Class: PotentialTransformer
Instrument transformer (also known as Voltage Transformer) used to measure electrical qualities of the circuit that is being protected and/or monitored. Typically used as voltage transducer for the purpose of metering, protection, or sometimes auxiliary substation supply. A typical secondary voltage rating would be 120V.
classDiagram
class PotentialTransformer
Sensor <|-- PotentialTransformer
PotentialTransformer : accuracy_class
PotentialTransformer : additional_equipment_container
PotentialTransformer --> EquipmentContainer : additional_equipment_container
PotentialTransformer : aggregate
PotentialTransformer : alias_name
PotentialTransformer : asset_datasheet
PotentialTransformer --> AssetInfo : asset_datasheet
PotentialTransformer : assets
PotentialTransformer --> Asset : assets
PotentialTransformer : clearances
PotentialTransformer --> ClearanceDocument : clearances
PotentialTransformer : configuration_event
PotentialTransformer --> ConfigurationEvent : configuration_event
PotentialTransformer : contingency_equipment
PotentialTransformer --> ContingencyEquipment : contingency_equipment
PotentialTransformer : controls
PotentialTransformer --> Control : controls
PotentialTransformer : description
PotentialTransformer : diagram_objects
PotentialTransformer --> DiagramObject : diagram_objects
PotentialTransformer : eqiupment_limit_series_component
PotentialTransformer --> EquipmentLimitSeriesComponent : eqiupment_limit_series_component
PotentialTransformer : equipment_container
PotentialTransformer --> EquipmentContainer : equipment_container
PotentialTransformer : equipment_unavailability_schedule
PotentialTransformer --> EquipmentUnavailabilitySchedule : equipment_unavailability_schedule
PotentialTransformer : faults
PotentialTransformer --> Fault : faults
PotentialTransformer : generic_action
PotentialTransformer --> GenericAction : generic_action
PotentialTransformer : in_service
PotentialTransformer : instance_set
PotentialTransformer --> InstanceSet : instance_set
PotentialTransformer : limit_dependency_model
PotentialTransformer --> LimitDependency : limit_dependency_model
PotentialTransformer : location
PotentialTransformer --> Location : location
PotentialTransformer : m_rid
PotentialTransformer : measurements
PotentialTransformer --> Measurement : measurements
PotentialTransformer : names
PotentialTransformer --> Name : names
PotentialTransformer : network_analysis_enabled
PotentialTransformer : nominal_ratio
PotentialTransformer : normally_in_service
PotentialTransformer : operating_share
PotentialTransformer --> OperatingShare : operating_share
PotentialTransformer : operational_limit_set
PotentialTransformer --> OperationalLimitSet : operational_limit_set
PotentialTransformer : operational_restrictions
PotentialTransformer --> OperationalRestriction : operational_restrictions
PotentialTransformer : operational_tags
PotentialTransformer --> OperationalTag : operational_tags
PotentialTransformer : outages
PotentialTransformer --> Outage : outages
PotentialTransformer : pin_equipment
PotentialTransformer --> PinEquipment : pin_equipment
PotentialTransformer : properties_cimdata_object
PotentialTransformer --> ChangeSetMember : properties_cimdata_object
PotentialTransformer : protective_action_equipment
PotentialTransformer --> ProtectiveActionEquipment : protective_action_equipment
PotentialTransformer : psrevents
PotentialTransformer --> PSREvent : psrevents
PotentialTransformer : psrtype
PotentialTransformer --> PSRType : psrtype
PotentialTransformer : pt_class
PotentialTransformer : reporting_group
PotentialTransformer --> ReportingGroup : reporting_group
PotentialTransformer : targeting_cimdata_object
PotentialTransformer --> ChangeSetMember : targeting_cimdata_object
PotentialTransformer : terminal
PotentialTransformer --> Terminal : terminal
PotentialTransformer : type
