Skip to content

Class: StaticVarCompensator

_A facility for providing variable and controllable shunt reactive power. The SVC typically consists of a stepdown transformer, filter, thyristor-controlled reactor, and thyristor-switched capacitor arms. _

_ _

The SVC may operate in fixed MVar output mode or in voltage control mode. When in voltage control mode, the output of the SVC will be proportional to the deviation of voltage at the controlled bus from the voltage setpoint. The SVC characteristic slope defines the proportion. If the voltage at the controlled bus is equal to the voltage setpoint, the SVC MVar output is zero.

URI: cim:StaticVarCompensator

 classDiagram
    class StaticVarCompensator
      RegulatingCondEq <|-- StaticVarCompensator

      StaticVarCompensator : additional_equipment_container

          StaticVarCompensator --> EquipmentContainer : additional_equipment_container

      StaticVarCompensator : aggregate

      StaticVarCompensator : alias_name

      StaticVarCompensator : asset_datasheet

          StaticVarCompensator --> AssetInfo : asset_datasheet

      StaticVarCompensator : assets

          StaticVarCompensator --> Asset : assets

      StaticVarCompensator : base_voltage

          StaticVarCompensator --> BaseVoltage : base_voltage

      StaticVarCompensator : capacitive_rating

          StaticVarCompensator --> Reactance : capacitive_rating

      StaticVarCompensator : clearances

          StaticVarCompensator --> ClearanceDocument : clearances

      StaticVarCompensator : configuration_event

          StaticVarCompensator --> ConfigurationEvent : configuration_event

      StaticVarCompensator : contingency_equipment

          StaticVarCompensator --> ContingencyEquipment : contingency_equipment

      StaticVarCompensator : control_enabled

      StaticVarCompensator : controls

          StaticVarCompensator --> Control : controls

      StaticVarCompensator : description

      StaticVarCompensator : diagram_objects

          StaticVarCompensator --> DiagramObject : diagram_objects

      StaticVarCompensator : energy_component

          StaticVarCompensator --> EnergyComponent : energy_component

      StaticVarCompensator : eqiupment_limit_series_component

          StaticVarCompensator --> EquipmentLimitSeriesComponent : eqiupment_limit_series_component

      StaticVarCompensator : equipment_container

          StaticVarCompensator --> EquipmentContainer : equipment_container

      StaticVarCompensator : equipment_unavailability_schedule

          StaticVarCompensator --> EquipmentUnavailabilitySchedule : equipment_unavailability_schedule

      StaticVarCompensator : faults

          StaticVarCompensator --> Fault : faults

      StaticVarCompensator : generic_action

          StaticVarCompensator --> GenericAction : generic_action

      StaticVarCompensator : grounding_action

          StaticVarCompensator --> GroundAction : grounding_action

      StaticVarCompensator : in_service

      StaticVarCompensator : inductive_rating

          StaticVarCompensator --> Reactance : inductive_rating

      StaticVarCompensator : instance_set

          StaticVarCompensator --> InstanceSet : instance_set

      StaticVarCompensator : jumping_action

          StaticVarCompensator --> JumperAction : jumping_action

      StaticVarCompensator : limit_dependency_model

          StaticVarCompensator --> LimitDependency : limit_dependency_model

      StaticVarCompensator : location

          StaticVarCompensator --> Location : location

      StaticVarCompensator : m_rid

      StaticVarCompensator : measurements

          StaticVarCompensator --> Measurement : measurements

      StaticVarCompensator : names

          StaticVarCompensator --> Name : names

      StaticVarCompensator : network_analysis_enabled

      StaticVarCompensator : normally_in_service

      StaticVarCompensator : operating_share

          StaticVarCompensator --> OperatingShare : operating_share

      StaticVarCompensator : operational_limit_set

          StaticVarCompensator --> OperationalLimitSet : operational_limit_set

      StaticVarCompensator : operational_restrictions

          StaticVarCompensator --> OperationalRestriction : operational_restrictions

      StaticVarCompensator : operational_tags

          StaticVarCompensator --> OperationalTag : operational_tags

      StaticVarCompensator : outage

          StaticVarCompensator --> Outage : outage

      StaticVarCompensator : outages

          StaticVarCompensator --> Outage : outages

      StaticVarCompensator : pin_equipment

          StaticVarCompensator --> PinEquipment : pin_equipment

      StaticVarCompensator : properties_cimdata_object

          StaticVarCompensator --> ChangeSetMember : properties_cimdata_object

      StaticVarCompensator : protection_equipments

          StaticVarCompensator --> ProtectionEquipment : protection_equipments

      StaticVarCompensator : protective_action_adjustment

          StaticVarCompensator --> ProtectiveActionAdjustment : protective_action_adjustment

