Skip to content

Class: PetersenCoil

A variable impedance device normally used to offset line charging during single line faults in an ungrounded section of network.

URI: cim:PetersenCoil

 classDiagram
    class PetersenCoil
      EarthFaultCompensator <|-- PetersenCoil

      PetersenCoil : additional_equipment_container

          PetersenCoil --> EquipmentContainer : additional_equipment_container

      PetersenCoil : aggregate

      PetersenCoil : alias_name

      PetersenCoil : asset_datasheet

          PetersenCoil --> AssetInfo : asset_datasheet

      PetersenCoil : assets

          PetersenCoil --> Asset : assets

      PetersenCoil : base_voltage

          PetersenCoil --> BaseVoltage : base_voltage

      PetersenCoil : clearances

          PetersenCoil --> ClearanceDocument : clearances

      PetersenCoil : configuration_event

          PetersenCoil --> ConfigurationEvent : configuration_event

      PetersenCoil : contingency_equipment

          PetersenCoil --> ContingencyEquipment : contingency_equipment

      PetersenCoil : controls

          PetersenCoil --> Control : controls

      PetersenCoil : description

      PetersenCoil : diagram_objects

          PetersenCoil --> DiagramObject : diagram_objects

      PetersenCoil : eqiupment_limit_series_component

          PetersenCoil --> EquipmentLimitSeriesComponent : eqiupment_limit_series_component

      PetersenCoil : equipment_container

          PetersenCoil --> EquipmentContainer : equipment_container

      PetersenCoil : equipment_unavailability_schedule

          PetersenCoil --> EquipmentUnavailabilitySchedule : equipment_unavailability_schedule

