| a |
Turbine power time constant numerator scale factor (a) |
| a_dlogic_kind |
The compare operation |
| a_vrdelay |
An automatic voltage regulation delay (AVRDelay) which is the time delay from... |
| a_vrto_manual_lag |
Time delay required when switching from Automatic Voltage Regulation (AVR) to... |
| a_vrto_manual_lead |
Time delay required when switching from Automatic Voltage Regulation (AVR) to... |
| absolute_value |
If true, use the absolute value for compare |
| acaflag |
Indication that this resource is associated with an Adjacent Control Area |
| accept_comments |
Commenst to explain why the acceptance status |
| accept_mw |
The accepted mw amount by the responder |
| accept_status |
The accept status submitted by the responder |
| acceptable_duration |
The nominal acceptable duration of the limit |
| acceptance_test |
Information on acceptance test |
| access_method |
Method for the service person to access this service location |
| access_priviledge |
Provides information regarding the access privileges allowed to the ICCP Poin... |
| according_to_schedules |
|
| account |
The account to which this actual material item is charged |
| account_holder_name |
Name of account holder |
| account_id |
Account identifier for this entry |
| account_kind |
Kind of account for this entry |
| account_notification |
The notification for the customer account |
| account_number |
Operational account reference number |
| accounting_usage |
A code that identifies appropriate type of property accounts such as distribu... |
| accumulation |
Accumulation behaviour of a reading over time, usually 'measuringPeriod', to ... |
| accumulator |
Measurement to which this value is connected |
| accumulator_reset |
The command that resets the accumulator value |
| accumulator_value |
The accumulator value that is reset by the command |
| accumulator_values |
The values connected to this measurement |
| accuracy_class |
CT accuracy classification |
| accuracy_limit |
Percent of rated current for which the CT remains accurate within specified l... |
| ace_tariff_type |
|
| acline_segment |
The line segment to which the clamp is connected |
| acline_segment_phase |
AC line segment phase information associated with this wire information |
| acline_segment_phases |
The line segment phases which belong to the line segment |
| acline_segments |
The line segment that this jumper action will affect |
| action |
Buy, Sell |
|
|
| action_name |
Action name type for the action request |
| action_recommendation |
Recommendation for action |
| action_request |
|
| action_timeline |
Time horizon for action |
| active_period |
Interval during which this restriction is applied |
| active_power |
High voltage source active injection |
| active_power_uom |
The unit of measure of active power, e |
| active_storage_capacity |
Storage volume between the full supply level and the normal minimum operating... |
| activity_code |
Activity code identifies a specific and distinguishable unit of work |
| activity_interval |
Interval for activity of this shift |
| activity_record |
The activity record for a document |
| activity_records |
All activity records created for this asset |
| actual_demand_response_event |
ActualDemandResponseEvents may exist that are not part of a cordinated Market... |
| actual_end |
Market ending time - actual market end |
|
|
| actual_mw |
Actual branch or group of branches MW flow (only for transmission constraints... |
| actual_period |
Actual outage period; end of the period corresponds to the actual restoration... |
| actual_purchase_cost |
The actual purchase cost of this particular asset |
| actual_ramp_rate |
Actual ramp rate |
| actual_start |
Market starting time - actual market start |
|
|
| actuator_maximum |
The maximum set point value accepted by the remote control point |
| actuator_minimum |
The minimum set point value accepted by the remote control point |
| additional_equipment_container |
Additional equipment container beyond the primary equipment container |
| additional_grouped_equipment |
The additonal contained equipment |
| address |
Is the dotted decimal IP Address resolve the IP address |
| address_general |
(if applicable) Third line of a free form address |
| address_type |
IP address type |
| adjacent_caset |
|
| adjslew |
Rate at which output of adjuster changes (ADJ_SLEW) |
| adjusted_amount |
|
| adjusted_trade_quantity |
The validated and current market accepted trade amount of a physical energy t... |
| ae |
Major loop PI tag gain factor (Ae) |
| ae_invoke |
Is part of the Application Entity addressing as specified by ISO Addressing |
| ae_qual |
Is the AE qualifier and represents further application level addressing infor... |
| af |
Coefficient equal to 0,5(1-speed) (Af2) |
| aggregate |
The aggregate flag provides an alternative way of representing an aggregated ... |
| aggregate_node |
An AggregateNode may be associated with up to many RegisteredResources |
| aggregate_type |
"1" -- "Detail", |
|
|
| aggregated_pnode |
|
| aggregation_flag |
Aggregation flag |
|
|
| ai |
Minor loop PI tag gain factor (Ai) |
| air_compressor |
An air compressor may be a member of a compressed air energy storage plant |
| air_compressor_rating |
Rating of the CAES air compressor |
| al |
Limiter (Al) |
| alert_type |
The type of the issued alert which is drawn from the specified alert type lis... |
| alert_type_list |
The list of alert types from which the type of this alert is drawn |
| alias_name |
The aliasName is free text human readable name of the object alternative to I... |
| alloc_spin_res_p |
The planned unused capacity (spinning reserve) which can be used to support e... |
| allocation_mode |
Identification of the method of allocation in an auction |
| allocation_mw_hour |
|
| allocation_price |
|
| allocation_result |
|
| allocation_result_values |
|
| along_acline_segment |
The line segment that this ground action will affect |
| alpha |
Firing angle that determines the dc voltage at the converter dc terminal |
| alt_generating_unit |
The alternate generating unit for which this measurement value applies |
| alt_generating_unit_meas |
The link to prioritized measurements for this GeneratingUnit |
| alt_tie_meas |
The usage of the measurement within the control area specification |
| alternate_cost_delivered |
Alternative measure of the cost of the energy consumed |
| alternate_cost_unit |
Cost unit for the alternate cost delivered field |
| alternate_model |
The alternate model using the data |
| alternate_model_group |
The group of alternate models for which one alternate is used |
| altitude |
The maximum altitude of the phenomenon |
| am |
Opening section SEFF at the maximum efficiency (A... |
| ambient_temp |
Default ambient temperature to be used in modelling applications |
| ambient_temperature_at_sampling |
Operating ambient temperature (in °C) |
| ami_billing_ready |
Tracks the lifecycle of the metering installation at a usage point with respe... |
| amount |
The amount of the debit or credit for this account |
| amount_assignable |
True if an amount can be assigned to the resource element (e |
| amr_address |
Communication ID number (e |
| amr_router |
Communication ID number (e |
| amr_system |
Automated meter reading (AMR) or other communication system responsible for c... |
| analog |
Measurement to which this value is connected |
| analog_control |
The Control variable associated with the MeasurementValue |