      StaticVarCompensator : protective_action_equipment

          StaticVarCompensator --> ProtectiveActionEquipment : protective_action_equipment

      StaticVarCompensator : psrevents

          StaticVarCompensator --> PSREvent : psrevents

      StaticVarCompensator : psrtype

          StaticVarCompensator --> PSRType : psrtype

      StaticVarCompensator : q

          StaticVarCompensator --> ReactivePower : q

      StaticVarCompensator : regulating_control

          StaticVarCompensator --> RegulatingControl : regulating_control

      StaticVarCompensator : reporting_group

          StaticVarCompensator --> ReportingGroup : reporting_group

      StaticVarCompensator : s_vccontrol_mode

          StaticVarCompensator --> SVCControlMode : s_vccontrol_mode

      StaticVarCompensator : slope

          StaticVarCompensator --> VoltagePerReactivePower : slope

      StaticVarCompensator : static_var_compensator_dynamics

          StaticVarCompensator --> StaticVarCompensatorDynamics : static_var_compensator_dynamics

      StaticVarCompensator : sv_status

          StaticVarCompensator --> SvStatus : sv_status

      StaticVarCompensator : targeting_cimdata_object

          StaticVarCompensator --> ChangeSetMember : targeting_cimdata_object

      StaticVarCompensator : terminals

          StaticVarCompensator --> Terminal : terminals

      StaticVarCompensator : usage_points

          StaticVarCompensator --> UsagePoint : usage_points

      StaticVarCompensator : verification_action

          StaticVarCompensator --> VerificationAction : verification_action

      StaticVarCompensator : voltage_set_point

          StaticVarCompensator --> Voltage : voltage_set_point

      StaticVarCompensator : weather_station

          StaticVarCompensator --> WeatherStation : weather_station

Inheritance

Slots

Name Cardinality and Range Description Inheritance
capacitive_rating 0..1
Reactance
Capacitive reactance at maximum capacitive reactive power direct
inductive_rating 0..1
Reactance
Inductive reactance at maximum inductive reactive power direct
q 0..1
ReactivePower
Reactive power injection direct
slope 0..1
VoltagePerReactivePower
The characteristics slope of an SVC defines how the reactive power output cha... direct
s_vccontrol_mode 0..1
SVCControlMode
SVC control mode direct
voltage_set_point 0..1
Voltage
The reactive power output of the SVC is proportional to the difference betwee... direct
static_var_compensator_dynamics 0..1
StaticVarCompensatorDynamics
Static Var Compensator dynamics model used to describe dynamic behaviour of t... direct
control_enabled 0..1
Boolean
Specifies the regulation status of the equipment RegulatingCondEq
regulating_control 0..1
RegulatingControl
The regulating control scheme in which this equipment participates RegulatingCondEq
energy_component 0..*
EnergyComponent
EnergyConnection
protective_action_adjustment 0..*
ProtectiveActionAdjustment
The operating condition to the Conducting Equipment is changed when protectiv... ConductingEquipment
sv_status 0..*
SvStatus
The status state variable associated with this conducting equipment ConductingEquipment
protection_equipments 0..*
ProtectionEquipment
Protection equipment used to protect specific conducting equipment ConductingEquipment
base_voltage 0..1
BaseVoltage
Base voltage of this conducting equipment ConductingEquipment
terminals 0..*
Terminal
Conducting equipment have terminals that may be connected to other conducting... ConductingEquipment
jumping_action 0..1
JumperAction
Jumper action involving jumping operation on this conducting equipment ConductingEquipment
grounding_action 0..1
GroundAction
Action involving grounding operation on this conducting equipment ConductingEquipment
outage 0..1
Outage
The outage that is isolated by the outage isolation equipment ConductingEquipment
aggregate 0..1
Boolean
The aggregate flag provides an alternative way of representing an aggregated ... Equipment
in_service 0..1
Boolean
Specifies the availability of the equipment Equipment
network_analysis_enabled 0..1
Boolean
The equipment is enabled to participate in network analysis Equipment
normally_in_service 0..1
Boolean
Specifies the availability of the equipment under normal operating conditions Equipment
weather_station 0..*
WeatherStation
Equipment
operational_limit_set 0..*
OperationalLimitSet
The operational limit sets associated with this equipment Equipment
contingency_equipment 0..*
ContingencyEquipment
The contingency equipments in which this equipment participates Equipment
equipment_container 0..1
EquipmentContainer
Container of this equipment Equipment
faults 0..*
Fault
All faults on this equipment Equipment
limit_dependency_model 0..*
LimitDependency
Limit dependencymodels organized under this equipment as a means for organizi... Equipment
eqiupment_limit_series_component 0..*
EquipmentLimitSeriesComponent
Equipment limit series calculation component to which this equipment contribu... Equipment
protective_action_equipment 0..*
ProtectiveActionEquipment
Protective action is controlling equipment Equipment
pin_equipment 0..*
PinEquipment
Equipment
equipment_unavailability_schedule 0..*
EquipmentUnavailabilitySchedule
Equipment
additional_equipment_container 0..*
EquipmentContainer
Additional equipment container beyond the primary equipment container Equipment
usage_points 0..*
UsagePoint
All usage points connected to the electrical grid through this equipment Equipment
outages 0..*
Outage
All outages in which this equipment is involved Equipment
operational_restrictions 0..*
OperationalRestriction
All operational restrictions for this equipment Equipment
controls 0..*
Control
The controller outputs used to actually govern a regulating device, e PowerSystemResource
measurements 0..*
Measurement
The measurements associated with this power system resource PowerSystemResource
psrtype 0..1
PSRType
Custom classification for this power system resource PowerSystemResource
configuration_event 0..*
ConfigurationEvent
All configuration events created for this Power System resource PowerSystemResource
reporting_group 0..*
ReportingGroup
Reporting groups to which this power system resource belongs PowerSystemResource
operating_share 0..*
OperatingShare
The operating shares of this power system resource PowerSystemResource
asset_datasheet 0..1
AssetInfo
Datasheet information for this power system resource PowerSystemResource
verification_action 0..*
VerificationAction
The verification action that is performed on the power system resource PowerSystemResource
clearances 0..*
ClearanceDocument
All clearances applicable to this power system resource PowerSystemResource
generic_action 0..*
GenericAction
The generic action that is performed on the power system resource PowerSystemResource
psrevents 0..*
PSREvent
All events associated with this power system resource PowerSystemResource
assets 0..*
Asset
All assets represented by this power system resource PowerSystemResource
location 0..1
Location
Location of this power system resource PowerSystemResource
operational_tags 0..*
OperationalTag
All operational tags placed on this power system resource PowerSystemResource
alias_name 0..1
String
The aliasName is free text human readable name of the object alternative to I... IdentifiedObject
description 0..1
String
The description is a free human readable text describing or naming the object IdentifiedObject
m_rid 0..1
String
Master resource identifier issued by a model authority IdentifiedObject
diagram_objects 0..*
DiagramObject
The diagram objects that are associated with the domain object IdentifiedObject
instance_set 1..1
InstanceSet
Dataset containing the data objects IdentifiedObject
names 0..*
Name
All names of this identified object IdentifiedObject
properties_cimdata_object 0..1
ChangeSetMember
The single CIM data object in the appropriate dataset context IdentifiedObject
targeting_cimdata_object 0..*
ChangeSetMember
Data objects registered IdentifiedObject