      PetersenCoil : faults

          PetersenCoil --> Fault : faults

      PetersenCoil : generic_action

          PetersenCoil --> GenericAction : generic_action

      PetersenCoil : grounding_action

          PetersenCoil --> GroundAction : grounding_action

      PetersenCoil : in_service

      PetersenCoil : instance_set

          PetersenCoil --> InstanceSet : instance_set

      PetersenCoil : jumping_action

          PetersenCoil --> JumperAction : jumping_action

      PetersenCoil : limit_dependency_model

          PetersenCoil --> LimitDependency : limit_dependency_model

      PetersenCoil : location

          PetersenCoil --> Location : location

      PetersenCoil : m_rid

      PetersenCoil : measurements

          PetersenCoil --> Measurement : measurements

      PetersenCoil : mode

          PetersenCoil --> PetersenCoilModeKind : mode

      PetersenCoil : names

          PetersenCoil --> Name : names

      PetersenCoil : network_analysis_enabled

      PetersenCoil : nominal_u

          PetersenCoil --> Voltage : nominal_u

      PetersenCoil : normally_in_service

      PetersenCoil : offset_current

          PetersenCoil --> CurrentFlow : offset_current

      PetersenCoil : operating_share

          PetersenCoil --> OperatingShare : operating_share

      PetersenCoil : operational_limit_set

          PetersenCoil --> OperationalLimitSet : operational_limit_set

      PetersenCoil : operational_restrictions

          PetersenCoil --> OperationalRestriction : operational_restrictions

      PetersenCoil : operational_tags

          PetersenCoil --> OperationalTag : operational_tags

      PetersenCoil : outage

          PetersenCoil --> Outage : outage

      PetersenCoil : outages

          PetersenCoil --> Outage : outages

      PetersenCoil : pin_equipment

          PetersenCoil --> PinEquipment : pin_equipment

      PetersenCoil : position_current

          PetersenCoil --> CurrentFlow : position_current

      PetersenCoil : properties_cimdata_object

          PetersenCoil --> ChangeSetMember : properties_cimdata_object

      PetersenCoil : protection_equipments

          PetersenCoil --> ProtectionEquipment : protection_equipments

      PetersenCoil : protective_action_adjustment

          PetersenCoil --> ProtectiveActionAdjustment : protective_action_adjustment

      PetersenCoil : protective_action_equipment

          PetersenCoil --> ProtectiveActionEquipment : protective_action_equipment

      PetersenCoil : psrevents

          PetersenCoil --> PSREvent : psrevents

      PetersenCoil : psrtype

          PetersenCoil --> PSRType : psrtype

      PetersenCoil : r

          PetersenCoil --> Resistance : r

      PetersenCoil : reporting_group

          PetersenCoil --> ReportingGroup : reporting_group

      PetersenCoil : sv_status

          PetersenCoil --> SvStatus : sv_status

      PetersenCoil : targeting_cimdata_object

          PetersenCoil --> ChangeSetMember : targeting_cimdata_object

      PetersenCoil : terminals

          PetersenCoil --> Terminal : terminals

      PetersenCoil : usage_points

          PetersenCoil --> UsagePoint : usage_points

      PetersenCoil : verification_action

          PetersenCoil --> VerificationAction : verification_action

      PetersenCoil : weather_station

          PetersenCoil --> WeatherStation : weather_station

      PetersenCoil : x_ground_max

          PetersenCoil --> Reactance : x_ground_max

      PetersenCoil : x_ground_min

          PetersenCoil --> Reactance : x_ground_min

      PetersenCoil : x_ground_nominal

          PetersenCoil --> Reactance : x_ground_nominal

Inheritance

Slots

Name Cardinality and Range Description Inheritance
mode 0..1
PetersenCoilModeKind
The mode of operation of the Petersen coil direct
nominal_u 0..1
Voltage
The nominal voltage for which the coil is designed direct
offset_current 0..1
CurrentFlow
The offset current that the Petersen coil controller is operating from the re... direct
position_current 0..1
CurrentFlow
The control current used to control the Petersen coil also known as the posit... direct
x_ground_max 0..1
Reactance
The maximum reactance direct
x_ground_min 0..1
Reactance
The minimum reactance direct
x_ground_nominal 0..1
Reactance
The nominal reactance direct
r 0..1
Resistance
Nominal resistance of device EarthFaultCompensator
protective_action_adjustment 0..*
ProtectiveActionAdjustment
The operating condition to the Conducting Equipment is changed when protectiv... ConductingEquipment
sv_status 0..*
SvStatus
The status state variable associated with this conducting equipment ConductingEquipment
protection_equipments 0..*
ProtectionEquipment
