Skip to content

Class: Measurement

_A Measurement represents any measured, calculated or non-measured non-calculated quantity. Any piece of equipment may contain Measurements, e.g. a substation may have temperature measurements and door open indications, a transformer may have oil temperature and tank pressure measurements, a bay may contain a number of power flow measurements and a Breaker may contain a switch status measurement. _

_The PSR - Measurement association is intended to capture this use of Measurement and is included in the naming hierarchy based on EquipmentContainer. The naming hierarchy typically has Measurements as leaves, e.g. Substation-VoltageLevel-Bay-Switch-Measurement. _

_Some Measurements represent quantities related to a particular sensor location in the network, e.g. a voltage transformer (VT) or potential transformer (PT) at a busbar or a current transformer (CT) at the bar between a breaker and an isolator. The sensing position is not captured in the PSR - Measurement association. Instead it is captured by the Measurement - Terminal association that is used to define the sensing location in the network topology. The location is defined by the connection of the Terminal to ConductingEquipment. _

_If both a Terminal and PSR are associated, and the PSR is of type ConductingEquipment, the associated Terminal should belong to that ConductingEquipment instance. _

When the sensor location is needed both Measurement-PSR and Measurement-Terminal are used. The Measurement-Terminal association is never used alone.

URI: cim:Measurement

 classDiagram
    class Measurement
      IdentifiedObject <|-- Measurement


      Measurement <|-- MktMeasurement
      Measurement <|-- Analog
      Measurement <|-- StringMeasurement
      Measurement <|-- Discrete
      Measurement <|-- Accumulator


