Class: ACDCConverter
A unit with valves for three phases, together with unit control equipment, essential protective and switching devices, DC storage capacitors, phase reactors and auxiliaries, if any, used for conversion.
URI: cim:ACDCConverter
classDiagram
class ACDCConverter
ConductingEquipment <|-- ACDCConverter
ACDCConverter <|-- VsConverter
ACDCConverter <|-- CsConverter
ACDCConverter : additional_equipment_container
ACDCConverter --> EquipmentContainer : additional_equipment_container
ACDCConverter : aggregate
ACDCConverter : alias_name
ACDCConverter : asset_datasheet
ACDCConverter --> AssetInfo : asset_datasheet
ACDCConverter : assets
ACDCConverter --> Asset : assets
ACDCConverter : base_s
ACDCConverter --> ApparentPower : base_s
ACDCConverter : base_voltage
ACDCConverter --> BaseVoltage : base_voltage
ACDCConverter : clearances
ACDCConverter --> ClearanceDocument : clearances
ACDCConverter : configuration_event
ACDCConverter --> ConfigurationEvent : configuration_event
ACDCConverter : contingency_equipment
ACDCConverter --> ContingencyEquipment : contingency_equipment
ACDCConverter : controls
ACDCConverter --> Control : controls
ACDCConverter : dcterminals
ACDCConverter --> ACDCConverterDCTerminal : dcterminals
ACDCConverter : description
ACDCConverter : diagram_objects
ACDCConverter --> DiagramObject : diagram_objects
ACDCConverter : eqiupment_limit_series_component
ACDCConverter --> EquipmentLimitSeriesComponent : eqiupment_limit_series_component
ACDCConverter : equipment_container
ACDCConverter --> EquipmentContainer : equipment_container
ACDCConverter : equipment_unavailability_schedule
ACDCConverter --> EquipmentUnavailabilitySchedule : equipment_unavailability_schedule
ACDCConverter : faults
ACDCConverter --> Fault : faults
ACDCConverter : generic_action
ACDCConverter --> GenericAction : generic_action
ACDCConverter : grounding_action
ACDCConverter --> GroundAction : grounding_action
ACDCConverter : idc
ACDCConverter --> CurrentFlow : idc
ACDCConverter : idle_loss
ACDCConverter --> ActivePower : idle_loss
ACDCConverter : in_service
ACDCConverter : instance_set
ACDCConverter --> InstanceSet : instance_set
ACDCConverter : jumping_action
ACDCConverter --> JumperAction : jumping_action
ACDCConverter : limit_dependency_model
ACDCConverter --> LimitDependency : limit_dependency_model
ACDCConverter : location
ACDCConverter --> Location : location
ACDCConverter : m_rid
ACDCConverter : max_p
ACDCConverter --> ActivePower : max_p
ACDCConverter : max_udc
ACDCConverter --> Voltage : max_udc
ACDCConverter : measurements
ACDCConverter --> Measurement : measurements
ACDCConverter : min_p
ACDCConverter --> ActivePower : min_p
ACDCConverter : min_udc
ACDCConverter --> Voltage : min_udc
ACDCConverter : names
ACDCConverter --> Name : names
ACDCConverter : network_analysis_enabled
ACDCConverter : normally_in_service
ACDCConverter : number_of_valves
ACDCConverter : operating_share
ACDCConverter --> OperatingShare : operating_share
ACDCConverter : operational_limit_set
ACDCConverter --> OperationalLimitSet : operational_limit_set
ACDCConverter : operational_restrictions
ACDCConverter --> OperationalRestriction : operational_restrictions
ACDCConverter : operational_tags
ACDCConverter --> OperationalTag : operational_tags
ACDCConverter : outage
ACDCConverter --> Outage : outage
ACDCConverter : outages
ACDCConverter --> Outage : outages
ACDCConverter : p
ACDCConverter --> ActivePower : p
ACDCConverter : pcc_terminal
ACDCConverter --> Terminal : pcc_terminal
ACDCConverter : pin_equipment
ACDCConverter --> PinEquipment : pin_equipment
ACDCConverter : pole_loss_p
ACDCConverter --> ActivePower : pole_loss_p
ACDCConverter : properties_cimdata_object
ACDCConverter --> ChangeSetMember : properties_cimdata_object
ACDCConverter : protection_equipments
ACDCConverter --> ProtectionEquipment : protection_equipments
ACDCConverter : protective_action_adjustment
ACDCConverter --> ProtectiveActionAdjustment : protective_action_adjustment
ACDCConverter : protective_action_equipment
ACDCConverter --> ProtectiveActionEquipment : protective_action_equipment
ACDCConverter : psrevents
ACDCConverter --> PSREvent : psrevents
ACDCConverter : psrtype
ACDCConverter --> PSRType : psrtype
ACDCConverter : q
ACDCConverter --> ReactivePower : q
ACDCConverter : rated_udc
ACDCConverter --> Voltage : rated_udc
ACDCConverter : reporting_group
ACDCConverter --> ReportingGroup : reporting_group
ACDCConverter : resistive_loss
ACDCConverter --> Resistance : resistive_loss
ACDCConverter : sv_status
ACDCConverter --> SvStatus : sv_status
ACDCConverter : switching_loss
ACDCConverter --> ActivePowerPerCurrentFlow : switching_loss
ACDCConverter : target_ppcc
ACDCConverter --> ActivePower : target_ppcc
ACDCConverter : target_udc
ACDCConverter --> Voltage : target_udc
ACDCConverter : targeting_cimdata_object
ACDCConverter --> ChangeSetMember : targeting_cimdata_object
ACDCConverter : terminals
ACDCConverter --> Terminal : terminals
ACDCConverter : uc
ACDCConverter --> Voltage : uc
ACDCConverter : udc
ACDCConverter --> Voltage : udc
ACDCConverter : usage_points
ACDCConverter --> UsagePoint : usage_points
ACDCConverter : valve_u
ACDCConverter --> Voltage : valve_u
ACDCConverter : verification_action
ACDCConverter --> VerificationAction : verification_action
ACDCConverter : weather_station
ACDCConverter --> WeatherStation : weather_station
Inheritance
- IdentifiedObject
- PowerSystemResource
- Equipment
- ConductingEquipment
- ACDCConverter
- ConductingEquipment
- Equipment
- PowerSystemResource
Slots
| Name | Cardinality and Range | Description | Inheritance |
|---|---|---|---|