Protection equipment used to protect specific conducting equipment ConductingEquipment
base_voltage 0..1
BaseVoltage
Base voltage of this conducting equipment ConductingEquipment
terminals 0..*
Terminal
Conducting equipment have terminals that may be connected to other conducting... ConductingEquipment
jumping_action 0..1
JumperAction
Jumper action involving jumping operation on this conducting equipment ConductingEquipment
grounding_action 0..1
GroundAction
Action involving grounding operation on this conducting equipment ConductingEquipment
outage 0..1
Outage
The outage that is isolated by the outage isolation equipment ConductingEquipment
aggregate 0..1
Boolean
The aggregate flag provides an alternative way of representing an aggregated ... Equipment
in_service 0..1
Boolean
Specifies the availability of the equipment Equipment
network_analysis_enabled 0..1
Boolean
The equipment is enabled to participate in network analysis Equipment
normally_in_service 0..1
Boolean
Specifies the availability of the equipment under normal operating conditions Equipment
weather_station 0..*
WeatherStation
Equipment
operational_limit_set 0..*
OperationalLimitSet
The operational limit sets associated with this equipment Equipment
contingency_equipment 0..*
ContingencyEquipment
The contingency equipments in which this equipment participates Equipment
equipment_container 0..1
EquipmentContainer
Container of this equipment Equipment
faults 0..*
Fault
All faults on this equipment Equipment
limit_dependency_model 0..*
LimitDependency
Limit dependencymodels organized under this equipment as a means for organizi... Equipment
eqiupment_limit_series_component 0..*
EquipmentLimitSeriesComponent
Equipment limit series calculation component to which this equipment contribu... Equipment
protective_action_equipment 0..*
ProtectiveActionEquipment
Protective action is controlling equipment Equipment
pin_equipment 0..*
PinEquipment
Equipment
equipment_unavailability_schedule 0..*
EquipmentUnavailabilitySchedule
Equipment
additional_equipment_container 0..*
EquipmentContainer
Additional equipment container beyond the primary equipment container Equipment
usage_points 0..*
UsagePoint
All usage points connected to the electrical grid through this equipment Equipment
outages 0..*
Outage
All outages in which this equipment is involved Equipment
operational_restrictions 0..*
OperationalRestriction
All operational restrictions for this equipment Equipment
controls 0..*
Control
The controller outputs used to actually govern a regulating device, e PowerSystemResource
measurements 0..*
Measurement
The measurements associated with this power system resource PowerSystemResource
psrtype 0..1
PSRType
Custom classification for this power system resource PowerSystemResource
configuration_event 0..*
ConfigurationEvent
All configuration events created for this Power System resource PowerSystemResource
reporting_group 0..*
ReportingGroup
Reporting groups to which this power system resource belongs PowerSystemResource
operating_share 0..*
OperatingShare
The operating shares of this power system resource PowerSystemResource
asset_datasheet 0..1
AssetInfo
Datasheet information for this power system resource PowerSystemResource
verification_action 0..*
VerificationAction
The verification action that is performed on the power system resource PowerSystemResource
clearances 0..*
ClearanceDocument
All clearances applicable to this power system resource PowerSystemResource
generic_action 0..*
GenericAction
The generic action that is performed on the power system resource PowerSystemResource
psrevents 0..*
PSREvent
All events associated with this power system resource PowerSystemResource
assets 0..*
Asset
All assets represented by this power system resource PowerSystemResource
location 0..1
Location
Location of this power system resource PowerSystemResource
operational_tags 0..*
OperationalTag
All operational tags placed on this power system resource PowerSystemResource
alias_name 0..1
String
The aliasName is free text human readable name of the object alternative to I... IdentifiedObject
description 0..1
String
The description is a free human readable text describing or naming the object IdentifiedObject
m_rid 0..1
String
Master resource identifier issued by a model authority IdentifiedObject
diagram_objects 0..*
DiagramObject
The diagram objects that are associated with the domain object IdentifiedObject
instance_set 1..1
InstanceSet
Dataset containing the data objects IdentifiedObject
names 0..*
Name
All names of this identified object IdentifiedObject
properties_cimdata_object 0..1
ChangeSetMember
The single CIM data object in the appropriate dataset context IdentifiedObject
targeting_cimdata_object 0..*
ChangeSetMember
Data objects registered IdentifiedObject

