Skip to content

Class: ReactiveCapabilityCurve

Reactive power rating envelope versus the synchronous machine's active power, in both the generating and motoring modes. For each active power value there is a corresponding high and low reactive power limit value. Typically there will be a separate curve for each coolant condition, such as hydrogen pressure. The Y1 axis values represent reactive minimum and the Y2 axis values represent reactive maximum.

URI: cim:ReactiveCapabilityCurve

 classDiagram
    class ReactiveCapabilityCurve
      Curve <|-- ReactiveCapabilityCurve

      ReactiveCapabilityCurve : alias_name

      ReactiveCapabilityCurve : coolant_temperature

          ReactiveCapabilityCurve --> Temperature : coolant_temperature

      ReactiveCapabilityCurve : curve_datas

          ReactiveCapabilityCurve --> CurveData : curve_datas

      ReactiveCapabilityCurve : curve_style

          ReactiveCapabilityCurve --> CurveStyle : curve_style

      ReactiveCapabilityCurve : description

      ReactiveCapabilityCurve : diagram_objects

          ReactiveCapabilityCurve --> DiagramObject : diagram_objects

      ReactiveCapabilityCurve : equivalent_injection

          ReactiveCapabilityCurve --> EquivalentInjection : equivalent_injection

      ReactiveCapabilityCurve : hydrogen_pressure

          ReactiveCapabilityCurve --> Pressure : hydrogen_pressure

      ReactiveCapabilityCurve : initially_used_by_synchronous_machines

          ReactiveCapabilityCurve --> SynchronousMachine : initially_used_by_synchronous_machines

      ReactiveCapabilityCurve : instance_set

          ReactiveCapabilityCurve --> InstanceSet : instance_set

      ReactiveCapabilityCurve : m_rid

      ReactiveCapabilityCurve : names

          ReactiveCapabilityCurve --> Name : names

      ReactiveCapabilityCurve : properties_cimdata_object

          ReactiveCapabilityCurve --> ChangeSetMember : properties_cimdata_object

      ReactiveCapabilityCurve : synchronous_machines

          ReactiveCapabilityCurve --> SynchronousMachine : synchronous_machines

      ReactiveCapabilityCurve : targeting_cimdata_object

          ReactiveCapabilityCurve --> ChangeSetMember : targeting_cimdata_object

      ReactiveCapabilityCurve : x_multiplier

          ReactiveCapabilityCurve --> UnitMultiplier : x_multiplier

      ReactiveCapabilityCurve : x_unit

          ReactiveCapabilityCurve --> UnitSymbol : x_unit

      ReactiveCapabilityCurve : y_multiplier

          ReactiveCapabilityCurve --> UnitMultiplier : y_multiplier

      ReactiveCapabilityCurve : y_unit

          ReactiveCapabilityCurve --> UnitSymbol : y_unit

Inheritance

Slots

Name Cardinality and Range Description Inheritance
coolant_temperature 0..1
Temperature
The machine's coolant temperature (e direct
hydrogen_pressure 0..1
Pressure
The hydrogen coolant pressure direct
equivalent_injection 0..*
EquivalentInjection
The equivalent injection using this reactive capability curve direct
initially_used_by_synchronous_machines 1..*
SynchronousMachine
Synchronous machines using this curve as default direct
synchronous_machines 1..*
SynchronousMachine
Synchronous machines using this curve direct
curve_style 0..1
CurveStyle
The style or shape of the curve Curve
x_multiplier 0..1
UnitMultiplier
Multiplier for X-axis Curve
x_unit 0..1
UnitSymbol
The X-axis units of measure Curve
y_multiplier 0..1
UnitMultiplier
Multiplier for Y3-axis Curve
y_unit 0..1
UnitSymbol
The Y3-axis units of measure Curve
curve_datas 0..*
CurveData
The point data values that define this curve Curve
alias_name 0..1
String
The aliasName is free text human readable name of the object alternative to I... IdentifiedObject
description 0..1
String
The description is a free human readable text describing or naming the object IdentifiedObject
m_rid 0..1
String
Master resource identifier issued by a model authority IdentifiedObject
diagram_objects 0..*
DiagramObject
The diagram objects that are associated with the domain object IdentifiedObject
instance_set 1..1
InstanceSet
Dataset containing the data objects IdentifiedObject
names 0..*
Name
All names of this identified object IdentifiedObject
properties_cimdata_object 0..1
ChangeSetMember
The single CIM data object in the appropriate dataset context IdentifiedObject
targeting_cimdata_object 0..*
ChangeSetMember
Data objects registered IdentifiedObject

Usages

used by used in type used
SynchronousMachine initial_reactive_capability_curve range ReactiveCapabilityCurve
SynchronousMachine reactive_capability_curves range ReactiveCapabilityCurve
EquivalentInjection reactive_capability_curve range ReactiveCapabilityCurve

