Skip to content

Class: RegisteredGenerator

Model of a generator that is registered to participate in the market.

URI: cim:RegisteredGenerator

 classDiagram
    class RegisteredGenerator
      RegisteredResource <|-- RegisteredGenerator


      RegisteredGenerator <|-- CombinedCycleConfiguration


      RegisteredGenerator : acaflag

          RegisteredGenerator --> YesNo : acaflag

      RegisteredGenerator : adjacent_caset

          RegisteredGenerator --> AdjacentCASet : adjacent_caset

      RegisteredGenerator : aggregate_node

          RegisteredGenerator --> AggregateNode : aggregate_node

      RegisteredGenerator : alias_name

      RegisteredGenerator : allocation_result_values

          RegisteredGenerator --> AllocationResultValues : allocation_result_values

      RegisteredGenerator : asset_datasheet

          RegisteredGenerator --> AssetInfo : asset_datasheet

      RegisteredGenerator : assets

          RegisteredGenerator --> Asset : assets

      RegisteredGenerator : asspoptimization_flag

          RegisteredGenerator --> YesNo : asspoptimization_flag

      RegisteredGenerator : auxillary_object

          RegisteredGenerator --> AuxiliaryObject : auxillary_object

      RegisteredGenerator : capacity_factor

          RegisteredGenerator --> PerCent : capacity_factor

      RegisteredGenerator : clearances

          RegisteredGenerator --> ClearanceDocument : clearances

      RegisteredGenerator : cold_start_time

      RegisteredGenerator : combined_cycle_operating_mode

      RegisteredGenerator : commercial_op_date

      RegisteredGenerator : commericial_operation_date

      RegisteredGenerator : commitments

          RegisteredGenerator --> Commitments : commitments

      RegisteredGenerator : configuration_event

          RegisteredGenerator --> ConfigurationEvent : configuration_event

      RegisteredGenerator : constrained_output_flag

          RegisteredGenerator --> YesNo : constrained_output_flag

      RegisteredGenerator : contingency_avail_flag

          RegisteredGenerator --> YesNo : contingency_avail_flag

      RegisteredGenerator : contract_distribution_factor

          RegisteredGenerator --> ContractDistributionFactor : contract_distribution_factor

      RegisteredGenerator : control_area_designation

          RegisteredGenerator --> ControlAreaDesignation : control_area_designation

      RegisteredGenerator : controls

          RegisteredGenerator --> Control : controls

      RegisteredGenerator : default_bid

          RegisteredGenerator --> DefaultBid : default_bid

      RegisteredGenerator : description

      RegisteredGenerator : diagram_objects

          RegisteredGenerator --> DiagramObject : diagram_objects

      RegisteredGenerator : dispatch_inst_reply

          RegisteredGenerator --> DispatchInstReply : dispatch_inst_reply

      RegisteredGenerator : dispatchable

      RegisteredGenerator : domain

          RegisteredGenerator --> Domain : domain

      RegisteredGenerator : dop_instruction

          RegisteredGenerator --> DopInstruction : dop_instruction

      RegisteredGenerator : dot_instruction

          RegisteredGenerator --> DotInstruction : dot_instruction

      RegisteredGenerator : ecaflag

          RegisteredGenerator --> YesNo : ecaflag

      RegisteredGenerator : energy_down_ramp_rate

          RegisteredGenerator --> ActivePowerChangeRate : energy_down_ramp_rate

      RegisteredGenerator : energy_markets

          RegisteredGenerator --> EnergyMarket : energy_markets

      RegisteredGenerator : energy_price_index

          RegisteredGenerator --> EnergyPriceIndex : energy_price_index

      RegisteredGenerator : energy_up_ramp_rate

          RegisteredGenerator --> ActivePowerChangeRate : energy_up_ramp_rate

      RegisteredGenerator : ex_post_resource_results

          RegisteredGenerator --> ExPostResourceResults : ex_post_resource_results

      RegisteredGenerator : expected_energy_values

          RegisteredGenerator --> ExpectedEnergyValues : expected_energy_values

      RegisteredGenerator : extreme_long_start

          RegisteredGenerator --> YesNo : extreme_long_start

      RegisteredGenerator : flexible_offer_flag

          RegisteredGenerator --> YesNo : flexible_offer_flag

      RegisteredGenerator : forbidden_region

          RegisteredGenerator --> ForbiddenRegion : forbidden_region

      RegisteredGenerator : former_reference

          RegisteredGenerator --> FormerReference : former_reference

      RegisteredGenerator : fuel_cost_curve

          RegisteredGenerator --> FuelCostCurve : fuel_cost_curve

      RegisteredGenerator : fuel_region

          RegisteredGenerator --> FuelRegion : fuel_region

      RegisteredGenerator : fuel_source

          RegisteredGenerator --> FuelSource : fuel_source

      RegisteredGenerator : generating_bids

          RegisteredGenerator --> GeneratingBid : generating_bids

      RegisteredGenerator : generic_action

          RegisteredGenerator --> GenericAction : generic_action

      RegisteredGenerator : high_control_limit

          RegisteredGenerator --> ActivePower : high_control_limit

      RegisteredGenerator : host_control_area

          RegisteredGenerator --> HostControlArea : host_control_area

      RegisteredGenerator : hot_int_time

      RegisteredGenerator : hot_start_time

      RegisteredGenerator : hourly_predispatch

          RegisteredGenerator --> YesNo : hourly_predispatch

      RegisteredGenerator : instance_set

          RegisteredGenerator --> InstanceSet : instance_set

      RegisteredGenerator : instructions

          RegisteredGenerator --> Instructions : instructions

      RegisteredGenerator : int_cold_time

      RegisteredGenerator : int_start_time

      RegisteredGenerator : inter_tie

          RegisteredGenerator --> SchedulingPoint : inter_tie

      RegisteredGenerator : intermittent_resource_eligibility

          RegisteredGenerator --> IntermittentResourceEligibility : intermittent_resource_eligibility

      RegisteredGenerator : is_aggregated_res

          RegisteredGenerator --> YesNo : is_aggregated_res

      RegisteredGenerator : last_modified

      RegisteredGenerator : lmpmflag

          RegisteredGenerator --> YesNo : lmpmflag

      RegisteredGenerator : load_following_down_mss

          RegisteredGenerator --> YesNo : load_following_down_mss

      RegisteredGenerator : load_following_inst

          RegisteredGenerator --> LoadFollowingInst : load_following_inst

      RegisteredGenerator : load_following_operator_input

          RegisteredGenerator --> LoadFollowingOperatorInput : load_following_operator_input

      RegisteredGenerator : load_following_up_mss

          RegisteredGenerator --> YesNo : load_following_up_mss

      RegisteredGenerator : local_reliability_area

          RegisteredGenerator --> LocalReliabilityArea : local_reliability_area

      RegisteredGenerator : location

          RegisteredGenerator --> Location : location

      RegisteredGenerator : low_control_limit

          RegisteredGenerator --> ActivePower : low_control_limit

      RegisteredGenerator : m_rid

      RegisteredGenerator : market_object_status

          RegisteredGenerator --> MarketObjectStatus : market_object_status

      RegisteredGenerator : market_participant

          RegisteredGenerator --> MarketParticipant : market_participant

      RegisteredGenerator : market_participation_flag

          RegisteredGenerator --> YesNo : market_participation_flag

      RegisteredGenerator : max_base_self_sched_qty

      RegisteredGenerator : max_dependable_cap

          RegisteredGenerator --> ActivePower : max_dependable_cap

      RegisteredGenerator : max_min_load_cost

          RegisteredGenerator --> CostRate : max_min_load_cost

      RegisteredGenerator : max_on_time

      RegisteredGenerator : max_pumping_level

          RegisteredGenerator --> ActivePower : max_pumping_level

      RegisteredGenerator : max_shutdown_time

      RegisteredGenerator : max_start_ups_per_day

      RegisteredGenerator : max_weekly_energy

      RegisteredGenerator : max_weekly_starts

      RegisteredGenerator : maximum_allowable_spinning_reserve

          RegisteredGenerator --> ActivePower : maximum_allowable_spinning_reserve

      RegisteredGenerator : maximum_operating_limit

          RegisteredGenerator --> ActivePower : maximum_operating_limit

      RegisteredGenerator : measurements

          RegisteredGenerator --> Measurement : measurements

      RegisteredGenerator : min_dispatch_time

          RegisteredGenerator --> Hours : min_dispatch_time

      RegisteredGenerator : min_load_cost

          RegisteredGenerator --> CostRate : min_load_cost

      RegisteredGenerator : min_off_time

      RegisteredGenerator : min_on_time

      RegisteredGenerator : minimum_load_cost_basis

          RegisteredGenerator --> CostBasis : minimum_load_cost_basis

      RegisteredGenerator : minimum_load_fuel_cost

          RegisteredGenerator --> CostPerHeatUnit : minimum_load_fuel_cost

      RegisteredGenerator : minimum_operating_limit

          RegisteredGenerator --> ActivePower : minimum_operating_limit

      RegisteredGenerator : mkt_connectivity_node

          RegisteredGenerator --> MktConnectivityNode : mkt_connectivity_node

      RegisteredGenerator : mkt_heat_rate_curve

          RegisteredGenerator --> MktHeatRateCurve : mkt_heat_rate_curve

      RegisteredGenerator : mpmresource_status

          RegisteredGenerator --> MPMResourceStatus : mpmresource_status

      RegisteredGenerator : mpmtest_threshold

          RegisteredGenerator --> MPMTestThreshold : mpmtest_threshold

      RegisteredGenerator : must_offer_flag

          RegisteredGenerator --> YesNo : must_offer_flag

      RegisteredGenerator : must_offer_ra

          RegisteredGenerator --> YesNo : must_offer_ra

      RegisteredGenerator : nameplate_capacity

          RegisteredGenerator --> ActivePower : nameplate_capacity

      RegisteredGenerator : names

          RegisteredGenerator --> Name : names

      RegisteredGenerator : non_market

          RegisteredGenerator --> YesNo : non_market

      RegisteredGenerator : operating_maintenance_cost

          RegisteredGenerator --> CostPerEnergyUnit : operating_maintenance_cost

      RegisteredGenerator : operating_share

          RegisteredGenerator --> OperatingShare : operating_share

      RegisteredGenerator : operational_tags

          RegisteredGenerator --> OperationalTag : operational_tags

      RegisteredGenerator : org_res_ownership

          RegisteredGenerator --> OrgResOwnership : org_res_ownership

      RegisteredGenerator : pnode

          RegisteredGenerator --> Pnode : pnode

      RegisteredGenerator : point_of_delivery_flag

          RegisteredGenerator --> YesNo : point_of_delivery_flag

      RegisteredGenerator : price_set_flag_da

          RegisteredGenerator --> YesNo : price_set_flag_da

      RegisteredGenerator : price_set_flag_rt

          RegisteredGenerator --> YesNo : price_set_flag_rt

      RegisteredGenerator : properties_cimdata_object

          RegisteredGenerator --> ChangeSetMember : properties_cimdata_object

      RegisteredGenerator : psrevents

          RegisteredGenerator --> PSREvent : psrevents

      RegisteredGenerator : psrtype

          RegisteredGenerator --> PSRType : psrtype

      RegisteredGenerator : pump_min_down_time

      RegisteredGenerator : pump_min_up_time

      RegisteredGenerator : pump_shutdown_cost

      RegisteredGenerator : pump_shutdown_time

      RegisteredGenerator : pumping_cost

          RegisteredGenerator --> CostRate : pumping_cost

      RegisteredGenerator : pumping_factor

      RegisteredGenerator : quick_start_flag

          RegisteredGenerator --> YesNo : quick_start_flag

      RegisteredGenerator : ramp_curve_type

          RegisteredGenerator --> RampCurveType : ramp_curve_type

      RegisteredGenerator : ramp_rate_curve

          RegisteredGenerator --> RampRateCurve : ramp_rate_curve

      RegisteredGenerator : reason

          RegisteredGenerator --> Reason : reason

      RegisteredGenerator : registration_status

          RegisteredGenerator --> ResourceRegistrationStatus : registration_status

      RegisteredGenerator : regulating_limit

          RegisteredGenerator --> RegulatingLimit : regulating_limit

      RegisteredGenerator : regulation_down_ramp_rate

          RegisteredGenerator --> ActivePowerChangeRate : regulation_down_ramp_rate

      RegisteredGenerator : regulation_flag

          RegisteredGenerator --> UnitRegulationKind : regulation_flag

      RegisteredGenerator : regulation_up_ramp_rate

          RegisteredGenerator --> ActivePowerChangeRate : regulation_up_ramp_rate

      RegisteredGenerator : reporting_group

          RegisteredGenerator --> ReportingGroup : reporting_group

      RegisteredGenerator : resource_adequacy_flag

          RegisteredGenerator --> YesNo : resource_adequacy_flag

      RegisteredGenerator : resource_ancillary_service_qualification

          RegisteredGenerator --> ResourceCertification : resource_ancillary_service_qualification

