Skip to content

Class: SynchronousMachineUserDefined

Synchronous machine whose dynamic behaviour is described by a user-defined model.

URI: cim:SynchronousMachineUserDefined

 classDiagram
    class SynchronousMachineUserDefined
      SynchronousMachineDynamics <|-- SynchronousMachineUserDefined

      SynchronousMachineUserDefined : alias_name

      SynchronousMachineUserDefined : cross_compound_turbine_governor_dyanmics

          SynchronousMachineUserDefined --> CrossCompoundTurbineGovernorDynamics : cross_compound_turbine_governor_dyanmics

      SynchronousMachineUserDefined : cross_compound_turbine_governor_dynamics

          SynchronousMachineUserDefined --> CrossCompoundTurbineGovernorDynamics : cross_compound_turbine_governor_dynamics

      SynchronousMachineUserDefined : damping

      SynchronousMachineUserDefined : description

      SynchronousMachineUserDefined : diagram_objects

          SynchronousMachineUserDefined --> DiagramObject : diagram_objects

      SynchronousMachineUserDefined : enabled

      SynchronousMachineUserDefined : excitation_system_dynamics

          SynchronousMachineUserDefined --> ExcitationSystemDynamics : excitation_system_dynamics

      SynchronousMachineUserDefined : gen_icompensation_for_gen_j

          SynchronousMachineUserDefined --> GenICompensationForGenJ : gen_icompensation_for_gen_j

      SynchronousMachineUserDefined : inertia

          SynchronousMachineUserDefined --> Seconds : inertia

      SynchronousMachineUserDefined : instance_set

          SynchronousMachineUserDefined --> InstanceSet : instance_set

      SynchronousMachineUserDefined : m_rid

      SynchronousMachineUserDefined : mechanical_load_dynamics

          SynchronousMachineUserDefined --> MechanicalLoadDynamics : mechanical_load_dynamics

      SynchronousMachineUserDefined : names

          SynchronousMachineUserDefined --> Name : names

      SynchronousMachineUserDefined : properties_cimdata_object

          SynchronousMachineUserDefined --> ChangeSetMember : properties_cimdata_object

      SynchronousMachineUserDefined : proprietary

      SynchronousMachineUserDefined : proprietary_parameter_dynamics

          SynchronousMachineUserDefined --> ProprietaryParameterDynamics : proprietary_parameter_dynamics

      SynchronousMachineUserDefined : saturation_factor

      SynchronousMachineUserDefined : stator_leakage_reactance

          SynchronousMachineUserDefined --> PU : stator_leakage_reactance

      SynchronousMachineUserDefined : stator_resistance

          SynchronousMachineUserDefined --> PU : stator_resistance

      SynchronousMachineUserDefined : synchronous_machine

          SynchronousMachineUserDefined --> SynchronousMachine : synchronous_machine

      SynchronousMachineUserDefined : targeting_cimdata_object

          SynchronousMachineUserDefined --> ChangeSetMember : targeting_cimdata_object

      SynchronousMachineUserDefined : turbine_governor_dynamics

          SynchronousMachineUserDefined --> TurbineGovernorDynamics : turbine_governor_dynamics