| base_s | 0..1 ApparentPower |
Base apparent power of the converter pole | direct |
| idc | 0..1 CurrentFlow |
Converter DC current, also called Id | direct |
| idle_loss | 0..1 ActivePower |
Active power loss in pole at no power transfer | direct |
| max_p | 0..1 ActivePower |
Maximum active power limit | direct |
| max_udc | 0..1 Voltage |
The maximum voltage on the DC side at which the converter should operate | direct |
| min_p | 0..1 ActivePower |
Minimum active power limit | direct |
| min_udc | 0..1 Voltage |
The minimum voltage on the DC side at which the converter should operate | direct |
| number_of_valves | 0..1 Integer |
Number of valves in the converter | direct |
| p | 0..1 ActivePower |
Active power at the point of common coupling | direct |
| pole_loss_p | 0..1 ActivePower |
The active power loss at a DC Pole | |
| direct | |||
| q | 0..1 ReactivePower |
Reactive power at the point of common coupling | direct |
| rated_udc | 0..1 Voltage |
Rated converter DC voltage, also called UdN | direct |
| resistive_loss | 0..1 Resistance |
It is converter’s configuration data used in power flow | direct |
| switching_loss | 0..1 ActivePowerPerCurrentFlow |
Switching losses, relative to the base apparent power 'baseS' | direct |
| target_ppcc | 0..1 ActivePower |
Real power injection target in AC grid, at point of common coupling | direct |
| target_udc | 0..1 Voltage |
Target value for DC voltage magnitude | direct |
| uc | 0..1 Voltage |
Line-to-line converter voltage, the voltage at the AC side of the valve | direct |
| udc | 0..1 Voltage |
Converter voltage at the DC side, also called Ud | direct |
| valve_u | 0..1 Voltage |
Valve threshold voltage, also called Uvalve | direct |
| pcc_terminal | 0..1 Terminal |
Point of common coupling terminal for this converter DC side | direct |
| dcterminals | 0..* ACDCConverterDCTerminal |
A DC converter have DC converter terminals | direct |
| protective_action_adjustment | 0..* ProtectiveActionAdjustment |
The operating condition to the Conducting Equipment is changed when protectiv... | ConductingEquipment |
| sv_status | 0..* SvStatus |
The status state variable associated with this conducting equipment | ConductingEquipment |
| protection_equipments | 0..* ProtectionEquipment |
Protection equipment used to protect specific conducting equipment | ConductingEquipment |
| base_voltage | 0..1 BaseVoltage |
Base voltage of this conducting equipment | ConductingEquipment |
| terminals | 0..* Terminal |
Conducting equipment have terminals that may be connected to other conducting... | ConductingEquipment |
| jumping_action | 0..1 JumperAction |
Jumper action involving jumping operation on this conducting equipment | ConductingEquipment |
| grounding_action | 0..1 GroundAction |
Action involving grounding operation on this conducting equipment | ConductingEquipment |
| outage | 0..1 Outage |
The outage that is isolated by the outage isolation equipment | ConductingEquipment |
| aggregate | 0..1 Boolean |
The aggregate flag provides an alternative way of representing an aggregated ... | Equipment |
| in_service | 0..1 Boolean |
Specifies the availability of the equipment | Equipment |
| network_analysis_enabled | 0..1 Boolean |
The equipment is enabled to participate in network analysis | Equipment |
| normally_in_service | 0..1 Boolean |
Specifies the availability of the equipment under normal operating conditions | Equipment |
| weather_station | 0..* WeatherStation |
Equipment | |
| operational_limit_set | 0..* OperationalLimitSet |
The operational limit sets associated with this equipment | Equipment |
| contingency_equipment | 0..* ContingencyEquipment |
The contingency equipments in which this equipment participates | Equipment |
| equipment_container | 0..1 EquipmentContainer |
Container of this equipment | Equipment |
| faults | 0..* Fault |
All faults on this equipment | Equipment |
| limit_dependency_model | 0..* LimitDependency |
Limit dependencymodels organized under this equipment as a means for organizi... | Equipment |
| eqiupment_limit_series_component | 0..* EquipmentLimitSeriesComponent |
Equipment limit series calculation component to which this equipment contribu... | Equipment |
| protective_action_equipment | 0..* ProtectiveActionEquipment |
Protective action is controlling equipment | Equipment |
| pin_equipment | 0..* PinEquipment |
Equipment | |
| equipment_unavailability_schedule | 0..* EquipmentUnavailabilitySchedule |
Equipment | |
| additional_equipment_container | 0..* EquipmentContainer |
Additional equipment container beyond the primary equipment container | Equipment |
| usage_points | 0..* UsagePoint |
All usage points connected to the electrical grid through this equipment | Equipment |
| outages | 0..* Outage |
All outages in which this equipment is involved | Equipment |
| operational_restrictions | 0..* OperationalRestriction |
All operational restrictions for this equipment | Equipment |
| controls | 0..* Control |
The controller outputs used to actually govern a regulating device, e | PowerSystemResource |
| measurements | 0..* Measurement |
The measurements associated with this power system resource | PowerSystemResource |
| psrtype | 0..1 PSRType |
Custom classification for this power system resource | PowerSystemResource |
| configuration_event | 0..* ConfigurationEvent |
All configuration events created for this Power System resource | PowerSystemResource |
| reporting_group | 0..* ReportingGroup |
Reporting groups to which this power system resource belongs | PowerSystemResource |
| operating_share | 0..* OperatingShare |
