Skip to content

Class: GroundAction

Action on ground as a switching step.

URI: cim:GroundAction

 classDiagram
    class GroundAction
      SwitchingAction <|-- GroundAction

      GroundAction : alias_name

      GroundAction : along_acline_segment

          GroundAction --> ACLineSegment : along_acline_segment

      GroundAction : crew

          GroundAction --> Crew : crew

      GroundAction : description

      GroundAction : diagram_objects

          GroundAction --> DiagramObject : diagram_objects

      GroundAction : executed_date_time

      GroundAction : ground

          GroundAction --> Ground : ground

      GroundAction : grounded_equipment

          GroundAction --> ConductingEquipment : grounded_equipment

      GroundAction : instance_set

          GroundAction --> InstanceSet : instance_set

      GroundAction : issued_date_time

      GroundAction : kind

          GroundAction --> TempEquipActionKind : kind

      GroundAction : m_rid

      GroundAction : names

          GroundAction --> Name : names

      GroundAction : operator

          GroundAction --> Operator : operator

      GroundAction : phases

          GroundAction --> PhaseCode : phases

      GroundAction : planned_date_time

      GroundAction : properties_cimdata_object

          GroundAction --> ChangeSetMember : properties_cimdata_object

      GroundAction : switching_event

          GroundAction --> SwitchingEvent : switching_event

      GroundAction : switching_plan

          GroundAction --> SwitchingPlan : switching_plan

      GroundAction : switching_step

          GroundAction --> SwitchingStep : switching_step

      GroundAction : targeting_cimdata_object

          GroundAction --> ChangeSetMember : targeting_cimdata_object

Inheritance

Slots

Name Cardinality and Range Description Inheritance
kind 0..1
TempEquipActionKind
Switching action to perform direct
along_acline_segment 0..1
ACLineSegment
The line segment that this ground action will affect direct
ground 0..1
Ground
Ground on which this action is taken direct
grounded_equipment 0..1
ConductingEquipment
Equipment being grounded with this operation direct
executed_date_time 0..1
date
Actual date and time of this switching step SwitchingAction
issued_date_time 0..1
date
Date and time when the crew was given the instruction to execute the action; ... SwitchingAction
phases 0..1
PhaseCode
Phases of the Switching Action SwitchingAction
planned_date_time 0..1
date
Planned date and time of this switching step SwitchingAction
switching_plan 0..1
SwitchingPlan
The switching plan that is associated with the switching actions SwitchingAction
operator 0..1
Operator
Operator responsible for this switching step SwitchingAction
crew 0..*
Crew
The crew that is assigned to the switching action SwitchingAction
switching_event 0..1
SwitchingEvent
The switching event that the switching action is performed on SwitchingAction
switching_step 0..1
SwitchingStep
The switching step that is associated to the switching action SwitchingAction
alias_name 0..1
String
The aliasName is free text human readable name of the object alternative to I... IdentifiedObject
description 0..1
String
The description is a free human readable text describing or naming the object IdentifiedObject
m_rid 0..1
String
Master resource identifier issued by a model authority IdentifiedObject
diagram_objects 0..*
DiagramObject
The diagram objects that are associated with the domain object IdentifiedObject
instance_set 1..1
InstanceSet
Dataset containing the data objects IdentifiedObject
names 0..*
Name
All names of this identified object IdentifiedObject
properties_cimdata_object 0..1
ChangeSetMember
The single CIM data object in the appropriate dataset context IdentifiedObject
targeting_cimdata_object 0..*
ChangeSetMember
Data objects registered IdentifiedObject