Inheritance

Slots

Name Cardinality and Range Description Inheritance
proprietary 0..1
Boolean
Behaviour is based on a proprietary model as opposed to a detailed model direct
proprietary_parameter_dynamics 0..*
ProprietaryParameterDynamics
Parameter of this proprietary user-defined model direct
synchronous_machine 1..1
SynchronousMachine
Synchronous machine to which synchronous machine dynamics model applies SynchronousMachineDynamics
turbine_governor_dynamics 0..*
TurbineGovernorDynamics
Turbine-governor model associated with this synchronous machine model SynchronousMachineDynamics
gen_icompensation_for_gen_j 0..*
GenICompensationForGenJ
Compensation of voltage compensator's generator for current flow out of this ... SynchronousMachineDynamics
excitation_system_dynamics 0..1
ExcitationSystemDynamics
Excitation system model associated with this synchronous machine model SynchronousMachineDynamics
cross_compound_turbine_governor_dynamics 0..1
CrossCompoundTurbineGovernorDynamics
The cross-compound turbine governor with which this low-pressure synchronous ... SynchronousMachineDynamics
cross_compound_turbine_governor_dyanmics 0..1
CrossCompoundTurbineGovernorDynamics
The cross-compound turbine governor with which this high-pressure synchronous... SynchronousMachineDynamics
mechanical_load_dynamics 0..1
MechanicalLoadDynamics
Mechanical load model associated with this synchronous machine model SynchronousMachineDynamics
damping 0..1
Float
Damping torque coefficient (D) (>= 0) RotatingMachineDynamics
inertia 0..1
Seconds
Inertia constant of generator or motor and mechanical load (H) (> 0... RotatingMachineDynamics
saturation_factor 0..1
Float
Saturation factor at 120% of rated terminal voltage (S12) (>= Rotat... RotatingMachineDynamics
stator_leakage_reactance 0..1
PU
Stator leakage reactance (Xl) (>= 0) RotatingMachineDynamics
stator_resistance 0..1
PU
Stator (armature) resistance (Rs) (>= 0) RotatingMachineDynamics
enabled 0..1
Boolean
Function block used indicator DynamicsFunctionBlock
alias_name 0..1
String
The aliasName is free text human readable name of the object alternative to I... IdentifiedObject
description 0..1
String
The description is a free human readable text describing or naming the object IdentifiedObject
m_rid 0..1
String
Master resource identifier issued by a model authority IdentifiedObject
diagram_objects 0..*
DiagramObject
The diagram objects that are associated with the domain object IdentifiedObject
instance_set 1..1
InstanceSet
Dataset containing the data objects IdentifiedObject
names 0..*
Name
All names of this identified object IdentifiedObject
properties_cimdata_object 0..1
ChangeSetMember
The single CIM data object in the appropriate dataset context IdentifiedObject
targeting_cimdata_object 0..*
ChangeSetMember
Data objects registered IdentifiedObject

Usages

used by used in type used
ProprietaryParameterDynamics synchronous_machine_user_defined range SynchronousMachineUserDefined

Identifier and Mapping Information

Schema Source

  • from schema: https://cim.ucaiug.io/ns#TC57CIM

Mappings

Mapping Type Mapped Value
self cim:SynchronousMachineUserDefined
native cim:SynchronousMachineUserDefined

LinkML Source

Direct

name: SynchronousMachineUserDefined
description: Synchronous machine whose dynamic behaviour is described by a user-defined
  model.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
is_a: SynchronousMachineDynamics
attributes:
  proprietary:
    name: proprietary
    description: "Behaviour is based on a proprietary model as opposed to a detailed\
      \ model.\r\ntrue = user-defined model is proprietary with behaviour mutually\
      \ understood by sending and receiving applications and parameters passed as\
      \ general attributes\r\nfalse = user-defined model is explicitly defined in\
      \ terms of control blocks and their input and output signals."
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:SynchronousMachineUserDefined.proprietary
    multivalued: false
    domain_of:
    - SynchronousMachineUserDefined
    - SVCUserDefined
    - VSCUserDefined
    - CSCUserDefined
    - WindPlantUserDefined
    - WindType3or4UserDefined
    - WindType1or2UserDefined
    - LoadUserDefined
    - VoltageCompensatorUserDefined
    - PFVArControllerType2UserDefined
    - VoltageAdjusterUserDefined
    - PFVArControllerType1UserDefined
    - DiscontinuousExcitationControlUserDefined
    - PowerSystemStabilizerUserDefined
    - UnderexcitationLimiterUserDefined
    - OverexcitationLimiterUserDefined
    - ExcitationSystemUserDefined
    - MechanicalLoadUserDefined
    - TurbineLoadControllerUserDefined
    - TurbineGovernorUserDefined
    - AsynchronousMachineUserDefined
    range: boolean
    required: false
  proprietary_parameter_dynamics:
    name: proprietary_parameter_dynamics
    description: Parameter of this proprietary user-defined model.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:SynchronousMachineUserDefined.ProprietaryParameterDynamics
    multivalued: true
    domain_of:
    - SynchronousMachineUserDefined
    - SVCUserDefined
    - VSCUserDefined
    - CSCUserDefined
    - WindPlantUserDefined
    - WindType3or4UserDefined
    - WindType1or2UserDefined
    - LoadUserDefined
    - VoltageCompensatorUserDefined
    - PFVArControllerType2UserDefined
    - VoltageAdjusterUserDefined
    - PFVArControllerType1UserDefined
    - DiscontinuousExcitationControlUserDefined
    - PowerSystemStabilizerUserDefined
    - UnderexcitationLimiterUserDefined
    - OverexcitationLimiterUserDefined
    - ExcitationSystemUserDefined
    - MechanicalLoadUserDefined
    - TurbineLoadControllerUserDefined
    - TurbineGovernorUserDefined
    - AsynchronousMachineUserDefined
    range: ProprietaryParameterDynamics
    required: false
class_uri: cim:SynchronousMachineUserDefined