Identifier and Mapping Information

Schema Source

  • from schema: https://cim.ucaiug.io/ns#TC57CIM

Mappings

Mapping Type Mapped Value
self cim:PetersenCoil
native cim:PetersenCoil

LinkML Source

Direct

name: PetersenCoil
description: A variable impedance device normally used to offset line charging during
  single line faults in an ungrounded section of network.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
is_a: EarthFaultCompensator
attributes:
  mode:
    name: mode
    description: The mode of operation of the Petersen coil.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:PetersenCoil.mode
    multivalued: false
    domain_of:
    - RegulatingControl
    - PetersenCoil
    range: PetersenCoilModeKind
    required: false
  nominal_u:
    name: nominal_u
    description: The nominal voltage for which the coil is designed.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PetersenCoil.nominalU
    multivalued: false
    domain_of:
    - PetersenCoil
    range: Voltage
    required: false
  offset_current:
    name: offset_current
    description: The offset current that the Petersen coil controller is operating
      from the resonant point.  This is normally a fixed amount for which the controller
      is configured and could be positive or negative.  Typically 0 to 60 A depending
      on voltage and resonance conditions.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PetersenCoil.offsetCurrent
    multivalued: false
    domain_of:
    - PetersenCoil
    range: CurrentFlow
    required: false
  position_current:
    name: position_current
    description: The control current used to control the Petersen coil also known
      as the position current.  Typically in the range of 20 mA to 200 mA.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PetersenCoil.positionCurrent
    multivalued: false
    domain_of:
    - PetersenCoil
    range: CurrentFlow
    required: false
  x_ground_max:
    name: x_ground_max
    description: 'The maximum reactance. '
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PetersenCoil.xGroundMax
    multivalued: false
    domain_of:
    - PetersenCoil
    range: Reactance
    required: false
  x_ground_min:
    name: x_ground_min
    description: The minimum reactance.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PetersenCoil.xGroundMin
    multivalued: false
    domain_of:
    - PetersenCoil
    range: Reactance
    required: false
  x_ground_nominal:
    name: x_ground_nominal
    description: The nominal reactance.  This is the operating point (normally over
      compensation) that is defined based on the resonance point in the healthy network
      condition.  The impedance is calculated based on nominal voltage divided by
      position current.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PetersenCoil.xGroundNominal
    multivalued: false
    domain_of:
    - PetersenCoil
    range: Reactance
    required: false
class_uri: cim:PetersenCoil

