Class: ExternalNetworkInjection
This class represents the external network and it is used for IEC 60909 calculations.
URI: cim:ExternalNetworkInjection
classDiagram
class ExternalNetworkInjection
RegulatingCondEq <|-- ExternalNetworkInjection
ExternalNetworkInjection : additional_equipment_container
ExternalNetworkInjection --> EquipmentContainer : additional_equipment_container
ExternalNetworkInjection : aggregate
ExternalNetworkInjection : alias_name
ExternalNetworkInjection : asset_datasheet
ExternalNetworkInjection --> AssetInfo : asset_datasheet
ExternalNetworkInjection : assets
ExternalNetworkInjection --> Asset : assets
ExternalNetworkInjection : base_voltage
ExternalNetworkInjection --> BaseVoltage : base_voltage
ExternalNetworkInjection : clearances
ExternalNetworkInjection --> ClearanceDocument : clearances
ExternalNetworkInjection : configuration_event
ExternalNetworkInjection --> ConfigurationEvent : configuration_event
ExternalNetworkInjection : contingency_equipment
ExternalNetworkInjection --> ContingencyEquipment : contingency_equipment
ExternalNetworkInjection : control_enabled
ExternalNetworkInjection : controls
ExternalNetworkInjection --> Control : controls
ExternalNetworkInjection : description
ExternalNetworkInjection : diagram_objects
ExternalNetworkInjection --> DiagramObject : diagram_objects
ExternalNetworkInjection : energy_component
ExternalNetworkInjection --> EnergyComponent : energy_component
ExternalNetworkInjection : eqiupment_limit_series_component
ExternalNetworkInjection --> EquipmentLimitSeriesComponent : eqiupment_limit_series_component
ExternalNetworkInjection : equipment_container
ExternalNetworkInjection --> EquipmentContainer : equipment_container
ExternalNetworkInjection : equipment_unavailability_schedule
ExternalNetworkInjection --> EquipmentUnavailabilitySchedule : equipment_unavailability_schedule
ExternalNetworkInjection : faults
ExternalNetworkInjection --> Fault : faults
ExternalNetworkInjection : generic_action
ExternalNetworkInjection --> GenericAction : generic_action
ExternalNetworkInjection : governor_scd
ExternalNetworkInjection --> ActivePowerPerFrequency : governor_scd
ExternalNetworkInjection : grounding_action
ExternalNetworkInjection --> GroundAction : grounding_action
ExternalNetworkInjection : ik_second
ExternalNetworkInjection : in_service
ExternalNetworkInjection : instance_set
ExternalNetworkInjection --> InstanceSet : instance_set
ExternalNetworkInjection : jumping_action
ExternalNetworkInjection --> JumperAction : jumping_action
ExternalNetworkInjection : limit_dependency_model
ExternalNetworkInjection --> LimitDependency : limit_dependency_model
ExternalNetworkInjection : location
ExternalNetworkInjection --> Location : location
ExternalNetworkInjection : m_rid
ExternalNetworkInjection : max_initial_sym_sh_ccurrent
ExternalNetworkInjection --> CurrentFlow : max_initial_sym_sh_ccurrent
ExternalNetworkInjection : max_p
ExternalNetworkInjection --> ActivePower : max_p
ExternalNetworkInjection : max_q
ExternalNetworkInjection --> ReactivePower : max_q
ExternalNetworkInjection : max_r_to_x_ratio
ExternalNetworkInjection : max_z_to_z_ratio
ExternalNetworkInjection : measurements
ExternalNetworkInjection --> Measurement : measurements
ExternalNetworkInjection : min_initial_sym_sh_ccurrent
ExternalNetworkInjection --> CurrentFlow : min_initial_sym_sh_ccurrent
ExternalNetworkInjection : min_p
ExternalNetworkInjection --> ActivePower : min_p
ExternalNetworkInjection : min_q
ExternalNetworkInjection --> ReactivePower : min_q
ExternalNetworkInjection : min_r_to_x_ratio
ExternalNetworkInjection : min_z_to_z_ratio
ExternalNetworkInjection : names
ExternalNetworkInjection --> Name : names
ExternalNetworkInjection : network_analysis_enabled
ExternalNetworkInjection : normally_in_service
ExternalNetworkInjection : operating_share
ExternalNetworkInjection --> OperatingShare : operating_share
ExternalNetworkInjection : operational_limit_set
ExternalNetworkInjection --> OperationalLimitSet : operational_limit_set
ExternalNetworkInjection : operational_restrictions
ExternalNetworkInjection --> OperationalRestriction : operational_restrictions
ExternalNetworkInjection : operational_tags
ExternalNetworkInjection --> OperationalTag : operational_tags
ExternalNetworkInjection : outage
ExternalNetworkInjection --> Outage : outage
ExternalNetworkInjection : outages
ExternalNetworkInjection --> Outage : outages
ExternalNetworkInjection : p
ExternalNetworkInjection --> ActivePower : p
ExternalNetworkInjection : pin_equipment
ExternalNetworkInjection --> PinEquipment : pin_equipment
ExternalNetworkInjection : properties_cimdata_object
ExternalNetworkInjection --> ChangeSetMember : properties_cimdata_object
ExternalNetworkInjection : protection_equipments
ExternalNetworkInjection --> ProtectionEquipment : protection_equipments
ExternalNetworkInjection : protective_action_adjustment
ExternalNetworkInjection --> ProtectiveActionAdjustment : protective_action_adjustment
ExternalNetworkInjection : protective_action_equipment
ExternalNetworkInjection --> ProtectiveActionEquipment : protective_action_equipment
ExternalNetworkInjection : psrevents
ExternalNetworkInjection --> PSREvent : psrevents
ExternalNetworkInjection : psrtype
ExternalNetworkInjection --> PSRType : psrtype
ExternalNetworkInjection : q
ExternalNetworkInjection --> ReactivePower : q
ExternalNetworkInjection : reference_priority
ExternalNetworkInjection : regulating_control
ExternalNetworkInjection --> RegulatingControl : regulating_control
ExternalNetworkInjection : reporting_group
ExternalNetworkInjection --> ReportingGroup : reporting_group
ExternalNetworkInjection : sv_status
