Class: GovHydroR
_Fourth order lead-lag governor and hydro turbine. _
URI: cim:GovHydroR
classDiagram
class GovHydroR
TurbineGovernorDynamics <|-- GovHydroR
GovHydroR : alias_name
GovHydroR : asynchronous_machine_dynamics
GovHydroR --> AsynchronousMachineDynamics : asynchronous_machine_dynamics
GovHydroR : at
GovHydroR --> PU : at
GovHydroR : db
GovHydroR --> ActivePower : db
GovHydroR : description
GovHydroR : diagram_objects
GovHydroR --> DiagramObject : diagram_objects
GovHydroR : dturb
GovHydroR --> PU : dturb
GovHydroR : enabled
GovHydroR : eps
GovHydroR --> Frequency : eps
GovHydroR : gmax
GovHydroR --> PU : gmax
GovHydroR : gmin
GovHydroR --> PU : gmin
GovHydroR : gv
GovHydroR --> PU : gv
GovHydroR : h
GovHydroR --> PU : h
GovHydroR : input_signal
GovHydroR : instance_set
GovHydroR --> InstanceSet : instance_set
GovHydroR : kg
GovHydroR --> PU : kg
GovHydroR : ki
GovHydroR --> PU : ki
GovHydroR : m_rid
GovHydroR : mwbase
GovHydroR --> ActivePower : mwbase
GovHydroR : names
GovHydroR --> Name : names
GovHydroR : pgv
GovHydroR --> PU : pgv
GovHydroR : pmax
GovHydroR --> PU : pmax
GovHydroR : pmin
GovHydroR --> PU : pmin
GovHydroR : properties_cimdata_object
GovHydroR --> ChangeSetMember : properties_cimdata_object
GovHydroR : qnl
GovHydroR --> PU : qnl
GovHydroR : r
GovHydroR --> PU : r
GovHydroR : synchronous_machine_dynamics
GovHydroR --> SynchronousMachineDynamics : synchronous_machine_dynamics
GovHydroR : t
GovHydroR --> Seconds : t
GovHydroR : targeting_cimdata_object
GovHydroR --> ChangeSetMember : targeting_cimdata_object
GovHydroR : td
GovHydroR --> Seconds : td
GovHydroR : tp
GovHydroR --> Seconds : tp
GovHydroR : tt
GovHydroR --> Seconds : tt
GovHydroR : turbine_load_controller_dynamics
GovHydroR --> TurbineLoadControllerDynamics : turbine_load_controller_dynamics
GovHydroR : tw
GovHydroR --> Seconds : tw
GovHydroR : velcl
GovHydroR : velop
Inheritance
Slots
| Name | Cardinality and Range | Description | Inheritance |
|---|---|---|---|
| at | 0..1 PU |
Turbine gain (At) | direct |
| db | 0..1 ActivePower |
Unintentional dead-band (db2) | direct |
| dturb | 0..1 PU |
Turbine damping factor (Dturb) | direct |
| eps | 0..1 Frequency |
Intentional db hysteresis (eps) | direct |
| gmax | 0..1 PU |
Maximum governor output (Gmax) (> GovHydroR | direct |
| gmin | 0..1 PU |
Minimum governor output (Gmin) (< GovHydroR | direct |
| gv | 0..1 PU |
Nonlinear gain point 6, PU gv (Gv6) | direct |
| h | 0..1 PU |
Turbine nominal head (H0) | direct |
| input_signal | 0..1 Boolean |
Input signal switch (Flag) | direct |
| kg | 0..1 PU |
Gate servo gain (Kg) | direct |
| ki | 0..1 PU |
Integral gain (Ki) | direct |
| mwbase | 0..1 ActivePower |
Base for power values (MWbase) (> 0) | direct |
| pgv | 0..1 PU |
Nonlinear gain point 6, PU power (Pgv6) | direct |
| pmax | 0..1 PU |
Maximum gate opening, PU of MWbase (Pmax) (> GovHydroR | direct |
| pmin | 0..1 PU |
Minimum gate opening, PU of MWbase (Pmin) (< GovHydroR | direct |
| qnl | 0..1 PU |
No-load turbine flow at nominal head (Qnl) | direct |
| r | 0..1 PU |
Steady-state droop (R) | direct |
| t | 0..1 Seconds |
Lag time constant 4 (T8) (>= 0) | direct |
| td | 0..1 Seconds |
Input filter time constant (Td) (>= 0) | direct |
| tp | 0..1 Seconds |
Gate servo time constant (Tp) (>= 0) | direct |
| tt | 0..1 Seconds |
Power feedback time constant (Tt) (>= 0) | direct |
| tw | 0..1 Seconds |
Water inertia time constant (Tw) (> 0) | direct |
| velcl | 0..1 Float |
Maximum gate closing velocity (Velcl) | direct |
| velop | 0..1 Float |
Maximum gate opening velocity (Velop) | direct |
| asynchronous_machine_dynamics | 0..1 AsynchronousMachineDynamics |
Asynchronous machine model with which this turbine-governor model is associat... | TurbineGovernorDynamics |
| turbine_load_controller_dynamics | 0..1 TurbineLoadControllerDynamics |
Turbine load controller providing input to this turbine-governor | TurbineGovernorDynamics |
| synchronous_machine_dynamics | 0..1 SynchronousMachineDynamics |
Synchronous machine model with which this turbine-governor model is associate... | TurbineGovernorDynamics |
| enabled | 0..1 Boolean |
Function block used indicator | DynamicsFunctionBlock |
