Skip to content

Class: GovSteamFV4

Detailed electro-hydraulic governor for steam unit.

URI: cim:GovSteamFV4

 classDiagram
    class GovSteamFV4
      TurbineGovernorDynamics <|-- GovSteamFV4

      GovSteamFV4 : alias_name

      GovSteamFV4 : asynchronous_machine_dynamics

          GovSteamFV4 --> AsynchronousMachineDynamics : asynchronous_machine_dynamics

      GovSteamFV4 : cpsmn

          GovSteamFV4 --> PU : cpsmn

      GovSteamFV4 : cpsmx

          GovSteamFV4 --> PU : cpsmx

      GovSteamFV4 : crmn

          GovSteamFV4 --> PU : crmn

      GovSteamFV4 : crmx

          GovSteamFV4 --> PU : crmx

      GovSteamFV4 : description

      GovSteamFV4 : diagram_objects

          GovSteamFV4 --> DiagramObject : diagram_objects

      GovSteamFV4 : enabled

      GovSteamFV4 : instance_set

          GovSteamFV4 --> InstanceSet : instance_set

      GovSteamFV4 : kdc

          GovSteamFV4 --> PU : kdc

      GovSteamFV4 : kf

          GovSteamFV4 --> PU : kf

      GovSteamFV4 : khp

          GovSteamFV4 --> PU : khp

      GovSteamFV4 : kic

          GovSteamFV4 --> PU : kic

      GovSteamFV4 : kip

          GovSteamFV4 --> PU : kip

      GovSteamFV4 : kit

          GovSteamFV4 --> PU : kit

      GovSteamFV4 : kmp

          GovSteamFV4 --> PU : kmp

      GovSteamFV4 : kpc

          GovSteamFV4 --> PU : kpc

      GovSteamFV4 : kpp

          GovSteamFV4 --> PU : kpp

      GovSteamFV4 : kpt

          GovSteamFV4 --> PU : kpt

      GovSteamFV4 : krc

          GovSteamFV4 --> PU : krc

      GovSteamFV4 : ksh

          GovSteamFV4 --> PU : ksh

      GovSteamFV4 : lpi

          GovSteamFV4 --> PU : lpi

      GovSteamFV4 : lps

          GovSteamFV4 --> PU : lps

      GovSteamFV4 : m_rid

      GovSteamFV4 : mnef

          GovSteamFV4 --> PU : mnef

      GovSteamFV4 : mxef

          GovSteamFV4 --> PU : mxef

      GovSteamFV4 : names

          GovSteamFV4 --> Name : names

      GovSteamFV4 : pr

          GovSteamFV4 --> PU : pr

      GovSteamFV4 : properties_cimdata_object

          GovSteamFV4 --> ChangeSetMember : properties_cimdata_object

      GovSteamFV4 : psmn

          GovSteamFV4 --> PU : psmn

      GovSteamFV4 : rsmimn

          GovSteamFV4 --> PU : rsmimn

      GovSteamFV4 : rsmimx

          GovSteamFV4 --> PU : rsmimx

      GovSteamFV4 : rvgmn

          GovSteamFV4 --> PU : rvgmn

      GovSteamFV4 : rvgmx

          GovSteamFV4 --> PU : rvgmx

      GovSteamFV4 : srmn

          GovSteamFV4 --> PU : srmn

      GovSteamFV4 : srmx

          GovSteamFV4 --> PU : srmx

      GovSteamFV4 : srsmp

          GovSteamFV4 --> PU : srsmp

      GovSteamFV4 : svmn

      GovSteamFV4 : svmx

      GovSteamFV4 : synchronous_machine_dynamics

          GovSteamFV4 --> SynchronousMachineDynamics : synchronous_machine_dynamics

      GovSteamFV4 : ta

          GovSteamFV4 --> Seconds : ta

      GovSteamFV4 : tam

          GovSteamFV4 --> Seconds : tam

      GovSteamFV4 : targeting_cimdata_object

          GovSteamFV4 --> ChangeSetMember : targeting_cimdata_object

      GovSteamFV4 : tc

          GovSteamFV4 --> Seconds : tc

      GovSteamFV4 : tcm

          GovSteamFV4 --> Seconds : tcm

      GovSteamFV4 : tdc

          GovSteamFV4 --> Seconds : tdc

      GovSteamFV4 : tf

          GovSteamFV4 --> Seconds : tf

      GovSteamFV4 : thp

          GovSteamFV4 --> Seconds : thp

      GovSteamFV4 : tmp

          GovSteamFV4 --> Seconds : tmp

      GovSteamFV4 : trh

          GovSteamFV4 --> Seconds : trh

      GovSteamFV4 : turbine_load_controller_dynamics

          GovSteamFV4 --> TurbineLoadControllerDynamics : turbine_load_controller_dynamics

      GovSteamFV4 : tv

          GovSteamFV4 --> Seconds : tv

      GovSteamFV4 : ty

          GovSteamFV4 --> Seconds : ty

      GovSteamFV4 : y

          GovSteamFV4 --> PU : y

      GovSteamFV4 : yhpmn

          GovSteamFV4 --> PU : yhpmn

      GovSteamFV4 : yhpmx

          GovSteamFV4 --> PU : yhpmx

      GovSteamFV4 : ympmn

          GovSteamFV4 --> PU : ympmn

      GovSteamFV4 : ympmx

          GovSteamFV4 --> PU : ympmx

Inheritance

Slots

Name Cardinality and Range Description Inheritance
cpsmn 0..1
PU
Minimum value of pressure regulator output (Cpsmn) direct
cpsmx 0..1
PU
Maximum value of pressure regulator output (Cpsmx) direct
crmn 0..1
PU
Minimum value of regulator set-point (Crmn) direct
crmx 0..1
PU