      RegisteredGenerator : resource_award_instruction

          RegisteredGenerator --> ResourceAwardInstruction : resource_award_instruction

      RegisteredGenerator : resource_capacity

          RegisteredGenerator --> ResourceCapacity : resource_capacity

      RegisteredGenerator : resource_certification

          RegisteredGenerator --> ResourceCertification : resource_certification

      RegisteredGenerator : resource_dispatch_results

          RegisteredGenerator --> ResourceDispatchResults : resource_dispatch_results

      RegisteredGenerator : resource_groups

          RegisteredGenerator --> ResourceGroup : resource_groups

      RegisteredGenerator : resource_load_following_inst

          RegisteredGenerator --> ResourceLoadFollowingInst : resource_load_following_inst

      RegisteredGenerator : resource_sub_type

      RegisteredGenerator : resource_verifiable_costs

          RegisteredGenerator --> ResourceVerifiableCosts : resource_verifiable_costs

      RegisteredGenerator : river_system

      RegisteredGenerator : rmnrflag

          RegisteredGenerator --> YesNo : rmnrflag

      RegisteredGenerator : rmrflag

          RegisteredGenerator --> FlagTypeRMR : rmrflag

      RegisteredGenerator : rmrheat_rate_curve

          RegisteredGenerator --> RMRHeatRateCurve : rmrheat_rate_curve

      RegisteredGenerator : rmrmanual_indicator

          RegisteredGenerator --> YesNo : rmrmanual_indicator

      RegisteredGenerator : rmroperator_input

          RegisteredGenerator --> RMROperatorInput : rmroperator_input

      RegisteredGenerator : rmrstart_up_cost_curve

          RegisteredGenerator --> RMRStartUpCostCurve : rmrstart_up_cost_curve

      RegisteredGenerator : rmrstart_up_energy_curve

          RegisteredGenerator --> RMRStartUpEnergyCurve : rmrstart_up_energy_curve

      RegisteredGenerator : rmrstart_up_fuel_curve

          RegisteredGenerator --> RMRStartUpFuelCurve : rmrstart_up_fuel_curve

      RegisteredGenerator : rmrstart_up_time_curve

          RegisteredGenerator --> RMRStartUpTimeCurve : rmrstart_up_time_curve

      RegisteredGenerator : rmtflag

          RegisteredGenerator --> YesNo : rmtflag

      RegisteredGenerator : rucaward_instruction

          RegisteredGenerator --> RUCAwardInstruction : rucaward_instruction

      RegisteredGenerator : smpmflag

          RegisteredGenerator --> YesNo : smpmflag

      RegisteredGenerator : spin_ramp_rate

          RegisteredGenerator --> ActivePowerChangeRate : spin_ramp_rate

      RegisteredGenerator : start_up_cost_basis

          RegisteredGenerator --> CostBasis : start_up_cost_basis

      RegisteredGenerator : start_up_cost_curves

          RegisteredGenerator --> StartUpCostCurve : start_up_cost_curves

      RegisteredGenerator : start_up_energy_curve

          RegisteredGenerator --> StartUpEnergyCurve : start_up_energy_curve

      RegisteredGenerator : start_up_fuel_curve

          RegisteredGenerator --> StartUpFuelCurve : start_up_fuel_curve

      RegisteredGenerator : start_up_time_curve

          RegisteredGenerator --> StartUpTimeCurve : start_up_time_curve

      RegisteredGenerator : sub_control_area

          RegisteredGenerator --> SubControlArea : sub_control_area

      RegisteredGenerator : substitution_resource_list

          RegisteredGenerator --> SubstitutionResourceList : substitution_resource_list

      RegisteredGenerator : sync_cond_capable

          RegisteredGenerator --> YesNo : sync_cond_capable

      RegisteredGenerator : targeting_cimdata_object

          RegisteredGenerator --> ChangeSetMember : targeting_cimdata_object

      RegisteredGenerator : time_series

          RegisteredGenerator --> TimeSeries : time_series

      RegisteredGenerator : trade

          RegisteredGenerator --> Trade : trade

      RegisteredGenerator : unit_initial_conditions

          RegisteredGenerator --> UnitInitialConditions : unit_initial_conditions

      RegisteredGenerator : unit_type

          RegisteredGenerator --> UnitType : unit_type

      RegisteredGenerator : use_limit_flag

          RegisteredGenerator --> YesNo : use_limit_flag

      RegisteredGenerator : variable_energy_resource

          RegisteredGenerator --> YesNo : variable_energy_resource

      RegisteredGenerator : verification_action

          RegisteredGenerator --> VerificationAction : verification_action

Inheritance

Slots

Name Cardinality and Range Description Inheritance
capacity_factor 0..1
PerCent
The ratio of actual energy produced by resource divided by the maximum potent... direct
cold_start_time 0..1
Float
Cold start time direct
combined_cycle_operating_mode 0..1
String
Combined Cycle operating mode direct
commericial_operation_date 0..1
date
direct
constrained_output_flag 0..1
YesNo
Constrained Output Generator (COG) Indicator (Yes/No), per Generating Resourc... direct
energy_down_ramp_rate 0..1
ActivePowerChangeRate
Response rate in MW per minute for ramping energy down direct
energy_up_ramp_rate 0..1
ActivePowerChangeRate
Response rate in MW per minute for ramping energy up direct
extreme_long_start 0..1
YesNo
Some long-start up time units may need to receive start up instruction before... direct
fuel_source 0..1
FuelSource
Values: Natural Gas Based Resource, Non Natural Gas Based Resource
direct
high_control_limit 0..1
ActivePower
High limit for secondary (AGC) control
direct
hot_int_time 0..1
Float
Hot-to-intermediate time (Seasonal)
direct
hot_start_time 0..1
Float
Hot start time direct
int_cold_time 0..1
Float
Intermediate-to-cold time (Seasonal)
direct
int_start_time 0..1
Float
Intermediate start time direct
load_following_down_mss 0..1
YesNo
Certifies resources for use in MSS Load Following Down
direct
load_following_up_mss 0..1
YesNo
Certifies resources for use in MSS Load Following Up
direct
low_control_limit 0..1
ActivePower
Low limit for secondary (AGC) control
direct
max_dependable_cap 0..1
ActivePower
Maximum Dependable Capacity (MNDC) direct
maximum_allowable_spinning_reserve 0..1
ActivePower
Maximum allowable spinning reserve direct
maximum_operating_limit 0..1
ActivePower
This is the maximum operating MW limit the dispatcher can enter for this unit direct
max_min_load_cost 0..1
CostRate
The registered maximum Minimum Load Cost of a Generating Resource registered ... direct
max_pumping_level 0..1
ActivePower
max pumping level of a hydro pump unit
direct
max_shutdown_time 0..1
date
Maximum time this device can be shut down direct
max_start_ups_per_day 0..1
Integer
maximum start ups per day
direct
max_weekly_energy 0..1
Float
Maximum weekly Energy (Seasonal)
direct
max_weekly_starts 0..1
Integer
Maximum weekly starts (seasonal parameter)
direct
minimum_load_cost_basis 0..1
CostBasis
The cost basis for minimum load direct
minimum_load_fuel_cost 0..1
CostPerHeatUnit
The cost for the fuel required to get a Generating Resource to operate at the... direct
minimum_operating_limit 0..1
ActivePower
This is the minimum operating MW limit the dispatcher can enter for this unit direct
min_load_cost 0..1
CostRate
minimum load cost direct
must_offer_ra 0..1
YesNo
Flag to indicate that this unit is a resource adequacy resource and must offe... direct
nameplate_capacity 0..1
ActivePower
MW value stated on the nameplate of the Generator -- the value it potentially... direct
operating_maintenance_cost 0..1
CostPerEnergyUnit
The portion of the Operating Cost of a Generating Resource that is not relate... direct
pumping_cost 0..1
CostRate
direct
pumping_factor 0..1
Float
Pumping factor for pump storage units, conversion factor between generating a... direct
pump_min_down_time 0..1
Float
The minimum down time for the pump in a pump storage unit direct
pump_min_up_time 0..1
Float
The minimum up time aspect for the pump in a pump storage unit
direct
pump_shutdown_cost 0..1
Float
The cost to shutdown a pump during the pump aspect of a pump storage unit direct
pump_shutdown_time 0..1
Integer
The shutdown time (minutes) of the pump aspect of a pump storage unit direct
quick_start_flag 0..1
YesNo
Quick start flag (Yes/No) direct
ramp_curve_type 0..1
RampCurveType
Ramp curve type direct
regulation_down_ramp_rate 0..1
ActivePowerChangeRate
Regulation down response rate in MW per minute direct
regulation_flag 0..1
UnitRegulationKind
Specifies if the unit is regulating or not regulating or expected to be regul... direct
regulation_up_ramp_rate 0..1
ActivePowerChangeRate
Regulation up response rate in MW per minute direct
resource_sub_type 0..1
String
Unit sub type used by Settlements or scheduling application direct
river_system 0..1
String
River System the Resource is tied to direct
rmnrflag 0..1
YesNo
Reliability must not run (RMNR) flag: indicated whether the RMR unit is set a... direct
rmrflag 0..1
FlagTypeRMR
Reliability must run (RMR) flag: indicates whether the unit is RMR; Indicates... direct
rmrmanual_indicator 0..1
YesNo
Indicates the RMR Manual pre-determination status [Y/N]
direct
rmtflag 0..1
YesNo
Reliability must take (RMT) flag (Yes/No): indicates whether the unit is RMT
direct
spin_ramp_rate 0..1
ActivePowerChangeRate
Response rate in MW per minute for spinning reserve direct
start_up_cost_basis 0..1
CostBasis
The cost basis for start up direct
sync_cond_capable 0..1
YesNo
Is the Resource Synchronous Condenser capable Resource?
direct
unit_type 0..1
UnitType
Generating unit type: Combined Cycle, Gas Turbine, Hydro Turbine, Other, Phot... direct
use_limit_flag 0..1
YesNo
Use limit flag: indicates if the use-limited resource is fully scheduled (or ... direct
variable_energy_resource 0..1
YesNo
Provides an indication that this resource is intending to participate in an i... direct
trade 0..*
Trade
direct
mkt_heat_rate_curve 0..1
MktHeatRateCurve
direct
rmrstart_up_energy_curve 0..1
RMRStartUpEnergyCurve
direct
rmrstart_up_time_curve 0..1
RMRStartUpTimeCurve
direct
start_up_energy_curve 0..1
StartUpEnergyCurve
direct
start_up_time_curve 0..1
StartUpTimeCurve
direct
regulating_limit 0..1
RegulatingLimit
direct
start_up_fuel_curve 0..1
StartUpFuelCurve
direct
generating_bids 0..*
GeneratingBid
direct
rmrstart_up_cost_curve 0..1
RMRStartUpCostCurve
direct
rmrstart_up_fuel_curve 0..1
RMRStartUpFuelCurve
direct
rmrheat_rate_curve 0..1
RMRHeatRateCurve
direct
fuel_region 0..1
FuelRegion
direct
local_reliability_area 0..1
LocalReliabilityArea
direct
start_up_cost_curves 0..*
StartUpCostCurve
direct
energy_price_index 1..1
EnergyPriceIndex
direct
auxillary_object 0..*
AuxiliaryObject
direct
fuel_cost_curve 0..1
FuelCostCurve
direct
unit_initial_conditions 0..*
UnitInitialConditions
direct
acaflag 0..1
YesNo
Indication that this resource is associated with an Adjacent Control Area RegisteredResource
asspoptimization_flag 0..1
YesNo
Indication that the resource participates in the optimization process by defa... RegisteredResource
commercial_op_date 0..1
date
Resource Commercial Operation Date RegisteredResource
contingency_avail_flag 0..1
YesNo
Contingent operating reserve availiability (Yes/No) RegisteredResource
dispatchable 0..1
Boolean
Dispatchable: indicates whether the resource is dispatchable RegisteredResource
ecaflag 0..1
YesNo
Indication that this resource is associated with an Embedded Control area RegisteredResource
flexible_offer_flag 0..1
YesNo
Flexible offer flag (Y/N) RegisteredResource
hourly_predispatch 0..1
YesNo
Indicates need to dispatch before the start of the operating hour RegisteredResource
is_aggregated_res 0..1
YesNo
A flag to indicate if a resource is an aggregated resource RegisteredResource
last_modified 0..1
date
Indication of the last time this item was modified/versioned RegisteredResource
lmpmflag 0..1
YesNo
LMPM flag: indicates whether the resource is subject to the LMPM test (Yes/No... RegisteredResource
market_participation_flag 0..1
YesNo
Market Participation flag: indicates whether the resource participate in the ... RegisteredResource
max_base_self_sched_qty 0..1
Float
Maximum base self schedule quantity RegisteredResource
max_on_time 0..1
Float
Maximum on time after start up RegisteredResource
min_dispatch_time 0..1
Hours
Minimum number of consecutive hours a resource shall be dispatched if bid is ... RegisteredResource
min_off_time 0..1
Float
Minimum off time after shut down RegisteredResource
min_on_time 0..1
Float
Minimum on time after start up RegisteredResource
must_offer_flag 0..1
YesNo
Must offer flag: indicates whether the unit is subject to the must offer prov... RegisteredResource
non_market 0..1
YesNo
Flag to indicate that the Resource is not participating in the Market Operati... RegisteredResource
point_of_delivery_flag 0..1
YesNo
Indication that the registered resource is a Point of Delivery (YES) resource... RegisteredResource
price_set_flag_da 0..1
YesNo
Price setting flag: indicates whether a resource is capable of setting the Ma... RegisteredResource
price_set_flag_rt 0..1
YesNo
Price setting flag: indicates whether a resource is capable of setting the Ma... RegisteredResource
registration_status 0..1
ResourceRegistrationStatus
Registration Status of resource - Active, Mothballed, Planned, or Decommissio... RegisteredResource
resource_adequacy_flag 0..1
YesNo
Indication that this resource participates in the resource adequacy function RegisteredResource
smpmflag 0..1
YesNo
SMPM flag: indicates whether the resource is subject to the SMPM test (Yes/No... RegisteredResource
dop_instruction 0..*
DopInstruction
RegisteredResource
resource_groups 0..*
ResourceGroup
RegisteredResource
resource_certification 0..*
ResourceCertification
RegisteredResource
mkt_connectivity_node 0..1
MktConnectivityNode
RegisteredResource
inter_tie 0..*
SchedulingPoint
RegisteredResource
former_reference 0..*
FormerReference
RegisteredResource
intermittent_resource_eligibility 0..*
IntermittentResourceEligibility
RegisteredResource
resource_capacity 0..*
ResourceCapacity
RegisteredResource
reason 0..*
Reason
RegisteredResource
expected_energy_values 0..*
ExpectedEnergyValues
RegisteredResource
resource_ancillary_service_qualification 0..*
ResourceCertification
RegisteredResources are qualified for resource ancillary service types (which... RegisteredResource
resource_load_following_inst 0..*
ResourceLoadFollowingInst
RegisteredResource
load_following_inst 0..*
LoadFollowingInst
RegisteredResource
allocation_result_values 0..*
AllocationResultValues
RegisteredResource
rucaward_instruction 0..*
RUCAwardInstruction
RegisteredResource
mpmresource_status 0..*
MPMResourceStatus
RegisteredResource
commitments 0..*
Commitments
RegisteredResource
market_participant 0..1
MarketParticipant
RegisteredResource
sub_control_area 0..*
SubControlArea
RegisteredResource
adjacent_caset 0..1
AdjacentCASet
RegisteredResource
substitution_resource_list 0..*
SubstitutionResourceList
RegisteredResource
resource_dispatch_results 0..*
ResourceDispatchResults
RegisteredResource
rmroperator_input 0..*
RMROperatorInput
RegisteredResource
org_res_ownership 0..*
OrgResOwnership
RegisteredResource
contract_distribution_factor 0..*
ContractDistributionFactor
RegisteredResource
ramp_rate_curve 0..*
RampRateCurve
RegisteredResource
time_series 0..*
TimeSeries
RegisteredResource
dispatch_inst_reply 0..*
DispatchInstReply
RegisteredResource
aggregate_node 0..1
AggregateNode
An AggregateNode may be associated with up to many RegisteredResources RegisteredResource
forbidden_region 0..*
ForbiddenRegion
RegisteredResource
dot_instruction 0..*
DotInstruction
RegisteredResource
energy_markets 0..*
EnergyMarket
RegisteredResource
domain 0..*
Domain
RegisteredResource
instructions 0..*
Instructions
RegisteredResource
host_control_area 0..1
HostControlArea
RegisteredResource
pnode 0..1
Pnode
A registered resource injects power at one or more connectivity nodes related... RegisteredResource
ex_post_resource_results 0..*
ExPostResourceResults
RegisteredResource
resource_award_instruction 0..*
ResourceAwardInstruction
RegisteredResource
mpmtest_threshold 0..*
MPMTestThreshold
RegisteredResource
load_following_operator_input 0..*
LoadFollowingOperatorInput
RegisteredResource
control_area_designation 0..*
ControlAreaDesignation
RegisteredResource
market_object_status 0..*
MarketObjectStatus
RegisteredResource
default_bid 0..1
DefaultBid
RegisteredResource
resource_verifiable_costs 0..1
ResourceVerifiableCosts
RegisteredResource
controls 0..*
Control
The controller outputs used to actually govern a regulating device, e PowerSystemResource
measurements 0..*
Measurement
The measurements associated with this power system resource PowerSystemResource
psrtype 0..1
PSRType
Custom classification for this power system resource PowerSystemResource
configuration_event 0..*
ConfigurationEvent
All configuration events created for this Power System resource PowerSystemResource
reporting_group 0..*
ReportingGroup
Reporting groups to which this power system resource belongs PowerSystemResource
operating_share 0..*
OperatingShare
The operating shares of this power system resource PowerSystemResource
asset_datasheet 0..1
AssetInfo
Datasheet information for this power system resource PowerSystemResource
verification_action 0..*
VerificationAction
The verification action that is performed on the power system resource PowerSystemResource
clearances 0..*
ClearanceDocument
All clearances applicable to this power system resource PowerSystemResource
generic_action 0..*
GenericAction
The generic action that is performed on the power system resource PowerSystemResource
psrevents 0..*
PSREvent
All events associated with this power system resource PowerSystemResource
assets 0..*
Asset
All assets represented by this power system resource PowerSystemResource
location 0..1
Location
Location of this power system resource PowerSystemResource
operational_tags 0..*
OperationalTag
All operational tags placed on this power system resource PowerSystemResource
alias_name 0..1
String
The aliasName is free text human readable name of the object alternative to I... IdentifiedObject
description 0..1
String
The description is a free human readable text describing or naming the object IdentifiedObject
m_rid 0..1
String
Master resource identifier issued by a model authority IdentifiedObject
diagram_objects 0..*
DiagramObject
The diagram objects that are associated with the domain object IdentifiedObject
instance_set 1..1
InstanceSet
Dataset containing the data objects IdentifiedObject
names 0..*
Name
All names of this identified object IdentifiedObject
properties_cimdata_object 0..1
ChangeSetMember
The single CIM data object in the appropriate dataset context IdentifiedObject
targeting_cimdata_object 0..*
ChangeSetMember
Data objects registered IdentifiedObject