| alias_name | 0..1 String |
The aliasName is free text human readable name of the object alternative to I... | IdentifiedObject |
| description | 0..1 String |
The description is a free human readable text describing or naming the object | IdentifiedObject |
| m_rid | 0..1 String |
Master resource identifier issued by a model authority | IdentifiedObject |
| diagram_objects | 0..* DiagramObject |
The diagram objects that are associated with the domain object | IdentifiedObject |
| instance_set | 1..1 InstanceSet |
Dataset containing the data objects | IdentifiedObject |
| names | 0..* Name |
All names of this identified object | IdentifiedObject |
| properties_cimdata_object | 0..1 ChangeSetMember |
The single CIM data object in the appropriate dataset context | IdentifiedObject |
| targeting_cimdata_object | 0..* ChangeSetMember |
Data objects registered | IdentifiedObject |
Identifier and Mapping Information
Schema Source
- from schema: https://cim.ucaiug.io/ns#TC57CIM
Mappings
| Mapping Type | Mapped Value |
|---|---|
| self | cim:GovHydroR |
| native | cim:GovHydroR |
LinkML Source
Direct
name: GovHydroR
description: 'Fourth order lead-lag governor and hydro turbine. '
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
is_a: TurbineGovernorDynamics
attributes:
at:
name: at
description: Turbine gain (<i>At</i>). Typical value = 1,2.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroR.at
multivalued: false
domain_of:
- GovGAST
- GovHydro1
- GovHydro3
- GovHydro4
- GovHydroR
range: PU
required: false
db:
name: db
description: Unintentional dead-band (<i>db2</i>). Unit = MW. Typical value
= 0.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroR.db2
multivalued: false
domain_of:
- GovCT1
- GovCT2
- GovGAST1
- GovHydro2
- GovHydro3
- GovHydro4
- GovHydroDD
- GovHydroFrancis
- GovHydroPelton
- GovHydroPID
- GovHydroR
- GovHydroWEH
- GovSteam1
- GovSteamEU
- TurbLCFB1
range: ActivePower
required: false
dturb:
name: dturb
description: Turbine damping factor (<i>Dturb</i>). Typical value = 0,2.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroR.dturb
multivalued: false
domain_of:
- GovGAST
- GovHydro1
- GovHydro3
- GovHydro4
- GovHydroR
- GovHydroWEH
range: PU
required: false
eps:
name: eps
description: Intentional db hysteresis (<i>eps</i>). Unit = Hz. Typical value
= 0.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroR.eps
multivalued: false
domain_of:
- GovGAST1
- GovHydro2
- GovHydro3
- GovHydro4
- GovHydroDD
- GovHydroPID
- GovHydroR
- GovSteam1
range: Frequency
required: false
gmax:
name: gmax
description: Maximum governor output (<i>Gmax</i>) (> GovHydroR.gmin). Typical
value = 1,05.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroR.gmax
multivalued: false
domain_of:
- GovHydro1
- GovHydro4
- GovHydroDD
- GovHydroPID2
- GovHydroR
- GovHydroWEH
range: PU
required: false
gmin:
name: gmin
description: Minimum governor output (<i>Gmin</i>) (< GovHydroR.gmax). Typical
value = -0,05.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroR.gmin
multivalued: false
domain_of:
- GovHydro1
- GovHydro4
- GovHydroDD
- GovHydroPID2
- GovHydroR
- GovHydroWEH
range: PU
required: false
gv:
name: gv
description: Nonlinear gain point 6, PU gv (<i>Gv6</i>). Typical value = 0.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroR.gv6
multivalued: false
domain_of:
- GovHydroIEEE2
- GovGAST1
- GovHydro2
- GovHydro3
- GovHydro4
- GovHydroDD
- GovHydroPID
- GovHydroR
- GovHydroWEH
- GovHydroWPID
- GovSteam1
- GovSteamFV3
range: PU
required: false
h:
name: h
description: Turbine nominal head (<i>H0</i>). Typical value = 1.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroR.h0
multivalued: false
domain_of:
- GovHydro3
- GovHydroFrancis
- GovHydroPelton
- GovHydroR
- LoadComposite
- LoadMotor
range: PU
required: false
input_signal:
name: input_signal
description: "Input signal switch (<i>Flag</i>).\r\ntrue = <i>Pe</i> input is\
\ used\r\nfalse = feedback is received from <i>CV</i>.\r\n<i>Flag</i> is normally\
\ dependent on <i>Tt</i>. If <i>Tt </i>is zero, <i>Flag</i> is set to false.\
\ If <i>Tt</i> is not zero, <i>Flag</i> is set to true. \r\nTypical value =\
\ true."