The operating shares of this power system resource | PowerSystemResource |
| asset_datasheet | 0..1 AssetInfo |
Datasheet information for this power system resource | PowerSystemResource |
| verification_action | 0..* VerificationAction |
The verification action that is performed on the power system resource | PowerSystemResource |
| clearances | 0..* ClearanceDocument |
All clearances applicable to this power system resource | PowerSystemResource |
| generic_action | 0..* GenericAction |
The generic action that is performed on the power system resource | PowerSystemResource |
| psrevents | 0..* PSREvent |
All events associated with this power system resource | PowerSystemResource |
| assets | 0..* Asset |
All assets represented by this power system resource | PowerSystemResource |
| location | 0..1 Location |
Location of this power system resource | PowerSystemResource |
| operational_tags | 0..* OperationalTag |
All operational tags placed on this power system resource | PowerSystemResource |
| alias_name | 0..1 String |
The aliasName is free text human readable name of the object alternative to I... | IdentifiedObject |
| description | 0..1 String |
The description is a free human readable text describing or naming the object | IdentifiedObject |
| m_rid | 0..1 String |
Master resource identifier issued by a model authority | IdentifiedObject |
| diagram_objects | 0..* DiagramObject |
The diagram objects that are associated with the domain object | IdentifiedObject |
| instance_set | 1..1 InstanceSet |
Dataset containing the data objects | IdentifiedObject |
| names | 0..* Name |
All names of this identified object | IdentifiedObject |
| properties_cimdata_object | 0..1 ChangeSetMember |
The single CIM data object in the appropriate dataset context | IdentifiedObject |
| targeting_cimdata_object | 0..* ChangeSetMember |
Data objects registered | IdentifiedObject |
Usages
| used by | used in | type | used |
|---|---|---|---|
| Terminal | converter_dcsides | range | ACDCConverter |
| MktTerminal | converter_dcsides | range | ACDCConverter |
| ACDCConverterDCTerminal | dcconducting_equipment | range | ACDCConverter |
Identifier and Mapping Information
Schema Source
- from schema: https://cim.ucaiug.io/ns#TC57CIM
Mappings
| Mapping Type | Mapped Value |
|---|---|
| self | cim:ACDCConverter |
| native | cim:ACDCConverter |
LinkML Source
Direct
name: ACDCConverter
description: A unit with valves for three phases, together with unit control equipment,
essential protective and switching devices, DC storage capacitors, phase reactors
and auxiliaries, if any, used for conversion.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
is_a: ConductingEquipment
attributes:
base_s:
name: base_s
description: Base apparent power of the converter pole. The attribute shall be
a positive value.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ACDCConverter.baseS
multivalued: false
domain_of:
- ACDCConverter
range: ApparentPower
required: false
idc:
name: idc
description: Converter DC current, also called Id. It is converter’s state variable,
result from power flow.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ACDCConverter.idc
multivalued: false
domain_of:
- ACDCConverter
range: CurrentFlow
required: false
idle_loss:
name: idle_loss
description: Active power loss in pole at no power transfer. It is converter’s
configuration data used in power flow. The attribute shall be a positive value.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ACDCConverter.idleLoss
multivalued: false
domain_of:
- ACDCConverter
range: ActivePower
required: false
max_p:
name: max_p
description: Maximum active power limit. The value is overwritten by values of
VsCapabilityCurve, if present.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:ACDCConverter.maxP
multivalued: false
domain_of:
- EquivalentInjection
- PowerElectronicsUnit
- ACDCConverter
- FrequencyConverter
- ExternalNetworkInjection
- GeneratorTypeAsset
range: ActivePower
required: false
max_udc:
name: max_udc
description: The maximum voltage on the DC side at which the converter should
operate. It is converter’s configuration data used in power flow. The attribute
shall be a positive value.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ACDCConverter.maxUdc
multivalued: false
domain_of:
- ACDCConverter
range: Voltage
required: false
min_p:
name: min_p
description: Minimum active power limit. The value is overwritten by values of
VsCapabilityCurve, if present.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:ACDCConverter.minP
multivalued: false
domain_of:
- EquivalentInjection
- PowerElectronicsUnit
- ACDCConverter
- FrequencyConverter
- ExternalNetworkInjection
- GeneratorTypeAsset
range: ActivePower
required: false
min_udc:
name: min_udc
description: The minimum voltage on the DC side at which the converter should
operate. It is converter’s configuration data used in power flow. The attribute
shall be a positive value.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ACDCConverter.minUdc
multivalued: false
domain_of:
- ACDCConverter
range: Voltage
required: false
number_of_valves:
name: number_of_valves
description: Number of valves in the converter. Used in loss calculations.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ACDCConverter.numberOfValves
multivalued: false
domain_of:
- ACDCConverter
range: integer
required: false
p:
name: p
description: "Active power at the point of common coupling. Load sign convention\
\ is used, i.e. positive sign means flow out from a node.\r\nStarting value\
\ for a steady state solution in the case a simplified power flow model is used."
