Skip to content

Class: EnergySource

A generic equivalent for an energy supplier on a transmission or distribution voltage level.

URI: cim:EnergySource

 classDiagram
    class EnergySource
      EnergyConnection <|-- EnergySource

      EnergySource : active_power

          EnergySource --> ActivePower : active_power

      EnergySource : additional_equipment_container

          EnergySource --> EquipmentContainer : additional_equipment_container

      EnergySource : aggregate

      EnergySource : alias_name

      EnergySource : asset_datasheet

          EnergySource --> AssetInfo : asset_datasheet

      EnergySource : assets

          EnergySource --> Asset : assets

      EnergySource : base_voltage

          EnergySource --> BaseVoltage : base_voltage

      EnergySource : clearances

          EnergySource --> ClearanceDocument : clearances

      EnergySource : configuration_event

          EnergySource --> ConfigurationEvent : configuration_event

      EnergySource : contingency_equipment

          EnergySource --> ContingencyEquipment : contingency_equipment

      EnergySource : controls

          EnergySource --> Control : controls

      EnergySource : description

      EnergySource : diagram_objects

          EnergySource --> DiagramObject : diagram_objects

      EnergySource : energy_component

          EnergySource --> EnergyComponent : energy_component

      EnergySource : energy_scheduling_type

          EnergySource --> EnergySchedulingType : energy_scheduling_type

      EnergySource : energy_source_action

          EnergySource --> EnergySourceAction : energy_source_action

      EnergySource : energy_source_phase

          EnergySource --> EnergySourcePhase : energy_source_phase

      EnergySource : eqiupment_limit_series_component

          EnergySource --> EquipmentLimitSeriesComponent : eqiupment_limit_series_component

      EnergySource : equipment_container

          EnergySource --> EquipmentContainer : equipment_container

      EnergySource : equipment_unavailability_schedule

          EnergySource --> EquipmentUnavailabilitySchedule : equipment_unavailability_schedule