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroR.inputSignal
multivalued: false
domain_of:
- GovHydroDD
- GovHydroPID
- GovHydroR
range: boolean
required: false
kg:
name: kg
description: Gate servo gain (<i>Kg</i>). Typical value = 2.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroR.kg
multivalued: false
domain_of:
- GovHydro3
- GovHydroDD
- GovHydroFrancis
- GovHydroPelton
- GovHydroPID
- GovHydroR
- GovSteamBB
- ExcIEEEST3A
- ExcIEEEST4B
- ExcIEEEST6B
- ExcST3A
- ExcST4B
- ExcST6B
range: PU
required: false
ki:
name: ki
description: Integral gain (<i>Ki</i>). Typical value = 0,5.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroR.ki
multivalued: false
domain_of:
- GovGASTWD
- GovHydro3
- GovHydroDD
- GovHydroPID
- GovHydroPID2
- GovHydroR
- GovHydroWEH
- GovHydroWPID
- TurbLCFB1
- ExcIEEEDC4B
- ExcIEEEST2A
- ExcIEEEST3A
- ExcIEEEST4B
- ExcDC3A1
- ExcHU
- ExcPIC
- ExcRQB
- ExcST2A
- ExcST3A
- ExcST4B
- PssIEEE4B
- PssRQB
- PFVArType2IEEEPFController
- PFVArType2IEEEVArController
- PFVArType2Common1
range: PU
required: false
mwbase:
name: mwbase
description: Base for power values (<i>MWbase</i>) (> 0). Unit = MW.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroR.mwbase
multivalued: false
domain_of:
- GovHydroIEEE0
- GovHydroIEEE2
- GovSteamIEEE1
- GovCT1
- GovCT2
- GovGAST
- GovGAST1
- GovGAST2
- GovGASTWD
- GovHydro1
- GovHydro2
- GovHydro3
- GovHydro4
- GovHydroDD
- GovHydroPID
- GovHydroPID2
- GovHydroR
- GovHydroWEH
- GovHydroWPID
- GovSteam0
- GovSteam1
- GovSteamCC
- GovSteamEU
- GovSteamFV2
- GovSteamFV3
- GovSteamSGO
- TurbLCFB1
range: ActivePower
required: false
pgv:
name: pgv
description: Nonlinear gain point 6, PU power (<i>Pgv6</i>). Typical value =
0.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroR.pgv6
multivalued: false
domain_of:
- GovHydroIEEE2
- GovGAST1
- GovHydro2
- GovHydro3
- GovHydro4
- GovHydroDD
- GovHydroPID
- GovHydroR
- GovHydroWPID
- GovSteam1
- GovSteamFV3
range: PU
required: false
pmax:
name: pmax
description: Maximum gate opening, PU of <i>MWbase</i> (<i>Pmax</i>) (> GovHydroR.pmin). Typical
value = 1.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroR.pmax
multivalued: false
domain_of:
- GovHydroIEEE0
- GovHydroIEEE2
- GovSteamIEEE1
- GovHydro2
- GovHydro3
- GovHydroDD
- GovHydroPID
- GovHydroR
- GovHydroWPID
- GovSteam1
- GovSteam2
- GovSteamBB
- GovSteamEU
- GovSteamFV3
- GovSteamSGO
range: PU
required: false
pmin:
name: pmin
description: Minimum gate opening, PU of <i>MWbase</i> (<i>Pmin</i>) (< GovHydroR.pmax). Typical
value = 0.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroR.pmin
multivalued: false
domain_of:
- GovHydroIEEE0
- GovHydroIEEE2
- GovSteamIEEE1
- GovHydro2
- GovHydro3
- GovHydroDD
- GovHydroPID
- GovHydroR
- GovHydroWPID
- GovSteam1
- GovSteam2
- GovSteamBB
- GovSteamFV3
- GovSteamSGO
- Pss1
- Pss5
- PssPTIST3
- WindPitchContPowerIEC
range: PU
required: false
qnl:
name: qnl
description: No-load turbine flow at nominal head (<i>Qnl</i>). Typical value
= 0,08.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroR.qnl
multivalued: false
domain_of:
- GovHydro1
- GovHydro3
- GovHydro4
- GovHydroR
range: PU
required: false
r:
name: r
description: Steady-state droop (<i>R</i>). Typical value = 0,05.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroR.r
