Class: IncrementalHeatRateCurve
Relationship between unit incremental heat rate in (delta energy/time) per (delta active power) and unit output in active power. The IHR curve represents the slope of the HeatInputCurve. Note that the "incremental heat rate" and the "heat rate" have the same engineering units.
URI: cim:IncrementalHeatRateCurve
classDiagram
class IncrementalHeatRateCurve
Curve <|-- IncrementalHeatRateCurve
IncrementalHeatRateCurve : alias_name
IncrementalHeatRateCurve : curve_datas
IncrementalHeatRateCurve --> CurveData : curve_datas
IncrementalHeatRateCurve : curve_style
IncrementalHeatRateCurve --> CurveStyle : curve_style
IncrementalHeatRateCurve : description
IncrementalHeatRateCurve : diagram_objects
IncrementalHeatRateCurve --> DiagramObject : diagram_objects
IncrementalHeatRateCurve : instance_set
IncrementalHeatRateCurve --> InstanceSet : instance_set
IncrementalHeatRateCurve : is_net_gross_p
IncrementalHeatRateCurve : m_rid
IncrementalHeatRateCurve : names
IncrementalHeatRateCurve --> Name : names
IncrementalHeatRateCurve : properties_cimdata_object
IncrementalHeatRateCurve --> ChangeSetMember : properties_cimdata_object
IncrementalHeatRateCurve : targeting_cimdata_object
IncrementalHeatRateCurve --> ChangeSetMember : targeting_cimdata_object
IncrementalHeatRateCurve : thermal_generating_unit
IncrementalHeatRateCurve --> ThermalGeneratingUnit : thermal_generating_unit
IncrementalHeatRateCurve : x_multiplier
IncrementalHeatRateCurve --> UnitMultiplier : x_multiplier
IncrementalHeatRateCurve : x_unit
IncrementalHeatRateCurve --> UnitSymbol : x_unit
IncrementalHeatRateCurve : y_multiplier
IncrementalHeatRateCurve --> UnitMultiplier : y_multiplier
IncrementalHeatRateCurve : y_unit
IncrementalHeatRateCurve --> UnitSymbol : y_unit
Inheritance
- IdentifiedObject
- Curve
- IncrementalHeatRateCurve
- Curve
Slots
| Name | Cardinality and Range | Description | Inheritance |
|---|---|---|---|
| is_net_gross_p | 0..1 Boolean |
Flag is set to true when output is expressed in net active power | direct |
| thermal_generating_unit | 1..1 ThermalGeneratingUnit |
A thermal generating unit may have an incremental heat rate curve | direct |
| curve_style | 0..1 CurveStyle |
The style or shape of the curve | Curve |
| x_multiplier | 0..1 UnitMultiplier |
Multiplier for X-axis | Curve |
| x_unit | 0..1 UnitSymbol |
The X-axis units of measure | Curve |
| y_multiplier | 0..1 UnitMultiplier |
Multiplier for Y3-axis | Curve |
| y_unit | 0..1 UnitSymbol |
The Y3-axis units of measure | Curve |
| curve_datas | 0..* CurveData |
The point data values that define this curve | Curve |
| alias_name | 0..1 String |
The aliasName is free text human readable name of the object alternative to I... | IdentifiedObject |
| description | 0..1 String |
The description is a free human readable text describing or naming the object | IdentifiedObject |
| m_rid | 0..1 String |
Master resource identifier issued by a model authority | IdentifiedObject |
| diagram_objects | 0..* DiagramObject |
The diagram objects that are associated with the domain object | IdentifiedObject |
| instance_set | 1..1 InstanceSet |
Dataset containing the data objects | IdentifiedObject |
| names | 0..* Name |
All names of this identified object | IdentifiedObject |
| properties_cimdata_object | 0..1 ChangeSetMember |
The single CIM data object in the appropriate dataset context | IdentifiedObject |
| targeting_cimdata_object | 0..* ChangeSetMember |
Data objects registered | IdentifiedObject |
Usages
| used by | used in | type | used |
|---|---|---|---|
| ThermalGeneratingUnit | incremental_heat_rate_curve | range | IncrementalHeatRateCurve |
| MktThermalGeneratingUnit | incremental_heat_rate_curve | range | IncrementalHeatRateCurve |
Identifier and Mapping Information
Schema Source
- from schema: https://cim.ucaiug.io/ns#TC57CIM
Mappings
| Mapping Type | Mapped Value |
|---|---|
| self | cim:IncrementalHeatRateCurve |
| native | cim:IncrementalHeatRateCurve |
LinkML Source
Direct
name: IncrementalHeatRateCurve
description: Relationship between unit incremental heat rate in (delta energy/time)
per (delta active power) and unit output in active power. The IHR curve represents
the slope of the HeatInputCurve. Note that the "incremental heat rate" and the "heat
rate" have the same engineering units.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
is_a: Curve
attributes:
is_net_gross_p:
name: is_net_gross_p
description: "Flag is set to true when output is expressed in net active power.\r\
\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:IncrementalHeatRateCurve.isNetGrossP
multivalued: false
domain_of:
- HeatRateCurve
- GenUnitOpCostCurve
- EmissionCurve
- IncrementalHeatRateCurve
- HeatInputCurve
range: boolean
required: false
thermal_generating_unit:
name: thermal_generating_unit
description: A thermal generating unit may have an incremental heat rate curve.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:IncrementalHeatRateCurve.ThermalGeneratingUnit
multivalued: false
domain_of:
- HeatRateCurve
- FuelAllocationSchedule
- FossilFuel
- StartupModel
- EmissionCurve
- ShutdownCurve
- IncrementalHeatRateCurve
- CAESPlant
- EmissionAccount
- HeatInputCurve
range: ThermalGeneratingUnit
required: true
class_uri: cim:IncrementalHeatRateCurve
Induced
name: IncrementalHeatRateCurve
description: Relationship between unit incremental heat rate in (delta energy/time)
per (delta active power) and unit output in active power. The IHR curve represents
the slope of the HeatInputCurve. Note that the "incremental heat rate" and the "heat
rate" have the same engineering units.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
is_a: Curve
attributes:
is_net_gross_p:
name: is_net_gross_p
description: "Flag is set to true when output is expressed in net active power.\r\