Maximum value of regulator set-point (Crmx) direct
kdc 0..1
PU
Derivative gain of pressure regulator (Kdc) direct
kf 0..1
PU
Frequency control (reciprocal of droop) (Kf3) direct
khp 0..1
PU
Fraction of total turbine output generated by HP part (Khp) direct
kic 0..1
PU
Integral gain of pressure regulator (Kic) direct
kip 0..1
PU
Integral gain of pressure feedback regulator (Kip) direct
kit 0..1
PU
Integral gain of electro-hydraulic regulator (Kit) direct
kmp 0..1
PU
Second gain coefficient of intercept valves characteristic (Kmp2) direct
kpc 0..1
PU
Proportional gain of pressure regulator (Kpc) direct
kpp 0..1
PU
Proportional gain of pressure feedback regulator (Kpp) direct
kpt 0..1
PU
Proportional gain of electro-hydraulic regulator (Kpt) direct
krc 0..1
PU
Maximum variation of fuel flow (Krc) direct
ksh 0..1
PU
Pressure loss due to flow friction in the boiler tubes (Ksh) direct
lpi 0..1
PU
Maximum negative power error (Lpi) direct
lps 0..1
PU
Maximum positive power error (Lps) direct
mnef 0..1
PU
Lower limit for frequency correction (MNEF) direct
mxef 0..1
PU
Upper limit for frequency correction (MXEF) direct
pr 0..1
PU
Second value of pressure set point static characteristic, corresponding to <i... direct
psmn 0..1
PU
Minimum value of pressure set point static characteristic (Psmn) direct
rsmimn 0..1
PU
Minimum value of integral regulator (Rsmimn) direct
rsmimx 0..1
PU
Maximum value of integral regulator (Rsmimx) direct
rvgmn 0..1
PU
Minimum value of integral regulator (Rvgmn) direct
rvgmx 0..1
PU
Maximum value of integral regulator (Rvgmx) direct
srmn 0..1
PU
Minimum valve opening (Srmn) direct
srmx 0..1
PU
Maximum valve opening (Srmx) direct
srsmp 0..1
PU
Intercept valves characteristic discontinuity point (Srsmp) direct
svmn 0..1
Float
Maximum regulator gate closing velocity (Svmn) direct
svmx 0..1
Float
Maximum regulator gate opening velocity (Svmx) direct
ta 0..1
Seconds
Control valves rate opening time (Ta) (>= 0) direct
tam 0..1
Seconds
Intercept valves rate opening time (Tam) (>= 0) direct
tc 0..1
Seconds
Control valves rate closing time (Tc) (>= 0) direct
tcm 0..1
Seconds
Intercept valves rate closing time (Tcm) (>= 0) direct
tdc 0..1
Seconds
Derivative time constant of pressure regulator (Tdc) (>= 0) direct
tf 0..1
Seconds
Time constant of steam chest (Tf2) (>= 0) direct
thp 0..1
Seconds
High pressure (HP) time constant of the turbine (Thp) (>= 0) direct
tmp 0..1
Seconds
Low pressure (LP) time constant of the turbine (Tmp) (>= 0) direct
trh 0..1
Seconds
Reheater time constant of the turbine (Trh) (>= 0) direct
tv 0..1
Seconds
Boiler time constant (Tv) (>= 0) direct
ty 0..1
Seconds
Control valves servo time constant (Ty) (>= 0) direct
y 0..1
PU
Coefficient of linearized equations of turbine (Stodola formulation) (Y</i... direct
yhpmn 0..1
PU
Minimum control valve position (Yhpmn) direct
yhpmx 0..1
PU
Maximum control valve position (Yhpmx) direct
ympmn 0..1
PU
Minimum intercept valve position (Ympmn) direct
ympmx 0..1
PU
Maximum intercept valve position (Ympmx) direct
asynchronous_machine_dynamics 0..1
AsynchronousMachineDynamics
Asynchronous machine model with which this turbine-governor model is associat... TurbineGovernorDynamics
turbine_load_controller_dynamics 0..1
TurbineLoadControllerDynamics
Turbine load controller providing input to this turbine-governor TurbineGovernorDynamics
synchronous_machine_dynamics 0..1
SynchronousMachineDynamics
Synchronous machine model with which this turbine-governor model is associate... TurbineGovernorDynamics
enabled 0..1
Boolean
Function block used indicator DynamicsFunctionBlock
alias_name 0..1
String
The aliasName is free text human readable name of the object alternative to I... IdentifiedObject
description 0..1
String
The description is a free human readable text describing or naming the object IdentifiedObject
m_rid 0..1
String
Master resource identifier issued by a model authority IdentifiedObject
diagram_objects 0..*
DiagramObject
The diagram objects that are associated with the domain object IdentifiedObject
instance_set 1..1
InstanceSet
Dataset containing the data objects IdentifiedObject
names 0..*
Name
All names of this identified object IdentifiedObject
properties_cimdata_object 0..1
ChangeSetMember
The single CIM data object in the appropriate dataset context IdentifiedObject
targeting_cimdata_object 0..*
ChangeSetMember
Data objects registered IdentifiedObject

