Class: TransformerMeshImpedance
_Transformer mesh impedance (Delta-model) between transformer ends. _
The typical case is that this class describes the impedance between two transformer ends pair-wise, i.e. the cardinalities at both transformer end associations are 1. However, in cases where two or more transformer ends are modelled the cardinalities are larger than 1.
URI: cim:TransformerMeshImpedance
classDiagram
class TransformerMeshImpedance
IdentifiedObject <|-- TransformerMeshImpedance
TransformerMeshImpedance : alias_name
TransformerMeshImpedance : description
TransformerMeshImpedance : diagram_objects
TransformerMeshImpedance --> DiagramObject : diagram_objects
TransformerMeshImpedance : from_transformer_end
TransformerMeshImpedance --> TransformerEnd : from_transformer_end
TransformerMeshImpedance : from_transformer_end_info
TransformerMeshImpedance --> TransformerEndInfo : from_transformer_end_info
TransformerMeshImpedance : instance_set
TransformerMeshImpedance --> InstanceSet : instance_set
TransformerMeshImpedance : m_rid
TransformerMeshImpedance : names
TransformerMeshImpedance --> Name : names
TransformerMeshImpedance : properties_cimdata_object
TransformerMeshImpedance --> ChangeSetMember : properties_cimdata_object
TransformerMeshImpedance : r
TransformerMeshImpedance --> Resistance : r
TransformerMeshImpedance : targeting_cimdata_object
TransformerMeshImpedance --> ChangeSetMember : targeting_cimdata_object
TransformerMeshImpedance : to_transformer_end
TransformerMeshImpedance --> TransformerEnd : to_transformer_end
TransformerMeshImpedance : to_transformer_end_infos
TransformerMeshImpedance --> TransformerEndInfo : to_transformer_end_infos
TransformerMeshImpedance : x
TransformerMeshImpedance --> Reactance : x
Inheritance
- IdentifiedObject
- TransformerMeshImpedance
Slots
| Name | Cardinality and Range | Description | Inheritance |
|---|---|---|---|
| r | 0..1 Resistance |
Zero-sequence resistance between the 'from' and the 'to' end, seen from the '... | direct |
| x | 0..1 Reactance |
Zero-sequence reactance between the 'from' and the 'to' end, seen from the 'f... | direct |
| to_transformer_end | 1..* TransformerEnd |
All transformer ends this mesh impedance is connected to | direct |
| from_transformer_end | 1..1 TransformerEnd |
From end this mesh impedance is connected to | direct |
| to_transformer_end_infos | 0..* TransformerEndInfo |
All 'to' transformer end datasheets this mesh impedance for 'from' transforme... | direct |
| from_transformer_end_info | 0..1 TransformerEndInfo |
'from' transformer end datasheet this mesh impedance is calculated from | direct |
| alias_name | 0..1 String |
The aliasName is free text human readable name of the object alternative to I... | IdentifiedObject |
| description | 0..1 String |
The description is a free human readable text describing or naming the object | IdentifiedObject |
| m_rid | 0..1 String |
Master resource identifier issued by a model authority | IdentifiedObject |
| diagram_objects | 0..* DiagramObject |
The diagram objects that are associated with the domain object | IdentifiedObject |
| instance_set | 1..1 InstanceSet |
Dataset containing the data objects | IdentifiedObject |
| names | 0..* Name |
All names of this identified object | IdentifiedObject |
| properties_cimdata_object | 0..1 ChangeSetMember |
The single CIM data object in the appropriate dataset context | IdentifiedObject |
| targeting_cimdata_object | 0..* ChangeSetMember |
Data objects registered | IdentifiedObject |
Usages
Identifier and Mapping Information
Schema Source
- from schema: https://cim.ucaiug.io/ns#TC57CIM
Mappings
| Mapping Type | Mapped Value |
|---|---|
| self | cim:TransformerMeshImpedance |
| native | cim:TransformerMeshImpedance |
LinkML Source
Direct
name: TransformerMeshImpedance
description: "Transformer mesh impedance (Delta-model) between transformer ends.\r\
\nThe typical case is that this class describes the impedance between two transformer\
\ ends pair-wise, i.e. the cardinalities at both transformer end associations are\
\ 1. However, in cases where two or more transformer ends are modelled the cardinalities\
\ are larger than 1."