Induced

name: PetersenCoil
description: A variable impedance device normally used to offset line charging during
  single line faults in an ungrounded section of network.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
is_a: EarthFaultCompensator
attributes:
  mode:
    name: mode
    description: The mode of operation of the Petersen coil.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:PetersenCoil.mode
    multivalued: false
    alias: mode
    owner: PetersenCoil
    domain_of:
    - RegulatingControl
    - PetersenCoil
    range: PetersenCoilModeKind
    required: false
  nominal_u:
    name: nominal_u
    description: The nominal voltage for which the coil is designed.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PetersenCoil.nominalU
    multivalued: false
    alias: nominal_u
    owner: PetersenCoil
    domain_of:
    - PetersenCoil
    range: Voltage
    required: false
  offset_current:
    name: offset_current
    description: The offset current that the Petersen coil controller is operating
      from the resonant point.  This is normally a fixed amount for which the controller
      is configured and could be positive or negative.  Typically 0 to 60 A depending
      on voltage and resonance conditions.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PetersenCoil.offsetCurrent
    multivalued: false
    alias: offset_current
    owner: PetersenCoil
    domain_of:
    - PetersenCoil
    range: CurrentFlow
    required: false
  position_current:
    name: position_current
    description: The control current used to control the Petersen coil also known
      as the position current.  Typically in the range of 20 mA to 200 mA.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PetersenCoil.positionCurrent
    multivalued: false
    alias: position_current
    owner: PetersenCoil
    domain_of:
    - PetersenCoil
    range: CurrentFlow
    required: false
  x_ground_max:
    name: x_ground_max
    description: 'The maximum reactance. '
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PetersenCoil.xGroundMax
    multivalued: false
    alias: x_ground_max
    owner: PetersenCoil
    domain_of:
    - PetersenCoil
    range: Reactance
    required: false
  x_ground_min:
    name: x_ground_min
    description: The minimum reactance.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PetersenCoil.xGroundMin
    multivalued: false
    alias: x_ground_min
    owner: PetersenCoil
    domain_of:
    - PetersenCoil
    range: Reactance
    required: false
  x_ground_nominal:
    name: x_ground_nominal
    description: The nominal reactance.  This is the operating point (normally over
      compensation) that is defined based on the resonance point in the healthy network
      condition.  The impedance is calculated based on nominal voltage divided by
      position current.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PetersenCoil.xGroundNominal
    multivalued: false
    alias: x_ground_nominal
    owner: PetersenCoil
    domain_of:
    - PetersenCoil
    range: Reactance
    required: false
  r:
    name: r
    description: Nominal resistance of device.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:EarthFaultCompensator.r
    multivalued: false
    alias: r
    owner: PetersenCoil
    domain_of:
    - MutualCoupling
    - TransformerMeshImpedance
    - TransformerEndInfo
    - PowerTransformerEnd
    - ACLineSegment
    - SynchronousMachine
    - EquivalentInjection
    - PowerElectronicsConnection
    - SeriesCompensator
    - TransformerStarImpedance
    - TapChangerTablePoint
    - PerLengthSequenceImpedance
    - PhaseImpedanceData
    - EarthFaultCompensator
    - EnergySource
    - EquivalentBranch
    - DCGround
    - GovCT1
    - GovCT2
    - GovGAST
    - GovGAST1
    - GovHydroDD
    - GovHydroPID
    - GovHydroR
    - GovSteam0
    - GovSteamFV2
    - ExcNI
    - UnderexcLimX2
    range: Resistance
    required: false
  protective_action_adjustment:
    name: protective_action_adjustment
    description: 'The operating condition to the Conducting Equipment is changed when
      protective action adjustment is activated. For ShuntCompensator or other conducting
      equipment that operates on discrete values (integer), the values given in float
      will be rounded. '
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:ConductingEquipment.ProtectiveActionAdjustment
    multivalued: true
    alias: protective_action_adjustment
    owner: PetersenCoil
    domain_of:
    - Measurement
    - ConductingEquipment
    - DCConductingEquipment
    range: ProtectiveActionAdjustment
    required: false
  sv_status:
    name: sv_status
    description: The status state variable associated with this conducting equipment.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:ConductingEquipment.SvStatus
    multivalued: true
    alias: sv_status
    owner: PetersenCoil
    domain_of:
    - ConductingEquipment
    range: SvStatus
    required: false
  protection_equipments:
    name: protection_equipments
    description: 'Protection equipment  used to protect specific conducting equipment. '
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:ConductingEquipment.ProtectionEquipments
    multivalued: true
    alias: protection_equipments
    owner: PetersenCoil
    domain_of:
    - ConductingEquipment
    range: ProtectionEquipment
    required: false
  base_voltage:
    name: base_voltage
    description: Base voltage of this conducting equipment.  Use only when there is
      no voltage level container used and only one base voltage applies.  For example,
      not used for transformers.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:ConductingEquipment.BaseVoltage
    multivalued: false
    alias: base_voltage
    owner: PetersenCoil
    domain_of:
    - TopologicalNode
    - TransformerEnd
    - ConductingEquipment
    - VoltageLevel
    - AssetDeployment
    range: BaseVoltage
    required: false
  terminals:
    name: terminals
    description: Conducting equipment have terminals that may be connected to other
      conducting equipment terminals via connectivity nodes or topological nodes.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:ConductingEquipment.Terminals
    multivalued: true
    alias: terminals
    owner: PetersenCoil
    domain_of:
    - ConnectivityNode
    - ConductingEquipment