Identifier and Mapping Information

Schema Source

  • from schema: https://cim.ucaiug.io/ns#TC57CIM

Mappings

Mapping Type Mapped Value
self cim:GovSteamFV4
native cim:GovSteamFV4

LinkML Source

Direct

name: GovSteamFV4
description: Detailed electro-hydraulic governor for steam unit.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
is_a: TurbineGovernorDynamics
attributes:
  cpsmn:
    name: cpsmn
    description: Minimum value of pressure regulator output (<i>Cpsmn</i>).  Typical
      value = -1.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.cpsmn
    multivalued: false
    domain_of:
    - GovSteamFV4
    range: PU
    required: false
  cpsmx:
    name: cpsmx
    description: Maximum value of pressure regulator output (<i>Cpsmx</i>).  Typical
      value = 1.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.cpsmx
    multivalued: false
    domain_of:
    - GovSteamFV4
    range: PU
    required: false
  crmn:
    name: crmn
    description: Minimum value of regulator set-point (<i>Crmn</i>).  Typical value
      = 0.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.crmn
    multivalued: false
    domain_of:
    - GovSteamFV4
    range: PU
    required: false
  crmx:
    name: crmx
    description: Maximum value of regulator set-point (<i>Crmx</i>).  Typical value
      = 1,2.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.crmx
    multivalued: false
    domain_of:
    - GovSteamFV4
    range: PU
    required: false
  kdc:
    name: kdc
    description: Derivative gain of pressure regulator (<i>Kdc</i>).  Typical value
      = 1.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.kdc
    multivalued: false
    domain_of:
    - GovSteamFV4
    range: PU
    required: false
  kf:
    name: kf
    description: Frequency control (reciprocal of droop) (<i>Kf3</i>).  Typical value
      = 20.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:GovSteamFV4.kf3
    multivalued: false
    domain_of:
    - GovGAST2
    - GovGASTWD
    - GovSteamFV4
    - ExcIEEEAC1A
    - ExcIEEEAC2A
    - ExcIEEEAC3A
    - ExcIEEEAC5A
    - ExcIEEEAC7B
    - ExcIEEEDC1A
    - ExcIEEEDC2A
    - ExcIEEEDC4B
    - ExcIEEEST1A
    - ExcIEEEST2A
    - ExcAC1A
    - ExcAC2A
    - ExcAC3A
    - ExcAC5A
    - ExcAVR1
    - ExcAVR2
    - ExcDC1A
    - ExcDC2A
    - ExcDC3A1
    - ExcNI
    - ExcOEX3T
    - ExcPIC
    - ExcREXS
    - ExcST1A
    - ExcST2A
    - UnderexcLimX1
    - UnderexcLimX2
    - Pss1
    - Pss5
    range: PU
    required: false
  khp:
    name: khp
    description: Fraction  of total turbine output generated by HP part (<i>Khp</i>).  Typical
      value = 0,35.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:GovSteamFV4.khp
    multivalued: false
    domain_of:
    - GovSteamEU
    - GovSteamFV4
    range: PU
    required: false
  kic:
    name: kic
    description: Integral gain of pressure regulator (<i>Kic</i>).  Typical value
      = 0,0033.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.kic
    multivalued: false
    domain_of:
    - GovSteamFV4
    - WindContPitchAngleIEC
    range: PU
    required: false
  kip:
    name: kip
    description: Integral gain of pressure feedback regulator (<i>Kip</i>).  Typical
      value = 0,5.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.kip
    multivalued: false
    domain_of:
    - GovSteamFV4
    - ExcREXS
    - WindContPType3IEC
    range: PU
    required: false
  kit:
    name: kit
    description: Integral gain of electro-hydraulic regulator (<i>Kit</i>).  Typical
      value = 0,04.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.kit
    multivalued: false
    domain_of:
    - GovSteamFV4
    range: PU
    required: false
  kmp:
    name: kmp
    description: Second gain coefficient of intercept valves characteristic (<i>Kmp2</i>).  Typical
      value = 3,5.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.kmp2
    multivalued: false
    domain_of:
    - GovSteamFV4
    range: PU
    required: false
  kpc:
    name: kpc
    description: Proportional gain of pressure regulator (<i>Kpc</i>).  Typical value
      = 0,5.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.kpc
    multivalued: false
    domain_of:
    - GovSteamFV4
    - WindGenType3aIEC
    - WindContPitchAngleIEC
    range: PU
    required: false
  kpp:
    name: kpp
    description: Proportional gain of pressure feedback regulator (<i>Kpp</i>).  Typical
      value = 1.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.kpp
    multivalued: false
    domain_of:
    - GovSteamFV4
    - WindContPType3IEC
    range: PU
    required: false
  kpt:
    name: kpt
    description: Proportional gain of electro-hydraulic regulator (<i>Kpt</i>).  Typical
      value = 0,3.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.kpt
    multivalued: false
    domain_of:
    - GovSteamFV4
    range: PU
    required: false
  krc:
    name: krc
    description: Maximum variation of fuel flow (<i>Krc</i>).  Typical value = 0,05.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.krc
    multivalued: false
    domain_of:
    - GovSteamFV4
    range: PU
    required: false
  ksh:
    name: ksh
    description: Pressure loss due to flow friction in the boiler tubes (<i>Ksh</i>).  Typical
      value = 0,08.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.ksh
    multivalued: false
    domain_of:
    - GovSteamFV4
    range: PU
    required: false
  lpi:
    name: lpi
    description: Maximum negative power error (<i>Lpi</i>).  Typical value = -0,15.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.lpi
    multivalued: false
    domain_of:
    - GovSteamFV4
    range: PU
    required: false
  lps:
    name: lps
    description: Maximum positive power error (<i>Lps</i>).  Typical value = 0,03.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.lps
    multivalued: false
    domain_of:
    - GovSteamFV4
    range: PU
    required: false
  mnef:
    name: mnef
    description: Lower limit for frequency correction (<i>MN</i><i><sub>EF</sub></i>).  Typical
      value = -0,05.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:GovSteamFV4.mnef
    multivalued: false
    domain_of:
    - GovGAST3
    - GovGAST4
    - GovSteam2
    - GovSteamFV4
    range: PU
    required: false
  mxef:
    name: mxef
    description: Upper limit for frequency correction (<i>MX</i><i><sub>EF</sub></i>).  Typical
      value = 0,05.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:GovSteamFV4.mxef
    multivalued: false
    domain_of:
    - GovGAST3
    - GovGAST4
    - GovSteam2
    - GovSteamFV4
    range: PU
    required: false
  pr:
    name: pr
    description: Second value of pressure set point static characteristic, corresponding
      to <i>Ps0</i> = 1,0 PU (<i>Pr2</i>).  Typical value = 0,75.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.pr2
    multivalued: false
    domain_of:
    - GovSteamFV4
    range: PU
    required: false
  psmn:
    name: psmn
    description: Minimum value of pressure set point static characteristic (<i>Psmn</i>).  Typical
      value = 1.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.psmn
    multivalued: false
    domain_of:
    - GovSteamFV4
    range: PU
    required: false
  rsmimn:
    name: rsmimn
    description: Minimum value of integral regulator (<i>Rsmimn</i>).  Typical value
      = 0.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.rsmimn
    multivalued: false
    domain_of:
    - GovSteamFV4
    range: PU
    required: false
  rsmimx:
    name: rsmimx
    description: Maximum value of integral regulator (<i>Rsmimx</i>).  Typical value
      = 1,1.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.rsmimx
    multivalued: false
    domain_of:
    - GovSteamFV4
    range: PU
    required: false
  rvgmn:
    name: rvgmn
    description: Minimum value of integral regulator (<i>Rvgmn</i>).  Typical value
      = 0.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.rvgmn
    multivalued: false
    domain_of:
    - GovSteamFV4
    range: PU
    required: false
  rvgmx:
    name: rvgmx
    description: Maximum value of integral regulator (<i>Rvgmx</i>).  Typical value