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
is_a: IdentifiedObject
attributes:
r:
name: r
description: "Zero-sequence resistance between the 'from' and the 'to' end, seen\
\ from the 'from' end.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:TransformerMeshImpedance.r0
multivalued: false
domain_of:
- MutualCoupling
- TransformerMeshImpedance
- TransformerEndInfo
- PowerTransformerEnd
- ACLineSegment
- SynchronousMachine
- EquivalentInjection
- PowerElectronicsConnection
- SeriesCompensator
- TransformerStarImpedance
- TapChangerTablePoint
- PerLengthSequenceImpedance
- PhaseImpedanceData
- EarthFaultCompensator
- EnergySource
- EquivalentBranch
- DCGround
- GovCT1
- GovCT2
- GovGAST
- GovGAST1
- GovHydroDD
- GovHydroPID
- GovHydroR
- GovSteam0
- GovSteamFV2
- ExcNI
- UnderexcLimX2
range: Resistance
required: false
x:
name: x
description: "Zero-sequence reactance between the 'from' and the 'to' end, seen\
\ from the 'from' end.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:TransformerMeshImpedance.x0
multivalued: false
domain_of:
- MutualCoupling
- TransformerMeshImpedance
- PowerTransformerEnd
- ACLineSegment
- SynchronousMachine
- EquivalentInjection
- PowerElectronicsConnection
- SeriesCompensator
- TransformerStarImpedance
- TapChangerTablePoint
- PerLengthSequenceImpedance
- PhaseImpedanceData
- GroundingImpedance
- EnergySource
- EquivalentBranch
- GovGAST2
range: Reactance
required: false
to_transformer_end:
name: to_transformer_end
description: All transformer ends this mesh impedance is connected to.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:TransformerMeshImpedance.ToTransformerEnd
multivalued: true
domain_of:
- TransformerMeshImpedance
range: TransformerEnd
required: true
from_transformer_end:
name: from_transformer_end
description: From end this mesh impedance is connected to. It determines the voltage
reference.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:TransformerMeshImpedance.FromTransformerEnd
multivalued: false
domain_of:
- TransformerMeshImpedance
range: TransformerEnd
required: true
to_transformer_end_infos:
name: to_transformer_end_infos
description: All 'to' transformer end datasheets this mesh impedance for 'from'
transformer end is calculated from.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:TransformerMeshImpedance.ToTransformerEndInfos
multivalued: true
domain_of:
- TransformerMeshImpedance
range: TransformerEndInfo
required: false
from_transformer_end_info:
name: from_transformer_end_info
description: '''from'' transformer end datasheet this mesh impedance is calculated
from. It determines the voltage reference.'
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:TransformerMeshImpedance.FromTransformerEndInfo
multivalued: false
domain_of:
- TransformerMeshImpedance
range: TransformerEndInfo
required: false
class_uri: cim:TransformerMeshImpedance
Induced
name: TransformerMeshImpedance
description: "Transformer mesh impedance (Delta-model) between transformer ends.\r\
\nThe typical case is that this class describes the impedance between two transformer\
\ ends pair-wise, i.e. the cardinalities at both transformer end associations are\
\ 1. However, in cases where two or more transformer ends are modelled the cardinalities\
\ are larger than 1."
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
is_a: IdentifiedObject
attributes:
r:
name: r
description: "Zero-sequence resistance between the 'from' and the 'to' end, seen\
\ from the 'from' end.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:TransformerMeshImpedance.r0
multivalued: false
alias: r
owner: TransformerMeshImpedance
domain_of:
- MutualCoupling
- TransformerMeshImpedance
- TransformerEndInfo
- PowerTransformerEnd
- ACLineSegment
- SynchronousMachine
- EquivalentInjection
- PowerElectronicsConnection
- SeriesCompensator
- TransformerStarImpedance
- TapChangerTablePoint
- PerLengthSequenceImpedance
- PhaseImpedanceData
- EarthFaultCompensator
- EnergySource
- EquivalentBranch
- DCGround
- GovCT1
- GovCT2
- GovGAST
- GovGAST1
- GovHydroDD
- GovHydroPID
- GovHydroR
- GovSteam0
- GovSteamFV2
- ExcNI
- UnderexcLimX2
range: Resistance
required: false
x:
name: x
description: "Zero-sequence reactance between the 'from' and the 'to' end, seen\
\ from the 'from' end.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:TransformerMeshImpedance.x0
multivalued: false
alias: x
owner: TransformerMeshImpedance
domain_of:
- MutualCoupling
- TransformerMeshImpedance
- PowerTransformerEnd
- ACLineSegment
- SynchronousMachine
- EquivalentInjection
- PowerElectronicsConnection
- SeriesCompensator
- TransformerStarImpedance
- TapChangerTablePoint
- PerLengthSequenceImpedance
- PhaseImpedanceData
- GroundingImpedance
- EnergySource
- EquivalentBranch
- GovGAST2
range: Reactance
required: false
to_transformer_end:
name: to_transformer_end