Usages

used by used in type used
StaticVarCompensatorDynamics static_var_compensator range StaticVarCompensator
SVCUserDefined static_var_compensator range StaticVarCompensator

Identifier and Mapping Information

Schema Source

  • from schema: https://cim.ucaiug.io/ns#TC57CIM

Mappings

Mapping Type Mapped Value
self cim:StaticVarCompensator
native cim:StaticVarCompensator

LinkML Source

Direct

name: StaticVarCompensator
description: "A facility for providing variable and controllable shunt reactive power.\
  \ The SVC typically consists of a stepdown transformer, filter, thyristor-controlled\
  \ reactor, and thyristor-switched capacitor arms.\r\n\r\nThe SVC may operate in\
  \ fixed MVar output mode or in voltage control mode. When in voltage control mode,\
  \ the output of the SVC will be proportional to the deviation of voltage at the\
  \ controlled bus from the voltage setpoint.  The SVC characteristic slope defines\
  \ the proportion.  If the voltage at the controlled bus is equal to the voltage\
  \ setpoint, the SVC MVar output is zero."
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
is_a: RegulatingCondEq
attributes:
  capacitive_rating:
    name: capacitive_rating
    description: Capacitive reactance at maximum capacitive reactive power.  Shall
      always be positive.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:StaticVarCompensator.capacitiveRating
    multivalued: false
    domain_of:
    - StaticVarCompensator
    - SVC
    range: Reactance
    required: false
  inductive_rating:
    name: inductive_rating
    description: 'Inductive reactance at maximum inductive reactive power.  Shall
      always be negative.  '
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:StaticVarCompensator.inductiveRating
    multivalued: false
    domain_of:
    - StaticVarCompensator
    - SVC
    range: Reactance
    required: false
  q:
    name: q
    description: "Reactive power injection. Load sign convention is used, i.e. positive\
      \ sign means flow out from a node.\r\nStarting value for a steady state solution."
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:StaticVarCompensator.q
    multivalued: false
    domain_of:
    - SvPowerFlow
    - RotatingMachine
    - EquivalentInjection
    - PowerElectronicsConnection
    - PowerElectronicsConnectionPhase
    - ACDCConverter
    - EnergyConsumerPhase
    - EnergyConsumer
    - StaticVarCompensator
    - ExternalNetworkInjection
    - UnderexcLimIEEE2
    - UnderexcLim2Simplified
    range: ReactivePower
    required: false
  slope:
    name: slope
    description: "The characteristics slope of an SVC defines how the reactive power\
      \ output changes in proportion to the difference between the regulated bus voltage\
      \ and the voltage setpoint.\r\nThe attribute shall be a positive value or zero."
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:StaticVarCompensator.slope
    multivalued: false
    domain_of:
    - StaticVarCompensator
    range: VoltagePerReactivePower
    required: false
  s_vccontrol_mode:
    name: s_vccontrol_mode
    description: SVC control mode.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:StaticVarCompensator.sVCControlMode
    multivalued: false
    domain_of:
    - StaticVarCompensator
    range: SVCControlMode
    required: false
  voltage_set_point:
    name: voltage_set_point
    description: The reactive power output of the SVC is proportional to the difference
      between the voltage at the regulated bus and the voltage setpoint.  When the
      regulated bus voltage is equal to the voltage setpoint, the reactive power output
      is zero.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:StaticVarCompensator.voltageSetPoint
    multivalued: false
    domain_of:
    - StaticVarCompensator
    range: Voltage
    required: false
  static_var_compensator_dynamics:
    name: static_var_compensator_dynamics
    description: Static Var Compensator dynamics model used to describe dynamic behaviour
      of this Static Var Compensator.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:StaticVarCompensator.StaticVarCompensatorDynamics
    multivalued: false
    domain_of:
    - StaticVarCompensator
    range: StaticVarCompensatorDynamics
    required: false
class_uri: cim:StaticVarCompensator