multivalued: false
domain_of:
- MutualCoupling
- TransformerMeshImpedance
- TransformerEndInfo
- PowerTransformerEnd
- ACLineSegment
- SynchronousMachine
- EquivalentInjection
- PowerElectronicsConnection
- SeriesCompensator
- TransformerStarImpedance
- TapChangerTablePoint
- PerLengthSequenceImpedance
- PhaseImpedanceData
- EarthFaultCompensator
- EnergySource
- EquivalentBranch
- DCGround
- GovCT1
- GovCT2
- GovGAST
- GovGAST1
- GovHydroDD
- GovHydroPID
- GovHydroR
- GovSteam0
- GovSteamFV2
- ExcNI
- UnderexcLimX2
range: PU
required: false
t:
name: t
description: Lag time constant 4 (<i>T8</i>) (>= 0). Typical value = 0,05.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroR.t8
multivalued: false
domain_of:
- GovHydroIEEE0
- GovSteamIEEE1
- GovGAST
- GovGAST1
- GovGAST2
- GovGASTWD
- GovHydroR
- GovSteam0
- GovSteam1
- GovSteam2
- GovSteamBB
- GovSteamFV2
- GovSteamFV3
- GovSteamSGO
- ExcIEEEST5B
- ExcANS
- ExcAVR3
- ExcAVR4
- ExcAVR7
- ExcBBC
- ExcOEX3T
- OverexcLimX1
- OverexcLimX2
- PssIEEE1A
- PssIEEE2B
- PssIEEE3B
- Pss1
- Pss1A
- Pss2B
- Pss2ST
- PssPTIST1
- PssPTIST3
- PssSH
- PssSK
- PssSTAB2A
- PssWECC
- WindPitchContPowerIEC
range: Seconds
required: false
td:
name: td
description: Input filter time constant (<i>Td</i>) (>= 0). Typical value
= 0,05.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroR.td
multivalued: false
domain_of:
- GovGAST3
- GovGASTWD
- GovHydro3
- GovHydroDD
- GovHydroFrancis
- GovHydroPID
- GovHydroR
- GovHydroWEH
- GovSteamBB
- ExcIEEEDC4B
- PssSB4
- PssSH
- DiscExcContIEEEDEC1A
- DiscExcContIEEEDEC2A
range: Seconds
required: false
tp:
name: tp
description: Gate servo time constant (<i>Tp</i>) (>= 0). Typical value =
0,05.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroR.tp
multivalued: false
domain_of:
- GovHydroIEEE2
- GovHydro2
- GovHydro3
- GovHydro4
- GovHydroDD
- GovHydroPID
- GovHydroR
- GovHydroWEH
- GovSteamEU
- ExcREXS
- ExcSK
- PssPTIST1
- PssPTIST3
- LoadGenericNonLinear
range: Seconds
required: false
tt:
name: tt
description: Power feedback time constant (<i>Tt</i>) (>= 0). Typical value
= 0.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroR.tt
multivalued: false
domain_of:
- GovGAST2
- GovGAST3
- GovGASTWD
- GovHydro3
- GovHydroDD
- GovHydroPID
- GovHydroR
- GovSteamFV2
- PssSB4
range: Seconds
required: false
tw:
name: tw
description: Water inertia time constant (<i>Tw</i>) (> 0). Typical value
= 1.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroR.tw
multivalued: false
domain_of:
- GovHydroIEEE2
- GovHydro1
- GovHydro2
- GovHydro3
- GovHydro4
- GovHydroPID2
- GovHydroR
- GovHydroWEH
- GovHydroWPID
- GovSteamEU
- PssIEEE2B
- PssIEEE3B
- Pss2B
- Pss5
- DiscExcContIEEEDEC1A
range: Seconds
required: false
velcl:
name: velcl
description: Maximum gate closing velocity (<i>Velcl</i>). Unit = PU / s. Typical
value = -0,2.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroR.velcl
multivalued: false
domain_of:
- GovHydro3
- GovHydroDD
- GovHydroPID
- GovHydroR
range: float
required: false
velop:
name: velop
description: Maximum gate opening velocity (<i>Velop</i>). Unit = PU / s. Typical
value = 0,2.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroR.velop
multivalued: false
domain_of:
- GovHydro3
- GovHydroDD
- GovHydroPID
- GovHydroR
range: float
required: false