      EnergySource : faults

          EnergySource --> Fault : faults

      EnergySource : generic_action

          EnergySource --> GenericAction : generic_action

      EnergySource : grounding_action

          EnergySource --> GroundAction : grounding_action

      EnergySource : in_service

      EnergySource : instance_set

          EnergySource --> InstanceSet : instance_set

      EnergySource : jumping_action

          EnergySource --> JumperAction : jumping_action

      EnergySource : limit_dependency_model

          EnergySource --> LimitDependency : limit_dependency_model

      EnergySource : location

          EnergySource --> Location : location

      EnergySource : m_rid

      EnergySource : measurements

          EnergySource --> Measurement : measurements

      EnergySource : names

          EnergySource --> Name : names

      EnergySource : network_analysis_enabled

      EnergySource : nominal_voltage

          EnergySource --> Voltage : nominal_voltage

      EnergySource : normally_in_service

      EnergySource : operating_share

          EnergySource --> OperatingShare : operating_share

      EnergySource : operational_limit_set

          EnergySource --> OperationalLimitSet : operational_limit_set

      EnergySource : operational_restrictions

          EnergySource --> OperationalRestriction : operational_restrictions

      EnergySource : operational_tags

          EnergySource --> OperationalTag : operational_tags

      EnergySource : outage

          EnergySource --> Outage : outage

      EnergySource : outages

          EnergySource --> Outage : outages

      EnergySource : p_max

          EnergySource --> ActivePower : p_max

      EnergySource : p_min

          EnergySource --> ActivePower : p_min

      EnergySource : pin_equipment

          EnergySource --> PinEquipment : pin_equipment

      EnergySource : properties_cimdata_object

          EnergySource --> ChangeSetMember : properties_cimdata_object

      EnergySource : protection_equipments

          EnergySource --> ProtectionEquipment : protection_equipments

      EnergySource : protective_action_adjustment

          EnergySource --> ProtectiveActionAdjustment : protective_action_adjustment

      EnergySource : protective_action_equipment

          EnergySource --> ProtectiveActionEquipment : protective_action_equipment

      EnergySource : psrevents

          EnergySource --> PSREvent : psrevents

      EnergySource : psrtype

          EnergySource --> PSRType : psrtype

      EnergySource : r

          EnergySource --> Resistance : r

      EnergySource : reactive_power

          EnergySource --> ReactivePower : reactive_power

      EnergySource : reporting_group

          EnergySource --> ReportingGroup : reporting_group

      EnergySource : rn

          EnergySource --> Resistance : rn

      EnergySource : sv_status

          EnergySource --> SvStatus : sv_status

      EnergySource : targeting_cimdata_object

          EnergySource --> ChangeSetMember : targeting_cimdata_object

      EnergySource : terminals

          EnergySource --> Terminal : terminals

      EnergySource : usage_points

          EnergySource --> UsagePoint : usage_points

      EnergySource : verification_action

          EnergySource --> VerificationAction : verification_action

      EnergySource : voltage_angle

          EnergySource --> AngleRadians : voltage_angle

      EnergySource : voltage_magnitude

          EnergySource --> Voltage : voltage_magnitude

      EnergySource : weather_station

          EnergySource --> WeatherStation : weather_station

      EnergySource : x

          EnergySource --> Reactance : x

      EnergySource : xn

          EnergySource --> Reactance : xn

Inheritance

Slots

Name Cardinality and Range Description Inheritance
active_power 0..1
ActivePower
High voltage source active injection direct
nominal_voltage 0..1
Voltage
Phase-to-phase nominal voltage direct
p_max 0..1
ActivePower
This is the maximum active power that can be produced by the source direct
p_min 0..1
ActivePower
This is the minimum active power that can be produced by the source direct
r 0..1
Resistance
Zero sequence Thevenin resistance direct
reactive_power 0..1
ReactivePower
High voltage source reactive injection direct
rn 0..1
Resistance
Negative sequence Thevenin resistance direct
voltage_angle 0..1
AngleRadians
Phase angle of a-phase open circuit used when voltage characteristics need to... direct
voltage_magnitude 0..1
Voltage
Phase-to-phase open circuit voltage magnitude used when voltage characteristi... direct
x 0..1
Reactance
Zero sequence Thevenin reactance direct
xn 0..1
Reactance
Negative sequence Thevenin reactance direct
energy_scheduling_type 0..1
EnergySchedulingType
Energy Scheduling Type of an Energy Source direct
energy_source_phase 0..*
EnergySourcePhase
The individual phase information of the energy source direct
energy_source_action 0..1
EnergySourceAction
Action taken with this energy source direct
energy_component 0..*
EnergyComponent
EnergyConnection