Induced

name: SynchronousMachineUserDefined
description: Synchronous machine whose dynamic behaviour is described by a user-defined
  model.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
is_a: SynchronousMachineDynamics
attributes:
  proprietary:
    name: proprietary
    description: "Behaviour is based on a proprietary model as opposed to a detailed\
      \ model.\r\ntrue = user-defined model is proprietary with behaviour mutually\
      \ understood by sending and receiving applications and parameters passed as\
      \ general attributes\r\nfalse = user-defined model is explicitly defined in\
      \ terms of control blocks and their input and output signals."
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:SynchronousMachineUserDefined.proprietary
    multivalued: false
    alias: proprietary
    owner: SynchronousMachineUserDefined
    domain_of:
    - SynchronousMachineUserDefined
    - SVCUserDefined
    - VSCUserDefined
    - CSCUserDefined
    - WindPlantUserDefined
    - WindType3or4UserDefined
    - WindType1or2UserDefined
    - LoadUserDefined
    - VoltageCompensatorUserDefined
    - PFVArControllerType2UserDefined
    - VoltageAdjusterUserDefined
    - PFVArControllerType1UserDefined
    - DiscontinuousExcitationControlUserDefined
    - PowerSystemStabilizerUserDefined
    - UnderexcitationLimiterUserDefined
    - OverexcitationLimiterUserDefined
    - ExcitationSystemUserDefined
    - MechanicalLoadUserDefined
    - TurbineLoadControllerUserDefined
    - TurbineGovernorUserDefined
    - AsynchronousMachineUserDefined
    range: boolean
    required: false
  proprietary_parameter_dynamics:
    name: proprietary_parameter_dynamics
    description: Parameter of this proprietary user-defined model.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:SynchronousMachineUserDefined.ProprietaryParameterDynamics
    multivalued: true
    alias: proprietary_parameter_dynamics
    owner: SynchronousMachineUserDefined
    domain_of:
    - SynchronousMachineUserDefined
    - SVCUserDefined
    - VSCUserDefined
    - CSCUserDefined
    - WindPlantUserDefined
    - WindType3or4UserDefined
    - WindType1or2UserDefined
    - LoadUserDefined
    - VoltageCompensatorUserDefined
    - PFVArControllerType2UserDefined
    - VoltageAdjusterUserDefined
    - PFVArControllerType1UserDefined
    - DiscontinuousExcitationControlUserDefined
    - PowerSystemStabilizerUserDefined
    - UnderexcitationLimiterUserDefined
    - OverexcitationLimiterUserDefined
    - ExcitationSystemUserDefined
    - MechanicalLoadUserDefined
    - TurbineLoadControllerUserDefined
    - TurbineGovernorUserDefined
    - AsynchronousMachineUserDefined
    range: ProprietaryParameterDynamics
    required: false
  synchronous_machine:
    name: synchronous_machine
    description: Synchronous machine to which synchronous machine dynamics model applies.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:SynchronousMachineDynamics.SynchronousMachine
    multivalued: false
    alias: synchronous_machine
    owner: SynchronousMachineUserDefined
    domain_of:
    - SynchronousMachineDynamics
    range: SynchronousMachine
    required: true
  turbine_governor_dynamics:
    name: turbine_governor_dynamics
    description: Turbine-governor model associated with this synchronous machine model.
      Multiplicity of greater than one is intended to support hydro units that have
      multiple turbines on one generator.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:SynchronousMachineDynamics.TurbineGovernorDynamics
    multivalued: true
    alias: turbine_governor_dynamics
    owner: SynchronousMachineUserDefined
    domain_of:
    - SynchronousMachineDynamics
    - AsynchronousMachineDynamics
    - TurbineLoadControllerDynamics
    range: TurbineGovernorDynamics
    required: false
  gen_icompensation_for_gen_j:
    name: gen_icompensation_for_gen_j
    description: Compensation of voltage compensator's generator for current flow
      out of this  generator.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:SynchronousMachineDynamics.GenICompensationForGenJ
    multivalued: true
    alias: gen_icompensation_for_gen_j
    owner: SynchronousMachineUserDefined
    domain_of:
    - SynchronousMachineDynamics
    - VCompIEEEType2
    range: GenICompensationForGenJ
    required: false
  excitation_system_dynamics:
    name: excitation_system_dynamics
    description: Excitation system model associated with this synchronous machine
      model.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:SynchronousMachineDynamics.ExcitationSystemDynamics
    multivalued: false
    alias: excitation_system_dynamics