Usages

used by used in type used
ProtectedSwitch grounding_action range GroundAction
Switch grounding_action range GroundAction
ConductingEquipment grounding_action range GroundAction
PowerTransformer grounding_action range GroundAction
Clamp grounding_action range GroundAction
ACLineSegment line_grounding_action range GroundAction
ACLineSegment grounding_action range GroundAction
Conductor grounding_action range GroundAction
Cut grounding_action range GroundAction
Ground ground_action range GroundAction
Ground grounding_action range GroundAction
Jumper grounding_action range GroundAction
EnergyConnection grounding_action range GroundAction
RotatingMachine grounding_action range GroundAction
RegulatingCondEq grounding_action range GroundAction
BusbarSection grounding_action range GroundAction
Connector grounding_action range GroundAction
SynchronousMachine grounding_action range GroundAction
EquivalentInjection grounding_action range GroundAction
EquivalentEquipment grounding_action range GroundAction
PowerElectronicsConnection grounding_action range GroundAction
AsynchronousMachine grounding_action range GroundAction
MktPowerTransformer grounding_action range GroundAction
MktSeriesCompensator grounding_action range GroundAction
SeriesCompensator grounding_action range GroundAction
MktACLineSegment line_grounding_action range GroundAction
MktACLineSegment grounding_action range GroundAction
ACDCConverter grounding_action range GroundAction
ShuntCompensator grounding_action range GroundAction
Disconnector grounding_action range GroundAction
EnergyConsumer grounding_action range GroundAction
Breaker grounding_action range GroundAction
GroundDisconnector grounding_action range GroundAction
Fuse grounding_action range GroundAction
PetersenCoil grounding_action range GroundAction
EarthFaultCompensator grounding_action range GroundAction
GroundingImpedance grounding_action range GroundAction
Recloser grounding_action range GroundAction
Sectionaliser grounding_action range GroundAction
EnergySource grounding_action range GroundAction
StaticVarCompensator grounding_action range GroundAction
Junction grounding_action range GroundAction
FrequencyConverter grounding_action range GroundAction
LoadBreakSwitch grounding_action range GroundAction
ExternalNetworkInjection grounding_action range GroundAction
LinearShuntCompensator grounding_action range GroundAction
NonlinearShuntCompensator grounding_action range GroundAction
WireSegment grounding_action range GroundAction
DisconnectingCircuitBreaker grounding_action range GroundAction
ConformLoad grounding_action range GroundAction
NonConformLoad grounding_action range GroundAction
StationSupply grounding_action range GroundAction
EquivalentShunt grounding_action range GroundAction
EquivalentBranch grounding_action range GroundAction
VsConverter grounding_action range GroundAction
CsConverter grounding_action range GroundAction
SVC grounding_action range GroundAction
MktShuntCompensator grounding_action range GroundAction
MktSwitch grounding_action range GroundAction
MktConductingEquipment grounding_action range GroundAction