    range: Terminal
    required: false
  jumping_action:
    name: jumping_action
    description: Jumper action involving jumping operation on this conducting equipment.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:ConductingEquipment.JumpingAction
    multivalued: false
    alias: jumping_action
    owner: PetersenCoil
    domain_of:
    - ConductingEquipment
    range: JumperAction
    required: false
  grounding_action:
    name: grounding_action
    description: Action involving grounding operation on this conducting equipment.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:ConductingEquipment.GroundingAction
    multivalued: false
    alias: grounding_action
    owner: PetersenCoil
    domain_of:
    - ConductingEquipment
    range: GroundAction
    required: false
  outage:
    name: outage
    description: The outage that is isolated by the outage isolation equipment.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:ConductingEquipment.Outage
    multivalued: false
    alias: outage
    owner: PetersenCoil
    domain_of:
    - Incident
    - SwitchingPlan
    - UsagePoint
    - ConductingEquipment
    - Crew
    - EstimatedRestorationTime
    - OutageArea
    - Fault
    range: Outage
    required: false
  aggregate:
    name: aggregate
    description: "The aggregate flag provides an alternative way of representing an\
      \ aggregated (equivalent) element. It is applicable in cases when the dedicated\
      \ classes for equivalent equipment do not have all of the attributes necessary\
      \ to represent the required level of detail.  In case the flag is set to “true”\
      \ the single instance of equipment represents multiple pieces of equipment that\
      \ have been modelled together as an aggregate equivalent obtained by a network\
      \ reduction procedure. Examples would be power transformers or synchronous machines\
      \ operating in parallel modelled as a single aggregate power transformer or\
      \ aggregate synchronous machine.  \r\nThe attribute is not used for EquivalentBranch,\
      \ EquivalentShunt and EquivalentInjection."
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Equipment.aggregate
    multivalued: false
    alias: aggregate
    owner: PetersenCoil
    domain_of:
    - Equipment
    - ReadingType
    range: boolean
    required: false
  in_service:
    name: in_service
    description: Specifies the availability of the equipment. True means the equipment
      is available for topology processing, which determines if the equipment is energized
      or not. False means that the equipment is treated by network applications as
      if it is not in the model.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Equipment.inService
    multivalued: false
    alias: in_service
    owner: PetersenCoil
    domain_of:
    - Equipment
    - SvStatus
    - ProtectiveActionEquipment
    range: boolean
    required: false
  network_analysis_enabled:
    name: network_analysis_enabled
    description: The equipment is enabled to participate in network analysis.  If
      unspecified, the value is assumed to be true.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Equipment.networkAnalysisEnabled
    multivalued: false
    alias: network_analysis_enabled
    owner: PetersenCoil
    domain_of:
    - Equipment
    range: boolean
    required: false
  normally_in_service:
    name: normally_in_service
    description: Specifies the availability of the equipment under normal operating
      conditions. True means the equipment is available for topology processing, which
      determines if the equipment is energized or not. False means that the equipment
      is treated by network applications as if it is not in the model.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Equipment.normallyInService
    multivalued: false
    alias: normally_in_service
    owner: PetersenCoil
    domain_of:
    - Equipment
    range: boolean
    required: false
  weather_station:
    name: weather_station
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Equipment.WeatherStation
    multivalued: true
    alias: weather_station
    owner: PetersenCoil
    domain_of:
    - Equipment
    range: WeatherStation
    required: false
  operational_limit_set:
    name: operational_limit_set
    description: The operational limit sets associated with this equipment.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:Equipment.OperationalLimitSet
    multivalued: true
    alias: operational_limit_set
    owner: PetersenCoil
    domain_of:
    - ACDCTerminal
    - OperationalLimit
    - Equipment
    range: OperationalLimitSet
    required: false
  contingency_equipment:
    name: contingency_equipment
    description: The contingency equipments in which this equipment participates.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Equipment.ContingencyEquipment
    multivalued: true
    alias: contingency_equipment
    owner: PetersenCoil
    domain_of:
    - Equipment
    range: ContingencyEquipment
    required: false
  equipment_container:
    name: equipment_container
    description: Container of this equipment.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Equipment.EquipmentContainer
    multivalued: false
    alias: equipment_container
    owner: PetersenCoil
    domain_of:
    - Equipment
    range: EquipmentContainer
    required: false
  faults:
    name: faults
    description: All faults on this equipment.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Equipment.Faults
    multivalued: true
    alias: faults
    owner: PetersenCoil
    domain_of:
    - Equipment
    - Outage
    - FaultCauseType
    range: Fault
    required: false
  limit_dependency_model:
    name: limit_dependency_model
    description: Limit dependencymodels organized under this equipment as a means
      for organizing the model in a tree view.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:Equipment.LimitDependencyModel
    multivalued: true
    alias: limit_dependency_model
    owner: PetersenCoil
    domain_of:
    - OperationalLimit
    - Equipment
    range: LimitDependency
    required: false
  eqiupment_limit_series_component:
    name: eqiupment_limit_series_component
    description: Equipment limit series calculation component to which this equipment
