Class: GovHydroDD
Double derivative hydro governor and turbine.
URI: cim:GovHydroDD
classDiagram
class GovHydroDD
TurbineGovernorDynamics <|-- GovHydroDD
GovHydroDD : alias_name
GovHydroDD : asynchronous_machine_dynamics
GovHydroDD --> AsynchronousMachineDynamics : asynchronous_machine_dynamics
GovHydroDD : aturb
GovHydroDD --> PU : aturb
GovHydroDD : bturb
GovHydroDD --> PU : bturb
GovHydroDD : db
GovHydroDD --> ActivePower : db
GovHydroDD : description
GovHydroDD : diagram_objects
GovHydroDD --> DiagramObject : diagram_objects
GovHydroDD : enabled
GovHydroDD : eps
GovHydroDD --> Frequency : eps
GovHydroDD : gmax
GovHydroDD --> PU : gmax
GovHydroDD : gmin
GovHydroDD --> PU : gmin
GovHydroDD : gv
GovHydroDD --> PU : gv
GovHydroDD : input_signal
GovHydroDD : instance_set
GovHydroDD --> InstanceSet : instance_set
GovHydroDD : k
GovHydroDD --> PU : k
GovHydroDD : kg
GovHydroDD --> PU : kg
GovHydroDD : ki
GovHydroDD --> PU : ki
GovHydroDD : m_rid
GovHydroDD : mwbase
GovHydroDD --> ActivePower : mwbase
GovHydroDD : names
GovHydroDD --> Name : names
GovHydroDD : pgv
GovHydroDD --> PU : pgv
GovHydroDD : pmax
GovHydroDD --> PU : pmax
GovHydroDD : pmin
GovHydroDD --> PU : pmin
GovHydroDD : properties_cimdata_object
GovHydroDD --> ChangeSetMember : properties_cimdata_object
GovHydroDD : r
GovHydroDD --> PU : r
GovHydroDD : synchronous_machine_dynamics
GovHydroDD --> SynchronousMachineDynamics : synchronous_machine_dynamics
GovHydroDD : targeting_cimdata_object
GovHydroDD --> ChangeSetMember : targeting_cimdata_object
GovHydroDD : td
GovHydroDD --> Seconds : td
GovHydroDD : tf
GovHydroDD --> Seconds : tf
GovHydroDD : tp
GovHydroDD --> Seconds : tp
GovHydroDD : tt
GovHydroDD --> Seconds : tt
GovHydroDD : tturb
GovHydroDD --> Seconds : tturb
GovHydroDD : turbine_load_controller_dynamics
GovHydroDD --> TurbineLoadControllerDynamics : turbine_load_controller_dynamics
GovHydroDD : velcl
GovHydroDD : velop
Inheritance
Slots
| Name | Cardinality and Range | Description | Inheritance |
|---|---|---|---|
| aturb | 0..1 PU |
Turbine numerator multiplier (Aturb) (see parameter detail 3) | direct |
| bturb | 0..1 PU |
Turbine denominator multiplier (Bturb) (see parameter detail 3) | direct |
| db | 0..1 ActivePower |
Unintentional dead-band (db2) | direct |
| eps | 0..1 Frequency |
Intentional db hysteresis (eps) | direct |
| gmax | 0..1 PU |
Maximum gate opening (Gmax) (> GovHydroDD | direct |
| gmin | 0..1 PU |
Minimum gate opening (Gmin) (< GovHydroDD | direct |
| gv | 0..1 PU |
Nonlinear gain point 6, PU gv (Gv6) | direct |
| input_signal | 0..1 Boolean |
Input signal switch (Flag) | direct |
| k | 0..1 PU |
Double derivative gain (K2) | direct |
| kg | 0..1 PU |
Gate servo gain (Kg) | direct |
| ki | 0..1 PU |
Integral gain (Ki) | direct |
| mwbase | 0..1 ActivePower |
Base for power values (MWbase) (>0) | direct |
| pgv | 0..1 PU |
Nonlinear gain point 6, PU power (Pgv6) | direct |
| pmax | 0..1 PU |
Maximum gate opening, PU of MWbase (Pmax) (> GovHydroDD | direct |
| pmin | 0..1 PU |
Minimum gate opening, PU of MWbase (Pmin) (> GovHydroDD | direct |
| r | 0..1 PU |
Steady state droop (R) | direct |
| td | 0..1 Seconds |
Input filter time constant (Td) (>= 0) | direct |
| tf | 0..1 Seconds |
Washout time constant (Tf) (>= 0) | direct |
| tp | 0..1 Seconds |
Gate servo time constant (Tp) (>= 0) | direct |
| tt | 0..1 Seconds |
Power feedback time constant (Tt) (>= 0) | direct |
| tturb | 0..1 Seconds |
Turbine time constant (Tturb) (>= 0) | direct |
| velcl | 0..1 Float |
Maximum gate closing velocity (Velcl) | direct |
| velop | 0..1 Float |
Maximum gate opening velocity (Velop) | direct |
| asynchronous_machine_dynamics | 0..1 AsynchronousMachineDynamics |
Asynchronous machine model with which this turbine-governor model is associat... | TurbineGovernorDynamics |
| turbine_load_controller_dynamics | 0..1 TurbineLoadControllerDynamics |
Turbine load controller providing input to this turbine-governor | TurbineGovernorDynamics |
| synchronous_machine_dynamics | 0..1 SynchronousMachineDynamics |