protective_action_adjustment 0..*
ProtectiveActionAdjustment
The operating condition to the Conducting Equipment is changed when protectiv... ConductingEquipment
sv_status 0..*
SvStatus
The status state variable associated with this conducting equipment ConductingEquipment
protection_equipments 0..*
ProtectionEquipment
Protection equipment used to protect specific conducting equipment ConductingEquipment
base_voltage 0..1
BaseVoltage
Base voltage of this conducting equipment ConductingEquipment
terminals 0..*
Terminal
Conducting equipment have terminals that may be connected to other conducting... ConductingEquipment
jumping_action 0..1
JumperAction
Jumper action involving jumping operation on this conducting equipment ConductingEquipment
grounding_action 0..1
GroundAction
Action involving grounding operation on this conducting equipment ConductingEquipment
outage 0..1
Outage
The outage that is isolated by the outage isolation equipment ConductingEquipment
aggregate 0..1
Boolean
The aggregate flag provides an alternative way of representing an aggregated ... Equipment
in_service 0..1
Boolean
Specifies the availability of the equipment Equipment
network_analysis_enabled 0..1
Boolean
The equipment is enabled to participate in network analysis Equipment
normally_in_service 0..1
Boolean
Specifies the availability of the equipment under normal operating conditions Equipment
weather_station 0..*
WeatherStation
Equipment
operational_limit_set 0..*
OperationalLimitSet
The operational limit sets associated with this equipment Equipment
contingency_equipment 0..*
ContingencyEquipment
The contingency equipments in which this equipment participates Equipment
equipment_container 0..1
EquipmentContainer
Container of this equipment Equipment
faults 0..*
Fault
All faults on this equipment Equipment
limit_dependency_model 0..*
LimitDependency
Limit dependencymodels organized under this equipment as a means for organizi... Equipment
eqiupment_limit_series_component 0..*
EquipmentLimitSeriesComponent
Equipment limit series calculation component to which this equipment contribu... Equipment
protective_action_equipment 0..*
ProtectiveActionEquipment
Protective action is controlling equipment Equipment
pin_equipment 0..*
PinEquipment
Equipment
equipment_unavailability_schedule 0..*
EquipmentUnavailabilitySchedule
Equipment
additional_equipment_container 0..*
EquipmentContainer
Additional equipment container beyond the primary equipment container Equipment
usage_points 0..*
UsagePoint
All usage points connected to the electrical grid through this equipment Equipment
outages 0..*
Outage
All outages in which this equipment is involved Equipment
operational_restrictions 0..*
OperationalRestriction
All operational restrictions for this equipment Equipment
controls 0..*
Control
The controller outputs used to actually govern a regulating device, e PowerSystemResource
measurements 0..*
Measurement
The measurements associated with this power system resource PowerSystemResource
psrtype 0..1
PSRType
Custom classification for this power system resource PowerSystemResource
configuration_event 0..*
ConfigurationEvent
All configuration events created for this Power System resource PowerSystemResource
reporting_group 0..*
ReportingGroup
Reporting groups to which this power system resource belongs PowerSystemResource
operating_share 0..*
OperatingShare
The operating shares of this power system resource PowerSystemResource
asset_datasheet 0..1
AssetInfo
Datasheet information for this power system resource PowerSystemResource
verification_action 0..*
VerificationAction
The verification action that is performed on the power system resource PowerSystemResource
clearances 0..*
ClearanceDocument
All clearances applicable to this power system resource PowerSystemResource
generic_action 0..*
GenericAction
The generic action that is performed on the power system resource PowerSystemResource
psrevents 0..*
PSREvent
All events associated with this power system resource PowerSystemResource
assets 0..*
Asset
All assets represented by this power system resource PowerSystemResource
location 0..1
Location
Location of this power system resource PowerSystemResource
operational_tags 0..*
OperationalTag
All operational tags placed on this power system resource PowerSystemResource
alias_name 0..1
String
The aliasName is free text human readable name of the object alternative to I... IdentifiedObject
description 0..1
String
The description is a free human readable text describing or naming the object IdentifiedObject
m_rid 0..1
String
Master resource identifier issued by a model authority IdentifiedObject
diagram_objects 0..*
DiagramObject
The diagram objects that are associated with the domain object IdentifiedObject
instance_set 1..1
InstanceSet
Dataset containing the data objects IdentifiedObject
names 0..*
Name
All names of this identified object IdentifiedObject
properties_cimdata_object 0..1
ChangeSetMember
The single CIM data object in the appropriate dataset context IdentifiedObject
targeting_cimdata_object 0..*
ChangeSetMember
Data objects registered IdentifiedObject