Identifier and Mapping Information

Schema Source

  • from schema: https://cim.ucaiug.io/ns#TC57CIM

Mappings

Mapping Type Mapped Value
self cim:GroundAction
native cim:GroundAction

LinkML Source

Direct

name: GroundAction
description: Action on ground as a switching step.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
is_a: SwitchingAction
attributes:
  kind:
    name: kind
    description: Switching action to perform.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:GroundAction.kind
    multivalued: false
    domain_of:
    - Asset
    - Customer
    - BaseWork
    - WorkTimeSchedule
    - CustomerBillingInfo
    - ErpInvoiceLineItem
    - CatalogAssetType
    - Design
    - ConditionFactor
    - LandProperty
    - Seal
    - Gate
    - JumperAction
    - RevisionHistory
    - SwitchAction
    - Fault
    - ServiceCategory
    - Transaction
    - Procedure
    - Medium
    - Tender
    - Cheque
    - Charge
    - ServiceRequest
    - MeterMultiplier
    - StructureSupport
    - CutAction
    - GroundAction
    - ClampAction
    - ProtectiveActionAdjustment
    - RemedialActionScheme
    - MeasurementCalculator
    - ErpInvoice
    - ServiceSupplier
    - EnergyTypeReference
    - CRROrgRole
    - MarketInvoice
    - MarketInvoiceLineItem
    - EnvironmentalLocationType
    - EnvironmentalDiscrete
    - ServiceMultiplier
    - AssetLocationHazard
    - Analytic
    - AssetGroup
    - TagAction
    - PinBranchGroup
    - PinTerminal
    - PinEquipment
    - ClearanceAction
    - PSREvent
    - ShuntCompensatorAction
    - EnergyConsumerAction
    - EnergySourceAction
    - Zone
    - OilAnalysisMoistureAnalog
    - AssetStringMeasurement
    - InspectionAnalog
    - AssetTemperaturePressureAnalog
    - OilAnalysisFluidDiscrete
    - InspectionDiscrete
    - OilAnalysisPCBDiscrete
    - OilAnalysisFluidAnalog
    - OilAnalysisGasAnalog
    - OilAnalysisPCBAnalog
    - OilAnalysisParticleDiscrete
    - OilAnalysisMetalsAnalog
    - OilAnalysisParticleAnalog
    - OilAnalysisPaperAnalog
    - CompositeSwitchInfo
    - Facility
    - RiskScore
    - FACTSDevice
    - SimpleEndDeviceFunction
    - UndergroundStructure
    - RelativeDisplacement
    - CloudCondition
    - GeosphericAnalog
    - HydrosphericAnalog
    - AtmosphericAnalog
    - SpaceAnalog
    range: TempEquipActionKind
    required: false
  along_acline_segment:
    name: along_acline_segment
    description: The line segment that this ground action will affect. This is the
      only way to access relationship to clamp in case the ground needs to be placed
      along the line segment.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GroundAction.AlongACLineSegment
    multivalued: false
    domain_of:
    - GroundAction
    range: ACLineSegment
    required: false
  ground:
    name: ground
    description: Ground on which this action is taken.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GroundAction.Ground
    multivalued: false
    domain_of:
    - GroundAction
    range: Ground
    required: false
  grounded_equipment:
    name: grounded_equipment
    description: Equipment being grounded with this operation. In case of placing
      a ground anywhere along a line segment, you must use the clamp (to get the distance
      from one terminal), so use the explicit relation with line segment. In all other
      cases (including placing the ground at a line segment terminal), reference to
      one or more conducting equipment is sufficient.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GroundAction.GroundedEquipment
    multivalued: false
    domain_of:
    - GroundAction
    range: ConductingEquipment
    required: false
class_uri: cim:GroundAction

