false
weather_station:
name: weather_station
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.WeatherStation
multivalued: true
alias: weather_station
owner: VsConverter
domain_of:
- Equipment
range: WeatherStation
required: false
operational_limit_set:
name: operational_limit_set
description: The operational limit sets associated with this equipment.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:Equipment.OperationalLimitSet
multivalued: true
alias: operational_limit_set
owner: VsConverter
domain_of:
- ACDCTerminal
- OperationalLimit
- Equipment
range: OperationalLimitSet
required: false
contingency_equipment:
name: contingency_equipment
description: The contingency equipments in which this equipment participates.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.ContingencyEquipment
multivalued: true
alias: contingency_equipment
owner: VsConverter
domain_of:
- Equipment
range: ContingencyEquipment
required: false
equipment_container:
name: equipment_container
description: Container of this equipment.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.EquipmentContainer
multivalued: false
alias: equipment_container
owner: VsConverter
domain_of:
- Equipment
range: EquipmentContainer
required: false
faults:
name: faults
description: All faults on this equipment.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.Faults
multivalued: true
alias: faults
owner: VsConverter
domain_of:
- Equipment
- Outage
- FaultCauseType
range: Fault
required: false
limit_dependency_model:
name: limit_dependency_model
description: Limit dependencymodels organized under this equipment as a means
for organizing the model in a tree view.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:Equipment.LimitDependencyModel
multivalued: true
alias: limit_dependency_model
owner: VsConverter
domain_of:
- OperationalLimit
- Equipment
range: LimitDependency
required: false
eqiupment_limit_series_component:
name: eqiupment_limit_series_component
description: Equipment limit series calculation component to which this equipment
contributes.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.EqiupmentLimitSeriesComponent
multivalued: true
alias: eqiupment_limit_series_component
owner: VsConverter
domain_of:
- Equipment
range: EquipmentLimitSeriesComponent
required: false
protective_action_equipment:
name: protective_action_equipment
description: Protective action is controlling equipment. This can be direct signals
from the control center, or emulation of action done by protection equipment.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.ProtectiveActionEquipment
multivalued: true
alias: protective_action_equipment
owner: VsConverter
domain_of:
- Equipment
range: ProtectiveActionEquipment
required: false
pin_equipment:
name: pin_equipment
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.PinEquipment
multivalued: true
alias: pin_equipment
owner: VsConverter
domain_of:
- Equipment
range: PinEquipment
required: false
equipment_unavailability_schedule:
name: equipment_unavailability_schedule
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.EquipmentUnavailabilitySchedule
multivalued: true
alias: equipment_unavailability_schedule
owner: VsConverter
domain_of:
- Equipment
- UnavailabilitySwitchAction
- UnavailablitySchedule
range: EquipmentUnavailabilitySchedule
required: false
additional_equipment_container:
name: additional_equipment_container
description: Additional equipment container beyond the primary equipment container. The
equipment is contained in another equipment container, but also grouped with
this equipment container.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.AdditionalEquipmentContainer
multivalued: true
alias: additional_equipment_container
owner: VsConverter
domain_of:
- Equipment
range: EquipmentContainer
required: false
usage_points:
name: usage_points
description: All usage points connected to the electrical grid through this equipment.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.UsagePoints
multivalued: true
alias: usage_points
owner: VsConverter
domain_of:
- Equipment
- CustomerAgreement
- ServiceCategory
- PricingStructure
- EndDeviceControl
- UsagePointGroup
- ServiceLocation
- MetrologyRequirement
- ServiceSupplier
- UsagePointLocation
range: UsagePoint
required: false
outages:
name: outages
description: All outages in which this equipment is involved.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.Outages
multivalued: true
alias: outages
owner: VsConverter
domain_of:
- Equipment
range: Outage
required: false
operational_restrictions:
name: operational_restrictions
description: All operational restrictions for this equipment.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.OperationalRestrictions
multivalued: true
alias: operational_restrictions
owner: VsConverter
domain_of:
- Equipment
- ProductAssetModel
range: OperationalRestriction
required: false
controls:
name: controls
description: The controller outputs used to actually govern a regulating device,
e.g. the magnetization of a synchronous machine or capacitor bank breaker actuator.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.Controls
multivalued: true
alias: controls
owner: VsConverter
domain_of:
- PowerSystemResource
- HostControlArea
range: Control
required: false
measurements:
name: measurements
description: The measurements associated with this power system resource.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.Measurements
multivalued: true
alias: measurements
owner: VsConverter
domain_of:
- PowerSystemResource
- ACDCTerminal
- Asset
- Location
- Procedure
- AnalogLimitSet
- AccumulatorLimitSet
range: Measurement
required: false
psrtype:
name: psrtype
description: Custom classification for this power system resource.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.PSRType
multivalued: false
alias: psrtype
owner: VsConverter
domain_of:
- PowerSystemResource
range: PSRType
required: false
configuration_event:
name: configuration_event
description: All configuration events created for this Power System resource.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.ConfigurationEvent
multivalued: true
alias: configuration_event
owner: VsConverter
domain_of:
- PowerSystemResource
- FaultCauseType
range: ConfigurationEvent
required: false
reporting_group:
name: reporting_group
description: Reporting groups to which this power system resource belongs.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.ReportingGroup
multivalued: true
alias: reporting_group