Usages

used by used in type used
EnergySourcePhase energy_source range EnergySource
EnergySourceAction energy_source range EnergySource
EnergySchedulingType energy_source range EnergySource

Identifier and Mapping Information

Schema Source

  • from schema: https://cim.ucaiug.io/ns#TC57CIM

Mappings

Mapping Type Mapped Value
self cim:EnergySource
native cim:EnergySource

LinkML Source

Direct

name: EnergySource
description: A generic equivalent for an energy supplier on a transmission or distribution
  voltage level.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
is_a: EnergyConnection
attributes:
  active_power:
    name: active_power
    description: "High voltage source active injection. Load sign convention is used,\
      \ i.e. positive sign means flow out from a node.\r\nStarting value for steady\
      \ state solutions."
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:EnergySource.activePower
    multivalued: false
    domain_of:
    - EnergySource
    - ResponseMethod
    range: ActivePower
    required: false
  nominal_voltage:
    name: nominal_voltage
    description: Phase-to-phase nominal voltage.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:EnergySource.nominalVoltage
    multivalued: false
    domain_of:
    - BaseVoltage
    - EnergySource
    range: Voltage
    required: false
  p_max:
    name: p_max
    description: This is the maximum active power that can be produced by the source.
      Load sign convention is used, i.e. positive sign means flow out from a TopologicalNode
      (bus) into the conducting equipment.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:EnergySource.pMax
    multivalued: false
    domain_of:
    - EnergySource
    range: ActivePower
    required: false
  p_min:
    name: p_min
    description: This is the minimum active power that can be produced by the source.
      Load sign convention is used, i.e. positive sign means flow out from a TopologicalNode
      (bus) into the conducting equipment.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:EnergySource.pMin
    multivalued: false
    domain_of:
    - EnergySource
    range: ActivePower
    required: false
  r:
    name: r
    description: Zero sequence Thevenin resistance.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:EnergySource.r0
    multivalued: false
    domain_of:
    - MutualCoupling
    - TransformerMeshImpedance
    - TransformerEndInfo
    - PowerTransformerEnd
    - ACLineSegment
    - SynchronousMachine
    - EquivalentInjection
    - PowerElectronicsConnection
    - SeriesCompensator
    - TransformerStarImpedance
    - TapChangerTablePoint
    - PerLengthSequenceImpedance
    - PhaseImpedanceData
    - EarthFaultCompensator
    - EnergySource
    - EquivalentBranch
    - DCGround
    - GovCT1
    - GovCT2
    - GovGAST
    - GovGAST1
    - GovHydroDD
    - GovHydroPID
    - GovHydroR
    - GovSteam0
    - GovSteamFV2
    - ExcNI
    - UnderexcLimX2
    range: Resistance
    required: false
  reactive_power:
    name: reactive_power
    description: "High voltage source reactive injection. Load sign convention is\
      \ used, i.e. positive sign means flow out from a node.\r\nStarting value for\
      \ steady state solutions."
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:EnergySource.reactivePower
    multivalued: false
    domain_of:
    - EnergySource
    range: ReactivePower
    required: false
  rn:
    name: rn
    description: Negative sequence Thevenin resistance.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:EnergySource.rn
    multivalued: false
    domain_of:
    - PowerElectronicsConnection
    - EnergySource
    range: Resistance
    required: false
  voltage_angle:
    name: voltage_angle
    description: Phase angle of a-phase open circuit used when voltage characteristics
      need to be imposed at the node associated with the terminal of the energy source,
      such as when voltages and angles from the transmission level are used as input
      to the distribution network. The attribute shall be a positive value or zero.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:EnergySource.voltageAngle
    multivalued: false
    domain_of:
    - EnergySource
    range: AngleRadians
    required: false
  voltage_magnitude:
    name: voltage_magnitude
    description: Phase-to-phase open circuit voltage magnitude used when voltage characteristics
      need to be imposed at the node associated with the terminal of the energy source,
      such as when voltages and angles from the transmission level are used as input
      to the distribution network. The attribute shall be a positive value or zero.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:EnergySource.voltageMagnitude
    multivalued: false
    domain_of:
    - EnergySource
    range: Voltage
    required: false
  x:
    name: x
    description: Zero sequence Thevenin reactance.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:EnergySource.x0
    multivalued: false
    domain_of:
    - MutualCoupling
    - TransformerMeshImpedance
    - PowerTransformerEnd
    - ACLineSegment
    - SynchronousMachine
    - EquivalentInjection
    - PowerElectronicsConnection
    - SeriesCompensator
    - TransformerStarImpedance
    - TapChangerTablePoint
    - PerLengthSequenceImpedance
    - PhaseImpedanceData
    - GroundingImpedance
    - EnergySource
    - EquivalentBranch
    - GovGAST2
    range: Reactance
    required: false
  xn:
    name: xn
    description: Negative sequence Thevenin reactance.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:EnergySource.xn
    multivalued: false
    domain_of:
    - PowerElectronicsConnection
    - EnergySource
    range: Reactance
    required: false
  energy_scheduling_type:
    name: energy_scheduling_type
    description: Energy Scheduling Type of an Energy Source.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:EnergySource.EnergySchedulingType
    multivalued: false
    domain_of:
    - EnergySource
    range: EnergySchedulingType
    required: false
  energy_source_phase:
    name: energy_source_phase
    description: The individual phase information of the energy source.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:EnergySource.EnergySourcePhase
    multivalued: true
    domain_of:
    - EnergySource
    range: EnergySourcePhase
    required: false
  energy_source_action:
    name: energy_source_action
    description: Action taken with this energy source.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:EnergySource.EnergySourceAction
    multivalued: false
    domain_of:
    - EnergySource
    range: EnergySourceAction
    required: false
class_uri: cim:EnergySource