Induced

name: GroundAction
description: Action on ground as a switching step.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
is_a: SwitchingAction
attributes:
  kind:
    name: kind
    description: Switching action to perform.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:GroundAction.kind
    multivalued: false
    alias: kind
    owner: GroundAction
    domain_of:
    - Asset
    - Customer
    - BaseWork
    - WorkTimeSchedule
    - CustomerBillingInfo
    - ErpInvoiceLineItem
    - CatalogAssetType
    - Design
    - ConditionFactor
    - LandProperty
    - Seal
    - Gate
    - JumperAction
    - RevisionHistory
    - SwitchAction
    - Fault
    - ServiceCategory
    - Transaction
    - Procedure
    - Medium
    - Tender
    - Cheque
    - Charge
    - ServiceRequest
    - MeterMultiplier
    - StructureSupport
    - CutAction
    - GroundAction
    - ClampAction
    - ProtectiveActionAdjustment
    - RemedialActionScheme
    - MeasurementCalculator
    - ErpInvoice
    - ServiceSupplier
    - EnergyTypeReference
    - CRROrgRole
    - MarketInvoice
    - MarketInvoiceLineItem
    - EnvironmentalLocationType
    - EnvironmentalDiscrete
    - ServiceMultiplier
    - AssetLocationHazard
    - Analytic
    - AssetGroup
    - TagAction
    - PinBranchGroup
    - PinTerminal
    - PinEquipment
    - ClearanceAction
    - PSREvent
    - ShuntCompensatorAction
    - EnergyConsumerAction
    - EnergySourceAction
    - Zone
    - OilAnalysisMoistureAnalog
    - AssetStringMeasurement
    - InspectionAnalog
    - AssetTemperaturePressureAnalog
    - OilAnalysisFluidDiscrete
    - InspectionDiscrete
    - OilAnalysisPCBDiscrete
    - OilAnalysisFluidAnalog
    - OilAnalysisGasAnalog
    - OilAnalysisPCBAnalog
    - OilAnalysisParticleDiscrete
    - OilAnalysisMetalsAnalog
    - OilAnalysisParticleAnalog
    - OilAnalysisPaperAnalog
    - CompositeSwitchInfo
    - Facility
    - RiskScore
    - FACTSDevice
    - SimpleEndDeviceFunction
    - UndergroundStructure
    - RelativeDisplacement
    - CloudCondition
    - GeosphericAnalog
    - HydrosphericAnalog
    - AtmosphericAnalog
    - SpaceAnalog
    range: TempEquipActionKind
    required: false
  along_acline_segment:
    name: along_acline_segment
    description: The line segment that this ground action will affect. This is the
      only way to access relationship to clamp in case the ground needs to be placed
      along the line segment.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GroundAction.AlongACLineSegment
    multivalued: false
    alias: along_acline_segment
    owner: GroundAction
    domain_of:
    - GroundAction
    range: ACLineSegment
    required: false
  ground:
    name: ground
    description: Ground on which this action is taken.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GroundAction.Ground
    multivalued: false
    alias: ground
    owner: GroundAction
    domain_of:
    - GroundAction
    range: Ground
    required: false
  grounded_equipment:
    name: grounded_equipment
    description: Equipment being grounded with this operation. In case of placing
      a ground anywhere along a line segment, you must use the clamp (to get the distance
      from one terminal), so use the explicit relation with line segment. In all other
      cases (including placing the ground at a line segment terminal), reference to
      one or more conducting equipment is sufficient.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GroundAction.GroundedEquipment
    multivalued: false
    alias: grounded_equipment
    owner: GroundAction
    domain_of:
    - GroundAction
    range: ConductingEquipment
    required: false
  executed_date_time:
    name: executed_date_time
    description: Actual date and time of this switching step.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:SwitchingAction.executedDateTime
    multivalued: false
    alias: executed_date_time
    owner: GroundAction
    domain_of:
    - SwitchingAction
    range: date
    required: false
  issued_date_time:
    name: issued_date_time
    description: Date and time when the crew was given the instruction to execute
      the action; not applicable if the action is performed by operator remote control.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:SwitchingAction.issuedDateTime
    multivalued: false
    alias: issued_date_time
    owner: GroundAction
    domain_of:
    - SwitchingAction
    - SafetyDocument
    range: date
    required: false
  phases:
    name: phases
    description: Phases of the Switching Action
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:SwitchingAction.phases
    multivalued: false
    alias: phases
    owner: GroundAction
    domain_of:
    - Terminal
    - Measurement
    - SwitchingAction
    - Fault
    - TransformerTankEnd
    - ReadingType
    range: PhaseCode
    required: false
  planned_date_time:
    name: planned_date_time
    description: Planned date and time of this switching step.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:SwitchingAction.plannedDateTime
    multivalued: false
    alias: planned_date_time
    owner: GroundAction
    domain_of:
    - SwitchingAction
    range: date
    required: false
  switching_plan:
    name: switching_plan
    description: The switching plan that is associated with the switching actions.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:SwitchingAction.SwitchingPlan