Induced

name: StaticVarCompensator
description: "A facility for providing variable and controllable shunt reactive power.\
  \ The SVC typically consists of a stepdown transformer, filter, thyristor-controlled\
  \ reactor, and thyristor-switched capacitor arms.\r\n\r\nThe SVC may operate in\
  \ fixed MVar output mode or in voltage control mode. When in voltage control mode,\
  \ the output of the SVC will be proportional to the deviation of voltage at the\
  \ controlled bus from the voltage setpoint.  The SVC characteristic slope defines\
  \ the proportion.  If the voltage at the controlled bus is equal to the voltage\
  \ setpoint, the SVC MVar output is zero."
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
is_a: RegulatingCondEq
attributes:
  capacitive_rating:
    name: capacitive_rating
    description: Capacitive reactance at maximum capacitive reactive power.  Shall
      always be positive.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:StaticVarCompensator.capacitiveRating
    multivalued: false
    alias: capacitive_rating
    owner: StaticVarCompensator
    domain_of:
    - StaticVarCompensator
    - SVC
    range: Reactance
    required: false
  inductive_rating:
    name: inductive_rating
    description: 'Inductive reactance at maximum inductive reactive power.  Shall
      always be negative.  '
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:StaticVarCompensator.inductiveRating
    multivalued: false
    alias: inductive_rating
    owner: StaticVarCompensator
    domain_of:
    - StaticVarCompensator
    - SVC
    range: Reactance
    required: false
  q:
    name: q
    description: "Reactive power injection. Load sign convention is used, i.e. positive\
      \ sign means flow out from a node.\r\nStarting value for a steady state solution."
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:StaticVarCompensator.q
    multivalued: false
    alias: q
    owner: StaticVarCompensator
    domain_of:
    - SvPowerFlow
    - RotatingMachine
    - EquivalentInjection
    - PowerElectronicsConnection
    - PowerElectronicsConnectionPhase
    - ACDCConverter
    - EnergyConsumerPhase
    - EnergyConsumer
    - StaticVarCompensator
    - ExternalNetworkInjection
    - UnderexcLimIEEE2
    - UnderexcLim2Simplified
    range: ReactivePower
    required: false
  slope:
    name: slope
    description: "The characteristics slope of an SVC defines how the reactive power\
      \ output changes in proportion to the difference between the regulated bus voltage\
      \ and the voltage setpoint.\r\nThe attribute shall be a positive value or zero."
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:StaticVarCompensator.slope
    multivalued: false
    alias: slope
    owner: StaticVarCompensator
    domain_of:
    - StaticVarCompensator
    range: VoltagePerReactivePower
    required: false
  s_vccontrol_mode:
    name: s_vccontrol_mode
    description: SVC control mode.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:StaticVarCompensator.sVCControlMode
    multivalued: false
    alias: s_vccontrol_mode
    owner: StaticVarCompensator
    domain_of:
    - StaticVarCompensator
    range: SVCControlMode
    required: false
  voltage_set_point:
    name: voltage_set_point
    description: The reactive power output of the SVC is proportional to the difference
      between the voltage at the regulated bus and the voltage setpoint.  When the
      regulated bus voltage is equal to the voltage setpoint, the reactive power output
      is zero.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:StaticVarCompensator.voltageSetPoint
    multivalued: false
    alias: voltage_set_point
    owner: StaticVarCompensator
    domain_of:
    - StaticVarCompensator
    range: Voltage
    required: false
  static_var_compensator_dynamics:
    name: static_var_compensator_dynamics
    description: Static Var Compensator dynamics model used to describe dynamic behaviour
      of this Static Var Compensator.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:StaticVarCompensator.StaticVarCompensatorDynamics
    multivalued: false
    alias: static_var_compensator_dynamics
    owner: StaticVarCompensator
    domain_of:
    - StaticVarCompensator
    range: StaticVarCompensatorDynamics
    required: false
  control_enabled:
    name: control_enabled
    description: Specifies the regulation status of the equipment.  True is regulating,
      false is not regulating.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegulatingCondEq.controlEnabled
    multivalued: false
    alias: control_enabled
    owner: StaticVarCompensator
    domain_of:
    - RegulatingCondEq
    - TapChanger
    range: boolean
    required: false
  regulating_control:
    name: regulating_control
    description: The regulating control scheme in which this equipment participates.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:RegulatingCondEq.RegulatingControl
    multivalued: false
    alias: regulating_control
    owner: StaticVarCompensator
    domain_of:
    - Terminal
    - RegulatingCondEq
    - RegulationSchedule
    - ProtectiveActionRegulation
    range: RegulatingControl
    required: false
  energy_component:
    name: energy_component
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:EnergyConnection.EnergyComponent
    multivalued: true
    alias: energy_component
    owner: StaticVarCompensator
    domain_of:
    - EnergyGroup
    - EnergyConnection
    range: EnergyComponent