| analog_value |
The specific analog value used as a source |
| analog_values |
The values connected to this measurement |
| analytic |
Analytic performed on this asset |
| analytic_score |
Analytic result related to this asset |
| anchor_kind |
(if anchor) Kind of anchor |
| anchor_rod_count |
(if anchor) Number of rods used |
| anchor_rod_length |
(if anchor) Length of rod used |
| ancillary_service_clearing |
|
| ancillary_svc_cost |
Total AS Cost (i |
| angle |
The voltage angle of the topological node complex voltage with respect to sys... |
| angle_ref_topological_island |
The island for which the node is an angle reference |
| angle_ref_topological_node |
The angle reference for the island |
| angle_regulation_status |
True means the phase shifter is regulating |
| anode_type |
Type of aggregated node |
|
|
| answer |
Answer to question |
| answer_date_time |
The date and time the quesiton was answered |
| answer_remark |
Remarks to qualify the answer |
| ap_invoke |
Is a further application level OSI addressing parameter |
| ap_title |
Is a sequence of integer strings separated by " |
| apnode_type |
Aggregate Price Node Types |
|
|
| appliance |
Appliance being controlled |
| application_number |
Permit application number that is used by municipality, state, province, etc |
| application_period |
Period in which this service guantee applies |
| application_security_requirement |
Specifies the expected security mechanism, per IEC 62351-4, to be utilized |
| applied_date_time |
Date and time this seal has been applied |
| appointment_requested |
|
| appointments |
All appointments for this person |
| approved_date_time |
The date and time the switching plan was approved |
| approver |
Approver of this document |
| apss |
Coefficient (a_PSS) |
| area_code |
(if applicable) Area or region code |
| area_control_mode |
The area's present control mode: (CF = constant frequency) or (CTL = constant... |
| area_load_bid |
|
| area_load_curve |
|
| area_reserve_specification |
|
| area_short_name |
Market area short name, which is the regulation zone |
| argument |
Argument used to introduce numbers into the unit of measure description where... |
| arm_length |
Length of arm |
| armed |
The status of the class set by operation or by signal |
| armed_timeout |
Setting of the timeout elapsed time |
| arrears |
Part of 'current' that constitutes the arrears portion |
| arrears_interest |
The interest per annum to be charged prorata on 'AuxiliaryAccount |
| aset |
Acceleration limiter setpoint (Aset) |
| asrequirements |
|
| assc_type |
association type for the association between Organisation and Resource: |
| assembly_description |
The assembly description into which model parts should be included |
| assembly_manifest |
|
| asset |
The asset to which this financial information relates |
| asset_aggregate_score |
Aggregate score to which this analytic score contributed |
| asset_analog |
An asset health analog related to this lab test standard |
| asset_container |
Container of this asset |
| asset_containers |
|
| asset_datasheet |
Datasheet information for this power system resource |
| asset_deployment |
This asset's deployment |
| asset_discrete |
An asset health discrete related to this lab test standard |
| asset_function |
Function performed by this asset |
| asset_group |
Asset group of which this asset is a part |
| asset_health_event |
Asset health event which can be generated by this analytic |
| asset_health_score |
Individual health score associated with this risk score |
| asset_info |
Data applicable to this asset |
| asset_model |
|
| asset_model_catalogue |
|
| asset_model_catalogue_item |
|
| asset_model_catalogue_items |
|
| asset_owner |
Asset owner that is subject in this ownership |
| asset_properites |
UserAttributes used to specify further properties of the asset covered with t... |
| asset_property_curves |
|
| asset_risk_score |
Risk score with which this health score is associated |
| asset_string |
An asset health string related to this lab test standard |
| asset_test_lab |
Test lab which produced this set of lab test results |
| asset_test_sample_taker |
Test sampler taker who gathered this specimen |
| assets |
All assets represented by this power system resource |
| assignment_type |
Type of assignement intended to be worked on this shift, for example, tempora... |
| assignments |
All Assignments for this Crew |
| asspoptimization_flag |
Indication that the resource participates in the optimization process by defa... |
| asynchronous_machine |
Asynchronous machine to which this asynchronous machine dynamics model applie... |
| asynchronous_machine_dynamics |
Asynchronous machine model with which this wind generator type 1 or type 2 mo... |
| asynchronous_machine_type |
Indicates the type of Asynchronous Machine (motor or generator) |
| asynchronous_machine_user_defined |
Proprietary user-defined model with which this parameter is associated |
| at |
Ambient temperature load limit (Load Limit) |
| athres |
Threshold value above which output averaging will be bypassed (Athres) |
| atr |
AVR constant (Atr) |
| attained |
Attained |
| attribute |
The identification of the formal name of an attribute |
| attribute_instance_component |
|
| attribute_property |
|
| attribute_value |
The instance value of the attribute |
| aturb |
Turbine numerator multiplier (Aturb) |
| atw |
Factor multiplying Tw (Atw) |
| auction |
|
| author |
Author of this document |
| author_name |
Name of the author of this document |
| auto_cntrl_margin_p |
The planned unused capacity which can be used to support automatic control ov... |
| automatic_pay |
True if utility must autmatically pay the specified amount whenever the condi... |
| autonomous_dst |
True if autonomous DST (daylight saving time) function is supported |
| aux_cycle |
The frequency for automatically recurring auxiliary charges, where 'Auxiliary... |
| aux_power_mult |
Power output - auxiliary power multiplier adjustment factor |
| aux_power_offset |
Power output - auxiliary power offset adjustment factor |
| aux_power_versus_frequency |
Off-nominal frequency effect on turbine auxiliaries |
| aux_power_versus_voltage |
Off-nominal voltage effect on turbine auxiliaries |
| aux_priority_code |
The coded priority indicating the priority that this auxiliary agreement has ... |
| auxiliary_account |
Auxiliary account for this payment transaction |
| auxiliary_accounts |
All auxiliary accounts regulated by this agreement |
| auxiliary_agreement |
Auxiliary agreement regulating this account |
| auxiliary_agreements |
All (non-service related) auxiliary agreements that refer to this customer ag... |
| auxiliary_equipment |
The auxiliary equipment connected to the terminal |
| auxillary_cost |
|
| auxillary_data |
|
| auxillary_object |
|
| auxillary_values |
|
| av |
Area of the compensation tank (AV1) |
| avail_transfer_capability |
The available transmission capability of a transmission path for the referenc... |
| avail_undispatched_q |
|
| availablity_plan |
|
| avg_load_adjustment |
Used to define a maximum energy usage limit as a percentage of the client imp... |
| award_mw |
For DA Energy: Not Applicable; |
|
|
| b |
Zero sequence magnetizing branch susceptance |
| b_ch |
Zero sequence mutual coupling shunt (charging) susceptance, uniformly distrib... |
| b_per_section |
Positive sequence shunt (charging) susceptance per section |
| bad_reference |