    multivalued: false
    alias: switching_plan
    owner: GroundAction
    domain_of:
    - SwitchingPlanRequest
    - SwitchingOrder
    - WorkTask
    - SwitchingAction
    - SwitchingStepGroup
    - OutagePlan
    - PlannedOutageNotification
    - SafetyDocument
    range: SwitchingPlan
    required: false
  operator:
    name: operator
    description: Operator responsible for this switching step.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:SwitchingAction.Operator
    multivalued: false
    alias: operator
    owner: GroundAction
    domain_of:
    - SwitchingAction
    range: Operator
    required: false
  crew:
    name: crew
    description: The crew that is assigned to the switching action.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:SwitchingAction.Crew
    multivalued: true
    alias: crew
    owner: GroundAction
    domain_of:
    - Location
    - Capability
    - SwitchingAction
    - FieldDispatchHistory
    - Outage
    - WorkAsset
    - CrewMember
    range: Crew
    required: false
  switching_event:
    name: switching_event
    description: The switching event that the switching action is performed on
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:SwitchingAction.SwitchingEvent
    multivalued: false
    alias: switching_event
    owner: GroundAction
    domain_of:
    - SwitchingAction
    range: SwitchingEvent
    required: false
  switching_step:
    name: switching_step
    description: The switching step that is associated to the switching action.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:SwitchingAction.SwitchingStep
    multivalued: false
    alias: switching_step
    owner: GroundAction
    domain_of:
    - SwitchingAction
    - SwitchingStepGroup
    - RevisionHistory
    range: SwitchingStep
    required: false
  alias_name:
    name: alias_name
    description: "The aliasName is free text human readable name of the object alternative\
      \ to IdentifiedObject.name. It may be non unique and may not correlate to a\
      \ naming hierarchy.\r\nThe attribute aliasName is retained because of backwards\
      \ compatibility between CIM relases. It is however recommended to replace aliasName\
      \ with the Name class as aliasName is planned for retirement at a future time.\r\
      \n\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.aliasName
    multivalued: false
    alias: alias_name
    owner: GroundAction
    domain_of:
    - IdentifiedObject
    range: string
    required: false
  description:
    name: description
    description: The description is a free human readable text describing or naming
      the object. It may be non unique and may not correlate to a naming hierarchy.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.description
    multivalued: false
    alias: description
    owner: GroundAction
    domain_of:
    - IdentifiedObject
    - NameType
    - NameTypeAuthority
    - DataSet
    - SwitchingStepGroup
    - AreaReserveSpec
    range: string
    required: false
  m_rid:
    name: m_rid
    description: "Master resource identifier issued by a model authority. The mRID\
      \ is unique within an exchange context. Global uniqueness is easily achieved\
      \ by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is\
      \ strongly recommended.\r\nFor CIMXML data files in RDF syntax conforming to\
      \ IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify\
      \ CIM object elements."
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.mRID
    multivalued: false
    alias: m_rid
    owner: GroundAction
    domain_of:
    - IdentifiedObject
    - DataSet
    range: string
    required: false
  diagram_objects:
    name: diagram_objects
    description: The diagram objects that are associated with the domain object.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.DiagramObjects
    multivalued: true
    alias: diagram_objects
    owner: GroundAction
    domain_of:
    - IdentifiedObject
    range: DiagramObject
    required: false
  instance_set:
    name: instance_set
    description: Dataset containing the data objects.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.InstanceSet
    multivalued: false
    alias: instance_set
    owner: GroundAction
    domain_of:
    - IdentifiedObject
    range: InstanceSet
    required: true
  names:
    name: names
    description: All names of this identified object.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.Names
    multivalued: true
    alias: names
    owner: GroundAction
    domain_of:
    - IdentifiedObject
    - NameType
    range: Name
    required: false
  properties_cimdata_object:
    name: properties_cimdata_object
    description: The single CIM data object in the appropriate dataset context.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.PropertiesCIMDataObject
    multivalued: false
    alias: properties_cimdata_object
    owner: GroundAction
    domain_of:
    - IdentifiedObject
    range: ChangeSetMember
    required: false
  targeting_cimdata_object:
    name: targeting_cimdata_object
    description: Data objects registered.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.TargetingCIMDataObject
    multivalued: true
    alias: targeting_cimdata_object
    owner: GroundAction
    domain_of:
    - IdentifiedObject
    range: ChangeSetMember
    required: false
class_uri: cim:GroundAction