    required: false
  protective_action_adjustment:
    name: protective_action_adjustment
    description: 'The operating condition to the Conducting Equipment is changed when
      protective action adjustment is activated. For ShuntCompensator or other conducting
      equipment that operates on discrete values (integer), the values given in float
      will be rounded. '
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:ConductingEquipment.ProtectiveActionAdjustment
    multivalued: true
    alias: protective_action_adjustment
    owner: StaticVarCompensator
    domain_of:
    - Measurement
    - ConductingEquipment
    - DCConductingEquipment
    range: ProtectiveActionAdjustment
    required: false
  sv_status:
    name: sv_status
    description: The status state variable associated with this conducting equipment.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:ConductingEquipment.SvStatus
    multivalued: true
    alias: sv_status
    owner: StaticVarCompensator
    domain_of:
    - ConductingEquipment
    range: SvStatus
    required: false
  protection_equipments:
    name: protection_equipments
    description: 'Protection equipment  used to protect specific conducting equipment. '
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:ConductingEquipment.ProtectionEquipments
    multivalued: true
    alias: protection_equipments
    owner: StaticVarCompensator
    domain_of:
    - ConductingEquipment
    range: ProtectionEquipment
    required: false
  base_voltage:
    name: base_voltage
    description: Base voltage of this conducting equipment.  Use only when there is
      no voltage level container used and only one base voltage applies.  For example,
      not used for transformers.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:ConductingEquipment.BaseVoltage
    multivalued: false
    alias: base_voltage
    owner: StaticVarCompensator
    domain_of:
    - TopologicalNode
    - TransformerEnd
    - ConductingEquipment
    - VoltageLevel
    - AssetDeployment
    range: BaseVoltage
    required: false
  terminals:
    name: terminals
    description: Conducting equipment have terminals that may be connected to other
      conducting equipment terminals via connectivity nodes or topological nodes.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:ConductingEquipment.Terminals
    multivalued: true
    alias: terminals
    owner: StaticVarCompensator
    domain_of:
    - ConnectivityNode
    - ConductingEquipment
    range: Terminal
    required: false
  jumping_action:
    name: jumping_action
    description: Jumper action involving jumping operation on this conducting equipment.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:ConductingEquipment.JumpingAction
    multivalued: false
    alias: jumping_action
    owner: StaticVarCompensator
    domain_of:
    - ConductingEquipment
    range: JumperAction
    required: false
  grounding_action:
    name: grounding_action
    description: Action involving grounding operation on this conducting equipment.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:ConductingEquipment.GroundingAction
    multivalued: false
    alias: grounding_action
    owner: StaticVarCompensator
    domain_of:
    - ConductingEquipment
    range: GroundAction
    required: false
  outage:
    name: outage
    description: The outage that is isolated by the outage isolation equipment.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:ConductingEquipment.Outage
    multivalued: false
    alias: outage
    owner: StaticVarCompensator
    domain_of:
    - Incident
    - SwitchingPlan
    - UsagePoint
    - ConductingEquipment
    - Crew
    - EstimatedRestorationTime
    - OutageArea
    - Fault
    range: Outage
    required: false
  aggregate:
    name: aggregate
    description: "The aggregate flag provides an alternative way of representing an\
      \ aggregated (equivalent) element. It is applicable in cases when the dedicated\
      \ classes for equivalent equipment do not have all of the attributes necessary\
      \ to represent the required level of detail.  In case the flag is set to “true”\
      \ the single instance of equipment represents multiple pieces of equipment that\
      \ have been modelled together as an aggregate equivalent obtained by a network\
      \ reduction procedure. Examples would be power transformers or synchronous machines\
      \ operating in parallel modelled as a single aggregate power transformer or\
      \ aggregate synchronous machine.  \r\nThe attribute is not used for EquivalentBranch,\
      \ EquivalentShunt and EquivalentInjection."
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Equipment.aggregate
    multivalued: false
    alias: aggregate
    owner: StaticVarCompensator
    domain_of:
    - Equipment
    - ReadingType
    range: boolean
    required: false
  in_service:
    name: in_service
    description: Specifies the availability of the equipment. True means the equipment
      is available for topology processing, which determines if the equipment is energized
      or not. False means that the equipment is treated by network applications as
      if it is not in the model.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Equipment.inService
    multivalued: false
    alias: in_service
    owner: StaticVarCompensator
    domain_of:
    - Equipment
    - SvStatus
    - ProtectiveActionEquipment
    range: boolean
    required: false
  network_analysis_enabled:
    name: network_analysis_enabled
    description: The equipment is enabled to participate in network analysis.  If
      unspecified, the value is assumed to be true.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Equipment.networkAnalysisEnabled
    multivalued: false
    alias: network_analysis_enabled
    owner: StaticVarCompensator
    domain_of:
    - Equipment
    range: boolean
    required: false
  normally_in_service:
    name: normally_in_service
    description: Specifies the availability of the equipment under normal operating
      conditions. True means the equipment is available for topology processing, which
      determines if the equipment is energized or not. False means that the equipment
      is treated by network applications as if it is not in the model.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Equipment.normallyInService
    multivalued: false
    alias: normally_in_service
    owner: StaticVarCompensator
    domain_of:
    - Equipment
    range: boolean
    required: false
  weather_station:
    name: weather_station
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Equipment.WeatherStation
    multivalued: true
    alias: weather_station
    owner: StaticVarCompensator
    domain_of:
    - Equipment
    range: WeatherStation
    required: false
  operational_limit_set:
    name: operational_limit_set
    description: The operational limit sets associated with this equipment.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:Equipment.OperationalLimitSet
    multivalued: true
    alias: operational_limit_set
    owner: StaticVarCompensator
    domain_of:
    - ACDCTerminal
    - OperationalLimit
    - Equipment
    range: OperationalLimitSet
    required: false
  contingency_equipment:
    name: contingency_equipment
    description: The contingency equipments in which this equipment participates.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Equipment.ContingencyEquipment
    multivalued: true
    alias: contingency_equipment
    owner: StaticVarCompensator
    domain_of:
    - Equipment
    range: ContingencyEquipment
    required: false
  equipment_container:
    name: equipment_container
    description: Container of this equipment.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Equipment.EquipmentContainer
    multivalued: false
    alias: equipment_container
    owner: StaticVarCompensator
    domain_of:
    - Equipment
    range: EquipmentContainer
    required: false
  faults:
    name: faults
    description: All faults on this equipment.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Equipment.Faults
    multivalued: true
    alias: faults
    owner: StaticVarCompensator
    domain_of:
    - Equipment
    - Outage
    - FaultCauseType
    range: Fault
    required: false
  limit_dependency_model:
    name: limit_dependency_model
    description: Limit dependencymodels organized under this equipment as a means
      for organizing the model in a tree view.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:Equipment.LimitDependencyModel
    multivalued: true
    alias: limit_dependency_model
    owner: StaticVarCompensator
    domain_of:
    - OperationalLimit
    - Equipment
    range: LimitDependency
    required: false
  eqiupment_limit_series_component:
    name: eqiupment_limit_series_component
    description: Equipment limit series calculation component to which this equipment
      contributes.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Equipment.EqiupmentLimitSeriesComponent
    multivalued: true
    alias: eqiupment_limit_series_component
    owner: StaticVarCompensator
    domain_of:
    - Equipment
    range: EquipmentLimitSeriesComponent
    required: false
  protective_action_equipment:
    name: protective_action_equipment
    description: Protective action is controlling equipment. This can be direct signals
      from the control center, or emulation of action done by protection equipment.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Equipment.ProtectiveActionEquipment
    multivalued: true
    alias: protective_action_equipment
    owner: StaticVarCompensator
    domain_of:
    - Equipment
    range: ProtectiveActionEquipment
    required: false
  pin_equipment:
    name: pin_equipment
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Equipment.PinEquipment
    multivalued: true
    alias: pin_equipment
    owner: StaticVarCompensator
    domain_of:
    - Equipment
    range: PinEquipment
    required: false
  equipment_unavailability_schedule:
    name: equipment_unavailability_schedule
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Equipment.EquipmentUnavailabilitySchedule
    multivalued: true
    alias: equipment_unavailability_schedule
    owner: StaticVarCompensator
    domain_of:
    - Equipment
    - UnavailabilitySwitchAction
    - UnavailablitySchedule
    range: EquipmentUnavailabilitySchedule
    required: false
  additional_equipment_container:
    name: additional_equipment_container
    description: Additional equipment container beyond the primary equipment container.  The
      equipment is contained in another equipment container, but also grouped with
      this equipment container.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Equipment.AdditionalEquipmentContainer
    multivalued: true
    alias: additional_equipment_container
    owner: StaticVarCompensator
    domain_of:
    - Equipment
    range: EquipmentContainer
