Class: StaticVarCompensator
_A facility for providing variable and controllable shunt reactive power. The SVC typically consists of a stepdown transformer, filter, thyristor-controlled reactor, and thyristor-switched capacitor arms. _
_ _
The SVC may operate in fixed MVar output mode or in voltage control mode. When in voltage control mode, the output of the SVC will be proportional to the deviation of voltage at the controlled bus from the voltage setpoint. The SVC characteristic slope defines the proportion. If the voltage at the controlled bus is equal to the voltage setpoint, the SVC MVar output is zero.
classDiagram
class StaticVarCompensator
RegulatingCondEq <|-- StaticVarCompensator
StaticVarCompensator : additional_equipment_container
StaticVarCompensator --> EquipmentContainer : additional_equipment_container
StaticVarCompensator : aggregate
StaticVarCompensator : alias_name
StaticVarCompensator : asset_datasheet
StaticVarCompensator --> AssetInfo : asset_datasheet
StaticVarCompensator : assets
StaticVarCompensator --> Asset : assets
StaticVarCompensator : base_voltage
StaticVarCompensator --> BaseVoltage : base_voltage
StaticVarCompensator : capacitive_rating
StaticVarCompensator --> Reactance : capacitive_rating
StaticVarCompensator : clearances
StaticVarCompensator --> ClearanceDocument : clearances
StaticVarCompensator : configuration_event
StaticVarCompensator --> ConfigurationEvent : configuration_event
StaticVarCompensator : contingency_equipment
StaticVarCompensator --> ContingencyEquipment : contingency_equipment
StaticVarCompensator : control_enabled
StaticVarCompensator : controls
StaticVarCompensator --> Control : controls
StaticVarCompensator : description
StaticVarCompensator : diagram_objects
StaticVarCompensator --> DiagramObject : diagram_objects
StaticVarCompensator : energy_component
StaticVarCompensator --> EnergyComponent : energy_component
StaticVarCompensator : eqiupment_limit_series_component
StaticVarCompensator --> EquipmentLimitSeriesComponent : eqiupment_limit_series_component
StaticVarCompensator : equipment_container
StaticVarCompensator --> EquipmentContainer : equipment_container
StaticVarCompensator : equipment_unavailability_schedule
StaticVarCompensator --> EquipmentUnavailabilitySchedule : equipment_unavailability_schedule
StaticVarCompensator : faults
StaticVarCompensator --> Fault : faults
StaticVarCompensator : generic_action
StaticVarCompensator --> GenericAction : generic_action
StaticVarCompensator : grounding_action
StaticVarCompensator --> GroundAction : grounding_action
StaticVarCompensator : in_service
StaticVarCompensator : inductive_rating
StaticVarCompensator --> Reactance : inductive_rating
StaticVarCompensator : instance_set
StaticVarCompensator --> InstanceSet : instance_set
StaticVarCompensator : jumping_action
StaticVarCompensator --> JumperAction : jumping_action
StaticVarCompensator : limit_dependency_model
StaticVarCompensator --> LimitDependency : limit_dependency_model
StaticVarCompensator : location
StaticVarCompensator --> Location : location
StaticVarCompensator : m_rid
StaticVarCompensator : measurements
StaticVarCompensator --> Measurement : measurements
StaticVarCompensator : names
StaticVarCompensator --> Name : names
StaticVarCompensator : network_analysis_enabled
StaticVarCompensator : normally_in_service
StaticVarCompensator : operating_share
StaticVarCompensator --> OperatingShare : operating_share
StaticVarCompensator : operational_limit_set
StaticVarCompensator --> OperationalLimitSet : operational_limit_set
StaticVarCompensator : operational_restrictions
StaticVarCompensator --> OperationalRestriction : operational_restrictions
StaticVarCompensator : operational_tags
StaticVarCompensator --> OperationalTag : operational_tags
StaticVarCompensator : outage
StaticVarCompensator --> Outage : outage
StaticVarCompensator : outages
StaticVarCompensator --> Outage : outages
StaticVarCompensator : pin_equipment
StaticVarCompensator --> PinEquipment : pin_equipment
StaticVarCompensator : properties_cimdata_object
StaticVarCompensator --> ChangeSetMember : properties_cimdata_object
StaticVarCompensator : protection_equipments
StaticVarCompensator --> ProtectionEquipment : protection_equipments
StaticVarCompensator : protective_action_adjustment
StaticVarCompensator --> ProtectiveActionAdjustment : protective_action_adjustment
StaticVarCompensator : protective_action_equipment
StaticVarCompensator --> ProtectiveActionEquipment : protective_action_equipment
StaticVarCompensator : psrevents
StaticVarCompensator --> PSREvent : psrevents
StaticVarCompensator : psrtype
StaticVarCompensator --> PSRType : psrtype
StaticVarCompensator : q