      Measurement : alias_name

      Measurement : asset

          Measurement --> Asset : asset

      Measurement : calculation_method_hierarchy

          Measurement --> CalculationMethodHierarchy : calculation_method_hierarchy

      Measurement : description

      Measurement : diagram_objects

          Measurement --> DiagramObject : diagram_objects

      Measurement : instance_set

          Measurement --> InstanceSet : instance_set

      Measurement : locations

          Measurement --> Location : locations

      Measurement : m_rid

      Measurement : measurement_action

          Measurement --> MeasurementAction : measurement_action

      Measurement : measurement_calculator_input

          Measurement --> MeasurementCalculatorInput : measurement_calculator_input

      Measurement : measurement_type

      Measurement : names

          Measurement --> Name : names

      Measurement : phases

          Measurement --> PhaseCode : phases

      Measurement : pin_measurement

          Measurement --> PinMeasurement : pin_measurement

      Measurement : power_system_resource

          Measurement --> PowerSystemResource : power_system_resource

      Measurement : procedures

          Measurement --> Procedure : procedures

      Measurement : properties_cimdata_object

          Measurement --> ChangeSetMember : properties_cimdata_object

      Measurement : protective_action_adjustment

          Measurement --> ProtectiveActionAdjustment : protective_action_adjustment

      Measurement : targeting_cimdata_object

          Measurement --> ChangeSetMember : targeting_cimdata_object

      Measurement : terminal

          Measurement --> ACDCTerminal : terminal

      Measurement : unit_multiplier

          Measurement --> UnitMultiplier : unit_multiplier

      Measurement : unit_symbol

          Measurement --> UnitSymbol : unit_symbol

Inheritance

Slots

Name Cardinality and Range Description Inheritance
measurement_type 0..1
String
Specifies the type of measurement direct
phases 0..1
PhaseCode
Indicates to which phases the measurement applies and avoids the need to use ... direct
unit_multiplier 0..1
UnitMultiplier
The unit multiplier of the measured quantity direct
unit_symbol 0..1
UnitSymbol
The unit of measure of the measured quantity direct
terminal 0..1
ACDCTerminal
One or more measurements may be associated with a terminal in the network direct
protective_action_adjustment 0..*
ProtectiveActionAdjustment
direct
calculation_method_hierarchy 0..1
CalculationMethodHierarchy
Calculation method hierarchy which applies to this analog direct
power_system_resource 0..1
PowerSystemResource
The power system resource that contains the measurement direct
pin_measurement 0..*
PinMeasurement
direct
measurement_calculator_input 0..*
MeasurementCalculatorInput
direct
asset 0..1
Asset
Asset that has a measurement direct
measurement_action 0..1
MeasurementAction
The measurement action that is performed on the measurement direct
locations 0..*
Location
Location of this measurement direct
procedures 0..*
Procedure
Measurements are specified in types of documents, such as procedures direct
alias_name 0..1
String
The aliasName is free text human readable name of the object alternative to I... IdentifiedObject
description 0..1
String
The description is a free human readable text describing or naming the object IdentifiedObject
m_rid 0..1
String
Master resource identifier issued by a model authority IdentifiedObject
diagram_objects 0..*
DiagramObject
The diagram objects that are associated with the domain object IdentifiedObject
instance_set 1..1
InstanceSet
Dataset containing the data objects IdentifiedObject
names 0..*
Name
All names of this identified object IdentifiedObject
properties_cimdata_object 0..1
ChangeSetMember
The single CIM data object in the appropriate dataset context IdentifiedObject
targeting_cimdata_object 0..*
ChangeSetMember
Data objects registered IdentifiedObject