Usages

used by used in type used
Trade registered_generator range RegisteredGenerator
FuelRegion registered_generator range RegisteredGenerator
LocalReliabilityArea registered_generator range RegisteredGenerator
StartUpCostCurve registered_generators range RegisteredGenerator
GeneratingBid registered_generator range RegisteredGenerator
StartUpTimeCurve registered_generator range RegisteredGenerator
AuxiliaryObject registered_generator range RegisteredGenerator
EnergyPriceIndex registered_generator range RegisteredGenerator
FuelCostCurve registered_generator range RegisteredGenerator
UnitInitialConditions generating_unit range RegisteredGenerator
MktHeatRateCurve registered_generator range RegisteredGenerator
RMRStartUpEnergyCurve registered_generator range RegisteredGenerator
RMRStartUpTimeCurve registered_generator range RegisteredGenerator
StartUpEnergyCurve registered_generator range RegisteredGenerator
RegulatingLimit registered_generator range RegisteredGenerator
StartUpFuelCurve registered_generator range RegisteredGenerator
RMRStartUpCostCurve registered_generator range RegisteredGenerator
RMRStartUpFuelCurve registered_generator range RegisteredGenerator
RMRHeatRateCurve registered_generator range RegisteredGenerator
AuxiliaryValues registered_generator range RegisteredGenerator

Identifier and Mapping Information

Schema Source

  • from schema: https://cim.ucaiug.io/ns#TC57CIM

Mappings

Mapping Type Mapped Value
self cim:RegisteredGenerator
native cim:RegisteredGenerator