StaticVarCompensator --> ReactivePower : q
StaticVarCompensator : regulating_control
StaticVarCompensator --> RegulatingControl : regulating_control
StaticVarCompensator : reporting_group
StaticVarCompensator --> ReportingGroup : reporting_group
StaticVarCompensator : s_vccontrol_mode
StaticVarCompensator --> SVCControlMode : s_vccontrol_mode
StaticVarCompensator : slope
StaticVarCompensator --> VoltagePerReactivePower : slope
StaticVarCompensator : static_var_compensator_dynamics
StaticVarCompensator --> StaticVarCompensatorDynamics : static_var_compensator_dynamics
StaticVarCompensator : sv_status
StaticVarCompensator --> SvStatus : sv_status
StaticVarCompensator : targeting_cimdata_object
StaticVarCompensator --> ChangeSetMember : targeting_cimdata_object
StaticVarCompensator : terminals
StaticVarCompensator --> Terminal : terminals
StaticVarCompensator : usage_points
StaticVarCompensator --> UsagePoint : usage_points
StaticVarCompensator : verification_action
StaticVarCompensator --> VerificationAction : verification_action
StaticVarCompensator : voltage_set_point
StaticVarCompensator --> Voltage : voltage_set_point
StaticVarCompensator : weather_station
StaticVarCompensator --> WeatherStation : weather_station
Inheritance
- IdentifiedObject
- PowerSystemResource
- Equipment
- ConductingEquipment
- EnergyConnection
- RegulatingCondEq
- StaticVarCompensator
- RegulatingCondEq
- EnergyConnection
- ConductingEquipment
- Equipment
- PowerSystemResource
Slots
| Name | Cardinality and Range | Description | Inheritance |
|---|---|---|---|
| capacitive_rating | 0..1 Reactance |
Capacitive reactance at maximum capacitive reactive power | direct |
| inductive_rating | 0..1 Reactance |
Inductive reactance at maximum inductive reactive power | direct |
| q | 0..1 ReactivePower |
Reactive power injection | direct |
| slope | 0..1 VoltagePerReactivePower |
The characteristics slope of an SVC defines how the reactive power output cha... | direct |
| s_vccontrol_mode | 0..1 SVCControlMode |
SVC control mode | direct |
| voltage_set_point | 0..1 Voltage |
The reactive power output of the SVC is proportional to the difference betwee... | direct |
| static_var_compensator_dynamics | 0..1 StaticVarCompensatorDynamics |
Static Var Compensator dynamics model used to describe dynamic behaviour of t... | direct |
| control_enabled | 0..1 Boolean |
Specifies the regulation status of the equipment | RegulatingCondEq |
| regulating_control | 0..1 RegulatingControl |
The regulating control scheme in which this equipment participates | RegulatingCondEq |
| energy_component | 0..* EnergyComponent |
EnergyConnection | |
| protective_action_adjustment | 0..* ProtectiveActionAdjustment |
The operating condition to the Conducting Equipment is changed when protectiv... | ConductingEquipment |
| sv_status | 0..* SvStatus |
The status state variable associated with this conducting equipment | ConductingEquipment |
| protection_equipments | 0..* ProtectionEquipment |
Protection equipment used to protect specific conducting equipment | ConductingEquipment |
| base_voltage | 0..1 BaseVoltage |
Base voltage of this conducting equipment | ConductingEquipment |
| terminals | 0..* Terminal |
Conducting equipment have terminals that may be connected to other conducting... | ConductingEquipment |
| jumping_action | 0..1 JumperAction |
Jumper action involving jumping operation on this conducting equipment | ConductingEquipment |
| grounding_action | 0..1 GroundAction |
Action involving grounding operation on this conducting equipment | ConductingEquipment |
| outage | 0..1 Outage |
The outage that is isolated by the outage isolation equipment | ConductingEquipment |
| aggregate | 0..1 Boolean |
The aggregate flag provides an alternative way of representing an aggregated ... | Equipment |
| in_service | 0..1 Boolean |
Specifies the availability of the equipment | Equipment |
| network_analysis_enabled | 0..1 Boolean |
The equipment is enabled to participate in network analysis | Equipment |
| normally_in_service | 0..1 Boolean |
Specifies the availability of the equipment under normal operating conditions | Equipment |
| weather_station | 0..* WeatherStation |
Equipment | |
| operational_limit_set | 0..* OperationalLimitSet |
The operational limit sets associated with this equipment | Equipment |
| contingency_equipment | 0..* ContingencyEquipment |
The contingency equipments in which this equipment participates | Equipment |
| equipment_container | 0..1 EquipmentContainer |
Container of this equipment | Equipment |
| faults | 0..* Fault |
All faults on this equipment | Equipment |
| limit_dependency_model | 0..* LimitDependency |