Measurement value may be incorrect due to a reference being out of calibratio... |
| balance |
The total amount currently remaining on this account that is required to be p... |
| balancing_flag |
This is a Y/N flag for a self-schedule of a resource per market per date and ... |
| bank |
Bank that provides this BankAccount |
| bank_aba |
Bank ABA |
| bank_account_detail |
Details of the account holder and bank |
| bank_accounts |
All BackAccounts this ServiceSupplier owns |
| bank_name |
Name of bank where account is held |
| base |
The base altitude of the phenomenon |
| base_case_constraint_limit |
|
| base_energy |
Quantity, typically MWs - Seller owns all rights being offered, MWs over time... |
| base_flow |
Branch base Power Flow |
| base_kind |
Kind of base for this pole |
| base_mw |
Net Actual MW Flow |
|
|
| base_p |
For dispatchable units, this value represents the economic active power basep... |
| base_power |
Base power at which the tests are conducted, usually equal to the rateds of o... |
| base_q |
Default base reactive power value |
| base_s |
Base apparent power of the converter pole |
| base_voltage |
The base voltage of the topological node |
| base_work |
Time schedule for this work or work task |
| base_works |
All works/tasks at this location |
| battery_state |
The current state of the battery (charging, full, etc |
| bay_energy_meas_flag |
Indicates the presence/absence of energy measurements |
| bay_power_meas_flag |
Indicates the presence/absence of active/reactive power measurements |
| bays |
The bays within this voltage level |
| bca |
Acceleration limit set-point (Bca) |
| bch |
Positive sequence shunt (charging) susceptance, uniformly distributed, of the... |
| before_sh_circuit_highest_operating_current |
The highest operating current (Ib in IEC 60909-0) before short circuit (depen... |
| before_sh_circuit_highest_operating_voltage |
The highest operating voltage (Ub in IEC 60909-0) before short circuit |
| before_short_circuit_angle_pf |
The angle of power factor before short circuit (phib in IEC 60909-0) |
| best_value |
Value that indicates best possible numeric value |
| bf |
Turbine torque coefficient Khhv (depends on heating value of fuel ... |
| bglimit |
This value is determined in DA and RTM |
| bgtrres_cap |
Branch Group TR Reservation Capacity - This value is determined in DA and RTM |
| bgv |
Kaplan blade servo point 5 (Bgv5) (= 0 for simple, = 0 for Francis/Pel... |
| bic |
Bank identifier code as defined in ISO 9362; for use in countries wher IBAN i... |
| bid |
|
| bid_amount |
The amount that a given contractor will charge for performing this unit of wo... |
| bid_ceiling |
Bid Ceiling ($/MWH) |
|
|
| bid_ceiling_as |
Bid Ceiling ($/MWH) for generic AS versus a specific market product |
|
|
| bid_distribution_factor |
|
| bid_error |
|
| bid_floor |
Bid Floor, ($/MWH) |
|
|
| bid_floor_as |
Bid Floor ($/MWH) for generic AS versus a specific market product |
|
|
| bid_hourly_product_schedule |
|
| bid_hourly_schedule |
|
| bid_price |
Bid price associated with contract |
|
|
| bid_price_cap |
|
| bid_price_curve |
|
| bid_schedule |
|
| bid_segment_calc_type |
Type of calculation basis used to define the default bid segment curve |
| bid_self_sched |
|
| bid_set |
|
| bid_status |
|
| bid_type |
bidType has two types as the required output of requirements and qualified pr... |
| bids |
|
| bil |
Basic Insulation Level (BIL) expressed as the impulse crest voltage of a nomi... |
| bilateral_exchange_actor |
Remote peer that will receive ICCP information in a Bilateral table |
| bilateral_table_id |
Specifies the version of the Bilateral Table configuration that is being exch... |
| bilateral_table_version |
The Version attribute identifies a unique version of the Bilateral Table |
| bilateral_to_iopoint |
Bilateral ICCP point for the measurement or control |
| bill_determinant |
|
| bill_determinants |
A BillDeterminant can have 0-n ChargeComponent and a ChargeComponent can asso... |
| bill_end |
Bill period end date |
|
|
| bill_media_kind |
Kind of media by which the CustomerBillingInfo was delivered |
| bill_period |
Bill period for the line item |
| bill_run_type |
The settlement run type, for example: prelim, final, and rerun |
| bill_start |
Bill period start date |
|
|
| billed_to |
The company to which the PTB transaction is billed |
| billing_cycle |
Cycle day on which the associated customer account will normally be billed, u... |
| billing_date |
Business date designated for the billing run which produced this CustomerBill... |
| binding_dod |
Binding dispatch operating delta provides a relative delta to be applied |
| binding_dot |
|
| binding_instruction |
|
| binding_limit |
MW Limit |
| blint |
Governor control flag (BLINT) |
| block |
(if applicable) Name, identifier, or description of the block in which work i... |
| block_bid |
Indication that the values in the period are considered as a whole |
| block_dispatch_component |
|
| block_dispatch_instruction |
|
| block_dispatch_order |
|
| block_load_transfer |
Emergency operating procedure - Flag to indicate that the Resource is Block L... |
| blocked_dispatch |
Blocked Dispatch Indicator (Yes/No) |
|
|
| blocked_publish_dop |
Block sending DOP to ADS (Y/N) |
|
|
| blocking_function |
|
| bmag_sat |
Core shunt magnetizing susceptance in the saturation region |
| bmax |
Maximum blade adjustment factor (Bmax) (= 0 for simple, = 0 for Franc... |
| boiler_control_mode |
The control mode of the boiler |
| boolean_parameter_value |
Boolean parameter value |
| bp |
Droop (bp) |
| branch_code |
Branch of bank where account is held |
| branch_direct |
For VAR, amp, or power factor locally controlled shunt impedances, the flow d... |
| branch_group |
The branch group to which the directed branch group terminals belong |
| branch_group_terminal |
The directed branch group terminals for which this terminal is monitored |
| breaker |
Breaker asset to which this operation information applies |
| breaker_application |
Type of network role breaker is playing in this deployment (applies to breake... |
| breaker_configuration |
Breaker configuration |
| breaker_failure_reason |
Reason for breaker failure |
| breaker_maintenance_kind |
Kind of breaker maintenance performed by this maintenance work task |
| breaker_operation |
Breaker operation information for this breaker |
| breaker_repair_item |
Breaker component or problem area which is the focus of this maintenance work... |
| breaking_capacity |
The maximum fault current a breaking device can break safely under prescribed... |
| breast_block |
True if a block of material has been attached to base of pole in ground for s... |
| bs |
Steady state voltage index for reactive power (BS) |
| bt |
Transient voltage index for reactive power (BT) |
| bturb |
Turbine denominator multiplier (Bturb) (> 0) |
| budget |
Overall project budget |
| budget_bill |
Budget bill code |
| building_name |
(if applicable) In certain cases the physical location of the place of intere... |
| building_number |
Number of building where location is |
| bus_bar_configuration |
Busbar configuration |
| bus_fed_selector |
Fed by selector (BusFedSelector) |
| bus_name_marker |
The bus name markers that belong to this reporting group |
| busbar_section |
A VoltageControlZone is controlled by a designated BusbarSection |
| bushing |
|
| bushing_insulation_pfs |
|
| bushing_insultation_pfs |
|
| bushing_temp |