Synchronous machine model with which this turbine-governor model is associate... | TurbineGovernorDynamics |
| enabled | 0..1 Boolean |
Function block used indicator | DynamicsFunctionBlock |
| alias_name | 0..1 String |
The aliasName is free text human readable name of the object alternative to I... | IdentifiedObject |
| description | 0..1 String |
The description is a free human readable text describing or naming the object | IdentifiedObject |
| m_rid | 0..1 String |
Master resource identifier issued by a model authority | IdentifiedObject |
| diagram_objects | 0..* DiagramObject |
The diagram objects that are associated with the domain object | IdentifiedObject |
| instance_set | 1..1 InstanceSet |
Dataset containing the data objects | IdentifiedObject |
| names | 0..* Name |
All names of this identified object | IdentifiedObject |
| properties_cimdata_object | 0..1 ChangeSetMember |
The single CIM data object in the appropriate dataset context | IdentifiedObject |
| targeting_cimdata_object | 0..* ChangeSetMember |
Data objects registered | IdentifiedObject |
Identifier and Mapping Information
Schema Source
- from schema: https://cim.ucaiug.io/ns#TC57CIM
Mappings
| Mapping Type | Mapped Value |
|---|---|
| self | cim:GovHydroDD |
| native | cim:GovHydroDD |
LinkML Source
Direct
name: GovHydroDD
description: Double derivative hydro governor and turbine.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
is_a: TurbineGovernorDynamics
attributes:
aturb:
name: aturb
description: Turbine numerator multiplier (<i>Aturb</i>) (see parameter detail
3). Typical value = -1.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroDD.aturb
multivalued: false
domain_of:
- GovHydroIEEE2
- GovHydro2
- GovHydroDD
- GovHydroPID
range: PU
required: false
bturb:
name: bturb
description: Turbine denominator multiplier (<i>Bturb</i>) (see parameter detail
3). Typical value = 0,5.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroDD.bturb
multivalued: false
domain_of:
- GovHydroIEEE2
- GovHydro2
- GovHydroDD
- GovHydroPID
range: PU
required: false
db:
name: db
description: Unintentional dead-band (<i>db2</i>). Unit = MW. Typical value
= 0.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroDD.db2
multivalued: false
domain_of:
- GovCT1
- GovCT2
- GovGAST1
- GovHydro2
- GovHydro3
- GovHydro4
- GovHydroDD
- GovHydroFrancis
- GovHydroPelton
- GovHydroPID
- GovHydroR
- GovHydroWEH
- GovSteam1
- GovSteamEU
- TurbLCFB1
range: ActivePower
required: false
eps:
name: eps
description: Intentional db hysteresis (<i>eps</i>). Unit = Hz. Typical value
= 0.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroDD.eps
multivalued: false
domain_of:
- GovGAST1
- GovHydro2
- GovHydro3
- GovHydro4
- GovHydroDD
- GovHydroPID
- GovHydroR
- GovSteam1
range: Frequency
required: false
gmax:
name: gmax
description: Maximum gate opening (<i>Gmax</i>) (> GovHydroDD.gmin). Typical
value = 0.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroDD.gmax
multivalued: false
domain_of:
- GovHydro1
- GovHydro4
- GovHydroDD
- GovHydroPID2
- GovHydroR
- GovHydroWEH
range: PU
required: false
gmin:
name: gmin
description: Minimum gate opening (<i>Gmin</i>) (< GovHydroDD.gmax). Typical
value = 0.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroDD.gmin
multivalued: false
domain_of:
- GovHydro1
- GovHydro4
- GovHydroDD
- GovHydroPID2
- GovHydroR
- GovHydroWEH
range: PU
required: false
gv:
name: gv
description: Nonlinear gain point 6, PU gv (<i>Gv6</i>). Typical value = 0.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroDD.gv6
multivalued: false
domain_of:
- GovHydroIEEE2
- GovGAST1
- GovHydro2
- GovHydro3
- GovHydro4
- GovHydroDD
- GovHydroPID
- GovHydroR
- GovHydroWEH
- GovHydroWPID
- GovSteam1
- GovSteamFV3
range: PU
required: false
input_signal:
name: input_signal
description: "Input signal switch (<i>Flag</i>). \r\ntrue = <i>Pe</i> input is\
\ used\r\nfalse = feedback is received from <i>CV</i>.\r\n<i>Flag</i> is normally\
\ dependent on <i>Tt</i>. If <i>Tt</i> is zero, <i>Flag</i> is set to false.\
\ If <i>Tt</i> is not zero, <i>Flag</i> is set to true. \r\nTypical value =\
\ true."