LinkML Source

Direct

name: RegisteredGenerator
description: Model of a generator  that is registered to participate in the market.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
is_a: RegisteredResource
attributes:
  capacity_factor:
    name: capacity_factor
    description: The ratio of actual energy produced by resource divided by the maximum
      potential energy if the resource is fully utilized. As an example, wind farms.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.capacityFactor
    multivalued: false
    domain_of:
    - RegisteredGenerator
    range: PerCent
    required: false
  cold_start_time:
    name: cold_start_time
    description: "Cold start time.\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.coldStartTime
    multivalued: false
    domain_of:
    - RegisteredGenerator
    range: float
    required: false
  combined_cycle_operating_mode:
    name: combined_cycle_operating_mode
    description: Combined Cycle operating mode.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.combinedCycleOperatingMode
    multivalued: false
    domain_of:
    - RegisteredGenerator
    range: string
    required: false
  commericial_operation_date:
    name: commericial_operation_date
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.commericialOperationDate
    multivalued: false
    domain_of:
    - RegisteredGenerator
    range: date
    required: false
  constrained_output_flag:
    name: constrained_output_flag
    description: "Constrained Output Generator (COG) Indicator (Yes/No), per Generating\
      \ Resource\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.constrainedOutputFlag
    multivalued: false
    domain_of:
    - RegisteredGenerator
    range: YesNo
    required: false
  energy_down_ramp_rate:
    name: energy_down_ramp_rate
    description: Response rate in MW per minute for ramping energy down.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.energyDownRampRate
    multivalued: false
    domain_of:
    - RegisteredGenerator
    range: ActivePowerChangeRate
    required: false
  energy_up_ramp_rate:
    name: energy_up_ramp_rate
    description: Response rate in MW per minute for ramping energy up.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.energyUpRampRate
    multivalued: false
    domain_of:
    - RegisteredGenerator
    range: ActivePowerChangeRate
    required: false
  extreme_long_start:
    name: extreme_long_start
    description: Some long-start up time units may need to receive start up instruction
      before DA market results are available.  Long-Start resources may be either
      physical resources within the control with start-up times greater than 18 hours
      or the long-start contractual inter-tie commitment that shall be completed by
      6 am one-day ahead.  Therefore, there is a need for a process to determine the
      commitment of such resources before the DA market.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.extremeLongStart
    multivalued: false
    domain_of:
    - RegisteredGenerator
    range: YesNo
    required: false
  fuel_source:
    name: fuel_source
    description: "Values: Natural Gas Based Resource, Non Natural Gas Based Resource\r\
      \n\"NG\" - Natural-Gas-Based Resource - a Resource that is powered by Natural\
      \ Gas\r\n\"NNG\" - Non-Natural-Gas-Based Resource - a Resouce that is powered\
      \ by some other fuel than Natural Gas\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.fuelSource
    multivalued: false
    domain_of:
    - RegisteredGenerator
    range: FuelSource
    required: false
  high_control_limit:
    name: high_control_limit
    description: "High limit for secondary (AGC) control\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.highControlLimit
    multivalued: false
    domain_of:
    - RegisteredGenerator
    - GeneratingUnit
    range: ActivePower
    required: false
  hot_int_time:
    name: hot_int_time
    description: "Hot-to-intermediate time (Seasonal)\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.hotIntTime
    multivalued: false
    domain_of:
    - RegisteredGenerator
    range: float
    required: false
  hot_start_time:
    name: hot_start_time
    description: "Hot start time.\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.hotStartTime
    multivalued: false
    domain_of:
    - RegisteredGenerator
    range: float
    required: false
  int_cold_time:
    name: int_cold_time
    description: "Intermediate-to-cold time (Seasonal)\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.intColdTime
    multivalued: false
    domain_of:
    - RegisteredGenerator
    range: float
    required: false
  int_start_time:
    name: int_start_time
    description: "Intermediate start time.\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.intStartTime
    multivalued: false
    domain_of:
    - RegisteredGenerator
    range: float
    required: false
  load_following_down_mss:
    name: load_following_down_mss
    description: "Certifies resources for use in MSS Load Following Down\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.loadFollowingDownMSS
    multivalued: false
    domain_of:
    - RegisteredGenerator
    range: YesNo
    required: false
  load_following_up_mss:
    name: load_following_up_mss
    description: "Certifies resources for use in MSS Load Following Up\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.loadFollowingUpMSS
    multivalued: false
    domain_of:
    - RegisteredGenerator
    range: YesNo
    required: false
  low_control_limit:
    name: low_control_limit
    description: "Low limit for secondary (AGC) control\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.lowControlLImit
    multivalued: false
    domain_of:
    - RegisteredGenerator
    - GeneratingUnit
    range: ActivePower
    required: false
  max_dependable_cap:
    name: max_dependable_cap
    description: Maximum Dependable Capacity (MNDC). Maximun Net Dependable Capacity
      is used in association with an RMR contract.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.maxDependableCap
    multivalued: false
    domain_of:
    - RegisteredGenerator
    range: ActivePower
    required: false
  maximum_allowable_spinning_reserve:
    name: maximum_allowable_spinning_reserve
    description: "Maximum allowable spinning reserve. Spinning reserve will never\
      \ be considered greater than this value regardless of the current operating\
      \ point.\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.maximumAllowableSpinningReserve
    multivalued: false
    domain_of:
    - RegisteredGenerator
    - GeneratingUnit
    range: ActivePower
    required: false
  maximum_operating_limit:
    name: maximum_operating_limit
    description: This is the maximum operating MW limit the dispatcher can enter for
      this unit
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.maximumOperatingLimit
    multivalued: false
    domain_of:
    - RegisteredGenerator
    range: ActivePower
    required: false
  max_min_load_cost:
    name: max_min_load_cost
    description: "The registered maximum Minimum Load Cost of a Generating Resource\
      \ registered with a Cost Basis of \"Bid Cost\".\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.maxMinLoadCost
    multivalued: false
    domain_of:
    - RegisteredGenerator
    range: CostRate
    required: false
  max_pumping_level:
    name: max_pumping_level
    description: "max pumping level of a hydro pump unit\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.maxPumpingLevel
    multivalued: false
    domain_of:
    - RegisteredGenerator
    range: ActivePower
    required: false
  max_shutdown_time:
    name: max_shutdown_time
    description: "Maximum time this device can be shut down.\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.maxShutdownTime
    multivalued: false
    domain_of:
    - RegisteredGenerator
    range: date
    required: false
  max_start_ups_per_day:
    name: max_start_ups_per_day
    description: "maximum start ups per day\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.maxStartUpsPerDay
    multivalued: false
    domain_of:
    - RegisteredGenerator
    range: integer
    required: false
  max_weekly_energy:
    name: max_weekly_energy
    description: "Maximum weekly Energy (Seasonal)\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.maxWeeklyEnergy
    multivalued: false
    domain_of:
    - RegisteredGenerator
    range: float
    required: false
  max_weekly_starts:
    name: max_weekly_starts
    description: "Maximum weekly starts (seasonal parameter)\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.maxWeeklyStarts
    multivalued: false
    domain_of:
    - RegisteredGenerator
    range: integer
    required: false
  minimum_load_cost_basis:
    name: minimum_load_cost_basis
    description: The cost basis for minimum load.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.minimumLoadCostBasis
    multivalued: false
    domain_of:
    - RegisteredGenerator
    range: CostBasis
    required: false
  minimum_load_fuel_cost:
    name: minimum_load_fuel_cost
    description: "The cost for the fuel required to get a Generating Resource to operate\
      \ at the minimum load level\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.minimumLoadFuelCost
    multivalued: false
    domain_of:
    - RegisteredGenerator
    range: CostPerHeatUnit
    required: false
  minimum_operating_limit:
    name: minimum_operating_limit
    description: This is the minimum operating MW limit the dispatcher can enter for
      this unit.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.minimumOperatingLimit
    multivalued: false
    domain_of:
    - RegisteredGenerator
    range: ActivePower
    required: false
  min_load_cost:
    name: min_load_cost
    description: "minimum load cost. Value is (currency/hr)\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.minLoadCost
    multivalued: false
    domain_of:
    - RegisteredGenerator
    - DefaultBid
    range: CostRate
    required: false
  must_offer_ra:
    name: must_offer_ra
    description: "Flag to indicate that this unit is a resource adequacy resource\
      \ and must offer.\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.mustOfferRA
    multivalued: false
    domain_of:
    - RegisteredGenerator
    range: YesNo
    required: false
  nameplate_capacity:
    name: nameplate_capacity
    description: "MW value stated on the nameplate of the Generator -- the value it\
      \ potentially could provide.\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.nameplateCapacity
    multivalued: false
    domain_of:
    - RegisteredGenerator
    range: ActivePower
    required: false
  operating_maintenance_cost:
    name: operating_maintenance_cost
    description: "The portion of the Operating Cost of a Generating Resource that\
      \ is not related to fuel cost.\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.operatingMaintenanceCost
    multivalued: false
    domain_of:
    - RegisteredGenerator
    range: CostPerEnergyUnit
    required: false
  pumping_cost:
    name: pumping_cost
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.pumpingCost
    multivalued: false
    domain_of:
    - RegisteredGenerator
    range: CostRate
    required: false
  pumping_factor:
    name: pumping_factor
    description: "Pumping factor for pump storage units, conversion factor between\
      \ generating and pumping.\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.pumpingFactor
    multivalued: false
    domain_of:
    - RegisteredGenerator
    range: float
    required: false
  pump_min_down_time:
    name: pump_min_down_time
    description: "The minimum down time for the pump in a pump storage unit.\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.pumpMinDownTime
    multivalued: false
    domain_of:
    - RegisteredGenerator
    range: float
    required: false
  pump_min_up_time:
    name: pump_min_up_time
    description: "The minimum up time aspect for the pump in a pump storage unit\r\
      \n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.pumpMinUpTime
    multivalued: false
    domain_of:
    - RegisteredGenerator
    range: float
    required: false
  pump_shutdown_cost:
    name: pump_shutdown_cost
    description: "The cost to shutdown a pump during the pump aspect of a pump storage\
      \ unit.\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.pumpShutdownCost
    multivalued: false
    domain_of:
    - RegisteredGenerator
    range: float
    required: false
  pump_shutdown_time:
    name: pump_shutdown_time
    description: "The shutdown time (minutes) of the pump aspect of a pump storage\
      \ unit.\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.pumpShutdownTime
    multivalued: false
    domain_of:
    - RegisteredGenerator
    range: integer
    required: false
  quick_start_flag:
    name: quick_start_flag
    description: Quick start flag (Yes/No). Identifies the registered generator as
      a quick start unit. A quick start unit is a unit that has the ability to be
      available for load within a 30 minute period.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.quickStartFlag
    multivalued: false
    domain_of:
    - RegisteredGenerator
    range: YesNo
    required: false
  ramp_curve_type:
    name: ramp_curve_type
    description: Ramp curve type. Identifies the type of curve which may be a fixed,
      static or dynamic.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.rampCurveType
    multivalued: false
    domain_of:
    - RegisteredGenerator
    - GeneratingBid
    range: RampCurveType
    required: false
  regulation_down_ramp_rate:
    name: regulation_down_ramp_rate
    description: Regulation down response rate in MW per minute
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.regulationDownRampRate
    multivalued: false
    domain_of:
    - RegisteredGenerator
    range: ActivePowerChangeRate
    required: false
  regulation_flag:
    name: regulation_flag
    description: Specifies if the unit is regulating or not regulating or expected
      to be regulating but is not.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.regulationFlag
    multivalued: false
    domain_of:
    - RegisteredGenerator
    range: UnitRegulationKind
    required: false
  regulation_up_ramp_rate:
    name: regulation_up_ramp_rate
    description: Regulation up response rate in MW per minute.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.regulationUpRampRate
    multivalued: false
    domain_of:
    - RegisteredGenerator
    range: ActivePowerChangeRate
    required: false
  resource_sub_type:
    name: resource_sub_type
    description: Unit sub type used by Settlements or scheduling application. Application
      use of the unit sub type may define the necessary types as applicable.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.resourceSubType
    multivalued: false
    domain_of:
    - RegisteredGenerator
    range: string
    required: false
  river_system:
    name: river_system
    description: "River System the Resource is tied to.\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.riverSystem
    multivalued: false
    domain_of:
    - RegisteredGenerator
    range: string
    required: false
  rmnrflag:
    name: rmnrflag
    description: "Reliability must not run (RMNR) flag: indicated whether the RMR\
      \ unit is set as an RMNR in the current market\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.RMNRFlag
    multivalued: false
    domain_of:
    - RegisteredGenerator
    range: YesNo
    required: false
  rmrflag:
    name: rmrflag
    description: "Reliability must run (RMR) flag: indicates whether the unit is RMR;\
      \ Indicates whether the unit is RMR:\r\nN' - not an RMR unit\r\n'1' - RMR Condition\
      \ 1 unit\r\n'2' - RMR Condition 2 unit\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.RMRFlag
    multivalued: false
    domain_of:
    - RegisteredGenerator
    range: FlagTypeRMR
    required: false
  rmrmanual_indicator:
    name: rmrmanual_indicator
    description: "Indicates the RMR Manual pre-determination status [Y/N]\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.RMRManualIndicator
    multivalued: false
    domain_of:
    - RegisteredGenerator
    range: YesNo
    required: false
  rmtflag:
    name: rmtflag
    description: "Reliability must take (RMT) flag (Yes/No): indicates whether the\
      \ unit is RMT\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.RMTFlag
    multivalued: false
    domain_of:
    - RegisteredGenerator
    range: YesNo
    required: false
  spin_ramp_rate:
    name: spin_ramp_rate
    description: Response rate in MW per minute for spinning reserve.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.spinRampRate
    multivalued: false
    domain_of:
    - RegisteredGenerator
    range: ActivePowerChangeRate
    required: false
  start_up_cost_basis:
    name: start_up_cost_basis
    description: The cost basis for start up.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.startUpCostBasis
    multivalued: false
    domain_of:
    - RegisteredGenerator
    range: CostBasis
    required: false
  sync_cond_capable:
    name: sync_cond_capable
    description: "Is the Resource Synchronous Condenser capable Resource? \r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.syncCondCapable
    multivalued: false
    domain_of:
    - RegisteredGenerator
    range: YesNo
    required: false
  unit_type:
    name: unit_type
    description: "Generating unit type: Combined Cycle, Gas Turbine, Hydro Turbine,\
      \ Other, Photovoltaic, Hydro Pump-Turbine, Reciprocating Engine, Steam Turbine,\
      \ Synchronous Condenser, Wind Turbine\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.unitType
    multivalued: false
    domain_of:
    - RegisteredGenerator
    range: UnitType
    required: false
  use_limit_flag:
    name: use_limit_flag
    description: "Use limit flag: indicates if the use-limited resource is fully scheduled\
      \ (or has some slack for real-time dispatch) (Y/N)\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.useLimitFlag
    multivalued: false
    domain_of:
    - RegisteredGenerator
    range: YesNo
    required: false
  variable_energy_resource:
    name: variable_energy_resource
    description: Provides an indication that this resource is intending to participate
      in an intermittent resource program.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.variableEnergyResource
    multivalued: false
    domain_of:
    - RegisteredGenerator
    range: YesNo
    required: false
  trade:
    name: trade
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:RegisteredGenerator.Trade
    multivalued: true
    domain_of:
    - Pnode
    - RegisteredGenerator
    - ActionRequest
    - TradeProduct
    - TradeError
    range: Trade
    required: false
  mkt_heat_rate_curve:
    name: mkt_heat_rate_curve
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.MktHeatRateCurve
    multivalued: false
    domain_of:
    - RegisteredGenerator
    - ResourceVerifiableCosts
    range: MktHeatRateCurve
    required: false
  rmrstart_up_energy_curve:
    name: rmrstart_up_energy_curve
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.RMRStartUpEnergyCurve
    multivalued: false
    domain_of:
    - RegisteredGenerator
    range: RMRStartUpEnergyCurve
    required: false
  rmrstart_up_time_curve:
    name: rmrstart_up_time_curve
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.RMRStartUpTimeCurve
    multivalued: false
    domain_of:
    - RegisteredGenerator
    range: RMRStartUpTimeCurve
    required: false
  start_up_energy_curve:
    name: start_up_energy_curve
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.StartUpEnergyCurve
    multivalued: false
    domain_of:
    - RegisteredGenerator
    range: StartUpEnergyCurve
    required: false
  start_up_time_curve:
    name: start_up_time_curve
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.StartUpTimeCurve
    multivalued: false
    domain_of:
    - RegisteredGenerator
    - GeneratingBid
    range: StartUpTimeCurve
    required: false
  regulating_limit:
    name: regulating_limit
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.RegulatingLimit
    multivalued: false
    domain_of:
    - RegisteredGenerator
    range: RegulatingLimit
    required: false
  start_up_fuel_curve:
    name: start_up_fuel_curve
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.StartUpFuelCurve
    multivalued: false
    domain_of:
    - RegisteredGenerator
    range: StartUpFuelCurve
    required: false
  generating_bids:
    name: generating_bids
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.GeneratingBids
    multivalued: true
    domain_of:
    - RegisteredGenerator
    - NotificationTimeCurve
    - BidSet
    range: GeneratingBid
    required: false
  rmrstart_up_cost_curve:
    name: rmrstart_up_cost_curve
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.RMRStartUpCostCurve
    multivalued: false
    domain_of:
    - RegisteredGenerator
    range: RMRStartUpCostCurve
    required: false
  rmrstart_up_fuel_curve:
    name: rmrstart_up_fuel_curve
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.RMRStartUpFuelCurve
    multivalued: false
    domain_of:
    - RegisteredGenerator
    range: RMRStartUpFuelCurve
    required: false
  rmrheat_rate_curve:
    name: rmrheat_rate_curve
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.RMRHeatRateCurve
    multivalued: false
    domain_of:
    - RegisteredGenerator
    range: RMRHeatRateCurve
    required: false
  fuel_region:
    name: fuel_region
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:RegisteredGenerator.FuelRegion
    multivalued: false
    domain_of:
    - RTO
    - RegisteredGenerator
    - GasPrice
    - OilPrice
    range: FuelRegion
    required: false
  local_reliability_area:
    name: local_reliability_area
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:RegisteredGenerator.LocalReliabilityArea
    multivalued: false
    domain_of:
    - RTO
    - RegisteredGenerator
    range: LocalReliabilityArea
    required: false
  start_up_cost_curves:
    name: start_up_cost_curves
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.StartUpCostCurves
    multivalued: true
    domain_of:
    - RegisteredGenerator
    range: StartUpCostCurve
    required: false
  energy_price_index:
    name: energy_price_index
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.EnergyPriceIndex
    multivalued: false
    domain_of:
    - RegisteredGenerator
    - EnergyPriceIndex
    range: EnergyPriceIndex
    required: true
  auxillary_object:
    name: auxillary_object
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.AuxillaryObject
    multivalued: true
    domain_of:
    - RegisteredGenerator
    - RegisteredLoad
    range: AuxiliaryObject
    required: false
  fuel_cost_curve:
    name: fuel_cost_curve
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.FuelCostCurve
    multivalued: false
    domain_of:
    - RegisteredGenerator
    range: FuelCostCurve
    required: false
  unit_initial_conditions:
    name: unit_initial_conditions
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.UnitInitialConditions
    multivalued: true
    domain_of:
    - RegisteredGenerator
    range: UnitInitialConditions
    required: false
class_uri: cim:RegisteredGenerator