ExternalNetworkInjection --> SvStatus : sv_status
ExternalNetworkInjection : targeting_cimdata_object
ExternalNetworkInjection --> ChangeSetMember : targeting_cimdata_object
ExternalNetworkInjection : terminals
ExternalNetworkInjection --> Terminal : terminals
ExternalNetworkInjection : usage_points
ExternalNetworkInjection --> UsagePoint : usage_points
ExternalNetworkInjection : verification_action
ExternalNetworkInjection --> VerificationAction : verification_action
ExternalNetworkInjection : voltage_factor
ExternalNetworkInjection --> PU : voltage_factor
ExternalNetworkInjection : weather_station
ExternalNetworkInjection --> WeatherStation : weather_station
Inheritance
- IdentifiedObject
- PowerSystemResource
- Equipment
- ConductingEquipment
- EnergyConnection
- RegulatingCondEq
- ExternalNetworkInjection
- RegulatingCondEq
- EnergyConnection
- ConductingEquipment
- Equipment
- PowerSystemResource
Slots
| Name | Cardinality and Range | Description | Inheritance |
|---|---|---|---|
| governor_scd | 0..1 ActivePowerPerFrequency |
Power Frequency Bias | direct |
| ik_second | 0..1 Boolean |
Indicates whether initial symmetrical short-circuit current and power have be... | direct |
| max_initial_sym_sh_ccurrent | 0..1 CurrentFlow |
Maximum initial symmetrical short-circuit currents (Ik" max) in A (Ik" = Sk... | direct |
| max_p | 0..1 ActivePower |
Maximum active power of the injection | direct |
| max_q | 0..1 ReactivePower |
Maximum reactive power limit | direct |
| max_r_to_x_ratio | 0..1 Float |
Maximum ratio of positive sequence resistance of Network Feeder to its positi... | direct |
| max_z_to_z_ratio | 0..1 Float |
Maximum ratio of zero sequence impedance to its positive sequence impedance (... | direct |
| min_initial_sym_sh_ccurrent | 0..1 CurrentFlow |
Minimum initial symmetrical short-circuit currents (Ik" min) in A (Ik" = Sk"/... | direct |
| min_p | 0..1 ActivePower |
Minimum active power of the injection | direct |
| min_q | 0..1 ReactivePower |
Minimum reactive power limit | direct |
| min_r_to_x_ratio | 0..1 Float |
Minimum ratio of positive sequence resistance of Network Feeder to its positi... | direct |
| min_z_to_z_ratio | 0..1 Float |
Minimum ratio of zero sequence impedance to its positive sequence impedance (... | direct |
| p | 0..1 ActivePower |
Active power injection | direct |
| q | 0..1 ReactivePower |
Reactive power injection | direct |
| reference_priority | 0..1 Integer |
Priority of unit for use as powerflow voltage phase angle reference bus selec... | direct |
| voltage_factor | 0..1 PU |
Voltage factor in pu, which was used to calculate short-circuit current Ik" a... | direct |
| control_enabled | 0..1 Boolean |
Specifies the regulation status of the equipment | RegulatingCondEq |
| regulating_control | 0..1 RegulatingControl |
The regulating control scheme in which this equipment participates | RegulatingCondEq |
| energy_component | 0..* EnergyComponent |
EnergyConnection | |
| protective_action_adjustment | 0..* ProtectiveActionAdjustment |
The operating condition to the Conducting Equipment is changed when protectiv... | ConductingEquipment |
| sv_status | 0..* SvStatus |
The status state variable associated with this conducting equipment | ConductingEquipment |
| protection_equipments | 0..* ProtectionEquipment |
Protection equipment used to protect specific conducting equipment | ConductingEquipment |
| base_voltage | 0..1 BaseVoltage |
Base voltage of this conducting equipment | ConductingEquipment |
| terminals | 0..* Terminal |
Conducting equipment have terminals that may be connected to other conducting... | ConductingEquipment |
| jumping_action | 0..1 JumperAction |
Jumper action involving jumping operation on this conducting equipment | ConductingEquipment |
| grounding_action | 0..1 GroundAction |
Action involving grounding operation on this conducting equipment | ConductingEquipment |
| outage | 0..1 Outage |
The outage that is isolated by the outage isolation equipment | ConductingEquipment |
| aggregate | 0..1 Boolean |
The aggregate flag provides an alternative way of representing an aggregated ... | Equipment |
| in_service | 0..1 Boolean |
Specifies the availability of the equipment | Equipment |
| network_analysis_enabled | 0..1 Boolean |
The equipment is enabled to participate in network analysis | Equipment |
| normally_in_service | 0..1 Boolean |
Specifies the availability of the equipment under normal operating conditions | Equipment |
| weather_station | 0..* WeatherStation |
Equipment | |
| operational_limit_set | 0..* OperationalLimitSet |
The operational limit sets associated with this equipment | Equipment |
| contingency_equipment | 0..* ContingencyEquipment |
The contingency equipments in which this equipment participates | Equipment |
| equipment_container | 0..1 EquipmentContainer |
Container of this equipment | Equipment |
| faults | 0..* Fault |
All faults on this equipment | Equipment |
| limit_dependency_model | 0..* LimitDependency |
Limit dependencymodels organized under this equipment as a means for organizi... | Equipment |
| eqiupment_limit_series_component | 0..* EquipmentLimitSeriesComponent |
Equipment limit series calculation component to which this equipment contribu... | Equipment |
| protective_action_equipment | 0..* ProtectiveActionEquipment |
Protective action is controlling equipment | Equipment |
| pin_equipment | 0..* PinEquipment |
Equipment | |
| equipment_unavailability_schedule | 0..* EquipmentUnavailabilitySchedule |
Equipment | |
| additional_equipment_container | 0..* EquipmentContainer |
Additional equipment container beyond the primary equipment container | Equipment |