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GovHydroDD.inputSignal
multivalued: false
domain_of:
- GovHydroDD
- GovHydroPID
- GovHydroR
range: boolean
required: false
k:
name: k
description: Double derivative gain (<i>K2</i>). Typical value = 0,2.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroDD.k2
multivalued: false
domain_of:
- GovHydroIEEE0
- GovSteamIEEE1
- GovGAST2
- GovGASTWD
- GovHydro3
- GovHydroDD
- GovSteam1
- GovSteam2
- GovSteamBB
- GovSteamFV2
- GovSteamFV3
- GovSteamSGO
- ExcANS
- ExcAVR7
- ExcBBC
- ExcELIN2
- ExcSCRX
- ExcSEXS
- ExcSK
- ExcST6B
- UnderexcLimIEEE2
- UnderexcLimX1
- Pss2ST
- PssPTIST1
- PssPTIST3
- PssSH
- PssSK
- PssSTAB2A
- PssWECC
range: PU
required: false
kg:
name: kg
description: Gate servo gain (<i>Kg</i>). Typical value = 3.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroDD.kg
multivalued: false
domain_of:
- GovHydro3
- GovHydroDD
- GovHydroFrancis
- GovHydroPelton
- GovHydroPID
- GovHydroR
- GovSteamBB
- ExcIEEEST3A
- ExcIEEEST4B
- ExcIEEEST6B
- ExcST3A
- ExcST4B
- ExcST6B
range: PU
required: false
ki:
name: ki
description: Integral gain (<i>Ki</i>). Typical value = 1.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroDD.ki
multivalued: false
domain_of:
- GovGASTWD
- GovHydro3
- GovHydroDD
- GovHydroPID
- GovHydroPID2
- GovHydroR
- GovHydroWEH
- GovHydroWPID
- TurbLCFB1
- ExcIEEEDC4B
- ExcIEEEST2A
- ExcIEEEST3A
- ExcIEEEST4B
- ExcDC3A1
- ExcHU
- ExcPIC
- ExcRQB
- ExcST2A
- ExcST3A
- ExcST4B
- PssIEEE4B
- PssRQB
- PFVArType2IEEEPFController
- PFVArType2IEEEVArController
- PFVArType2Common1
range: PU
required: false
mwbase:
name: mwbase
description: Base for power values (<i>MWbase</i>) (>0). Unit = MW.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroDD.mwbase
multivalued: false
domain_of:
- GovHydroIEEE0
- GovHydroIEEE2
- GovSteamIEEE1
- GovCT1
- GovCT2
- GovGAST
- GovGAST1
- GovGAST2
- GovGASTWD
- GovHydro1
- GovHydro2
- GovHydro3
- GovHydro4
- GovHydroDD
- GovHydroPID
- GovHydroPID2
- GovHydroR
- GovHydroWEH
- GovHydroWPID
- GovSteam0
- GovSteam1
- GovSteamCC
- GovSteamEU
- GovSteamFV2
- GovSteamFV3
- GovSteamSGO
- TurbLCFB1
range: ActivePower
required: false
pgv:
name: pgv
description: Nonlinear gain point 6, PU power (<i>Pgv6</i>). Typical value =
0.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroDD.pgv6
multivalued: false
domain_of:
- GovHydroIEEE2
- GovGAST1
- GovHydro2
- GovHydro3
- GovHydro4
- GovHydroDD
- GovHydroPID
- GovHydroR
- GovHydroWPID
- GovSteam1
- GovSteamFV3
range: PU
required: false
pmax:
name: pmax
description: Maximum gate opening, PU of <i>MWbase</i> (<i>Pmax</i>) (> GovHydroDD.pmin). Typical
value = 1.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroDD.pmax
multivalued: false
domain_of:
- GovHydroIEEE0
- GovHydroIEEE2
- GovSteamIEEE1
- GovHydro2
- GovHydro3
- GovHydroDD
- GovHydroPID
- GovHydroR
- GovHydroWPID
- GovSteam1
- GovSteam2
- GovSteamBB
- GovSteamEU
- GovSteamFV3
- GovSteamSGO
range: PU
required: false
pmin:
name: pmin
description: Minimum gate opening, PU of <i>MWbase</i> (<i>Pmin</i>) (> GovHydroDD.pmax). Typical
value = 0.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroDD.pmin
multivalued: false
domain_of:
- GovHydroIEEE0
- GovHydroIEEE2
- GovSteamIEEE1
- GovHydro2
- GovHydro3
- GovHydroDD
- GovHydroPID
- GovHydroR
- GovHydroWPID