    owner: SynchronousMachineUserDefined
    domain_of:
    - SynchronousMachineDynamics
    - VoltageCompensatorDynamics
    - PowerSystemStabilizerDynamics
    - UnderexcitationLimiterDynamics
    - DiscontinuousExcitationControlDynamics
    - PFVArControllerType1Dynamics
    - OverexcitationLimiterDynamics
    - PFVArControllerType2Dynamics
    range: ExcitationSystemDynamics
    required: false
  cross_compound_turbine_governor_dynamics:
    name: cross_compound_turbine_governor_dynamics
    description: The cross-compound turbine governor with which this low-pressure
      synchronous machine is associated.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:SynchronousMachineDynamics.CrossCompoundTurbineGovernorDynamics
    multivalued: false
    alias: cross_compound_turbine_governor_dynamics
    owner: SynchronousMachineUserDefined
    domain_of:
    - SynchronousMachineDynamics
    range: CrossCompoundTurbineGovernorDynamics
    required: false
  cross_compound_turbine_governor_dyanmics:
    name: cross_compound_turbine_governor_dyanmics
    description: The cross-compound turbine governor with which this high-pressure
      synchronous machine is associated.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:SynchronousMachineDynamics.CrossCompoundTurbineGovernorDyanmics
    multivalued: false
    alias: cross_compound_turbine_governor_dyanmics
    owner: SynchronousMachineUserDefined
    domain_of:
    - SynchronousMachineDynamics
    range: CrossCompoundTurbineGovernorDynamics
    required: false
  mechanical_load_dynamics:
    name: mechanical_load_dynamics
    description: Mechanical load model associated with this synchronous machine model.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:SynchronousMachineDynamics.MechanicalLoadDynamics
    multivalued: false
    alias: mechanical_load_dynamics
    owner: SynchronousMachineUserDefined
    domain_of:
    - SynchronousMachineDynamics
    - AsynchronousMachineDynamics
    range: MechanicalLoadDynamics
    required: false
  damping:
    name: damping
    description: Damping torque coefficient (<i>D</i>) (&gt;= 0).  A proportionality
      constant that, when multiplied by the angular velocity of the rotor poles with
      respect to the magnetic field (frequency), results in the damping torque.  This
      value is often zero when the sources of damping torques (generator damper windings,
      load damping effects, etc.) are modelled in detail.  Typical value = 0.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RotatingMachineDynamics.damping
    multivalued: false
    alias: damping
    owner: SynchronousMachineUserDefined
    domain_of:
    - RotatingMachineDynamics
    range: float
    required: false
  inertia:
    name: inertia
    description: Inertia constant of generator or motor and mechanical load (<i>H</i>)
      (&gt; 0).  This is the specification for the stored energy in the rotating mass
      when operating at rated speed.  For a generator, this includes the generator
      plus all other elements (turbine, exciter) on the same shaft and has units of
      MW x s.  For a motor, it includes the motor plus its mechanical load. Conventional
      units are PU on the generator MVA base, usually expressed as MW x s / MVA or
      just s. This value is used in the accelerating power reference frame for operator
      training simulator solutions.  Typical value = 3.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RotatingMachineDynamics.inertia
    multivalued: false
    alias: inertia
    owner: SynchronousMachineUserDefined
    domain_of:
    - RotatingMachineDynamics
    range: Seconds
    required: false
  saturation_factor:
    name: saturation_factor
    description: Saturation factor at 120% of rated terminal voltage (<i>S12</i>)
      (&gt;= RotatingMachineDynamics.saturationFactor). Not used by the simplified
      model, defined by <i>S</i>(<i>E2</i>) in the SynchronousMachineSaturationParameters
      diagram.  Typical value = 0,12.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RotatingMachineDynamics.saturationFactor120
    multivalued: false
    alias: saturation_factor
    owner: SynchronousMachineUserDefined
    domain_of:
    - RotatingMachineDynamics
    range: float
    required: false
  stator_leakage_reactance:
    name: stator_leakage_reactance
    description: Stator leakage reactance (<i>Xl</i>) (&gt;= 0). Typical value = 0,15.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RotatingMachineDynamics.statorLeakageReactance
    multivalued: false
    alias: stator_leakage_reactance
    owner: SynchronousMachineUserDefined
    domain_of:
    - RotatingMachineDynamics