PotentialTransformer --> PotentialTransformerKind : type
PotentialTransformer : usage_points
PotentialTransformer --> UsagePoint : usage_points
PotentialTransformer : verification_action
PotentialTransformer --> VerificationAction : verification_action
PotentialTransformer : weather_station
PotentialTransformer --> WeatherStation : weather_station
Inheritance
- IdentifiedObject
- PowerSystemResource
- Equipment
- AuxiliaryEquipment
- Sensor
- PotentialTransformer
- Sensor
- AuxiliaryEquipment
- Equipment
- PowerSystemResource
Slots
| Name | Cardinality and Range | Description | Inheritance |
|---|---|---|---|
| accuracy_class | 0..1 String |
PT accuracy classification | direct |
| nominal_ratio | 0..1 Float |
Nominal ratio between the primary and secondary voltage | direct |
| pt_class | 0..1 String |
Potential transformer (PT) classification covering burden | direct |
| type | 0..1 PotentialTransformerKind |
Potential transformer construction type | direct |
| terminal | 1..1 Terminal |
The Terminal at the equipment where the AuxiliaryEquipment is attached | AuxiliaryEquipment |
| aggregate | 0..1 Boolean |
The aggregate flag provides an alternative way of representing an aggregated ... | Equipment |
| in_service | 0..1 Boolean |
Specifies the availability of the equipment | Equipment |
| network_analysis_enabled | 0..1 Boolean |
The equipment is enabled to participate in network analysis | Equipment |
| normally_in_service | 0..1 Boolean |
Specifies the availability of the equipment under normal operating conditions | Equipment |
| weather_station | 0..* WeatherStation |
Equipment | |
| operational_limit_set | 0..* OperationalLimitSet |
The operational limit sets associated with this equipment | Equipment |
| contingency_equipment | 0..* ContingencyEquipment |
The contingency equipments in which this equipment participates | Equipment |
| equipment_container | 0..1 EquipmentContainer |
Container of this equipment | Equipment |
| faults | 0..* Fault |
All faults on this equipment | Equipment |
| limit_dependency_model | 0..* LimitDependency |
Limit dependencymodels organized under this equipment as a means for organizi... | Equipment |
| eqiupment_limit_series_component | 0..* EquipmentLimitSeriesComponent |
Equipment limit series calculation component to which this equipment contribu... | Equipment |
| protective_action_equipment | 0..* ProtectiveActionEquipment |
Protective action is controlling equipment | Equipment |
| pin_equipment | 0..* PinEquipment |
Equipment | |
| equipment_unavailability_schedule | 0..* EquipmentUnavailabilitySchedule |
Equipment | |
| additional_equipment_container | 0..* EquipmentContainer |
Additional equipment container beyond the primary equipment container | Equipment |
| usage_points | 0..* UsagePoint |
All usage points connected to the electrical grid through this equipment | Equipment |
| outages | 0..* Outage |
All outages in which this equipment is involved | Equipment |
| operational_restrictions | 0..* OperationalRestriction |
All operational restrictions for this equipment | Equipment |
| controls | 0..* Control |
The controller outputs used to actually govern a regulating device, e | PowerSystemResource |
| measurements | 0..* Measurement |
The measurements associated with this power system resource | PowerSystemResource |
| psrtype | 0..1 PSRType |
Custom classification for this power system resource | PowerSystemResource |
| configuration_event | 0..* ConfigurationEvent |
All configuration events created for this Power System resource | PowerSystemResource |
| reporting_group | 0..* ReportingGroup |
Reporting groups to which this power system resource belongs | PowerSystemResource |
| operating_share | 0..* OperatingShare |
The operating shares of this power system resource | PowerSystemResource |
| asset_datasheet | 0..1 AssetInfo |
Datasheet information for this power system resource | PowerSystemResource |
