Class: CurrentTransformer
Instrument transformer used to measure electrical qualities of the circuit that is being protected and/or monitored. Typically used as current transducer for the purpose of metering or protection. A typical secondary current rating would be 5A.
classDiagram
class CurrentTransformer
Sensor <|-- CurrentTransformer
CurrentTransformer : accuracy_class
CurrentTransformer : accuracy_limit
CurrentTransformer --> PerCent : accuracy_limit
CurrentTransformer : additional_equipment_container
CurrentTransformer --> EquipmentContainer : additional_equipment_container
CurrentTransformer : aggregate
CurrentTransformer : alias_name
CurrentTransformer : asset_datasheet
CurrentTransformer --> AssetInfo : asset_datasheet
CurrentTransformer : assets
CurrentTransformer --> Asset : assets
CurrentTransformer : clearances
CurrentTransformer --> ClearanceDocument : clearances
CurrentTransformer : configuration_event
CurrentTransformer --> ConfigurationEvent : configuration_event
CurrentTransformer : contingency_equipment
CurrentTransformer --> ContingencyEquipment : contingency_equipment
CurrentTransformer : controls
CurrentTransformer --> Control : controls
CurrentTransformer : core_burden
CurrentTransformer --> ActivePower : core_burden
CurrentTransformer : ct_class
CurrentTransformer : description
CurrentTransformer : diagram_objects
CurrentTransformer --> DiagramObject : diagram_objects
CurrentTransformer : eqiupment_limit_series_component
CurrentTransformer --> EquipmentLimitSeriesComponent : eqiupment_limit_series_component
CurrentTransformer : equipment_container
CurrentTransformer --> EquipmentContainer : equipment_container
CurrentTransformer : equipment_unavailability_schedule
CurrentTransformer --> EquipmentUnavailabilitySchedule : equipment_unavailability_schedule
CurrentTransformer : faults
CurrentTransformer --> Fault : faults
CurrentTransformer : generic_action
CurrentTransformer --> GenericAction : generic_action
CurrentTransformer : in_service
CurrentTransformer : instance_set
CurrentTransformer --> InstanceSet : instance_set
CurrentTransformer : limit_dependency_model
CurrentTransformer --> LimitDependency : limit_dependency_model
CurrentTransformer : location
CurrentTransformer --> Location : location
CurrentTransformer : m_rid
CurrentTransformer : measurements
CurrentTransformer --> Measurement : measurements
CurrentTransformer : names
CurrentTransformer --> Name : names
CurrentTransformer : network_analysis_enabled
CurrentTransformer : normally_in_service
CurrentTransformer : operating_share
CurrentTransformer --> OperatingShare : operating_share
CurrentTransformer : operational_limit_set
CurrentTransformer --> OperationalLimitSet : operational_limit_set
CurrentTransformer : operational_restrictions
CurrentTransformer --> OperationalRestriction : operational_restrictions
CurrentTransformer : operational_tags
CurrentTransformer --> OperationalTag : operational_tags
CurrentTransformer : outages
CurrentTransformer --> Outage : outages
CurrentTransformer : pin_equipment
CurrentTransformer --> PinEquipment : pin_equipment
CurrentTransformer : properties_cimdata_object
CurrentTransformer --> ChangeSetMember : properties_cimdata_object
CurrentTransformer : protective_action_equipment
CurrentTransformer --> ProtectiveActionEquipment : protective_action_equipment
CurrentTransformer : psrevents
CurrentTransformer --> PSREvent : psrevents
CurrentTransformer : psrtype
CurrentTransformer --> PSRType : psrtype
CurrentTransformer : reporting_group
CurrentTransformer --> ReportingGroup : reporting_group
CurrentTransformer : targeting_cimdata_object
CurrentTransformer --> ChangeSetMember : targeting_cimdata_object
CurrentTransformer : terminal
CurrentTransformer --> Terminal : terminal
CurrentTransformer : usage
CurrentTransformer : usage_points
CurrentTransformer --> UsagePoint : usage_points
CurrentTransformer : verification_action
CurrentTransformer --> VerificationAction : verification_action
CurrentTransformer : weather_station
CurrentTransformer --> WeatherStation : weather_station
Inheritance
- IdentifiedObject
- PowerSystemResource
- Equipment
- AuxiliaryEquipment
- Sensor
- CurrentTransformer
- Sensor
- AuxiliaryEquipment
- Equipment
- PowerSystemResource
Slots
| Name | Cardinality and Range | Description | Inheritance |
|---|---|---|---|
| accuracy_class | 0..1 String |
CT accuracy classification | direct |
| accuracy_limit | 0..1 PerCent |
Percent of rated current for which the CT remains accurate within specified l... | direct |
| core_burden | 0..1 ActivePower |
Power burden of the CT core | direct |
| ct_class | 0..1 String |
CT classification; i | direct |
| usage | 0..1 String |
Intended usage of the CT; i | direct |
| terminal | 1..1 Terminal |
The Terminal at the equipment where the AuxiliaryEquipment is attached | AuxiliaryEquipment |
| aggregate | 0..1 Boolean |
The aggregate flag provides an alternative way of representing an aggregated ... | Equipment |