    range: PU
    required: false
  stator_resistance:
    name: stator_resistance
    description: Stator (armature) resistance (<i>Rs</i>) (&gt;= 0). Typical value
      = 0,005.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RotatingMachineDynamics.statorResistance
    multivalued: false
    alias: stator_resistance
    owner: SynchronousMachineUserDefined
    domain_of:
    - RotatingMachineDynamics
    range: PU
    required: false
  enabled:
    name: enabled
    description: "Function block used indicator.\r\ntrue = use of function block is\
      \ enabled\r\nfalse = use of function block is disabled."
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:DynamicsFunctionBlock.enabled
    multivalued: false
    alias: enabled
    owner: SynchronousMachineUserDefined
    domain_of:
    - ProtectiveAction
    - EndDeviceFunction
    - RegulatingControl
    - DynamicsFunctionBlock
    range: boolean
    required: false
  alias_name:
    name: alias_name
    description: "The aliasName is free text human readable name of the object alternative\
      \ to IdentifiedObject.name. It may be non unique and may not correlate to a\
      \ naming hierarchy.\r\nThe attribute aliasName is retained because of backwards\
      \ compatibility between CIM relases. It is however recommended to replace aliasName\
      \ with the Name class as aliasName is planned for retirement at a future time.\r\
      \n\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.aliasName
    multivalued: false
    alias: alias_name
    owner: SynchronousMachineUserDefined
    domain_of:
    - IdentifiedObject
    range: string
    required: false
  description:
    name: description
    description: The description is a free human readable text describing or naming
      the object. It may be non unique and may not correlate to a naming hierarchy.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.description
    multivalued: false
    alias: description
    owner: SynchronousMachineUserDefined
    domain_of:
    - IdentifiedObject
    - NameType
    - NameTypeAuthority
    - DataSet
    - SwitchingStepGroup
    - AreaReserveSpec
    range: string
    required: false
  m_rid:
    name: m_rid
    description: "Master resource identifier issued by a model authority. The mRID\
      \ is unique within an exchange context. Global uniqueness is easily achieved\
      \ by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is\
      \ strongly recommended.\r\nFor CIMXML data files in RDF syntax conforming to\
      \ IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify\
      \ CIM object elements."
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.mRID
    multivalued: false
    alias: m_rid
    owner: SynchronousMachineUserDefined
    domain_of:
    - IdentifiedObject
    - DataSet
    range: string
    required: false
  diagram_objects:
    name: diagram_objects
    description: The diagram objects that are associated with the domain object.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.DiagramObjects
    multivalued: true
    alias: diagram_objects
    owner: SynchronousMachineUserDefined
    domain_of:
    - IdentifiedObject
    range: DiagramObject
    required: false
  instance_set:
    name: instance_set
    description: Dataset containing the data objects.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.InstanceSet
    multivalued: false
    alias: instance_set
    owner: SynchronousMachineUserDefined
    domain_of:
    - IdentifiedObject
    range: InstanceSet
    required: true
  names:
    name: names
    description: All names of this identified object.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.Names
    multivalued: true
    alias: names
    owner: SynchronousMachineUserDefined
    domain_of:
    - IdentifiedObject
    - NameType
    range: Name
    required: false
  properties_cimdata_object:
    name: properties_cimdata_object
    description: The single CIM data object in the appropriate dataset context.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.PropertiesCIMDataObject
    multivalued: false
    alias: properties_cimdata_object
    owner: SynchronousMachineUserDefined
    domain_of:
    - IdentifiedObject
    range: ChangeSetMember
    required: false
  targeting_cimdata_object:
    name: targeting_cimdata_object
    description: Data objects registered.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.TargetingCIMDataObject
    multivalued: true
    alias: targeting_cimdata_object
    owner: SynchronousMachineUserDefined
    domain_of:
    - IdentifiedObject
    range: ChangeSetMember
    required: false
class_uri: cim:SynchronousMachineUserDefined