Class: GeneratingUnit
A single or set of synchronous machines for converting mechanical power into alternating-current power. For example, individual machines within a set may be defined for scheduling purposes while a single control signal is derived for the set. In this case there would be a GeneratingUnit for each member of the set and an additional GeneratingUnit corresponding to the set.
URI: cim:GeneratingUnit
classDiagram
class GeneratingUnit
Equipment <|-- GeneratingUnit
GeneratingUnit <|-- ThermalGeneratingUnit
GeneratingUnit <|-- HydroGeneratingUnit
GeneratingUnit <|-- MktGeneratingUnit
GeneratingUnit <|-- NuclearGeneratingUnit
GeneratingUnit <|-- WindGeneratingUnit
GeneratingUnit <|-- SolarGeneratingUnit
GeneratingUnit : additional_equipment_container
GeneratingUnit --> EquipmentContainer : additional_equipment_container
GeneratingUnit : aggregate
GeneratingUnit : alias_name
GeneratingUnit : alloc_spin_res_p
GeneratingUnit --> ActivePower : alloc_spin_res_p
GeneratingUnit : asset_datasheet
GeneratingUnit --> AssetInfo : asset_datasheet
GeneratingUnit : assets
GeneratingUnit --> Asset : assets
GeneratingUnit : auto_cntrl_margin_p
GeneratingUnit --> ActivePower : auto_cntrl_margin_p
GeneratingUnit : base_p
GeneratingUnit --> ActivePower : base_p
GeneratingUnit : clearances
GeneratingUnit --> ClearanceDocument : clearances
GeneratingUnit : configuration_event
GeneratingUnit --> ConfigurationEvent : configuration_event
GeneratingUnit : contingency_equipment
GeneratingUnit --> ContingencyEquipment : contingency_equipment
GeneratingUnit : control_area_generating_unit
GeneratingUnit --> ControlAreaGeneratingUnit : control_area_generating_unit
GeneratingUnit : control_deadband
GeneratingUnit --> ActivePower : control_deadband
GeneratingUnit : control_pulse_high
GeneratingUnit --> Seconds : control_pulse_high
GeneratingUnit : control_pulse_low
GeneratingUnit --> Seconds : control_pulse_low
GeneratingUnit : control_response_rate
GeneratingUnit --> ActivePowerChangeRate : control_response_rate
GeneratingUnit : controls
GeneratingUnit --> Control : controls
GeneratingUnit : description
GeneratingUnit : diagram_objects
GeneratingUnit --> DiagramObject : diagram_objects
GeneratingUnit : efficiency
GeneratingUnit --> PerCent : efficiency
GeneratingUnit : eqiupment_limit_series_component
GeneratingUnit --> EquipmentLimitSeriesComponent : eqiupment_limit_series_component
GeneratingUnit : equipment_container
GeneratingUnit --> EquipmentContainer : equipment_container
GeneratingUnit : equipment_unavailability_schedule
GeneratingUnit --> EquipmentUnavailabilitySchedule : equipment_unavailability_schedule
GeneratingUnit : faults
GeneratingUnit --> Fault : faults
GeneratingUnit : gen_control_mode
GeneratingUnit --> GeneratorControlMode : gen_control_mode
GeneratingUnit : gen_control_source
GeneratingUnit --> GeneratorControlSource : gen_control_source
GeneratingUnit : gen_unit_op_cost_curves
GeneratingUnit --> GenUnitOpCostCurve : gen_unit_op_cost_curves
GeneratingUnit : gen_unit_op_schedule
GeneratingUnit --> GenUnitOpSchedule : gen_unit_op_schedule
GeneratingUnit : generic_action
GeneratingUnit --> GenericAction : generic_action
GeneratingUnit : governor_mpl
GeneratingUnit --> PU : governor_mpl
GeneratingUnit : governor_scd
GeneratingUnit --> PerCent : governor_scd
GeneratingUnit : gross_to_net_active_power_curves
GeneratingUnit --> GrossToNetActivePowerCurve : gross_to_net_active_power_curves
GeneratingUnit : high_control_limit
GeneratingUnit --> ActivePower : high_control_limit
GeneratingUnit : in_service
GeneratingUnit : initial_p
GeneratingUnit --> ActivePower : initial_p
GeneratingUnit : instance_set
GeneratingUnit --> InstanceSet : instance_set
GeneratingUnit : limit_dependency_model
GeneratingUnit --> LimitDependency : limit_dependency_model
GeneratingUnit : location
GeneratingUnit --> Location : location
GeneratingUnit : long_pf
GeneratingUnit : low_control_limit
GeneratingUnit --> ActivePower : low_control_limit
GeneratingUnit : lower_ramp_rate
GeneratingUnit --> ActivePowerChangeRate : lower_ramp_rate
GeneratingUnit : m_rid
GeneratingUnit : max_economic_p
GeneratingUnit --> ActivePower : max_economic_p
GeneratingUnit : max_operating_p
GeneratingUnit --> ActivePower : max_operating_p
GeneratingUnit : maximum_allowable_spinning_reserve
GeneratingUnit --> ActivePower : maximum_allowable_spinning_reserve
GeneratingUnit : measurements
GeneratingUnit --> Measurement : measurements
GeneratingUnit : min_economic_p
GeneratingUnit --> ActivePower : min_economic_p
GeneratingUnit : min_operating_p
GeneratingUnit --> ActivePower : min_operating_p
GeneratingUnit : minimum_off_time
GeneratingUnit --> Seconds : minimum_off_time
GeneratingUnit : model_detail
GeneratingUnit --> Classification : model_detail
GeneratingUnit : names
GeneratingUnit --> Name : names
GeneratingUnit : network_analysis_enabled
GeneratingUnit : nominal_p
GeneratingUnit --> ActivePower : nominal_p
GeneratingUnit : normal_pf
GeneratingUnit : normally_in_service
GeneratingUnit : operating_share
GeneratingUnit --> OperatingShare : operating_share
GeneratingUnit : operational_limit_set
GeneratingUnit --> OperationalLimitSet : operational_limit_set
GeneratingUnit : operational_restrictions
GeneratingUnit --> OperationalRestriction : operational_restrictions
GeneratingUnit : operational_tags
GeneratingUnit --> OperationalTag : operational_tags
GeneratingUnit : outages
GeneratingUnit --> Outage : outages
GeneratingUnit : penalty_factor
GeneratingUnit : pin_equipment
GeneratingUnit --> PinEquipment : pin_equipment
GeneratingUnit : properties_cimdata_object
GeneratingUnit --> ChangeSetMember : properties_cimdata_object
GeneratingUnit : protective_action_equipment
GeneratingUnit --> ProtectiveActionEquipment : protective_action_equipment
GeneratingUnit : psrevents
GeneratingUnit --> PSREvent : psrevents
GeneratingUnit : psrtype
GeneratingUnit --> PSRType : psrtype
GeneratingUnit : raise_ramp_rate
GeneratingUnit --> ActivePowerChangeRate : raise_ramp_rate
GeneratingUnit : rated_gross_max_p
GeneratingUnit --> ActivePower : rated_gross_max_p
GeneratingUnit : rated_gross_min_p
GeneratingUnit --> ActivePower : rated_gross_min_p
GeneratingUnit : rated_net_max_p
GeneratingUnit --> ActivePower : rated_net_max_p
GeneratingUnit : reporting_group
GeneratingUnit --> ReportingGroup : reporting_group
GeneratingUnit : rotating_machine
GeneratingUnit --> RotatingMachine : rotating_machine
GeneratingUnit : short_pf
GeneratingUnit : startup_cost
GeneratingUnit --> Money : startup_cost
GeneratingUnit : startup_time
GeneratingUnit --> Seconds : startup_time
GeneratingUnit : targeting_cimdata_object
GeneratingUnit --> ChangeSetMember : targeting_cimdata_object
GeneratingUnit : tie_line_pf
GeneratingUnit : total_efficiency
GeneratingUnit --> PerCent : total_efficiency
GeneratingUnit : usage_points
GeneratingUnit --> UsagePoint : usage_points
GeneratingUnit : variable_cost
GeneratingUnit --> Money : variable_cost
GeneratingUnit : verification_action
GeneratingUnit --> VerificationAction : verification_action
GeneratingUnit : weather_station
GeneratingUnit --> WeatherStation : weather_station
Inheritance
Slots