owner: VsConverter
domain_of:
- PowerSystemResource
- BusNameMarker
- TopologicalNode
- ReportingSuperGroup
range: ReportingGroup
required: false
operating_share:
name: operating_share
description: The operating shares of this power system resource.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.OperatingShare
multivalued: true
alias: operating_share
owner: VsConverter
domain_of:
- PowerSystemResource
- OperatingParticipant
range: OperatingShare
required: false
asset_datasheet:
name: asset_datasheet
description: Datasheet information for this power system resource.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.AssetDatasheet
multivalued: false
alias: asset_datasheet
owner: VsConverter
domain_of:
- PowerSystemResource
range: AssetInfo
required: false
verification_action:
name: verification_action
description: The verification action that is performed on the power system resource
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.VerificationAction
multivalued: true
alias: verification_action
owner: VsConverter
domain_of:
- PowerSystemResource
range: VerificationAction
required: false
clearances:
name: clearances
description: All clearances applicable to this power system resource.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.Clearances
multivalued: true
alias: clearances
owner: VsConverter
domain_of:
- PowerSystemResource
range: ClearanceDocument
required: false
generic_action:
name: generic_action
description: The generic action that is performed on the power system resource
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.GenericAction
multivalued: true
alias: generic_action
owner: VsConverter
domain_of:
- PowerSystemResource
range: GenericAction
required: false
psrevents:
name: psrevents
description: All events associated with this power system resource.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.PSREvents
multivalued: true
alias: psrevents
owner: VsConverter
domain_of:
- PowerSystemResource
range: PSREvent
required: false
assets:
name: assets
description: All assets represented by this power system resource. For example,
multiple conductor assets are electrically modelled as a single AC line segment.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.Assets
multivalued: true
alias: assets
owner: VsConverter
domain_of:
- PowerSystemResource
- AssetInfo
- Location
- WorkTask
- ErpRecDelvLineItem
- AssetContainer
- ActivityRecord
- Procedure
- ReliabilityInfo
- AssetPropertyCurve
- AssetOrganisationRole
- ScheduledEvent
range: Asset
required: false
location:
name: location
description: Location of this power system resource.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.Location
multivalued: false
alias: location
owner: VsConverter
domain_of:
- PowerSystemResource
- Asset
- Incident
- SwitchingOrder
- TroubleOrder
- Crew
- Fault
- PointOfSale
- TroubleTicket
- OutageOrder
- EnvironmentalMonitoringStation
- EnvironmentalLocationType
- PositionPoint
- FailureEvent
range: Location
required: false
operational_tags:
name: operational_tags
description: All operational tags placed on this power system resource.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.OperationalTags
multivalued: true
alias: operational_tags
owner: VsConverter
domain_of:
- PowerSystemResource
- Asset
range: OperationalTag
required: false
alias_name:
name: alias_name
description: "The aliasName is free text human readable name of the object alternative\
\ to IdentifiedObject.name. It may be non unique and may not correlate to a\
\ naming hierarchy.\r\nThe attribute aliasName is retained because of backwards\
\ compatibility between CIM relases. It is however recommended to replace aliasName\
\ with the Name class as aliasName is planned for retirement at a future time.\r\
\n\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.aliasName
multivalued: false
alias: alias_name
owner: VsConverter
domain_of:
- IdentifiedObject
range: string
required: false
description:
name: description
description: The description is a free human readable text describing or naming
the object. It may be non unique and may not correlate to a naming hierarchy.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.description
multivalued: false
alias: description
owner: VsConverter
domain_of:
- IdentifiedObject
- NameType
- NameTypeAuthority
- DataSet
- SwitchingStepGroup
- AreaReserveSpec
range: string
required: false
m_rid:
name: m_rid
description: "Master resource identifier issued by a model authority. The mRID\
\ is unique within an exchange context. Global uniqueness is easily achieved\
\ by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is\
\ strongly recommended.\r\nFor CIMXML data files in RDF syntax conforming to\
\ IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify\
\ CIM object elements."
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.mRID
multivalued: false
alias: m_rid
owner: VsConverter
domain_of:
- IdentifiedObject
- DataSet
range: string
required: false
diagram_objects:
name: diagram_objects
description: The diagram objects that are associated with the domain object.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.DiagramObjects
multivalued: true
alias: diagram_objects
owner: VsConverter
domain_of:
- IdentifiedObject
range: DiagramObject
required: false
instance_set:
name: instance_set
description: Dataset containing the data objects.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.InstanceSet
multivalued: false
alias: instance_set
owner: VsConverter
domain_of:
- IdentifiedObject
range: InstanceSet
required: true
names:
name: names
description: All names of this identified object.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.Names
multivalued: true
alias: names
owner: VsConverter
domain_of:
- IdentifiedObject
- NameType
range: Name
required: false
properties_cimdata_object:
name: properties_cimdata_object
description: The single CIM data object in the appropriate dataset context.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.PropertiesCIMDataObject
multivalued: false
alias: properties_cimdata_object
owner: VsConverter
domain_of:
- IdentifiedObject
range: ChangeSetMember
required: false
targeting_cimdata_object:
name: targeting_cimdata_object
description: Data objects registered.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.TargetingCIMDataObject
multivalued: true
alias: targeting_cimdata_object
owner: VsConverter
domain_of:
- IdentifiedObject
range: ChangeSetMember
required: false
class_uri: cim:VsConverter