Usages

used by used in type used
PowerSystemResource measurements range Measurement
ACDCTerminal measurements range Measurement
Equipment measurements range Measurement
EquipmentContainer measurements range Measurement
ConnectivityNodeContainer measurements range Measurement
Terminal measurements range Measurement
Asset measurements range Measurement
Location measurements range Measurement
WorkLocation measurements range Measurement
AssetContainer measurements range Measurement
CommunicationLink measurements range Measurement
RemoteUnit measurements range Measurement
CalculationMethodHierarchy measurement range Measurement
PinMeasurement measurement range Measurement
ProtectionEquipment measurements range Measurement
ProtectedSwitch measurements range Measurement
Switch measurements range Measurement
ConductingEquipment measurements range Measurement
VoltageLevel measurements range Measurement
Substation measurements range Measurement
DCLine measurements range Measurement
DCEquipmentContainer measurements range Measurement
DCBaseTerminal measurements range Measurement
Line measurements range Measurement
Bay measurements range Measurement
Circuit measurements range Measurement
DCConverterUnit measurements range Measurement
Feeder measurements range Measurement
Procedure measurements range Measurement
Bushing measurements range Measurement
InterrupterUnit measurements range Measurement
OperatingMechanism measurements range Measurement
TransformerTank measurements range Measurement
PowerTransformer measurements range Measurement
Meter measurements range Measurement
EndDevice measurements range Measurement
ServiceLocation measurements range Measurement
WorkAsset measurements range Measurement
Clamp measurements range Measurement
ACLineSegment measurements range Measurement
Conductor measurements range Measurement
DuctBank measurements range Measurement
Structure measurements range Measurement
StructureSupport measurements range Measurement
ACLineSegmentPhase measurements range Measurement
Cut measurements range Measurement
Ground measurements range Measurement
Jumper measurements range Measurement
ProtectiveActionAdjustment measurement range Measurement
DCConductingEquipment measurements range Measurement
DCTerminal measurements range Measurement
CompositeSwitch measurements range Measurement
SwitchPhase measurements range Measurement
RemedialActionScheme measurements range Measurement
MeasurementCalculatorInput measurement range Measurement
MeasurementAction measurement range Measurement
UsagePointLocation measurements range Measurement
RegisteredResource measurements range Measurement
TransmissionCorridor measurements range Measurement
TransmissionRightOfWay measurements range Measurement
MktLine measurements range Measurement
Flowgate measurements range Measurement
SubControlArea measurements range Measurement
HostControlArea measurements range Measurement
RegisteredGenerator measurements range Measurement
RegisteredInterTie measurements range Measurement
RegisteredLoad measurements range Measurement
ThermalGeneratingUnit measurements range Measurement
GeneratingUnit measurements range Measurement
ControlArea measurements range Measurement
EnergyGroup measurements range Measurement
EnergyConnection measurements range Measurement
RotatingMachine measurements range Measurement
RegulatingCondEq measurements range Measurement
RegulatingControl measurements range Measurement
VoltageControlZone measurements range Measurement
BusbarSection measurements range Measurement
Connector measurements range Measurement
HydroPump measurements range Measurement
HydroPowerPlant measurements range Measurement
Reservoir measurements range Measurement
HydroGeneratingUnit measurements range Measurement
CogenerationPlant measurements range Measurement
CAESPlant measurements range Measurement
AirCompressor measurements range Measurement
CombustionTurbine measurements range Measurement
PrimeMover measurements range Measurement
SynchronousMachine measurements range Measurement
EquivalentInjection measurements range Measurement
EquivalentEquipment measurements range Measurement
EquivalentNetwork measurements range Measurement
PowerElectronicsConnection measurements range Measurement
PowerElectronicsUnit measurements range Measurement
PowerElectronicsConnectionPhase measurements range Measurement
AsynchronousMachine measurements range Measurement
HeatRecoveryBoiler measurements range Measurement
FossilSteamSupply measurements range Measurement
SteamSupply measurements range Measurement
SteamTurbine measurements range Measurement
CombinedCyclePlant measurements range Measurement
MktGeneratingUnit measurements range Measurement
MktTerminal measurements range Measurement
MktPowerTransformer measurements range Measurement
MktSeriesCompensator measurements range Measurement
SeriesCompensator measurements range Measurement
MktACLineSegment measurements range Measurement
MktCombinedCyclePlant measurements range Measurement