| in_service | 0..1 Boolean |
Specifies the availability of the equipment | Equipment |
| network_analysis_enabled | 0..1 Boolean |
The equipment is enabled to participate in network analysis | Equipment |
| normally_in_service | 0..1 Boolean |
Specifies the availability of the equipment under normal operating conditions | Equipment |
| weather_station | 0..* WeatherStation |
Equipment | |
| operational_limit_set | 0..* OperationalLimitSet |
The operational limit sets associated with this equipment | Equipment |
| contingency_equipment | 0..* ContingencyEquipment |
The contingency equipments in which this equipment participates | Equipment |
| equipment_container | 0..1 EquipmentContainer |
Container of this equipment | Equipment |
| faults | 0..* Fault |
All faults on this equipment | Equipment |
| limit_dependency_model | 0..* LimitDependency |
Limit dependencymodels organized under this equipment as a means for organizi... | Equipment |
| eqiupment_limit_series_component | 0..* EquipmentLimitSeriesComponent |
Equipment limit series calculation component to which this equipment contribu... | Equipment |
| protective_action_equipment | 0..* ProtectiveActionEquipment |
Protective action is controlling equipment | Equipment |
| pin_equipment | 0..* PinEquipment |
Equipment | |
| equipment_unavailability_schedule | 0..* EquipmentUnavailabilitySchedule |
Equipment | |
| additional_equipment_container | 0..* EquipmentContainer |
Additional equipment container beyond the primary equipment container | Equipment |
| usage_points | 0..* UsagePoint |
All usage points connected to the electrical grid through this equipment | Equipment |
| outages | 0..* Outage |
All outages in which this equipment is involved | Equipment |
| operational_restrictions | 0..* OperationalRestriction |
All operational restrictions for this equipment | Equipment |
| controls | 0..* Control |
The controller outputs used to actually govern a regulating device, e | PowerSystemResource |
| measurements | 0..* Measurement |
The measurements associated with this power system resource | PowerSystemResource |
| psrtype | 0..1 PSRType |
Custom classification for this power system resource | PowerSystemResource |
| configuration_event | 0..* ConfigurationEvent |
All configuration events created for this Power System resource | PowerSystemResource |
| reporting_group | 0..* ReportingGroup |
Reporting groups to which this power system resource belongs | PowerSystemResource |
| operating_share | 0..* OperatingShare |
The operating shares of this power system resource | PowerSystemResource |
| asset_datasheet | 0..1 AssetInfo |
Datasheet information for this power system resource | PowerSystemResource |
| verification_action | 0..* VerificationAction |
The verification action that is performed on the power system resource | PowerSystemResource |
| clearances | 0..* ClearanceDocument |
All clearances applicable to this power system resource | PowerSystemResource |
| generic_action | 0..* GenericAction |
The generic action that is performed on the power system resource | PowerSystemResource |
| psrevents | 0..* PSREvent |
All events associated with this power system resource | PowerSystemResource |
| assets | 0..* Asset |
All assets represented by this power system resource | PowerSystemResource |
| location | 0..1 Location |
Location of this power system resource | PowerSystemResource |
| operational_tags | 0..* OperationalTag |
All operational tags placed on this power system resource | PowerSystemResource |
| alias_name | 0..1 String |
The aliasName is free text human readable name of the object alternative to I... | IdentifiedObject |
| description | 0..1 String |
The description is a free human readable text describing or naming the object | IdentifiedObject |
| m_rid | 0..1 String |
Master resource identifier issued by a model authority | IdentifiedObject |
| diagram_objects | 0..* DiagramObject |
The diagram objects that are associated with the domain object | IdentifiedObject |
| instance_set | 1..1 InstanceSet |
Dataset containing the data objects | IdentifiedObject |
| names | 0..* Name |
All names of this identified object | IdentifiedObject |
| properties_cimdata_object | 0..1 ChangeSetMember |
The single CIM data object in the appropriate dataset context | IdentifiedObject |
| targeting_cimdata_object | 0..* ChangeSetMember |
Data objects registered | IdentifiedObject |
Identifier and Mapping Information
Schema Source
- from schema: https://cim.ucaiug.io/ns#TC57CIM
Mappings
| Mapping Type | Mapped Value |
|---|---|
| self | cim:CurrentTransformer |
| native | cim:CurrentTransformer |
LinkML Source
Direct
name: CurrentTransformer
description: Instrument transformer used to measure electrical qualities of the circuit
that is being protected and/or monitored. Typically used as current transducer for
the purpose of metering or protection. A typical secondary current rating would