| verification_action | 0..* VerificationAction |
The verification action that is performed on the power system resource | PowerSystemResource |
| clearances | 0..* ClearanceDocument |
All clearances applicable to this power system resource | PowerSystemResource |
| generic_action | 0..* GenericAction |
The generic action that is performed on the power system resource | PowerSystemResource |
| psrevents | 0..* PSREvent |
All events associated with this power system resource | PowerSystemResource |
| assets | 0..* Asset |
All assets represented by this power system resource | PowerSystemResource |
| location | 0..1 Location |
Location of this power system resource | PowerSystemResource |
| operational_tags | 0..* OperationalTag |
All operational tags placed on this power system resource | PowerSystemResource |
| alias_name | 0..1 String |
The aliasName is free text human readable name of the object alternative to I... | IdentifiedObject |
| description | 0..1 String |
The description is a free human readable text describing or naming the object | IdentifiedObject |
| m_rid | 0..1 String |
Master resource identifier issued by a model authority | IdentifiedObject |
| diagram_objects | 0..* DiagramObject |
The diagram objects that are associated with the domain object | IdentifiedObject |
| instance_set | 1..1 InstanceSet |
Dataset containing the data objects | IdentifiedObject |
| names | 0..* Name |
All names of this identified object | IdentifiedObject |
| properties_cimdata_object | 0..1 ChangeSetMember |
The single CIM data object in the appropriate dataset context | IdentifiedObject |
| targeting_cimdata_object | 0..* ChangeSetMember |
Data objects registered | IdentifiedObject |
Identifier and Mapping Information
Schema Source
- from schema: https://cim.ucaiug.io/ns#TC57CIM
Mappings
| Mapping Type | Mapped Value |
|---|---|
| self | cim:PotentialTransformer |
| native | cim:PotentialTransformer |
LinkML Source
Direct
name: PotentialTransformer
description: Instrument transformer (also known as Voltage Transformer) used to measure
electrical qualities of the circuit that is being protected and/or monitored. Typically
used as voltage transducer for the purpose of metering, protection, or sometimes
auxiliary substation supply. A typical secondary voltage rating would be 120V.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
is_a: Sensor
attributes:
accuracy_class:
name: accuracy_class
description: PT accuracy classification.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:PotentialTransformer.accuracyClass
multivalued: false
domain_of:
- CurrentTransformer
- PotentialTransformer
- CurrentTransformerInfo
- PotentialTransformerInfo
range: string
required: false
nominal_ratio:
name: nominal_ratio
description: Nominal ratio between the primary and secondary voltage.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PotentialTransformer.nominalRatio
multivalued: false
domain_of:
- PotentialTransformer
- CurrentTransformerInfo
- PotentialTransformerInfo
range: float
required: false
pt_class:
name: pt_class
description: Potential transformer (PT) classification covering burden.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PotentialTransformer.ptClass
multivalued: false
domain_of:
- PotentialTransformer
- PotentialTransformerInfo
range: string
required: false
type:
name: type
description: Potential transformer construction type.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:PotentialTransformer.type
multivalued: false
domain_of:
- Asset
- AcceptanceTest
- Document
- StreetDetail
- Location
- Priority
- CatalogAssetType
- Capability
- Craft
- OldPerson
- Role
- ActivityRecord
- EndDeviceEventType
- EndDeviceGroup
- DemandResponseProgram
- UsagePointGroup
- EndDeviceControlType
- Hazard
- OldCrew
- Route
- ConstraintDuration
- AceTariffType
- ControlArea
- SynchronousMachine