Bushing temperature |
| business_case |
|
| business_type |
The identification of the nature of the time series |
| bwh |
Notch filter 2 (high-frequency band): three dB bandwidth (Bwi<... |
| bwl |
Notch filter 2 (low-frequency band): three dB bandwidth (Bwi</... |
| by_mkt_measurement |
A measurement is made on the B side of a tie point |
| by_percentage |
The adjustment is given in percent of the active value |
| by_tie_point |
A measurement is made on the B side of a tie point |
| by_value |
The adjustment is given in value of the active value |
| c |
Valve positioner (C) |
| c_capacitance |
Factory measured capacitance measured between the power factor tap and ground |
| c_power_factor |
Factory measured insulation power factor, measured between the power factor t... |
| c_rrcategory |
CRR category represents 'PTP' for a point-to-point CRR, or 'NSR' for a Networ... |
| c_rrtype |
Type of the CRR, from the possible type definitions in the CRR System (e |
| cachild_of |
A ControlAreaOperator has a collection of tie points that ring the ControlAre... |
| caesplant |
A thermal generating unit may be a member of a compressed air energy storage ... |
| calc_load_following_mw |
weighted average for RTPD and RTCD and same for RTID |
|
|
| calculation_date_time |
Timestamp of when the score was calculated |
| calculation_interval_magnitude |
Number of units (of calculationIntervalUnit) in the calculation interval |
| calculation_interval_unit |
Unit in which calculation interval is defined |
| calculation_level |
Level in charge calculation order |
| calculation_method_hierarchy |
|
| calculation_method_order |
Order of a statistical calculation associated with this calculation method hi... |
| calculation_mode |
Calculation mode |
| calculation_technique |
Kind of statistical calculation, specifying how the measurement value is calc... |
| call_ahead |
True if requested to call customer when someone is about to arrive at their p... |
| calling |
Used to indicate if the Provider is responsible for initiating the TASE |
| cancel_control_mode |
Encoding of cancel control |
| cancel_date_time |
Timestamp when a canceling of the event is scheduled to start |
| cancel_now |
If true, a canceling of the event should start immediately |
| cancelled |
An indicator that signifies that the auction has been cancelled |
| cancelled_date_time |
Date and Time the switching plan was cancelled |
| cancelled_ts |
An indicator stating that the TimeSeries, identified by the mRID, is cancelle... |
| capabilities |
|
| capability |
Inherent capabilities of the device (i |
| capability_curve |
Capability curve of this converter |
| capability_versus_frequency |
Off-nominal frequency effect on turbine capability |
| capacitance |
Capacitance of the DC line segment |
| capacitive_rating |
Capacitive reactance at maximum capacitive reactive power |
| capacity_backed |
Interchange capacity flag |
| capacity_benefit_margin |
Capacity Benefit Margin (CBM) is used by Markets to calculate the transmissio... |
| capacity_factor |
The ratio of actual energy produced by resource divided by the maximum potent... |
| capacity_level |
Capacity level for the profile, in MW |
| capacity_type |
capacity type |
|
|
| card |
Card used to tender payment |
| case_type |
Settlement period: |
|
|
| cash_float |
The amount of cash that the cashier brings to start the shift and that will b... |
| cashier |
Cashier operating this shift |
| cashier_shift |
Cashier shift during which this transaction was recorded |
| cashier_shifts |
All shifts operated by this cashier |
| catalog_asset_type |
Asset information (nameplate) for this catalog asset type |
| catalogue_number |
Catalogue number for asset model |
| category |
High-level nature of the reading value quality |
| cause |
Cause of this incident |
| cause_kind |
The possible cause that could be associated with this unplanned outage |
| ccainverter |
|
| ccarectifier_control |
|
| cdrt |
Drive train damping (cdrt) |
| cell_size |
The size of the individual units that make up the bank |
| central_pressure |
The central pressure of the cyclone during the time interval |
| certification_name |
The Subject DN is the X509 Certificate Subject DN |
| certification_period |
Interval between the certification and its expiry |
| cf |
Coefficient defining fuel flow where power output is 0% (Cf2) |
| cf_value |
The actual value of the condition factor, such as labor flat fee or percentag... |
| chain_contract_right |
|
| chain_order |
When used in conjunction with a Transmission Right contract chain, this is th... |
| chain_transmission_right_chain |
|
| change |
Difference between amount tendered by customer and the amount charged by poin... |
| change_dst |
Change in the disturbance - storm time (Dst) index |
| change_set |
The details of model changes for this project |
| change_set_member |
Data objects contained in the dataset |
| change_sets |
|
| change_type |
Type of operational updated rating, e |
| changed_asset |
Asset whose change resulted in this configuration event |
| changed_document |
Document whose change resulted in this configuration event |
| changed_location |
Location whose change resulted in this configuration event |
| changed_organisation_role |
Organisation role whose change resulted in this configuration event |
| changed_person_role |
Person role whose change resulted in this configuration event |
| changed_service_category |
Service category whose change resulted in this configuration event |
| changed_usage_point |
Usage point whose change resulted in this configuration event |
| changeset |
Dataset containing the data objects |
| changeset_version |
|
| channel |
Channel reporting/collecting register values with this type information |
| channels |
All channels that collect/report values from this register |
| charge_components |
A ChargeType can have 0-n ChargeComponent and a ChargeComponent can associate... |
| charge_group |
A ChargeGroup can have 0-n ChargeType |
| charge_group_child |
A ChargeGroup instance can have relationships with other ChargeGroup instance... |
| charge_group_parent |
A ChargeGroup instance can have relationships with other ChargeGroup instance... |
| charge_order |
|
| charge_profile |
|
| charge_profile_data |
|
| charge_profiles |
|
| charge_type |
A MajorChargeGroup can have 0-n ChargeType |
| charge_types |
A ChargeType can have 0-n ChargeComponent and a ChargeComponent can associate... |
| charge_version |
|
| charges |
All charges levied on this account |
| chc |
Control valves rate closing limit (Chc) |
| check_billing |
True if as a result of an inspection or otherwise, there is a reason to suspe... |
| check_out_type |
To indicate a check out type such as adjusted capacity or dispatch capacity |
| cheque |
Cheque used to tender payment |
| cheque_number |
Cheque reference number as printed on the cheque |
| child |
|
| child_charges |
All sub-components of this complex charge |
| child_cost_types |
|
| child_cugroups |
|
| cho |
Control valves rate opening limit (Cho) |
| cic |
Intercept valves rate closing limit (Cic) |
| cio |
Intercept valves rate opening limit (Cio) |
| circuit |
|
| circuit_count |
Number of circuits in duct bank |
| city_code |
City code |
| clamp |
Clamp on which this action is taken |
| clamp_action |
The clamp action that is performed on the clamp |
| class |
Peak, Off-peak, 24-hour |
|
|
| classification |
Pole class: 1, 2, 3, 4, 5, 6, 7, H1, H2, Other, Unknown |