      contributes.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Equipment.EqiupmentLimitSeriesComponent
    multivalued: true
    alias: eqiupment_limit_series_component
    owner: PetersenCoil
    domain_of:
    - Equipment
    range: EquipmentLimitSeriesComponent
    required: false
  protective_action_equipment:
    name: protective_action_equipment
    description: Protective action is controlling equipment. This can be direct signals
      from the control center, or emulation of action done by protection equipment.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Equipment.ProtectiveActionEquipment
    multivalued: true
    alias: protective_action_equipment
    owner: PetersenCoil
    domain_of:
    - Equipment
    range: ProtectiveActionEquipment
    required: false
  pin_equipment:
    name: pin_equipment
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Equipment.PinEquipment
    multivalued: true
    alias: pin_equipment
    owner: PetersenCoil
    domain_of:
    - Equipment
    range: PinEquipment
    required: false
  equipment_unavailability_schedule:
    name: equipment_unavailability_schedule
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Equipment.EquipmentUnavailabilitySchedule
    multivalued: true
    alias: equipment_unavailability_schedule
    owner: PetersenCoil
    domain_of:
    - Equipment
    - UnavailabilitySwitchAction
    - UnavailablitySchedule
    range: EquipmentUnavailabilitySchedule
    required: false
  additional_equipment_container:
    name: additional_equipment_container
    description: Additional equipment container beyond the primary equipment container.  The
      equipment is contained in another equipment container, but also grouped with
      this equipment container.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Equipment.AdditionalEquipmentContainer
    multivalued: true
    alias: additional_equipment_container
    owner: PetersenCoil
    domain_of:
    - Equipment
    range: EquipmentContainer
    required: false
  usage_points:
    name: usage_points
    description: All usage points connected to the electrical grid through this equipment.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Equipment.UsagePoints
    multivalued: true
    alias: usage_points
    owner: PetersenCoil
    domain_of:
    - Equipment
    - CustomerAgreement
    - ServiceCategory
    - PricingStructure
    - EndDeviceControl
    - UsagePointGroup
    - ServiceLocation
    - MetrologyRequirement
    - ServiceSupplier
    - UsagePointLocation
    range: UsagePoint
    required: false
  outages:
    name: outages
    description: All outages in which this equipment is involved.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Equipment.Outages
    multivalued: true
    alias: outages
    owner: PetersenCoil
    domain_of:
    - Equipment
    range: Outage
    required: false
  operational_restrictions:
    name: operational_restrictions
    description: All operational restrictions for this equipment.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Equipment.OperationalRestrictions
    multivalued: true
    alias: operational_restrictions
    owner: PetersenCoil
    domain_of:
    - Equipment
    - ProductAssetModel
    range: OperationalRestriction
    required: false
  controls:
    name: controls
    description: The controller outputs used to actually govern a regulating device,
      e.g. the magnetization of a synchronous machine or capacitor bank breaker actuator.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PowerSystemResource.Controls
    multivalued: true
    alias: controls
    owner: PetersenCoil
    domain_of:
    - PowerSystemResource
    - HostControlArea
    range: Control
    required: false
  measurements:
    name: measurements
    description: The measurements associated with this power system resource.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PowerSystemResource.Measurements
    multivalued: true
    alias: measurements
    owner: PetersenCoil
    domain_of:
    - PowerSystemResource
    - ACDCTerminal
    - Asset
    - Location
    - Procedure
    - AnalogLimitSet
    - AccumulatorLimitSet
    range: Measurement
    required: false
  psrtype:
    name: psrtype
    description: Custom classification for this power system resource.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PowerSystemResource.PSRType
    multivalued: false
    alias: psrtype
    owner: PetersenCoil
    domain_of:
    - PowerSystemResource
    range: PSRType
    required: false
  configuration_event:
    name: configuration_event
    description: All configuration events created for this Power System resource.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PowerSystemResource.ConfigurationEvent
    multivalued: true
    alias: configuration_event
    owner: PetersenCoil
    domain_of:
    - PowerSystemResource
    - FaultCauseType
    range: ConfigurationEvent
    required: false
  reporting_group:
    name: reporting_group
    description: Reporting groups to which this power system resource belongs.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PowerSystemResource.ReportingGroup
    multivalued: true
    alias: reporting_group
    owner: PetersenCoil
    domain_of:
    - PowerSystemResource
    - BusNameMarker
    - TopologicalNode
    - ReportingSuperGroup
    range: ReportingGroup
    required: false
  operating_share:
    name: operating_share
    description: The operating shares of this power system resource.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PowerSystemResource.OperatingShare
    multivalued: true
    alias: operating_share
    owner: PetersenCoil
    domain_of:
    - PowerSystemResource
    - OperatingParticipant
    range: OperatingShare
    required: false
  asset_datasheet:
    name: asset_datasheet
    description: Datasheet information for this power system resource.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PowerSystemResource.AssetDatasheet
    multivalued: false
    alias: asset_datasheet
    owner: PetersenCoil
    domain_of:
    - PowerSystemResource
    range: AssetInfo
    required: false
  verification_action:
    name: verification_action
    description: The verification action that is performed on the power system resource
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PowerSystemResource.VerificationAction
    multivalued: true