      = 1,2.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.rvgmx
    multivalued: false
    domain_of:
    - GovSteamFV4
    range: PU
    required: false
  srmn:
    name: srmn
    description: Minimum valve opening (<i>Srmn</i>).  Typical value = 0.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.srmn
    multivalued: false
    domain_of:
    - GovSteamFV4
    range: PU
    required: false
  srmx:
    name: srmx
    description: Maximum valve opening (<i>Srmx</i>).  Typical value = 1,1.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.srmx
    multivalued: false
    domain_of:
    - GovSteamFV4
    range: PU
    required: false
  srsmp:
    name: srsmp
    description: Intercept valves characteristic discontinuity point (<i>Srsmp</i>).  Typical
      value = 0,43.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.srsmp
    multivalued: false
    domain_of:
    - GovSteamFV4
    range: PU
    required: false
  svmn:
    name: svmn
    description: Maximum regulator gate closing velocity (<i>Svmn</i>).  Typical value
      = -0,0333.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.svmn
    multivalued: false
    domain_of:
    - GovSteamFV4
    range: float
    required: false
  svmx:
    name: svmx
    description: Maximum regulator gate opening velocity (<i>Svmx</i>).  Typical value
      = 0,0333.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.svmx
    multivalued: false
    domain_of:
    - GovSteamFV4
    range: float
    required: false
  ta:
    name: ta
    description: Control valves rate opening time (<i>Ta</i>) (&gt;= 0).  Typical
      value = 0,8.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:GovSteamFV4.ta
    multivalued: false
    domain_of:
    - GovCT1
    - GovCT2
    - GovGAST4
    - GovHydroFrancis
    - GovHydroPelton
    - GovHydroPID2
    - GovHydroWPID
    - GovSteamFV2
    - GovSteamFV3
    - GovSteamFV4
    - ExcIEEEAC1A
    - ExcIEEEAC2A
    - ExcIEEEAC3A
    - ExcIEEEAC4A
    - ExcIEEEAC5A
    - ExcIEEEAC6A
    - ExcIEEEAC8B
    - ExcIEEEDC1A
    - ExcIEEEDC2A
    - ExcIEEEDC4B
    - ExcIEEEST1A
    - ExcIEEEST2A
    - ExcIEEEST3A
    - ExcIEEEST4B
    - ExcAC1A
    - ExcAC2A
    - ExcAC3A
    - ExcAC4A
    - ExcAC5A
    - ExcAC6A
    - ExcAC8B
    - ExcAVR1
    - ExcAVR2
    - ExcAVR5
    - ExcCZ
    - ExcDC1A
    - ExcDC2A
    - ExcDC3A1
    - ExcNI
    - ExcPIC
    - ExcREXS
    - ExcST1A
    - ExcST2A
    - ExcST4B
    - Pss2B
    - PssSB4
    range: Seconds
    required: false
  tam:
    name: tam
    description: Intercept valves rate opening time (<i>Tam</i>) (&gt;= 0).  Typical
      value = 0,8.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.tam
    multivalued: false
    domain_of:
    - GovSteamFV4
    range: Seconds
    required: false
  tc:
    name: tc
    description: Control valves rate closing time (<i>Tc</i>) (&gt;= 0).  Typical
      value = 0,5.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:GovSteamFV4.tc
    multivalued: false
    domain_of:
    - SynchronousMachineTimeConstantReactance
    - GovCT1
    - GovCT2
    - GovGAST2
    - GovGAST3
    - GovGAST4
    - GovGASTWD
    - GovSteamFV2
    - GovSteamFV3
    - GovSteamFV4
    - ExcIEEEAC1A
    - ExcIEEEAC2A
    - ExcIEEEAC3A
    - ExcIEEEAC4A
    - ExcIEEEAC6A
    - ExcIEEEDC1A
    - ExcIEEEDC2A
    - ExcIEEEST1A
    - ExcIEEEST3A
    - ExcIEEEST5B
    - ExcIEEEST7B
    - ExcAC1A
    - ExcAC2A
    - ExcAC3A
    - ExcAC4A
    - ExcAC5A
    - ExcAC6A
    - ExcCZ
    - ExcDC1A
    - ExcDC2A
    - ExcREXS
    - ExcRQB
    - ExcSEXS
    - ExcSK
    - ExcST1A
    - ExcST2A
    - ExcST3A
    - ExcST7B
    - PssSB4
    range: Seconds
    required: false
  tcm:
    name: tcm
    description: Intercept valves rate closing time (<i>Tcm</i>) (&gt;= 0).  Typical
      value = 0,5.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:GovSteamFV4.tcm
    multivalued: false
    domain_of:
    - GovGAST4
    - GovSteamFV4
    range: Seconds
    required: false
  tdc:
    name: tdc
    description: Derivative time constant of pressure regulator (<i>Tdc</i>) (&gt;=
      0).  Typical value = 90.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.tdc
    multivalued: false
    domain_of:
    - GovSteamFV4
    range: Seconds
    required: false
  tf:
    name: tf
    description: Time constant of steam chest (<i>Tf2</i>) (&gt;= 0).  Typical value
      = 10.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:GovSteamFV4.tf2
    multivalued: false
    domain_of:
    - GovGAST2
    - GovGASTWD
    - GovHydro1
    - GovHydro3
    - GovHydroDD
    - GovHydroPID
    - GovSteamEU
    - GovSteamFV4
    - ExcIEEEAC1A
    - ExcIEEEAC2A
    - ExcIEEEAC3A
    - ExcIEEEAC5A
    - ExcIEEEAC7B
    - ExcIEEEDC1A
    - ExcIEEEDC2A
    - ExcIEEEDC4B
    - ExcIEEEST1A
    - ExcIEEEST2A
    - ExcIEEEST7B
    - ExcAC1A
    - ExcAC2A
    - ExcAC3A
    - ExcAC5A
    - ExcAVR1
    - ExcAVR2
    - ExcDC1A
    - ExcDC2A
    - ExcDC3A1
    - ExcNI
    - ExcOEX3T
    - ExcPIC
    - ExcREXS
    - ExcRQB
    - ExcST1A
    - ExcST2A
    - ExcST7B
    - UnderexcLimX1
    - UnderexcLimX2
    - PssPTIST1
    - PssPTIST3
    range: Seconds
    required: false
  thp:
    name: thp
    description: High pressure (HP) time constant of the turbine (<i>Thp</i>) (&gt;=
      0).  Typical value = 0,15.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:GovSteamFV4.thp
    multivalued: false
    domain_of:
    - GovSteamEU
    - GovSteamFV4
    range: Seconds
    required: false
  tmp:
    name: tmp
    description: Low pressure (LP) time constant of the turbine (<i>Tmp</i>) (&gt;=
      0).  Typical value = 0,4.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.tmp
    multivalued: false
    domain_of:
    - GovSteamFV4
    range: Seconds
    required: false
  trh:
    name: trh
    description: Reheater  time constant of the turbine (<i>Trh</i>) (&gt;= 0).  Typical
      value = 10.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:GovSteamFV4.trh
    multivalued: false
    domain_of:
    - GovSteamEU
    - GovSteamFV4
    - ExcIEEEDC3A
    - ExcDC3A
    range: Seconds
    required: false
  tv:
    name: tv
    description: Boiler time constant (<i>Tv</i>) (&gt;= 0).  Typical value = 60.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:GovSteamFV4.tv
    multivalued: false
    domain_of:
    - GovHydroPelton
    - GovSteamFV4
    - LoadMotor
    range: Seconds
    required: false
  ty:
    name: ty
    description: Control valves servo time constant (<i>Ty</i>) (&gt;= 0).  Typical
      value = 0,1.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:GovSteamFV4.ty
    multivalued: false
    domain_of:
    - GovGAST3
    - GovGAST4
    - GovSteamFV4
    range: Seconds
    required: false
  y:
    name: y
    description: Coefficient of linearized equations of turbine (Stodola formulation)
      (<i>Y</i>).  Typical value = 0,13.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:GovSteamFV4.y
    multivalued: false
    domain_of:
    - GovGAST2
    - GovSteamFV4
    range: PU
    required: false
  yhpmn:
    name: yhpmn
    description: Minimum control valve position (<i>Yhpmn</i>).  Typical value = 0.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.yhpmn
    multivalued: false
    domain_of:
    - GovSteamFV4
    range: PU
    required: false
  yhpmx:
    name: yhpmx
    description: Maximum control valve position (<i>Yhpmx</i>).  Typical value = 1,1.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.yhpmx
    multivalued: false
    domain_of:
    - GovSteamFV4
    range: PU
    required: false
  ympmn:
    name: ympmn
    description: Minimum intercept valve position (<i>Ympmn</i>).  Typical value =
      0.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.ympmn
    multivalued: false
    domain_of:
    - GovSteamFV4
    range: PU
    required: false
  ympmx:
    name: ympmx
    description: Maximum intercept valve position (<i>Ympmx</i>).  Typical value =
      1,1.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.ympmx
    multivalued: false
    domain_of:
    - GovSteamFV4
    range: PU
    required: false
class_uri: cim:GovSteamFV4

