Class: OperationalLimitSet
_A set of limits associated with equipment. Sets of limits might apply to a specific temperature, or season for example. A set of limits may contain different severities of limit levels that would apply to the same equipment. The set may contain limits of different types such as apparent power and current limits or high and low voltage limits that are logically applied together as a set. _
__
classDiagram
class OperationalLimitSet
IdentifiedObject <|-- OperationalLimitSet
OperationalLimitSet : alias_name
OperationalLimitSet : description
OperationalLimitSet : diagram_objects
OperationalLimitSet --> DiagramObject : diagram_objects
OperationalLimitSet : equipment
OperationalLimitSet --> Equipment : equipment
OperationalLimitSet : instance_set
OperationalLimitSet --> InstanceSet : instance_set
OperationalLimitSet : m_rid
OperationalLimitSet : names
OperationalLimitSet --> Name : names
OperationalLimitSet : operational_limit_value
OperationalLimitSet --> OperationalLimit : operational_limit_value
OperationalLimitSet : properties_cimdata_object
OperationalLimitSet --> ChangeSetMember : properties_cimdata_object
OperationalLimitSet : targeting_cimdata_object
OperationalLimitSet --> ChangeSetMember : targeting_cimdata_object
OperationalLimitSet : terminal
OperationalLimitSet --> ACDCTerminal : terminal
Inheritance
- IdentifiedObject
- OperationalLimitSet
Slots
| Name | Cardinality and Range | Description | Inheritance |
|---|---|---|---|
| equipment | 0..1 Equipment |
The equipment to which the limit set applies | direct |
| terminal | 0..1 ACDCTerminal |
The terminal where the operational limit set apply | direct |
| operational_limit_value | 0..* OperationalLimit |
Values of equipment limits | direct |
| alias_name | 0..1 String |
The aliasName is free text human readable name of the object alternative to I... | IdentifiedObject |
| description | 0..1 String |
The description is a free human readable text describing or naming the object | IdentifiedObject |
| m_rid | 0..1 String |
Master resource identifier issued by a model authority | IdentifiedObject |
| diagram_objects | 0..* DiagramObject |
The diagram objects that are associated with the domain object | IdentifiedObject |
| instance_set | 1..1 InstanceSet |
Dataset containing the data objects | IdentifiedObject |
| names | 0..* Name |
All names of this identified object | IdentifiedObject |
| properties_cimdata_object | 0..1 ChangeSetMember |
The single CIM data object in the appropriate dataset context | IdentifiedObject |
| targeting_cimdata_object | 0..* ChangeSetMember |
Data objects registered | IdentifiedObject |
Usages
Identifier and Mapping Information
Schema Source
- from schema: https://cim.ucaiug.io/ns#TC57CIM
Mappings
| Mapping Type | Mapped Value |
|---|---|
| self | cim:OperationalLimitSet |
| native | cim:OperationalLimitSet |
LinkML Source
Direct
name: OperationalLimitSet
description: "A set of limits associated with equipment. Sets of limits might apply\
\ to a specific temperature, or season for example. A set of limits may contain\
\ different severities of limit levels that would apply to the same equipment. The\
\ set may contain limits of different types such as apparent power and current limits\
\ or high and low voltage limits that are logically applied together as a set.\r\
\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
is_a: IdentifiedObject
attributes:
equipment:
name: equipment
description: The equipment to which the limit set applies.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:OperationalLimitSet.Equipment
multivalued: false
domain_of:
- OperationalLimitSet
- LimitDependency
- ContingencyEquipment
- EquipmentUnavailabilitySchedule
- EquipmentLimitSeriesComponent
- ProtectiveActionEquipment
- PinEquipment
- WeatherStation
range: Equipment
required: false
terminal:
name: terminal
description: The terminal where the operational limit set apply.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:OperationalLimitSet.Terminal
multivalued: false
domain_of:
- BusNameMarker
- OperationalLimitSet
- TopologicalNode
- TransformerEnd
- Measurement
- Bushing
- TieFlow
- SvPowerFlow
- RegulatingControl
- RemoteInputSignal
- BranchGroupTerminal
- AuxiliaryEquipment
- EquipmentFault
- PinTerminal
range: ACDCTerminal
required: false
operational_limit_value:
name: operational_limit_value
description: Values of equipment limits.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:OperationalLimitSet.OperationalLimitValue
multivalued: true
domain_of:
- OperationalLimitSet
range: OperationalLimit
required: false
class_uri: cim:OperationalLimitSet
Induced
name: OperationalLimitSet
description: "A set of limits associated with equipment. Sets of limits might apply\
\ to a specific temperature, or season for example. A set of limits may contain\