class_uri: cim:GovHydroR
Induced
name: GovHydroR
description: 'Fourth order lead-lag governor and hydro turbine. '
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
is_a: TurbineGovernorDynamics
attributes:
at:
name: at
description: Turbine gain (<i>At</i>). Typical value = 1,2.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroR.at
multivalued: false
alias: at
owner: GovHydroR
domain_of:
- GovGAST
- GovHydro1
- GovHydro3
- GovHydro4
- GovHydroR
range: PU
required: false
db:
name: db
description: Unintentional dead-band (<i>db2</i>). Unit = MW. Typical value
= 0.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroR.db2
multivalued: false
alias: db
owner: GovHydroR
domain_of:
- GovCT1
- GovCT2
- GovGAST1
- GovHydro2
- GovHydro3
- GovHydro4
- GovHydroDD
- GovHydroFrancis
- GovHydroPelton
- GovHydroPID
- GovHydroR
- GovHydroWEH
- GovSteam1
- GovSteamEU
- TurbLCFB1
range: ActivePower
required: false
dturb:
name: dturb
description: Turbine damping factor (<i>Dturb</i>). Typical value = 0,2.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroR.dturb
multivalued: false
alias: dturb
owner: GovHydroR
domain_of:
- GovGAST
- GovHydro1
- GovHydro3
- GovHydro4
- GovHydroR
- GovHydroWEH
range: PU
required: false
eps:
name: eps
description: Intentional db hysteresis (<i>eps</i>). Unit = Hz. Typical value
= 0.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroR.eps
multivalued: false
alias: eps
owner: GovHydroR
domain_of:
- GovGAST1
- GovHydro2
- GovHydro3
- GovHydro4
- GovHydroDD
- GovHydroPID
- GovHydroR
- GovSteam1
range: Frequency
required: false
gmax:
name: gmax
description: Maximum governor output (<i>Gmax</i>) (> GovHydroR.gmin). Typical
value = 1,05.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroR.gmax
multivalued: false
alias: gmax
owner: GovHydroR
domain_of:
- GovHydro1
- GovHydro4
- GovHydroDD
- GovHydroPID2
- GovHydroR
- GovHydroWEH
range: PU
required: false
gmin:
name: gmin
description: Minimum governor output (<i>Gmin</i>) (< GovHydroR.gmax). Typical
value = -0,05.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroR.gmin
multivalued: false
alias: gmin
owner: GovHydroR
domain_of:
- GovHydro1
- GovHydro4
- GovHydroDD
- GovHydroPID2
- GovHydroR
- GovHydroWEH
range: PU
required: false
gv:
name: gv
description: Nonlinear gain point 6, PU gv (<i>Gv6</i>). Typical value = 0.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroR.gv6
multivalued: false
alias: gv
owner: GovHydroR
domain_of:
- GovHydroIEEE2
- GovGAST1
- GovHydro2
- GovHydro3
- GovHydro4
- GovHydroDD
- GovHydroPID
- GovHydroR
- GovHydroWEH
- GovHydroWPID
- GovSteam1
- GovSteamFV3
range: PU
required: false
h:
name: h
description: Turbine nominal head (<i>H0</i>). Typical value = 1.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroR.h0
multivalued: false
alias: h
owner: GovHydroR
domain_of:
- GovHydro3
- GovHydroFrancis
- GovHydroPelton
- GovHydroR
- LoadComposite
- LoadMotor
range: PU
required: false
input_signal:
name: input_signal
description: "Input signal switch (<i>Flag</i>).\r\ntrue = <i>Pe</i> input is\
\ used\r\nfalse = feedback is received from <i>CV</i>.\r\n<i>Flag</i> is normally\
\ dependent on <i>Tt</i>. If <i>Tt </i>is zero, <i>Flag</i> is set to false.\
\ If <i>Tt</i> is not zero, <i>Flag</i> is set to true. \r\nTypical value =\
\ true."