Induced

name: GovSteamFV4
description: Detailed electro-hydraulic governor for steam unit.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
is_a: TurbineGovernorDynamics
attributes:
  cpsmn:
    name: cpsmn
    description: Minimum value of pressure regulator output (<i>Cpsmn</i>).  Typical
      value = -1.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.cpsmn
    multivalued: false
    alias: cpsmn
    owner: GovSteamFV4
    domain_of:
    - GovSteamFV4
    range: PU
    required: false
  cpsmx:
    name: cpsmx
    description: Maximum value of pressure regulator output (<i>Cpsmx</i>).  Typical
      value = 1.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.cpsmx
    multivalued: false
    alias: cpsmx
    owner: GovSteamFV4
    domain_of:
    - GovSteamFV4
    range: PU
    required: false
  crmn:
    name: crmn
    description: Minimum value of regulator set-point (<i>Crmn</i>).  Typical value
      = 0.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.crmn
    multivalued: false
    alias: crmn
    owner: GovSteamFV4
    domain_of:
    - GovSteamFV4
    range: PU
    required: false
  crmx:
    name: crmx
    description: Maximum value of regulator set-point (<i>Crmx</i>).  Typical value
      = 1,2.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.crmx
    multivalued: false
    alias: crmx
    owner: GovSteamFV4
    domain_of:
    - GovSteamFV4
    range: PU
    required: false
  kdc:
    name: kdc
    description: Derivative gain of pressure regulator (<i>Kdc</i>).  Typical value
      = 1.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.kdc
    multivalued: false
    alias: kdc
    owner: GovSteamFV4
    domain_of:
    - GovSteamFV4
    range: PU
    required: false
  kf:
    name: kf
    description: Frequency control (reciprocal of droop) (<i>Kf3</i>).  Typical value
      = 20.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:GovSteamFV4.kf3
    multivalued: false
    alias: kf
    owner: GovSteamFV4
    domain_of:
    - GovGAST2
    - GovGASTWD
    - GovSteamFV4
    - ExcIEEEAC1A
    - ExcIEEEAC2A
    - ExcIEEEAC3A
    - ExcIEEEAC5A
    - ExcIEEEAC7B
    - ExcIEEEDC1A
    - ExcIEEEDC2A
    - ExcIEEEDC4B
    - ExcIEEEST1A
    - ExcIEEEST2A
    - ExcAC1A
    - ExcAC2A
    - ExcAC3A
    - ExcAC5A
    - ExcAVR1
    - ExcAVR2
    - ExcDC1A
    - ExcDC2A
    - ExcDC3A1
    - ExcNI
    - ExcOEX3T
    - ExcPIC
    - ExcREXS
    - ExcST1A
    - ExcST2A
    - UnderexcLimX1
    - UnderexcLimX2
    - Pss1
    - Pss5
    range: PU
    required: false
  khp:
    name: khp
    description: Fraction  of total turbine output generated by HP part (<i>Khp</i>).  Typical
      value = 0,35.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:GovSteamFV4.khp
    multivalued: false
    alias: khp
    owner: GovSteamFV4
    domain_of:
    - GovSteamEU
    - GovSteamFV4
    range: PU
    required: false
  kic:
    name: kic
    description: Integral gain of pressure regulator (<i>Kic</i>).  Typical value
      = 0,0033.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.kic
    multivalued: false
    alias: kic
    owner: GovSteamFV4
    domain_of:
    - GovSteamFV4
    - WindContPitchAngleIEC
    range: PU
    required: false
  kip:
    name: kip
    description: Integral gain of pressure feedback regulator (<i>Kip</i>).  Typical
      value = 0,5.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.kip
    multivalued: false
    alias: kip
    owner: GovSteamFV4
    domain_of:
    - GovSteamFV4
    - ExcREXS
    - WindContPType3IEC
    range: PU
    required: false
  kit:
    name: kit
    description: Integral gain of electro-hydraulic regulator (<i>Kit</i>).  Typical
      value = 0,04.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.kit
    multivalued: false
    alias: kit
    owner: GovSteamFV4
    domain_of:
    - GovSteamFV4
    range: PU
    required: false
  kmp:
    name: kmp
    description: Second gain coefficient of intercept valves characteristic (<i>Kmp2</i>).  Typical
      value = 3,5.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.kmp2
    multivalued: false
    alias: kmp
    owner: GovSteamFV4
    domain_of:
    - GovSteamFV4
    range: PU
    required: false
  kpc:
    name: kpc
    description: Proportional gain of pressure regulator (<i>Kpc</i>).  Typical value
      = 0,5.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.kpc
    multivalued: false
    alias: kpc
    owner: GovSteamFV4
    domain_of:
    - GovSteamFV4
    - WindGenType3aIEC
    - WindContPitchAngleIEC
    range: PU
    required: false
  kpp:
    name: kpp
    description: Proportional gain of pressure feedback regulator (<i>Kpp</i>).  Typical
      value = 1.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.kpp
    multivalued: false
    alias: kpp
    owner: GovSteamFV4
    domain_of:
    - GovSteamFV4
    - WindContPType3IEC
    range: PU
    required: false
  kpt:
    name: kpt
    description: Proportional gain of electro-hydraulic regulator (<i>Kpt</i>).  Typical
      value = 0,3.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.kpt
    multivalued: false
    alias: kpt
    owner: GovSteamFV4
    domain_of:
    - GovSteamFV4
    range: PU
    required: false
  krc:
    name: krc
    description: Maximum variation of fuel flow (<i>Krc</i>).  Typical value = 0,05.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.krc
    multivalued: false
    alias: krc
    owner: GovSteamFV4
    domain_of:
    - GovSteamFV4
    range: PU
    required: false
  ksh:
    name: ksh
    description: Pressure loss due to flow friction in the boiler tubes (<i>Ksh</i>).  Typical
      value = 0,08.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.ksh
    multivalued: false
    alias: ksh
    owner: GovSteamFV4
    domain_of:
    - GovSteamFV4
    range: PU
    required: false
  lpi:
    name: lpi
    description: Maximum negative power error (<i>Lpi</i>).  Typical value = -0,15.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.lpi