| usage_points | 0..* UsagePoint |
All usage points connected to the electrical grid through this equipment | Equipment |
| outages | 0..* Outage |
All outages in which this equipment is involved | Equipment |
| operational_restrictions | 0..* OperationalRestriction |
All operational restrictions for this equipment | Equipment |
| controls | 0..* Control |
The controller outputs used to actually govern a regulating device, e | PowerSystemResource |
| measurements | 0..* Measurement |
The measurements associated with this power system resource | PowerSystemResource |
| psrtype | 0..1 PSRType |
Custom classification for this power system resource | PowerSystemResource |
| configuration_event | 0..* ConfigurationEvent |
All configuration events created for this Power System resource | PowerSystemResource |
| reporting_group | 0..* ReportingGroup |
Reporting groups to which this power system resource belongs | PowerSystemResource |
| operating_share | 0..* OperatingShare |
The operating shares of this power system resource | PowerSystemResource |
| asset_datasheet | 0..1 AssetInfo |
Datasheet information for this power system resource | PowerSystemResource |
| verification_action | 0..* VerificationAction |
The verification action that is performed on the power system resource | PowerSystemResource |
| clearances | 0..* ClearanceDocument |
All clearances applicable to this power system resource | PowerSystemResource |
| generic_action | 0..* GenericAction |
The generic action that is performed on the power system resource | PowerSystemResource |
| psrevents | 0..* PSREvent |
All events associated with this power system resource | PowerSystemResource |
| assets | 0..* Asset |
All assets represented by this power system resource | PowerSystemResource |
| location | 0..1 Location |
Location of this power system resource | PowerSystemResource |
| operational_tags | 0..* OperationalTag |
All operational tags placed on this power system resource | PowerSystemResource |
| alias_name | 0..1 String |
The aliasName is free text human readable name of the object alternative to I... | IdentifiedObject |
| description | 0..1 String |
The description is a free human readable text describing or naming the object | IdentifiedObject |
| m_rid | 0..1 String |
Master resource identifier issued by a model authority | IdentifiedObject |
| diagram_objects | 0..* DiagramObject |
The diagram objects that are associated with the domain object | IdentifiedObject |
| instance_set | 1..1 InstanceSet |
Dataset containing the data objects | IdentifiedObject |
| names | 0..* Name |
All names of this identified object | IdentifiedObject |
| properties_cimdata_object | 0..1 ChangeSetMember |
The single CIM data object in the appropriate dataset context | IdentifiedObject |
| targeting_cimdata_object | 0..* ChangeSetMember |
Data objects registered | IdentifiedObject |
Identifier and Mapping Information
Schema Source
- from schema: https://cim.ucaiug.io/ns#TC57CIM
Mappings
| Mapping Type | Mapped Value |
|---|---|
| self | cim:ExternalNetworkInjection |
| native | cim:ExternalNetworkInjection |
LinkML Source
Direct
name: ExternalNetworkInjection
description: This class represents the external network and it is used for IEC 60909
calculations.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
is_a: RegulatingCondEq
attributes:
governor_scd:
name: governor_scd
description: Power Frequency Bias. This is the change in power injection divided
by the change in frequency and negated. A positive value of the power frequency
bias provides additional power injection upon a drop in frequency.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:ExternalNetworkInjection.governorSCD
multivalued: false
domain_of:
- GeneratingUnit
- ExternalNetworkInjection
range: ActivePowerPerFrequency
required: false
ik_second:
name: ik_second
description: Indicates whether initial symmetrical short-circuit current and power
have been calculated according to IEC (Ik"). Used only if short circuit calculations
are done according to superposition method.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ExternalNetworkInjection.ikSecond
multivalued: false
domain_of:
- ExternalNetworkInjection
range: boolean
required: false
max_initial_sym_sh_ccurrent:
name: max_initial_sym_sh_ccurrent
description: " Maximum initial symmetrical short-circuit currents (Ik\" max)\
\ in A (Ik\" = Sk\"/(SQRT(3) Un)). Used for short circuit data exchange according\
\ to IEC 60909.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ExternalNetworkInjection.maxInitialSymShCCurrent
multivalued: false
domain_of:
- ExternalNetworkInjection
range: CurrentFlow
required: false
max_p:
name: max_p
description: Maximum active power of the injection.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:ExternalNetworkInjection.maxP
multivalued: false
domain_of:
- EquivalentInjection
- PowerElectronicsUnit
- ACDCConverter
- FrequencyConverter
- ExternalNetworkInjection
- GeneratorTypeAsset
range: ActivePower
required: false
max_q:
name: max_q
description: "Maximum reactive power limit. It is used for modelling of infeed\
\ for load flow exchange and not for short circuit modelling.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:ExternalNetworkInjection.maxQ
multivalued: false
domain_of:
- SynchronousMachine
- EquivalentInjection
- PowerElectronicsConnection
- ExternalNetworkInjection
- GeneratorTypeAsset
range: ReactivePower
required: false
max_r_to_x_ratio:
name: max_r_to_x_ratio
description: "Maximum ratio of positive sequence resistance of Network Feeder\
\ to its positive sequence reactance (R(1)/X(1) max). Used for short circuit\