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroR.inputSignal
multivalued: false
alias: input_signal
owner: GovHydroR
domain_of:
- GovHydroDD
- GovHydroPID
- GovHydroR
range: boolean
required: false
kg:
name: kg
description: Gate servo gain (<i>Kg</i>). Typical value = 2.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroR.kg
multivalued: false
alias: kg
owner: GovHydroR
domain_of:
- GovHydro3
- GovHydroDD
- GovHydroFrancis
- GovHydroPelton
- GovHydroPID
- GovHydroR
- GovSteamBB
- ExcIEEEST3A
- ExcIEEEST4B
- ExcIEEEST6B
- ExcST3A
- ExcST4B
- ExcST6B
range: PU
required: false
ki:
name: ki
description: Integral gain (<i>Ki</i>). Typical value = 0,5.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroR.ki
multivalued: false
alias: ki
owner: GovHydroR
domain_of:
- GovGASTWD
- GovHydro3
- GovHydroDD
- GovHydroPID
- GovHydroPID2
- GovHydroR
- GovHydroWEH
- GovHydroWPID
- TurbLCFB1
- ExcIEEEDC4B
- ExcIEEEST2A
- ExcIEEEST3A
- ExcIEEEST4B
- ExcDC3A1
- ExcHU
- ExcPIC
- ExcRQB
- ExcST2A
- ExcST3A
- ExcST4B
- PssIEEE4B
- PssRQB
- PFVArType2IEEEPFController
- PFVArType2IEEEVArController
- PFVArType2Common1
range: PU
required: false
mwbase:
name: mwbase
description: Base for power values (<i>MWbase</i>) (> 0). Unit = MW.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroR.mwbase
multivalued: false
alias: mwbase
owner: GovHydroR
domain_of:
- GovHydroIEEE0
- GovHydroIEEE2
- GovSteamIEEE1
- GovCT1
- GovCT2
- GovGAST
- GovGAST1
- GovGAST2
- GovGASTWD
- GovHydro1
- GovHydro2
- GovHydro3
- GovHydro4
- GovHydroDD
- GovHydroPID
- GovHydroPID2
- GovHydroR
- GovHydroWEH
- GovHydroWPID
- GovSteam0
- GovSteam1
- GovSteamCC
- GovSteamEU
- GovSteamFV2
- GovSteamFV3
- GovSteamSGO
- TurbLCFB1
range: ActivePower
required: false
pgv:
name: pgv
description: Nonlinear gain point 6, PU power (<i>Pgv6</i>). Typical value =
0.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroR.pgv6
multivalued: false
alias: pgv
owner: GovHydroR
domain_of:
- GovHydroIEEE2
- GovGAST1
- GovHydro2
- GovHydro3
- GovHydro4
- GovHydroDD
- GovHydroPID
- GovHydroR
- GovHydroWPID
- GovSteam1
- GovSteamFV3
range: PU
required: false
pmax:
name: pmax
description: Maximum gate opening, PU of <i>MWbase</i> (<i>Pmax</i>) (> GovHydroR.pmin). Typical
value = 1.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroR.pmax
multivalued: false
alias: pmax
owner: GovHydroR
domain_of:
- GovHydroIEEE0
- GovHydroIEEE2
- GovSteamIEEE1
- GovHydro2
- GovHydro3
- GovHydroDD
- GovHydroPID
- GovHydroR
- GovHydroWPID
- GovSteam1
- GovSteam2
- GovSteamBB
- GovSteamEU
- GovSteamFV3
- GovSteamSGO
range: PU
required: false
pmin:
name: pmin
description: Minimum gate opening, PU of <i>MWbase</i> (<i>Pmin</i>) (< GovHydroR.pmax). Typical
value = 0.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroR.pmin
multivalued: false
alias: pmin
owner: GovHydroR
domain_of:
- GovHydroIEEE0
- GovHydroIEEE2
- GovSteamIEEE1
- GovHydro2
- GovHydro3
- GovHydroDD
- GovHydroPID
- GovHydroR
- GovHydroWPID
- GovSteam1
- GovSteam2
- GovSteamBB
- GovSteamFV3
- GovSteamSGO
- Pss1
- Pss5
- PssPTIST3
- WindPitchContPowerIEC
range: PU
required: false
qnl:
name: qnl
description: No-load turbine flow at nominal head (<i>Qnl</i>). Typical value
= 0,08.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroR.qnl
multivalued: false
alias: qnl
owner: GovHydroR
domain_of:
- GovHydro1
- GovHydro3
- GovHydro4
- GovHydroR
range: PU
required: false
r:
name: r
description: Steady-state droop (<i>R</i>). Typical value = 0,05.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroR.r
multivalued: false
alias: r
owner: GovHydroR
domain_of:
- MutualCoupling
- TransformerMeshImpedance
- TransformerEndInfo
- PowerTransformerEnd
- ACLineSegment
- SynchronousMachine
- EquivalentInjection
- PowerElectronicsConnection
- SeriesCompensator
- TransformerStarImpedance
- TapChangerTablePoint
- PerLengthSequenceImpedance
- PhaseImpedanceData
- EarthFaultCompensator
- EnergySource
- EquivalentBranch
- DCGround
- GovCT1
- GovCT2
- GovGAST
- GovGAST1
- GovHydroDD
- GovHydroPID
- GovHydroR
- GovSteam0
- GovSteamFV2
- ExcNI
- UnderexcLimX2
range: PU
required: false