be 5A.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
is_a: Sensor
attributes:
accuracy_class:
name: accuracy_class
description: CT accuracy classification.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:CurrentTransformer.accuracyClass
multivalued: false
domain_of:
- CurrentTransformer
- PotentialTransformer
- CurrentTransformerInfo
- PotentialTransformerInfo
range: string
required: false
accuracy_limit:
name: accuracy_limit
description: "Percent of rated current for which the CT remains accurate within\
\ specified limits.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:CurrentTransformer.accuracyLimit
multivalued: false
domain_of:
- CurrentTransformer
- CurrentTransformerInfo
range: PerCent
required: false
core_burden:
name: core_burden
description: "Power burden of the CT core.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:CurrentTransformer.coreBurden
multivalued: false
domain_of:
- CurrentTransformer
range: ActivePower
required: false
ct_class:
name: ct_class
description: CT classification; i.e. class 10P.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:CurrentTransformer.ctClass
multivalued: false
domain_of:
- CurrentTransformer
- CurrentTransformerInfo
range: string
required: false
usage:
name: usage
description: Intended usage of the CT; i.e. metering, protection.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:CurrentTransformer.usage
multivalued: false
domain_of:
- WireSpacingInfo
- CurrentTransformer
- CurrentTransformerInfo
range: string
required: false
class_uri: cim:CurrentTransformer
Induced
name: CurrentTransformer
description: Instrument transformer used to measure electrical qualities of the circuit
that is being protected and/or monitored. Typically used as current transducer for
the purpose of metering or protection. A typical secondary current rating would
be 5A.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
is_a: Sensor
attributes:
accuracy_class:
name: accuracy_class
description: CT accuracy classification.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:CurrentTransformer.accuracyClass
multivalued: false
alias: accuracy_class
owner: CurrentTransformer
domain_of:
- CurrentTransformer
- PotentialTransformer
- CurrentTransformerInfo
- PotentialTransformerInfo
range: string
required: false
accuracy_limit:
name: accuracy_limit
description: "Percent of rated current for which the CT remains accurate within\
\ specified limits.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:CurrentTransformer.accuracyLimit
multivalued: false
alias: accuracy_limit
owner: CurrentTransformer
domain_of:
- CurrentTransformer
- CurrentTransformerInfo
range: PerCent
required: false
core_burden:
name: core_burden
description: "Power burden of the CT core.\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:CurrentTransformer.coreBurden
multivalued: false
alias: core_burden
owner: CurrentTransformer
domain_of:
- CurrentTransformer
range: ActivePower
required: false
ct_class:
name: ct_class
description: CT classification; i.e. class 10P.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:CurrentTransformer.ctClass
multivalued: false
alias: ct_class
owner: CurrentTransformer
domain_of:
- CurrentTransformer
- CurrentTransformerInfo
range: string
required: false
usage:
name: usage
description: Intended usage of the CT; i.e. metering, protection.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:CurrentTransformer.usage
multivalued: false
alias: usage
owner: CurrentTransformer
domain_of:
- WireSpacingInfo
- CurrentTransformer
- CurrentTransformerInfo
range: string
required: false
terminal:
name: terminal
description: The Terminal at the equipment where the AuxiliaryEquipment is attached.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:AuxiliaryEquipment.Terminal
multivalued: false
alias: terminal
owner: CurrentTransformer
domain_of:
- BusNameMarker
- OperationalLimitSet
- TopologicalNode
- TransformerEnd
- Measurement
- Bushing
- TieFlow
- SvPowerFlow
- RegulatingControl
- RemoteInputSignal
- BranchGroupTerminal
- AuxiliaryEquipment
- EquipmentFault
- PinTerminal
range: Terminal
required: true
aggregate:
name: aggregate
description: "The aggregate flag provides an alternative way of representing an\
\ aggregated (equivalent) element. It is applicable in cases when the dedicated\
\ classes for equivalent equipment do not have all of the attributes necessary\
\ to represent the required level of detail. In case the flag is set to “true”\
\ the single instance of equipment represents multiple pieces of equipment that\
\ have been modelled together as an aggregate equivalent obtained by a network\
\ reduction procedure. Examples would be power transformers or synchronous machines\
\ operating in parallel modelled as a single aggregate power transformer or\
\ aggregate synchronous machine. \r\nThe attribute is not used for EquivalentBranch,\
\ EquivalentShunt and EquivalentInjection."