Induced

name: RegisteredGenerator
description: Model of a generator  that is registered to participate in the market.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
is_a: RegisteredResource
attributes:
  capacity_factor:
    name: capacity_factor
    description: The ratio of actual energy produced by resource divided by the maximum
      potential energy if the resource is fully utilized. As an example, wind farms.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.capacityFactor
    multivalued: false
    alias: capacity_factor
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    range: PerCent
    required: false
  cold_start_time:
    name: cold_start_time
    description: "Cold start time.\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.coldStartTime
    multivalued: false
    alias: cold_start_time
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    range: float
    required: false
  combined_cycle_operating_mode:
    name: combined_cycle_operating_mode
    description: Combined Cycle operating mode.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.combinedCycleOperatingMode
    multivalued: false
    alias: combined_cycle_operating_mode
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    range: string
    required: false
  commericial_operation_date:
    name: commericial_operation_date
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.commericialOperationDate
    multivalued: false
    alias: commericial_operation_date
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    range: date
    required: false
  constrained_output_flag:
    name: constrained_output_flag
    description: "Constrained Output Generator (COG) Indicator (Yes/No), per Generating\
      \ Resource\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.constrainedOutputFlag
    multivalued: false
    alias: constrained_output_flag
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    range: YesNo
    required: false
  energy_down_ramp_rate:
    name: energy_down_ramp_rate
    description: Response rate in MW per minute for ramping energy down.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.energyDownRampRate
    multivalued: false
    alias: energy_down_ramp_rate
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    range: ActivePowerChangeRate
    required: false
  energy_up_ramp_rate:
    name: energy_up_ramp_rate
    description: Response rate in MW per minute for ramping energy up.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.energyUpRampRate
    multivalued: false
    alias: energy_up_ramp_rate
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    range: ActivePowerChangeRate
    required: false
  extreme_long_start:
    name: extreme_long_start
    description: Some long-start up time units may need to receive start up instruction
      before DA market results are available.  Long-Start resources may be either
      physical resources within the control with start-up times greater than 18 hours
      or the long-start contractual inter-tie commitment that shall be completed by
      6 am one-day ahead.  Therefore, there is a need for a process to determine the
      commitment of such resources before the DA market.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.extremeLongStart
    multivalued: false
    alias: extreme_long_start
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    range: YesNo
    required: false
  fuel_source:
    name: fuel_source
    description: "Values: Natural Gas Based Resource, Non Natural Gas Based Resource\r\
      \n\"NG\" - Natural-Gas-Based Resource - a Resource that is powered by Natural\
      \ Gas\r\n\"NNG\" - Non-Natural-Gas-Based Resource - a Resouce that is powered\
      \ by some other fuel than Natural Gas\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.fuelSource
    multivalued: false
    alias: fuel_source
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    range: FuelSource
    required: false
  high_control_limit:
    name: high_control_limit
    description: "High limit for secondary (AGC) control\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.highControlLimit
    multivalued: false
    alias: high_control_limit
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    - GeneratingUnit
    range: ActivePower
    required: false
  hot_int_time:
    name: hot_int_time
    description: "Hot-to-intermediate time (Seasonal)\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.hotIntTime
    multivalued: false
    alias: hot_int_time
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    range: float
    required: false
  hot_start_time:
    name: hot_start_time
    description: "Hot start time.\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.hotStartTime
    multivalued: false
    alias: hot_start_time
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    range: float
    required: false
  int_cold_time:
    name: int_cold_time
    description: "Intermediate-to-cold time (Seasonal)\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.intColdTime
    multivalued: false
    alias: int_cold_time
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    range: float
    required: false
  int_start_time:
    name: int_start_time
    description: "Intermediate start time.\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.intStartTime
    multivalued: false
    alias: int_start_time
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    range: float
    required: false
  load_following_down_mss:
    name: load_following_down_mss
    description: "Certifies resources for use in MSS Load Following Down\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.loadFollowingDownMSS
    multivalued: false
    alias: load_following_down_mss
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    range: YesNo
    required: false
  load_following_up_mss:
    name: load_following_up_mss
    description: "Certifies resources for use in MSS Load Following Up\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.loadFollowingUpMSS
    multivalued: false
    alias: load_following_up_mss
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    range: YesNo
    required: false
  low_control_limit:
    name: low_control_limit
    description: "Low limit for secondary (AGC) control\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.lowControlLImit
    multivalued: false
    alias: low_control_limit
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    - GeneratingUnit
    range: ActivePower
    required: false
  max_dependable_cap:
    name: max_dependable_cap
    description: Maximum Dependable Capacity (MNDC). Maximun Net Dependable Capacity
      is used in association with an RMR contract.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.maxDependableCap
    multivalued: false
    alias: max_dependable_cap
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    range: ActivePower
    required: false
  maximum_allowable_spinning_reserve:
    name: maximum_allowable_spinning_reserve
    description: "Maximum allowable spinning reserve. Spinning reserve will never\
      \ be considered greater than this value regardless of the current operating\
      \ point.\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.maximumAllowableSpinningReserve
    multivalued: false
    alias: maximum_allowable_spinning_reserve
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    - GeneratingUnit
    range: ActivePower
    required: false
  maximum_operating_limit:
    name: maximum_operating_limit
    description: This is the maximum operating MW limit the dispatcher can enter for
      this unit
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.maximumOperatingLimit
    multivalued: false
    alias: maximum_operating_limit
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    range: ActivePower
    required: false
  max_min_load_cost:
    name: max_min_load_cost
    description: "The registered maximum Minimum Load Cost of a Generating Resource\
      \ registered with a Cost Basis of \"Bid Cost\".\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.maxMinLoadCost
    multivalued: false
    alias: max_min_load_cost
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    range: CostRate
    required: false
  max_pumping_level:
    name: max_pumping_level
    description: "max pumping level of a hydro pump unit\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.maxPumpingLevel
    multivalued: false
    alias: max_pumping_level
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    range: ActivePower
    required: false
  max_shutdown_time:
    name: max_shutdown_time
    description: "Maximum time this device can be shut down.\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.maxShutdownTime
    multivalued: false
    alias: max_shutdown_time
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    range: date
    required: false
  max_start_ups_per_day:
    name: max_start_ups_per_day
    description: "maximum start ups per day\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.maxStartUpsPerDay
    multivalued: false
    alias: max_start_ups_per_day
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    range: integer
    required: false
  max_weekly_energy:
    name: max_weekly_energy
    description: "Maximum weekly Energy (Seasonal)\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.maxWeeklyEnergy
    multivalued: false
    alias: max_weekly_energy
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    range: float
    required: false
  max_weekly_starts:
    name: max_weekly_starts
    description: "Maximum weekly starts (seasonal parameter)\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.maxWeeklyStarts
    multivalued: false
    alias: max_weekly_starts
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    range: integer
    required: false
  minimum_load_cost_basis:
    name: minimum_load_cost_basis
    description: The cost basis for minimum load.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.minimumLoadCostBasis
    multivalued: false
    alias: minimum_load_cost_basis
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    range: CostBasis
    required: false
  minimum_load_fuel_cost:
    name: minimum_load_fuel_cost
    description: "The cost for the fuel required to get a Generating Resource to operate\
      \ at the minimum load level\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.minimumLoadFuelCost
    multivalued: false
    alias: minimum_load_fuel_cost
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    range: CostPerHeatUnit
    required: false
  minimum_operating_limit:
    name: minimum_operating_limit
    description: This is the minimum operating MW limit the dispatcher can enter for
      this unit.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.minimumOperatingLimit
    multivalued: false
    alias: minimum_operating_limit
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    range: ActivePower
    required: false
  min_load_cost:
    name: min_load_cost
    description: "minimum load cost. Value is (currency/hr)\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.minLoadCost
    multivalued: false
    alias: min_load_cost
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    - DefaultBid
    range: CostRate
    required: false
  must_offer_ra:
    name: must_offer_ra
    description: "Flag to indicate that this unit is a resource adequacy resource\
      \ and must offer.\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.mustOfferRA
    multivalued: false
    alias: must_offer_ra
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    range: YesNo
    required: false
  nameplate_capacity:
    name: nameplate_capacity
    description: "MW value stated on the nameplate of the Generator -- the value it\
      \ potentially could provide.\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.nameplateCapacity
    multivalued: false
    alias: nameplate_capacity
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    range: ActivePower
    required: false
  operating_maintenance_cost:
    name: operating_maintenance_cost
    description: "The portion of the Operating Cost of a Generating Resource that\
      \ is not related to fuel cost.\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.operatingMaintenanceCost
    multivalued: false
    alias: operating_maintenance_cost
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    range: CostPerEnergyUnit
    required: false
  pumping_cost:
    name: pumping_cost
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.pumpingCost
    multivalued: false
    alias: pumping_cost
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    range: CostRate
    required: false
  pumping_factor:
    name: pumping_factor
    description: "Pumping factor for pump storage units, conversion factor between\
      \ generating and pumping.\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.pumpingFactor
    multivalued: false
    alias: pumping_factor
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    range: float
    required: false
  pump_min_down_time:
    name: pump_min_down_time
    description: "The minimum down time for the pump in a pump storage unit.\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.pumpMinDownTime
    multivalued: false
    alias: pump_min_down_time
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    range: float
    required: false
  pump_min_up_time:
    name: pump_min_up_time
    description: "The minimum up time aspect for the pump in a pump storage unit\r\
      \n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.pumpMinUpTime
    multivalued: false
    alias: pump_min_up_time
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    range: float
    required: false
  pump_shutdown_cost:
    name: pump_shutdown_cost
    description: "The cost to shutdown a pump during the pump aspect of a pump storage\
      \ unit.\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.pumpShutdownCost
    multivalued: false
    alias: pump_shutdown_cost
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    range: float
    required: false
  pump_shutdown_time:
    name: pump_shutdown_time
    description: "The shutdown time (minutes) of the pump aspect of a pump storage\
      \ unit.\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.pumpShutdownTime
    multivalued: false
    alias: pump_shutdown_time
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    range: integer
    required: false
  quick_start_flag:
    name: quick_start_flag
    description: Quick start flag (Yes/No). Identifies the registered generator as
      a quick start unit. A quick start unit is a unit that has the ability to be
      available for load within a 30 minute period.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.quickStartFlag
    multivalued: false
    alias: quick_start_flag
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    range: YesNo
    required: false
  ramp_curve_type:
    name: ramp_curve_type
    description: Ramp curve type. Identifies the type of curve which may be a fixed,
      static or dynamic.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.rampCurveType
    multivalued: false
    alias: ramp_curve_type
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    - GeneratingBid
    range: RampCurveType
    required: false
  regulation_down_ramp_rate:
    name: regulation_down_ramp_rate
    description: Regulation down response rate in MW per minute
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.regulationDownRampRate
    multivalued: false
    alias: regulation_down_ramp_rate
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    range: ActivePowerChangeRate
    required: false
  regulation_flag:
    name: regulation_flag