| classification_condition |
Classification condition which this analog helps define |
| classification_type |
The classification mechanism used to group a set of objects together within a... |
| clearance |
Clearance associated with this clearance action |
| clearance_action |
Clearance action associated with this clearance |
| clearances |
All clearances applicable to this power system resource |
| cleared_mw |
The market transaction megawatt |
|
|
| cleared_price |
The price of the market transaction |
|
|
| cleared_value |
Cleared MW |
| clearing_price |
Clearing price of a CRR |
|
|
| clearing_resource_award |
|
| client_and_server |
If True the value indicates that the entity represented by the bilateral tabl... |
| client_id |
Identifiers of the person held by an organisation, such as a government agenc... |
| close_amps |
Close current (nominal) |
| close_voltage |
Close voltage in volts DC |
| closed |
|
| cnode_distribution_factor |
|
| code |
(if applicable) Utilities often make use of external reference systems, such ... |
| coefficient |
The polinomial coefficent of power 4 |
| cogen_hpsendout_rating |
The high pressure steam sendout |
| cogen_hpsteam_rating |
The high pressure steam rating |
| cogen_lpsendout_rating |
The low pressure steam sendout |
| cogen_lpsteam_rating |
The low pressure steam rating |
| cogeneration_plant |
A thermal generating unit may be a member of a cogeneration plant |
| cold_leg_fblag_tc |
Cold leg feedback lag time constant |
| cold_leg_fblead_tc |
Cold leg feedback lead time constant |
| cold_leg_fg |
Cold leg feedback gain 2 |
| cold_leg_lag_tc |
Cold leg lag time constant |
| cold_start_time |
Cold start time |
| column |
The matrix element's column number, in the range 1 to row |
| com_functions |
All functions this communication module performs |
| com_module |
Module performing this communication function |
| comb_cycle_plant_rating |
The combined cycle plant's active power output rating |
| combined_cycle_configuration |
|
| combined_cycle_configuration_member |
|
| combined_cycle_logical_configuration |
|
| combined_cycle_operating_mode |
Combined Cycle operating mode |
| combined_cycle_plant |
A thermal generating unit may be a member of a combined cycle plant |
| combined_cycle_unit_offer |
Will indicate if the unit is part of a CC offer or not |
|
|
| combustion_turbine |
A CAES air compressor is driven by combustion turbine |
| combustion_turbines |
A combustion turbine may have a heat recovery boiler for making steam |
| command |
Command text |
| commands |
The Commands using the set for translation |
| comment |
A user provided comment describing the changes in this version from the previ... |
| commercial_op_date |
Resource Commercial Operation Date |
| commericial_operation_date |
|
| commissioned_date |
|
| commitment_clearing |
|
| commitment_type |
the type of UC status (self commitment, ISO commitment, or SCUC commitment) |
|
|
| commitments |
|
| committed |
The date Power System Project is in committed stage |
| commodity |
Commodity being measured |
| commodity_currency |
The currency in which the Commodity is traded, using the standard conventions... |
| commodity_definition |
|
| commodity_price |
|
| commodity_type |
Energy product (commodity) type: |
|
|
| commodity_unit |
The unit of measure in which the Commodity is traded, using the standard conv... |
| commodity_unit_multiplier |
The unit multiplier, e |
| communication |
True if communication function is supported |
| communication_link |
Communication addressing for a Bilateral Table used by a ICCP data provider o... |
| communication_links |
RTUs may be attached to communication links |
| community_descriptor |
a name to denote the community - this could be a name or a code of some kind |
| compatible_units |
|
| competitive_path_constraint |
Non-competitive path constraint Flag"(Y/N) indicating whether the shadow pri... |
| complete_model_to_be_deleted |
|
| completed_date_time |
Date and time work task was completed |
| compliant_indicator |
Flag indicating whether or not the resource was in compliance with the instru... |
| component_erp_invoice_line_items |
|
| component_market_invoice_line_items |
|
| component_market_statement_line_item |
|
| component_type |
|
| composite_switch |
Composite switch to which this Switch belongs |
| composite_switch_type |
An alphanumeric code that can be used as a reference to extra information suc... |
| conclusion |
Conclusion drawn from test results |
| conclusion_confidence |
Description of confidence in conclusion |
| condenser_p |
Active power consumed when in condenser mode operation |
| condition |
Condition of seal |
| condition_after |
Condition of asset just following maintenance procedure |
| condition_before |
Description of the condition of the asset just prior to maintenance being per... |
| condition_factors |
|
| conducting_equipment |
The conducting equipment of the terminal |
| conducting_equipments |
Protection equipment may be used to protect specific conducting equipment |
| conductor_count |
Number of phase, neutral, and other wires retained |
| confidence |
A value set by the system, function, algorithm or person creating a predictio... |
| confidence_kind |
provides the confidence level that this ERT can be accomplished |
| config_id |
Configuration specified for this function |
| config_version |
The version of configuration of calculation logic in the settlement |
| configuration_event |
All configuration events created for this Power System resource |
| configuration_events |
All configuration events created for this asset |
| configuration_kind |
Configuration of joint |
| confirmation_required |
If true, the requesting entity (e |
| conform_load_group |
The ConformLoadGroup where the ConformLoadSchedule belongs |
| conform_load_schedules |
The ConformLoadSchedules in the ConformLoadGroup |
| congest_charge_max |
Maximum congestion charges in monetary units |
| congest_lmp |
Congestion component of Location Marginal Price (LMP) in monetary units per M... |
| congestion_area |
|
| congestion_lmp |
LMP component in USD (deprecated) |
|
|
| congestion_revenue_right |
|
| connect_disconnect |
If set to TRUE, the connect/disconnect function is supported |
| connect_disconnect_functions |
|
| connected |
The connected status is related to a bus-branch model and the topological nod... |
| connection_category |
A code used to specify the connection category, e |
| connection_kind |
Kind of connection |
| connection_state |
State of the usage point with respect to connection to the network |
| connection_status |
The current status for the Voltage Control Capacitor 1= Connected 0 = Disconn... |
| connectivity_node |
The connectivity node to which this terminal connects with zero impedance |
| connectivity_node_container |
The connectivity node container to which the topological node belongs |
| connectivity_nodes |
Connectivity nodes which belong to this connectivity node container |
| constant_coefficient |
Loss estimate constant coefficient |
|
|
| constrained_output_flag |
Constrained Output Generator (COG) Indicator (Yes/No), per Generating Resourc... |
| constraint_clearing |
|
| constraint_duration |
|
| constraint_ramp_type |
The condition that identifies whether a Generating Resource should be constra... |
| constraint_results |
|
| constraint_terms |
|
| constraint_type |
Type of constraint |
| construction |