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:ACDCConverter.p
multivalued: false
domain_of:
- EnergyGroup
- BlockDispatchOrder
- SvPowerFlow
- RotatingMachine
- EquivalentInjection
- PowerElectronicsConnection
- PowerElectronicsConnectionPhase
- ACDCConverter
- EnergyConsumerPhase
- EnergyConsumer
- ExternalNetworkInjection
- GovHydroPID2
- UnderexcLimIEEE2
- UnderexcLim2Simplified
range: ActivePower
required: false
pole_loss_p:
name: pole_loss_p
description: "The active power loss at a DC Pole \r\n= idleLoss + switchingLoss*|Idc|\
\ + resitiveLoss*Idc^2.\r\nFor lossless operation Pdc=Pac.\r\nFor rectifier\
\ operation with losses Pdc=Pac-lossP.\r\nFor inverter operation with losses\
\ Pdc=Pac+lossP.\r\nIt is converter’s state variable used in power flow. The\
\ attribute shall be a positive value."
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ACDCConverter.poleLossP
multivalued: false
domain_of:
- ACDCConverter
range: ActivePower
required: false
q:
name: q
description: "Reactive power at the point of common coupling. Load sign convention\
\ is used, i.e. positive sign means flow out from a node.\r\nStarting value\
\ for a steady state solution in the case a simplified power flow model is used."
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:ACDCConverter.q
multivalued: false
domain_of:
- SvPowerFlow
- RotatingMachine
- EquivalentInjection
- PowerElectronicsConnection
- PowerElectronicsConnectionPhase
- ACDCConverter
- EnergyConsumerPhase
- EnergyConsumer
- StaticVarCompensator
- ExternalNetworkInjection
- UnderexcLimIEEE2
- UnderexcLim2Simplified
range: ReactivePower
required: false
rated_udc:
name: rated_udc
description: Rated converter DC voltage, also called UdN. The attribute shall
be a positive value. It is converter’s configuration data used in power flow.
For instance a bipolar HVDC link with value 200 kV has a 400kV difference between
the dc lines.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:ACDCConverter.ratedUdc
multivalued: false
domain_of:
- DCConductingEquipment
- ACDCConverter
range: Voltage
required: false
resistive_loss:
name: resistive_loss
description: It is converter’s configuration data used in power flow. Refer to
poleLossP. The attribute shall be a positive value.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ACDCConverter.resistiveLoss
multivalued: false
domain_of:
- ACDCConverter
range: Resistance
required: false
switching_loss:
name: switching_loss
description: Switching losses, relative to the base apparent power 'baseS'. Refer
to poleLossP. The attribute shall be a positive value.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ACDCConverter.switchingLoss
multivalued: false
domain_of:
- ACDCConverter
range: ActivePowerPerCurrentFlow
required: false
target_ppcc:
name: target_ppcc
description: Real power injection target in AC grid, at point of common coupling. Load
sign convention is used, i.e. positive sign means flow out from a node.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ACDCConverter.targetPpcc
multivalued: false
domain_of:
- ACDCConverter
range: ActivePower
required: false
target_udc:
name: target_udc
description: Target value for DC voltage magnitude. The attribute shall be a positive
value.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ACDCConverter.targetUdc
multivalued: false
domain_of:
- ACDCConverter
range: Voltage
required: false
uc:
name: uc
description: Line-to-line converter voltage, the voltage at the AC side of the
valve. It is converter’s state variable, result from power flow. The attribute
shall be a positive value.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ACDCConverter.uc
multivalued: false
domain_of:
- ACDCConverter
- GovHydroIEEE2
- GovSteamIEEE1
- GovHydro2
- GovHydro4
- GovSteam1
- GovSteamFV3
range: Voltage
required: false
udc:
name: udc
description: Converter voltage at the DC side, also called Ud. It is converter’s
state variable, result from power flow. The attribute shall be a positive value.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ACDCConverter.udc
multivalued: false
domain_of:
- ACDCConverter
range: Voltage
required: false
valve_u:
name: valve_u
description: Valve threshold voltage, also called Uvalve. Forward voltage drop
when the valve is conducting. Used in loss calculations, i.e. the switchLoss
depend on numberOfValves * valveU0.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ACDCConverter.valveU0
multivalued: false
domain_of:
- ACDCConverter
range: Voltage
required: false
pcc_terminal:
name: pcc_terminal
description: Point of common coupling terminal for this converter DC side. It
is typically the terminal on the power transformer (or switch) closest to the
AC network.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ACDCConverter.PccTerminal
multivalued: false
domain_of:
- ACDCConverter
range: Terminal
required: false
dcterminals:
name: dcterminals
description: A DC converter have DC converter terminals. A converter has two DC
converter terminals.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:ACDCConverter.DCTerminals
multivalued: true
domain_of:
- DCNode
- DCTopologicalNode
- DCConductingEquipment
- ACDCConverter
range: ACDCConverterDCTerminal
required: false
class_uri: cim:ACDCConverter
Induced
name: ACDCConverter
description: A unit with valves for three phases, together with unit control equipment,
essential protective and switching devices, DC storage capacitors, phase reactors
and auxiliaries, if any, used for conversion.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
is_a: ConductingEquipment
attributes:
base_s:
name: base_s
description: Base apparent power of the converter pole. The attribute shall be
a positive value.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ACDCConverter.baseS
multivalued: false
alias: base_s
owner: ACDCConverter
domain_of:
- ACDCConverter
range: ApparentPower
required: false
idc:
name: idc
description: Converter DC current, also called Id. It is converter’s state variable,
result from power flow.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ACDCConverter.idc
multivalued: false
alias: idc
owner: ACDCConverter
domain_of:
- ACDCConverter
range: CurrentFlow
required: false