    multivalued: false
    alias: lpi
    owner: GovSteamFV4
    domain_of:
    - GovSteamFV4
    range: PU
    required: false
  lps:
    name: lps
    description: Maximum positive power error (<i>Lps</i>).  Typical value = 0,03.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.lps
    multivalued: false
    alias: lps
    owner: GovSteamFV4
    domain_of:
    - GovSteamFV4
    range: PU
    required: false
  mnef:
    name: mnef
    description: Lower limit for frequency correction (<i>MN</i><i><sub>EF</sub></i>).  Typical
      value = -0,05.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:GovSteamFV4.mnef
    multivalued: false
    alias: mnef
    owner: GovSteamFV4
    domain_of:
    - GovGAST3
    - GovGAST4
    - GovSteam2
    - GovSteamFV4
    range: PU
    required: false
  mxef:
    name: mxef
    description: Upper limit for frequency correction (<i>MX</i><i><sub>EF</sub></i>).  Typical
      value = 0,05.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:GovSteamFV4.mxef
    multivalued: false
    alias: mxef
    owner: GovSteamFV4
    domain_of:
    - GovGAST3
    - GovGAST4
    - GovSteam2
    - GovSteamFV4
    range: PU
    required: false
  pr:
    name: pr
    description: Second value of pressure set point static characteristic, corresponding
      to <i>Ps0</i> = 1,0 PU (<i>Pr2</i>).  Typical value = 0,75.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.pr2
    multivalued: false
    alias: pr
    owner: GovSteamFV4
    domain_of:
    - GovSteamFV4
    range: PU
    required: false
  psmn:
    name: psmn
    description: Minimum value of pressure set point static characteristic (<i>Psmn</i>).  Typical
      value = 1.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.psmn
    multivalued: false
    alias: psmn
    owner: GovSteamFV4
    domain_of:
    - GovSteamFV4
    range: PU
    required: false
  rsmimn:
    name: rsmimn
    description: Minimum value of integral regulator (<i>Rsmimn</i>).  Typical value
      = 0.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.rsmimn
    multivalued: false
    alias: rsmimn
    owner: GovSteamFV4
    domain_of:
    - GovSteamFV4
    range: PU
    required: false
  rsmimx:
    name: rsmimx
    description: Maximum value of integral regulator (<i>Rsmimx</i>).  Typical value
      = 1,1.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.rsmimx
    multivalued: false
    alias: rsmimx
    owner: GovSteamFV4
    domain_of:
    - GovSteamFV4
    range: PU
    required: false
  rvgmn:
    name: rvgmn
    description: Minimum value of integral regulator (<i>Rvgmn</i>).  Typical value
      = 0.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.rvgmn
    multivalued: false
    alias: rvgmn
    owner: GovSteamFV4
    domain_of:
    - GovSteamFV4
    range: PU
    required: false
  rvgmx:
    name: rvgmx
    description: Maximum value of integral regulator (<i>Rvgmx</i>).  Typical value
      = 1,2.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.rvgmx
    multivalued: false
    alias: rvgmx
    owner: GovSteamFV4
    domain_of:
    - GovSteamFV4
    range: PU
    required: false
  srmn:
    name: srmn
    description: Minimum valve opening (<i>Srmn</i>).  Typical value = 0.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.srmn
    multivalued: false
    alias: srmn
    owner: GovSteamFV4
    domain_of:
    - GovSteamFV4
    range: PU
    required: false
  srmx:
    name: srmx
    description: Maximum valve opening (<i>Srmx</i>).  Typical value = 1,1.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.srmx
    multivalued: false
    alias: srmx
    owner: GovSteamFV4
    domain_of:
    - GovSteamFV4
    range: PU
    required: false
  srsmp:
    name: srsmp
    description: Intercept valves characteristic discontinuity point (<i>Srsmp</i>).  Typical
      value = 0,43.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.srsmp
    multivalued: false
    alias: srsmp
    owner: GovSteamFV4
    domain_of:
    - GovSteamFV4
    range: PU
    required: false
  svmn:
    name: svmn
    description: Maximum regulator gate closing velocity (<i>Svmn</i>).  Typical value
      = -0,0333.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.svmn
    multivalued: false
    alias: svmn
    owner: GovSteamFV4
    domain_of:
    - GovSteamFV4
    range: float
    required: false
  svmx:
    name: svmx
    description: Maximum regulator gate opening velocity (<i>Svmx</i>).  Typical value
      = 0,0333.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.svmx
    multivalued: false
    alias: svmx
    owner: GovSteamFV4
    domain_of:
    - GovSteamFV4
    range: float
    required: false
  ta:
    name: ta
    description: Control valves rate opening time (<i>Ta</i>) (&gt;= 0).  Typical
      value = 0,8.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:GovSteamFV4.ta
    multivalued: false
    alias: ta
    owner: GovSteamFV4
    domain_of:
    - GovCT1
    - GovCT2
    - GovGAST4
    - GovHydroFrancis
    - GovHydroPelton
    - GovHydroPID2
    - GovHydroWPID
    - GovSteamFV2
    - GovSteamFV3
    - GovSteamFV4
    - ExcIEEEAC1A
    - ExcIEEEAC2A
    - ExcIEEEAC3A
    - ExcIEEEAC4A
    - ExcIEEEAC5A
    - ExcIEEEAC6A
    - ExcIEEEAC8B
    - ExcIEEEDC1A
    - ExcIEEEDC2A
    - ExcIEEEDC4B
    - ExcIEEEST1A
    - ExcIEEEST2A
    - ExcIEEEST3A
    - ExcIEEEST4B
    - ExcAC1A
    - ExcAC2A
    - ExcAC3A
    - ExcAC4A
    - ExcAC5A
    - ExcAC6A
    - ExcAC8B
    - ExcAVR1
    - ExcAVR2
    - ExcAVR5
    - ExcCZ
    - ExcDC1A
    - ExcDC2A
    - ExcDC3A1
    - ExcNI
    - ExcPIC
    - ExcREXS
    - ExcST1A
    - ExcST2A
    - ExcST4B
    - Pss2B
    - PssSB4
    range: Seconds
    required: false
  tam:
    name: tam
    description: Intercept valves rate opening time (<i>Tam</i>) (&gt;= 0).  Typical
      value = 0,8.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.tam
    multivalued: false
    alias: tam