The framing structure mounted on the pole |
| construction_kind |
Kind of construction for this transformer |
| consumer |
Subscriber of information from a remote peer |
| consumer_bilateral_exchange |
Agreement to information subscriber |
| consumption_tariff_intervals |
Tariff intervals to which this consumption-based charge has to be levied |
| consumption_tier |
In case of common flat-rate pricing for power, in which all purchases are at ... |
| contact_type |
Type of contact (e |
| contact_value |
Value of contact type (e |
| contained_in |
A TransmissionPath is contained in a TransmissionCorridor |
| contained_project |
Projects that are included in this parent project |
| container_erp_invoice_line_item |
|
| container_market_invoice_line_item |
|
| container_market_statement_line_item |
|
| containing_project |
The parent project of this project |
| contingency |
A contingency element belongs to one contingency |
| contingency_active |
Indication that the system is currently operating in a contingency mode |
| contingency_avail_flag |
Contingent operating reserve availiability (Yes/No) |
| contingency_constraint_limit |
|
| contingency_constraint_limits |
|
| contingency_element |
A contingency can have any number of contingency elements |
| contingency_equipment |
The contingency equipments in which this equipment participates |
| contingency_flag |
Contingent Operating Reserve Indicator (Yes/No) |
| contingent_operating_res_avail |
Global Contingent Operating Reserve Availability Indicator (Yes/No) |
| contingent_status |
The status for the associated equipment when in the contingency state |
| continuous_operating_voltage |
Maximum continuous power frequency voltage allowed on the surge arrester |
| contract_distribution_factor |
|
| contract_mw |
MW value of the contract |
|
|
| contract_number |
Existing transmission contract number |
|
|
| contract_price |
Financial value of the contract |
|
|
| contract_priority |
Priority for the contract |
| contract_right |
|
| contract_status |
Contract status |
|
|
| contract_type |
type of the contract |
| contractor_cost |
Total contractor costs associated with the work task |
| contractor_items |
|
| control |
The Control for the RemoteControl point |
| control_action |
The control action that is performed on the control |
| control_area |
The parent control area for the generating unit specifications |
| control_area_designation |
|
| control_area_generating_unit |
ControlArea specifications for this generating unit |
| control_area_solution_data |
|
| control_deadband |
Unit control error deadband |
| control_enabled |
Specifies the regulation status of the equipment |
| control_error_bias_p |
Active power error bias ratio |
| control_ic |
Integral constant |
| control_kind |
Kind of control (if any) |
| control_pc |
Proportional constant |
| control_peb |
Pressure error bias ratio |
| control_ped |
Pressure error deadband |
| control_pulse_high |
Pulse high limit which is the largest control pulse that the unit can respond... |
| control_pulse_low |
Pulse low limit which is the smallest control pulse that the unit can respond... |
| control_response_rate |
Unit response rate which specifies the active power change for a control puls... |
| control_tc |
Time constant |
| control_type |
Specifies the type of Control |
| controlled_by |
A ControlAreaCompany controls a ControlArea |
| controls |
The controller outputs used to actually govern a regulating device, e |
| converter_dcsides |
All converters' DC sides linked to this point of common coupling terminal |
| converter_fed_drive |
Indicates whether the machine is a converter fed drive |
| coolant_condition |
Temperature or pressure of coolant medium |
| coolant_temperature |
The machine's coolant temperature (e |
| coolant_type |
Method of cooling the machine |
| cooling_kind |
Kind of cooling system |
| cooling_offset |
Requested offset to apply to the normal cooling setpoint at the time of the s... |
| cooling_setpoint |
Requested cooling set point |
| coordinate_system |
Coordinate system used to describe position points of this location |
| core_admittance |
Core admittance of this transformer end, representing magnetising current and... |
| core_burden |
Power burden of the CT core |
| core_coils_weight |
Weight of core and coils in transformer |
| core_count |
Number of cores |
| core_htlag_tc |
Core heat transfer lag time constant |
| core_kind |
Core kind of this transformer product |
| core_neutronics_eff_tc |
Core neutronics effective time constant |
| core_neutronics_ht |
Core neutronics and heat transfer |
| core_radius |
(if there is a different core material) Radius of the central core |
| core_strand_count |
(if used) Number of strands in the steel core |
| corporate_code |
A codified representation of the business case (i |
| corporate_standard_kind |
Kind of corporate standard for this asset model |
| cost |
The total amount charged |
| cost_description |
Description of the cost |
| cost_estimate |
Estimated cost (not price) of design |
| cost_lmp |
Cost component of Locational Marginal Pricing (LMP) in monetary units per MW |
| cost_per_unit |
The cost per unit for this misc |
| cost_recovery |
Charge for Emission Costs, Start Up Costs, or Minimum Load Costs |
| cost_type |
Type of cost to which this Material Item belongs |
| cost_types |
|
| counter_trade_quantity |
MW quantity submitted by counter SC for the same trade |
|
|
| country |
Name of the country |
| country_code |
Country code |
| coverage_kind |
Code representing the coverage of the weather condition |
| cpp |
Critical peak period (CPP) bucket the reading value is attributed to |
| cpsmn |
Minimum value of pressure regulator output (Cpsmn) |
| cpsmx |
Maximum value of pressure regulator output (Cpsmx) |
| crafts |
|
| created |
|
| created_date_time |
Date and time that this document was created |
| created_iso |
A Yes indicates that this bid was created by the ISO |
| credit_flag |
Flag to indicate creditworthiness (Y, N) |
| credit_start_effective_date |
Date that the scheduling coordinator becomes creditworthy |
| crew |
The crew that is assigned to this locaton |
| crew_eta |
Estimated time of arrival, so that customer or police/fire department can be ... |
| crew_members |
All members of this crew |
| crew_type |
Type of this crew |
| crews |
|
| critical |
True if asset is considered critical for some reason (for example, a pole wit... |
| critical_count |
Number of critical service (delivery) points affected by an outage |
| criticality_level |
Level of criticality for the action of this control |
| crmn |
Minimum value of regulator set-point (Crmn) |
| crmx |
Maximum value of regulator set-point (Crmx) |
| cross_compound_turbine_governor_dyanmics |
The cross-compound turbine governor with which this high-pressure synchronous... |
| cross_compound_turbine_governor_dynamics |
The cross-compound turbine governor with which this low-pressure synchronous ... |
| cross_time |
Time to cross the forbidden region in minutes |
| crossing_cost |
Cost associated with crossing the forbidden region |
|
|
| crossover_tc |
Crossover time constant |
| crrmarket |
|
| crrorg_role |
|
| crrsegment |
|
| crs_urn |
A Uniform Resource Name (URN) for the coordinate reference system (crs) used ... |
| cscdynamics |
Current source converter dynamics model used to describe dynamic behaviour of... |
| csconverter |
Current source converter to which current source converter dynamics model app... |