    required: false
  usage_points:
    name: usage_points
    description: All usage points connected to the electrical grid through this equipment.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Equipment.UsagePoints
    multivalued: true
    alias: usage_points
    owner: StaticVarCompensator
    domain_of:
    - Equipment
    - CustomerAgreement
    - ServiceCategory
    - PricingStructure
    - EndDeviceControl
    - UsagePointGroup
    - ServiceLocation
    - MetrologyRequirement
    - ServiceSupplier
    - UsagePointLocation
    range: UsagePoint
    required: false
  outages:
    name: outages
    description: All outages in which this equipment is involved.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Equipment.Outages
    multivalued: true
    alias: outages
    owner: StaticVarCompensator
    domain_of:
    - Equipment
    range: Outage
    required: false
  operational_restrictions:
    name: operational_restrictions
    description: All operational restrictions for this equipment.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Equipment.OperationalRestrictions
    multivalued: true
    alias: operational_restrictions
    owner: StaticVarCompensator
    domain_of:
    - Equipment
    - ProductAssetModel
    range: OperationalRestriction
    required: false
  controls:
    name: controls
    description: The controller outputs used to actually govern a regulating device,
      e.g. the magnetization of a synchronous machine or capacitor bank breaker actuator.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PowerSystemResource.Controls
    multivalued: true
    alias: controls
    owner: StaticVarCompensator
    domain_of:
    - PowerSystemResource
    - HostControlArea
    range: Control
    required: false
  measurements:
    name: measurements
    description: The measurements associated with this power system resource.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PowerSystemResource.Measurements
    multivalued: true
    alias: measurements
    owner: StaticVarCompensator
    domain_of:
    - PowerSystemResource
    - ACDCTerminal
    - Asset
    - Location
    - Procedure
    - AnalogLimitSet
    - AccumulatorLimitSet
    range: Measurement
    required: false
  psrtype:
    name: psrtype
    description: Custom classification for this power system resource.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PowerSystemResource.PSRType
    multivalued: false
    alias: psrtype
    owner: StaticVarCompensator
    domain_of:
    - PowerSystemResource
    range: PSRType
    required: false
  configuration_event:
    name: configuration_event
    description: All configuration events created for this Power System resource.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PowerSystemResource.ConfigurationEvent
    multivalued: true
    alias: configuration_event
    owner: StaticVarCompensator
    domain_of:
    - PowerSystemResource
    - FaultCauseType
    range: ConfigurationEvent
    required: false
  reporting_group:
    name: reporting_group
    description: Reporting groups to which this power system resource belongs.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PowerSystemResource.ReportingGroup
    multivalued: true
    alias: reporting_group
    owner: StaticVarCompensator
    domain_of:
    - PowerSystemResource
    - BusNameMarker
    - TopologicalNode
    - ReportingSuperGroup
    range: ReportingGroup
    required: false
  operating_share:
    name: operating_share
    description: The operating shares of this power system resource.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PowerSystemResource.OperatingShare
    multivalued: true
    alias: operating_share
    owner: StaticVarCompensator
    domain_of:
    - PowerSystemResource
    - OperatingParticipant
    range: OperatingShare
    required: false
  asset_datasheet:
    name: asset_datasheet
    description: Datasheet information for this power system resource.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PowerSystemResource.AssetDatasheet
    multivalued: false
    alias: asset_datasheet
    owner: StaticVarCompensator
    domain_of:
    - PowerSystemResource
    range: AssetInfo
    required: false
  verification_action:
    name: verification_action
    description: The verification action that is performed on the power system resource
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PowerSystemResource.VerificationAction
    multivalued: true
    alias: verification_action
    owner: StaticVarCompensator
    domain_of:
    - PowerSystemResource
    range: VerificationAction
    required: false
  clearances:
    name: clearances
    description: All clearances applicable to this power system resource.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PowerSystemResource.Clearances
    multivalued: true
    alias: clearances
    owner: StaticVarCompensator
    domain_of:
    - PowerSystemResource
    range: ClearanceDocument
    required: false
  generic_action:
    name: generic_action
    description: The generic action that is performed on the power system resource
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PowerSystemResource.GenericAction
    multivalued: true
    alias: generic_action
    owner: StaticVarCompensator
    domain_of:
    - PowerSystemResource
    range: GenericAction
    required: false
  psrevents:
    name: psrevents
    description: All events associated with this power system resource.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PowerSystemResource.PSREvents