| Name | Cardinality and Range | Description | Inheritance |
|---|---|---|---|
| alloc_spin_res_p | 0..1 ActivePower |
The planned unused capacity (spinning reserve) which can be used to support e... | direct |
| auto_cntrl_margin_p | 0..1 ActivePower |
The planned unused capacity which can be used to support automatic control ov... | direct |
| base_p | 0..1 ActivePower |
For dispatchable units, this value represents the economic active power basep... | direct |
| control_deadband | 0..1 ActivePower |
Unit control error deadband | direct |
| control_pulse_high | 0..1 Seconds |
Pulse high limit which is the largest control pulse that the unit can respond... | direct |
| control_pulse_low | 0..1 Seconds |
Pulse low limit which is the smallest control pulse that the unit can respond... | direct |
| control_response_rate | 0..1 ActivePowerChangeRate |
Unit response rate which specifies the active power change for a control puls... | direct |
| efficiency | 0..1 PerCent |
The efficiency of the unit in converting mechanical energy, from the prime mo... | direct |
| gen_control_mode | 0..1 GeneratorControlMode |
The unit control mode | direct |
| gen_control_source | 0..1 GeneratorControlSource |
The source of controls for a generating unit | direct |
| governor_mpl | 0..1 PU |
Governor motor position limit | direct |
| governor_scd | 0..1 PerCent |
Governor Speed Changer Droop | direct |
| high_control_limit | 0..1 ActivePower |
High limit for secondary (AGC) control | direct |
| initial_p | 0..1 ActivePower |
Default initial active power which is used to store a powerflow result for t... | direct |
| long_pf | 0..1 Float |
Generating unit long term economic participation factor | direct |
| low_control_limit | 0..1 ActivePower |
Low limit for secondary (AGC) control | direct |
| lower_ramp_rate | 0..1 ActivePowerChangeRate |
The normal maximum rate the generating unit active power output can be lowere... | direct |
| max_economic_p | 0..1 ActivePower |
Maximum high economic active power limit, that should not exceed the maximum ... | direct |
| maximum_allowable_spinning_reserve | 0..1 ActivePower |
Maximum allowable spinning reserve | direct |
| max_operating_p | 0..1 ActivePower |
This is the maximum operating active power limit the dispatcher can enter for... | direct |
| min_economic_p | 0..1 ActivePower |
Low economic active power limit that shall be greater than or equal to the mi... | direct |
| minimum_off_time | 0..1 Seconds |
Minimum time interval between unit shutdown and startup | direct |
| min_operating_p | 0..1 ActivePower |
This is the minimum operating active power limit the dispatcher can enter for... | direct |
| model_detail | 0..1 Classification |
Detail level of the generator model data | direct |
| nominal_p | 0..1 ActivePower |
The nominal power of the generating unit | direct |
| normal_pf | 0..1 Float |
Generating unit economic participation factor | direct |
| penalty_factor | 0..1 Float |
Defined as: 1 / ( 1 - Incremental Transmission Loss); with the Incremental Tr... | direct |
| raise_ramp_rate | 0..1 ActivePowerChangeRate |
The normal maximum rate the generating unit active power output can be raised... | direct |
| rated_gross_max_p | 0..1 ActivePower |
The unit's gross rated maximum capacity (book value) | direct |
| rated_gross_min_p | 0..1 ActivePower |
The gross rated minimum generation level which the unit can safely operate at... | direct |
| rated_net_max_p | 0..1 ActivePower |
The net rated maximum capacity determined by subtracting the auxiliary power ... | direct |
| short_pf | 0..1 Float |
Generating unit short term economic participation factor | direct |
| startup_cost | 0..1 Money |
The initial startup cost incurred for each start of the GeneratingUnit | direct |
| startup_time | 0..1 Seconds |
Time it takes to get the unit on-line, from the time that the prime mover mec... | direct |
| tie_line_pf | 0..1 Float |
Generating unit economic participation factor | direct |
| total_efficiency | 0..1 PerCent |
The efficiency of the unit in converting the fuel into electrical energy | direct |
| variable_cost | 0..1 Money |
The variable cost component of production per unit of ActivePower | direct |
| rotating_machine | 0..* RotatingMachine |
A synchronous machine may operate as a generator and as such becomes a member... | direct |
| gen_unit_op_schedule | 0..1 GenUnitOpSchedule |
A generating unit may have an operating schedule, indicating the planned oper... | direct |
| control_area_generating_unit | 0..* ControlAreaGeneratingUnit |
ControlArea specifications for this generating unit | direct |
| gross_to_net_active_power_curves | 0..* GrossToNetActivePowerCurve |
A generating unit may have a gross active power to net active power curve, de... | direct |
| gen_unit_op_cost_curves | 0..* GenUnitOpCostCurve |
A generating unit may have one or more cost curves, depending upon fuel mixtu... | direct |
| aggregate | 0..1 Boolean |
The aggregate flag provides an alternative way of representing an aggregated ... | Equipment |
| in_service | 0..1 Boolean |
Specifies the availability of the equipment | Equipment |
| network_analysis_enabled | 0..1 Boolean |
The equipment is enabled to participate in network analysis | Equipment |
| normally_in_service | 0..1 Boolean |
Specifies the availability of the equipment under normal operating conditions | Equipment |
| weather_station | 0..* WeatherStation |
Equipment | |
| operational_limit_set | 0..* OperationalLimitSet |
The operational limit sets associated with this equipment | Equipment |
| contingency_equipment | 0..* ContingencyEquipment |
The contingency equipments in which this equipment participates | Equipment |
| equipment_container | 0..1 EquipmentContainer |
Container of this equipment | Equipment |
| faults | 0..* Fault |
All faults on this equipment | Equipment |
| limit_dependency_model | 0..* LimitDependency |
Limit dependencymodels organized under this equipment as a means for organizi... | Equipment |
| eqiupment_limit_series_component | 0..* EquipmentLimitSeriesComponent |
Equipment limit series calculation component to which this equipment contribu... | Equipment |
| protective_action_equipment | 0..* ProtectiveActionEquipment |
Protective action is controlling equipment | Equipment |
| pin_equipment | 0..* PinEquipment |
Equipment | |
| equipment_unavailability_schedule | 0..* EquipmentUnavailabilitySchedule |
Equipment | |
| additional_equipment_container | 0..* EquipmentContainer |
Additional equipment container beyond the primary equipment container | Equipment |
| usage_points | 0..* UsagePoint |
All usage points connected to the electrical grid through this equipment | Equipment |
| outages | 0..* Outage |
All outages in which this equipment is involved | Equipment |
| operational_restrictions | 0..* OperationalRestriction |
All operational restrictions for this equipment | Equipment |
| controls | 0..* Control |
The controller outputs used to actually govern a regulating device, e | PowerSystemResource |
| measurements | 0..* Measurement |
The measurements associated with this power system resource | PowerSystemResource |
| psrtype | 0..1 PSRType |