- GovSteam1
- GovSteam2
- GovSteamBB
- GovSteamFV3
- GovSteamSGO
- Pss1
- Pss5
- PssPTIST3
- WindPitchContPowerIEC
range: PU
required: false
r:
name: r
description: Steady state droop (<i>R</i>). Typical value = 0,05.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroDD.r
multivalued: false
domain_of:
- MutualCoupling
- TransformerMeshImpedance
- TransformerEndInfo
- PowerTransformerEnd
- ACLineSegment
- SynchronousMachine
- EquivalentInjection
- PowerElectronicsConnection
- SeriesCompensator
- TransformerStarImpedance
- TapChangerTablePoint
- PerLengthSequenceImpedance
- PhaseImpedanceData
- EarthFaultCompensator
- EnergySource
- EquivalentBranch
- DCGround
- GovCT1
- GovCT2
- GovGAST
- GovGAST1
- GovHydroDD
- GovHydroPID
- GovHydroR
- GovSteam0
- GovSteamFV2
- ExcNI
- UnderexcLimX2
range: PU
required: false
td:
name: td
description: Input filter time constant (<i>Td</i>) (>= 0). If = 0, block
is bypassed. Typical value = 0.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroDD.td
multivalued: false
domain_of:
- GovGAST3
- GovGASTWD
- GovHydro3
- GovHydroDD
- GovHydroFrancis
- GovHydroPID
- GovHydroR
- GovHydroWEH
- GovSteamBB
- ExcIEEEDC4B
- PssSB4
- PssSH
- DiscExcContIEEEDEC1A
- DiscExcContIEEEDEC2A
range: Seconds
required: false
tf:
name: tf
description: Washout time constant (<i>Tf</i>) (>= 0). Typical value = 0,1.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroDD.tf
multivalued: false
domain_of:
- GovGAST2
- GovGASTWD
- GovHydro1
- GovHydro3
- GovHydroDD
- GovHydroPID
- GovSteamEU
- GovSteamFV4
- ExcIEEEAC1A
- ExcIEEEAC2A
- ExcIEEEAC3A
- ExcIEEEAC5A
- ExcIEEEAC7B
- ExcIEEEDC1A
- ExcIEEEDC2A
- ExcIEEEDC4B
- ExcIEEEST1A
- ExcIEEEST2A
- ExcIEEEST7B
- ExcAC1A
- ExcAC2A
- ExcAC3A
- ExcAC5A
- ExcAVR1
- ExcAVR2
- ExcDC1A
- ExcDC2A
- ExcDC3A1
- ExcNI
- ExcOEX3T
- ExcPIC
- ExcREXS
- ExcRQB
- ExcST1A
- ExcST2A
- ExcST7B
- UnderexcLimX1
- UnderexcLimX2
- PssPTIST1
- PssPTIST3
range: Seconds
required: false
tp:
name: tp
description: Gate servo time constant (<i>Tp</i>) (>= 0). If = 0, block is
bypassed. Typical value = 0,35.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroDD.tp
multivalued: false
domain_of:
- GovHydroIEEE2
- GovHydro2
- GovHydro3
- GovHydro4
- GovHydroDD
- GovHydroPID
- GovHydroR
- GovHydroWEH
- GovSteamEU
- ExcREXS
- ExcSK
- PssPTIST1
- PssPTIST3
- LoadGenericNonLinear
range: Seconds
required: false
tt:
name: tt
description: Power feedback time constant (<i>Tt</i>) (>= 0). If = 0, block
is bypassed. Typical value = 0,02.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroDD.tt
multivalued: false
domain_of:
- GovGAST2
- GovGAST3
- GovGASTWD
- GovHydro3
- GovHydroDD
- GovHydroPID
- GovHydroR
- GovSteamFV2
- PssSB4
range: Seconds
required: false
tturb:
name: tturb
description: Turbine time constant (<i>Tturb</i>) (>= 0). See parameter detail
3. Typical value = 0,8.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GovHydroDD.tturb
multivalued: false
domain_of:
- GovHydroDD
- GovHydroPID
range: Seconds
required: false
velcl:
name: velcl
description: Maximum gate closing velocity (<i>Velcl</i>). Unit = PU / s. Typical
value = -0,14.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroDD.velcl
multivalued: false
domain_of:
- GovHydro3
- GovHydroDD
- GovHydroPID
- GovHydroR
range: float
required: false
velop:
name: velop