Limit dependencymodels organized under this equipment as a means for organizi... | Equipment |
| eqiupment_limit_series_component | 0..* EquipmentLimitSeriesComponent |
Equipment limit series calculation component to which this equipment contribu... | Equipment |
| protective_action_equipment | 0..* ProtectiveActionEquipment |
Protective action is controlling equipment | Equipment |
| pin_equipment | 0..* PinEquipment |
Equipment | |
| equipment_unavailability_schedule | 0..* EquipmentUnavailabilitySchedule |
Equipment | |
| additional_equipment_container | 0..* EquipmentContainer |
Additional equipment container beyond the primary equipment container | Equipment |
| usage_points | 0..* UsagePoint |
All usage points connected to the electrical grid through this equipment | Equipment |
| outages | 0..* Outage |
All outages in which this equipment is involved | Equipment |
| operational_restrictions | 0..* OperationalRestriction |
All operational restrictions for this equipment | Equipment |
| controls | 0..* Control |
The controller outputs used to actually govern a regulating device, e | PowerSystemResource |
| measurements | 0..* Measurement |
The measurements associated with this power system resource | PowerSystemResource |
| psrtype | 0..1 PSRType |
Custom classification for this power system resource | PowerSystemResource |
| configuration_event | 0..* ConfigurationEvent |
All configuration events created for this Power System resource | PowerSystemResource |
| reporting_group | 0..* ReportingGroup |
Reporting groups to which this power system resource belongs | PowerSystemResource |
| operating_share | 0..* OperatingShare |
The operating shares of this power system resource | PowerSystemResource |
| asset_datasheet | 0..1 AssetInfo |
Datasheet information for this power system resource | PowerSystemResource |
| verification_action | 0..* VerificationAction |
The verification action that is performed on the power system resource | PowerSystemResource |
| clearances | 0..* ClearanceDocument |
All clearances applicable to this power system resource | PowerSystemResource |
| generic_action | 0..* GenericAction |
The generic action that is performed on the power system resource | PowerSystemResource |
| psrevents | 0..* PSREvent |
All events associated with this power system resource | PowerSystemResource |
| assets | 0..* Asset |
All assets represented by this power system resource | PowerSystemResource |
| location | 0..1 Location |
Location of this power system resource | PowerSystemResource |
| operational_tags | 0..* OperationalTag |
All operational tags placed on this power system resource | PowerSystemResource |
| alias_name | 0..1 String |
The aliasName is free text human readable name of the object alternative to I... | IdentifiedObject |
| description | 0..1 String |
The description is a free human readable text describing or naming the object | IdentifiedObject |
| m_rid | 0..1 String |
Master resource identifier issued by a model authority | IdentifiedObject |
| diagram_objects | 0..* DiagramObject |
The diagram objects that are associated with the domain object | IdentifiedObject |
| instance_set | 1..1 InstanceSet |
Dataset containing the data objects | IdentifiedObject |
| names | 0..* Name |
All names of this identified object | IdentifiedObject |
| properties_cimdata_object | 0..1 ChangeSetMember |
The single CIM data object in the appropriate dataset context | IdentifiedObject |
| targeting_cimdata_object | 0..* ChangeSetMember |
Data objects registered | IdentifiedObject |
Usages
| used by | used in | type | used |
|---|---|---|---|
| StaticVarCompensatorDynamics | static_var_compensator | range | StaticVarCompensator |
| SVCUserDefined | static_var_compensator | range | StaticVarCompensator |
Identifier and Mapping Information
Schema Source
- from schema: https://cim.ucaiug.io/ns#TC57CIM
Mappings
| Mapping Type | Mapped Value |
|---|---|
| self | cim:StaticVarCompensator |
| native | cim:StaticVarCompensator |
LinkML Source
Direct
name: StaticVarCompensator
description: "A facility for providing variable and controllable shunt reactive power.\
\ The SVC typically consists of a stepdown transformer, filter, thyristor-controlled\
\ reactor, and thyristor-switched capacitor arms.\r\n\r\nThe SVC may operate in\
\ fixed MVar output mode or in voltage control mode. When in voltage control mode,\
\ the output of the SVC will be proportional to the deviation of voltage at the\
\ controlled bus from the voltage setpoint. The SVC characteristic slope defines\
\ the proportion. If the voltage at the controlled bus is equal to the voltage\
\ setpoint, the SVC MVar output is zero."