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.aggregate
multivalued: false
alias: aggregate
owner: CurrentTransformer
domain_of:
- Equipment
- ReadingType
range: boolean
required: false
in_service:
name: in_service
description: Specifies the availability of the equipment. True means the equipment
is available for topology processing, which determines if the equipment is energized
or not. False means that the equipment is treated by network applications as
if it is not in the model.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.inService
multivalued: false
alias: in_service
owner: CurrentTransformer
domain_of:
- Equipment
- SvStatus
- ProtectiveActionEquipment
range: boolean
required: false
network_analysis_enabled:
name: network_analysis_enabled
description: The equipment is enabled to participate in network analysis. If
unspecified, the value is assumed to be true.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.networkAnalysisEnabled
multivalued: false
alias: network_analysis_enabled
owner: CurrentTransformer
domain_of:
- Equipment
range: boolean
required: false
normally_in_service:
name: normally_in_service
description: Specifies the availability of the equipment under normal operating
conditions. True means the equipment is available for topology processing, which
determines if the equipment is energized or not. False means that the equipment
is treated by network applications as if it is not in the model.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.normallyInService
multivalued: false
alias: normally_in_service
owner: CurrentTransformer
domain_of:
- Equipment
range: boolean
required: false
weather_station:
name: weather_station
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.WeatherStation
multivalued: true
alias: weather_station
owner: CurrentTransformer
domain_of:
- Equipment
range: WeatherStation
required: false
operational_limit_set:
name: operational_limit_set
description: The operational limit sets associated with this equipment.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:Equipment.OperationalLimitSet
multivalued: true
alias: operational_limit_set
owner: CurrentTransformer
domain_of:
- ACDCTerminal
- OperationalLimit
- Equipment
range: OperationalLimitSet
required: false
contingency_equipment:
name: contingency_equipment
description: The contingency equipments in which this equipment participates.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.ContingencyEquipment
multivalued: true
alias: contingency_equipment
owner: CurrentTransformer
domain_of:
- Equipment
range: ContingencyEquipment
required: false
equipment_container:
name: equipment_container
description: Container of this equipment.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.EquipmentContainer
multivalued: false
alias: equipment_container
owner: CurrentTransformer
domain_of:
- Equipment
range: EquipmentContainer
required: false
faults:
name: faults
description: All faults on this equipment.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.Faults
multivalued: true
alias: faults
owner: CurrentTransformer
domain_of:
- Equipment
- Outage
- FaultCauseType
range: Fault
required: false
limit_dependency_model:
name: limit_dependency_model
description: Limit dependencymodels organized under this equipment as a means
for organizing the model in a tree view.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:Equipment.LimitDependencyModel
multivalued: true
alias: limit_dependency_model
owner: CurrentTransformer
domain_of:
- OperationalLimit
- Equipment
range: LimitDependency
required: false
eqiupment_limit_series_component:
name: eqiupment_limit_series_component
description: Equipment limit series calculation component to which this equipment
contributes.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.EqiupmentLimitSeriesComponent
multivalued: true
alias: eqiupment_limit_series_component
owner: CurrentTransformer
domain_of:
- Equipment
range: EquipmentLimitSeriesComponent
required: false
protective_action_equipment:
name: protective_action_equipment
description: Protective action is controlling equipment. This can be direct signals
from the control center, or emulation of action done by protection equipment.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.ProtectiveActionEquipment
multivalued: true
alias: protective_action_equipment
owner: CurrentTransformer
domain_of:
- Equipment
range: ProtectiveActionEquipment
required: false
pin_equipment:
name: pin_equipment
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.PinEquipment
multivalued: true
alias: pin_equipment
owner: CurrentTransformer
domain_of:
- Equipment
range: PinEquipment
required: false
equipment_unavailability_schedule:
name: equipment_unavailability_schedule
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.EquipmentUnavailabilitySchedule
multivalued: true
alias: equipment_unavailability_schedule
owner: CurrentTransformer
domain_of:
- Equipment
- UnavailabilitySwitchAction