    description: Specifies if the unit is regulating or not regulating or expected
      to be regulating but is not.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.regulationFlag
    multivalued: false
    alias: regulation_flag
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    range: UnitRegulationKind
    required: false
  regulation_up_ramp_rate:
    name: regulation_up_ramp_rate
    description: Regulation up response rate in MW per minute.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.regulationUpRampRate
    multivalued: false
    alias: regulation_up_ramp_rate
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    range: ActivePowerChangeRate
    required: false
  resource_sub_type:
    name: resource_sub_type
    description: Unit sub type used by Settlements or scheduling application. Application
      use of the unit sub type may define the necessary types as applicable.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.resourceSubType
    multivalued: false
    alias: resource_sub_type
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    range: string
    required: false
  river_system:
    name: river_system
    description: "River System the Resource is tied to.\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.riverSystem
    multivalued: false
    alias: river_system
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    range: string
    required: false
  rmnrflag:
    name: rmnrflag
    description: "Reliability must not run (RMNR) flag: indicated whether the RMR\
      \ unit is set as an RMNR in the current market\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.RMNRFlag
    multivalued: false
    alias: rmnrflag
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    range: YesNo
    required: false
  rmrflag:
    name: rmrflag
    description: "Reliability must run (RMR) flag: indicates whether the unit is RMR;\
      \ Indicates whether the unit is RMR:\r\nN' - not an RMR unit\r\n'1' - RMR Condition\
      \ 1 unit\r\n'2' - RMR Condition 2 unit\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.RMRFlag
    multivalued: false
    alias: rmrflag
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    range: FlagTypeRMR
    required: false
  rmrmanual_indicator:
    name: rmrmanual_indicator
    description: "Indicates the RMR Manual pre-determination status [Y/N]\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.RMRManualIndicator
    multivalued: false
    alias: rmrmanual_indicator
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    range: YesNo
    required: false
  rmtflag:
    name: rmtflag
    description: "Reliability must take (RMT) flag (Yes/No): indicates whether the\
      \ unit is RMT\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.RMTFlag
    multivalued: false
    alias: rmtflag
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    range: YesNo
    required: false
  spin_ramp_rate:
    name: spin_ramp_rate
    description: Response rate in MW per minute for spinning reserve.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.spinRampRate
    multivalued: false
    alias: spin_ramp_rate
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    range: ActivePowerChangeRate
    required: false
  start_up_cost_basis:
    name: start_up_cost_basis
    description: The cost basis for start up.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.startUpCostBasis
    multivalued: false
    alias: start_up_cost_basis
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    range: CostBasis
    required: false
  sync_cond_capable:
    name: sync_cond_capable
    description: "Is the Resource Synchronous Condenser capable Resource? \r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.syncCondCapable
    multivalued: false
    alias: sync_cond_capable
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    range: YesNo
    required: false
  unit_type:
    name: unit_type
    description: "Generating unit type: Combined Cycle, Gas Turbine, Hydro Turbine,\
      \ Other, Photovoltaic, Hydro Pump-Turbine, Reciprocating Engine, Steam Turbine,\
      \ Synchronous Condenser, Wind Turbine\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.unitType
    multivalued: false
    alias: unit_type
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    range: UnitType
    required: false
  use_limit_flag:
    name: use_limit_flag
    description: "Use limit flag: indicates if the use-limited resource is fully scheduled\
      \ (or has some slack for real-time dispatch) (Y/N)\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.useLimitFlag
    multivalued: false
    alias: use_limit_flag
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    range: YesNo
    required: false
  variable_energy_resource:
    name: variable_energy_resource
    description: Provides an indication that this resource is intending to participate
      in an intermittent resource program.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.variableEnergyResource
    multivalued: false
    alias: variable_energy_resource
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    range: YesNo
    required: false
  trade:
    name: trade
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:RegisteredGenerator.Trade
    multivalued: true
    alias: trade
    owner: RegisteredGenerator
    domain_of:
    - Pnode
    - RegisteredGenerator
    - ActionRequest
    - TradeProduct
    - TradeError
    range: Trade
    required: false
  mkt_heat_rate_curve:
    name: mkt_heat_rate_curve
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.MktHeatRateCurve
    multivalued: false
    alias: mkt_heat_rate_curve
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    - ResourceVerifiableCosts
    range: MktHeatRateCurve
    required: false
  rmrstart_up_energy_curve:
    name: rmrstart_up_energy_curve
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.RMRStartUpEnergyCurve
    multivalued: false
    alias: rmrstart_up_energy_curve
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    range: RMRStartUpEnergyCurve
    required: false
  rmrstart_up_time_curve:
    name: rmrstart_up_time_curve
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.RMRStartUpTimeCurve
    multivalued: false
    alias: rmrstart_up_time_curve
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    range: RMRStartUpTimeCurve
    required: false
  start_up_energy_curve:
    name: start_up_energy_curve
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.StartUpEnergyCurve
    multivalued: false
    alias: start_up_energy_curve
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    range: StartUpEnergyCurve
    required: false
  start_up_time_curve:
    name: start_up_time_curve
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.StartUpTimeCurve
    multivalued: false
    alias: start_up_time_curve
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    - GeneratingBid
    range: StartUpTimeCurve
    required: false
  regulating_limit:
    name: regulating_limit
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.RegulatingLimit
    multivalued: false
    alias: regulating_limit
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    range: RegulatingLimit
    required: false
  start_up_fuel_curve:
    name: start_up_fuel_curve
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.StartUpFuelCurve
    multivalued: false
    alias: start_up_fuel_curve
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    range: StartUpFuelCurve
    required: false
  generating_bids:
    name: generating_bids
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.GeneratingBids
    multivalued: true
    alias: generating_bids
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    - NotificationTimeCurve
    - BidSet
    range: GeneratingBid
    required: false
  rmrstart_up_cost_curve:
    name: rmrstart_up_cost_curve
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.RMRStartUpCostCurve
    multivalued: false
    alias: rmrstart_up_cost_curve
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    range: RMRStartUpCostCurve
    required: false
  rmrstart_up_fuel_curve:
    name: rmrstart_up_fuel_curve
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.RMRStartUpFuelCurve
    multivalued: false
    alias: rmrstart_up_fuel_curve
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    range: RMRStartUpFuelCurve
    required: false
  rmrheat_rate_curve:
    name: rmrheat_rate_curve
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.RMRHeatRateCurve
    multivalued: false
    alias: rmrheat_rate_curve
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    range: RMRHeatRateCurve
    required: false
  fuel_region:
    name: fuel_region
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:RegisteredGenerator.FuelRegion
    multivalued: false
    alias: fuel_region
    owner: RegisteredGenerator
    domain_of:
    - RTO
    - RegisteredGenerator
    - GasPrice
    - OilPrice
    range: FuelRegion
    required: false
  local_reliability_area:
    name: local_reliability_area
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:RegisteredGenerator.LocalReliabilityArea
    multivalued: false
    alias: local_reliability_area
    owner: RegisteredGenerator
    domain_of:
    - RTO
    - RegisteredGenerator
    range: LocalReliabilityArea
    required: false
  start_up_cost_curves:
    name: start_up_cost_curves
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.StartUpCostCurves
    multivalued: true
    alias: start_up_cost_curves
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    range: StartUpCostCurve
    required: false
  energy_price_index:
    name: energy_price_index
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.EnergyPriceIndex
    multivalued: false
    alias: energy_price_index
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    - EnergyPriceIndex
    range: EnergyPriceIndex
    required: true
  auxillary_object:
    name: auxillary_object
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.AuxillaryObject
    multivalued: true
    alias: auxillary_object
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    - RegisteredLoad
    range: AuxiliaryObject
    required: false
  fuel_cost_curve:
    name: fuel_cost_curve
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.FuelCostCurve
    multivalued: false
    alias: fuel_cost_curve
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    range: FuelCostCurve
    required: false
  unit_initial_conditions:
    name: unit_initial_conditions
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredGenerator.UnitInitialConditions
    multivalued: true
    alias: unit_initial_conditions
    owner: RegisteredGenerator
    domain_of:
    - RegisteredGenerator
    range: UnitInitialConditions
    required: false
  acaflag:
    name: acaflag
    description: "Indication that this resource is associated with an Adjacent Control\
      \ Area.\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredResource.ACAFlag
    multivalued: false
    alias: acaflag
    owner: RegisteredGenerator
    domain_of:
    - RegisteredResource
    range: YesNo
    required: false
  asspoptimization_flag:
    name: asspoptimization_flag
    description: "Indication that the resource participates in the optimization process\
      \ by default.\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredResource.ASSPOptimizationFlag
    multivalued: false
    alias: asspoptimization_flag
    owner: RegisteredGenerator
    domain_of:
    - RegisteredResource
    range: YesNo
    required: false
  commercial_op_date:
    name: commercial_op_date
    description: "Resource Commercial Operation Date. \r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredResource.commercialOpDate
    multivalued: false
    alias: commercial_op_date
    owner: RegisteredGenerator
    domain_of:
    - RegisteredResource
    range: date
    required: false
  contingency_avail_flag:
    name: contingency_avail_flag
    description: "Contingent operating reserve availiability (Yes/No).  Resource is\
      \ availiable to participate with capacity in contingency dispatch.\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredResource.contingencyAvailFlag
    multivalued: false
    alias: contingency_avail_flag
    owner: RegisteredGenerator
    domain_of:
    - RegisteredResource
    - ResourceBid
    range: YesNo
    required: false
  dispatchable:
    name: dispatchable
    description: 'Dispatchable: indicates whether the resource is dispatchable. This
      implies that the resource intends to submit Energy bids/offers or Ancillary
      Services bids/offers, or self-provided schedules.'
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredResource.dispatchable
    multivalued: false
    alias: dispatchable
    owner: RegisteredGenerator
    domain_of:
    - RegisteredResource
    - TransactionBid
    range: boolean
    required: false
  ecaflag:
    name: ecaflag
    description: "Indication that this resource is associated with an Embedded Control\
      \ area.\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredResource.ECAFlag
    multivalued: false
    alias: ecaflag
    owner: RegisteredGenerator
    domain_of:
    - RegisteredResource
    range: YesNo
    required: false
  flexible_offer_flag:
    name: flexible_offer_flag
    description: "Flexible offer flag (Y/N).\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredResource.flexibleOfferFlag
    multivalued: false
    alias: flexible_offer_flag
    owner: RegisteredGenerator
    domain_of:
    - RegisteredResource
    range: YesNo
    required: false
  hourly_predispatch:
    name: hourly_predispatch
    description: "Indicates need to dispatch before the start of the operating hour.\
      \ Only relevant in Real-Time Market. Applies to generation, intertie and participating\
      \ load resource. Value (Y/N).\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredResource.hourlyPredispatch
    multivalued: false
    alias: hourly_predispatch
    owner: RegisteredGenerator
    domain_of:
    - RegisteredResource
    range: YesNo
    required: false
  is_aggregated_res:
    name: is_aggregated_res
    description: "A flag to indicate if a resource is an aggregated resource.\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredResource.isAggregatedRes
    multivalued: false
    alias: is_aggregated_res
    owner: RegisteredGenerator
    domain_of:
    - RegisteredResource
    range: YesNo
    required: false
  last_modified:
    name: last_modified
    description: "Indication of the last time this item was modified/versioned.\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredResource.lastModified
    multivalued: false
    alias: last_modified
    owner: RegisteredGenerator
    domain_of:
    - RegisteredResource
    - SchedulingCoordinator
    - Trade
    - FuelRegion
    - EnergyPriceIndex
    range: date
    required: false
  lmpmflag:
    name: lmpmflag
    description: "LMPM flag: indicates whether the resource is subject to the LMPM\
      \ test (Yes/No).\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredResource.LMPMFlag
    multivalued: false
    alias: lmpmflag
    owner: RegisteredGenerator
    domain_of:
    - RegisteredResource
    range: YesNo
    required: false
  market_participation_flag:
    name: market_participation_flag
    description: 'Market Participation flag: indicates whether the resource participate
      in the market.'
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredResource.marketParticipationFlag
    multivalued: false
    alias: market_participation_flag
    owner: RegisteredGenerator
    domain_of:
    - RegisteredResource
    range: YesNo
    required: false
  max_base_self_sched_qty:
    name: max_base_self_sched_qty