Custom classification for this power system resource | PowerSystemResource |
| configuration_event | 0..* ConfigurationEvent |
All configuration events created for this Power System resource | PowerSystemResource |
| reporting_group | 0..* ReportingGroup |
Reporting groups to which this power system resource belongs | PowerSystemResource |
| operating_share | 0..* OperatingShare |
The operating shares of this power system resource | PowerSystemResource |
| asset_datasheet | 0..1 AssetInfo |
Datasheet information for this power system resource | PowerSystemResource |
| verification_action | 0..* VerificationAction |
The verification action that is performed on the power system resource | PowerSystemResource |
| clearances | 0..* ClearanceDocument |
All clearances applicable to this power system resource | PowerSystemResource |
| generic_action | 0..* GenericAction |
The generic action that is performed on the power system resource | PowerSystemResource |
| psrevents | 0..* PSREvent |
All events associated with this power system resource | PowerSystemResource |
| assets | 0..* Asset |
All assets represented by this power system resource | PowerSystemResource |
| location | 0..1 Location |
Location of this power system resource | PowerSystemResource |
| operational_tags | 0..* OperationalTag |
All operational tags placed on this power system resource | PowerSystemResource |
| alias_name | 0..1 String |
The aliasName is free text human readable name of the object alternative to I... | IdentifiedObject |
| description | 0..1 String |
The description is a free human readable text describing or naming the object | IdentifiedObject |
| m_rid | 0..1 String |
Master resource identifier issued by a model authority | IdentifiedObject |
| diagram_objects | 0..* DiagramObject |
The diagram objects that are associated with the domain object | IdentifiedObject |
| instance_set | 1..1 InstanceSet |
Dataset containing the data objects | IdentifiedObject |
| names | 0..* Name |
All names of this identified object | IdentifiedObject |
| properties_cimdata_object | 0..1 ChangeSetMember |
The single CIM data object in the appropriate dataset context | IdentifiedObject |
| targeting_cimdata_object | 0..* ChangeSetMember |
Data objects registered | IdentifiedObject |
Usages
| used by | used in | type | used |
|---|---|---|---|
| GenUnitOpSchedule | generating_unit | range | GeneratingUnit |
| ControlAreaGeneratingUnit | generating_unit | range | GeneratingUnit |
| GrossToNetActivePowerCurve | generating_unit | range | GeneratingUnit |
| GenUnitOpCostCurve | generating_unit | range | GeneratingUnit |
| RotatingMachine | generating_unit | range | GeneratingUnit |
| SynchronousMachine | generating_unit | range | GeneratingUnit |
| AsynchronousMachine | generating_unit | range | GeneratingUnit |
Identifier and Mapping Information
Schema Source
- from schema: https://cim.ucaiug.io/ns#TC57CIM
Mappings
| Mapping Type | Mapped Value |
|---|---|
| self | cim:GeneratingUnit |
| native | cim:GeneratingUnit |
LinkML Source
Direct
name: GeneratingUnit
description: A single or set of synchronous machines for converting mechanical power
into alternating-current power. For example, individual machines within a set may
be defined for scheduling purposes while a single control signal is derived for
the set. In this case there would be a GeneratingUnit for each member of the set
and an additional GeneratingUnit corresponding to the set.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
is_a: Equipment
attributes:
alloc_spin_res_p:
name: alloc_spin_res_p
description: "The planned unused capacity (spinning reserve) which can be used\
\ to support emergency load.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.allocSpinResP
multivalued: false
domain_of:
- GeneratingUnit
range: ActivePower
required: false
auto_cntrl_margin_p:
name: auto_cntrl_margin_p
description: The planned unused capacity which can be used to support automatic
control overruns.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.autoCntrlMarginP
multivalued: false
domain_of:
- GeneratingUnit
range: ActivePower
required: false
base_p:
name: base_p
description: For dispatchable units, this value represents the economic active
power basepoint, for units that are not dispatchable, this value represents
the fixed generation value. The value shall be between the operating low and
high limits.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.baseP
multivalued: false
domain_of:
- GeneratingUnit
range: ActivePower
required: false
control_deadband:
name: control_deadband
description: Unit control error deadband. When a unit's desired active power change
is less than this deadband, then no control pulses will be sent to the unit.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.controlDeadband
multivalued: false
domain_of:
- GeneratingUnit
range: ActivePower
required: false
control_pulse_high:
name: control_pulse_high
description: "Pulse high limit which is the largest control pulse that the unit\
\ can respond to.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.controlPulseHigh
multivalued: false
domain_of:
- GeneratingUnit
range: Seconds
required: false
control_pulse_low:
name: control_pulse_low
description: "Pulse low limit which is the smallest control pulse that the unit\
\ can respond to.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.controlPulseLow
multivalued: false
domain_of:
- GeneratingUnit
range: Seconds
required: false
control_response_rate:
name: control_response_rate
description: Unit response rate which specifies the active power change for a
control pulse of one second in the most responsive loading level of the unit.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.controlResponseRate
multivalued: false
domain_of:
- GeneratingUnit
range: ActivePowerChangeRate
required: false
efficiency:
name: efficiency
description: The efficiency of the unit in converting mechanical energy, from
the prime mover, into electrical energy.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.efficiency
multivalued: false
domain_of:
- GeneratingUnit
- AsynchronousMachine
range: PerCent
required: false
gen_control_mode:
name: gen_control_mode
description: The unit control mode.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.genControlMode
multivalued: false
domain_of:
- GeneratingUnit
range: GeneratorControlMode
required: false
gen_control_source:
name: gen_control_source
description: The source of controls for a generating unit. Defines the control
status of the generating unit.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.genControlSource
multivalued: false
domain_of:
- GeneratingUnit
range: GeneratorControlSource
required: false
governor_mpl:
name: governor_mpl
description: "Governor motor position limit.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.governorMPL
multivalued: false
domain_of:
- GeneratingUnit
range: PU
required: false
governor_scd:
name: governor_scd
description: Governor Speed Changer Droop. This is the change in generator power
output divided by the change in frequency normalized by the nominal power of
the generator and the nominal frequency and expressed in percent and negated.