- ChargeProfile
- ChargeComponent
- MarketRole
- ResourceGroup
- Quantity
- ResourceCertification
- Auction
- ScheduledEvent
- PotentialTransformer
- BusinessRole
range: PotentialTransformerKind
required: false
class_uri: cim:PotentialTransformer
Induced
name: PotentialTransformer
description: Instrument transformer (also known as Voltage Transformer) used to measure
electrical qualities of the circuit that is being protected and/or monitored. Typically
used as voltage transducer for the purpose of metering, protection, or sometimes
auxiliary substation supply. A typical secondary voltage rating would be 120V.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
is_a: Sensor
attributes:
accuracy_class:
name: accuracy_class
description: PT accuracy classification.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:PotentialTransformer.accuracyClass
multivalued: false
alias: accuracy_class
owner: PotentialTransformer
domain_of:
- CurrentTransformer
- PotentialTransformer
- CurrentTransformerInfo
- PotentialTransformerInfo
range: string
required: false
nominal_ratio:
name: nominal_ratio
description: Nominal ratio between the primary and secondary voltage.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PotentialTransformer.nominalRatio
multivalued: false
alias: nominal_ratio
owner: PotentialTransformer
domain_of:
- PotentialTransformer
- CurrentTransformerInfo
- PotentialTransformerInfo
range: float
required: false
pt_class:
name: pt_class
description: Potential transformer (PT) classification covering burden.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PotentialTransformer.ptClass
multivalued: false
alias: pt_class
owner: PotentialTransformer
domain_of:
- PotentialTransformer
- PotentialTransformerInfo
range: string
required: false
type:
name: type
description: Potential transformer construction type.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:PotentialTransformer.type
multivalued: false
alias: type
owner: PotentialTransformer
domain_of:
- Asset
- AcceptanceTest
- Document
- StreetDetail
- Location
- Priority
- CatalogAssetType
- Capability
- Craft
- OldPerson
- Role
- ActivityRecord
- EndDeviceEventType
- EndDeviceGroup
- DemandResponseProgram
- UsagePointGroup
- EndDeviceControlType
- Hazard
- OldCrew
- Route
- ConstraintDuration
- AceTariffType
- ControlArea
- SynchronousMachine
- ChargeProfile
- ChargeComponent
- MarketRole
- ResourceGroup
- Quantity
- ResourceCertification
- Auction
- ScheduledEvent
- PotentialTransformer
- BusinessRole
range: PotentialTransformerKind
required: false
terminal:
name: terminal
description: The Terminal at the equipment where the AuxiliaryEquipment is attached.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:AuxiliaryEquipment.Terminal
multivalued: false
alias: terminal
owner: PotentialTransformer
domain_of:
- BusNameMarker
- OperationalLimitSet
- TopologicalNode
- TransformerEnd
- Measurement
- Bushing
- TieFlow
- SvPowerFlow
- RegulatingControl
- RemoteInputSignal
- BranchGroupTerminal
- AuxiliaryEquipment
- EquipmentFault
- PinTerminal
range: Terminal
required: true
aggregate:
name: aggregate
description: "The aggregate flag provides an alternative way of representing an\
\ aggregated (equivalent) element. It is applicable in cases when the dedicated\
\ classes for equivalent equipment do not have all of the attributes necessary\
\ to represent the required level of detail. In case the flag is set to “true”\
\ the single instance of equipment represents multiple pieces of equipment that\
\ have been modelled together as an aggregate equivalent obtained by a network\
\ reduction procedure. Examples would be power transformers or synchronous machines\
\ operating in parallel modelled as a single aggregate power transformer or\
\ aggregate synchronous machine. \r\nThe attribute is not used for EquivalentBranch,\
\ EquivalentShunt and EquivalentInjection."