\ data exchange according to IEC 60909.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ExternalNetworkInjection.maxR1ToX1Ratio
multivalued: false
domain_of:
- ExternalNetworkInjection
range: float
required: false
max_z_to_z_ratio:
name: max_z_to_z_ratio
description: "Maximum ratio of zero sequence impedance to its positive sequence\
\ impedance (Z(0)/Z(1) max). Used for short circuit data exchange according\
\ to IEC 60909.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ExternalNetworkInjection.maxZ0ToZ1Ratio
multivalued: false
domain_of:
- ExternalNetworkInjection
range: float
required: false
min_initial_sym_sh_ccurrent:
name: min_initial_sym_sh_ccurrent
description: "Minimum initial symmetrical short-circuit currents (Ik\" min) in\
\ A (Ik\" = Sk\"/(SQRT(3) Un)). Used for short circuit data exchange according\
\ to IEC 60909.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ExternalNetworkInjection.minInitialSymShCCurrent
multivalued: false
domain_of:
- ExternalNetworkInjection
range: CurrentFlow
required: false
min_p:
name: min_p
description: Minimum active power of the injection.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:ExternalNetworkInjection.minP
multivalued: false
domain_of:
- EquivalentInjection
- PowerElectronicsUnit
- ACDCConverter
- FrequencyConverter
- ExternalNetworkInjection
- GeneratorTypeAsset
range: ActivePower
required: false
min_q:
name: min_q
description: "Minimum reactive power limit. It is used for modelling of infeed\
\ for load flow exchange and not for short circuit modelling.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:ExternalNetworkInjection.minQ
multivalued: false
domain_of:
- SynchronousMachine
- EquivalentInjection
- PowerElectronicsConnection
- ExternalNetworkInjection
- GeneratorTypeAsset
range: ReactivePower
required: false
min_r_to_x_ratio:
name: min_r_to_x_ratio
description: "Minimum ratio of positive sequence resistance of Network Feeder\
\ to its positive sequence reactance (R(1)/X(1) min). Used for short circuit\
\ data exchange according to IEC 60909.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ExternalNetworkInjection.minR1ToX1Ratio
multivalued: false
domain_of:
- ExternalNetworkInjection
range: float
required: false
min_z_to_z_ratio:
name: min_z_to_z_ratio
description: "Minimum ratio of zero sequence impedance to its positive sequence\
\ impedance (Z(0)/Z(1) min). Used for short circuit data exchange according\
\ to IEC 60909.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ExternalNetworkInjection.minZ0ToZ1Ratio
multivalued: false
domain_of:
- ExternalNetworkInjection
range: float
required: false
p:
name: p
description: "Active power injection. Load sign convention is used, i.e. positive\
\ sign means flow out from a node.\r\nStarting value for steady state solutions."
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:ExternalNetworkInjection.p
multivalued: false
domain_of:
- EnergyGroup
- BlockDispatchOrder
- SvPowerFlow
- RotatingMachine
- EquivalentInjection
- PowerElectronicsConnection
- PowerElectronicsConnectionPhase
- ACDCConverter
- EnergyConsumerPhase
- EnergyConsumer
- ExternalNetworkInjection
- GovHydroPID2
- UnderexcLimIEEE2
- UnderexcLim2Simplified
range: ActivePower
required: false
q:
name: q
description: "Reactive power injection. Load sign convention is used, i.e. positive\
\ sign means flow out from a node.\r\nStarting value for steady state solutions."
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:ExternalNetworkInjection.q
multivalued: false
domain_of:
- SvPowerFlow
- RotatingMachine
- EquivalentInjection
- PowerElectronicsConnection
- PowerElectronicsConnectionPhase
- ACDCConverter
- EnergyConsumerPhase
- EnergyConsumer
- StaticVarCompensator
- ExternalNetworkInjection
- UnderexcLimIEEE2
- UnderexcLim2Simplified
range: ReactivePower
required: false
reference_priority:
name: reference_priority
description: "Priority of unit for use as powerflow voltage phase angle reference\
\ bus selection. 0 = don t care (default) 1 = highest priority. 2 is less than\
\ 1 and so on.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:ExternalNetworkInjection.referencePriority
multivalued: false
domain_of:
- SynchronousMachine
- ExternalNetworkInjection
range: integer
required: false
voltage_factor:
name: voltage_factor
description: "Voltage factor in pu, which was used to calculate short-circuit\
\ current Ik\" and power Sk\". Used only if short circuit calculations are\
\ done according to superposition method.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ExternalNetworkInjection.voltageFactor
multivalued: false
domain_of:
- ExternalNetworkInjection
range: PU
required: false
class_uri: cim:ExternalNetworkInjection
Induced
name: ExternalNetworkInjection
description: This class represents the external network and it is used for IEC 60909
calculations.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
is_a: RegulatingCondEq
attributes:
governor_scd:
name: governor_scd
description: Power Frequency Bias. This is the change in power injection divided
by the change in frequency and negated. A positive value of the power frequency
bias provides additional power injection upon a drop in frequency.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:ExternalNetworkInjection.governorSCD
multivalued: false
alias: governor_scd
owner: ExternalNetworkInjection
domain_of:
- GeneratingUnit
- ExternalNetworkInjection
range: ActivePowerPerFrequency
required: false
ik_second:
name: ik_second
description: Indicates whether initial symmetrical short-circuit current and power
have been calculated according to IEC (Ik"). Used only if short circuit calculations