idle_loss:
name: idle_loss
description: Active power loss in pole at no power transfer. It is converter’s
configuration data used in power flow. The attribute shall be a positive value.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ACDCConverter.idleLoss
multivalued: false
alias: idle_loss
owner: ACDCConverter
domain_of:
- ACDCConverter
range: ActivePower
required: false
max_p:
name: max_p
description: Maximum active power limit. The value is overwritten by values of
VsCapabilityCurve, if present.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:ACDCConverter.maxP
multivalued: false
alias: max_p
owner: ACDCConverter
domain_of:
- EquivalentInjection
- PowerElectronicsUnit
- ACDCConverter
- FrequencyConverter
- ExternalNetworkInjection
- GeneratorTypeAsset
range: ActivePower
required: false
max_udc:
name: max_udc
description: The maximum voltage on the DC side at which the converter should
operate. It is converter’s configuration data used in power flow. The attribute
shall be a positive value.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ACDCConverter.maxUdc
multivalued: false
alias: max_udc
owner: ACDCConverter
domain_of:
- ACDCConverter
range: Voltage
required: false
min_p:
name: min_p
description: Minimum active power limit. The value is overwritten by values of
VsCapabilityCurve, if present.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:ACDCConverter.minP
multivalued: false
alias: min_p
owner: ACDCConverter
domain_of:
- EquivalentInjection
- PowerElectronicsUnit
- ACDCConverter
- FrequencyConverter
- ExternalNetworkInjection
- GeneratorTypeAsset
range: ActivePower
required: false
min_udc:
name: min_udc
description: The minimum voltage on the DC side at which the converter should
operate. It is converter’s configuration data used in power flow. The attribute
shall be a positive value.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ACDCConverter.minUdc
multivalued: false
alias: min_udc
owner: ACDCConverter
domain_of:
- ACDCConverter
range: Voltage
required: false
number_of_valves:
name: number_of_valves
description: Number of valves in the converter. Used in loss calculations.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ACDCConverter.numberOfValves
multivalued: false
alias: number_of_valves
owner: ACDCConverter
domain_of:
- ACDCConverter
range: integer
required: false
p:
name: p
description: "Active power at the point of common coupling. Load sign convention\
\ is used, i.e. positive sign means flow out from a node.\r\nStarting value\
\ for a steady state solution in the case a simplified power flow model is used."
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:ACDCConverter.p
multivalued: false
alias: p
owner: ACDCConverter
domain_of:
- EnergyGroup
- BlockDispatchOrder
- SvPowerFlow
- RotatingMachine
- EquivalentInjection
- PowerElectronicsConnection
- PowerElectronicsConnectionPhase
- ACDCConverter
- EnergyConsumerPhase
- EnergyConsumer
- ExternalNetworkInjection
- GovHydroPID2
- UnderexcLimIEEE2
- UnderexcLim2Simplified
range: ActivePower
required: false
pole_loss_p:
name: pole_loss_p
description: "The active power loss at a DC Pole \r\n= idleLoss + switchingLoss*|Idc|\
\ + resitiveLoss*Idc^2.\r\nFor lossless operation Pdc=Pac.\r\nFor rectifier\
\ operation with losses Pdc=Pac-lossP.\r\nFor inverter operation with losses\
\ Pdc=Pac+lossP.\r\nIt is converter’s state variable used in power flow. The\
\ attribute shall be a positive value."
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ACDCConverter.poleLossP
multivalued: false
alias: pole_loss_p
owner: ACDCConverter
domain_of:
- ACDCConverter
range: ActivePower
required: false
q:
name: q
description: "Reactive power at the point of common coupling. Load sign convention\
\ is used, i.e. positive sign means flow out from a node.\r\nStarting value\
\ for a steady state solution in the case a simplified power flow model is used."
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:ACDCConverter.q
multivalued: false
alias: q
owner: ACDCConverter
domain_of:
- SvPowerFlow
- RotatingMachine
- EquivalentInjection
- PowerElectronicsConnection
- PowerElectronicsConnectionPhase
- ACDCConverter
- EnergyConsumerPhase
- EnergyConsumer
- StaticVarCompensator
- ExternalNetworkInjection
- UnderexcLimIEEE2
- UnderexcLim2Simplified
range: ReactivePower
required: false
rated_udc:
name: rated_udc
description: Rated converter DC voltage, also called UdN. The attribute shall
be a positive value. It is converter’s configuration data used in power flow.
For instance a bipolar HVDC link with value 200 kV has a 400kV difference between
the dc lines.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:ACDCConverter.ratedUdc
multivalued: false
alias: rated_udc
owner: ACDCConverter
domain_of:
- DCConductingEquipment
- ACDCConverter
range: Voltage
required: false
resistive_loss:
name: resistive_loss
description: It is converter’s configuration data used in power flow. Refer to
poleLossP. The attribute shall be a positive value.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ACDCConverter.resistiveLoss
multivalued: false
alias: resistive_loss
owner: ACDCConverter
domain_of:
- ACDCConverter
range: Resistance
required: false
switching_loss:
name: switching_loss
description: Switching losses, relative to the base apparent power 'baseS'. Refer
to poleLossP. The attribute shall be a positive value.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ACDCConverter.switchingLoss
multivalued: false
alias: switching_loss
owner: ACDCConverter
domain_of:
- ACDCConverter
range: ActivePowerPerCurrentFlow
required: false
target_ppcc:
name: target_ppcc
description: Real power injection target in AC grid, at point of common coupling. Load
sign convention is used, i.e. positive sign means flow out from a node.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ACDCConverter.targetPpcc
multivalued: false
alias: target_ppcc
owner: ACDCConverter
domain_of:
- ACDCConverter
range: ActivePower
required: false
target_udc:
name: target_udc
description: Target value for DC voltage magnitude. The attribute shall be a positive
value.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ACDCConverter.targetUdc
multivalued: false