\ different severities of limit levels that would apply to the same equipment. The\
\ set may contain limits of different types such as apparent power and current limits\
\ or high and low voltage limits that are logically applied together as a set.\r\
\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
is_a: IdentifiedObject
attributes:
equipment:
name: equipment
description: The equipment to which the limit set applies.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:OperationalLimitSet.Equipment
multivalued: false
alias: equipment
owner: OperationalLimitSet
domain_of:
- OperationalLimitSet
- LimitDependency
- ContingencyEquipment
- EquipmentUnavailabilitySchedule
- EquipmentLimitSeriesComponent
- ProtectiveActionEquipment
- PinEquipment
- WeatherStation
range: Equipment
required: false
terminal:
name: terminal
description: The terminal where the operational limit set apply.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:OperationalLimitSet.Terminal
multivalued: false
alias: terminal
owner: OperationalLimitSet
domain_of:
- BusNameMarker
- OperationalLimitSet
- TopologicalNode
- TransformerEnd
- Measurement
- Bushing
- TieFlow
- SvPowerFlow
- RegulatingControl
- RemoteInputSignal
- BranchGroupTerminal
- AuxiliaryEquipment
- EquipmentFault
- PinTerminal
range: ACDCTerminal
required: false
operational_limit_value:
name: operational_limit_value
description: Values of equipment limits.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:OperationalLimitSet.OperationalLimitValue
multivalued: true
alias: operational_limit_value
owner: OperationalLimitSet
domain_of:
- OperationalLimitSet
range: OperationalLimit
required: false
alias_name:
name: alias_name
description: "The aliasName is free text human readable name of the object alternative\
\ to IdentifiedObject.name. It may be non unique and may not correlate to a\
\ naming hierarchy.\r\nThe attribute aliasName is retained because of backwards\
\ compatibility between CIM relases. It is however recommended to replace aliasName\
\ with the Name class as aliasName is planned for retirement at a future time.\r\
\n\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.aliasName
multivalued: false
alias: alias_name
owner: OperationalLimitSet
domain_of:
- IdentifiedObject
range: string
required: false
description:
name: description
description: The description is a free human readable text describing or naming
the object. It may be non unique and may not correlate to a naming hierarchy.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.description
multivalued: false
alias: description
owner: OperationalLimitSet
domain_of:
- IdentifiedObject
- NameType
- NameTypeAuthority
- DataSet
- SwitchingStepGroup
- AreaReserveSpec
range: string
required: false
m_rid:
name: m_rid
description: "Master resource identifier issued by a model authority. The mRID\
\ is unique within an exchange context. Global uniqueness is easily achieved\
\ by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is\
\ strongly recommended.\r\nFor CIMXML data files in RDF syntax conforming to\
\ IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify\
\ CIM object elements."
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.mRID
multivalued: false
alias: m_rid
owner: OperationalLimitSet
domain_of:
- IdentifiedObject
- DataSet
range: string
required: false
diagram_objects:
name: diagram_objects
description: The diagram objects that are associated with the domain object.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.DiagramObjects
multivalued: true
alias: diagram_objects
owner: OperationalLimitSet
domain_of:
- IdentifiedObject
range: DiagramObject
required: false
instance_set:
name: instance_set
description: Dataset containing the data objects.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.InstanceSet
multivalued: false
alias: instance_set
owner: OperationalLimitSet
domain_of:
- IdentifiedObject
range: InstanceSet
required: true
names:
name: names
description: All names of this identified object.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.Names
multivalued: true
alias: names
owner: OperationalLimitSet
domain_of:
- IdentifiedObject
- NameType
range: Name
required: false
properties_cimdata_object:
name: properties_cimdata_object
description: The single CIM data object in the appropriate dataset context.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.PropertiesCIMDataObject
multivalued: false
alias: properties_cimdata_object
owner: OperationalLimitSet
domain_of:
- IdentifiedObject
range: ChangeSetMember
required: false
targeting_cimdata_object:
name: targeting_cimdata_object
description: Data objects registered.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.TargetingCIMDataObject
multivalued: true
alias: targeting_cimdata_object
owner: OperationalLimitSet
domain_of:
- IdentifiedObject
range: ChangeSetMember
required: false
class_uri: cim:OperationalLimitSet