Skip to content

Class: GrossToNetActivePowerCurve

Relationship between the generating unit's gross active power output on the X-axis (measured at the terminals of the machine(s)) and the generating unit's net active power output on the Y-axis (based on utility-defined measurements at the power station). Station service loads, when modelled, should be treated as non-conforming bus loads. There may be more than one curve, depending on the auxiliary equipment that is in service.

URI: cim:GrossToNetActivePowerCurve

 classDiagram
    class GrossToNetActivePowerCurve
      Curve <|-- GrossToNetActivePowerCurve

      GrossToNetActivePowerCurve : alias_name

      GrossToNetActivePowerCurve : curve_datas

          GrossToNetActivePowerCurve --> CurveData : curve_datas

      GrossToNetActivePowerCurve : curve_style

          GrossToNetActivePowerCurve --> CurveStyle : curve_style

      GrossToNetActivePowerCurve : description

      GrossToNetActivePowerCurve : diagram_objects

          GrossToNetActivePowerCurve --> DiagramObject : diagram_objects

      GrossToNetActivePowerCurve : generating_unit

          GrossToNetActivePowerCurve --> GeneratingUnit : generating_unit

      GrossToNetActivePowerCurve : instance_set

          GrossToNetActivePowerCurve --> InstanceSet : instance_set

      GrossToNetActivePowerCurve : m_rid

      GrossToNetActivePowerCurve : names

          GrossToNetActivePowerCurve --> Name : names

      GrossToNetActivePowerCurve : properties_cimdata_object

          GrossToNetActivePowerCurve --> ChangeSetMember : properties_cimdata_object

      GrossToNetActivePowerCurve : targeting_cimdata_object

          GrossToNetActivePowerCurve --> ChangeSetMember : targeting_cimdata_object

      GrossToNetActivePowerCurve : x_multiplier

          GrossToNetActivePowerCurve --> UnitMultiplier : x_multiplier

      GrossToNetActivePowerCurve : x_unit

          GrossToNetActivePowerCurve --> UnitSymbol : x_unit

      GrossToNetActivePowerCurve : y_multiplier

          GrossToNetActivePowerCurve --> UnitMultiplier : y_multiplier

      GrossToNetActivePowerCurve : y_unit

          GrossToNetActivePowerCurve --> UnitSymbol : y_unit

Inheritance

Slots

Name Cardinality and Range Description Inheritance
generating_unit 1..1
GeneratingUnit
A generating unit may have a gross active power to net active power curve, de... direct
curve_style 0..1
CurveStyle
The style or shape of the curve Curve
x_multiplier 0..1
UnitMultiplier
Multiplier for X-axis Curve
x_unit 0..1
UnitSymbol
The X-axis units of measure Curve
y_multiplier 0..1
UnitMultiplier
Multiplier for Y3-axis Curve
y_unit 0..1
UnitSymbol
The Y3-axis units of measure Curve
curve_datas 0..*
CurveData
The point data values that define this curve Curve
alias_name 0..1
String
The aliasName is free text human readable name of the object alternative to I... IdentifiedObject
description 0..1
String
The description is a free human readable text describing or naming the object IdentifiedObject
m_rid 0..1
String
Master resource identifier issued by a model authority IdentifiedObject
diagram_objects 0..*
DiagramObject
The diagram objects that are associated with the domain object IdentifiedObject
instance_set 1..1
InstanceSet
Dataset containing the data objects IdentifiedObject
names 0..*
Name
All names of this identified object IdentifiedObject
properties_cimdata_object 0..1
ChangeSetMember
The single CIM data object in the appropriate dataset context IdentifiedObject
targeting_cimdata_object 0..*
ChangeSetMember
Data objects registered IdentifiedObject