    multivalued: true
    alias: psrevents
    owner: StaticVarCompensator
    domain_of:
    - PowerSystemResource
    range: PSREvent
    required: false
  assets:
    name: assets
    description: All assets represented by this power system resource. For example,
      multiple conductor assets are electrically modelled as a single AC line segment.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PowerSystemResource.Assets
    multivalued: true
    alias: assets
    owner: StaticVarCompensator
    domain_of:
    - PowerSystemResource
    - AssetInfo
    - Location
    - WorkTask
    - ErpRecDelvLineItem
    - AssetContainer
    - ActivityRecord
    - Procedure
    - ReliabilityInfo
    - AssetPropertyCurve
    - AssetOrganisationRole
    - ScheduledEvent
    range: Asset
    required: false
  location:
    name: location
    description: Location of this power system resource.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PowerSystemResource.Location
    multivalued: false
    alias: location
    owner: StaticVarCompensator
    domain_of:
    - PowerSystemResource
    - Asset
    - Incident
    - SwitchingOrder
    - TroubleOrder
    - Crew
    - Fault
    - PointOfSale
    - TroubleTicket
    - OutageOrder
    - EnvironmentalMonitoringStation
    - EnvironmentalLocationType
    - PositionPoint
    - FailureEvent
    range: Location
    required: false
  operational_tags:
    name: operational_tags
    description: All operational tags placed on this power system resource.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PowerSystemResource.OperationalTags
    multivalued: true
    alias: operational_tags
    owner: StaticVarCompensator
    domain_of:
    - PowerSystemResource
    - Asset
    range: OperationalTag
    required: false
  alias_name:
    name: alias_name
    description: "The aliasName is free text human readable name of the object alternative\
      \ to IdentifiedObject.name. It may be non unique and may not correlate to a\
      \ naming hierarchy.\r\nThe attribute aliasName is retained because of backwards\
      \ compatibility between CIM relases. It is however recommended to replace aliasName\
      \ with the Name class as aliasName is planned for retirement at a future time.\r\
      \n\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.aliasName
    multivalued: false
    alias: alias_name
    owner: StaticVarCompensator
    domain_of:
    - IdentifiedObject
    range: string
    required: false
  description:
    name: description
    description: The description is a free human readable text describing or naming
      the object. It may be non unique and may not correlate to a naming hierarchy.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.description
    multivalued: false
    alias: description
    owner: StaticVarCompensator
    domain_of:
    - IdentifiedObject
    - NameType
    - NameTypeAuthority
    - DataSet
    - SwitchingStepGroup
    - AreaReserveSpec
    range: string
    required: false
  m_rid:
    name: m_rid
    description: "Master resource identifier issued by a model authority. The mRID\
      \ is unique within an exchange context. Global uniqueness is easily achieved\
      \ by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is\
      \ strongly recommended.\r\nFor CIMXML data files in RDF syntax conforming to\
      \ IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify\
      \ CIM object elements."
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.mRID
    multivalued: false
    alias: m_rid
    owner: StaticVarCompensator
    domain_of:
    - IdentifiedObject
    - DataSet
    range: string
    required: false
  diagram_objects:
    name: diagram_objects
    description: The diagram objects that are associated with the domain object.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.DiagramObjects
    multivalued: true
    alias: diagram_objects
    owner: StaticVarCompensator
    domain_of:
    - IdentifiedObject
    range: DiagramObject
    required: false
  instance_set:
    name: instance_set
    description: Dataset containing the data objects.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.InstanceSet
    multivalued: false
    alias: instance_set
    owner: StaticVarCompensator
    domain_of:
    - IdentifiedObject
    range: InstanceSet
    required: true
  names:
    name: names
    description: All names of this identified object.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.Names
    multivalued: true
    alias: names
    owner: StaticVarCompensator
    domain_of:
    - IdentifiedObject
    - NameType
    range: Name
    required: false
  properties_cimdata_object:
    name: properties_cimdata_object
    description: The single CIM data object in the appropriate dataset context.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.PropertiesCIMDataObject
    multivalued: false
    alias: properties_cimdata_object
    owner: StaticVarCompensator
    domain_of:
    - IdentifiedObject
    range: ChangeSetMember
    required: false
  targeting_cimdata_object:
    name: targeting_cimdata_object
    description: Data objects registered.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.TargetingCIMDataObject
    multivalued: true
    alias: targeting_cimdata_object
    owner: StaticVarCompensator
    domain_of:
    - IdentifiedObject
    range: ChangeSetMember
    required: false
class_uri: cim:StaticVarCompensator