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.aggregate
multivalued: false
alias: aggregate
owner: PotentialTransformer
domain_of:
- Equipment
- ReadingType
range: boolean
required: false
in_service:
name: in_service
description: Specifies the availability of the equipment. True means the equipment
is available for topology processing, which determines if the equipment is energized
or not. False means that the equipment is treated by network applications as
if it is not in the model.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.inService
multivalued: false
alias: in_service
owner: PotentialTransformer
domain_of:
- Equipment
- SvStatus
- ProtectiveActionEquipment
range: boolean
required: false
network_analysis_enabled:
name: network_analysis_enabled
description: The equipment is enabled to participate in network analysis. If
unspecified, the value is assumed to be true.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.networkAnalysisEnabled
multivalued: false
alias: network_analysis_enabled
owner: PotentialTransformer
domain_of:
- Equipment
range: boolean
required: false
normally_in_service:
name: normally_in_service
description: Specifies the availability of the equipment under normal operating
conditions. True means the equipment is available for topology processing, which
determines if the equipment is energized or not. False means that the equipment
is treated by network applications as if it is not in the model.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.normallyInService
multivalued: false
alias: normally_in_service
owner: PotentialTransformer
domain_of:
- Equipment
range: boolean
required: false
weather_station:
name: weather_station
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.WeatherStation
multivalued: true
alias: weather_station
owner: PotentialTransformer
domain_of:
- Equipment
range: WeatherStation
required: false
operational_limit_set:
name: operational_limit_set
description: The operational limit sets associated with this equipment.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:Equipment.OperationalLimitSet
multivalued: true
alias: operational_limit_set
owner: PotentialTransformer
domain_of:
- ACDCTerminal
- OperationalLimit
- Equipment
range: OperationalLimitSet
required: false
contingency_equipment:
name: contingency_equipment
description: The contingency equipments in which this equipment participates.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.ContingencyEquipment
multivalued: true
alias: contingency_equipment
owner: PotentialTransformer
domain_of:
- Equipment
range: ContingencyEquipment
required: false
equipment_container:
name: equipment_container
description: Container of this equipment.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.EquipmentContainer
multivalued: false
alias: equipment_container
owner: PotentialTransformer
domain_of:
- Equipment
range: EquipmentContainer
required: false
faults:
name: faults
description: All faults on this equipment.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.Faults
multivalued: true
alias: faults
owner: PotentialTransformer
domain_of:
- Equipment
- Outage
- FaultCauseType
range: Fault
required: false
limit_dependency_model:
name: limit_dependency_model
description: Limit dependencymodels organized under this equipment as a means
for organizing the model in a tree view.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:Equipment.LimitDependencyModel
multivalued: true
alias: limit_dependency_model
owner: PotentialTransformer
domain_of:
- OperationalLimit
- Equipment
range: LimitDependency
required: false
eqiupment_limit_series_component:
name: eqiupment_limit_series_component
description: Equipment limit series calculation component to which this equipment
contributes.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.EqiupmentLimitSeriesComponent
multivalued: true
alias: eqiupment_limit_series_component
owner: PotentialTransformer
domain_of:
- Equipment
range: EquipmentLimitSeriesComponent
required: false
protective_action_equipment:
name: protective_action_equipment
description: Protective action is controlling equipment. This can be direct signals
from the control center, or emulation of action done by protection equipment.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.ProtectiveActionEquipment
multivalued: true
alias: protective_action_equipment
owner: PotentialTransformer
domain_of:
- Equipment
range: ProtectiveActionEquipment
required: false
pin_equipment:
name: pin_equipment
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.PinEquipment
multivalued: true
alias: pin_equipment
owner: PotentialTransformer
domain_of:
- Equipment
range: PinEquipment
required: false
equipment_unavailability_schedule:
name: equipment_unavailability_schedule
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.EquipmentUnavailabilitySchedule
multivalued: true
alias: equipment_unavailability_schedule
owner: PotentialTransformer
domain_of:
- Equipment
- UnavailabilitySwitchAction