description: Maximum gate opening velocity (<i>Velop</i>). Unit = PU / s. Typical
value = 0,09.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroDD.velop
multivalued: false
domain_of:
- GovHydro3
- GovHydroDD
- GovHydroPID
- GovHydroR
range: float
required: false
class_uri: cim:GovHydroDD
Induced
name: GovHydroDD
description: Double derivative hydro governor and turbine.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
is_a: TurbineGovernorDynamics
attributes:
aturb:
name: aturb
description: Turbine numerator multiplier (<i>Aturb</i>) (see parameter detail
3). Typical value = -1.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroDD.aturb
multivalued: false
alias: aturb
owner: GovHydroDD
domain_of:
- GovHydroIEEE2
- GovHydro2
- GovHydroDD
- GovHydroPID
range: PU
required: false
bturb:
name: bturb
description: Turbine denominator multiplier (<i>Bturb</i>) (see parameter detail
3). Typical value = 0,5.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroDD.bturb
multivalued: false
alias: bturb
owner: GovHydroDD
domain_of:
- GovHydroIEEE2
- GovHydro2
- GovHydroDD
- GovHydroPID
range: PU
required: false
db:
name: db
description: Unintentional dead-band (<i>db2</i>). Unit = MW. Typical value
= 0.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroDD.db2
multivalued: false
alias: db
owner: GovHydroDD
domain_of:
- GovCT1
- GovCT2
- GovGAST1
- GovHydro2
- GovHydro3
- GovHydro4
- GovHydroDD
- GovHydroFrancis
- GovHydroPelton
- GovHydroPID
- GovHydroR
- GovHydroWEH
- GovSteam1
- GovSteamEU
- TurbLCFB1
range: ActivePower
required: false
eps:
name: eps
description: Intentional db hysteresis (<i>eps</i>). Unit = Hz. Typical value
= 0.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroDD.eps
multivalued: false
alias: eps
owner: GovHydroDD
domain_of:
- GovGAST1
- GovHydro2
- GovHydro3
- GovHydro4
- GovHydroDD
- GovHydroPID
- GovHydroR
- GovSteam1
range: Frequency
required: false
gmax:
name: gmax
description: Maximum gate opening (<i>Gmax</i>) (> GovHydroDD.gmin). Typical
value = 0.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroDD.gmax
multivalued: false
alias: gmax
owner: GovHydroDD
domain_of:
- GovHydro1
- GovHydro4
- GovHydroDD
- GovHydroPID2
- GovHydroR
- GovHydroWEH
range: PU
required: false
gmin:
name: gmin
description: Minimum gate opening (<i>Gmin</i>) (< GovHydroDD.gmax). Typical
value = 0.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroDD.gmin
multivalued: false
alias: gmin
owner: GovHydroDD
domain_of:
- GovHydro1
- GovHydro4
- GovHydroDD
- GovHydroPID2
- GovHydroR
- GovHydroWEH
range: PU
required: false
gv:
name: gv
description: Nonlinear gain point 6, PU gv (<i>Gv6</i>). Typical value = 0.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroDD.gv6
multivalued: false
alias: gv
owner: GovHydroDD
domain_of:
- GovHydroIEEE2
- GovGAST1
- GovHydro2
- GovHydro3
- GovHydro4
- GovHydroDD
- GovHydroPID
- GovHydroR
- GovHydroWEH
- GovHydroWPID
- GovSteam1
- GovSteamFV3
range: PU
required: false
input_signal:
name: input_signal
description: "Input signal switch (<i>Flag</i>). \r\ntrue = <i>Pe</i> input is\
\ used\r\nfalse = feedback is received from <i>CV</i>.\r\n<i>Flag</i> is normally\
\ dependent on <i>Tt</i>. If <i>Tt</i> is zero, <i>Flag</i> is set to false.\
\ If <i>Tt</i> is not zero, <i>Flag</i> is set to true. \r\nTypical value =\
\ true."