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
is_a: RegulatingCondEq
attributes:
capacitive_rating:
name: capacitive_rating
description: Capacitive reactance at maximum capacitive reactive power. Shall
always be positive.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:StaticVarCompensator.capacitiveRating
multivalued: false
domain_of:
- StaticVarCompensator
- SVC
range: Reactance
required: false
inductive_rating:
name: inductive_rating
description: 'Inductive reactance at maximum inductive reactive power. Shall
always be negative. '
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:StaticVarCompensator.inductiveRating
multivalued: false
domain_of:
- StaticVarCompensator
- SVC
range: Reactance
required: false
q:
name: q
description: "Reactive power injection. Load sign convention is used, i.e. positive\
\ sign means flow out from a node.\r\nStarting value for a steady state solution."
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:StaticVarCompensator.q
multivalued: false
domain_of:
- SvPowerFlow
- RotatingMachine
- EquivalentInjection
- PowerElectronicsConnection
- PowerElectronicsConnectionPhase
- ACDCConverter
- EnergyConsumerPhase
- EnergyConsumer
- StaticVarCompensator
- ExternalNetworkInjection
- UnderexcLimIEEE2
- UnderexcLim2Simplified
range: ReactivePower
required: false
slope:
name: slope
description: "The characteristics slope of an SVC defines how the reactive power\
\ output changes in proportion to the difference between the regulated bus voltage\
\ and the voltage setpoint.\r\nThe attribute shall be a positive value or zero."
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:StaticVarCompensator.slope
multivalued: false
domain_of:
- StaticVarCompensator
range: VoltagePerReactivePower
required: false
s_vccontrol_mode:
name: s_vccontrol_mode
description: SVC control mode.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:StaticVarCompensator.sVCControlMode
multivalued: false
domain_of:
- StaticVarCompensator
range: SVCControlMode
required: false
voltage_set_point:
name: voltage_set_point
description: The reactive power output of the SVC is proportional to the difference
between the voltage at the regulated bus and the voltage setpoint. When the
regulated bus voltage is equal to the voltage setpoint, the reactive power output
is zero.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:StaticVarCompensator.voltageSetPoint
multivalued: false
domain_of:
- StaticVarCompensator
range: Voltage
required: false
static_var_compensator_dynamics:
name: static_var_compensator_dynamics
description: Static Var Compensator dynamics model used to describe dynamic behaviour
of this Static Var Compensator.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:StaticVarCompensator.StaticVarCompensatorDynamics
multivalued: false
domain_of:
- StaticVarCompensator
range: StaticVarCompensatorDynamics
required: false
class_uri: cim:StaticVarCompensator
Induced
name: StaticVarCompensator
description: "A facility for providing variable and controllable shunt reactive power.\
\ The SVC typically consists of a stepdown transformer, filter, thyristor-controlled\
\ reactor, and thyristor-switched capacitor arms.\r\n\r\nThe SVC may operate in\
\ fixed MVar output mode or in voltage control mode. When in voltage control mode,\
\ the output of the SVC will be proportional to the deviation of voltage at the\
\ controlled bus from the voltage setpoint. The SVC characteristic slope defines\
\ the proportion. If the voltage at the controlled bus is equal to the voltage\
\ setpoint, the SVC MVar output is zero."
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
is_a: RegulatingCondEq
attributes:
capacitive_rating:
name: capacitive_rating
description: Capacitive reactance at maximum capacitive reactive power. Shall
always be positive.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:StaticVarCompensator.capacitiveRating
multivalued: false
alias: capacitive_rating
owner: StaticVarCompensator
domain_of:
- StaticVarCompensator
- SVC
range: Reactance
required: false
inductive_rating:
name: inductive_rating
description: 'Inductive reactance at maximum inductive reactive power. Shall
always be negative. '
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:StaticVarCompensator.inductiveRating
multivalued: false
alias: inductive_rating
owner: StaticVarCompensator
domain_of:
- StaticVarCompensator
- SVC
range: Reactance
required: false
q:
name: q
description: "Reactive power injection. Load sign convention is used, i.e. positive\
\ sign means flow out from a node.\r\nStarting value for a steady state solution."
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:StaticVarCompensator.q
multivalued: false
alias: q
owner: StaticVarCompensator
domain_of:
- SvPowerFlow
- RotatingMachine
- EquivalentInjection
- PowerElectronicsConnection
- PowerElectronicsConnectionPhase
- ACDCConverter
- EnergyConsumerPhase
- EnergyConsumer
- StaticVarCompensator
- ExternalNetworkInjection
- UnderexcLimIEEE2
- UnderexcLim2Simplified
range: ReactivePower
required: false
slope:
name: slope
description: "The characteristics slope of an SVC defines how the reactive power\
\ output changes in proportion to the difference between the regulated bus voltage\
\ and the voltage setpoint.\r\nThe attribute shall be a positive value or zero."