are done according to superposition method.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ExternalNetworkInjection.ikSecond
multivalued: false
alias: ik_second
owner: ExternalNetworkInjection
domain_of:
- ExternalNetworkInjection
range: boolean
required: false
max_initial_sym_sh_ccurrent:
name: max_initial_sym_sh_ccurrent
description: " Maximum initial symmetrical short-circuit currents (Ik\" max)\
\ in A (Ik\" = Sk\"/(SQRT(3) Un)). Used for short circuit data exchange according\
\ to IEC 60909.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ExternalNetworkInjection.maxInitialSymShCCurrent
multivalued: false
alias: max_initial_sym_sh_ccurrent
owner: ExternalNetworkInjection
domain_of:
- ExternalNetworkInjection
range: CurrentFlow
required: false
max_p:
name: max_p
description: Maximum active power of the injection.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:ExternalNetworkInjection.maxP
multivalued: false
alias: max_p
owner: ExternalNetworkInjection
domain_of:
- EquivalentInjection
- PowerElectronicsUnit
- ACDCConverter
- FrequencyConverter
- ExternalNetworkInjection
- GeneratorTypeAsset
range: ActivePower
required: false
max_q:
name: max_q
description: "Maximum reactive power limit. It is used for modelling of infeed\
\ for load flow exchange and not for short circuit modelling.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:ExternalNetworkInjection.maxQ
multivalued: false
alias: max_q
owner: ExternalNetworkInjection
domain_of:
- SynchronousMachine
- EquivalentInjection
- PowerElectronicsConnection
- ExternalNetworkInjection
- GeneratorTypeAsset
range: ReactivePower
required: false
max_r_to_x_ratio:
name: max_r_to_x_ratio
description: "Maximum ratio of positive sequence resistance of Network Feeder\
\ to its positive sequence reactance (R(1)/X(1) max). Used for short circuit\
\ data exchange according to IEC 60909.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ExternalNetworkInjection.maxR1ToX1Ratio
multivalued: false
alias: max_r_to_x_ratio
owner: ExternalNetworkInjection
domain_of:
- ExternalNetworkInjection
range: float
required: false
max_z_to_z_ratio:
name: max_z_to_z_ratio
description: "Maximum ratio of zero sequence impedance to its positive sequence\
\ impedance (Z(0)/Z(1) max). Used for short circuit data exchange according\
\ to IEC 60909.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ExternalNetworkInjection.maxZ0ToZ1Ratio
multivalued: false
alias: max_z_to_z_ratio
owner: ExternalNetworkInjection
domain_of:
- ExternalNetworkInjection
range: float
required: false
min_initial_sym_sh_ccurrent:
name: min_initial_sym_sh_ccurrent
description: "Minimum initial symmetrical short-circuit currents (Ik\" min) in\
\ A (Ik\" = Sk\"/(SQRT(3) Un)). Used for short circuit data exchange according\
\ to IEC 60909.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ExternalNetworkInjection.minInitialSymShCCurrent
multivalued: false
alias: min_initial_sym_sh_ccurrent
owner: ExternalNetworkInjection
domain_of:
- ExternalNetworkInjection
range: CurrentFlow
required: false
min_p:
name: min_p
description: Minimum active power of the injection.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:ExternalNetworkInjection.minP
multivalued: false
alias: min_p
owner: ExternalNetworkInjection
domain_of:
- EquivalentInjection
- PowerElectronicsUnit
- ACDCConverter
- FrequencyConverter
- ExternalNetworkInjection
- GeneratorTypeAsset
range: ActivePower
required: false
min_q:
name: min_q
description: "Minimum reactive power limit. It is used for modelling of infeed\
\ for load flow exchange and not for short circuit modelling.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:ExternalNetworkInjection.minQ
multivalued: false
alias: min_q
owner: ExternalNetworkInjection
domain_of:
- SynchronousMachine
- EquivalentInjection
- PowerElectronicsConnection
- ExternalNetworkInjection
- GeneratorTypeAsset
range: ReactivePower
required: false
min_r_to_x_ratio:
name: min_r_to_x_ratio
description: "Minimum ratio of positive sequence resistance of Network Feeder\
\ to its positive sequence reactance (R(1)/X(1) min). Used for short circuit\
\ data exchange according to IEC 60909.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ExternalNetworkInjection.minR1ToX1Ratio
multivalued: false
alias: min_r_to_x_ratio
owner: ExternalNetworkInjection
domain_of:
- ExternalNetworkInjection
range: float
required: false
min_z_to_z_ratio:
name: min_z_to_z_ratio
description: "Minimum ratio of zero sequence impedance to its positive sequence\
\ impedance (Z(0)/Z(1) min). Used for short circuit data exchange according\
\ to IEC 60909.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ExternalNetworkInjection.minZ0ToZ1Ratio
multivalued: false
alias: min_z_to_z_ratio
owner: ExternalNetworkInjection
domain_of:
- ExternalNetworkInjection
range: float
required: false
p:
name: p
description: "Active power injection. Load sign convention is used, i.e. positive\
\ sign means flow out from a node.\r\nStarting value for steady state solutions."
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:ExternalNetworkInjection.p
multivalued: false
alias: p
owner: ExternalNetworkInjection
domain_of:
- EnergyGroup
- BlockDispatchOrder
- SvPowerFlow
- RotatingMachine
- EquivalentInjection
- PowerElectronicsConnection
- PowerElectronicsConnectionPhase
- ACDCConverter
- EnergyConsumerPhase
- EnergyConsumer
- ExternalNetworkInjection
- GovHydroPID2
- UnderexcLimIEEE2
- UnderexcLim2Simplified
range: ActivePower
required: false
q:
name: q
description: "Reactive power injection. Load sign convention is used, i.e. positive\
\ sign means flow out from a node.\r\nStarting value for steady state solutions."