t:
name: t
description: Lag time constant 4 (<i>T8</i>) (>= 0). Typical value = 0,05.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroR.t8
multivalued: false
alias: t
owner: GovHydroR
domain_of:
- GovHydroIEEE0
- GovSteamIEEE1
- GovGAST
- GovGAST1
- GovGAST2
- GovGASTWD
- GovHydroR
- GovSteam0
- GovSteam1
- GovSteam2
- GovSteamBB
- GovSteamFV2
- GovSteamFV3
- GovSteamSGO
- ExcIEEEST5B
- ExcANS
- ExcAVR3
- ExcAVR4
- ExcAVR7
- ExcBBC
- ExcOEX3T
- OverexcLimX1
- OverexcLimX2
- PssIEEE1A
- PssIEEE2B
- PssIEEE3B
- Pss1
- Pss1A
- Pss2B
- Pss2ST
- PssPTIST1
- PssPTIST3
- PssSH
- PssSK
- PssSTAB2A
- PssWECC
- WindPitchContPowerIEC
range: Seconds
required: false
td:
name: td
description: Input filter time constant (<i>Td</i>) (>= 0). Typical value
= 0,05.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroR.td
multivalued: false
alias: td
owner: GovHydroR
domain_of:
- GovGAST3
- GovGASTWD
- GovHydro3
- GovHydroDD
- GovHydroFrancis
- GovHydroPID
- GovHydroR
- GovHydroWEH
- GovSteamBB
- ExcIEEEDC4B
- PssSB4
- PssSH
- DiscExcContIEEEDEC1A
- DiscExcContIEEEDEC2A
range: Seconds
required: false
tp:
name: tp
description: Gate servo time constant (<i>Tp</i>) (>= 0). Typical value =
0,05.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroR.tp
multivalued: false
alias: tp
owner: GovHydroR
domain_of:
- GovHydroIEEE2
- GovHydro2
- GovHydro3
- GovHydro4
- GovHydroDD
- GovHydroPID
- GovHydroR
- GovHydroWEH
- GovSteamEU
- ExcREXS
- ExcSK
- PssPTIST1
- PssPTIST3
- LoadGenericNonLinear
range: Seconds
required: false
tt:
name: tt
description: Power feedback time constant (<i>Tt</i>) (>= 0). Typical value
= 0.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroR.tt
multivalued: false
alias: tt
owner: GovHydroR
domain_of:
- GovGAST2
- GovGAST3
- GovGASTWD
- GovHydro3
- GovHydroDD
- GovHydroPID
- GovHydroR
- GovSteamFV2
- PssSB4
range: Seconds
required: false
tw:
name: tw
description: Water inertia time constant (<i>Tw</i>) (> 0). Typical value
= 1.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroR.tw
multivalued: false
alias: tw
owner: GovHydroR
domain_of:
- GovHydroIEEE2
- GovHydro1
- GovHydro2
- GovHydro3
- GovHydro4
- GovHydroPID2
- GovHydroR
- GovHydroWEH
- GovHydroWPID
- GovSteamEU
- PssIEEE2B
- PssIEEE3B
- Pss2B
- Pss5
- DiscExcContIEEEDEC1A
range: Seconds
required: false
velcl:
name: velcl
description: Maximum gate closing velocity (<i>Velcl</i>). Unit = PU / s. Typical
value = -0,2.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroR.velcl
multivalued: false
alias: velcl
owner: GovHydroR
domain_of:
- GovHydro3
- GovHydroDD
- GovHydroPID
- GovHydroR
range: float
required: false
velop:
name: velop
description: Maximum gate opening velocity (<i>Velop</i>). Unit = PU / s. Typical
value = 0,2.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroR.velop
multivalued: false
alias: velop
owner: GovHydroR
domain_of:
- GovHydro3
- GovHydroDD
- GovHydroPID
- GovHydroR
range: float
required: false
asynchronous_machine_dynamics:
name: asynchronous_machine_dynamics
description: Asynchronous machine model with which this turbine-governor model
is associated. TurbineGovernorDynamics shall have either an association to SynchronousMachineDynamics
or to AsynchronousMachineDynamics.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:TurbineGovernorDynamics.AsynchronousMachineDynamics
multivalued: false
alias: asynchronous_machine_dynamics
owner: GovHydroR
domain_of:
- WindTurbineType1or2Dynamics
- TurbineGovernorDynamics
- MechanicalLoadDynamics
- AsynchronousMachine
range: AsynchronousMachineDynamics
required: false
turbine_load_controller_dynamics:
name: turbine_load_controller_dynamics
description: Turbine load controller providing input to this turbine-governor.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:TurbineGovernorDynamics.TurbineLoadControllerDynamics
multivalued: false
alias: turbine_load_controller_dynamics
owner: GovHydroR
domain_of:
- TurbineGovernorDynamics
range: TurbineLoadControllerDynamics
required: false
synchronous_machine_dynamics:
name: synchronous_machine_dynamics
description: Synchronous machine model with which this turbine-governor model