Usages

used by used in type used
ThermalGeneratingUnit gross_to_net_active_power_curves range GrossToNetActivePowerCurve
GeneratingUnit gross_to_net_active_power_curves range GrossToNetActivePowerCurve
HydroGeneratingUnit gross_to_net_active_power_curves range GrossToNetActivePowerCurve
MktGeneratingUnit gross_to_net_active_power_curves range GrossToNetActivePowerCurve
MktThermalGeneratingUnit gross_to_net_active_power_curves range GrossToNetActivePowerCurve
NuclearGeneratingUnit gross_to_net_active_power_curves range GrossToNetActivePowerCurve
WindGeneratingUnit gross_to_net_active_power_curves range GrossToNetActivePowerCurve
SolarGeneratingUnit gross_to_net_active_power_curves range GrossToNetActivePowerCurve

Identifier and Mapping Information

Schema Source

  • from schema: https://cim.ucaiug.io/ns#TC57CIM

Mappings

Mapping Type Mapped Value
self cim:GrossToNetActivePowerCurve
native cim:GrossToNetActivePowerCurve

LinkML Source

Direct

name: GrossToNetActivePowerCurve
description: Relationship between the generating unit's gross active power output
  on the X-axis (measured at the terminals of the machine(s)) and the generating unit's
  net active power output on the Y-axis (based on utility-defined measurements at
  the power station). Station service loads, when modelled, should be treated as non-conforming
  bus loads. There may be more than one curve, depending on the auxiliary equipment
  that is in service.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
is_a: Curve
attributes:
  generating_unit:
    name: generating_unit
    description: A generating unit may have a gross active power to net active power
      curve, describing the losses and auxiliary power requirements of the unit.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:GrossToNetActivePowerCurve.GeneratingUnit
    multivalued: false
    domain_of:
    - UnitInitialConditions
    - GenUnitOpSchedule
    - ControlAreaGeneratingUnit
    - GrossToNetActivePowerCurve
    - GenUnitOpCostCurve
    - RotatingMachine
    range: GeneratingUnit
    required: true
class_uri: cim:GrossToNetActivePowerCurve