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GovHydroDD.inputSignal
multivalued: false
alias: input_signal
owner: GovHydroDD
domain_of:
- GovHydroDD
- GovHydroPID
- GovHydroR
range: boolean
required: false
k:
name: k
description: Double derivative gain (<i>K2</i>). Typical value = 0,2.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroDD.k2
multivalued: false
alias: k
owner: GovHydroDD
domain_of:
- GovHydroIEEE0
- GovSteamIEEE1
- GovGAST2
- GovGASTWD
- GovHydro3
- GovHydroDD
- GovSteam1
- GovSteam2
- GovSteamBB
- GovSteamFV2
- GovSteamFV3
- GovSteamSGO
- ExcANS
- ExcAVR7
- ExcBBC
- ExcELIN2
- ExcSCRX
- ExcSEXS
- ExcSK
- ExcST6B
- UnderexcLimIEEE2
- UnderexcLimX1
- Pss2ST
- PssPTIST1
- PssPTIST3
- PssSH
- PssSK
- PssSTAB2A
- PssWECC
range: PU
required: false
kg:
name: kg
description: Gate servo gain (<i>Kg</i>). Typical value = 3.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroDD.kg
multivalued: false
alias: kg
owner: GovHydroDD
domain_of:
- GovHydro3
- GovHydroDD
- GovHydroFrancis
- GovHydroPelton
- GovHydroPID
- GovHydroR
- GovSteamBB
- ExcIEEEST3A
- ExcIEEEST4B
- ExcIEEEST6B
- ExcST3A
- ExcST4B
- ExcST6B
range: PU
required: false
ki:
name: ki
description: Integral gain (<i>Ki</i>). Typical value = 1.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroDD.ki
multivalued: false
alias: ki
owner: GovHydroDD
domain_of:
- GovGASTWD
- GovHydro3
- GovHydroDD
- GovHydroPID
- GovHydroPID2
- GovHydroR
- GovHydroWEH
- GovHydroWPID
- TurbLCFB1
- ExcIEEEDC4B
- ExcIEEEST2A
- ExcIEEEST3A
- ExcIEEEST4B
- ExcDC3A1
- ExcHU
- ExcPIC
- ExcRQB
- ExcST2A
- ExcST3A
- ExcST4B
- PssIEEE4B
- PssRQB
- PFVArType2IEEEPFController
- PFVArType2IEEEVArController
- PFVArType2Common1
range: PU
required: false
mwbase:
name: mwbase
description: Base for power values (<i>MWbase</i>) (>0). Unit = MW.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroDD.mwbase
multivalued: false
alias: mwbase
owner: GovHydroDD
domain_of:
- GovHydroIEEE0
- GovHydroIEEE2
- GovSteamIEEE1
- GovCT1
- GovCT2
- GovGAST
- GovGAST1
- GovGAST2
- GovGASTWD
- GovHydro1
- GovHydro2
- GovHydro3
- GovHydro4
- GovHydroDD
- GovHydroPID
- GovHydroPID2
- GovHydroR
- GovHydroWEH
- GovHydroWPID
- GovSteam0
- GovSteam1
- GovSteamCC
- GovSteamEU
- GovSteamFV2
- GovSteamFV3
- GovSteamSGO
- TurbLCFB1
range: ActivePower
required: false
pgv:
name: pgv
description: Nonlinear gain point 6, PU power (<i>Pgv6</i>). Typical value =
0.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroDD.pgv6
multivalued: false
alias: pgv
owner: GovHydroDD
domain_of:
- GovHydroIEEE2
- GovGAST1
- GovHydro2
- GovHydro3
- GovHydro4
- GovHydroDD
- GovHydroPID
- GovHydroR
- GovHydroWPID
- GovSteam1
- GovSteamFV3
range: PU
required: false
pmax:
name: pmax
description: Maximum gate opening, PU of <i>MWbase</i> (<i>Pmax</i>) (> GovHydroDD.pmin). Typical
value = 1.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroDD.pmax
multivalued: false
alias: pmax
owner: GovHydroDD
domain_of:
- GovHydroIEEE0
- GovHydroIEEE2
- GovSteamIEEE1
- GovHydro2
- GovHydro3
- GovHydroDD
- GovHydroPID
- GovHydroR
- GovHydroWPID
- GovSteam1
- GovSteam2
- GovSteamBB
- GovSteamEU
- GovSteamFV3
- GovSteamSGO
range: PU
required: false
pmin:
name: pmin
description: Minimum gate opening, PU of <i>MWbase</i> (<i>Pmin</i>) (> GovHydroDD.pmax). Typical
value = 0.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroDD.pmin
multivalued: false
alias: pmin
owner: GovHydroDD
domain_of:
- GovHydroIEEE0
- GovHydroIEEE2
- GovSteamIEEE1
- GovHydro2
- GovHydro3
- GovHydroDD
- GovHydroPID
- GovHydroR
- GovHydroWPID
- GovSteam1
- GovSteam2
- GovSteamBB
- GovSteamFV3
- GovSteamSGO
- Pss1
- Pss5
- PssPTIST3
- WindPitchContPowerIEC
range: PU
required: false
r:
name: r
description: Steady state droop (<i>R</i>). Typical value = 0,05.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroDD.r
multivalued: false
alias: r
owner: GovHydroDD
domain_of:
- MutualCoupling
- TransformerMeshImpedance
- TransformerEndInfo
- PowerTransformerEnd
- ACLineSegment
- SynchronousMachine
- EquivalentInjection
- PowerElectronicsConnection
- SeriesCompensator
- TransformerStarImpedance
- TapChangerTablePoint
- PerLengthSequenceImpedance
- PhaseImpedanceData
- EarthFaultCompensator
- EnergySource