Induced

name: EnergySource
description: A generic equivalent for an energy supplier on a transmission or distribution
  voltage level.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
is_a: EnergyConnection
attributes:
  active_power:
    name: active_power
    description: "High voltage source active injection. Load sign convention is used,\
      \ i.e. positive sign means flow out from a node.\r\nStarting value for steady\
      \ state solutions."
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:EnergySource.activePower
    multivalued: false
    alias: active_power
    owner: EnergySource
    domain_of:
    - EnergySource
    - ResponseMethod
    range: ActivePower
    required: false
  nominal_voltage:
    name: nominal_voltage
    description: Phase-to-phase nominal voltage.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:EnergySource.nominalVoltage
    multivalued: false
    alias: nominal_voltage
    owner: EnergySource
    domain_of:
    - BaseVoltage
    - EnergySource
    range: Voltage
    required: false
  p_max:
    name: p_max
    description: This is the maximum active power that can be produced by the source.
      Load sign convention is used, i.e. positive sign means flow out from a TopologicalNode
      (bus) into the conducting equipment.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:EnergySource.pMax
    multivalued: false
    alias: p_max
    owner: EnergySource
    domain_of:
    - EnergySource
    range: ActivePower
    required: false
  p_min:
    name: p_min
    description: This is the minimum active power that can be produced by the source.
      Load sign convention is used, i.e. positive sign means flow out from a TopologicalNode
      (bus) into the conducting equipment.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:EnergySource.pMin
    multivalued: false
    alias: p_min
    owner: EnergySource
    domain_of:
    - EnergySource
    range: ActivePower
    required: false
  r:
    name: r
    description: Zero sequence Thevenin resistance.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:EnergySource.r0
    multivalued: false
    alias: r
    owner: EnergySource
    domain_of:
    - MutualCoupling
    - TransformerMeshImpedance
    - TransformerEndInfo
    - PowerTransformerEnd
    - ACLineSegment
    - SynchronousMachine
    - EquivalentInjection
    - PowerElectronicsConnection
    - SeriesCompensator
    - TransformerStarImpedance
    - TapChangerTablePoint
    - PerLengthSequenceImpedance
    - PhaseImpedanceData
    - EarthFaultCompensator
    - EnergySource
    - EquivalentBranch
    - DCGround
    - GovCT1
    - GovCT2
    - GovGAST
    - GovGAST1
    - GovHydroDD
    - GovHydroPID
    - GovHydroR
    - GovSteam0
    - GovSteamFV2
    - ExcNI
    - UnderexcLimX2
    range: Resistance
    required: false
  reactive_power:
    name: reactive_power
    description: "High voltage source reactive injection. Load sign convention is\
      \ used, i.e. positive sign means flow out from a node.\r\nStarting value for\
      \ steady state solutions."
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:EnergySource.reactivePower
    multivalued: false
    alias: reactive_power
    owner: EnergySource
    domain_of:
    - EnergySource
    range: ReactivePower
    required: false
  rn:
    name: rn
    description: Negative sequence Thevenin resistance.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:EnergySource.rn
    multivalued: false
    alias: rn
    owner: EnergySource
    domain_of:
    - PowerElectronicsConnection
    - EnergySource
    range: Resistance
    required: false
  voltage_angle:
    name: voltage_angle
    description: Phase angle of a-phase open circuit used when voltage characteristics
      need to be imposed at the node associated with the terminal of the energy source,
      such as when voltages and angles from the transmission level are used as input
      to the distribution network. The attribute shall be a positive value or zero.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:EnergySource.voltageAngle
    multivalued: false
    alias: voltage_angle
    owner: EnergySource
    domain_of:
    - EnergySource
    range: AngleRadians
    required: false
  voltage_magnitude:
    name: voltage_magnitude
    description: Phase-to-phase open circuit voltage magnitude used when voltage characteristics
      need to be imposed at the node associated with the terminal of the energy source,
      such as when voltages and angles from the transmission level are used as input
      to the distribution network. The attribute shall be a positive value or zero.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:EnergySource.voltageMagnitude
    multivalued: false
    alias: voltage_magnitude
    owner: EnergySource
    domain_of:
    - EnergySource
    range: Voltage
    required: false
  x:
    name: x
    description: Zero sequence Thevenin reactance.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:EnergySource.x0
    multivalued: false
    alias: x
    owner: EnergySource
    domain_of:
    - MutualCoupling
    - TransformerMeshImpedance
    - PowerTransformerEnd
    - ACLineSegment
    - SynchronousMachine
    - EquivalentInjection
    - PowerElectronicsConnection
    - SeriesCompensator
    - TransformerStarImpedance
    - TapChangerTablePoint
    - PerLengthSequenceImpedance
    - PhaseImpedanceData
    - GroundingImpedance
    - EnergySource
    - EquivalentBranch
    - GovGAST2
    range: Reactance
    required: false
  xn:
    name: xn
    description: Negative sequence Thevenin reactance.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:EnergySource.xn
    multivalued: false
    alias: xn
    owner: EnergySource
    domain_of:
    - PowerElectronicsConnection
    - EnergySource
    range: Reactance
    required: false
  energy_scheduling_type:
    name: energy_scheduling_type
    description: Energy Scheduling Type of an Energy Source.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:EnergySource.EnergySchedulingType
    multivalued: false
    alias: energy_scheduling_type
    owner: EnergySource
    domain_of:
    - EnergySource
    range: EnergySchedulingType
    required: false
  energy_source_phase:
    name: energy_source_phase
    description: The individual phase information of the energy source.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:EnergySource.EnergySourcePhase
    multivalued: true
    alias: energy_source_phase
    owner: EnergySource
    domain_of:
    - EnergySource
    range: EnergySourcePhase
    required: false
  energy_source_action:
    name: energy_source_action
    description: Action taken with this energy source.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:EnergySource.EnergySourceAction
    multivalued: false
    alias: energy_source_action
    owner: EnergySource
    domain_of:
    - EnergySource
    range: EnergySourceAction
    required: false
  energy_component:
    name: energy_component
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:EnergyConnection.EnergyComponent
    multivalued: true
    alias: energy_component
    owner: EnergySource
    domain_of:
    - EnergyGroup
    - EnergyConnection