    description: "Maximum base self schedule quantity.\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredResource.maxBaseSelfSchedQty%20
    multivalued: false
    alias: max_base_self_sched_qty
    owner: RegisteredGenerator
    domain_of:
    - RegisteredResource
    range: float
    required: false
  max_on_time:
    name: max_on_time
    description: "Maximum on time after start up.\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredResource.maxOnTime
    multivalued: false
    alias: max_on_time
    owner: RegisteredGenerator
    domain_of:
    - RegisteredResource
    range: float
    required: false
  min_dispatch_time:
    name: min_dispatch_time
    description: 'Minimum number of consecutive hours a resource shall be dispatched
      if bid is accepted.  '
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredResource.minDispatchTime
    multivalued: false
    alias: min_dispatch_time
    owner: RegisteredGenerator
    domain_of:
    - RegisteredResource
    - ResourceBid
    range: Hours
    required: false
  min_off_time:
    name: min_off_time
    description: "Minimum off time after shut down.\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredResource.minOffTime
    multivalued: false
    alias: min_off_time
    owner: RegisteredGenerator
    domain_of:
    - RegisteredResource
    range: float
    required: false
  min_on_time:
    name: min_on_time
    description: "Minimum on time after start up.\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredResource.minOnTime
    multivalued: false
    alias: min_on_time
    owner: RegisteredGenerator
    domain_of:
    - RegisteredResource
    range: float
    required: false
  must_offer_flag:
    name: must_offer_flag
    description: "Must offer flag: indicates whether the unit is subject to the must\
      \ offer provisions (Y/N).\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredResource.mustOfferFlag
    multivalued: false
    alias: must_offer_flag
    owner: RegisteredGenerator
    domain_of:
    - RegisteredResource
    range: YesNo
    required: false
  non_market:
    name: non_market
    description: "Flag to indicate that the Resource is not participating in the Market\
      \ Operations.\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredResource.nonMarket
    multivalued: false
    alias: non_market
    owner: RegisteredGenerator
    domain_of:
    - RegisteredResource
    range: YesNo
    required: false
  point_of_delivery_flag:
    name: point_of_delivery_flag
    description: "Indication that the registered resource is a Point of Delivery (YES)\
      \ resource which implies there is a POD Loss Factor.\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredResource.pointOfDeliveryFlag
    multivalued: false
    alias: point_of_delivery_flag
    owner: RegisteredGenerator
    domain_of:
    - RegisteredResource
    range: YesNo
    required: false
  price_set_flag_da:
    name: price_set_flag_da
    description: "Price setting flag: indicates whether a resource is capable of setting\
      \ the Market Clearing Price (Y) for the DA market, and if not, indicates whether\
      \ the resource shall submit bids for energy at $ 0 (S) or not (N).\r\n\r\nInitially\
      \ in the RegisteredGenerator class. It was moved to the RegisteredResource class\
      \ for the participating load dispatch purpose."
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredResource.priceSetFlagDA
    multivalued: false
    alias: price_set_flag_da
    owner: RegisteredGenerator
    domain_of:
    - RegisteredResource
    range: YesNo
    required: false
  price_set_flag_rt:
    name: price_set_flag_rt
    description: "Price setting flag: indicates whether a resource is capable of setting\
      \ the Market Clearing Price (Y) for the RT market, and if not, indicates whether\
      \ the resource shall submit bids for energy at $ 0 (S) or not (N).\r\n\r\nInitially\
      \ in the RegisteredGenerator class. It was moved to the RegisteredResource class\
      \ for the participating load dispatch purpose."
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredResource.priceSetFlagRT
    multivalued: false
    alias: price_set_flag_rt
    owner: RegisteredGenerator
    domain_of:
    - RegisteredResource
    range: YesNo
    required: false
  registration_status:
    name: registration_status
    description: "Registration Status of resource - Active, Mothballed, Planned, or\
      \ Decommissioned.\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredResource.registrationStatus
    multivalued: false
    alias: registration_status
    owner: RegisteredGenerator
    domain_of:
    - RegisteredResource
    range: ResourceRegistrationStatus
    required: false
  resource_adequacy_flag:
    name: resource_adequacy_flag
    description: "Indication that this resource participates in the resource adequacy\
      \ function.\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredResource.resourceAdequacyFlag
    multivalued: false
    alias: resource_adequacy_flag
    owner: RegisteredGenerator
    domain_of:
    - RegisteredResource
    range: YesNo
    required: false
  smpmflag:
    name: smpmflag
    description: "SMPM flag: indicates whether the resource is subject to the SMPM\
      \ test (Yes/No).\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredResource.SMPMFlag
    multivalued: false
    alias: smpmflag
    owner: RegisteredGenerator
    domain_of:
    - RegisteredResource
    range: YesNo
    required: false
  dop_instruction:
    name: dop_instruction
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredResource.DopInstruction
    multivalued: true
    alias: dop_instruction
    owner: RegisteredGenerator
    domain_of:
    - RegisteredResource
    - InstructionClearingDOP
    range: DopInstruction
    required: false
  resource_groups:
    name: resource_groups
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredResource.ResourceGroups
    multivalued: true
    alias: resource_groups
    owner: RegisteredGenerator
    domain_of:
    - RegisteredResource
    range: ResourceGroup
    required: false
  resource_certification:
    name: resource_certification
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredResource.ResourceCertification
    multivalued: true
    alias: resource_certification
    owner: RegisteredGenerator
    domain_of:
    - RegisteredResource
    range: ResourceCertification
    required: false
  mkt_connectivity_node:
    name: mkt_connectivity_node
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredResource.MktConnectivityNode
    multivalued: false
    alias: mkt_connectivity_node
    owner: RegisteredGenerator
    domain_of:
    - RegisteredResource
    - RTO
    - SysLoadDistributionFactor
    - IndividualPnode
    - CnodeDistributionFactor
    - LossSensitivity
    - NodeConstraintTerm
    range: MktConnectivityNode
    required: false
  inter_tie:
    name: inter_tie
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredResource.InterTie
    multivalued: true
    alias: inter_tie
    owner: RegisteredGenerator
    domain_of:
    - RegisteredResource
    - Flowgate
    - InterchangeSchedule
    range: SchedulingPoint
    required: false
  former_reference:
    name: former_reference
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredResource.FormerReference
    multivalued: true
    alias: former_reference
    owner: RegisteredGenerator
    domain_of:
    - RegisteredResource
    range: FormerReference
    required: false
  intermittent_resource_eligibility:
    name: intermittent_resource_eligibility
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredResource.IntermittentResourceEligibility
    multivalued: true
    alias: intermittent_resource_eligibility
    owner: RegisteredGenerator
    domain_of:
    - RegisteredResource
    range: IntermittentResourceEligibility
    required: false
  resource_capacity:
    name: resource_capacity
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredResource.ResourceCapacity
    multivalued: true
    alias: resource_capacity
    owner: RegisteredGenerator
    domain_of:
    - RegisteredResource
    range: ResourceCapacity
    required: false
  reason:
    name: reason
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:RegisteredResource.Reason
    multivalued: true
    alias: reason
    owner: RegisteredGenerator
    domain_of:
    - Status
    - PlannedOutage
    - ActivityRecord
    - AccountMovement
    - Reading
    - EndDeviceControl
    - MetrologyRequirement
    - TimeSeries
    - MarketDocument
    - Point
    - RegisteredResource
    - EnergyTransaction
    - Period
    range: Reason
    required: false
  expected_energy_values:
    name: expected_energy_values
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredResource.ExpectedEnergyValues
    multivalued: true
    alias: expected_energy_values
    owner: RegisteredGenerator
    domain_of:
    - RegisteredResource
    - ExpectedEnergy
    range: ExpectedEnergyValues
    required: false
  resource_ancillary_service_qualification:
    name: resource_ancillary_service_qualification
    description: RegisteredResources are qualified for resource ancillary service
      types (which include market product types as well as other types such as BlackStart)
      by the association to the class ResourceAncillaryServiceQualification.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredResource.ResourceAncillaryServiceQualification
    multivalued: true
    alias: resource_ancillary_service_qualification
    owner: RegisteredGenerator
    domain_of:
    - RegisteredResource
    range: ResourceCertification
    required: false
  resource_load_following_inst:
    name: resource_load_following_inst
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredResource.ResourceLoadFollowingInst
    multivalued: true
    alias: resource_load_following_inst
    owner: RegisteredGenerator
    domain_of:
    - RegisteredResource
    - ResourceClearing
    range: ResourceLoadFollowingInst
    required: false
  load_following_inst:
    name: load_following_inst
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredResource.LoadFollowingInst
    multivalued: true
    alias: load_following_inst
    owner: RegisteredGenerator
    domain_of:
    - RegisteredResource
    range: LoadFollowingInst
    required: false
  allocation_result_values:
    name: allocation_result_values
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredResource.AllocationResultValues
    multivalued: true
    alias: allocation_result_values
    owner: RegisteredGenerator
    domain_of:
    - RegisteredResource
    - AllocationResult
    range: AllocationResultValues
    required: false
  rucaward_instruction:
    name: rucaward_instruction
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredResource.RUCAwardInstruction
    multivalued: true
    alias: rucaward_instruction
    owner: RegisteredGenerator
    domain_of:
    - RegisteredResource
    - ResourceAwardClearing
    range: RUCAwardInstruction
    required: false
  mpmresource_status:
    name: mpmresource_status
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredResource.MPMResourceStatus
    multivalued: true
    alias: mpmresource_status
    owner: RegisteredGenerator
    domain_of:
    - RegisteredResource
    - MitigatedBidClearing
    - MPMTestCategory
    range: MPMResourceStatus
    required: false
  commitments:
    name: commitments
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredResource.Commitments
    multivalued: true
    alias: commitments
    owner: RegisteredGenerator
    domain_of:
    - RegisteredResource
    - CommitmentClearing
    range: Commitments
    required: false
  market_participant:
    name: market_participant
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:RegisteredResource.MarketParticipant
    multivalued: false
    alias: market_participant
    owner: RegisteredGenerator
    domain_of:
    - TimeSeries
    - MarketDocument
    - RegisteredResource
    - Bid
    - SchedulingCoordinator
    - MarketRole
    - MarketPerson
    range: MarketParticipant
    required: false
  sub_control_area:
    name: sub_control_area
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredResource.SubControlArea
    multivalued: true
    alias: sub_control_area
    owner: RegisteredGenerator
    domain_of:
    - RegisteredResource
    - RTO
    - Pnode
    - AdjacentCASet
    - BidSelfSched
    - CnodeDistributionFactor
    - AggregateNode
    - LossClearingResults
    - InadvertentAccount
    - ExPostLossResults
    - ControlAreaDesignation
    - AreaReserveSpec
    - GeneralClearingResults
    range: SubControlArea
    required: false
  adjacent_caset:
    name: adjacent_caset
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredResource.AdjacentCASet
    multivalued: false
    alias: adjacent_caset
    owner: RegisteredGenerator
    domain_of:
    - RegisteredResource
    - RTO
    - SubControlArea
    - HostControlArea
    - BidSelfSched
    range: AdjacentCASet
    required: false
  substitution_resource_list:
    name: substitution_resource_list
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredResource.SubstitutionResourceList
    multivalued: true
    alias: substitution_resource_list
    owner: RegisteredGenerator
    domain_of:
    - RegisteredResource
    - ContractRight
    range: SubstitutionResourceList
    required: false
  resource_dispatch_results:
    name: resource_dispatch_results
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredResource.ResourceDispatchResults
    multivalued: true
    alias: resource_dispatch_results
    owner: RegisteredGenerator
    domain_of:
    - RegisteredResource
    - ResourceClearing
    range: ResourceDispatchResults
    required: false
  rmroperator_input:
    name: rmroperator_input
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredResource.RMROperatorInput
    multivalued: true
    alias: rmroperator_input
    owner: RegisteredGenerator
    domain_of:
    - RegisteredResource
    range: RMROperatorInput
    required: false
  org_res_ownership:
    name: org_res_ownership
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredResource.OrgResOwnership
    multivalued: true
    alias: org_res_ownership
    owner: RegisteredGenerator
    domain_of:
    - RegisteredResource
    range: OrgResOwnership
    required: false
  contract_distribution_factor:
    name: contract_distribution_factor
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredResource.ContractDistributionFactor
    multivalued: true
    alias: contract_distribution_factor
    owner: RegisteredGenerator
    domain_of:
    - RegisteredResource
    - Flowgate
    - ContractRight
    range: ContractDistributionFactor
    required: false
  ramp_rate_curve:
    name: ramp_rate_curve
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredResource.RampRateCurve
    multivalued: true
    alias: ramp_rate_curve
    owner: RegisteredGenerator
    domain_of:
    - RegisteredResource
    - GeneratingBid
    - InterTieBid
    - LoadBid
    range: RampRateCurve
    required: false
  time_series:
    name: time_series
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:RegisteredResource.TimeSeries
    multivalued: true
    alias: time_series
    owner: RegisteredGenerator
    domain_of:
    - EnvironmentalMonitoringStation
    - ConstraintDuration
    - AttributeInstanceComponent
    - MarketDocument
    - Point
    - Reason
    - RegisteredResource
    - MarketParticipant
    - Domain
    - Quantity
    - Price
    - MarketObjectStatus
    - Period
    - FlowDirection
    - Unit
    - DateAndOrTime
    - Auction
    - MktPSRType
    - MarketEvaluationPoint
    range: TimeSeries
    required: false
  dispatch_inst_reply:
    name: dispatch_inst_reply
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredResource.DispatchInstReply