- EquivalentBranch
- DCGround
- GovCT1
- GovCT2
- GovGAST
- GovGAST1
- GovHydroDD
- GovHydroPID
- GovHydroR
- GovSteam0
- GovSteamFV2
- ExcNI
- UnderexcLimX2
range: PU
required: false
td:
name: td
description: Input filter time constant (<i>Td</i>) (>= 0). If = 0, block
is bypassed. Typical value = 0.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroDD.td
multivalued: false
alias: td
owner: GovHydroDD
domain_of:
- GovGAST3
- GovGASTWD
- GovHydro3
- GovHydroDD
- GovHydroFrancis
- GovHydroPID
- GovHydroR
- GovHydroWEH
- GovSteamBB
- ExcIEEEDC4B
- PssSB4
- PssSH
- DiscExcContIEEEDEC1A
- DiscExcContIEEEDEC2A
range: Seconds
required: false
tf:
name: tf
description: Washout time constant (<i>Tf</i>) (>= 0). Typical value = 0,1.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroDD.tf
multivalued: false
alias: tf
owner: GovHydroDD
domain_of:
- GovGAST2
- GovGASTWD
- GovHydro1
- GovHydro3
- GovHydroDD
- GovHydroPID
- GovSteamEU
- GovSteamFV4
- ExcIEEEAC1A
- ExcIEEEAC2A
- ExcIEEEAC3A
- ExcIEEEAC5A
- ExcIEEEAC7B
- ExcIEEEDC1A
- ExcIEEEDC2A
- ExcIEEEDC4B
- ExcIEEEST1A
- ExcIEEEST2A
- ExcIEEEST7B
- ExcAC1A
- ExcAC2A
- ExcAC3A
- ExcAC5A
- ExcAVR1
- ExcAVR2
- ExcDC1A
- ExcDC2A
- ExcDC3A1
- ExcNI
- ExcOEX3T
- ExcPIC
- ExcREXS
- ExcRQB
- ExcST1A
- ExcST2A
- ExcST7B
- UnderexcLimX1
- UnderexcLimX2
- PssPTIST1
- PssPTIST3
range: Seconds
required: false
tp:
name: tp
description: Gate servo time constant (<i>Tp</i>) (>= 0). If = 0, block is
bypassed. Typical value = 0,35.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroDD.tp
multivalued: false
alias: tp
owner: GovHydroDD
domain_of:
- GovHydroIEEE2
- GovHydro2
- GovHydro3
- GovHydro4
- GovHydroDD
- GovHydroPID
- GovHydroR
- GovHydroWEH
- GovSteamEU
- ExcREXS
- ExcSK
- PssPTIST1
- PssPTIST3
- LoadGenericNonLinear
range: Seconds
required: false
tt:
name: tt
description: Power feedback time constant (<i>Tt</i>) (>= 0). If = 0, block
is bypassed. Typical value = 0,02.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroDD.tt
multivalued: false
alias: tt
owner: GovHydroDD
domain_of:
- GovGAST2
- GovGAST3
- GovGASTWD
- GovHydro3
- GovHydroDD
- GovHydroPID
- GovHydroR
- GovSteamFV2
- PssSB4
range: Seconds
required: false
tturb:
name: tturb
description: Turbine time constant (<i>Tturb</i>) (>= 0). See parameter detail
3. Typical value = 0,8.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GovHydroDD.tturb
multivalued: false
alias: tturb
owner: GovHydroDD
domain_of:
- GovHydroDD
- GovHydroPID
range: Seconds
required: false
velcl:
name: velcl
description: Maximum gate closing velocity (<i>Velcl</i>). Unit = PU / s. Typical
value = -0,14.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroDD.velcl
multivalued: false
alias: velcl
owner: GovHydroDD
domain_of:
- GovHydro3
- GovHydroDD
- GovHydroPID
- GovHydroR
range: float
required: false
velop:
name: velop
description: Maximum gate opening velocity (<i>Velop</i>). Unit = PU / s. Typical
value = 0,09.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GovHydroDD.velop
multivalued: false
alias: velop
owner: GovHydroDD
domain_of:
- GovHydro3
- GovHydroDD
- GovHydroPID
- GovHydroR
range: float
required: false
asynchronous_machine_dynamics:
name: asynchronous_machine_dynamics
description: Asynchronous machine model with which this turbine-governor model
is associated. TurbineGovernorDynamics shall have either an association to SynchronousMachineDynamics
or to AsynchronousMachineDynamics.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:TurbineGovernorDynamics.AsynchronousMachineDynamics
multivalued: false
alias: asynchronous_machine_dynamics
owner: GovHydroDD
domain_of:
- WindTurbineType1or2Dynamics
- TurbineGovernorDynamics
- MechanicalLoadDynamics
- AsynchronousMachine
range: AsynchronousMachineDynamics
required: false
turbine_load_controller_dynamics:
name: turbine_load_controller_dynamics
description: Turbine load controller providing input to this turbine-governor.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:TurbineGovernorDynamics.TurbineLoadControllerDynamics
multivalued: false
alias: turbine_load_controller_dynamics
owner: GovHydroDD
domain_of:
- TurbineGovernorDynamics
range: TurbineLoadControllerDynamics
required: false