- UnavailablitySchedule
range: EquipmentUnavailabilitySchedule
required: false
additional_equipment_container:
name: additional_equipment_container
description: Additional equipment container beyond the primary equipment container. The
equipment is contained in another equipment container, but also grouped with
this equipment container.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.AdditionalEquipmentContainer
multivalued: true
alias: additional_equipment_container
owner: PotentialTransformer
domain_of:
- Equipment
range: EquipmentContainer
required: false
usage_points:
name: usage_points
description: All usage points connected to the electrical grid through this equipment.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.UsagePoints
multivalued: true
alias: usage_points
owner: PotentialTransformer
domain_of:
- Equipment
- CustomerAgreement
- ServiceCategory
- PricingStructure
- EndDeviceControl
- UsagePointGroup
- ServiceLocation
- MetrologyRequirement
- ServiceSupplier
- UsagePointLocation
range: UsagePoint
required: false
outages:
name: outages
description: All outages in which this equipment is involved.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.Outages
multivalued: true
alias: outages
owner: PotentialTransformer
domain_of:
- Equipment
range: Outage
required: false
operational_restrictions:
name: operational_restrictions
description: All operational restrictions for this equipment.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.OperationalRestrictions
multivalued: true
alias: operational_restrictions
owner: PotentialTransformer
domain_of:
- Equipment
- ProductAssetModel
range: OperationalRestriction
required: false
controls:
name: controls
description: The controller outputs used to actually govern a regulating device,
e.g. the magnetization of a synchronous machine or capacitor bank breaker actuator.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.Controls
multivalued: true
alias: controls
owner: PotentialTransformer
domain_of:
- PowerSystemResource
- HostControlArea
range: Control
required: false
measurements:
name: measurements
description: The measurements associated with this power system resource.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.Measurements
multivalued: true
alias: measurements
owner: PotentialTransformer
domain_of:
- PowerSystemResource
- ACDCTerminal
- Asset
- Location
- Procedure
- AnalogLimitSet
- AccumulatorLimitSet
range: Measurement
required: false
psrtype:
name: psrtype
description: Custom classification for this power system resource.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.PSRType
multivalued: false
alias: psrtype
owner: PotentialTransformer
domain_of:
- PowerSystemResource
range: PSRType
required: false
configuration_event:
name: configuration_event
description: All configuration events created for this Power System resource.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.ConfigurationEvent
multivalued: true
alias: configuration_event
owner: PotentialTransformer
domain_of:
- PowerSystemResource
- FaultCauseType
range: ConfigurationEvent
required: false
reporting_group:
name: reporting_group
description: Reporting groups to which this power system resource belongs.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.ReportingGroup
multivalued: true
alias: reporting_group
owner: PotentialTransformer
domain_of:
- PowerSystemResource
- BusNameMarker
- TopologicalNode
- ReportingSuperGroup
range: ReportingGroup
required: false
operating_share:
name: operating_share
description: The operating shares of this power system resource.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.OperatingShare
multivalued: true
alias: operating_share
owner: PotentialTransformer
domain_of:
- PowerSystemResource
- OperatingParticipant
range: OperatingShare
required: false
asset_datasheet:
name: asset_datasheet
description: Datasheet information for this power system resource.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.AssetDatasheet
multivalued: false
alias: asset_datasheet
owner: PotentialTransformer
domain_of:
- PowerSystemResource
range: AssetInfo
required: false
verification_action:
name: verification_action
description: The verification action that is performed on the power system resource
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.VerificationAction
multivalued: true
alias: verification_action
owner: PotentialTransformer
domain_of:
- PowerSystemResource
range: VerificationAction
required: false
clearances:
name: clearances
description: All clearances applicable to this power system resource.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.Clearances
multivalued: true
alias: clearances
owner: PotentialTransformer
domain_of:
- PowerSystemResource
range: ClearanceDocument
required: false
generic_action:
name: generic_action
description: The generic action that is performed on the power system resource
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.GenericAction
multivalued: true
alias: generic_action