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:StaticVarCompensator.slope
multivalued: false
alias: slope
owner: StaticVarCompensator
domain_of:
- StaticVarCompensator
range: VoltagePerReactivePower
required: false
s_vccontrol_mode:
name: s_vccontrol_mode
description: SVC control mode.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:StaticVarCompensator.sVCControlMode
multivalued: false
alias: s_vccontrol_mode
owner: StaticVarCompensator
domain_of:
- StaticVarCompensator
range: SVCControlMode
required: false
voltage_set_point:
name: voltage_set_point
description: The reactive power output of the SVC is proportional to the difference
between the voltage at the regulated bus and the voltage setpoint. When the
regulated bus voltage is equal to the voltage setpoint, the reactive power output
is zero.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:StaticVarCompensator.voltageSetPoint
multivalued: false
alias: voltage_set_point
owner: StaticVarCompensator
domain_of:
- StaticVarCompensator
range: Voltage
required: false
static_var_compensator_dynamics:
name: static_var_compensator_dynamics
description: Static Var Compensator dynamics model used to describe dynamic behaviour
of this Static Var Compensator.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:StaticVarCompensator.StaticVarCompensatorDynamics
multivalued: false
alias: static_var_compensator_dynamics
owner: StaticVarCompensator
domain_of:
- StaticVarCompensator
range: StaticVarCompensatorDynamics
required: false
control_enabled:
name: control_enabled
description: Specifies the regulation status of the equipment. True is regulating,
false is not regulating.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:RegulatingCondEq.controlEnabled
multivalued: false
alias: control_enabled
owner: StaticVarCompensator
domain_of:
- RegulatingCondEq
- TapChanger
range: boolean
required: false
regulating_control:
name: regulating_control
description: The regulating control scheme in which this equipment participates.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:RegulatingCondEq.RegulatingControl
multivalued: false
alias: regulating_control
owner: StaticVarCompensator
domain_of:
- Terminal
- RegulatingCondEq
- RegulationSchedule
- ProtectiveActionRegulation
range: RegulatingControl
required: false
energy_component:
name: energy_component
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:EnergyConnection.EnergyComponent
multivalued: true
alias: energy_component
owner: StaticVarCompensator
domain_of:
- EnergyGroup
- EnergyConnection
range: EnergyComponent
required: false
protective_action_adjustment:
name: protective_action_adjustment
description: 'The operating condition to the Conducting Equipment is changed when
protective action adjustment is activated. For ShuntCompensator or other conducting
equipment that operates on discrete values (integer), the values given in float
will be rounded. '
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:ConductingEquipment.ProtectiveActionAdjustment
multivalued: true
alias: protective_action_adjustment
owner: StaticVarCompensator
domain_of:
- Measurement
- ConductingEquipment
- DCConductingEquipment
range: ProtectiveActionAdjustment
required: false
sv_status:
name: sv_status
description: The status state variable associated with this conducting equipment.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ConductingEquipment.SvStatus
multivalued: true
alias: sv_status
owner: StaticVarCompensator
domain_of:
- ConductingEquipment
range: SvStatus
required: false
protection_equipments:
name: protection_equipments
description: 'Protection equipment used to protect specific conducting equipment. '
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ConductingEquipment.ProtectionEquipments
multivalued: true
alias: protection_equipments
owner: StaticVarCompensator
domain_of:
- ConductingEquipment
range: ProtectionEquipment
required: false
base_voltage:
name: base_voltage
description: Base voltage of this conducting equipment. Use only when there is
no voltage level container used and only one base voltage applies. For example,
not used for transformers.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:ConductingEquipment.BaseVoltage
multivalued: false
alias: base_voltage
owner: StaticVarCompensator
domain_of:
- TopologicalNode
- TransformerEnd
- ConductingEquipment
- VoltageLevel
- AssetDeployment
range: BaseVoltage
required: false
terminals:
name: terminals
description: Conducting equipment have terminals that may be connected to other
conducting equipment terminals via connectivity nodes or topological nodes.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:ConductingEquipment.Terminals
multivalued: true
alias: terminals
owner: StaticVarCompensator
domain_of:
- ConnectivityNode
- ConductingEquipment
range: Terminal
required: false
jumping_action:
name: jumping_action
description: Jumper action involving jumping operation on this conducting equipment.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ConductingEquipment.JumpingAction
multivalued: false
alias: jumping_action
owner: StaticVarCompensator
domain_of:
- ConductingEquipment
range: JumperAction
required: false
grounding_action:
name: grounding_action
description: Action involving grounding operation on this conducting equipment.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ConductingEquipment.GroundingAction
multivalued: false
alias: grounding_action