A positive value of speed change droop provides additional generator output
upon a drop in frequency.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.governorSCD
multivalued: false
domain_of:
- GeneratingUnit
- ExternalNetworkInjection
range: PerCent
required: false
high_control_limit:
name: high_control_limit
description: "High limit for secondary (AGC) control.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GeneratingUnit.highControlLimit
multivalued: false
domain_of:
- RegisteredGenerator
- GeneratingUnit
range: ActivePower
required: false
initial_p:
name: initial_p
description: "Default initial active power which is used to store a powerflow\
\ result for the initial active power for this unit in this network configuration.\r\
\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.initialP
multivalued: false
domain_of:
- GeneratingUnit
range: ActivePower
required: false
long_pf:
name: long_pf
description: "Generating unit long term economic participation factor.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.longPF
multivalued: false
domain_of:
- GeneratingUnit
range: float
required: false
low_control_limit:
name: low_control_limit
description: "Low limit for secondary (AGC) control.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GeneratingUnit.lowControlLimit
multivalued: false
domain_of:
- RegisteredGenerator
- GeneratingUnit
range: ActivePower
required: false
lower_ramp_rate:
name: lower_ramp_rate
description: "The normal maximum rate the generating unit active power output\
\ can be lowered by control actions.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GeneratingUnit.lowerRampRate
multivalued: false
domain_of:
- GeneratingBid
- GeneratingUnit
range: ActivePowerChangeRate
required: false
max_economic_p:
name: max_economic_p
description: "Maximum high economic active power limit, that should not exceed\
\ the maximum operating active power limit.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.maxEconomicP
multivalued: false
domain_of:
- GeneratingUnit
range: ActivePower
required: false
maximum_allowable_spinning_reserve:
name: maximum_allowable_spinning_reserve
description: Maximum allowable spinning reserve. Spinning reserve will never be
considered greater than this value regardless of the current operating point.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GeneratingUnit.maximumAllowableSpinningReserve
multivalued: false
domain_of:
- RegisteredGenerator
- GeneratingUnit
range: ActivePower
required: false
max_operating_p:
name: max_operating_p
description: "This is the maximum operating active power limit the dispatcher\
\ can enter for this unit.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.maxOperatingP
multivalued: false
domain_of:
- GeneratingUnit
range: ActivePower
required: false
min_economic_p:
name: min_economic_p
description: Low economic active power limit that shall be greater than or equal
to the minimum operating active power limit.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.minEconomicP
multivalued: false
domain_of:
- GeneratingUnit
range: ActivePower
required: false
minimum_off_time:
name: minimum_off_time
description: "Minimum time interval between unit shutdown and startup.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.minimumOffTime
multivalued: false
domain_of:
- GeneratingUnit
range: Seconds
required: false
min_operating_p:
name: min_operating_p
description: This is the minimum operating active power limit the dispatcher can
enter for this unit.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.minOperatingP
multivalued: false
domain_of:
- GeneratingUnit
range: ActivePower
required: false
model_detail:
name: model_detail
description: "Detail level of the generator model data.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.modelDetail
multivalued: false
domain_of:
- GeneratingUnit
range: Classification
required: false
nominal_p:
name: nominal_p
description: "The nominal power of the generating unit. Used to give precise\
\ meaning to percentage based attributes such as the governor speed change droop\
\ (governorSCD attribute).\r\nThe attribute shall be a positive value equal\
\ to or less than RotatingMachine.ratedS."
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.nominalP
multivalued: false
domain_of:
- GeneratingUnit
range: ActivePower
required: false
normal_pf:
name: normal_pf
description: Generating unit economic participation factor. The sum of the participation
factors across generating units does not have to sum to one. It is used for
representing distributed slack participation factor. The attribute shall be
a positive value or zero.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.normalPF
multivalued: false
domain_of:
- GeneratingUnit
range: float
required: false
penalty_factor:
name: penalty_factor
description: 'Defined as: 1 / ( 1 - Incremental Transmission Loss); with the Incremental
Transmission Loss expressed as a plus or minus value. The typical range of penalty
factors is (0.9 to 1.1).'
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.penaltyFactor
multivalued: false
domain_of:
- GeneratingUnit
range: float
required: false
raise_ramp_rate:
name: raise_ramp_rate
description: "The normal maximum rate the generating unit active power output\
\ can be raised by control actions.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GeneratingUnit.raiseRampRate
multivalued: false
domain_of:
- GeneratingBid
- GeneratingUnit
range: ActivePowerChangeRate
required: false
rated_gross_max_p:
name: rated_gross_max_p
description: "The unit's gross rated maximum capacity (book value).\r\nThe attribute\
\ shall be a positive value.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.ratedGrossMaxP
multivalued: false
domain_of:
- GeneratingUnit
range: ActivePower
required: false
rated_gross_min_p:
name: rated_gross_min_p
description: "The gross rated minimum generation level which the unit can safely\
\ operate at while delivering power to the transmission grid.\r\nThe attribute\
\ shall be a positive value.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.ratedGrossMinP
multivalued: false
domain_of:
- GeneratingUnit
range: ActivePower
required: false
rated_net_max_p:
name: rated_net_max_p
description: "The net rated maximum capacity determined by subtracting the auxiliary\
\ power used to operate the internal plant machinery from the rated gross maximum\
\ capacity.\r\nThe attribute shall be a positive value.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.ratedNetMaxP
multivalued: false
domain_of:
- GeneratingUnit
range: ActivePower
required: false
short_pf:
name: short_pf
description: "Generating unit short term economic participation factor.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.shortPF
multivalued: false
domain_of:
- GeneratingUnit
range: float
required: false
startup_cost:
name: startup_cost
description: The initial startup cost incurred for each start of the GeneratingUnit.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GeneratingUnit.startupCost
multivalued: false
domain_of:
- GeneratingBid
- GeneratingUnit
- StartupModel
range: Money
required: false
startup_time:
name: startup_time
description: "Time it takes to get the unit on-line, from the time that the prime\