Identifier and Mapping Information

Schema Source

  • from schema: https://cim.ucaiug.io/ns#TC57CIM

Mappings

Mapping Type Mapped Value
self cim:ReactiveCapabilityCurve
native cim:ReactiveCapabilityCurve

LinkML Source

Direct

name: ReactiveCapabilityCurve
description: Reactive power rating envelope versus the synchronous machine's active
  power, in both the generating and motoring modes. For each active power value there
  is a corresponding high and low reactive power limit  value. Typically there will
  be a separate curve for each coolant condition, such as hydrogen pressure.  The
  Y1 axis values represent reactive minimum and the Y2 axis values represent reactive
  maximum.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
is_a: Curve
attributes:
  coolant_temperature:
    name: coolant_temperature
    description: The machine's coolant temperature (e.g., ambient air or stator circulating
      water).
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:ReactiveCapabilityCurve.coolantTemperature
    multivalued: false
    domain_of:
    - ReactiveCapabilityCurve
    range: Temperature
    required: false
  hydrogen_pressure:
    name: hydrogen_pressure
    description: The hydrogen coolant pressure.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:ReactiveCapabilityCurve.hydrogenPressure
    multivalued: false
    domain_of:
    - ReactiveCapabilityCurve
    range: Pressure
    required: false
  equivalent_injection:
    name: equivalent_injection
    description: The equivalent injection using this reactive capability curve.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:ReactiveCapabilityCurve.EquivalentInjection
    multivalued: true
    domain_of:
    - ReactiveCapabilityCurve
    range: EquivalentInjection
    required: false
  initially_used_by_synchronous_machines:
    name: initially_used_by_synchronous_machines
    description: Synchronous machines using this curve as default.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:ReactiveCapabilityCurve.InitiallyUsedBySynchronousMachines
    multivalued: true
    domain_of:
    - ReactiveCapabilityCurve
    range: SynchronousMachine
    required: true
  synchronous_machines:
    name: synchronous_machines
    description: Synchronous machines using this curve.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:ReactiveCapabilityCurve.SynchronousMachines
    multivalued: true
    domain_of:
    - PrimeMover
    - ReactiveCapabilityCurve
    range: SynchronousMachine
    required: true
class_uri: cim:ReactiveCapabilityCurve