    range: EnergyComponent
    required: false
  protective_action_adjustment:
    name: protective_action_adjustment
    description: 'The operating condition to the Conducting Equipment is changed when
      protective action adjustment is activated. For ShuntCompensator or other conducting
      equipment that operates on discrete values (integer), the values given in float
      will be rounded. '
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:ConductingEquipment.ProtectiveActionAdjustment
    multivalued: true
    alias: protective_action_adjustment
    owner: EnergySource
    domain_of:
    - Measurement
    - ConductingEquipment
    - DCConductingEquipment
    range: ProtectiveActionAdjustment
    required: false
  sv_status:
    name: sv_status
    description: The status state variable associated with this conducting equipment.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:ConductingEquipment.SvStatus
    multivalued: true
    alias: sv_status
    owner: EnergySource
    domain_of:
    - ConductingEquipment
    range: SvStatus
    required: false
  protection_equipments:
    name: protection_equipments
    description: 'Protection equipment  used to protect specific conducting equipment. '
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:ConductingEquipment.ProtectionEquipments
    multivalued: true
    alias: protection_equipments
    owner: EnergySource
    domain_of:
    - ConductingEquipment
    range: ProtectionEquipment
    required: false
  base_voltage:
    name: base_voltage
    description: Base voltage of this conducting equipment.  Use only when there is
      no voltage level container used and only one base voltage applies.  For example,
      not used for transformers.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:ConductingEquipment.BaseVoltage
    multivalued: false
    alias: base_voltage
    owner: EnergySource
    domain_of:
    - TopologicalNode
    - TransformerEnd
    - ConductingEquipment
    - VoltageLevel
    - AssetDeployment
    range: BaseVoltage
    required: false
  terminals:
    name: terminals
    description: Conducting equipment have terminals that may be connected to other
      conducting equipment terminals via connectivity nodes or topological nodes.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:ConductingEquipment.Terminals
    multivalued: true
    alias: terminals
    owner: EnergySource
    domain_of:
    - ConnectivityNode
    - ConductingEquipment
    range: Terminal
    required: false
  jumping_action:
    name: jumping_action
    description: Jumper action involving jumping operation on this conducting equipment.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:ConductingEquipment.JumpingAction
    multivalued: false
    alias: jumping_action
    owner: EnergySource
    domain_of:
    - ConductingEquipment
    range: JumperAction
    required: false
  grounding_action:
    name: grounding_action
    description: Action involving grounding operation on this conducting equipment.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:ConductingEquipment.GroundingAction
    multivalued: false
    alias: grounding_action
    owner: EnergySource
    domain_of:
    - ConductingEquipment
    range: GroundAction
    required: false
  outage:
    name: outage
    description: The outage that is isolated by the outage isolation equipment.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:ConductingEquipment.Outage
    multivalued: false
    alias: outage
    owner: EnergySource
    domain_of:
    - Incident
    - SwitchingPlan
    - UsagePoint
    - ConductingEquipment
    - Crew
    - EstimatedRestorationTime
    - OutageArea
    - Fault
    range: Outage
    required: false
  aggregate:
    name: aggregate
    description: "The aggregate flag provides an alternative way of representing an\
      \ aggregated (equivalent) element. It is applicable in cases when the dedicated\
      \ classes for equivalent equipment do not have all of the attributes necessary\
      \ to represent the required level of detail.  In case the flag is set to “true”\
      \ the single instance of equipment represents multiple pieces of equipment that\
      \ have been modelled together as an aggregate equivalent obtained by a network\
      \ reduction procedure. Examples would be power transformers or synchronous machines\
      \ operating in parallel modelled as a single aggregate power transformer or\
      \ aggregate synchronous machine.  \r\nThe attribute is not used for EquivalentBranch,\
      \ EquivalentShunt and EquivalentInjection."
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Equipment.aggregate
    multivalued: false
    alias: aggregate
    owner: EnergySource
    domain_of:
    - Equipment
    - ReadingType
    range: boolean
    required: false
  in_service:
    name: in_service
    description: Specifies the availability of the equipment. True means the equipment
      is available for topology processing, which determines if the equipment is energized
      or not. False means that the equipment is treated by network applications as
      if it is not in the model.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Equipment.inService
    multivalued: false
    alias: in_service
    owner: EnergySource
    domain_of:
    - Equipment
    - SvStatus
    - ProtectiveActionEquipment
    range: boolean
    required: false
  network_analysis_enabled:
    name: network_analysis_enabled
    description: The equipment is enabled to participate in network analysis.  If
      unspecified, the value is assumed to be true.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Equipment.networkAnalysisEnabled
    multivalued: false
    alias: network_analysis_enabled
    owner: EnergySource
    domain_of:
    - Equipment
    range: boolean
    required: false
  normally_in_service:
    name: normally_in_service
    description: Specifies the availability of the equipment under normal operating
      conditions. True means the equipment is available for topology processing, which
      determines if the equipment is energized or not. False means that the equipment
      is treated by network applications as if it is not in the model.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Equipment.normallyInService
    multivalued: false
    alias: normally_in_service
    owner: EnergySource
    domain_of:
    - Equipment
    range: boolean
    required: false
  weather_station:
    name: weather_station
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Equipment.WeatherStation
    multivalued: true
    alias: weather_station
    owner: EnergySource
    domain_of:
    - Equipment
    range: WeatherStation
    required: false
  operational_limit_set:
    name: operational_limit_set
    description: The operational limit sets associated with this equipment.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:Equipment.OperationalLimitSet
    multivalued: true
    alias: operational_limit_set
    owner: EnergySource
    domain_of:
    - ACDCTerminal
    - OperationalLimit
    - Equipment
    range: OperationalLimitSet
    required: false
  contingency_equipment:
    name: contingency_equipment