alias: target_udc
owner: ACDCConverter
domain_of:
- ACDCConverter
range: Voltage
required: false
uc:
name: uc
description: Line-to-line converter voltage, the voltage at the AC side of the
valve. It is converter’s state variable, result from power flow. The attribute
shall be a positive value.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ACDCConverter.uc
multivalued: false
alias: uc
owner: ACDCConverter
domain_of:
- ACDCConverter
- GovHydroIEEE2
- GovSteamIEEE1
- GovHydro2
- GovHydro4
- GovSteam1
- GovSteamFV3
range: Voltage
required: false
udc:
name: udc
description: Converter voltage at the DC side, also called Ud. It is converter’s
state variable, result from power flow. The attribute shall be a positive value.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ACDCConverter.udc
multivalued: false
alias: udc
owner: ACDCConverter
domain_of:
- ACDCConverter
range: Voltage
required: false
valve_u:
name: valve_u
description: Valve threshold voltage, also called Uvalve. Forward voltage drop
when the valve is conducting. Used in loss calculations, i.e. the switchLoss
depend on numberOfValves * valveU0.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ACDCConverter.valveU0
multivalued: false
alias: valve_u
owner: ACDCConverter
domain_of:
- ACDCConverter
range: Voltage
required: false
pcc_terminal:
name: pcc_terminal
description: Point of common coupling terminal for this converter DC side. It
is typically the terminal on the power transformer (or switch) closest to the
AC network.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ACDCConverter.PccTerminal
multivalued: false
alias: pcc_terminal
owner: ACDCConverter
domain_of:
- ACDCConverter
range: Terminal
required: false
dcterminals:
name: dcterminals
description: A DC converter have DC converter terminals. A converter has two DC
converter terminals.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:ACDCConverter.DCTerminals
multivalued: true
alias: dcterminals
owner: ACDCConverter
domain_of:
- DCNode
- DCTopologicalNode
- DCConductingEquipment
- ACDCConverter
range: ACDCConverterDCTerminal
required: false
protective_action_adjustment:
name: protective_action_adjustment
description: 'The operating condition to the Conducting Equipment is changed when
protective action adjustment is activated. For ShuntCompensator or other conducting
equipment that operates on discrete values (integer), the values given in float
will be rounded. '
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:ConductingEquipment.ProtectiveActionAdjustment
multivalued: true
alias: protective_action_adjustment
owner: ACDCConverter
domain_of:
- Measurement
- ConductingEquipment
- DCConductingEquipment
range: ProtectiveActionAdjustment
required: false
sv_status:
name: sv_status
description: The status state variable associated with this conducting equipment.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ConductingEquipment.SvStatus
multivalued: true
alias: sv_status
owner: ACDCConverter
domain_of:
- ConductingEquipment
range: SvStatus
required: false
protection_equipments:
name: protection_equipments
description: 'Protection equipment used to protect specific conducting equipment. '
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ConductingEquipment.ProtectionEquipments
multivalued: true
alias: protection_equipments
owner: ACDCConverter
domain_of:
- ConductingEquipment
range: ProtectionEquipment
required: false
base_voltage:
name: base_voltage
description: Base voltage of this conducting equipment. Use only when there is
no voltage level container used and only one base voltage applies. For example,
not used for transformers.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:ConductingEquipment.BaseVoltage
multivalued: false
alias: base_voltage
owner: ACDCConverter
domain_of:
- TopologicalNode
- TransformerEnd
- ConductingEquipment
- VoltageLevel
- AssetDeployment
range: BaseVoltage
required: false
terminals:
name: terminals
description: Conducting equipment have terminals that may be connected to other
conducting equipment terminals via connectivity nodes or topological nodes.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:ConductingEquipment.Terminals
multivalued: true
alias: terminals
owner: ACDCConverter
domain_of:
- ConnectivityNode
- ConductingEquipment
range: Terminal
required: false
jumping_action:
name: jumping_action
description: Jumper action involving jumping operation on this conducting equipment.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ConductingEquipment.JumpingAction
multivalued: false
alias: jumping_action
owner: ACDCConverter
domain_of:
- ConductingEquipment
range: JumperAction
required: false
grounding_action:
name: grounding_action
description: Action involving grounding operation on this conducting equipment.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:ConductingEquipment.GroundingAction
multivalued: false
alias: grounding_action
owner: ACDCConverter
domain_of:
- ConductingEquipment
range: GroundAction
required: false
outage:
name: outage
description: The outage that is isolated by the outage isolation equipment.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:ConductingEquipment.Outage
multivalued: false
alias: outage
owner: ACDCConverter
domain_of:
- Incident
- SwitchingPlan
- UsagePoint
- ConductingEquipment
- Crew
- EstimatedRestorationTime
- OutageArea
- Fault
range: Outage
required: false
aggregate:
name: aggregate
description: "The aggregate flag provides an alternative way of representing an\
\ aggregated (equivalent) element. It is applicable in cases when the dedicated\
\ classes for equivalent equipment do not have all of the attributes necessary\
\ to represent the required level of detail. In case the flag is set to “true”\
\ the single instance of equipment represents multiple pieces of equipment that\
\ have been modelled together as an aggregate equivalent obtained by a network\
\ reduction procedure. Examples would be power transformers or synchronous machines\
\ operating in parallel modelled as a single aggregate power transformer or\
\ aggregate synchronous machine. \r\nThe attribute is not used for EquivalentBranch,\
\ EquivalentShunt and EquivalentInjection."