Induced

name: ReactiveCapabilityCurve
description: Reactive power rating envelope versus the synchronous machine's active
  power, in both the generating and motoring modes. For each active power value there
  is a corresponding high and low reactive power limit  value. Typically there will
  be a separate curve for each coolant condition, such as hydrogen pressure.  The
  Y1 axis values represent reactive minimum and the Y2 axis values represent reactive
  maximum.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
is_a: Curve
attributes:
  coolant_temperature:
    name: coolant_temperature
    description: The machine's coolant temperature (e.g., ambient air or stator circulating
      water).
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:ReactiveCapabilityCurve.coolantTemperature
    multivalued: false
    alias: coolant_temperature
    owner: ReactiveCapabilityCurve
    domain_of:
    - ReactiveCapabilityCurve
    range: Temperature
    required: false
  hydrogen_pressure:
    name: hydrogen_pressure
    description: The hydrogen coolant pressure.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:ReactiveCapabilityCurve.hydrogenPressure
    multivalued: false
    alias: hydrogen_pressure
    owner: ReactiveCapabilityCurve
    domain_of:
    - ReactiveCapabilityCurve
    range: Pressure
    required: false
  equivalent_injection:
    name: equivalent_injection
    description: The equivalent injection using this reactive capability curve.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:ReactiveCapabilityCurve.EquivalentInjection
    multivalued: true
    alias: equivalent_injection
    owner: ReactiveCapabilityCurve
    domain_of:
    - ReactiveCapabilityCurve
    range: EquivalentInjection
    required: false
  initially_used_by_synchronous_machines:
    name: initially_used_by_synchronous_machines
    description: Synchronous machines using this curve as default.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:ReactiveCapabilityCurve.InitiallyUsedBySynchronousMachines
    multivalued: true
    alias: initially_used_by_synchronous_machines
    owner: ReactiveCapabilityCurve
    domain_of:
    - ReactiveCapabilityCurve
    range: SynchronousMachine
    required: true
  synchronous_machines:
    name: synchronous_machines
    description: Synchronous machines using this curve.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:ReactiveCapabilityCurve.SynchronousMachines
    multivalued: true
    alias: synchronous_machines
    owner: ReactiveCapabilityCurve
    domain_of:
    - PrimeMover
    - ReactiveCapabilityCurve
    range: SynchronousMachine
    required: true
  curve_style:
    name: curve_style
    description: The style or shape of the curve.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Curve.curveStyle
    multivalued: false
    alias: curve_style
    owner: ReactiveCapabilityCurve
    domain_of:
    - Curve
    range: CurveStyle
    required: false
  x_multiplier:
    name: x_multiplier
    description: Multiplier for X-axis.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Curve.xMultiplier
    multivalued: false
    alias: x_multiplier
    owner: ReactiveCapabilityCurve
    domain_of:
    - Curve
    range: UnitMultiplier
    required: false
  x_unit:
    name: x_unit
    description: The X-axis units of measure.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Curve.xUnit
    multivalued: false
    alias: x_unit
    owner: ReactiveCapabilityCurve
    domain_of:
    - Curve
    range: UnitSymbol
    required: false
  y_multiplier:
    name: y_multiplier
    description: Multiplier for Y3-axis.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Curve.y3Multiplier
    multivalued: false
    alias: y_multiplier
    owner: ReactiveCapabilityCurve
    domain_of:
    - Curve
    - DERMonitorableParameter
    range: UnitMultiplier
    required: false
  y_unit:
    name: y_unit
    description: The Y3-axis units of measure.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Curve.y3Unit
    multivalued: false
    alias: y_unit
    owner: ReactiveCapabilityCurve
    domain_of:
    - Curve
    - DERMonitorableParameter
    range: UnitSymbol
    required: false
  curve_datas:
    name: curve_datas
    description: The point data values that define this curve.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Curve.CurveDatas
    multivalued: true
    alias: curve_datas
    owner: ReactiveCapabilityCurve
    domain_of:
    - Curve
    range: CurveData
    required: false
  alias_name:
    name: alias_name
    description: "The aliasName is free text human readable name of the object alternative\
      \ to IdentifiedObject.name. It may be non unique and may not correlate to a\
      \ naming hierarchy.\r\nThe attribute aliasName is retained because of backwards\
      \ compatibility between CIM relases. It is however recommended to replace aliasName\
      \ with the Name class as aliasName is planned for retirement at a future time.\r\
      \n\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.aliasName
    multivalued: false
    alias: alias_name
    owner: ReactiveCapabilityCurve
    domain_of:
    - IdentifiedObject
    range: string
    required: false
  description:
    name: description
    description: The description is a free human readable text describing or naming
      the object. It may be non unique and may not correlate to a naming hierarchy.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.description
    multivalued: false
    alias: description
    owner: ReactiveCapabilityCurve
    domain_of:
    - IdentifiedObject
    - NameType
    - NameTypeAuthority
    - DataSet
    - SwitchingStepGroup
    - AreaReserveSpec
    range: string
    required: false
  m_rid:
    name: m_rid
    description: "Master resource identifier issued by a model authority. The mRID\
      \ is unique within an exchange context. Global uniqueness is easily achieved\
      \ by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is\
      \ strongly recommended.\r\nFor CIMXML data files in RDF syntax conforming to\
      \ IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify\
      \ CIM object elements."
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.mRID
    multivalued: false
    alias: m_rid
    owner: ReactiveCapabilityCurve
    domain_of:
    - IdentifiedObject
    - DataSet
    range: string
    required: false
  diagram_objects:
    name: diagram_objects
    description: The diagram objects that are associated with the domain object.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.DiagramObjects
    multivalued: true
    alias: diagram_objects
    owner: ReactiveCapabilityCurve
    domain_of:
    - IdentifiedObject
    range: DiagramObject
    required: false
  instance_set:
    name: instance_set
    description: Dataset containing the data objects.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.InstanceSet
    multivalued: false
    alias: instance_set
    owner: ReactiveCapabilityCurve
    domain_of:
    - IdentifiedObject
    range: InstanceSet
    required: true
  names:
    name: names
    description: All names of this identified object.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.Names
    multivalued: true
    alias: names
    owner: ReactiveCapabilityCurve
    domain_of:
    - IdentifiedObject
    - NameType
    range: Name
    required: false
  properties_cimdata_object:
    name: properties_cimdata_object
    description: The single CIM data object in the appropriate dataset context.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.PropertiesCIMDataObject
    multivalued: false
    alias: properties_cimdata_object
    owner: ReactiveCapabilityCurve
    domain_of:
    - IdentifiedObject
    range: ChangeSetMember
    required: false
  targeting_cimdata_object:
    name: targeting_cimdata_object
    description: Data objects registered.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.TargetingCIMDataObject
    multivalued: true
    alias: targeting_cimdata_object
    owner: ReactiveCapabilityCurve
    domain_of:
    - IdentifiedObject
    range: ChangeSetMember
    required: false
class_uri: cim:ReactiveCapabilityCurve