\ mover mechanical power is applied.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.startupTime
multivalued: false
domain_of:
- GeneratingUnit
range: Seconds
required: false
tie_line_pf:
name: tie_line_pf
description: "Generating unit economic participation factor.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.tieLinePF
multivalued: false
domain_of:
- GeneratingUnit
range: float
required: false
total_efficiency:
name: total_efficiency
description: The efficiency of the unit in converting the fuel into electrical
energy.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.totalEfficiency
multivalued: false
domain_of:
- GeneratingUnit
range: PerCent
required: false
variable_cost:
name: variable_cost
description: The variable cost component of production per unit of ActivePower.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.variableCost
multivalued: false
domain_of:
- GeneratingUnit
range: Money
required: false
rotating_machine:
name: rotating_machine
description: A synchronous machine may operate as a generator and as such becomes
a member of a generating unit.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.RotatingMachine
multivalued: true
domain_of:
- GeneratingUnit
- HydroPump
range: RotatingMachine
required: false
gen_unit_op_schedule:
name: gen_unit_op_schedule
description: A generating unit may have an operating schedule, indicating the
planned operation of the unit.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.GenUnitOpSchedule
multivalued: false
domain_of:
- GeneratingUnit
range: GenUnitOpSchedule
required: false
control_area_generating_unit:
name: control_area_generating_unit
description: ControlArea specifications for this generating unit.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.ControlAreaGeneratingUnit
multivalued: true
domain_of:
- GeneratingUnit
- AltGeneratingUnitMeas
- ControlArea
range: ControlAreaGeneratingUnit
required: false
gross_to_net_active_power_curves:
name: gross_to_net_active_power_curves
description: A generating unit may have a gross active power to net active power
curve, describing the losses and auxiliary power requirements of the unit.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.GrossToNetActivePowerCurves
multivalued: true
domain_of:
- GeneratingUnit
range: GrossToNetActivePowerCurve
required: false
gen_unit_op_cost_curves:
name: gen_unit_op_cost_curves
description: A generating unit may have one or more cost curves, depending upon
fuel mixture and fuel cost.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.GenUnitOpCostCurves
multivalued: true
domain_of:
- GeneratingUnit
range: GenUnitOpCostCurve
required: false
class_uri: cim:GeneratingUnit
Induced
name: GeneratingUnit
description: A single or set of synchronous machines for converting mechanical power
into alternating-current power. For example, individual machines within a set may
be defined for scheduling purposes while a single control signal is derived for
the set. In this case there would be a GeneratingUnit for each member of the set
and an additional GeneratingUnit corresponding to the set.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
is_a: Equipment
attributes:
alloc_spin_res_p:
name: alloc_spin_res_p
description: "The planned unused capacity (spinning reserve) which can be used\
\ to support emergency load.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.allocSpinResP
multivalued: false
alias: alloc_spin_res_p
owner: GeneratingUnit
domain_of:
- GeneratingUnit
range: ActivePower
required: false
auto_cntrl_margin_p:
name: auto_cntrl_margin_p
description: The planned unused capacity which can be used to support automatic
control overruns.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.autoCntrlMarginP
multivalued: false
alias: auto_cntrl_margin_p
owner: GeneratingUnit
domain_of:
- GeneratingUnit
range: ActivePower
required: false
base_p:
name: base_p
description: For dispatchable units, this value represents the economic active
power basepoint, for units that are not dispatchable, this value represents
the fixed generation value. The value shall be between the operating low and
high limits.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.baseP
multivalued: false
alias: base_p
owner: GeneratingUnit
domain_of:
- GeneratingUnit
range: ActivePower
required: false
control_deadband:
name: control_deadband
description: Unit control error deadband. When a unit's desired active power change
is less than this deadband, then no control pulses will be sent to the unit.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.controlDeadband
multivalued: false
alias: control_deadband
owner: GeneratingUnit
domain_of:
- GeneratingUnit
range: ActivePower
required: false
control_pulse_high:
name: control_pulse_high
description: "Pulse high limit which is the largest control pulse that the unit\
\ can respond to.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.controlPulseHigh
multivalued: false
alias: control_pulse_high
owner: GeneratingUnit
domain_of:
- GeneratingUnit
range: Seconds
required: false
control_pulse_low:
name: control_pulse_low
description: "Pulse low limit which is the smallest control pulse that the unit\
\ can respond to.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.controlPulseLow
multivalued: false
alias: control_pulse_low
owner: GeneratingUnit
domain_of:
- GeneratingUnit
range: Seconds
required: false
control_response_rate:
name: control_response_rate
description: Unit response rate which specifies the active power change for a
control pulse of one second in the most responsive loading level of the unit.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.controlResponseRate
multivalued: false
alias: control_response_rate
owner: GeneratingUnit
domain_of:
- GeneratingUnit
range: ActivePowerChangeRate
required: false
efficiency:
name: efficiency
description: The efficiency of the unit in converting mechanical energy, from
the prime mover, into electrical energy.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.efficiency
multivalued: false
alias: efficiency
owner: GeneratingUnit
domain_of:
- GeneratingUnit
- AsynchronousMachine
range: PerCent
required: false
gen_control_mode:
name: gen_control_mode
description: The unit control mode.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.genControlMode
multivalued: false
alias: gen_control_mode
owner: GeneratingUnit
domain_of:
- GeneratingUnit
range: GeneratorControlMode
required: false
gen_control_source:
name: gen_control_source
description: The source of controls for a generating unit. Defines the control
status of the generating unit.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.genControlSource
multivalued: false
alias: gen_control_source
owner: GeneratingUnit
domain_of:
- GeneratingUnit
range: GeneratorControlSource
required: false
governor_mpl:
name: governor_mpl
description: "Governor motor position limit.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.governorMPL
multivalued: false
alias: governor_mpl
owner: GeneratingUnit
domain_of:
- GeneratingUnit
range: PU
required: false
governor_scd:
name: governor_scd
description: Governor Speed Changer Droop. This is the change in generator power
output divided by the change in frequency normalized by the nominal power of
the generator and the nominal frequency and expressed in percent and negated.