    description: The contingency equipments in which this equipment participates.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Equipment.ContingencyEquipment
    multivalued: true
    alias: contingency_equipment
    owner: EnergySource
    domain_of:
    - Equipment
    range: ContingencyEquipment
    required: false
  equipment_container:
    name: equipment_container
    description: Container of this equipment.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Equipment.EquipmentContainer
    multivalued: false
    alias: equipment_container
    owner: EnergySource
    domain_of:
    - Equipment
    range: EquipmentContainer
    required: false
  faults:
    name: faults
    description: All faults on this equipment.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Equipment.Faults
    multivalued: true
    alias: faults
    owner: EnergySource
    domain_of:
    - Equipment
    - Outage
    - FaultCauseType
    range: Fault
    required: false
  limit_dependency_model:
    name: limit_dependency_model
    description: Limit dependencymodels organized under this equipment as a means
      for organizing the model in a tree view.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    slot_uri: cim:Equipment.LimitDependencyModel
    multivalued: true
    alias: limit_dependency_model
    owner: EnergySource
    domain_of:
    - OperationalLimit
    - Equipment
    range: LimitDependency
    required: false
  eqiupment_limit_series_component:
    name: eqiupment_limit_series_component
    description: Equipment limit series calculation component to which this equipment
      contributes.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Equipment.EqiupmentLimitSeriesComponent
    multivalued: true
    alias: eqiupment_limit_series_component
    owner: EnergySource
    domain_of:
    - Equipment
    range: EquipmentLimitSeriesComponent
    required: false
  protective_action_equipment:
    name: protective_action_equipment
    description: Protective action is controlling equipment. This can be direct signals
      from the control center, or emulation of action done by protection equipment.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Equipment.ProtectiveActionEquipment
    multivalued: true
    alias: protective_action_equipment
    owner: EnergySource
    domain_of:
    - Equipment
    range: ProtectiveActionEquipment
    required: false
  pin_equipment:
    name: pin_equipment
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Equipment.PinEquipment
    multivalued: true
    alias: pin_equipment
    owner: EnergySource
    domain_of:
    - Equipment
    range: PinEquipment
    required: false
  equipment_unavailability_schedule:
    name: equipment_unavailability_schedule
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Equipment.EquipmentUnavailabilitySchedule
    multivalued: true
    alias: equipment_unavailability_schedule
    owner: EnergySource
    domain_of:
    - Equipment
    - UnavailabilitySwitchAction
    - UnavailablitySchedule
    range: EquipmentUnavailabilitySchedule
    required: false
  additional_equipment_container:
    name: additional_equipment_container
    description: Additional equipment container beyond the primary equipment container.  The
      equipment is contained in another equipment container, but also grouped with
      this equipment container.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Equipment.AdditionalEquipmentContainer
    multivalued: true
    alias: additional_equipment_container
    owner: EnergySource
    domain_of:
    - Equipment
    range: EquipmentContainer
    required: false
  usage_points:
    name: usage_points
    description: All usage points connected to the electrical grid through this equipment.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Equipment.UsagePoints
    multivalued: true
    alias: usage_points
    owner: EnergySource
    domain_of:
    - Equipment
    - CustomerAgreement
    - ServiceCategory
    - PricingStructure
    - EndDeviceControl
    - UsagePointGroup
    - ServiceLocation
    - MetrologyRequirement
    - ServiceSupplier
    - UsagePointLocation
    range: UsagePoint
    required: false
  outages:
    name: outages
    description: All outages in which this equipment is involved.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Equipment.Outages
    multivalued: true
    alias: outages
    owner: EnergySource
    domain_of:
    - Equipment
    range: Outage
    required: false
  operational_restrictions:
    name: operational_restrictions
    description: All operational restrictions for this equipment.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:Equipment.OperationalRestrictions
    multivalued: true
    alias: operational_restrictions
    owner: EnergySource
    domain_of:
    - Equipment
    - ProductAssetModel
    range: OperationalRestriction
    required: false
  controls:
    name: controls
    description: The controller outputs used to actually govern a regulating device,
      e.g. the magnetization of a synchronous machine or capacitor bank breaker actuator.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PowerSystemResource.Controls
    multivalued: true
    alias: controls
    owner: EnergySource
    domain_of:
    - PowerSystemResource
    - HostControlArea
    range: Control
    required: false
  measurements:
    name: measurements
    description: The measurements associated with this power system resource.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PowerSystemResource.Measurements
    multivalued: true
    alias: measurements
    owner: EnergySource
    domain_of:
    - PowerSystemResource
    - ACDCTerminal
    - Asset
    - Location
    - Procedure
    - AnalogLimitSet
    - AccumulatorLimitSet
    range: Measurement
    required: false
  psrtype:
    name: psrtype
    description: Custom classification for this power system resource.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PowerSystemResource.PSRType
    multivalued: false
    alias: psrtype
    owner: EnergySource
    domain_of:
    - PowerSystemResource
    range: PSRType
    required: false
  configuration_event:
    name: configuration_event
    description: All configuration events created for this Power System resource.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PowerSystemResource.ConfigurationEvent
    multivalued: true
    alias: configuration_event
    owner: EnergySource
    domain_of:
    - PowerSystemResource
    - FaultCauseType
    range: ConfigurationEvent
    required: false
  reporting_group:
    name: reporting_group
    description: Reporting groups to which this power system resource belongs.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PowerSystemResource.ReportingGroup
    multivalued: true
    alias: reporting_group
    owner: EnergySource
    domain_of:
    - PowerSystemResource
    - BusNameMarker
    - TopologicalNode
    - ReportingSuperGroup
    range: ReportingGroup
    required: false
  operating_share:
    name: operating_share
    description: The operating shares of this power system resource.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PowerSystemResource.OperatingShare
    multivalued: true