CombinedCycleConfiguration measurements range Measurement
MktThermalGeneratingUnit measurements range Measurement
PhaseTapChanger measurements range Measurement
TapChanger measurements range Measurement
TapChangerControl measurements range Measurement
RatioTapChanger measurements range Measurement
AuxiliaryEquipment measurements range Measurement
ACDCConverter measurements range Measurement
ACDCConverterDCTerminal measurements range Measurement
WeatherStation measurements range Measurement
ShuntCompensatorPhase measurements range Measurement
ShuntCompensator measurements range Measurement
Disconnector measurements range Measurement
EnergyConsumerPhase measurements range Measurement
EnergyConsumer measurements range Measurement
PowerCutZone measurements range Measurement
PhaseTapChangerTabular measurements range Measurement
Breaker measurements range Measurement
GroundDisconnector measurements range Measurement
PhaseTapChangerAsymmetrical measurements range Measurement
PhaseTapChangerNonLinear measurements range Measurement
PhaseTapChangerSymmetrical measurements range Measurement
Fuse measurements range Measurement
PetersenCoil measurements range Measurement
EarthFaultCompensator measurements range Measurement
GroundingImpedance measurements range Measurement
Recloser measurements range Measurement
Sectionaliser measurements range Measurement
EnergySource measurements range Measurement
EnergySourcePhase measurements range Measurement
StaticVarCompensator measurements range Measurement
Junction measurements range Measurement
PhaseTapChangerLinear measurements range Measurement
FrequencyConverter measurements range Measurement
Plant measurements range Measurement
LoadBreakSwitch measurements range Measurement
ExternalNetworkInjection measurements range Measurement
LinearShuntCompensator measurements range Measurement
NonlinearShuntCompensator measurements range Measurement
LinearShuntCompensatorPhase measurements range Measurement
NonlinearShuntCompensatorPhase measurements range Measurement
WireSegment measurements range Measurement
WireSegmentPhase measurements range Measurement
DisconnectingCircuitBreaker measurements range Measurement
PWRSteamSupply measurements range Measurement
BWRSteamSupply measurements range Measurement
Subcritical measurements range Measurement
DrumBoiler measurements range Measurement
Supercritical measurements range Measurement
HydroTurbine measurements range Measurement
NuclearGeneratingUnit measurements range Measurement
WindGeneratingUnit measurements range Measurement
SolarGeneratingUnit measurements range Measurement
BatteryUnit measurements range Measurement
PhotoVoltaicUnit measurements range Measurement
PowerElectronicsWindUnit measurements range Measurement
ConformLoad measurements range Measurement
NonConformLoad measurements range Measurement
StationSupply measurements range Measurement
Sensor measurements range Measurement
CurrentTransformer measurements range Measurement
WaveTrap measurements range Measurement
SurgeArrester measurements range Measurement
PostLineSensor measurements range Measurement
PotentialTransformer measurements range Measurement
FaultIndicator measurements range Measurement
CurrentRelay measurements range Measurement
SynchrocheckRelay measurements range Measurement
EquivalentShunt measurements range Measurement
EquivalentBranch measurements range Measurement
DCLineSegment measurements range Measurement
DCBreaker measurements range Measurement
DCSwitch measurements range Measurement
DCBusbar measurements range Measurement
DCDisconnector measurements range Measurement
DCGround measurements range Measurement
DCShunt measurements range Measurement
VsConverter measurements range Measurement
CsConverter measurements range Measurement
DCChopper measurements range Measurement
DCSeriesDevice measurements range Measurement
IPAccessPoint measurements range Measurement
TCPAccessPoint measurements range Measurement
ISOUpperLayer measurements range Measurement
Zone measurements range Measurement
Facility measurements range Measurement
Streetlight measurements range Measurement
Pole measurements range Measurement
FACTSDevice measurements range Measurement
Joint measurements range Measurement
Cabinet measurements range Measurement
ComMedia measurements range Measurement
Vehicle measurements range Measurement
MaintenanceLocation measurements range Measurement
InternalLocation measurements range Measurement
Tool measurements range Measurement
ShuntCompensatorControl measurements range Measurement
SVC measurements range Measurement
ComModule measurements range Measurement
UndergroundStructure measurements range Measurement
Tower measurements range Measurement
MktControlArea measurements range Measurement
MktShuntCompensator measurements range Measurement
MktSwitch measurements range Measurement
MktTapChanger measurements range Measurement
RegisteredDistributedResource measurements range Measurement
MktConductingEquipment measurements range Measurement

