Skip to content

Class: GeneratingUnitDynamicValues

_Optimal Power Flow or State Estimator Unit Data for Operator Training Simulator. This is used for RealTime, Study and Maintenance Users. _

__

URI: cim:GeneratingUnitDynamicValues

 classDiagram
    class GeneratingUnitDynamicValues
      GeneratingUnitDynamicValues : flowgate

          GeneratingUnitDynamicValues --> Flowgate : flowgate

      GeneratingUnitDynamicValues : loss_factor

      GeneratingUnitDynamicValues : m_var

      GeneratingUnitDynamicValues : maximum_mw

      GeneratingUnitDynamicValues : minimum_mw

      GeneratingUnitDynamicValues : mkt_generating_unit

          GeneratingUnitDynamicValues --> MktGeneratingUnit : mkt_generating_unit

      GeneratingUnitDynamicValues : mw

      GeneratingUnitDynamicValues : sensitivity

Slots

Name Cardinality and Range Description Inheritance
loss_factor 0..1
Float
Loss Factor
direct
maximum_mw 0..1
Float
The maximum active power generation of the unit in MW
direct
minimum_mw 0..1
Float
The minimum active power generation of the unit in MW
direct
m_var 0..1
Float
Unit reactive power generation in MVAR
direct
mw 0..1
Float
Unit active power generation in MW
direct
sensitivity 0..1
Float
Unit sencivity factor direct
mkt_generating_unit 1..1
MktGeneratingUnit
direct
flowgate 0..1
Flowgate
direct

Usages

used by used in type used
Flowgate generating_unit_dynamic_values range GeneratingUnitDynamicValues
MktGeneratingUnit generating_unit_dynamic_values range GeneratingUnitDynamicValues

Identifier and Mapping Information

Schema Source

  • from schema: https://cim.ucaiug.io/ns#TC57CIM

Mappings

Mapping Type Mapped Value
self cim:GeneratingUnitDynamicValues
native cim:GeneratingUnitDynamicValues

LinkML Source

Direct

name: GeneratingUnitDynamicValues
description: "Optimal Power Flow or State Estimator Unit Data for Operator Training\
  \ Simulator. This is used for RealTime, Study and Maintenance Users.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
attributes:
  loss_factor:
    name: loss_factor
    description: "Loss Factor\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:GeneratingUnitDynamicValues.lossFactor
    multivalued: false
    domain_of:
    - LossSensitivity
    - GeneratingUnitDynamicValues
    - MSSZone
    range: float
    required: false
  maximum_mw:
    name: maximum_mw
    description: "The maximum active power generation of the unit in MW\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GeneratingUnitDynamicValues.maximumMW
    multivalued: false
    domain_of:
    - GeneratingUnitDynamicValues
    range: float
    required: false
  minimum_mw:
    name: minimum_mw
    description: "The minimum active power generation of the unit in MW\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GeneratingUnitDynamicValues.minimumMW
    multivalued: false
    domain_of:
    - GeneratingUnitDynamicValues
    range: float
    required: false
  m_var:
    name: m_var
    description: "Unit reactive power generation in MVAR\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GeneratingUnitDynamicValues.mVAR
    multivalued: false
    domain_of:
    - GeneratingUnitDynamicValues
    range: float
    required: false
  mw:
    name: mw
    description: "Unit active power generation in MW\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GeneratingUnitDynamicValues.mw
    multivalued: false
    domain_of:
    - GeneratingUnitDynamicValues
    range: float
    required: false
  sensitivity:
    name: sensitivity
    description: "Unit sencivity factor. The distribution factors (DFAX) for the unit\r\
      \n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GeneratingUnitDynamicValues.sensitivity
    multivalued: false
    domain_of:
    - GeneratingUnitDynamicValues
    range: float
    required: false
  mkt_generating_unit:
    name: mkt_generating_unit
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GeneratingUnitDynamicValues.MktGeneratingUnit
    multivalued: false
    domain_of:
    - GeneratingUnitDynamicValues
    range: MktGeneratingUnit
    required: true
  flowgate:
    name: flowgate
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:GeneratingUnitDynamicValues.Flowgate
    multivalued: false
    domain_of:
    - FTR
    - MktLine
    - ViolationLimit
    - HostControlArea
    - RegisteredInterTie
    - SchedulingPoint
    - SecurityConstraints
    - TransmissionInterfaceRightEntitlement
    - ContractDistributionFactor
    - ConstraintResults
    - GeneratingUnitDynamicValues
    - CongestionRevenueRight
    - GenericConstraints
    - TransmissionCapacity
    - MktTerminal
    - FlowgateValue
    - FlowgateRelief
    - MktPowerTransformer
    - InterTieResults
    range: Flowgate
    required: false
class_uri: cim:GeneratingUnitDynamicValues