synchronous_machine_dynamics:
name: synchronous_machine_dynamics
description: Synchronous machine model with which this turbine-governor model
is associated. TurbineGovernorDynamics shall have either an association to SynchronousMachineDynamics
or to AsynchronousMachineDynamics.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:TurbineGovernorDynamics.SynchronousMachineDynamics
multivalued: false
alias: synchronous_machine_dynamics
owner: GovHydroDD
domain_of:
- SynchronousMachine
- GenICompensationForGenJ
- ExcitationSystemDynamics
- TurbineGovernorDynamics
- MechanicalLoadDynamics
range: SynchronousMachineDynamics
required: false
enabled:
name: enabled
description: "Function block used indicator.\r\ntrue = use of function block is\
\ enabled\r\nfalse = use of function block is disabled."
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:DynamicsFunctionBlock.enabled
multivalued: false
alias: enabled
owner: GovHydroDD
domain_of:
- ProtectiveAction
- EndDeviceFunction
- RegulatingControl
- DynamicsFunctionBlock
range: boolean
required: false
alias_name:
name: alias_name
description: "The aliasName is free text human readable name of the object alternative\
\ to IdentifiedObject.name. It may be non unique and may not correlate to a\
\ naming hierarchy.\r\nThe attribute aliasName is retained because of backwards\
\ compatibility between CIM relases. It is however recommended to replace aliasName\
\ with the Name class as aliasName is planned for retirement at a future time.\r\
\n\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.aliasName
multivalued: false
alias: alias_name
owner: GovHydroDD
domain_of:
- IdentifiedObject
range: string
required: false
description:
name: description
description: The description is a free human readable text describing or naming
the object. It may be non unique and may not correlate to a naming hierarchy.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.description
multivalued: false
alias: description
owner: GovHydroDD
domain_of:
- IdentifiedObject
- NameType
- NameTypeAuthority
- DataSet
- SwitchingStepGroup
- AreaReserveSpec
range: string
required: false
m_rid:
name: m_rid
description: "Master resource identifier issued by a model authority. The mRID\
\ is unique within an exchange context. Global uniqueness is easily achieved\
\ by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is\
\ strongly recommended.\r\nFor CIMXML data files in RDF syntax conforming to\
\ IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify\
\ CIM object elements."
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.mRID
multivalued: false
alias: m_rid
owner: GovHydroDD
domain_of:
- IdentifiedObject
- DataSet
range: string
required: false
diagram_objects:
name: diagram_objects
description: The diagram objects that are associated with the domain object.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.DiagramObjects
multivalued: true
alias: diagram_objects
owner: GovHydroDD
domain_of:
- IdentifiedObject
range: DiagramObject
required: false
instance_set:
name: instance_set
description: Dataset containing the data objects.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.InstanceSet
multivalued: false
alias: instance_set
owner: GovHydroDD
domain_of:
- IdentifiedObject
range: InstanceSet
required: true
names:
name: names
description: All names of this identified object.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.Names
multivalued: true
alias: names
owner: GovHydroDD
domain_of:
- IdentifiedObject
- NameType
range: Name
required: false
properties_cimdata_object:
name: properties_cimdata_object
description: The single CIM data object in the appropriate dataset context.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.PropertiesCIMDataObject
multivalued: false
alias: properties_cimdata_object
owner: GovHydroDD
domain_of:
- IdentifiedObject
range: ChangeSetMember
required: false
targeting_cimdata_object:
name: targeting_cimdata_object
description: Data objects registered.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.TargetingCIMDataObject
multivalued: true
alias: targeting_cimdata_object
owner: GovHydroDD
domain_of:
- IdentifiedObject
range: ChangeSetMember
required: false
class_uri: cim:GovHydroDD