| csctype |
|
| cscuser_defined |
Proprietary user-defined model with which this parameter is associated |
| cswitch |
Power source switch (Cswitch) |
| ct_class |
CT classification; i |
| ct_rating |
Built-in current transformer primary rating |
| ct_ratio |
Built-in current transducer ratio |
| cttemp_active_power_curve |
A combustion turbine may have an active power versus ambient temperature rela... |
| ctw |
Selector for second washout enabling (CTW2) |
| cu_account |
A code that helps direct accounting (capital, expense, or accounting treatmen... |
| cu_action |
A code that instructs the crew what action to perform |
| cu_quantity |
The quantity of the CU being assigned to this location |
| cu_usage |
As the same CU can be used for different purposes and accounting purposes, us... |
| cuallowable_action |
|
| cucontractor_items |
|
| cugroup |
|
| cugroups |
|
| culabor_code |
|
| culabor_items |
|
| cum_energy |
Cumulative energy production over trading period |
| cum_status_changes |
Cumulative number of status changes of the resource |
| cumaterial_items |
|
| currency |
Currency of this quantity |
| current |
Current total amount now due: current = principle + arrears + interest + char... |
| current_amount |
Current settlement amount |
| current_balance |
The current operating balance of this account |
| current_emergency_si |
|
| current_isoamount |
Current ISO settlement amount |
| current_isoquantity |
Current ISO settlement quantity |
| current_limit |
Current limit number 3 for inverse time pickup |
| current_net_tie_mw |
Current control area net tie MW (the sum of the tie line flows, i |
| current_price |
Current settlement price |
| current_quantity |
Current settlement quantity, subject to the UOM |
| current_scheduled_interchange |
|
| current_state |
|
| current_time_date |
Current time as determined by a PAN device |
| curtail_time_max |
Maximum curtailment time in number of trading intervals |
|
|
| curtail_time_min |
Minimum curtailment time in number of trading intervals |
|
|
| curtailment_profiles |
An EnergyTransaction may be curtailed by any of the participating entities |
| curve |
The curve of this curve data point |
| curve_datas |
The point data values that define this curve |
| curve_style |
The style or shape of the curve |
| curve_style_kind |
Used to specify whether the values over an interval are constant (constantYVa... |
| curve_type |
The coded representation of the type of curve being described |
| cust_child_of |
A ControlAreaOperator or CustomerConsumer may ring their perimeter with mete... |
| customer |
The customer represented by the person |
| customer_account |
All customer accounts for the meter read schedule |
| customer_accounts |
All accounts of this customer |
| customer_agreement |
All customer agreements for the meter read schedule |
| customer_agreements |
All agreements of this customer |
| customer_billing_infos |
|
| customer_count |
Number of individual customers represented by this demand |
| customer_data |
|
| customer_notification_type |
Notifications for move-in, move-out, delinquencies, planned outage, demand re... |
| customer_notifications |
All notifications for a customer related to the status change of this inciden... |
| customer_voltage_limit |
Voltage limit on customer side of RCD switch above which the connect should n... |
| customers |
All the customers for which this work is performed |
| customers_restored |
number of customers that have been restored in the area |
| cut |
Cuts applied to the line segment |
| cut_action |
Action taken with this cut |
| cut_level |
Second level (amount) of load to cut as a percentage of total zone load |
| cuwork_equipment_asset |
|
| cuwork_equipment_items |
|
| cv_number |
The card verification number |
| cycle_count |
Number of cycles for a temporary shift |
| d |
Turbine damping factor (D) |
| daily_ceiling_usage |
Absolute maximum valid non-demand usage quantity used in validating a custome... |
| daily_estimated_usage |
Used in place of actual computed estimated average when history of usage is n... |
| daily_floor_usage |
Absolute minimum valid non-demand usage quantity used in validating a custome... |
| damping |
Damping torque coefficient (D) (>= 0) |
| data_entry_time_stamp |
Time the data entry was performed |
|
|
| data_set |
|
| dataset |
The data belonging to the alternate model |
| dataset_arg |
The role of a dataset in the context of an operation |
| date |
Form is YYYY-MM-DD for example for January 5, 2009 it is 2009-01-05 |
| date_and_or_time |
|
| date_time |
Date and time the asset was last tested using the 'type' of test and yielding... |
| date_time_of_report |
Date and time the trouble has been reported |
| day_over_load_rating |
Overload rating for 24 hours |
| day_type |
DayType for the Schedule |
| db |
Speed governor deadband in PU speed (db) |
| dbf |
Frequency deadband (DBF) |
| dcconducting_equipment |
The operating condition to the Conducting Equipment is changed when protectiv... |
| dcconverter_unit |
The DC converter unit belonging of the substation |
| dcequipment_container |
The DC container for the DC nodes |
| dcline_segments |
All line segments described by this set of per-length parameters |
| dclines |
The DC lines in this sub-geographical region |
| dcnode |
The DC connectivity node to which this DC base terminal connects with zero im... |
| dcnodes |
The DC nodes contained in the DC equipment container |
| dcterminals |
DC base terminals interconnected with zero impedance at a this DC connectivit... |
| dctopological_island |
A DC topological node belongs to a DC topological island |
| dctopological_node |
The topological nodes which belong to this connectivity node container |
| dctopological_nodes |
The DC topological nodes in a DC topological island |
| dcvoltage_control |
|
| de_energized_usage_point |
all deenergized useage points associated with the outage |
| deadband |
The smallest change in value to be reported |
| deadline |
The deadline for compliance |
| deb_adder_flag |
Default energy bid adder flag |
|
|
| default_bid |
|
| default_bid_curve |
|
| default_capacity |
default capacity |
| default_constraint_limit |
|
| default_integration_method |
The default method by which interchange schedules are to be integrated to obt... |
| default_price |
Bid Default Price($/MWH) |
|
|
| delay |
|
| delete_status |
|
| delivery_date |
|
| delivery_pnode |
|
| delivery_point |
A transmission path has a "point-of-delivery" service point |
| delivery_point_p |
Delivery point active power |
| delivery_transaction_bids |
|
| delta |
Angle between VsConverter |
| demand_bid_mw |
The Demand Bid Megawatt for the area case |
| demand_response |
True if demand response function is supported |
| demand_response_actual_event |
|
| demand_response_programs |
All demand response programs the customer is enrolled in through this custome... |
| demand_transaction |
Set true if this is a demand transaction |
| demographic_kind |
Demographics around the site |
| denominator |
Denominator |
| denpendecy_depending_stage |
|
| density |
Particulate density of the ash cloud during the time interval |
| depend_on_trade_name |
The Depend On IST Name points to the unique IST Name in the chain of physical... |
| dependency_dependent_on_stage |
|
| dependency_type |
|
| dependent_on_stage |
|
| depending_stage |
|
| depends_on |
|
| deployment_date |