description: All transformer ends this mesh impedance is connected to.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:TransformerMeshImpedance.ToTransformerEnd
multivalued: true
alias: to_transformer_end
owner: TransformerMeshImpedance
domain_of:
- TransformerMeshImpedance
range: TransformerEnd
required: true
from_transformer_end:
name: from_transformer_end
description: From end this mesh impedance is connected to. It determines the voltage
reference.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:TransformerMeshImpedance.FromTransformerEnd
multivalued: false
alias: from_transformer_end
owner: TransformerMeshImpedance
domain_of:
- TransformerMeshImpedance
range: TransformerEnd
required: true
to_transformer_end_infos:
name: to_transformer_end_infos
description: All 'to' transformer end datasheets this mesh impedance for 'from'
transformer end is calculated from.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:TransformerMeshImpedance.ToTransformerEndInfos
multivalued: true
alias: to_transformer_end_infos
owner: TransformerMeshImpedance
domain_of:
- TransformerMeshImpedance
range: TransformerEndInfo
required: false
from_transformer_end_info:
name: from_transformer_end_info
description: '''from'' transformer end datasheet this mesh impedance is calculated
from. It determines the voltage reference.'
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:TransformerMeshImpedance.FromTransformerEndInfo
multivalued: false
alias: from_transformer_end_info
owner: TransformerMeshImpedance
domain_of:
- TransformerMeshImpedance
range: TransformerEndInfo
required: false
alias_name:
name: alias_name
description: "The aliasName is free text human readable name of the object alternative\
\ to IdentifiedObject.name. It may be non unique and may not correlate to a\
\ naming hierarchy.\r\nThe attribute aliasName is retained because of backwards\
\ compatibility between CIM relases. It is however recommended to replace aliasName\
\ with the Name class as aliasName is planned for retirement at a future time.\r\
\n\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.aliasName
multivalued: false
alias: alias_name
owner: TransformerMeshImpedance
domain_of:
- IdentifiedObject
range: string
required: false
description:
name: description
description: The description is a free human readable text describing or naming
the object. It may be non unique and may not correlate to a naming hierarchy.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.description
multivalued: false
alias: description
owner: TransformerMeshImpedance
domain_of:
- IdentifiedObject
- NameType
- NameTypeAuthority
- DataSet
- SwitchingStepGroup
- AreaReserveSpec
range: string
required: false
m_rid:
name: m_rid
description: "Master resource identifier issued by a model authority. The mRID\
\ is unique within an exchange context. Global uniqueness is easily achieved\
\ by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is\
\ strongly recommended.\r\nFor CIMXML data files in RDF syntax conforming to\
\ IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify\
\ CIM object elements."
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.mRID
multivalued: false
alias: m_rid
owner: TransformerMeshImpedance
domain_of:
- IdentifiedObject
- DataSet
range: string
required: false
diagram_objects:
name: diagram_objects
description: The diagram objects that are associated with the domain object.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.DiagramObjects
multivalued: true
alias: diagram_objects
owner: TransformerMeshImpedance
domain_of:
- IdentifiedObject
range: DiagramObject
required: false
instance_set:
name: instance_set
description: Dataset containing the data objects.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.InstanceSet
multivalued: false
alias: instance_set
owner: TransformerMeshImpedance
domain_of:
- IdentifiedObject
range: InstanceSet
required: true
names:
name: names
description: All names of this identified object.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.Names
multivalued: true
alias: names
owner: TransformerMeshImpedance
domain_of:
- IdentifiedObject
- NameType
range: Name
required: false
properties_cimdata_object:
name: properties_cimdata_object
description: The single CIM data object in the appropriate dataset context.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.PropertiesCIMDataObject
multivalued: false
alias: properties_cimdata_object
owner: TransformerMeshImpedance
domain_of:
- IdentifiedObject
range: ChangeSetMember
required: false
targeting_cimdata_object:
name: targeting_cimdata_object
description: Data objects registered.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.TargetingCIMDataObject
multivalued: true
alias: targeting_cimdata_object
owner: TransformerMeshImpedance
domain_of:
- IdentifiedObject
range: ChangeSetMember
required: false
class_uri: cim:TransformerMeshImpedance