A positive value of speed change droop provides additional generator output
upon a drop in frequency.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.governorSCD
multivalued: false
alias: governor_scd
owner: GeneratingUnit
domain_of:
- GeneratingUnit
- ExternalNetworkInjection
range: PerCent
required: false
high_control_limit:
name: high_control_limit
description: "High limit for secondary (AGC) control.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GeneratingUnit.highControlLimit
multivalued: false
alias: high_control_limit
owner: GeneratingUnit
domain_of:
- RegisteredGenerator
- GeneratingUnit
range: ActivePower
required: false
initial_p:
name: initial_p
description: "Default initial active power which is used to store a powerflow\
\ result for the initial active power for this unit in this network configuration.\r\
\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.initialP
multivalued: false
alias: initial_p
owner: GeneratingUnit
domain_of:
- GeneratingUnit
range: ActivePower
required: false
long_pf:
name: long_pf
description: "Generating unit long term economic participation factor.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.longPF
multivalued: false
alias: long_pf
owner: GeneratingUnit
domain_of:
- GeneratingUnit
range: float
required: false
low_control_limit:
name: low_control_limit
description: "Low limit for secondary (AGC) control.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GeneratingUnit.lowControlLimit
multivalued: false
alias: low_control_limit
owner: GeneratingUnit
domain_of:
- RegisteredGenerator
- GeneratingUnit
range: ActivePower
required: false
lower_ramp_rate:
name: lower_ramp_rate
description: "The normal maximum rate the generating unit active power output\
\ can be lowered by control actions.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GeneratingUnit.lowerRampRate
multivalued: false
alias: lower_ramp_rate
owner: GeneratingUnit
domain_of:
- GeneratingBid
- GeneratingUnit
range: ActivePowerChangeRate
required: false
max_economic_p:
name: max_economic_p
description: "Maximum high economic active power limit, that should not exceed\
\ the maximum operating active power limit.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.maxEconomicP
multivalued: false
alias: max_economic_p
owner: GeneratingUnit
domain_of:
- GeneratingUnit
range: ActivePower
required: false
maximum_allowable_spinning_reserve:
name: maximum_allowable_spinning_reserve
description: Maximum allowable spinning reserve. Spinning reserve will never be
considered greater than this value regardless of the current operating point.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GeneratingUnit.maximumAllowableSpinningReserve
multivalued: false
alias: maximum_allowable_spinning_reserve
owner: GeneratingUnit
domain_of:
- RegisteredGenerator
- GeneratingUnit
range: ActivePower
required: false
max_operating_p:
name: max_operating_p
description: "This is the maximum operating active power limit the dispatcher\
\ can enter for this unit.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.maxOperatingP
multivalued: false
alias: max_operating_p
owner: GeneratingUnit
domain_of:
- GeneratingUnit
range: ActivePower
required: false
min_economic_p:
name: min_economic_p
description: Low economic active power limit that shall be greater than or equal
to the minimum operating active power limit.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.minEconomicP
multivalued: false
alias: min_economic_p
owner: GeneratingUnit
domain_of:
- GeneratingUnit
range: ActivePower
required: false
minimum_off_time:
name: minimum_off_time
description: "Minimum time interval between unit shutdown and startup.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.minimumOffTime
multivalued: false
alias: minimum_off_time
owner: GeneratingUnit
domain_of:
- GeneratingUnit
range: Seconds
required: false
min_operating_p:
name: min_operating_p
description: This is the minimum operating active power limit the dispatcher can
enter for this unit.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.minOperatingP
multivalued: false
alias: min_operating_p
owner: GeneratingUnit
domain_of:
- GeneratingUnit
range: ActivePower
required: false
model_detail:
name: model_detail
description: "Detail level of the generator model data.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.modelDetail
multivalued: false
alias: model_detail
owner: GeneratingUnit
domain_of:
- GeneratingUnit
range: Classification
required: false
nominal_p:
name: nominal_p
description: "The nominal power of the generating unit. Used to give precise\
\ meaning to percentage based attributes such as the governor speed change droop\
\ (governorSCD attribute).\r\nThe attribute shall be a positive value equal\
\ to or less than RotatingMachine.ratedS."
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.nominalP
multivalued: false
alias: nominal_p
owner: GeneratingUnit
domain_of:
- GeneratingUnit
range: ActivePower
required: false
normal_pf:
name: normal_pf
description: Generating unit economic participation factor. The sum of the participation
factors across generating units does not have to sum to one. It is used for
representing distributed slack participation factor. The attribute shall be
a positive value or zero.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.normalPF
multivalued: false
alias: normal_pf
owner: GeneratingUnit
domain_of:
- GeneratingUnit
range: float
required: false
penalty_factor:
name: penalty_factor
description: 'Defined as: 1 / ( 1 - Incremental Transmission Loss); with the Incremental
Transmission Loss expressed as a plus or minus value. The typical range of penalty
factors is (0.9 to 1.1).'
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.penaltyFactor
multivalued: false
alias: penalty_factor
owner: GeneratingUnit
domain_of:
- GeneratingUnit
range: float
required: false
raise_ramp_rate:
name: raise_ramp_rate
description: "The normal maximum rate the generating unit active power output\
\ can be raised by control actions.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GeneratingUnit.raiseRampRate
multivalued: false
alias: raise_ramp_rate
owner: GeneratingUnit
domain_of:
- GeneratingBid
- GeneratingUnit
range: ActivePowerChangeRate
required: false
rated_gross_max_p:
name: rated_gross_max_p
description: "The unit's gross rated maximum capacity (book value).\r\nThe attribute\
\ shall be a positive value.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.ratedGrossMaxP
multivalued: false
alias: rated_gross_max_p
owner: GeneratingUnit
domain_of:
- GeneratingUnit
range: ActivePower
required: false
rated_gross_min_p:
name: rated_gross_min_p
description: "The gross rated minimum generation level which the unit can safely\
\ operate at while delivering power to the transmission grid.\r\nThe attribute\
\ shall be a positive value.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.ratedGrossMinP
multivalued: false
alias: rated_gross_min_p
owner: GeneratingUnit
domain_of:
- GeneratingUnit
range: ActivePower
required: false
rated_net_max_p:
name: rated_net_max_p
description: "The net rated maximum capacity determined by subtracting the auxiliary\
\ power used to operate the internal plant machinery from the rated gross maximum\
\ capacity.\r\nThe attribute shall be a positive value.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.ratedNetMaxP
multivalued: false
alias: rated_net_max_p
owner: GeneratingUnit
domain_of:
- GeneratingUnit
range: ActivePower
required: false
short_pf:
name: short_pf
description: "Generating unit short term economic participation factor.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.shortPF
multivalued: false
alias: short_pf
owner: GeneratingUnit
domain_of:
- GeneratingUnit
range: float
required: false
startup_cost:
name: startup_cost
description: The initial startup cost incurred for each start of the GeneratingUnit.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:GeneratingUnit.startupCost
multivalued: false
alias: startup_cost
owner: GeneratingUnit
domain_of:
- GeneratingBid
- GeneratingUnit
- StartupModel
range: Money
required: false
startup_time:
name: startup_time
description: "Time it takes to get the unit on-line, from the time that the prime\
\ mover mechanical power is applied.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.startupTime
multivalued: false
alias: startup_time
owner: GeneratingUnit
domain_of:
- GeneratingUnit
range: Seconds
required: false
tie_line_pf:
name: tie_line_pf
description: "Generating unit economic participation factor.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.tieLinePF
multivalued: false
alias: tie_line_pf
owner: GeneratingUnit
domain_of:
- GeneratingUnit
range: float
required: false
total_efficiency:
name: total_efficiency
description: The efficiency of the unit in converting the fuel into electrical
energy.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.totalEfficiency
multivalued: false
alias: total_efficiency
owner: GeneratingUnit
domain_of:
- GeneratingUnit
range: PerCent
required: false
variable_cost:
name: variable_cost
description: The variable cost component of production per unit of ActivePower.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.variableCost
multivalued: false
alias: variable_cost
owner: GeneratingUnit
domain_of:
- GeneratingUnit
range: Money
required: false
rotating_machine:
name: rotating_machine
description: A synchronous machine may operate as a generator and as such becomes
a member of a generating unit.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.RotatingMachine
multivalued: true
alias: rotating_machine
owner: GeneratingUnit
domain_of:
- GeneratingUnit
- HydroPump
range: RotatingMachine
required: false
gen_unit_op_schedule:
name: gen_unit_op_schedule
description: A generating unit may have an operating schedule, indicating the
planned operation of the unit.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.GenUnitOpSchedule
multivalued: false
alias: gen_unit_op_schedule
owner: GeneratingUnit
domain_of:
- GeneratingUnit
range: GenUnitOpSchedule
required: false
control_area_generating_unit:
name: control_area_generating_unit
description: ControlArea specifications for this generating unit.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.ControlAreaGeneratingUnit
multivalued: true
alias: control_area_generating_unit
owner: GeneratingUnit
domain_of:
- GeneratingUnit
- AltGeneratingUnitMeas
- ControlArea
range: ControlAreaGeneratingUnit
required: false
gross_to_net_active_power_curves:
name: gross_to_net_active_power_curves
description: A generating unit may have a gross active power to net active power
curve, describing the losses and auxiliary power requirements of the unit.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.GrossToNetActivePowerCurves
multivalued: true
alias: gross_to_net_active_power_curves
owner: GeneratingUnit
domain_of:
- GeneratingUnit
range: GrossToNetActivePowerCurve
required: false
gen_unit_op_cost_curves:
name: gen_unit_op_cost_curves
description: A generating unit may have one or more cost curves, depending upon
fuel mixture and fuel cost.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:GeneratingUnit.GenUnitOpCostCurves
multivalued: true
alias: gen_unit_op_cost_curves
owner: GeneratingUnit
domain_of:
- GeneratingUnit
range: GenUnitOpCostCurve
required: false
aggregate:
name: aggregate
description: "The aggregate flag provides an alternative way of representing an\
\ aggregated (equivalent) element. It is applicable in cases when the dedicated\
\ classes for equivalent equipment do not have all of the attributes necessary\
\ to represent the required level of detail. In case the flag is set to “true”\
\ the single instance of equipment represents multiple pieces of equipment that\
\ have been modelled together as an aggregate equivalent obtained by a network\
\ reduction procedure. Examples would be power transformers or synchronous machines\
\ operating in parallel modelled as a single aggregate power transformer or\
\ aggregate synchronous machine. \r\nThe attribute is not used for EquivalentBranch,\
\ EquivalentShunt and EquivalentInjection."