Identifier and Mapping Information

Schema Source

  • from schema: https://cim.ucaiug.io/ns#TC57CIM

Mappings

Mapping Type Mapped Value
self cim:Measurement
native cim:Measurement

LinkML Source

Direct

name: Measurement
description: "A Measurement represents any measured, calculated or non-measured non-calculated\
  \ quantity. Any piece of equipment may contain Measurements, e.g. a substation may\
  \ have temperature measurements and door open indications, a transformer may have\
  \ oil temperature and tank pressure measurements, a bay may contain a number of\
  \ power flow measurements and a Breaker may contain a switch status measurement.\
  \ \r\nThe PSR - Measurement association is intended to capture this use of Measurement\
  \ and is included in the naming hierarchy based on EquipmentContainer. The naming\
  \ hierarchy typically has Measurements as leaves, e.g. Substation-VoltageLevel-Bay-Switch-Measurement.\r\
  \nSome Measurements represent quantities related to a particular sensor location\
  \ in the network, e.g. a voltage transformer (VT) or potential transformer (PT)\
  \ at a busbar or a current transformer (CT) at the bar between a breaker and an\
  \ isolator. The sensing position is not captured in the PSR - Measurement association.\
  \ Instead it is captured by the Measurement - Terminal association that is used\
  \ to define the sensing location in the network topology. The location is defined\
  \ by the connection of the Terminal to ConductingEquipment. \r\nIf both a Terminal\
  \ and PSR are associated, and the PSR is of type ConductingEquipment, the associated\
  \ Terminal should belong to that ConductingEquipment instance.\r\nWhen the sensor\
  \ location is needed both Measurement-PSR and Measurement-Terminal are used. The\
  \ Measurement-Terminal association is never used alone."
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
is_a: IdentifiedObject
attributes:
  measurement_type:
    name: measurement_type
    description: "Specifies the type of measurement.  For example, this specifies\
      \ if the measurement represents an indoor temperature, outdoor temperature,\
      \ bus voltage, line flow, etc.\r\nWhen the measurementType is set to \"Specialization\"\
      , the type of Measurement is defined in more detail by the specialized class\
      \ which inherits from Measurement.\r\n\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Measurement.measurementType
    multivalued: false
    domain_of:
    - Measurement
    range: string
    required: false
  phases:
    name: phases
    description: "Indicates to which phases the measurement applies and avoids the\
      \ need to use 'measurementType' to also encode phase information (which would\
      \ explode the types). The phase information in Measurement, along with 'measurementType'\
      \ and 'phases' uniquely defines a Measurement for a device, based on normal\
      \ network phase. Their meaning will not change when the computed energizing\
      \ phasing is changed due to jumpers or other reasons.\r\nIf the attribute is\
      \ missing three phases (ABC) shall be assumed."
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:Measurement.phases
    multivalued: false
    domain_of:
    - Terminal
    - Measurement
    - SwitchingAction
    - Fault
    - TransformerTankEnd
    - ReadingType
    range: PhaseCode
    required: false
  unit_multiplier:
    name: unit_multiplier
    description: The unit multiplier of the measured quantity.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Measurement.unitMultiplier
    multivalued: false
    domain_of:
    - Measurement
    - ProtectionEquipment
    - Control
    range: UnitMultiplier
    required: false
  unit_symbol:
    name: unit_symbol
    description: The unit of measure of the measured quantity.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Measurement.unitSymbol
    multivalued: false
    domain_of:
    - Measurement
    - ProtectionEquipment