owner: PotentialTransformer
domain_of:
- PowerSystemResource
range: GenericAction
required: false
psrevents:
name: psrevents
description: All events associated with this power system resource.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.PSREvents
multivalued: true
alias: psrevents
owner: PotentialTransformer
domain_of:
- PowerSystemResource
range: PSREvent
required: false
assets:
name: assets
description: All assets represented by this power system resource. For example,
multiple conductor assets are electrically modelled as a single AC line segment.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.Assets
multivalued: true
alias: assets
owner: PotentialTransformer
domain_of:
- PowerSystemResource
- AssetInfo
- Location
- WorkTask
- ErpRecDelvLineItem
- AssetContainer
- ActivityRecord
- Procedure
- ReliabilityInfo
- AssetPropertyCurve
- AssetOrganisationRole
- ScheduledEvent
range: Asset
required: false
location:
name: location
description: Location of this power system resource.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.Location
multivalued: false
alias: location
owner: PotentialTransformer
domain_of:
- PowerSystemResource
- Asset
- Incident
- SwitchingOrder
- TroubleOrder
- Crew
- Fault
- PointOfSale
- TroubleTicket
- OutageOrder
- EnvironmentalMonitoringStation
- EnvironmentalLocationType
- PositionPoint
- FailureEvent
range: Location
required: false
operational_tags:
name: operational_tags
description: All operational tags placed on this power system resource.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.OperationalTags
multivalued: true
alias: operational_tags
owner: PotentialTransformer
domain_of:
- PowerSystemResource
- Asset
range: OperationalTag
required: false
alias_name:
name: alias_name
description: "The aliasName is free text human readable name of the object alternative\
\ to IdentifiedObject.name. It may be non unique and may not correlate to a\
\ naming hierarchy.\r\nThe attribute aliasName is retained because of backwards\
\ compatibility between CIM relases. It is however recommended to replace aliasName\
\ with the Name class as aliasName is planned for retirement at a future time.\r\
\n\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.aliasName
multivalued: false
alias: alias_name
owner: PotentialTransformer
domain_of:
- IdentifiedObject
range: string
required: false
description:
name: description
description: The description is a free human readable text describing or naming
the object. It may be non unique and may not correlate to a naming hierarchy.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.description
multivalued: false
alias: description
owner: PotentialTransformer
domain_of:
- IdentifiedObject
- NameType
- NameTypeAuthority
- DataSet
- SwitchingStepGroup
- AreaReserveSpec
range: string
required: false
m_rid:
name: m_rid
description: "Master resource identifier issued by a model authority. The mRID\
\ is unique within an exchange context. Global uniqueness is easily achieved\
\ by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is\
\ strongly recommended.\r\nFor CIMXML data files in RDF syntax conforming to\
\ IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify\
\ CIM object elements."
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.mRID
multivalued: false
alias: m_rid
owner: PotentialTransformer
domain_of:
- IdentifiedObject
- DataSet
range: string
required: false
diagram_objects:
name: diagram_objects
description: The diagram objects that are associated with the domain object.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.DiagramObjects
multivalued: true
alias: diagram_objects
owner: PotentialTransformer
domain_of:
- IdentifiedObject
range: DiagramObject
required: false
instance_set:
name: instance_set
description: Dataset containing the data objects.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.InstanceSet
multivalued: false
alias: instance_set
owner: PotentialTransformer
domain_of:
- IdentifiedObject
range: InstanceSet
required: true
names:
name: names
description: All names of this identified object.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.Names
multivalued: true
alias: names
owner: PotentialTransformer
domain_of:
- IdentifiedObject
- NameType
range: Name
required: false
properties_cimdata_object:
name: properties_cimdata_object
description: The single CIM data object in the appropriate dataset context.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.PropertiesCIMDataObject
multivalued: false
alias: properties_cimdata_object
owner: PotentialTransformer
domain_of:
- IdentifiedObject
range: ChangeSetMember
required: false
targeting_cimdata_object:
name: targeting_cimdata_object
description: Data objects registered.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.TargetingCIMDataObject
multivalued: true
alias: targeting_cimdata_object
owner: PotentialTransformer
domain_of:
- IdentifiedObject
range: ChangeSetMember
required: false
class_uri: cim:PotentialTransformer