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.aggregate
multivalued: false
alias: aggregate
owner: ACDCConverter
domain_of:
- Equipment
- ReadingType
range: boolean
required: false
in_service:
name: in_service
description: Specifies the availability of the equipment. True means the equipment
is available for topology processing, which determines if the equipment is energized
or not. False means that the equipment is treated by network applications as
if it is not in the model.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.inService
multivalued: false
alias: in_service
owner: ACDCConverter
domain_of:
- Equipment
- SvStatus
- ProtectiveActionEquipment
range: boolean
required: false
network_analysis_enabled:
name: network_analysis_enabled
description: The equipment is enabled to participate in network analysis. If
unspecified, the value is assumed to be true.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.networkAnalysisEnabled
multivalued: false
alias: network_analysis_enabled
owner: ACDCConverter
domain_of:
- Equipment
range: boolean
required: false
normally_in_service:
name: normally_in_service
description: Specifies the availability of the equipment under normal operating
conditions. True means the equipment is available for topology processing, which
determines if the equipment is energized or not. False means that the equipment
is treated by network applications as if it is not in the model.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.normallyInService
multivalued: false
alias: normally_in_service
owner: ACDCConverter
domain_of:
- Equipment
range: boolean
required: false
weather_station:
name: weather_station
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.WeatherStation
multivalued: true
alias: weather_station
owner: ACDCConverter
domain_of:
- Equipment
range: WeatherStation
required: false
operational_limit_set:
name: operational_limit_set
description: The operational limit sets associated with this equipment.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:Equipment.OperationalLimitSet
multivalued: true
alias: operational_limit_set
owner: ACDCConverter
domain_of:
- ACDCTerminal
- OperationalLimit
- Equipment
range: OperationalLimitSet
required: false
contingency_equipment:
name: contingency_equipment
description: The contingency equipments in which this equipment participates.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.ContingencyEquipment
multivalued: true
alias: contingency_equipment
owner: ACDCConverter
domain_of:
- Equipment
range: ContingencyEquipment
required: false
equipment_container:
name: equipment_container
description: Container of this equipment.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.EquipmentContainer
multivalued: false
alias: equipment_container
owner: ACDCConverter
domain_of:
- Equipment
range: EquipmentContainer
required: false
faults:
name: faults
description: All faults on this equipment.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.Faults
multivalued: true
alias: faults
owner: ACDCConverter
domain_of:
- Equipment
- Outage
- FaultCauseType
range: Fault
required: false
limit_dependency_model:
name: limit_dependency_model
description: Limit dependencymodels organized under this equipment as a means
for organizing the model in a tree view.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
slot_uri: cim:Equipment.LimitDependencyModel
multivalued: true
alias: limit_dependency_model
owner: ACDCConverter
domain_of:
- OperationalLimit
- Equipment
range: LimitDependency
required: false
eqiupment_limit_series_component:
name: eqiupment_limit_series_component
description: Equipment limit series calculation component to which this equipment
contributes.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.EqiupmentLimitSeriesComponent
multivalued: true
alias: eqiupment_limit_series_component
owner: ACDCConverter
domain_of:
- Equipment
range: EquipmentLimitSeriesComponent
required: false
protective_action_equipment:
name: protective_action_equipment
description: Protective action is controlling equipment. This can be direct signals
from the control center, or emulation of action done by protection equipment.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.ProtectiveActionEquipment
multivalued: true
alias: protective_action_equipment
owner: ACDCConverter
domain_of:
- Equipment
range: ProtectiveActionEquipment
required: false
pin_equipment:
name: pin_equipment
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.PinEquipment
multivalued: true
alias: pin_equipment
owner: ACDCConverter
domain_of:
- Equipment
range: PinEquipment
required: false
equipment_unavailability_schedule:
name: equipment_unavailability_schedule
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.EquipmentUnavailabilitySchedule
multivalued: true
alias: equipment_unavailability_schedule
owner: ACDCConverter
domain_of:
- Equipment
- UnavailabilitySwitchAction
- UnavailablitySchedule
range: EquipmentUnavailabilitySchedule
required: false
additional_equipment_container:
name: additional_equipment_container
description: Additional equipment container beyond the primary equipment container. The
equipment is contained in another equipment container, but also grouped with
this equipment container.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.AdditionalEquipmentContainer
multivalued: true
alias: additional_equipment_container
owner: ACDCConverter
domain_of:
- Equipment
range: EquipmentContainer
required: false
usage_points:
name: usage_points
description: All usage points connected to the electrical grid through this equipment.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.UsagePoints
multivalued: true
alias: usage_points
owner: ACDCConverter
domain_of:
- Equipment
- CustomerAgreement
- ServiceCategory
- PricingStructure
- EndDeviceControl
- UsagePointGroup
- ServiceLocation
- MetrologyRequirement
- ServiceSupplier
- UsagePointLocation
range: UsagePoint
required: false
outages:
name: outages
description: All outages in which this equipment is involved.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.Outages
multivalued: true
alias: outages
owner: ACDCConverter
domain_of:
- Equipment
range: Outage
required: false
operational_restrictions:
name: operational_restrictions
description: All operational restrictions for this equipment.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:Equipment.OperationalRestrictions
multivalued: true
alias: operational_restrictions
owner: ACDCConverter
domain_of:
- Equipment
- ProductAssetModel
range: OperationalRestriction
required: false
controls:
name: controls
description: The controller outputs used to actually govern a regulating device,
e.g. the magnetization of a synchronous machine or capacitor bank breaker actuator.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.Controls
multivalued: true
alias: controls
owner: ACDCConverter
domain_of:
- PowerSystemResource
- HostControlArea
range: Control
required: false
measurements:
name: measurements
description: The measurements associated with this power system resource.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.Measurements
multivalued: true
alias: measurements
owner: ACDCConverter
domain_of:
- PowerSystemResource
- ACDCTerminal
- Asset
- Location
- Procedure
- AnalogLimitSet
- AccumulatorLimitSet
range: Measurement
required: false
psrtype:
name: psrtype