    - Control
    - ResourceCapacity
    range: UnitSymbol
    required: false
  terminal:
    name: terminal
    description: One or more measurements may be associated with a terminal in the
      network.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:Measurement.Terminal
    multivalued: false
    domain_of:
    - BusNameMarker
    - OperationalLimitSet
    - TopologicalNode
    - TransformerEnd
    - Measurement
    - Bushing
    - TieFlow
    - SvPowerFlow
    - RegulatingControl
    - RemoteInputSignal
    - BranchGroupTerminal
    - AuxiliaryEquipment
    - EquipmentFault
    - PinTerminal
    range: ACDCTerminal
    required: false
  protective_action_adjustment:
    name: protective_action_adjustment
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Measurement.ProtectiveActionAdjustment
    multivalued: true
    domain_of:
    - Measurement
    - ConductingEquipment
    - DCConductingEquipment
    range: ProtectiveActionAdjustment
    required: false
  calculation_method_hierarchy:
    name: calculation_method_hierarchy
    description: Calculation method hierarchy which applies to this analog.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:Measurement.CalculationMethodHierarchy
    multivalued: false
    domain_of:
    - MeasurementValue
    - CalculationMethodOrder
    - Measurement
    range: CalculationMethodHierarchy
    required: false
  power_system_resource:
    name: power_system_resource
    description: The power system resource that contains the measurement.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:Measurement.PowerSystemResource
    multivalued: false
    domain_of:
    - ReportingGroup
    - Measurement
    - ConfigurationEvent
    - Control
    - OperationalTag
    - OperatingShare
    - VerificationAction
    - GenericAction
    - PSREvent
    range: PowerSystemResource
    required: false
  pin_measurement:
    name: pin_measurement
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Measurement.PinMeasurement
    multivalued: true
    domain_of:
    - Measurement
    - MeasurementCalculator
    range: PinMeasurement
    required: false
  measurement_calculator_input:
    name: measurement_calculator_input
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Measurement.MeasurementCalculatorInput
    multivalued: true
    domain_of:
    - Measurement
    - MeasurementCalculator
    range: MeasurementCalculatorInput
    required: false
  asset:
    name: asset
    description: Asset that has a measurement
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:Measurement.Asset
    multivalued: false
    domain_of:
    - FinancialInfo
    - Incident
    - ProductAssetModel
    - Measurement
    - AssetDeployment
    - ProcedureDataSet
    - Reconditioning
    - Medium
    - ServiceLocation
    - AssetFunction
    - AnalyticScore
    - Analytic
    - AssetGroup
    - OperationalTag
    - Ownership
    - ErpItemMaster
    - ErpInventory
    range: Asset
    required: false
  measurement_action:
    name: measurement_action
    description: The measurement action that is performed on the measurement
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Measurement.MeasurementAction
    multivalued: false
    domain_of:
    - Measurement
    range: MeasurementAction
    required: false
  locations:
    name: locations
    description: Location of this measurement.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:Measurement.Locations
    multivalued: true
    domain_of:
    - LandProperty
    - Measurement
    - OldCrew
    - Route
    - AssetLocationHazard
    - CoordinateSystem
    range: Location
    required: false
  procedures:
    name: procedures
    description: Measurements are specified in types of documents, such as procedures.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:Measurement.Procedures
    multivalued: true
    domain_of:
    - Asset
    - CompatibleUnit
    - Measurement
    - Limit
    range: Procedure
    required: false
class_uri: cim:Measurement

