Skip to content

Class: OperationalLimitSet

_A set of limits associated with equipment. Sets of limits might apply to a specific temperature, or season for example. A set of limits may contain different severities of limit levels that would apply to the same equipment. The set may contain limits of different types such as apparent power and current limits or high and low voltage limits that are logically applied together as a set. _

__

URI: cim:OperationalLimitSet

 classDiagram
    class OperationalLimitSet
      IdentifiedObject <|-- OperationalLimitSet

      OperationalLimitSet : alias_name

      OperationalLimitSet : description

      OperationalLimitSet : diagram_objects

          OperationalLimitSet --> DiagramObject : diagram_objects

      OperationalLimitSet : equipment

          OperationalLimitSet --> Equipment : equipment

      OperationalLimitSet : instance_set

          OperationalLimitSet --> InstanceSet : instance_set

      OperationalLimitSet : m_rid

      OperationalLimitSet : names

          OperationalLimitSet --> Name : names

      OperationalLimitSet : operational_limit_value

          OperationalLimitSet --> OperationalLimit : operational_limit_value

      OperationalLimitSet : properties_cimdata_object

          OperationalLimitSet --> ChangeSetMember : properties_cimdata_object

      OperationalLimitSet : targeting_cimdata_object

          OperationalLimitSet --> ChangeSetMember : targeting_cimdata_object

      OperationalLimitSet : terminal

          OperationalLimitSet --> ACDCTerminal : terminal

Inheritance

Slots

Name Cardinality and Range Description Inheritance
equipment 0..1
Equipment
The equipment to which the limit set applies direct
terminal 0..1
ACDCTerminal
The terminal where the operational limit set apply direct
operational_limit_value 0..*
OperationalLimit
Values of equipment limits direct
alias_name 0..1
String
The aliasName is free text human readable name of the object alternative to I... IdentifiedObject
description 0..1
String
The description is a free human readable text describing or naming the object IdentifiedObject
m_rid 0..1
String
Master resource identifier issued by a model authority IdentifiedObject
diagram_objects 0..*
DiagramObject
The diagram objects that are associated with the domain object IdentifiedObject
instance_set 1..1
InstanceSet
Dataset containing the data objects IdentifiedObject
names 0..*
Name
All names of this identified object IdentifiedObject
properties_cimdata_object 0..1
ChangeSetMember
The single CIM data object in the appropriate dataset context IdentifiedObject
targeting_cimdata_object 0..*
ChangeSetMember
Data objects registered IdentifiedObject