    alias: verification_action
    owner: PetersenCoil
    domain_of:
    - PowerSystemResource
    range: VerificationAction
    required: false
  clearances:
    name: clearances
    description: All clearances applicable to this power system resource.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PowerSystemResource.Clearances
    multivalued: true
    alias: clearances
    owner: PetersenCoil
    domain_of:
    - PowerSystemResource
    range: ClearanceDocument
    required: false
  generic_action:
    name: generic_action
    description: The generic action that is performed on the power system resource
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PowerSystemResource.GenericAction
    multivalued: true
    alias: generic_action
    owner: PetersenCoil
    domain_of:
    - PowerSystemResource
    range: GenericAction
    required: false
  psrevents:
    name: psrevents
    description: All events associated with this power system resource.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PowerSystemResource.PSREvents
    multivalued: true
    alias: psrevents
    owner: PetersenCoil
    domain_of:
    - PowerSystemResource
    range: PSREvent
    required: false
  assets:
    name: assets
    description: All assets represented by this power system resource. For example,
      multiple conductor assets are electrically modelled as a single AC line segment.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PowerSystemResource.Assets
    multivalued: true
    alias: assets
    owner: PetersenCoil
    domain_of:
    - PowerSystemResource
    - AssetInfo
    - Location
    - WorkTask
    - ErpRecDelvLineItem
    - AssetContainer
    - ActivityRecord
    - Procedure
    - ReliabilityInfo
    - AssetPropertyCurve
    - AssetOrganisationRole
    - ScheduledEvent
    range: Asset
    required: false
  location:
    name: location
    description: Location of this power system resource.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PowerSystemResource.Location
    multivalued: false
    alias: location
    owner: PetersenCoil
    domain_of:
    - PowerSystemResource
    - Asset
    - Incident
    - SwitchingOrder
    - TroubleOrder
    - Crew
    - Fault
    - PointOfSale
    - TroubleTicket
    - OutageOrder
    - EnvironmentalMonitoringStation
    - EnvironmentalLocationType
    - PositionPoint
    - FailureEvent
    range: Location
    required: false
  operational_tags:
    name: operational_tags
    description: All operational tags placed on this power system resource.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PowerSystemResource.OperationalTags
    multivalued: true
    alias: operational_tags
    owner: PetersenCoil
    domain_of:
    - PowerSystemResource
    - Asset
    range: OperationalTag
    required: false
  alias_name:
    name: alias_name
    description: "The aliasName is free text human readable name of the object alternative\
      \ to IdentifiedObject.name. It may be non unique and may not correlate to a\
      \ naming hierarchy.\r\nThe attribute aliasName is retained because of backwards\
      \ compatibility between CIM relases. It is however recommended to replace aliasName\
      \ with the Name class as aliasName is planned for retirement at a future time.\r\
      \n\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.aliasName
    multivalued: false
    alias: alias_name
    owner: PetersenCoil
    domain_of:
    - IdentifiedObject
    range: string
    required: false
  description:
    name: description
    description: The description is a free human readable text describing or naming
      the object. It may be non unique and may not correlate to a naming hierarchy.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.description
    multivalued: false
    alias: description
    owner: PetersenCoil
    domain_of:
    - IdentifiedObject
    - NameType
    - NameTypeAuthority
    - DataSet
    - SwitchingStepGroup
    - AreaReserveSpec
    range: string
    required: false
  m_rid:
    name: m_rid
    description: "Master resource identifier issued by a model authority. The mRID\
      \ is unique within an exchange context. Global uniqueness is easily achieved\
      \ by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is\
      \ strongly recommended.\r\nFor CIMXML data files in RDF syntax conforming to\
      \ IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify\
      \ CIM object elements."
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.mRID
    multivalued: false
    alias: m_rid
    owner: PetersenCoil
    domain_of:
    - IdentifiedObject
    - DataSet
    range: string
    required: false
  diagram_objects:
    name: diagram_objects
    description: The diagram objects that are associated with the domain object.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.DiagramObjects
    multivalued: true
    alias: diagram_objects
    owner: PetersenCoil
    domain_of:
    - IdentifiedObject
    range: DiagramObject
    required: false
  instance_set:
    name: instance_set
    description: Dataset containing the data objects.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.InstanceSet
    multivalued: false
    alias: instance_set
    owner: PetersenCoil
    domain_of:
    - IdentifiedObject
    range: InstanceSet
    required: true
  names:
    name: names
    description: All names of this identified object.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.Names
    multivalued: true
    alias: names
    owner: PetersenCoil
    domain_of:
    - IdentifiedObject
    - NameType
    range: Name
    required: false
  properties_cimdata_object:
    name: properties_cimdata_object
    description: The single CIM data object in the appropriate dataset context.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.PropertiesCIMDataObject
    multivalued: false
    alias: properties_cimdata_object
    owner: PetersenCoil
    domain_of:
    - IdentifiedObject
    range: ChangeSetMember
    required: false
  targeting_cimdata_object:
    name: targeting_cimdata_object
    description: Data objects registered.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.TargetingCIMDataObject
    multivalued: true
    alias: targeting_cimdata_object
    owner: PetersenCoil
    domain_of:
    - IdentifiedObject
    range: ChangeSetMember
    required: false
class_uri: cim:PetersenCoil