Induced

name: Measurement
description: "A Measurement represents any measured, calculated or non-measured non-calculated\
  \ quantity. Any piece of equipment may contain Measurements, e.g. a substation may\
  \ have temperature measurements and door open indications, a transformer may have\
  \ oil temperature and tank pressure measurements, a bay may contain a number of\
  \ power flow measurements and a Breaker may contain a switch status measurement.\
  \ \r\nThe PSR - Measurement association is intended to capture this use of Measurement\
  \ and is included in the naming hierarchy based on EquipmentContainer. The naming\
  \ hierarchy typically has Measurements as leaves, e.g. Substation-VoltageLevel-Bay-Switch-Measurement.\r\
  \nSome Measurements represent quantities related to a particular sensor location\
  \ in the network, e.g. a voltage transformer (VT) or potential transformer (PT)\
  \ at a busbar or a current transformer (CT) at the bar between a breaker and an\
  \ isolator. The sensing position is not captured in the PSR - Measurement association.\
  \ Instead it is captured by the Measurement - Terminal association that is used\
  \ to define the sensing location in the network topology. The location is defined\
  \ by the connection of the Terminal to ConductingEquipment. \r\nIf both a Terminal\
  \ and PSR are associated, and the PSR is of type ConductingEquipment, the associated\
  \ Terminal should belong to that ConductingEquipment instance.\r\nWhen the sensor\
  \ location is needed both Measurement-PSR and Measurement-Terminal are used. The\
  \ Measurement-Terminal association is never used alone."
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
is_a: IdentifiedObject
attributes:
  measurement_type:
    name: measurement_type
    description: "Specifies the type of measurement.  For example, this specifies\
      \ if the measurement represents an indoor temperature, outdoor temperature,\
      \ bus voltage, line flow, etc.\r\nWhen the measurementType is set to \"Specialization\"\
      , the type of Measurement is defined in more detail by the specialized class\
      \ which inherits from Measurement.\r\n\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Measurement.measurementType
    multivalued: false
    alias: measurement_type
    owner: Measurement
    domain_of:
    - Measurement
    range: string
    required: false
  phases:
    name: phases
    description: "Indicates to which phases the measurement applies and avoids the\
      \ need to use 'measurementType' to also encode phase information (which would\
      \ explode the types). The phase information in Measurement, along with 'measurementType'\
      \ and 'phases' uniquely defines a Measurement for a device, based on normal\
      \ network phase. Their meaning will not change when the computed energizing\
      \ phasing is changed due to jumpers or other reasons.\r\nIf the attribute is\
      \ missing three phases (ABC) shall be assumed."
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:Measurement.phases
    multivalued: false
    alias: phases
    owner: Measurement
    domain_of:
    - Terminal
    - Measurement
    - SwitchingAction
    - Fault
    - TransformerTankEnd
    - ReadingType
    range: PhaseCode
    required: false
  unit_multiplier:
    name: unit_multiplier
    description: The unit multiplier of the measured quantity.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Measurement.unitMultiplier
    multivalued: false
    alias: unit_multiplier
    owner: Measurement
    domain_of:
    - Measurement
    - ProtectionEquipment
    - Control
    range: UnitMultiplier
    required: false
  unit_symbol:
    name: unit_symbol
    description: The unit of measure of the measured quantity.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Measurement.unitSymbol
    multivalued: false
    alias: unit_symbol
    owner: Measurement
    domain_of:
    - Measurement
    - ProtectionEquipment
    - Control
    - ResourceCapacity
    range: UnitSymbol
    required: false
  terminal:
    name: terminal
    description: One or more measurements may be associated with a terminal in the
      network.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:Measurement.Terminal
    multivalued: false
    alias: terminal
    owner: Measurement
    domain_of:
    - BusNameMarker
    - OperationalLimitSet
    - TopologicalNode
    - TransformerEnd
    - Measurement
    - Bushing
    - TieFlow
    - SvPowerFlow
    - RegulatingControl
    - RemoteInputSignal
    - BranchGroupTerminal
    - AuxiliaryEquipment
    - EquipmentFault
    - PinTerminal
    range: ACDCTerminal
    required: false
  protective_action_adjustment:
    name: protective_action_adjustment
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Measurement.ProtectiveActionAdjustment
    multivalued: true
    alias: protective_action_adjustment
    owner: Measurement
    domain_of:
    - Measurement
    - ConductingEquipment
    - DCConductingEquipment
    range: ProtectiveActionAdjustment
    required: false
  calculation_method_hierarchy:
    name: calculation_method_hierarchy
    description: Calculation method hierarchy which applies to this analog.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:Measurement.CalculationMethodHierarchy
    multivalued: false
    alias: calculation_method_hierarchy
    owner: Measurement
    domain_of:
    - MeasurementValue
    - CalculationMethodOrder
    - Measurement
    range: CalculationMethodHierarchy
    required: false
  power_system_resource:
    name: power_system_resource
    description: The power system resource that contains the measurement.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:Measurement.PowerSystemResource
    multivalued: false
    alias: power_system_resource
    owner: Measurement
    domain_of:
    - ReportingGroup
    - Measurement
    - ConfigurationEvent
    - Control
    - OperationalTag
    - OperatingShare
    - VerificationAction
    - GenericAction