Usages

used by used in type used
ACDCTerminal operational_limit_set range OperationalLimitSet
OperationalLimit operational_limit_set range OperationalLimitSet
Equipment operational_limit_set range OperationalLimitSet
Terminal operational_limit_set range OperationalLimitSet
ProtectionEquipment operational_limit_set range OperationalLimitSet
ProtectedSwitch operational_limit_set range OperationalLimitSet
Switch operational_limit_set range OperationalLimitSet
ConductingEquipment operational_limit_set range OperationalLimitSet
DCBaseTerminal operational_limit_set range OperationalLimitSet
TransformerTank operational_limit_set range OperationalLimitSet
PowerTransformer operational_limit_set range OperationalLimitSet
Clamp operational_limit_set range OperationalLimitSet
ACLineSegment operational_limit_set range OperationalLimitSet
Conductor operational_limit_set range OperationalLimitSet
Cut operational_limit_set range OperationalLimitSet
Ground operational_limit_set range OperationalLimitSet
Jumper operational_limit_set range OperationalLimitSet
DCConductingEquipment operational_limit_set range OperationalLimitSet
DCTerminal operational_limit_set range OperationalLimitSet
CompositeSwitch operational_limit_set range OperationalLimitSet
ThermalGeneratingUnit operational_limit_set range OperationalLimitSet
GeneratingUnit operational_limit_set range OperationalLimitSet
EnergyConnection operational_limit_set range OperationalLimitSet
RotatingMachine operational_limit_set range OperationalLimitSet
RegulatingCondEq operational_limit_set range OperationalLimitSet
BusbarSection operational_limit_set range OperationalLimitSet
Connector operational_limit_set range OperationalLimitSet
HydroPump operational_limit_set range OperationalLimitSet
HydroGeneratingUnit operational_limit_set range OperationalLimitSet
SynchronousMachine operational_limit_set range OperationalLimitSet
EquivalentInjection operational_limit_set range OperationalLimitSet
EquivalentEquipment operational_limit_set range OperationalLimitSet
PowerElectronicsConnection operational_limit_set range OperationalLimitSet
PowerElectronicsUnit operational_limit_set range OperationalLimitSet
AsynchronousMachine operational_limit_set range OperationalLimitSet
MktGeneratingUnit operational_limit_set range OperationalLimitSet
MktTerminal operational_limit_set range OperationalLimitSet
MktPowerTransformer operational_limit_set range OperationalLimitSet
MktSeriesCompensator operational_limit_set range OperationalLimitSet
SeriesCompensator operational_limit_set range OperationalLimitSet
MktACLineSegment operational_limit_set range OperationalLimitSet
MktThermalGeneratingUnit operational_limit_set range OperationalLimitSet
AuxiliaryEquipment operational_limit_set range OperationalLimitSet
ACDCConverter operational_limit_set range OperationalLimitSet
ACDCConverterDCTerminal operational_limit_set range OperationalLimitSet
ActivePowerLimit operational_limit_set range OperationalLimitSet
ApparentPowerLimit operational_limit_set range OperationalLimitSet
CurrentLimit operational_limit_set range OperationalLimitSet
VoltageLimit operational_limit_set range OperationalLimitSet
ShuntCompensator operational_limit_set range OperationalLimitSet
Disconnector operational_limit_set range OperationalLimitSet
EnergyConsumer operational_limit_set range OperationalLimitSet
Breaker operational_limit_set range OperationalLimitSet
GroundDisconnector operational_limit_set range OperationalLimitSet
Fuse operational_limit_set range OperationalLimitSet
PetersenCoil operational_limit_set range OperationalLimitSet
EarthFaultCompensator operational_limit_set range OperationalLimitSet
GroundingImpedance operational_limit_set range OperationalLimitSet
Recloser operational_limit_set range OperationalLimitSet
Sectionaliser operational_limit_set range OperationalLimitSet
EnergySource operational_limit_set range OperationalLimitSet
StaticVarCompensator operational_limit_set range OperationalLimitSet
Junction operational_limit_set range OperationalLimitSet
FrequencyConverter operational_limit_set range OperationalLimitSet
LoadBreakSwitch operational_limit_set range OperationalLimitSet
ExternalNetworkInjection operational_limit_set range OperationalLimitSet
LinearShuntCompensator operational_limit_set range OperationalLimitSet
NonlinearShuntCompensator operational_limit_set range OperationalLimitSet
WireSegment operational_limit_set range OperationalLimitSet
DisconnectingCircuitBreaker operational_limit_set range OperationalLimitSet
NuclearGeneratingUnit operational_limit_set range OperationalLimitSet
WindGeneratingUnit operational_limit_set range OperationalLimitSet
SolarGeneratingUnit operational_limit_set range OperationalLimitSet
BatteryUnit operational_limit_set range OperationalLimitSet
PhotoVoltaicUnit operational_limit_set range OperationalLimitSet
PowerElectronicsWindUnit operational_limit_set range OperationalLimitSet
ConformLoad operational_limit_set range OperationalLimitSet
NonConformLoad operational_limit_set range OperationalLimitSet
StationSupply operational_limit_set range OperationalLimitSet
Sensor operational_limit_set range OperationalLimitSet
CurrentTransformer operational_limit_set range OperationalLimitSet
WaveTrap operational_limit_set range OperationalLimitSet
SurgeArrester operational_limit_set range OperationalLimitSet
PostLineSensor operational_limit_set range OperationalLimitSet
PotentialTransformer operational_limit_set range OperationalLimitSet
FaultIndicator operational_limit_set range OperationalLimitSet
CurrentRelay operational_limit_set range OperationalLimitSet
SynchrocheckRelay operational_limit_set range OperationalLimitSet
EquivalentShunt operational_limit_set range OperationalLimitSet
EquivalentBranch operational_limit_set range OperationalLimitSet
DCLineSegment operational_limit_set range OperationalLimitSet
DCBreaker operational_limit_set range OperationalLimitSet
DCSwitch operational_limit_set range OperationalLimitSet
DCBusbar operational_limit_set range OperationalLimitSet
DCDisconnector operational_limit_set range OperationalLimitSet
DCGround operational_limit_set range OperationalLimitSet
DCShunt operational_limit_set range OperationalLimitSet
VsConverter operational_limit_set range OperationalLimitSet
CsConverter operational_limit_set range OperationalLimitSet
DCChopper operational_limit_set range OperationalLimitSet
DCSeriesDevice operational_limit_set range OperationalLimitSet
SVC operational_limit_set range OperationalLimitSet
MktShuntCompensator operational_limit_set range OperationalLimitSet
MktSwitch operational_limit_set range OperationalLimitSet
MktConductingEquipment operational_limit_set range OperationalLimitSet