    multivalued: true
    alias: dispatch_inst_reply
    owner: RegisteredGenerator
    domain_of:
    - RegisteredResource
    range: DispatchInstReply
    required: false
  aggregate_node:
    name: aggregate_node
    description: An AggregateNode may be associated with up to many RegisteredResources.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredResource.AggregateNode
    multivalued: false
    alias: aggregate_node
    owner: RegisteredGenerator
    domain_of:
    - RegisteredResource
    - RTO
    - Pnode
    - SubControlArea
    - CnodeDistributionFactor
    - AreaLoadCurve
    - Instructions
    range: AggregateNode
    required: false
  forbidden_region:
    name: forbidden_region
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredResource.ForbiddenRegion
    multivalued: true
    alias: forbidden_region
    owner: RegisteredGenerator
    domain_of:
    - RegisteredResource
    range: ForbiddenRegion
    required: false
  dot_instruction:
    name: dot_instruction
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredResource.DotInstruction
    multivalued: true
    alias: dot_instruction
    owner: RegisteredGenerator
    domain_of:
    - RegisteredResource
    - InstructionClearingDOT
    range: DotInstruction
    required: false
  energy_markets:
    name: energy_markets
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredResource.EnergyMarkets
    multivalued: true
    alias: energy_markets
    owner: RegisteredGenerator
    domain_of:
    - RegisteredResource
    - RTO
    range: EnergyMarket
    required: false
  domain:
    name: domain
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:RegisteredResource.Domain
    multivalued: true
    alias: domain
    owner: RegisteredGenerator
    domain_of:
    - EndDeviceEventType
    - EndDeviceControlType
    - TimeSeries
    - MarketDocument
    - RegisteredResource
    - Quantity
    - Price
    range: Domain
    required: false
  instructions:
    name: instructions
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredResource.Instructions
    multivalued: true
    alias: instructions
    owner: RegisteredGenerator
    domain_of:
    - RegisteredResource
    - InstructionClearing
    range: Instructions
    required: false
  host_control_area:
    name: host_control_area
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredResource.HostControlArea
    multivalued: false
    alias: host_control_area
    owner: RegisteredGenerator
    domain_of:
    - RegisteredResource
    - RTO
    - Flowgate
    - SubControlArea
    - AdjacentCASet
    - SysLoadDistributionFactor
    - BidSelfSched
    - CnodeDistributionFactor
    - TransferInterface
    - LossClearingResults
    range: HostControlArea
    required: false
  pnode:
    name: pnode
    description: A registered resource injects power at one or more connectivity nodes
      related to a pnode
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredResource.Pnode
    multivalued: false
    alias: pnode
    owner: RegisteredGenerator
    domain_of:
    - RegisteredResource
    - CommodityDefinition
    - MktMeasurement
    - SubControlArea
    - Trade
    - AggregateNode
    - OrgPnodeAllocation
    - PnodeResults
    - ExPostPricingResults
    range: Pnode
    required: false
  ex_post_resource_results:
    name: ex_post_resource_results
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredResource.ExPostResourceResults
    multivalued: true
    alias: ex_post_resource_results
    owner: RegisteredGenerator
    domain_of:
    - RegisteredResource
    - ExPostResource
    range: ExPostResourceResults
    required: false
  resource_award_instruction:
    name: resource_award_instruction
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredResource.ResourceAwardInstruction
    multivalued: true
    alias: resource_award_instruction
    owner: RegisteredGenerator
    domain_of:
    - RegisteredResource
    - MarketProduct
    - ResourceAwardClearing
    - SelfScheduleBreakdown
    range: ResourceAwardInstruction
    required: false
  mpmtest_threshold:
    name: mpmtest_threshold
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredResource.MPMTestThreshold
    multivalued: true
    alias: mpmtest_threshold
    owner: RegisteredGenerator
    domain_of:
    - RegisteredResource
    - MPMTestCategory
    - AggregatedPnode
    range: MPMTestThreshold
    required: false
  load_following_operator_input:
    name: load_following_operator_input
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredResource.LoadFollowingOperatorInput
    multivalued: true
    alias: load_following_operator_input
    owner: RegisteredGenerator
    domain_of:
    - RegisteredResource
    range: LoadFollowingOperatorInput
    required: false
  control_area_designation:
    name: control_area_designation
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredResource.ControlAreaDesignation
    multivalued: true
    alias: control_area_designation
    owner: RegisteredGenerator
    domain_of:
    - RegisteredResource
    - SubControlArea
    range: ControlAreaDesignation
    required: false
  market_object_status:
    name: market_object_status
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:RegisteredResource.MarketObjectStatus
    multivalued: true
    alias: market_object_status
    owner: RegisteredGenerator
    domain_of:
    - TimeSeries
    - RegisteredResource
    range: MarketObjectStatus
    required: false
  default_bid:
    name: default_bid
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredResource.DefaultBid
    multivalued: false
    alias: default_bid
    owner: RegisteredGenerator
    domain_of:
    - RegisteredResource
    - DefaultBidCurve
    range: DefaultBid
    required: false
  resource_verifiable_costs:
    name: resource_verifiable_costs
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:RegisteredResource.ResourceVerifiableCosts
    multivalued: false
    alias: resource_verifiable_costs
    owner: RegisteredGenerator
    domain_of:
    - RegisteredResource
    - MktHeatRateCurve
    - ResourceStartupCost
    - ResourceOperationMaintenanceCost
    range: ResourceVerifiableCosts
    required: false
  controls:
    name: controls
    description: The controller outputs used to actually govern a regulating device,
      e.g. the magnetization of a synchronous machine or capacitor bank breaker actuator.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PowerSystemResource.Controls
    multivalued: true
    alias: controls
    owner: RegisteredGenerator
    domain_of:
    - PowerSystemResource
    - HostControlArea
    range: Control
    required: false
  measurements:
    name: measurements
    description: The measurements associated with this power system resource.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PowerSystemResource.Measurements
    multivalued: true
    alias: measurements
    owner: RegisteredGenerator
    domain_of:
    - PowerSystemResource
    - ACDCTerminal
    - Asset
    - Location
    - Procedure
    - AnalogLimitSet
    - AccumulatorLimitSet
    range: Measurement
    required: false
  psrtype:
    name: psrtype
    description: Custom classification for this power system resource.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PowerSystemResource.PSRType
    multivalued: false
    alias: psrtype
    owner: RegisteredGenerator
    domain_of:
    - PowerSystemResource
    range: PSRType
    required: false
  configuration_event:
    name: configuration_event
    description: All configuration events created for this Power System resource.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PowerSystemResource.ConfigurationEvent
    multivalued: true
    alias: configuration_event
    owner: RegisteredGenerator
    domain_of:
    - PowerSystemResource
    - FaultCauseType
    range: ConfigurationEvent
    required: false
  reporting_group:
    name: reporting_group
    description: Reporting groups to which this power system resource belongs.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PowerSystemResource.ReportingGroup
    multivalued: true
    alias: reporting_group
    owner: RegisteredGenerator
    domain_of:
    - PowerSystemResource
    - BusNameMarker
    - TopologicalNode
    - ReportingSuperGroup
    range: ReportingGroup
    required: false
  operating_share:
    name: operating_share
    description: The operating shares of this power system resource.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PowerSystemResource.OperatingShare
    multivalued: true
    alias: operating_share
    owner: RegisteredGenerator
    domain_of:
    - PowerSystemResource
    - OperatingParticipant
    range: OperatingShare
    required: false
  asset_datasheet:
    name: asset_datasheet
    description: Datasheet information for this power system resource.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PowerSystemResource.AssetDatasheet
    multivalued: false
    alias: asset_datasheet
    owner: RegisteredGenerator
    domain_of:
    - PowerSystemResource
    range: AssetInfo
    required: false
  verification_action:
    name: verification_action
    description: The verification action that is performed on the power system resource
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PowerSystemResource.VerificationAction
    multivalued: true
    alias: verification_action
    owner: RegisteredGenerator
    domain_of:
    - PowerSystemResource
    range: VerificationAction
    required: false
  clearances:
    name: clearances
    description: All clearances applicable to this power system resource.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PowerSystemResource.Clearances
    multivalued: true
    alias: clearances
    owner: RegisteredGenerator
    domain_of:
    - PowerSystemResource
    range: ClearanceDocument
    required: false
  generic_action:
    name: generic_action
    description: The generic action that is performed on the power system resource
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PowerSystemResource.GenericAction
    multivalued: true
    alias: generic_action
    owner: RegisteredGenerator
    domain_of:
    - PowerSystemResource
    range: GenericAction
    required: false
  psrevents:
    name: psrevents
    description: All events associated with this power system resource.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PowerSystemResource.PSREvents
    multivalued: true
    alias: psrevents
    owner: RegisteredGenerator
    domain_of:
    - PowerSystemResource
    range: PSREvent
    required: false
  assets:
    name: assets
    description: All assets represented by this power system resource. For example,
      multiple conductor assets are electrically modelled as a single AC line segment.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PowerSystemResource.Assets
    multivalued: true
    alias: assets
    owner: RegisteredGenerator
    domain_of:
    - PowerSystemResource
    - AssetInfo
    - Location
    - WorkTask
    - ErpRecDelvLineItem
    - AssetContainer
    - ActivityRecord
    - Procedure
    - ReliabilityInfo
    - AssetPropertyCurve
    - AssetOrganisationRole
    - ScheduledEvent
    range: Asset
    required: false
  location:
    name: location
    description: Location of this power system resource.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PowerSystemResource.Location
    multivalued: false
    alias: location
    owner: RegisteredGenerator
    domain_of:
    - PowerSystemResource
    - Asset
    - Incident
    - SwitchingOrder
    - TroubleOrder
    - Crew
    - Fault
    - PointOfSale
    - TroubleTicket
    - OutageOrder
    - EnvironmentalMonitoringStation
    - EnvironmentalLocationType
    - PositionPoint
    - FailureEvent
    range: Location
    required: false
  operational_tags:
    name: operational_tags
    description: All operational tags placed on this power system resource.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PowerSystemResource.OperationalTags
    multivalued: true
    alias: operational_tags
    owner: RegisteredGenerator
    domain_of:
    - PowerSystemResource
    - Asset
    range: OperationalTag
    required: false
  alias_name:
    name: alias_name
    description: "The aliasName is free text human readable name of the object alternative\
      \ to IdentifiedObject.name. It may be non unique and may not correlate to a\
      \ naming hierarchy.\r\nThe attribute aliasName is retained because of backwards\
      \ compatibility between CIM relases. It is however recommended to replace aliasName\
      \ with the Name class as aliasName is planned for retirement at a future time.\r\
      \n\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.aliasName
    multivalued: false
    alias: alias_name
    owner: RegisteredGenerator
    domain_of:
    - IdentifiedObject
    range: string
    required: false
  description:
    name: description
    description: The description is a free human readable text describing or naming
      the object. It may be non unique and may not correlate to a naming hierarchy.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.description
    multivalued: false
    alias: description
    owner: RegisteredGenerator
    domain_of:
    - IdentifiedObject
    - NameType
    - NameTypeAuthority
    - DataSet
    - SwitchingStepGroup
    - AreaReserveSpec
    range: string
    required: false
  m_rid:
    name: m_rid
    description: "Master resource identifier issued by a model authority. The mRID\
      \ is unique within an exchange context. Global uniqueness is easily achieved\
      \ by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is\
      \ strongly recommended.\r\nFor CIMXML data files in RDF syntax conforming to\
      \ IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify\
      \ CIM object elements."
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.mRID
    multivalued: false
    alias: m_rid
    owner: RegisteredGenerator
    domain_of:
    - IdentifiedObject
    - DataSet
    range: string
    required: false
  diagram_objects:
    name: diagram_objects
    description: The diagram objects that are associated with the domain object.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.DiagramObjects
    multivalued: true
    alias: diagram_objects
    owner: RegisteredGenerator
    domain_of:
    - IdentifiedObject
    range: DiagramObject
    required: false
  instance_set:
    name: instance_set
    description: Dataset containing the data objects.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.InstanceSet
    multivalued: false
    alias: instance_set
    owner: RegisteredGenerator
    domain_of:
    - IdentifiedObject
    range: InstanceSet
    required: true
  names:
    name: names
    description: All names of this identified object.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.Names
    multivalued: true
    alias: names
    owner: RegisteredGenerator
    domain_of:
    - IdentifiedObject
    - NameType
    range: Name
    required: false
  properties_cimdata_object:
    name: properties_cimdata_object
    description: The single CIM data object in the appropriate dataset context.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.PropertiesCIMDataObject
    multivalued: false
    alias: properties_cimdata_object
    owner: RegisteredGenerator
    domain_of:
    - IdentifiedObject
    range: ChangeSetMember
    required: false
  targeting_cimdata_object:
    name: targeting_cimdata_object
    description: Data objects registered.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.TargetingCIMDataObject
    multivalued: true
    alias: targeting_cimdata_object
    owner: RegisteredGenerator
    domain_of:
    - IdentifiedObject
    range: ChangeSetMember
    required: false
class_uri: cim:RegisteredGenerator