- UnavailablitySchedule
range: EquipmentUnavailabilitySchedule
required: false
additional_equipment_container:
name: additional_equipment_container
description: Additional equipment container beyond the primary equipment container. The
equipment is contained in another equipment container, but also grouped with
this equipment container.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.AdditionalEquipmentContainer
multivalued: true
alias: additional_equipment_container
owner: CurrentTransformer
domain_of:
- Equipment
range: EquipmentContainer
required: false
usage_points:
name: usage_points
description: All usage points connected to the electrical grid through this equipment.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.UsagePoints
multivalued: true
alias: usage_points
owner: CurrentTransformer
domain_of:
- Equipment
- CustomerAgreement
- ServiceCategory
- PricingStructure
- EndDeviceControl
- UsagePointGroup
- ServiceLocation
- MetrologyRequirement
- ServiceSupplier
- UsagePointLocation
range: UsagePoint
required: false
outages:
name: outages
description: All outages in which this equipment is involved.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.Outages
multivalued: true
alias: outages
owner: CurrentTransformer
domain_of:
- Equipment
range: Outage
required: false
operational_restrictions:
name: operational_restrictions
description: All operational restrictions for this equipment.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.OperationalRestrictions
multivalued: true
alias: operational_restrictions
owner: CurrentTransformer
domain_of:
- Equipment
- ProductAssetModel
range: OperationalRestriction
required: false
controls:
name: controls
description: The controller outputs used to actually govern a regulating device,
e.g. the magnetization of a synchronous machine or capacitor bank breaker actuator.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.Controls
multivalued: true
alias: controls
owner: CurrentTransformer
domain_of:
- PowerSystemResource
- HostControlArea
range: Control
required: false
measurements:
name: measurements
description: The measurements associated with this power system resource.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.Measurements
multivalued: true
alias: measurements
owner: CurrentTransformer
domain_of:
- PowerSystemResource
- ACDCTerminal
- Asset
- Location
- Procedure
- AnalogLimitSet
- AccumulatorLimitSet
range: Measurement
required: false
psrtype:
name: psrtype
description: Custom classification for this power system resource.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.PSRType
multivalued: false
alias: psrtype
owner: CurrentTransformer
domain_of:
- PowerSystemResource
range: PSRType
required: false
configuration_event:
name: configuration_event
description: All configuration events created for this Power System resource.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.ConfigurationEvent
multivalued: true
alias: configuration_event
owner: CurrentTransformer
domain_of:
- PowerSystemResource
- FaultCauseType
range: ConfigurationEvent
required: false
reporting_group:
name: reporting_group
description: Reporting groups to which this power system resource belongs.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.ReportingGroup
multivalued: true
alias: reporting_group
owner: CurrentTransformer
domain_of:
- PowerSystemResource
- BusNameMarker
- TopologicalNode
- ReportingSuperGroup
range: ReportingGroup
required: false
operating_share:
name: operating_share
description: The operating shares of this power system resource.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.OperatingShare
multivalued: true
alias: operating_share
owner: CurrentTransformer
domain_of:
- PowerSystemResource
- OperatingParticipant
range: OperatingShare
required: false
asset_datasheet:
name: asset_datasheet
description: Datasheet information for this power system resource.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.AssetDatasheet
multivalued: false
alias: asset_datasheet
owner: CurrentTransformer
domain_of:
- PowerSystemResource
range: AssetInfo
required: false
verification_action:
name: verification_action
description: The verification action that is performed on the power system resource
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.VerificationAction
multivalued: true
alias: verification_action
owner: CurrentTransformer
domain_of:
- PowerSystemResource
range: VerificationAction
required: false
clearances:
name: clearances
description: All clearances applicable to this power system resource.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.Clearances
multivalued: true
alias: clearances
owner: CurrentTransformer
domain_of:
- PowerSystemResource
range: ClearanceDocument
required: false
generic_action:
name: generic_action
description: The generic action that is performed on the power system resource
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.GenericAction
multivalued: true