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:ExternalNetworkInjection.q
multivalued: false
alias: q
owner: ExternalNetworkInjection
domain_of:
- SvPowerFlow
- RotatingMachine
- EquivalentInjection
- PowerElectronicsConnection
- PowerElectronicsConnectionPhase
- ACDCConverter
- EnergyConsumerPhase
- EnergyConsumer
- StaticVarCompensator
- ExternalNetworkInjection
- UnderexcLimIEEE2
- UnderexcLim2Simplified
range: ReactivePower
required: false
reference_priority:
name: reference_priority
description: "Priority of unit for use as powerflow voltage phase angle reference\
\ bus selection. 0 = don t care (default) 1 = highest priority. 2 is less than\
\ 1 and so on.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:ExternalNetworkInjection.referencePriority
multivalued: false
alias: reference_priority
owner: ExternalNetworkInjection
domain_of:
- SynchronousMachine
- ExternalNetworkInjection
range: integer
required: false
voltage_factor:
name: voltage_factor
description: "Voltage factor in pu, which was used to calculate short-circuit\
\ current Ik\" and power Sk\". Used only if short circuit calculations are\
\ done according to superposition method.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ExternalNetworkInjection.voltageFactor
multivalued: false
alias: voltage_factor
owner: ExternalNetworkInjection
domain_of:
- ExternalNetworkInjection
range: PU
required: false
control_enabled:
name: control_enabled
description: Specifies the regulation status of the equipment. True is regulating,
false is not regulating.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:RegulatingCondEq.controlEnabled
multivalued: false
alias: control_enabled
owner: ExternalNetworkInjection
domain_of:
- RegulatingCondEq
- TapChanger
range: boolean
required: false
regulating_control:
name: regulating_control
description: The regulating control scheme in which this equipment participates.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:RegulatingCondEq.RegulatingControl
multivalued: false
alias: regulating_control
owner: ExternalNetworkInjection
domain_of:
- Terminal
- RegulatingCondEq
- RegulationSchedule
- ProtectiveActionRegulation
range: RegulatingControl
required: false
energy_component:
name: energy_component
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:EnergyConnection.EnergyComponent
multivalued: true
alias: energy_component
owner: ExternalNetworkInjection
domain_of:
- EnergyGroup
- EnergyConnection
range: EnergyComponent
required: false
protective_action_adjustment:
name: protective_action_adjustment
description: 'The operating condition to the Conducting Equipment is changed when
protective action adjustment is activated. For ShuntCompensator or other conducting
equipment that operates on discrete values (integer), the values given in float
will be rounded. '
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:ConductingEquipment.ProtectiveActionAdjustment
multivalued: true
alias: protective_action_adjustment
owner: ExternalNetworkInjection
domain_of:
- Measurement
- ConductingEquipment
- DCConductingEquipment
range: ProtectiveActionAdjustment
required: false
sv_status:
name: sv_status
description: The status state variable associated with this conducting equipment.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ConductingEquipment.SvStatus
multivalued: true
alias: sv_status
owner: ExternalNetworkInjection
domain_of:
- ConductingEquipment
range: SvStatus
required: false
protection_equipments:
name: protection_equipments
description: 'Protection equipment used to protect specific conducting equipment. '
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ConductingEquipment.ProtectionEquipments
multivalued: true
alias: protection_equipments
owner: ExternalNetworkInjection
domain_of:
- ConductingEquipment
range: ProtectionEquipment
required: false
base_voltage:
name: base_voltage
description: Base voltage of this conducting equipment. Use only when there is
no voltage level container used and only one base voltage applies. For example,
not used for transformers.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:ConductingEquipment.BaseVoltage
multivalued: false
alias: base_voltage
owner: ExternalNetworkInjection
domain_of:
- TopologicalNode
- TransformerEnd
- ConductingEquipment
- VoltageLevel
- AssetDeployment
range: BaseVoltage
required: false
terminals:
name: terminals
description: Conducting equipment have terminals that may be connected to other
conducting equipment terminals via connectivity nodes or topological nodes.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:ConductingEquipment.Terminals
multivalued: true
alias: terminals
owner: ExternalNetworkInjection
domain_of:
- ConnectivityNode
- ConductingEquipment
range: Terminal
required: false
jumping_action:
name: jumping_action
description: Jumper action involving jumping operation on this conducting equipment.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ConductingEquipment.JumpingAction
multivalued: false
alias: jumping_action
owner: ExternalNetworkInjection
domain_of:
- ConductingEquipment
range: JumperAction
required: false
grounding_action:
name: grounding_action
description: Action involving grounding operation on this conducting equipment.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ConductingEquipment.GroundingAction
multivalued: false
alias: grounding_action
owner: ExternalNetworkInjection
domain_of:
- ConductingEquipment
range: GroundAction
required: false
outage:
name: outage
description: The outage that is isolated by the outage isolation equipment.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:ConductingEquipment.Outage
multivalued: false
alias: outage
owner: ExternalNetworkInjection
domain_of:
- Incident
- SwitchingPlan
- UsagePoint
- ConductingEquipment
- Crew
- EstimatedRestorationTime
- OutageArea
- Fault
range: Outage
required: false
aggregate:
name: aggregate
description: "The aggregate flag provides an alternative way of representing an\
\ aggregated (equivalent) element. It is applicable in cases when the dedicated\
\ classes for equivalent equipment do not have all of the attributes necessary\
\ to represent the required level of detail. In case the flag is set to “true”\
\ the single instance of equipment represents multiple pieces of equipment that\
\ have been modelled together as an aggregate equivalent obtained by a network\
\ reduction procedure. Examples would be power transformers or synchronous machines\
\ operating in parallel modelled as a single aggregate power transformer or\
\ aggregate synchronous machine. \r\nThe attribute is not used for EquivalentBranch,\
\ EquivalentShunt and EquivalentInjection."