Identifier and Mapping Information

Schema Source

  • from schema: https://cim.ucaiug.io/ns#TC57CIM

Mappings

Mapping Type Mapped Value
self cim:OperationalLimitSet
native cim:OperationalLimitSet

LinkML Source

Direct

name: OperationalLimitSet
description: "A set of limits associated with equipment.  Sets of limits might apply\
  \ to a specific temperature, or season for example. A set of limits may contain\
  \ different severities of limit levels that would apply to the same equipment. The\
  \ set may contain limits of different types such as apparent power and current limits\
  \ or high and low voltage limits  that are logically applied together as a set.\r\
  \n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
is_a: IdentifiedObject
attributes:
  equipment:
    name: equipment
    description: The equipment to which the limit set applies.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:OperationalLimitSet.Equipment
    multivalued: false
    domain_of:
    - OperationalLimitSet
    - LimitDependency
    - ContingencyEquipment
    - EquipmentUnavailabilitySchedule
    - EquipmentLimitSeriesComponent
    - ProtectiveActionEquipment
    - PinEquipment
    - WeatherStation
    range: Equipment
    required: false
  terminal:
    name: terminal
    description: The terminal where the operational limit set apply.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:OperationalLimitSet.Terminal
    multivalued: false
    domain_of:
    - BusNameMarker
    - OperationalLimitSet
    - TopologicalNode
    - TransformerEnd
    - Measurement
    - Bushing
    - TieFlow
    - SvPowerFlow
    - RegulatingControl
    - RemoteInputSignal
    - BranchGroupTerminal
    - AuxiliaryEquipment
    - EquipmentFault
    - PinTerminal
    range: ACDCTerminal
    required: false
  operational_limit_value:
    name: operational_limit_value
    description: Values of equipment limits.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:OperationalLimitSet.OperationalLimitValue
    multivalued: true
    domain_of:
    - OperationalLimitSet
    range: OperationalLimit
    required: false
class_uri: cim:OperationalLimitSet