owner: StaticVarCompensator
domain_of:
- ConductingEquipment
range: GroundAction
required: false
outage:
name: outage
description: The outage that is isolated by the outage isolation equipment.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:ConductingEquipment.Outage
multivalued: false
alias: outage
owner: StaticVarCompensator
domain_of:
- Incident
- SwitchingPlan
- UsagePoint
- ConductingEquipment
- Crew
- EstimatedRestorationTime
- OutageArea
- Fault
range: Outage
required: false
aggregate:
name: aggregate
description: "The aggregate flag provides an alternative way of representing an\
\ aggregated (equivalent) element. It is applicable in cases when the dedicated\
\ classes for equivalent equipment do not have all of the attributes necessary\
\ to represent the required level of detail. In case the flag is set to “true”\
\ the single instance of equipment represents multiple pieces of equipment that\
\ have been modelled together as an aggregate equivalent obtained by a network\
\ reduction procedure. Examples would be power transformers or synchronous machines\
\ operating in parallel modelled as a single aggregate power transformer or\
\ aggregate synchronous machine. \r\nThe attribute is not used for EquivalentBranch,\
\ EquivalentShunt and EquivalentInjection."
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.aggregate
multivalued: false
alias: aggregate
owner: StaticVarCompensator
domain_of:
- Equipment
- ReadingType
range: boolean
required: false
in_service:
name: in_service
description: Specifies the availability of the equipment. True means the equipment
is available for topology processing, which determines if the equipment is energized
or not. False means that the equipment is treated by network applications as
if it is not in the model.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.inService
multivalued: false
alias: in_service
owner: StaticVarCompensator
domain_of:
- Equipment
- SvStatus
- ProtectiveActionEquipment
range: boolean
required: false
network_analysis_enabled:
name: network_analysis_enabled
description: The equipment is enabled to participate in network analysis. If
unspecified, the value is assumed to be true.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.networkAnalysisEnabled
multivalued: false
alias: network_analysis_enabled
owner: StaticVarCompensator
domain_of:
- Equipment
range: boolean
required: false
normally_in_service:
name: normally_in_service
description: Specifies the availability of the equipment under normal operating
conditions. True means the equipment is available for topology processing, which
determines if the equipment is energized or not. False means that the equipment
is treated by network applications as if it is not in the model.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.normallyInService
multivalued: false
alias: normally_in_service
owner: StaticVarCompensator
domain_of:
- Equipment
range: boolean
required: false
weather_station:
name: weather_station
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.WeatherStation
multivalued: true
alias: weather_station
owner: StaticVarCompensator
domain_of:
- Equipment
range: WeatherStation
required: false
operational_limit_set:
name: operational_limit_set
description: The operational limit sets associated with this equipment.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:Equipment.OperationalLimitSet
multivalued: true
alias: operational_limit_set
owner: StaticVarCompensator
domain_of:
- ACDCTerminal
- OperationalLimit
- Equipment
range: OperationalLimitSet
required: false
contingency_equipment:
name: contingency_equipment
description: The contingency equipments in which this equipment participates.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.ContingencyEquipment
multivalued: true
alias: contingency_equipment
owner: StaticVarCompensator
domain_of:
- Equipment
range: ContingencyEquipment
required: false
equipment_container:
name: equipment_container
description: Container of this equipment.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.EquipmentContainer
multivalued: false
alias: equipment_container
owner: StaticVarCompensator
domain_of:
- Equipment
range: EquipmentContainer
required: false
faults:
name: faults
description: All faults on this equipment.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.Faults
multivalued: true
alias: faults
owner: StaticVarCompensator
domain_of:
- Equipment
- Outage
- FaultCauseType
range: Fault
required: false
limit_dependency_model:
name: limit_dependency_model
description: Limit dependencymodels organized under this equipment as a means
for organizing the model in a tree view.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:Equipment.LimitDependencyModel
multivalued: true
alias: limit_dependency_model
owner: StaticVarCompensator
domain_of:
- OperationalLimit
- Equipment
range: LimitDependency
required: false
eqiupment_limit_series_component:
name: eqiupment_limit_series_component
description: Equipment limit series calculation component to which this equipment
contributes.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.EqiupmentLimitSeriesComponent
multivalued: true
alias: eqiupment_limit_series_component
owner: StaticVarCompensator
domain_of:
- Equipment
range: EquipmentLimitSeriesComponent
required: false
protective_action_equipment:
name: protective_action_equipment
description: Protective action is controlling equipment. This can be direct signals