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.aggregate
multivalued: false
alias: aggregate
owner: GeneratingUnit
domain_of:
- Equipment
- ReadingType
range: boolean
required: false
in_service:
name: in_service
description: Specifies the availability of the equipment. True means the equipment
is available for topology processing, which determines if the equipment is energized
or not. False means that the equipment is treated by network applications as
if it is not in the model.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.inService
multivalued: false
alias: in_service
owner: GeneratingUnit
domain_of:
- Equipment
- SvStatus
- ProtectiveActionEquipment
range: boolean
required: false
network_analysis_enabled:
name: network_analysis_enabled
description: The equipment is enabled to participate in network analysis. If
unspecified, the value is assumed to be true.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.networkAnalysisEnabled
multivalued: false
alias: network_analysis_enabled
owner: GeneratingUnit
domain_of:
- Equipment
range: boolean
required: false
normally_in_service:
name: normally_in_service
description: Specifies the availability of the equipment under normal operating
conditions. True means the equipment is available for topology processing, which
determines if the equipment is energized or not. False means that the equipment
is treated by network applications as if it is not in the model.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.normallyInService
multivalued: false
alias: normally_in_service
owner: GeneratingUnit
domain_of:
- Equipment
range: boolean
required: false
weather_station:
name: weather_station
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.WeatherStation
multivalued: true
alias: weather_station
owner: GeneratingUnit
domain_of:
- Equipment
range: WeatherStation
required: false
operational_limit_set:
name: operational_limit_set
description: The operational limit sets associated with this equipment.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:Equipment.OperationalLimitSet
multivalued: true
alias: operational_limit_set
owner: GeneratingUnit
domain_of:
- ACDCTerminal
- OperationalLimit
- Equipment
range: OperationalLimitSet
required: false
contingency_equipment:
name: contingency_equipment
description: The contingency equipments in which this equipment participates.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.ContingencyEquipment
multivalued: true
alias: contingency_equipment
owner: GeneratingUnit
domain_of:
- Equipment
range: ContingencyEquipment
required: false
equipment_container:
name: equipment_container
description: Container of this equipment.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.EquipmentContainer
multivalued: false
alias: equipment_container
owner: GeneratingUnit
domain_of:
- Equipment
range: EquipmentContainer
required: false
faults:
name: faults
description: All faults on this equipment.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.Faults
multivalued: true
alias: faults
owner: GeneratingUnit
domain_of:
- Equipment
- Outage
- FaultCauseType
range: Fault
required: false
limit_dependency_model:
name: limit_dependency_model
description: Limit dependencymodels organized under this equipment as a means
for organizing the model in a tree view.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:Equipment.LimitDependencyModel
multivalued: true
alias: limit_dependency_model
owner: GeneratingUnit
domain_of:
- OperationalLimit
- Equipment
range: LimitDependency
required: false
eqiupment_limit_series_component:
name: eqiupment_limit_series_component
description: Equipment limit series calculation component to which this equipment
contributes.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.EqiupmentLimitSeriesComponent
multivalued: true
alias: eqiupment_limit_series_component
owner: GeneratingUnit
domain_of:
- Equipment
range: EquipmentLimitSeriesComponent
required: false
protective_action_equipment:
name: protective_action_equipment
description: Protective action is controlling equipment. This can be direct signals
from the control center, or emulation of action done by protection equipment.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.ProtectiveActionEquipment
multivalued: true
alias: protective_action_equipment
owner: GeneratingUnit
domain_of:
- Equipment
range: ProtectiveActionEquipment
required: false
pin_equipment:
name: pin_equipment
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.PinEquipment
multivalued: true
alias: pin_equipment
owner: GeneratingUnit
domain_of:
- Equipment
range: PinEquipment
required: false
equipment_unavailability_schedule:
name: equipment_unavailability_schedule
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.EquipmentUnavailabilitySchedule
multivalued: true
alias: equipment_unavailability_schedule
owner: GeneratingUnit
domain_of:
- Equipment
- UnavailabilitySwitchAction
- UnavailablitySchedule
range: EquipmentUnavailabilitySchedule
required: false
additional_equipment_container:
name: additional_equipment_container
description: Additional equipment container beyond the primary equipment container. The
equipment is contained in another equipment container, but also grouped with
this equipment container.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.AdditionalEquipmentContainer
multivalued: true
alias: additional_equipment_container
owner: GeneratingUnit
domain_of:
- Equipment
range: EquipmentContainer
required: false
usage_points:
name: usage_points
description: All usage points connected to the electrical grid through this equipment.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.UsagePoints
multivalued: true
alias: usage_points
owner: GeneratingUnit
domain_of:
- Equipment
- CustomerAgreement
- ServiceCategory
- PricingStructure
- EndDeviceControl
- UsagePointGroup
- ServiceLocation
- MetrologyRequirement
- ServiceSupplier
- UsagePointLocation
range: UsagePoint
required: false
outages:
name: outages
description: All outages in which this equipment is involved.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.Outages
multivalued: true
alias: outages
owner: GeneratingUnit
domain_of:
- Equipment
range: Outage
required: false
operational_restrictions:
name: operational_restrictions
description: All operational restrictions for this equipment.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.OperationalRestrictions
multivalued: true
alias: operational_restrictions
owner: GeneratingUnit
domain_of:
- Equipment
- ProductAssetModel
range: OperationalRestriction
required: false
controls:
name: controls
description: The controller outputs used to actually govern a regulating device,
e.g. the magnetization of a synchronous machine or capacitor bank breaker actuator.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.Controls
multivalued: true
alias: controls
owner: GeneratingUnit
domain_of:
- PowerSystemResource
- HostControlArea
range: Control
required: false
measurements:
name: measurements
description: The measurements associated with this power system resource.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.Measurements
multivalued: true
alias: measurements
owner: GeneratingUnit
domain_of:
- PowerSystemResource
- ACDCTerminal
- Asset
- Location
- Procedure
- AnalogLimitSet
- AccumulatorLimitSet
range: Measurement
required: false
psrtype:
name: psrtype