Induced

name: OperationalLimitSet
description: "A set of limits associated with equipment.  Sets of limits might apply\
  \ to a specific temperature, or season for example. A set of limits may contain\
  \ different severities of limit levels that would apply to the same equipment. The\
  \ set may contain limits of different types such as apparent power and current limits\
  \ or high and low voltage limits  that are logically applied together as a set.\r\
  \n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
is_a: IdentifiedObject
attributes:
  equipment:
    name: equipment
    description: The equipment to which the limit set applies.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:OperationalLimitSet.Equipment
    multivalued: false
    alias: equipment
    owner: OperationalLimitSet
    domain_of:
    - OperationalLimitSet
    - LimitDependency
    - ContingencyEquipment
    - EquipmentUnavailabilitySchedule
    - EquipmentLimitSeriesComponent
    - ProtectiveActionEquipment
    - PinEquipment
    - WeatherStation
    range: Equipment
    required: false
  terminal:
    name: terminal
    description: The terminal where the operational limit set apply.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:OperationalLimitSet.Terminal
    multivalued: false
    alias: terminal
    owner: OperationalLimitSet
    domain_of:
    - BusNameMarker
    - OperationalLimitSet
    - TopologicalNode
    - TransformerEnd
    - Measurement
    - Bushing
    - TieFlow
    - SvPowerFlow
    - RegulatingControl
    - RemoteInputSignal
    - BranchGroupTerminal
    - AuxiliaryEquipment
    - EquipmentFault
    - PinTerminal
    range: ACDCTerminal
    required: false
  operational_limit_value:
    name: operational_limit_value
    description: Values of equipment limits.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:OperationalLimitSet.OperationalLimitValue
    multivalued: true
    alias: operational_limit_value
    owner: OperationalLimitSet
    domain_of:
    - OperationalLimitSet
    range: OperationalLimit
    required: false
  alias_name:
    name: alias_name
    description: "The aliasName is free text human readable name of the object alternative\
      \ to IdentifiedObject.name. It may be non unique and may not correlate to a\
      \ naming hierarchy.\r\nThe attribute aliasName is retained because of backwards\
      \ compatibility between CIM relases. It is however recommended to replace aliasName\
      \ with the Name class as aliasName is planned for retirement at a future time.\r\
      \n\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.aliasName
    multivalued: false
    alias: alias_name
    owner: OperationalLimitSet
    domain_of:
    - IdentifiedObject
    range: string
    required: false
  description:
    name: description
    description: The description is a free human readable text describing or naming
      the object. It may be non unique and may not correlate to a naming hierarchy.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.description
    multivalued: false
    alias: description
    owner: OperationalLimitSet
    domain_of:
    - IdentifiedObject
    - NameType
    - NameTypeAuthority
    - DataSet
    - SwitchingStepGroup
    - AreaReserveSpec
    range: string
    required: false
  m_rid:
    name: m_rid
    description: "Master resource identifier issued by a model authority. The mRID\
      \ is unique within an exchange context. Global uniqueness is easily achieved\
      \ by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is\
      \ strongly recommended.\r\nFor CIMXML data files in RDF syntax conforming to\
      \ IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify\
      \ CIM object elements."
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.mRID
    multivalued: false
    alias: m_rid
    owner: OperationalLimitSet
    domain_of:
    - IdentifiedObject
    - DataSet
    range: string
    required: false
  diagram_objects:
    name: diagram_objects
    description: The diagram objects that are associated with the domain object.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.DiagramObjects
    multivalued: true
    alias: diagram_objects
    owner: OperationalLimitSet
    domain_of:
    - IdentifiedObject
    range: DiagramObject
    required: false
  instance_set:
    name: instance_set
    description: Dataset containing the data objects.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.InstanceSet
    multivalued: false
    alias: instance_set
    owner: OperationalLimitSet
    domain_of:
    - IdentifiedObject
    range: InstanceSet
    required: true
  names:
    name: names
    description: All names of this identified object.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.Names
    multivalued: true
    alias: names
    owner: OperationalLimitSet
    domain_of:
    - IdentifiedObject
    - NameType
    range: Name
    required: false
  properties_cimdata_object:
    name: properties_cimdata_object
    description: The single CIM data object in the appropriate dataset context.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.PropertiesCIMDataObject
    multivalued: false
    alias: properties_cimdata_object
    owner: OperationalLimitSet
    domain_of:
    - IdentifiedObject
    range: ChangeSetMember
    required: false
  targeting_cimdata_object:
    name: targeting_cimdata_object
    description: Data objects registered.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.TargetingCIMDataObject
    multivalued: true
    alias: targeting_cimdata_object
    owner: OperationalLimitSet
    domain_of:
    - IdentifiedObject
    range: ChangeSetMember
    required: false
class_uri: cim:OperationalLimitSet