    owner: GovSteamFV4
    domain_of:
    - GovSteamFV4
    range: Seconds
    required: false
  tc:
    name: tc
    description: Control valves rate closing time (<i>Tc</i>) (&gt;= 0).  Typical
      value = 0,5.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:GovSteamFV4.tc
    multivalued: false
    alias: tc
    owner: GovSteamFV4
    domain_of:
    - SynchronousMachineTimeConstantReactance
    - GovCT1
    - GovCT2
    - GovGAST2
    - GovGAST3
    - GovGAST4
    - GovGASTWD
    - GovSteamFV2
    - GovSteamFV3
    - GovSteamFV4
    - ExcIEEEAC1A
    - ExcIEEEAC2A
    - ExcIEEEAC3A
    - ExcIEEEAC4A
    - ExcIEEEAC6A
    - ExcIEEEDC1A
    - ExcIEEEDC2A
    - ExcIEEEST1A
    - ExcIEEEST3A
    - ExcIEEEST5B
    - ExcIEEEST7B
    - ExcAC1A
    - ExcAC2A
    - ExcAC3A
    - ExcAC4A
    - ExcAC5A
    - ExcAC6A
    - ExcCZ
    - ExcDC1A
    - ExcDC2A
    - ExcREXS
    - ExcRQB
    - ExcSEXS
    - ExcSK
    - ExcST1A
    - ExcST2A
    - ExcST3A
    - ExcST7B
    - PssSB4
    range: Seconds
    required: false
  tcm:
    name: tcm
    description: Intercept valves rate closing time (<i>Tcm</i>) (&gt;= 0).  Typical
      value = 0,5.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:GovSteamFV4.tcm
    multivalued: false
    alias: tcm
    owner: GovSteamFV4
    domain_of:
    - GovGAST4
    - GovSteamFV4
    range: Seconds
    required: false
  tdc:
    name: tdc
    description: Derivative time constant of pressure regulator (<i>Tdc</i>) (&gt;=
      0).  Typical value = 90.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.tdc
    multivalued: false
    alias: tdc
    owner: GovSteamFV4
    domain_of:
    - GovSteamFV4
    range: Seconds
    required: false
  tf:
    name: tf
    description: Time constant of steam chest (<i>Tf2</i>) (&gt;= 0).  Typical value
      = 10.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:GovSteamFV4.tf2
    multivalued: false
    alias: tf
    owner: GovSteamFV4
    domain_of:
    - GovGAST2
    - GovGASTWD
    - GovHydro1
    - GovHydro3
    - GovHydroDD
    - GovHydroPID
    - GovSteamEU
    - GovSteamFV4
    - ExcIEEEAC1A
    - ExcIEEEAC2A
    - ExcIEEEAC3A
    - ExcIEEEAC5A
    - ExcIEEEAC7B
    - ExcIEEEDC1A
    - ExcIEEEDC2A
    - ExcIEEEDC4B
    - ExcIEEEST1A
    - ExcIEEEST2A
    - ExcIEEEST7B
    - ExcAC1A
    - ExcAC2A
    - ExcAC3A
    - ExcAC5A
    - ExcAVR1
    - ExcAVR2
    - ExcDC1A
    - ExcDC2A
    - ExcDC3A1
    - ExcNI
    - ExcOEX3T
    - ExcPIC
    - ExcREXS
    - ExcRQB
    - ExcST1A
    - ExcST2A
    - ExcST7B
    - UnderexcLimX1
    - UnderexcLimX2
    - PssPTIST1
    - PssPTIST3
    range: Seconds
    required: false
  thp:
    name: thp
    description: High pressure (HP) time constant of the turbine (<i>Thp</i>) (&gt;=
      0).  Typical value = 0,15.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:GovSteamFV4.thp
    multivalued: false
    alias: thp
    owner: GovSteamFV4
    domain_of:
    - GovSteamEU
    - GovSteamFV4
    range: Seconds
    required: false
  tmp:
    name: tmp
    description: Low pressure (LP) time constant of the turbine (<i>Tmp</i>) (&gt;=
      0).  Typical value = 0,4.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.tmp
    multivalued: false
    alias: tmp
    owner: GovSteamFV4
    domain_of:
    - GovSteamFV4
    range: Seconds
    required: false
  trh:
    name: trh
    description: Reheater  time constant of the turbine (<i>Trh</i>) (&gt;= 0).  Typical
      value = 10.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:GovSteamFV4.trh
    multivalued: false
    alias: trh
    owner: GovSteamFV4
    domain_of:
    - GovSteamEU
    - GovSteamFV4
    - ExcIEEEDC3A
    - ExcDC3A
    range: Seconds
    required: false
  tv:
    name: tv
    description: Boiler time constant (<i>Tv</i>) (&gt;= 0).  Typical value = 60.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:GovSteamFV4.tv
    multivalued: false
    alias: tv
    owner: GovSteamFV4
    domain_of:
    - GovHydroPelton
    - GovSteamFV4
    - LoadMotor
    range: Seconds
    required: false
  ty:
    name: ty
    description: Control valves servo time constant (<i>Ty</i>) (&gt;= 0).  Typical
      value = 0,1.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:GovSteamFV4.ty
    multivalued: false
    alias: ty
    owner: GovSteamFV4
    domain_of:
    - GovGAST3
    - GovGAST4
    - GovSteamFV4
    range: Seconds
    required: false
  y:
    name: y
    description: Coefficient of linearized equations of turbine (Stodola formulation)
      (<i>Y</i>).  Typical value = 0,13.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:GovSteamFV4.y
    multivalued: false
    alias: y
    owner: GovSteamFV4
    domain_of:
    - GovGAST2
    - GovSteamFV4
    range: PU
    required: false
  yhpmn:
    name: yhpmn
    description: Minimum control valve position (<i>Yhpmn</i>).  Typical value = 0.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.yhpmn
    multivalued: false
    alias: yhpmn
    owner: GovSteamFV4
    domain_of:
    - GovSteamFV4
    range: PU
    required: false
  yhpmx:
    name: yhpmx
    description: Maximum control valve position (<i>Yhpmx</i>).  Typical value = 1,1.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.yhpmx
    multivalued: false
    alias: yhpmx
    owner: GovSteamFV4
    domain_of:
    - GovSteamFV4
    range: PU
    required: false
  ympmn:
    name: ympmn
    description: Minimum intercept valve position (<i>Ympmn</i>).  Typical value =
      0.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.ympmn
    multivalued: false
    alias: ympmn
    owner: GovSteamFV4
    domain_of:
    - GovSteamFV4
    range: PU
    required: false
  ympmx:
    name: ympmx
    description: Maximum intercept valve position (<i>Ympmx</i>).  Typical value =
      1,1.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GovSteamFV4.ympmx
    multivalued: false
    alias: ympmx
    owner: GovSteamFV4
    domain_of:
    - GovSteamFV4
    range: PU