from the control center, or emulation of action done by protection equipment.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.ProtectiveActionEquipment
multivalued: true
alias: protective_action_equipment
owner: StaticVarCompensator
domain_of:
- Equipment
range: ProtectiveActionEquipment
required: false
pin_equipment:
name: pin_equipment
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.PinEquipment
multivalued: true
alias: pin_equipment
owner: StaticVarCompensator
domain_of:
- Equipment
range: PinEquipment
required: false
equipment_unavailability_schedule:
name: equipment_unavailability_schedule
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.EquipmentUnavailabilitySchedule
multivalued: true
alias: equipment_unavailability_schedule
owner: StaticVarCompensator
domain_of:
- Equipment
- UnavailabilitySwitchAction
- UnavailablitySchedule
range: EquipmentUnavailabilitySchedule
required: false
additional_equipment_container:
name: additional_equipment_container
description: Additional equipment container beyond the primary equipment container. The
equipment is contained in another equipment container, but also grouped with
this equipment container.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.AdditionalEquipmentContainer
multivalued: true
alias: additional_equipment_container
owner: StaticVarCompensator
domain_of:
- Equipment
range: EquipmentContainer
required: false
usage_points:
name: usage_points
description: All usage points connected to the electrical grid through this equipment.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.UsagePoints
multivalued: true
alias: usage_points
owner: StaticVarCompensator
domain_of:
- Equipment
- CustomerAgreement
- ServiceCategory
- PricingStructure
- EndDeviceControl
- UsagePointGroup
- ServiceLocation
- MetrologyRequirement
- ServiceSupplier
- UsagePointLocation
range: UsagePoint
required: false
outages:
name: outages
description: All outages in which this equipment is involved.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.Outages
multivalued: true
alias: outages
owner: StaticVarCompensator
domain_of:
- Equipment
range: Outage
required: false
operational_restrictions:
name: operational_restrictions
description: All operational restrictions for this equipment.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.OperationalRestrictions
multivalued: true
alias: operational_restrictions
owner: StaticVarCompensator
domain_of:
- Equipment
- ProductAssetModel
range: OperationalRestriction
required: false
controls:
name: controls
description: The controller outputs used to actually govern a regulating device,
e.g. the magnetization of a synchronous machine or capacitor bank breaker actuator.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.Controls
multivalued: true
alias: controls
owner: StaticVarCompensator
domain_of:
- PowerSystemResource
- HostControlArea
range: Control
required: false
measurements:
name: measurements
description: The measurements associated with this power system resource.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.Measurements
multivalued: true
alias: measurements
owner: StaticVarCompensator
domain_of:
- PowerSystemResource
- ACDCTerminal
- Asset
- Location
- Procedure
- AnalogLimitSet
- AccumulatorLimitSet
range: Measurement
required: false
psrtype:
name: psrtype
description: Custom classification for this power system resource.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.PSRType
multivalued: false
alias: psrtype
owner: StaticVarCompensator
domain_of:
- PowerSystemResource
range: PSRType
required: false
configuration_event:
name: configuration_event
description: All configuration events created for this Power System resource.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.ConfigurationEvent
multivalued: true
alias: configuration_event
owner: StaticVarCompensator
domain_of:
- PowerSystemResource
- FaultCauseType
range: ConfigurationEvent
required: false
reporting_group:
name: reporting_group
description: Reporting groups to which this power system resource belongs.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.ReportingGroup
multivalued: true
alias: reporting_group
owner: StaticVarCompensator
domain_of:
- PowerSystemResource
- BusNameMarker
- TopologicalNode
- ReportingSuperGroup
range: ReportingGroup
required: false
operating_share:
name: operating_share
description: The operating shares of this power system resource.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.OperatingShare
multivalued: true
alias: operating_share
owner: StaticVarCompensator
domain_of:
- PowerSystemResource
- OperatingParticipant
range: OperatingShare
required: false
asset_datasheet:
name: asset_datasheet
description: Datasheet information for this power system resource.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.AssetDatasheet
multivalued: false
alias: asset_datasheet
owner: StaticVarCompensator
domain_of:
- PowerSystemResource
range: AssetInfo
required: false
verification_action:
name: verification_action
description: The verification action that is performed on the power system resource
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.VerificationAction
multivalued: true
alias: verification_action
owner: StaticVarCompensator
domain_of:
- PowerSystemResource
range: VerificationAction
required: false
clearances:
name: clearances