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.aggregate
multivalued: false
alias: aggregate
owner: ExternalNetworkInjection
domain_of:
- Equipment
- ReadingType
range: boolean
required: false
in_service:
name: in_service
description: Specifies the availability of the equipment. True means the equipment
is available for topology processing, which determines if the equipment is energized
or not. False means that the equipment is treated by network applications as
if it is not in the model.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.inService
multivalued: false
alias: in_service
owner: ExternalNetworkInjection
domain_of:
- Equipment
- SvStatus
- ProtectiveActionEquipment
range: boolean
required: false
network_analysis_enabled:
name: network_analysis_enabled
description: The equipment is enabled to participate in network analysis. If
unspecified, the value is assumed to be true.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.networkAnalysisEnabled
multivalued: false
alias: network_analysis_enabled
owner: ExternalNetworkInjection
domain_of:
- Equipment
range: boolean
required: false
normally_in_service:
name: normally_in_service
description: Specifies the availability of the equipment under normal operating
conditions. True means the equipment is available for topology processing, which
determines if the equipment is energized or not. False means that the equipment
is treated by network applications as if it is not in the model.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.normallyInService
multivalued: false
alias: normally_in_service
owner: ExternalNetworkInjection
domain_of:
- Equipment
range: boolean
required: false
weather_station:
name: weather_station
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.WeatherStation
multivalued: true
alias: weather_station
owner: ExternalNetworkInjection
domain_of:
- Equipment
range: WeatherStation
required: false
operational_limit_set:
name: operational_limit_set
description: The operational limit sets associated with this equipment.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:Equipment.OperationalLimitSet
multivalued: true
alias: operational_limit_set
owner: ExternalNetworkInjection
domain_of:
- ACDCTerminal
- OperationalLimit
- Equipment
range: OperationalLimitSet
required: false
contingency_equipment:
name: contingency_equipment
description: The contingency equipments in which this equipment participates.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.ContingencyEquipment
multivalued: true
alias: contingency_equipment
owner: ExternalNetworkInjection
domain_of:
- Equipment
range: ContingencyEquipment
required: false
equipment_container:
name: equipment_container
description: Container of this equipment.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.EquipmentContainer
multivalued: false
alias: equipment_container
owner: ExternalNetworkInjection
domain_of:
- Equipment
range: EquipmentContainer
required: false
faults:
name: faults
description: All faults on this equipment.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.Faults
multivalued: true
alias: faults
owner: ExternalNetworkInjection
domain_of:
- Equipment
- Outage
- FaultCauseType
range: Fault
required: false
limit_dependency_model:
name: limit_dependency_model
description: Limit dependencymodels organized under this equipment as a means
for organizing the model in a tree view.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:Equipment.LimitDependencyModel
multivalued: true
alias: limit_dependency_model
owner: ExternalNetworkInjection
domain_of:
- OperationalLimit
- Equipment
range: LimitDependency
required: false
eqiupment_limit_series_component:
name: eqiupment_limit_series_component
description: Equipment limit series calculation component to which this equipment
contributes.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.EqiupmentLimitSeriesComponent
multivalued: true
alias: eqiupment_limit_series_component
owner: ExternalNetworkInjection
domain_of:
- Equipment
range: EquipmentLimitSeriesComponent
required: false
protective_action_equipment:
name: protective_action_equipment
description: Protective action is controlling equipment. This can be direct signals
from the control center, or emulation of action done by protection equipment.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.ProtectiveActionEquipment
multivalued: true
alias: protective_action_equipment
owner: ExternalNetworkInjection
domain_of:
- Equipment
range: ProtectiveActionEquipment
required: false
pin_equipment:
name: pin_equipment
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.PinEquipment
multivalued: true
alias: pin_equipment
owner: ExternalNetworkInjection
domain_of:
- Equipment
range: PinEquipment
required: false
equipment_unavailability_schedule:
name: equipment_unavailability_schedule
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.EquipmentUnavailabilitySchedule
multivalued: true
alias: equipment_unavailability_schedule
owner: ExternalNetworkInjection
domain_of:
- Equipment
- UnavailabilitySwitchAction
- UnavailablitySchedule
range: EquipmentUnavailabilitySchedule
required: false
additional_equipment_container:
name: additional_equipment_container
description: Additional equipment container beyond the primary equipment container. The
equipment is contained in another equipment container, but also grouped with
this equipment container.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.AdditionalEquipmentContainer
multivalued: true
alias: additional_equipment_container
owner: ExternalNetworkInjection
domain_of:
- Equipment
range: EquipmentContainer
required: false
usage_points:
name: usage_points
description: All usage points connected to the electrical grid through this equipment.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.UsagePoints
multivalued: true
alias: usage_points
owner: ExternalNetworkInjection
domain_of:
- Equipment
- CustomerAgreement
- ServiceCategory
- PricingStructure
- EndDeviceControl
- UsagePointGroup
- ServiceLocation
- MetrologyRequirement
- ServiceSupplier
- UsagePointLocation
range: UsagePoint
required: false
outages:
name: outages
description: All outages in which this equipment is involved.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.Outages
multivalued: true
alias: outages
owner: ExternalNetworkInjection
domain_of:
- Equipment
range: Outage
required: false
operational_restrictions:
name: operational_restrictions
description: All operational restrictions for this equipment.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.OperationalRestrictions
multivalued: true
alias: operational_restrictions
owner: ExternalNetworkInjection
domain_of:
- Equipment
- ProductAssetModel
range: OperationalRestriction
required: false
controls:
name: controls
description: The controller outputs used to actually govern a regulating device,
e.g. the magnetization of a synchronous machine or capacitor bank breaker actuator.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.Controls
multivalued: true
alias: controls
owner: ExternalNetworkInjection
domain_of:
- PowerSystemResource
- HostControlArea
range: Control
required: false
measurements:
name: measurements
description: The measurements associated with this power system resource.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.Measurements
multivalued: true
alias: measurements
owner: ExternalNetworkInjection
domain_of:
- PowerSystemResource
- ACDCTerminal
- Asset
- Location
- Procedure
- AnalogLimitSet
- AccumulatorLimitSet
range: Measurement
required: false
psrtype:
name: psrtype