is associated. TurbineGovernorDynamics shall have either an association to SynchronousMachineDynamics
or to AsynchronousMachineDynamics.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:TurbineGovernorDynamics.SynchronousMachineDynamics
multivalued: false
alias: synchronous_machine_dynamics
owner: GovHydroR
domain_of:
- SynchronousMachine
- GenICompensationForGenJ
- ExcitationSystemDynamics
- TurbineGovernorDynamics
- MechanicalLoadDynamics
range: SynchronousMachineDynamics
required: false
enabled:
name: enabled
description: "Function block used indicator.\r\ntrue = use of function block is\
\ enabled\r\nfalse = use of function block is disabled."
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:DynamicsFunctionBlock.enabled
multivalued: false
alias: enabled
owner: GovHydroR
domain_of:
- ProtectiveAction
- EndDeviceFunction
- RegulatingControl
- DynamicsFunctionBlock
range: boolean
required: false
alias_name:
name: alias_name
description: "The aliasName is free text human readable name of the object alternative\
\ to IdentifiedObject.name. It may be non unique and may not correlate to a\
\ naming hierarchy.\r\nThe attribute aliasName is retained because of backwards\
\ compatibility between CIM relases. It is however recommended to replace aliasName\
\ with the Name class as aliasName is planned for retirement at a future time.\r\
\n\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.aliasName
multivalued: false
alias: alias_name
owner: GovHydroR
domain_of:
- IdentifiedObject
range: string
required: false
description:
name: description
description: The description is a free human readable text describing or naming
the object. It may be non unique and may not correlate to a naming hierarchy.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.description
multivalued: false
alias: description
owner: GovHydroR
domain_of:
- IdentifiedObject
- NameType
- NameTypeAuthority
- DataSet
- SwitchingStepGroup
- AreaReserveSpec
range: string
required: false
m_rid:
name: m_rid
description: "Master resource identifier issued by a model authority. The mRID\
\ is unique within an exchange context. Global uniqueness is easily achieved\
\ by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is\
\ strongly recommended.\r\nFor CIMXML data files in RDF syntax conforming to\
\ IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify\
\ CIM object elements."
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.mRID
multivalued: false
alias: m_rid
owner: GovHydroR
domain_of:
- IdentifiedObject
- DataSet
range: string
required: false
diagram_objects:
name: diagram_objects
description: The diagram objects that are associated with the domain object.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.DiagramObjects
multivalued: true
alias: diagram_objects
owner: GovHydroR
domain_of:
- IdentifiedObject
range: DiagramObject
required: false
instance_set:
name: instance_set
description: Dataset containing the data objects.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.InstanceSet
multivalued: false
alias: instance_set
owner: GovHydroR
domain_of:
- IdentifiedObject
range: InstanceSet
required: true
names:
name: names
description: All names of this identified object.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.Names
multivalued: true
alias: names
owner: GovHydroR
domain_of:
- IdentifiedObject
- NameType
range: Name
required: false
properties_cimdata_object:
name: properties_cimdata_object
description: The single CIM data object in the appropriate dataset context.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.PropertiesCIMDataObject
multivalued: false
alias: properties_cimdata_object
owner: GovHydroR
domain_of:
- IdentifiedObject
range: ChangeSetMember
required: false
targeting_cimdata_object:
name: targeting_cimdata_object
description: Data objects registered.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.TargetingCIMDataObject
multivalued: true
alias: targeting_cimdata_object
owner: GovHydroR
domain_of:
- IdentifiedObject
range: ChangeSetMember
required: false
class_uri: cim:GovHydroR