description: All clearances applicable to this power system resource.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.Clearances
multivalued: true
alias: clearances
owner: StaticVarCompensator
domain_of:
- PowerSystemResource
range: ClearanceDocument
required: false
generic_action:
name: generic_action
description: The generic action that is performed on the power system resource
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.GenericAction
multivalued: true
alias: generic_action
owner: StaticVarCompensator
domain_of:
- PowerSystemResource
range: GenericAction
required: false
psrevents:
name: psrevents
description: All events associated with this power system resource.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.PSREvents
multivalued: true
alias: psrevents
owner: StaticVarCompensator
domain_of:
- PowerSystemResource
range: PSREvent
required: false
assets:
name: assets
description: All assets represented by this power system resource. For example,
multiple conductor assets are electrically modelled as a single AC line segment.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.Assets
multivalued: true
alias: assets
owner: StaticVarCompensator
domain_of:
- PowerSystemResource
- AssetInfo
- Location
- WorkTask
- ErpRecDelvLineItem
- AssetContainer
- ActivityRecord
- Procedure
- ReliabilityInfo
- AssetPropertyCurve
- AssetOrganisationRole
- ScheduledEvent
range: Asset
required: false
location:
name: location
description: Location of this power system resource.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.Location
multivalued: false
alias: location
owner: StaticVarCompensator
domain_of:
- PowerSystemResource
- Asset
- Incident
- SwitchingOrder
- TroubleOrder
- Crew
- Fault
- PointOfSale
- TroubleTicket
- OutageOrder
- EnvironmentalMonitoringStation
- EnvironmentalLocationType
- PositionPoint
- FailureEvent
range: Location
required: false
operational_tags:
name: operational_tags
description: All operational tags placed on this power system resource.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.OperationalTags
multivalued: true
alias: operational_tags
owner: StaticVarCompensator
domain_of:
- PowerSystemResource
- Asset
range: OperationalTag
required: false
alias_name:
name: alias_name
description: "The aliasName is free text human readable name of the object alternative\
\ to IdentifiedObject.name. It may be non unique and may not correlate to a\
\ naming hierarchy.\r\nThe attribute aliasName is retained because of backwards\
\ compatibility between CIM relases. It is however recommended to replace aliasName\
\ with the Name class as aliasName is planned for retirement at a future time.\r\
\n\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.aliasName
multivalued: false
alias: alias_name
owner: StaticVarCompensator
domain_of:
- IdentifiedObject
range: string
required: false
description:
name: description
description: The description is a free human readable text describing or naming
the object. It may be non unique and may not correlate to a naming hierarchy.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.description
multivalued: false
alias: description
owner: StaticVarCompensator
domain_of:
- IdentifiedObject
- NameType
- NameTypeAuthority
- DataSet
- SwitchingStepGroup
- AreaReserveSpec
range: string
required: false
m_rid:
name: m_rid
description: "Master resource identifier issued by a model authority. The mRID\
\ is unique within an exchange context. Global uniqueness is easily achieved\
\ by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is\
\ strongly recommended.\r\nFor CIMXML data files in RDF syntax conforming to\
\ IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify\
\ CIM object elements."
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.mRID
multivalued: false
alias: m_rid
owner: StaticVarCompensator
domain_of:
- IdentifiedObject
- DataSet
range: string
required: false
diagram_objects:
name: diagram_objects
description: The diagram objects that are associated with the domain object.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.DiagramObjects
multivalued: true
alias: diagram_objects
owner: StaticVarCompensator
domain_of:
- IdentifiedObject
range: DiagramObject
required: false
instance_set:
name: instance_set
description: Dataset containing the data objects.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.InstanceSet
multivalued: false
alias: instance_set
owner: StaticVarCompensator
domain_of:
- IdentifiedObject
range: InstanceSet
required: true
names:
name: names
description: All names of this identified object.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.Names
multivalued: true
alias: names
owner: StaticVarCompensator
domain_of:
- IdentifiedObject
- NameType
range: Name
required: false
properties_cimdata_object:
name: properties_cimdata_object
description: The single CIM data object in the appropriate dataset context.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.PropertiesCIMDataObject
multivalued: false
alias: properties_cimdata_object
owner: StaticVarCompensator
domain_of:
- IdentifiedObject
range: ChangeSetMember
required: false
targeting_cimdata_object:
name: targeting_cimdata_object
description: Data objects registered.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.TargetingCIMDataObject
multivalued: true
alias: targeting_cimdata_object
owner: StaticVarCompensator
domain_of:
- IdentifiedObject
range: ChangeSetMember
required: false
class_uri: cim:StaticVarCompensator