alias: generic_action
owner: CurrentTransformer
domain_of:
- PowerSystemResource
range: GenericAction
required: false
psrevents:
name: psrevents
description: All events associated with this power system resource.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.PSREvents
multivalued: true
alias: psrevents
owner: CurrentTransformer
domain_of:
- PowerSystemResource
range: PSREvent
required: false
assets:
name: assets
description: All assets represented by this power system resource. For example,
multiple conductor assets are electrically modelled as a single AC line segment.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.Assets
multivalued: true
alias: assets
owner: CurrentTransformer
domain_of:
- PowerSystemResource
- AssetInfo
- Location
- WorkTask
- ErpRecDelvLineItem
- AssetContainer
- ActivityRecord
- Procedure
- ReliabilityInfo
- AssetPropertyCurve
- AssetOrganisationRole
- ScheduledEvent
range: Asset
required: false
location:
name: location
description: Location of this power system resource.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.Location
multivalued: false
alias: location
owner: CurrentTransformer
domain_of:
- PowerSystemResource
- Asset
- Incident
- SwitchingOrder
- TroubleOrder
- Crew
- Fault
- PointOfSale
- TroubleTicket
- OutageOrder
- EnvironmentalMonitoringStation
- EnvironmentalLocationType
- PositionPoint
- FailureEvent
range: Location
required: false
operational_tags:
name: operational_tags
description: All operational tags placed on this power system resource.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.OperationalTags
multivalued: true
alias: operational_tags
owner: CurrentTransformer
domain_of:
- PowerSystemResource
- Asset
range: OperationalTag
required: false
alias_name:
name: alias_name
description: "The aliasName is free text human readable name of the object alternative\
\ to IdentifiedObject.name. It may be non unique and may not correlate to a\
\ naming hierarchy.\r\nThe attribute aliasName is retained because of backwards\
\ compatibility between CIM relases. It is however recommended to replace aliasName\
\ with the Name class as aliasName is planned for retirement at a future time.\r\
\n\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.aliasName
multivalued: false
alias: alias_name
owner: CurrentTransformer
domain_of:
- IdentifiedObject
range: string
required: false
description:
name: description
description: The description is a free human readable text describing or naming
the object. It may be non unique and may not correlate to a naming hierarchy.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.description
multivalued: false
alias: description
owner: CurrentTransformer
domain_of:
- IdentifiedObject
- NameType
- NameTypeAuthority
- DataSet
- SwitchingStepGroup
- AreaReserveSpec
range: string
required: false
m_rid:
name: m_rid
description: "Master resource identifier issued by a model authority. The mRID\
\ is unique within an exchange context. Global uniqueness is easily achieved\
\ by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is\
\ strongly recommended.\r\nFor CIMXML data files in RDF syntax conforming to\
\ IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify\
\ CIM object elements."
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.mRID
multivalued: false
alias: m_rid
owner: CurrentTransformer
domain_of:
- IdentifiedObject
- DataSet
range: string
required: false
diagram_objects:
name: diagram_objects
description: The diagram objects that are associated with the domain object.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.DiagramObjects
multivalued: true
alias: diagram_objects
owner: CurrentTransformer
domain_of:
- IdentifiedObject
range: DiagramObject
required: false
instance_set:
name: instance_set
description: Dataset containing the data objects.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.InstanceSet
multivalued: false
alias: instance_set
owner: CurrentTransformer
domain_of:
- IdentifiedObject
range: InstanceSet
required: true
names:
name: names
description: All names of this identified object.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.Names
multivalued: true
alias: names
owner: CurrentTransformer
domain_of:
- IdentifiedObject
- NameType
range: Name
required: false
properties_cimdata_object:
name: properties_cimdata_object
description: The single CIM data object in the appropriate dataset context.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.PropertiesCIMDataObject
multivalued: false
alias: properties_cimdata_object
owner: CurrentTransformer
domain_of:
- IdentifiedObject
range: ChangeSetMember
required: false
targeting_cimdata_object:
name: targeting_cimdata_object
description: Data objects registered.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.TargetingCIMDataObject
multivalued: true
alias: targeting_cimdata_object
owner: CurrentTransformer
domain_of:
- IdentifiedObject
range: ChangeSetMember
required: false
class_uri: cim:CurrentTransformer