Induced

name: GrossToNetActivePowerCurve
description: Relationship between the generating unit's gross active power output
  on the X-axis (measured at the terminals of the machine(s)) and the generating unit's
  net active power output on the Y-axis (based on utility-defined measurements at
  the power station). Station service loads, when modelled, should be treated as non-conforming
  bus loads. There may be more than one curve, depending on the auxiliary equipment
  that is in service.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
is_a: Curve
attributes:
  generating_unit:
    name: generating_unit
    description: A generating unit may have a gross active power to net active power
      curve, describing the losses and auxiliary power requirements of the unit.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:GrossToNetActivePowerCurve.GeneratingUnit
    multivalued: false
    alias: generating_unit
    owner: GrossToNetActivePowerCurve
    domain_of:
    - UnitInitialConditions
    - GenUnitOpSchedule
    - ControlAreaGeneratingUnit
    - GrossToNetActivePowerCurve
    - GenUnitOpCostCurve
    - RotatingMachine
    range: GeneratingUnit
    required: true
  curve_style:
    name: curve_style
    description: The style or shape of the curve.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Curve.curveStyle
    multivalued: false
    alias: curve_style
    owner: GrossToNetActivePowerCurve
    domain_of:
    - Curve
    range: CurveStyle
    required: false
  x_multiplier:
    name: x_multiplier
    description: Multiplier for X-axis.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Curve.xMultiplier
    multivalued: false
    alias: x_multiplier
    owner: GrossToNetActivePowerCurve
    domain_of:
    - Curve
    range: UnitMultiplier
    required: false
  x_unit:
    name: x_unit
    description: The X-axis units of measure.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Curve.xUnit
    multivalued: false
    alias: x_unit
    owner: GrossToNetActivePowerCurve
    domain_of:
    - Curve
    range: UnitSymbol
    required: false
  y_multiplier:
    name: y_multiplier
    description: Multiplier for Y3-axis.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Curve.y3Multiplier
    multivalued: false
    alias: y_multiplier
    owner: GrossToNetActivePowerCurve
    domain_of:
    - Curve
    - DERMonitorableParameter
    range: UnitMultiplier
    required: false
  y_unit:
    name: y_unit
    description: The Y3-axis units of measure.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Curve.y3Unit
    multivalued: false
    alias: y_unit
    owner: GrossToNetActivePowerCurve
    domain_of:
    - Curve
    - DERMonitorableParameter
    range: UnitSymbol
    required: false
  curve_datas:
    name: curve_datas
    description: The point data values that define this curve.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Curve.CurveDatas
    multivalued: true
    alias: curve_datas
    owner: GrossToNetActivePowerCurve
    domain_of:
    - Curve
    range: CurveData
    required: false
  alias_name:
    name: alias_name
    description: "The aliasName is free text human readable name of the object alternative\
      \ to IdentifiedObject.name. It may be non unique and may not correlate to a\
      \ naming hierarchy.\r\nThe attribute aliasName is retained because of backwards\
      \ compatibility between CIM relases. It is however recommended to replace aliasName\
      \ with the Name class as aliasName is planned for retirement at a future time.\r\
      \n\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.aliasName
    multivalued: false
    alias: alias_name
    owner: GrossToNetActivePowerCurve
    domain_of:
    - IdentifiedObject
    range: string
    required: false
  description:
    name: description
    description: The description is a free human readable text describing or naming
      the object. It may be non unique and may not correlate to a naming hierarchy.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.description
    multivalued: false
    alias: description
    owner: GrossToNetActivePowerCurve
    domain_of:
    - IdentifiedObject
    - NameType
    - NameTypeAuthority
    - DataSet
    - SwitchingStepGroup
    - AreaReserveSpec
    range: string
    required: false
  m_rid:
    name: m_rid
    description: "Master resource identifier issued by a model authority. The mRID\
      \ is unique within an exchange context. Global uniqueness is easily achieved\
      \ by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is\
      \ strongly recommended.\r\nFor CIMXML data files in RDF syntax conforming to\
      \ IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify\
      \ CIM object elements."
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.mRID
    multivalued: false
    alias: m_rid
    owner: GrossToNetActivePowerCurve
    domain_of:
    - IdentifiedObject
    - DataSet
    range: string
    required: false
  diagram_objects:
    name: diagram_objects
    description: The diagram objects that are associated with the domain object.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.DiagramObjects
    multivalued: true
    alias: diagram_objects
    owner: GrossToNetActivePowerCurve
    domain_of:
    - IdentifiedObject
    range: DiagramObject
    required: false
  instance_set:
    name: instance_set
    description: Dataset containing the data objects.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.InstanceSet
    multivalued: false
    alias: instance_set
    owner: GrossToNetActivePowerCurve
    domain_of:
    - IdentifiedObject
    range: InstanceSet
    required: true
  names:
    name: names
    description: All names of this identified object.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.Names
    multivalued: true
    alias: names
    owner: GrossToNetActivePowerCurve
    domain_of:
    - IdentifiedObject
    - NameType
    range: Name
    required: false
  properties_cimdata_object:
    name: properties_cimdata_object
    description: The single CIM data object in the appropriate dataset context.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.PropertiesCIMDataObject
    multivalued: false
    alias: properties_cimdata_object
    owner: GrossToNetActivePowerCurve
    domain_of:
    - IdentifiedObject
    range: ChangeSetMember
    required: false
  targeting_cimdata_object:
    name: targeting_cimdata_object
    description: Data objects registered.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.TargetingCIMDataObject
    multivalued: true
    alias: targeting_cimdata_object
    owner: GrossToNetActivePowerCurve
    domain_of:
    - IdentifiedObject
    range: ChangeSetMember
    required: false
class_uri: cim:GrossToNetActivePowerCurve