\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:IncrementalHeatRateCurve.isNetGrossP
multivalued: false
alias: is_net_gross_p
owner: IncrementalHeatRateCurve
domain_of:
- HeatRateCurve
- GenUnitOpCostCurve
- EmissionCurve
- IncrementalHeatRateCurve
- HeatInputCurve
range: boolean
required: false
thermal_generating_unit:
name: thermal_generating_unit
description: A thermal generating unit may have an incremental heat rate curve.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:IncrementalHeatRateCurve.ThermalGeneratingUnit
multivalued: false
alias: thermal_generating_unit
owner: IncrementalHeatRateCurve
domain_of:
- HeatRateCurve
- FuelAllocationSchedule
- FossilFuel
- StartupModel
- EmissionCurve
- ShutdownCurve
- IncrementalHeatRateCurve
- CAESPlant
- EmissionAccount
- HeatInputCurve
range: ThermalGeneratingUnit
required: true
curve_style:
name: curve_style
description: The style or shape of the curve.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Curve.curveStyle
multivalued: false
alias: curve_style
owner: IncrementalHeatRateCurve
domain_of:
- Curve
range: CurveStyle
required: false
x_multiplier:
name: x_multiplier
description: Multiplier for X-axis.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Curve.xMultiplier
multivalued: false
alias: x_multiplier
owner: IncrementalHeatRateCurve
domain_of:
- Curve
range: UnitMultiplier
required: false
x_unit:
name: x_unit
description: The X-axis units of measure.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Curve.xUnit
multivalued: false
alias: x_unit
owner: IncrementalHeatRateCurve
domain_of:
- Curve
range: UnitSymbol
required: false
y_multiplier:
name: y_multiplier
description: Multiplier for Y3-axis.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Curve.y3Multiplier
multivalued: false
alias: y_multiplier
owner: IncrementalHeatRateCurve
domain_of:
- Curve
- DERMonitorableParameter
range: UnitMultiplier
required: false
y_unit:
name: y_unit
description: The Y3-axis units of measure.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Curve.y3Unit
multivalued: false
alias: y_unit
owner: IncrementalHeatRateCurve
domain_of:
- Curve
- DERMonitorableParameter
range: UnitSymbol
required: false
curve_datas:
name: curve_datas
description: The point data values that define this curve.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Curve.CurveDatas
multivalued: true
alias: curve_datas
owner: IncrementalHeatRateCurve
domain_of:
- Curve
range: CurveData
required: false
alias_name:
name: alias_name
description: "The aliasName is free text human readable name of the object alternative\
\ to IdentifiedObject.name. It may be non unique and may not correlate to a\
\ naming hierarchy.\r\nThe attribute aliasName is retained because of backwards\
\ compatibility between CIM relases. It is however recommended to replace aliasName\
\ with the Name class as aliasName is planned for retirement at a future time.\r\
\n\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.aliasName
multivalued: false
alias: alias_name
owner: IncrementalHeatRateCurve
domain_of:
- IdentifiedObject
range: string
required: false
description:
name: description
description: The description is a free human readable text describing or naming
the object. It may be non unique and may not correlate to a naming hierarchy.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.description
multivalued: false
alias: description
owner: IncrementalHeatRateCurve
domain_of:
- IdentifiedObject
- NameType
- NameTypeAuthority
- DataSet
- SwitchingStepGroup
- AreaReserveSpec
range: string
required: false
m_rid:
name: m_rid
description: "Master resource identifier issued by a model authority. The mRID\
\ is unique within an exchange context. Global uniqueness is easily achieved\
\ by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is\
\ strongly recommended.\r\nFor CIMXML data files in RDF syntax conforming to\
\ IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify\
\ CIM object elements."
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.mRID
multivalued: false
alias: m_rid
owner: IncrementalHeatRateCurve
domain_of:
- IdentifiedObject
- DataSet
range: string
required: false
diagram_objects:
name: diagram_objects
description: The diagram objects that are associated with the domain object.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.DiagramObjects
multivalued: true
alias: diagram_objects
owner: IncrementalHeatRateCurve
domain_of:
- IdentifiedObject
range: DiagramObject
required: false
instance_set:
name: instance_set
description: Dataset containing the data objects.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.InstanceSet
multivalued: false
alias: instance_set
owner: IncrementalHeatRateCurve
domain_of:
- IdentifiedObject
range: InstanceSet
required: true
names:
name: names
description: All names of this identified object.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.Names
multivalued: true
alias: names
owner: IncrementalHeatRateCurve
domain_of:
- IdentifiedObject
- NameType
range: Name
required: false
properties_cimdata_object:
name: properties_cimdata_object
description: The single CIM data object in the appropriate dataset context.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.PropertiesCIMDataObject
multivalued: false
alias: properties_cimdata_object
owner: IncrementalHeatRateCurve
domain_of:
- IdentifiedObject
range: ChangeSetMember
required: false
targeting_cimdata_object:
name: targeting_cimdata_object
description: Data objects registered.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.TargetingCIMDataObject
multivalued: true
alias: targeting_cimdata_object
owner: IncrementalHeatRateCurve
domain_of:
- IdentifiedObject
range: ChangeSetMember
required: false
class_uri: cim:IncrementalHeatRateCurve