    - PSREvent
    range: PowerSystemResource
    required: false
  pin_measurement:
    name: pin_measurement
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Measurement.PinMeasurement
    multivalued: true
    alias: pin_measurement
    owner: Measurement
    domain_of:
    - Measurement
    - MeasurementCalculator
    range: PinMeasurement
    required: false
  measurement_calculator_input:
    name: measurement_calculator_input
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Measurement.MeasurementCalculatorInput
    multivalued: true
    alias: measurement_calculator_input
    owner: Measurement
    domain_of:
    - Measurement
    - MeasurementCalculator
    range: MeasurementCalculatorInput
    required: false
  asset:
    name: asset
    description: Asset that has a measurement
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:Measurement.Asset
    multivalued: false
    alias: asset
    owner: Measurement
    domain_of:
    - FinancialInfo
    - Incident
    - ProductAssetModel
    - Measurement
    - AssetDeployment
    - ProcedureDataSet
    - Reconditioning
    - Medium
    - ServiceLocation
    - AssetFunction
    - AnalyticScore
    - Analytic
    - AssetGroup
    - OperationalTag
    - Ownership
    - ErpItemMaster
    - ErpInventory
    range: Asset
    required: false
  measurement_action:
    name: measurement_action
    description: The measurement action that is performed on the measurement
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Measurement.MeasurementAction
    multivalued: false
    alias: measurement_action
    owner: Measurement
    domain_of:
    - Measurement
    range: MeasurementAction
    required: false
  locations:
    name: locations
    description: Location of this measurement.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:Measurement.Locations
    multivalued: true
    alias: locations
    owner: Measurement
    domain_of:
    - LandProperty
    - Measurement
    - OldCrew
    - Route
    - AssetLocationHazard
    - CoordinateSystem
    range: Location
    required: false
  procedures:
    name: procedures
    description: Measurements are specified in types of documents, such as procedures.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:Measurement.Procedures
    multivalued: true
    alias: procedures
    owner: Measurement
    domain_of:
    - Asset
    - CompatibleUnit
    - Measurement
    - Limit
    range: Procedure
    required: false
  alias_name:
    name: alias_name
    description: "The aliasName is free text human readable name of the object alternative\
      \ to IdentifiedObject.name. It may be non unique and may not correlate to a\
      \ naming hierarchy.\r\nThe attribute aliasName is retained because of backwards\
      \ compatibility between CIM relases. It is however recommended to replace aliasName\
      \ with the Name class as aliasName is planned for retirement at a future time.\r\
      \n\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.aliasName
    multivalued: false
    alias: alias_name
    owner: Measurement
    domain_of:
    - IdentifiedObject
    range: string
    required: false
  description:
    name: description
    description: The description is a free human readable text describing or naming
      the object. It may be non unique and may not correlate to a naming hierarchy.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.description
    multivalued: false
    alias: description
    owner: Measurement
    domain_of:
    - IdentifiedObject
    - NameType
    - NameTypeAuthority
    - DataSet
    - SwitchingStepGroup
    - AreaReserveSpec
    range: string
    required: false
  m_rid:
    name: m_rid
    description: "Master resource identifier issued by a model authority. The mRID\
      \ is unique within an exchange context. Global uniqueness is easily achieved\
      \ by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is\
      \ strongly recommended.\r\nFor CIMXML data files in RDF syntax conforming to\
      \ IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify\
      \ CIM object elements."
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.mRID
    multivalued: false
    alias: m_rid
    owner: Measurement
    domain_of:
    - IdentifiedObject
    - DataSet
    range: string
    required: false
  diagram_objects:
    name: diagram_objects
    description: The diagram objects that are associated with the domain object.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.DiagramObjects
    multivalued: true
    alias: diagram_objects
    owner: Measurement
    domain_of:
    - IdentifiedObject
    range: DiagramObject
    required: false
  instance_set:
    name: instance_set
    description: Dataset containing the data objects.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.InstanceSet
    multivalued: false
    alias: instance_set
    owner: Measurement
    domain_of:
    - IdentifiedObject
    range: InstanceSet
    required: true
  names:
    name: names
    description: All names of this identified object.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.Names
    multivalued: true
    alias: names
    owner: Measurement
    domain_of:
    - IdentifiedObject
    - NameType
    range: Name
    required: false
  properties_cimdata_object:
    name: properties_cimdata_object
    description: The single CIM data object in the appropriate dataset context.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.PropertiesCIMDataObject
    multivalued: false
    alias: properties_cimdata_object
    owner: Measurement
    domain_of:
    - IdentifiedObject
    range: ChangeSetMember
    required: false
  targeting_cimdata_object:
    name: targeting_cimdata_object
    description: Data objects registered.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.TargetingCIMDataObject
    multivalued: true
    alias: targeting_cimdata_object
    owner: Measurement
    domain_of:
    - IdentifiedObject
    range: ChangeSetMember
    required: false
class_uri: cim:Measurement