    alias: operating_share
    owner: EnergySource
    domain_of:
    - PowerSystemResource
    - OperatingParticipant
    range: OperatingShare
    required: false
  asset_datasheet:
    name: asset_datasheet
    description: Datasheet information for this power system resource.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PowerSystemResource.AssetDatasheet
    multivalued: false
    alias: asset_datasheet
    owner: EnergySource
    domain_of:
    - PowerSystemResource
    range: AssetInfo
    required: false
  verification_action:
    name: verification_action
    description: The verification action that is performed on the power system resource
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PowerSystemResource.VerificationAction
    multivalued: true
    alias: verification_action
    owner: EnergySource
    domain_of:
    - PowerSystemResource
    range: VerificationAction
    required: false
  clearances:
    name: clearances
    description: All clearances applicable to this power system resource.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PowerSystemResource.Clearances
    multivalued: true
    alias: clearances
    owner: EnergySource
    domain_of:
    - PowerSystemResource
    range: ClearanceDocument
    required: false
  generic_action:
    name: generic_action
    description: The generic action that is performed on the power system resource
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PowerSystemResource.GenericAction
    multivalued: true
    alias: generic_action
    owner: EnergySource
    domain_of:
    - PowerSystemResource
    range: GenericAction
    required: false
  psrevents:
    name: psrevents
    description: All events associated with this power system resource.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PowerSystemResource.PSREvents
    multivalued: true
    alias: psrevents
    owner: EnergySource
    domain_of:
    - PowerSystemResource
    range: PSREvent
    required: false
  assets:
    name: assets
    description: All assets represented by this power system resource. For example,
      multiple conductor assets are electrically modelled as a single AC line segment.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PowerSystemResource.Assets
    multivalued: true
    alias: assets
    owner: EnergySource
    domain_of:
    - PowerSystemResource
    - AssetInfo
    - Location
    - WorkTask
    - ErpRecDelvLineItem
    - AssetContainer
    - ActivityRecord
    - Procedure
    - ReliabilityInfo
    - AssetPropertyCurve
    - AssetOrganisationRole
    - ScheduledEvent
    range: Asset
    required: false
  location:
    name: location
    description: Location of this power system resource.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PowerSystemResource.Location
    multivalued: false
    alias: location
    owner: EnergySource
    domain_of:
    - PowerSystemResource
    - Asset
    - Incident
    - SwitchingOrder
    - TroubleOrder
    - Crew
    - Fault
    - PointOfSale
    - TroubleTicket
    - OutageOrder
    - EnvironmentalMonitoringStation
    - EnvironmentalLocationType
    - PositionPoint
    - FailureEvent
    range: Location
    required: false
  operational_tags:
    name: operational_tags
    description: All operational tags placed on this power system resource.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:PowerSystemResource.OperationalTags
    multivalued: true
    alias: operational_tags
    owner: EnergySource
    domain_of:
    - PowerSystemResource
    - Asset
    range: OperationalTag
    required: false
  alias_name:
    name: alias_name
    description: "The aliasName is free text human readable name of the object alternative\
      \ to IdentifiedObject.name. It may be non unique and may not correlate to a\
      \ naming hierarchy.\r\nThe attribute aliasName is retained because of backwards\
      \ compatibility between CIM relases. It is however recommended to replace aliasName\
      \ with the Name class as aliasName is planned for retirement at a future time.\r\
      \n\r\n"
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.aliasName
    multivalued: false
    alias: alias_name
    owner: EnergySource
    domain_of:
    - IdentifiedObject
    range: string
    required: false
  description:
    name: description
    description: The description is a free human readable text describing or naming
      the object. It may be non unique and may not correlate to a naming hierarchy.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.description
    multivalued: false
    alias: description
    owner: EnergySource
    domain_of:
    - IdentifiedObject
    - NameType
    - NameTypeAuthority
    - DataSet
    - SwitchingStepGroup
    - AreaReserveSpec
    range: string
    required: false
  m_rid:
    name: m_rid
    description: "Master resource identifier issued by a model authority. The mRID\
      \ is unique within an exchange context. Global uniqueness is easily achieved\
      \ by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is\
      \ strongly recommended.\r\nFor CIMXML data files in RDF syntax conforming to\
      \ IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify\
      \ CIM object elements."
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.mRID
    multivalued: false
    alias: m_rid
    owner: EnergySource
    domain_of:
    - IdentifiedObject
    - DataSet
    range: string
    required: false
  diagram_objects:
    name: diagram_objects
    description: The diagram objects that are associated with the domain object.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.DiagramObjects
    multivalued: true
    alias: diagram_objects
    owner: EnergySource
    domain_of:
    - IdentifiedObject
    range: DiagramObject
    required: false
  instance_set:
    name: instance_set
    description: Dataset containing the data objects.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.InstanceSet
    multivalued: false
    alias: instance_set
    owner: EnergySource
    domain_of:
    - IdentifiedObject
    range: InstanceSet
    required: true
  names:
    name: names
    description: All names of this identified object.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.Names
    multivalued: true
    alias: names
    owner: EnergySource
    domain_of:
    - IdentifiedObject
    - NameType
    range: Name
    required: false
  properties_cimdata_object:
    name: properties_cimdata_object
    description: The single CIM data object in the appropriate dataset context.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.PropertiesCIMDataObject
    multivalued: false
    alias: properties_cimdata_object
    owner: EnergySource
    domain_of:
    - IdentifiedObject
    range: ChangeSetMember
    required: false
  targeting_cimdata_object:
    name: targeting_cimdata_object
    description: Data objects registered.
    from_schema: https://cim.ucaiug.io/ns#TC57CIM
    rank: 1000
    slot_uri: cim:IdentifiedObject.TargetingCIMDataObject
    multivalued: true
    alias: targeting_cimdata_object
    owner: EnergySource
    domain_of:
    - IdentifiedObject
    range: ChangeSetMember
    required: false
class_uri: cim:EnergySource