Induced

name: GeneratingUnitDynamicValues
description: "Optimal Power Flow or State Estimator Unit Data for Operator Training\
  \ Simulator. This is used for RealTime, Study and Maintenance Users.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
attributes:
  loss_factor:
    name: loss_factor
    description: "Loss Factor\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:GeneratingUnitDynamicValues.lossFactor
    multivalued: false
    alias: loss_factor
    owner: GeneratingUnitDynamicValues
    domain_of:
    - LossSensitivity
    - GeneratingUnitDynamicValues
    - MSSZone
    range: float
    required: false
  maximum_mw:
    name: maximum_mw
    description: "The maximum active power generation of the unit in MW\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GeneratingUnitDynamicValues.maximumMW
    multivalued: false
    alias: maximum_mw
    owner: GeneratingUnitDynamicValues
    domain_of:
    - GeneratingUnitDynamicValues
    range: float
    required: false
  minimum_mw:
    name: minimum_mw
    description: "The minimum active power generation of the unit in MW\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GeneratingUnitDynamicValues.minimumMW
    multivalued: false
    alias: minimum_mw
    owner: GeneratingUnitDynamicValues
    domain_of:
    - GeneratingUnitDynamicValues
    range: float
    required: false
  m_var:
    name: m_var
    description: "Unit reactive power generation in MVAR\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GeneratingUnitDynamicValues.mVAR
    multivalued: false
    alias: m_var
    owner: GeneratingUnitDynamicValues
    domain_of:
    - GeneratingUnitDynamicValues
    range: float
    required: false
  mw:
    name: mw
    description: "Unit active power generation in MW\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GeneratingUnitDynamicValues.mw
    multivalued: false
    alias: mw
    owner: GeneratingUnitDynamicValues
    domain_of:
    - GeneratingUnitDynamicValues
    range: float
    required: false
  sensitivity:
    name: sensitivity
    description: "Unit sencivity factor. The distribution factors (DFAX) for the unit\r\
      \n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GeneratingUnitDynamicValues.sensitivity
    multivalued: false
    alias: sensitivity
    owner: GeneratingUnitDynamicValues
    domain_of:
    - GeneratingUnitDynamicValues
    range: float
    required: false
  mkt_generating_unit:
    name: mkt_generating_unit
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:GeneratingUnitDynamicValues.MktGeneratingUnit
    multivalued: false
    alias: mkt_generating_unit
    owner: GeneratingUnitDynamicValues
    domain_of:
    - GeneratingUnitDynamicValues
    range: MktGeneratingUnit
    required: true
  flowgate:
    name: flowgate
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:GeneratingUnitDynamicValues.Flowgate
    multivalued: false
    alias: flowgate
    owner: GeneratingUnitDynamicValues
    domain_of:
    - FTR
    - MktLine
    - ViolationLimit
    - HostControlArea
    - RegisteredInterTie
    - SchedulingPoint
    - SecurityConstraints
    - TransmissionInterfaceRightEntitlement
    - ContractDistributionFactor
    - ConstraintResults
    - GeneratingUnitDynamicValues
    - CongestionRevenueRight
    - GenericConstraints
    - TransmissionCapacity
    - MktTerminal
    - FlowgateValue
    - FlowgateRelief
    - MktPowerTransformer
    - InterTieResults
    range: Flowgate
    required: false
class_uri: cim:GeneratingUnitDynamicValues