description: Custom classification for this power system resource.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.PSRType
multivalued: false
alias: psrtype
owner: ExternalNetworkInjection
domain_of:
- PowerSystemResource
range: PSRType
required: false
configuration_event:
name: configuration_event
description: All configuration events created for this Power System resource.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.ConfigurationEvent
multivalued: true
alias: configuration_event
owner: ExternalNetworkInjection
domain_of:
- PowerSystemResource
- FaultCauseType
range: ConfigurationEvent
required: false
reporting_group:
name: reporting_group
description: Reporting groups to which this power system resource belongs.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.ReportingGroup
multivalued: true
alias: reporting_group
owner: ExternalNetworkInjection
domain_of:
- PowerSystemResource
- BusNameMarker
- TopologicalNode
- ReportingSuperGroup
range: ReportingGroup
required: false
operating_share:
name: operating_share
description: The operating shares of this power system resource.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.OperatingShare
multivalued: true
alias: operating_share
owner: ExternalNetworkInjection
domain_of:
- PowerSystemResource
- OperatingParticipant
range: OperatingShare
required: false
asset_datasheet:
name: asset_datasheet
description: Datasheet information for this power system resource.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.AssetDatasheet
multivalued: false
alias: asset_datasheet
owner: ExternalNetworkInjection
domain_of:
- PowerSystemResource
range: AssetInfo
required: false
verification_action:
name: verification_action
description: The verification action that is performed on the power system resource
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.VerificationAction
multivalued: true
alias: verification_action
owner: ExternalNetworkInjection
domain_of:
- PowerSystemResource
range: VerificationAction
required: false
clearances:
name: clearances
description: All clearances applicable to this power system resource.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.Clearances
multivalued: true
alias: clearances
owner: ExternalNetworkInjection
domain_of:
- PowerSystemResource
range: ClearanceDocument
required: false
generic_action:
name: generic_action
description: The generic action that is performed on the power system resource
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.GenericAction
multivalued: true
alias: generic_action
owner: ExternalNetworkInjection
domain_of:
- PowerSystemResource
range: GenericAction
required: false
psrevents:
name: psrevents
description: All events associated with this power system resource.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.PSREvents
multivalued: true
alias: psrevents
owner: ExternalNetworkInjection
domain_of:
- PowerSystemResource
range: PSREvent
required: false
assets:
name: assets
description: All assets represented by this power system resource. For example,
multiple conductor assets are electrically modelled as a single AC line segment.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.Assets
multivalued: true
alias: assets
owner: ExternalNetworkInjection
domain_of:
- PowerSystemResource
- AssetInfo
- Location
- WorkTask
- ErpRecDelvLineItem
- AssetContainer
- ActivityRecord
- Procedure
- ReliabilityInfo
- AssetPropertyCurve
- AssetOrganisationRole
- ScheduledEvent
range: Asset
required: false
location:
name: location
description: Location of this power system resource.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.Location
multivalued: false
alias: location
owner: ExternalNetworkInjection
domain_of:
- PowerSystemResource
- Asset
- Incident
- SwitchingOrder
- TroubleOrder
- Crew
- Fault
- PointOfSale
- TroubleTicket
- OutageOrder
- EnvironmentalMonitoringStation
- EnvironmentalLocationType
- PositionPoint
- FailureEvent
range: Location
required: false
operational_tags:
name: operational_tags
description: All operational tags placed on this power system resource.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.OperationalTags
multivalued: true
alias: operational_tags
owner: ExternalNetworkInjection
domain_of:
- PowerSystemResource
- Asset
range: OperationalTag
required: false
alias_name:
name: alias_name
description: "The aliasName is free text human readable name of the object alternative\
\ to IdentifiedObject.name. It may be non unique and may not correlate to a\
\ naming hierarchy.\r\nThe attribute aliasName is retained because of backwards\
\ compatibility between CIM relases. It is however recommended to replace aliasName\
\ with the Name class as aliasName is planned for retirement at a future time.\r\
\n\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.aliasName
multivalued: false
alias: alias_name
owner: ExternalNetworkInjection
domain_of:
- IdentifiedObject
range: string
required: false
description:
name: description
description: The description is a free human readable text describing or naming
the object. It may be non unique and may not correlate to a naming hierarchy.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.description
multivalued: false
alias: description
owner: ExternalNetworkInjection
domain_of:
- IdentifiedObject
- NameType
- NameTypeAuthority
- DataSet
- SwitchingStepGroup
- AreaReserveSpec
range: string
required: false
m_rid:
name: m_rid
description: "Master resource identifier issued by a model authority. The mRID\
\ is unique within an exchange context. Global uniqueness is easily achieved\
\ by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is\
\ strongly recommended.\r\nFor CIMXML data files in RDF syntax conforming to\
\ IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify\
\ CIM object elements."
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.mRID
multivalued: false
alias: m_rid
owner: ExternalNetworkInjection
domain_of:
- IdentifiedObject
- DataSet
range: string
required: false
diagram_objects:
name: diagram_objects
description: The diagram objects that are associated with the domain object.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.DiagramObjects
multivalued: true
alias: diagram_objects
owner: ExternalNetworkInjection
domain_of:
- IdentifiedObject
range: DiagramObject
required: false
instance_set:
name: instance_set
description: Dataset containing the data objects.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.InstanceSet
multivalued: false
alias: instance_set
owner: ExternalNetworkInjection
domain_of:
- IdentifiedObject
range: InstanceSet
required: true
names:
name: names
description: All names of this identified object.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.Names
multivalued: true
alias: names
owner: ExternalNetworkInjection
domain_of:
- IdentifiedObject
- NameType
range: Name
required: false
properties_cimdata_object:
name: properties_cimdata_object
description: The single CIM data object in the appropriate dataset context.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.PropertiesCIMDataObject
multivalued: false
alias: properties_cimdata_object
owner: ExternalNetworkInjection
domain_of:
- IdentifiedObject
range: ChangeSetMember
required: false
targeting_cimdata_object:
name: targeting_cimdata_object
description: Data objects registered.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.TargetingCIMDataObject
multivalued: true
alias: targeting_cimdata_object
owner: ExternalNetworkInjection
domain_of:
- IdentifiedObject
range: ChangeSetMember
required: false
class_uri: cim:ExternalNetworkInjection