description: Custom classification for this power system resource.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.PSRType
multivalued: false
alias: psrtype
owner: ACDCConverter
domain_of:
- PowerSystemResource
range: PSRType
required: false
configuration_event:
name: configuration_event
description: All configuration events created for this Power System resource.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.ConfigurationEvent
multivalued: true
alias: configuration_event
owner: ACDCConverter
domain_of:
- PowerSystemResource
- FaultCauseType
range: ConfigurationEvent
required: false
reporting_group:
name: reporting_group
description: Reporting groups to which this power system resource belongs.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.ReportingGroup
multivalued: true
alias: reporting_group
owner: ACDCConverter
domain_of:
- PowerSystemResource
- BusNameMarker
- TopologicalNode
- ReportingSuperGroup
range: ReportingGroup
required: false
operating_share:
name: operating_share
description: The operating shares of this power system resource.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.OperatingShare
multivalued: true
alias: operating_share
owner: ACDCConverter
domain_of:
- PowerSystemResource
- OperatingParticipant
range: OperatingShare
required: false
asset_datasheet:
name: asset_datasheet
description: Datasheet information for this power system resource.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.AssetDatasheet
multivalued: false
alias: asset_datasheet
owner: ACDCConverter
domain_of:
- PowerSystemResource
range: AssetInfo
required: false
verification_action:
name: verification_action
description: The verification action that is performed on the power system resource
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.VerificationAction
multivalued: true
alias: verification_action
owner: ACDCConverter
domain_of:
- PowerSystemResource
range: VerificationAction
required: false
clearances:
name: clearances
description: All clearances applicable to this power system resource.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.Clearances
multivalued: true
alias: clearances
owner: ACDCConverter
domain_of:
- PowerSystemResource
range: ClearanceDocument
required: false
generic_action:
name: generic_action
description: The generic action that is performed on the power system resource
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.GenericAction
multivalued: true
alias: generic_action
owner: ACDCConverter
domain_of:
- PowerSystemResource
range: GenericAction
required: false
psrevents:
name: psrevents
description: All events associated with this power system resource.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.PSREvents
multivalued: true
alias: psrevents
owner: ACDCConverter
domain_of:
- PowerSystemResource
range: PSREvent
required: false
assets:
name: assets
description: All assets represented by this power system resource. For example,
multiple conductor assets are electrically modelled as a single AC line segment.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.Assets
multivalued: true
alias: assets
owner: ACDCConverter
domain_of:
- PowerSystemResource
- AssetInfo
- Location
- WorkTask
- ErpRecDelvLineItem
- AssetContainer
- ActivityRecord
- Procedure
- ReliabilityInfo
- AssetPropertyCurve
- AssetOrganisationRole
- ScheduledEvent
range: Asset
required: false
location:
name: location
description: Location of this power system resource.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.Location
multivalued: false
alias: location
owner: ACDCConverter
domain_of:
- PowerSystemResource
- Asset
- Incident
- SwitchingOrder
- TroubleOrder
- Crew
- Fault
- PointOfSale
- TroubleTicket
- OutageOrder
- EnvironmentalMonitoringStation
- EnvironmentalLocationType
- PositionPoint
- FailureEvent
range: Location
required: false
operational_tags:
name: operational_tags
description: All operational tags placed on this power system resource.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:PowerSystemResource.OperationalTags
multivalued: true
alias: operational_tags
owner: ACDCConverter
domain_of:
- PowerSystemResource
- Asset
range: OperationalTag
required: false
alias_name:
name: alias_name
description: "The aliasName is free text human readable name of the object alternative\
\ to IdentifiedObject.name. It may be non unique and may not correlate to a\
\ naming hierarchy.\r\nThe attribute aliasName is retained because of backwards\
\ compatibility between CIM relases. It is however recommended to replace aliasName\
\ with the Name class as aliasName is planned for retirement at a future time.\r\
\n\r\n"
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.aliasName
multivalued: false
alias: alias_name
owner: ACDCConverter
domain_of:
- IdentifiedObject
range: string
required: false
description:
name: description
description: The description is a free human readable text describing or naming
the object. It may be non unique and may not correlate to a naming hierarchy.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.description
multivalued: false
alias: description
owner: ACDCConverter
domain_of:
- IdentifiedObject
- NameType
- NameTypeAuthority
- DataSet
- SwitchingStepGroup
- AreaReserveSpec
range: string
required: false
m_rid:
name: m_rid
description: "Master resource identifier issued by a model authority. The mRID\
\ is unique within an exchange context. Global uniqueness is easily achieved\
\ by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is\
\ strongly recommended.\r\nFor CIMXML data files in RDF syntax conforming to\
\ IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify\
\ CIM object elements."
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.mRID
multivalued: false
alias: m_rid
owner: ACDCConverter
domain_of:
- IdentifiedObject
- DataSet
range: string
required: false
diagram_objects:
name: diagram_objects
description: The diagram objects that are associated with the domain object.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.DiagramObjects
multivalued: true
alias: diagram_objects
owner: ACDCConverter
domain_of:
- IdentifiedObject
range: DiagramObject
required: false
instance_set:
name: instance_set
description: Dataset containing the data objects.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.InstanceSet
multivalued: false
alias: instance_set
owner: ACDCConverter
domain_of:
- IdentifiedObject
range: InstanceSet
required: true
names:
name: names
description: All names of this identified object.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.Names
multivalued: true
alias: names
owner: ACDCConverter
domain_of:
- IdentifiedObject
- NameType
range: Name
required: false
properties_cimdata_object:
name: properties_cimdata_object
description: The single CIM data object in the appropriate dataset context.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.PropertiesCIMDataObject
multivalued: false
alias: properties_cimdata_object
owner: ACDCConverter
domain_of:
- IdentifiedObject
range: ChangeSetMember
required: false
targeting_cimdata_object:
name: targeting_cimdata_object
description: Data objects registered.
from_schema: https://cim.ucaiug.io/ns#TC57CIM
rank: 1000
slot_uri: cim:IdentifiedObject.TargetingCIMDataObject
multivalued: true
alias: targeting_cimdata_object
owner: ACDCConverter
domain_of:
- IdentifiedObject
range: ChangeSetMember
required: false
class_uri: cim:ACDCConverter