    required: false
  asynchronous_machine_dynamics:
    name: asynchronous_machine_dynamics
    description: Asynchronous machine model with which this turbine-governor model
      is associated. TurbineGovernorDynamics shall have either an association to SynchronousMachineDynamics
      or to AsynchronousMachineDynamics.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:TurbineGovernorDynamics.AsynchronousMachineDynamics
    multivalued: false
    alias: asynchronous_machine_dynamics
    owner: GovSteamFV4
    domain_of:
    - WindTurbineType1or2Dynamics
    - TurbineGovernorDynamics
    - MechanicalLoadDynamics
    - AsynchronousMachine
    range: AsynchronousMachineDynamics
    required: false
  turbine_load_controller_dynamics:
    name: turbine_load_controller_dynamics
    description: Turbine load controller providing input to this turbine-governor.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:TurbineGovernorDynamics.TurbineLoadControllerDynamics
    multivalued: false
    alias: turbine_load_controller_dynamics
    owner: GovSteamFV4
    domain_of:
    - TurbineGovernorDynamics
    range: TurbineLoadControllerDynamics
    required: false
  synchronous_machine_dynamics:
    name: synchronous_machine_dynamics
    description: Synchronous machine model with which this turbine-governor model
      is associated. TurbineGovernorDynamics shall have either an association to SynchronousMachineDynamics
      or to AsynchronousMachineDynamics.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:TurbineGovernorDynamics.SynchronousMachineDynamics
    multivalued: false
    alias: synchronous_machine_dynamics
    owner: GovSteamFV4
    domain_of:
    - SynchronousMachine
    - GenICompensationForGenJ
    - ExcitationSystemDynamics
    - TurbineGovernorDynamics
    - MechanicalLoadDynamics
    range: SynchronousMachineDynamics
    required: false
  enabled:
    name: enabled
    description: "Function block used indicator.\r\ntrue = use of function block is\
      \ enabled\r\nfalse = use of function block is disabled."
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:DynamicsFunctionBlock.enabled
    multivalued: false
    alias: enabled
    owner: GovSteamFV4
    domain_of:
    - ProtectiveAction
    - EndDeviceFunction
    - RegulatingControl
    - DynamicsFunctionBlock
    range: boolean
    required: false
  alias_name:
    name: alias_name
    description: "The aliasName is free text human readable name of the object alternative\
      \ to IdentifiedObject.name. It may be non unique and may not correlate to a\
      \ naming hierarchy.\r\nThe attribute aliasName is retained because of backwards\
      \ compatibility between CIM relases. It is however recommended to replace aliasName\
      \ with the Name class as aliasName is planned for retirement at a future time.\r\
      \n\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.aliasName
    multivalued: false
    alias: alias_name
    owner: GovSteamFV4
    domain_of:
    - IdentifiedObject
    range: string
    required: false
  description:
    name: description
    description: The description is a free human readable text describing or naming
      the object. It may be non unique and may not correlate to a naming hierarchy.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.description
    multivalued: false
    alias: description
    owner: GovSteamFV4
    domain_of:
    - IdentifiedObject
    - NameType
    - NameTypeAuthority
    - DataSet
    - SwitchingStepGroup
    - AreaReserveSpec
    range: string
    required: false
  m_rid:
    name: m_rid
    description: "Master resource identifier issued by a model authority. The mRID\
      \ is unique within an exchange context. Global uniqueness is easily achieved\
      \ by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is\
      \ strongly recommended.\r\nFor CIMXML data files in RDF syntax conforming to\
      \ IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify\
      \ CIM object elements."
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.mRID
    multivalued: false
    alias: m_rid
    owner: GovSteamFV4
    domain_of:
    - IdentifiedObject
    - DataSet
    range: string
    required: false
  diagram_objects:
    name: diagram_objects
    description: The diagram objects that are associated with the domain object.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.DiagramObjects
    multivalued: true
    alias: diagram_objects
    owner: GovSteamFV4
    domain_of:
    - IdentifiedObject
    range: DiagramObject
    required: false
  instance_set:
    name: instance_set
    description: Dataset containing the data objects.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.InstanceSet
    multivalued: false
    alias: instance_set
    owner: GovSteamFV4
    domain_of:
    - IdentifiedObject
    range: InstanceSet
    required: true
  names:
    name: names
    description: All names of this identified object.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.Names
    multivalued: true
    alias: names
    owner: GovSteamFV4
    domain_of:
    - IdentifiedObject
    - NameType
    range: Name
    required: false
  properties_cimdata_object:
    name: properties_cimdata_object
    description: The single CIM data object in the appropriate dataset context.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.PropertiesCIMDataObject
    multivalued: false
    alias: properties_cimdata_object
    owner: GovSteamFV4
    domain_of:
    - IdentifiedObject
    range: ChangeSetMember
    required: false
  targeting_cimdata_object:
    name: targeting_cimdata_object
    description: Data objects registered.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.TargetingCIMDataObject
    multivalued: true
    alias: targeting_cimdata_object
    owner: GovSteamFV4
    domain_of:
    - IdentifiedObject
    range: ChangeSetMember
    required: false
class_uri: cim:GovSteamFV4