description: Custom classification for this power system resource.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.PSRType
multivalued: false
alias: psrtype
owner: GeneratingUnit
domain_of:
- PowerSystemResource
range: PSRType
required: false
configuration_event:
name: configuration_event
description: All configuration events created for this Power System resource.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.ConfigurationEvent
multivalued: true
alias: configuration_event
owner: GeneratingUnit
domain_of:
- PowerSystemResource
- FaultCauseType
range: ConfigurationEvent
required: false
reporting_group:
name: reporting_group
description: Reporting groups to which this power system resource belongs.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.ReportingGroup
multivalued: true
alias: reporting_group
owner: GeneratingUnit
domain_of:
- PowerSystemResource
- BusNameMarker
- TopologicalNode
- ReportingSuperGroup
range: ReportingGroup
required: false
operating_share:
name: operating_share
description: The operating shares of this power system resource.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.OperatingShare
multivalued: true
alias: operating_share
owner: GeneratingUnit
domain_of:
- PowerSystemResource
- OperatingParticipant
range: OperatingShare
required: false
asset_datasheet:
name: asset_datasheet
description: Datasheet information for this power system resource.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.AssetDatasheet
multivalued: false
alias: asset_datasheet
owner: GeneratingUnit
domain_of:
- PowerSystemResource
range: AssetInfo
required: false
verification_action:
name: verification_action
description: The verification action that is performed on the power system resource
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.VerificationAction
multivalued: true
alias: verification_action
owner: GeneratingUnit
domain_of:
- PowerSystemResource
range: VerificationAction
required: false
clearances:
name: clearances
description: All clearances applicable to this power system resource.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.Clearances
multivalued: true
alias: clearances
owner: GeneratingUnit
domain_of:
- PowerSystemResource
range: ClearanceDocument
required: false
generic_action:
name: generic_action
description: The generic action that is performed on the power system resource
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.GenericAction
multivalued: true
alias: generic_action
owner: GeneratingUnit
domain_of:
- PowerSystemResource
range: GenericAction
required: false
psrevents:
name: psrevents
description: All events associated with this power system resource.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.PSREvents
multivalued: true
alias: psrevents
owner: GeneratingUnit
domain_of:
- PowerSystemResource
range: PSREvent
required: false
assets:
name: assets
description: All assets represented by this power system resource. For example,
multiple conductor assets are electrically modelled as a single AC line segment.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.Assets
multivalued: true
alias: assets
owner: GeneratingUnit
domain_of:
- PowerSystemResource
- AssetInfo
- Location
- WorkTask
- ErpRecDelvLineItem
- AssetContainer
- ActivityRecord
- Procedure
- ReliabilityInfo
- AssetPropertyCurve
- AssetOrganisationRole
- ScheduledEvent
range: Asset
required: false
location:
name: location
description: Location of this power system resource.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.Location
multivalued: false
alias: location
owner: GeneratingUnit
domain_of:
- PowerSystemResource
- Asset
- Incident
- SwitchingOrder
- TroubleOrder
- Crew
- Fault
- PointOfSale
- TroubleTicket
- OutageOrder
- EnvironmentalMonitoringStation
- EnvironmentalLocationType
- PositionPoint
- FailureEvent
range: Location
required: false
operational_tags:
name: operational_tags
description: All operational tags placed on this power system resource.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.OperationalTags
multivalued: true
alias: operational_tags
owner: GeneratingUnit
domain_of:
- PowerSystemResource
- Asset
range: OperationalTag
required: false
alias_name:
name: alias_name
description: "The aliasName is free text human readable name of the object alternative\
\ to IdentifiedObject.name. It may be non unique and may not correlate to a\
\ naming hierarchy.\r\nThe attribute aliasName is retained because of backwards\
\ compatibility between CIM relases. It is however recommended to replace aliasName\
\ with the Name class as aliasName is planned for retirement at a future time.\r\
\n\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.aliasName
multivalued: false
alias: alias_name
owner: GeneratingUnit
domain_of:
- IdentifiedObject
range: string
required: false
description:
name: description
description: The description is a free human readable text describing or naming
the object. It may be non unique and may not correlate to a naming hierarchy.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.description
multivalued: false
alias: description
owner: GeneratingUnit
domain_of:
- IdentifiedObject
- NameType
- NameTypeAuthority
- DataSet
- SwitchingStepGroup
- AreaReserveSpec
range: string
required: false
m_rid:
name: m_rid
description: "Master resource identifier issued by a model authority. The mRID\
\ is unique within an exchange context. Global uniqueness is easily achieved\
\ by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is\
\ strongly recommended.\r\nFor CIMXML data files in RDF syntax conforming to\
\ IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify\
\ CIM object elements."
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.mRID
multivalued: false
alias: m_rid
owner: GeneratingUnit
domain_of:
- IdentifiedObject
- DataSet
range: string
required: false
diagram_objects:
name: diagram_objects
description: The diagram objects that are associated with the domain object.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.DiagramObjects
multivalued: true
alias: diagram_objects
owner: GeneratingUnit
domain_of:
- IdentifiedObject
range: DiagramObject
required: false
instance_set:
name: instance_set
description: Dataset containing the data objects.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.InstanceSet
multivalued: false
alias: instance_set
owner: GeneratingUnit
domain_of:
- IdentifiedObject
range: InstanceSet
required: true
names:
name: names
description: All names of this identified object.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.Names
multivalued: true
alias: names
owner: GeneratingUnit
domain_of:
- IdentifiedObject
- NameType
range: Name
required: false
properties_cimdata_object:
name: properties_cimdata_object
description: The single CIM data object in the appropriate dataset context.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.PropertiesCIMDataObject
multivalued: false
alias: properties_cimdata_object
owner: GeneratingUnit
domain_of:
- IdentifiedObject
range: ChangeSetMember
required: false
targeting_cimdata_object:
name: targeting_cimdata_object
description: Data objects registered.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.TargetingCIMDataObject
multivalued: true
alias: targeting_cimdata_object
owner: GeneratingUnit
domain_of:
- IdentifiedObject
range: ChangeSetMember
required: false
class_uri: cim:GeneratingUnit