Dates of asset deployment |
| deployment_state |
Current deployment state of asset |
| deposit |
Amount of price on deposit |
| der_function |
The DER functions that are applied to the DER Group |
| dercurve_data |
Specifies the time dependent curve for a DER monitorable parameter |
| derfunction |
Functions supported by the DER Group |
| dergroup_dispatch |
An individual dispatch for a DER Group |
| dergroup_forecast |
An individual forecast for a DER Group |
| dermonitorable_parameter |
The DER monitorable parameters associated with a DER Group |
| derparameter |
Defines the specific engineering value being forecasted or dispatched |
| description |
The description is a free human readable text describing or naming the object |
| design |
|
| design_location |
|
| design_location_cus |
|
| design_locations |
|
| design_locations_cus |
|
| designs |
|
| desired_mw |
Desired output of unit |
|
|
| desired_voltage |
The desired voltage for the Voltage Control Capacitor |
|
|
| detail_quantity |
Additional information related to the associated quantity |
| detection_limit |
Detection limit of related analog value if different from detection limit of ... |
| dfimax |
Maximum rate of change of frequency (dFmax) |
| dga |
Dissolved Gas Analysis |
| dhp |
HP damping factor (Dhp) |
| diagram |
A diagram object is part of a diagram |
| diagram_elements |
A diagram is made up of multiple diagram objects |
| diagram_object |
The diagram object with which the points are associated |
| diagram_object_glue_point |
The 'glue' point to which this point is associated |
| diagram_object_points |
A diagram object can have 0 or more points to reflect its layout position, ro... |
| diagram_object_style |
A diagram object has a style associated that provides a reference for the sty... |
| diagram_objects |
The diagram objects that are associated with the domain object |
| diagram_style |
A Diagram may have a DiagramStyle |
| dial_out |
(if applicable) Dial out code, for instance to call outside an enterprise |
| diameter |
Diameter of the pole |
| diameter_over_core |
Diameter over the core, including any semi-con screen; should be the insulati... |
| diameter_over_insulation |
Diameter over the insulating layer, excluding outer screen |
| diameter_over_jacket |
Diameter over the outermost jacketing layer |
| diameter_over_neutral |
Diameter over the concentric neutral strands |
| diameter_over_screen |
Diameter over the outer screen; should be the shield's inside diameter |
| dicn |
Value to allow the integral controller to advance beyond the gate limits (... |
| dielectric_strength |
The maximum rms voltage that may be applied across an open contact without br... |
| dimensions_infos |
|
| dipmax |
Maximum active current ramp rate (dipmax) |
| diqmax |
Maximum reactive current ramp rate (diqmax) |
| diqmin |
Minimum reactive current ramp rate (diqmin) |
| direction |
(if applicable) Direction that allows field crews to quickly find a given ass... |
| direction_type |
Import or export |
| disabled |
True if this schedule is deactivated (disabled) |
| discharge_travel_delay |
Water travel delay from tailbay to next downstream hydro power station |
| disconnection_method |
Is an indication of how the usage point is physically connected or disconnect... |
| discontinuous_excitation_control_dynamics |
Discontinuous excitation control model associated with this excitation system... |
| discontinuous_excitation_control_user_defined |
Proprietary user-defined model with which this parameter is associated |
| discount |
Discount from standard price |
| discrete |
The regulation is performed in a discrete mode |
| discrete_value |
The integer value used for the command or the accumulator reset |
| discrete_values |
The values connected to this measurement |
| discretes |
The Measurements using the set for translation |
| disp_window_high_limt |
|
| disp_window_low_limt |
|
| dispatch_ct_mw |
Dispatchable MW for Combustion units |
| dispatch_hydro_mw |
Dispatchable MW for Hydro units |
| dispatch_inst_reply |
|
| dispatch_mode |
|
| dispatch_rate |
Dispatch rate in MW/minutes |
| dispatch_schedule |
The schedule used for dispatching or forecasting the values of DER monitorabl... |
| dispatch_status |
The status of one or more crews dispatched to perform field work at one or mo... |
| dispatch_steam_mw |
Dispatchable MW for Steam units |
| dispatchable |
Dispatchable: indicates whether the resource is dispatchable |
| dispatcher_added_mw |
The tier2 mw added by dispatcher action |
|
|
| displacement |
|
| distance |
Distance to the end of coupled region from the second line's terminal with se... |
| distributed_resource_type |
The type of resource |
| distribution_factor |
|
| distribution_factor_set |
|
| diverse_reference |
Formal reference for use with diverse payment (traffic fine for example) |
| divisible |
An indication whether or not each element of the bid may be partially accepte... |
| dl |
Limiter (Dl) |
| dlp |
LP damping factor (Dlp) |
| dm |
Speed sensitivity coefficient (Dm) |
| doc_status |
Status of this document |
| document |
The document having associated activity records |
| documents |
All documents of this this author |
| domain |
High-level nature of the event |
| donor_reference |
Reference to the entity that is the source of 'amount' (for example: customer... |
| dop_instruction |
|
| dot |
Dispatch operating target value |
| dot_instruction |
|
| down_time_max |
Maximum down time |
| dpmax |
Maximum wind turbine power ramp rate (dpmax) |
| dpmaxp_a |
Maximum wind turbine power ramp rate (dpmaxp4A) |
| dpmaxp_b |
Maximum wind turbine power ramp rate (dpmaxp4B) |
| dpmin |
Rate limit for decreasing power (dpmin) (< WindPi... |
| dpnf |
Controller follow up deadband (Dpnf) |
| dpomega |
Partial derivative of aerodynamic power with respect to changes in WTR speed ... |
| dprefmax |
Maximum ramp rate of pWTref request from the plant c... |
| dprefmin |
Minimum (negative) ramp rate of pWTref request from ... |
| dptheta |
Partial derivative of aerodynamic power with respect to changes in pitch angl... |
| dpv |
Value to allow the pilot valve controller to advance beyond the gate limits (... |
| dpwprefmax |
Maximum positive ramp rate for wind plant power reference (dpW... |
| dpwprefmin |
Maximum negative ramp rate for wind plant power reference (dpW... |
| dr_program_level |
Level of a demand response program request, where 0=emergency |
| dr_program_mandatory |
Whether a demand response program request is mandatory |
| drawing_number |
Drawing number for asset model |
| drawing_order |
The drawing order of this element |
| droop |
Droop constant |
| droop_compensation |
Compensation constant |
| drop_height |
The height water drops from the reservoir mid-point to the turbine |
| drop_ramp_rate |
Maximum rate that load can be reduced (MW/minute) |
|
|
| drum_boiler_rating |
Rating of drum boiler in steam units |
| dst |
True if daylight savings time (DST) is in effect |
| dst_observed |
Whether this station is currently reporting using daylight saving time |
| dt |
Turbine damping coefficient (Dt) |
| dtc |
Exhaust temperature variation due to fuel flow increasing from 0 to 1 PU (... |
| dtf |
Time step frequency calculation (deltatf) (>= 0) |
| dthetamax |
Maximum pitch positive ramp rate (dthetamax) (> W... |
| dthetamaxuvrt |
Limitation of torque rise rate during UVRT (dthetamaxUVRT</sub... |
| dthetamin |
Maximum pitch negative ramp rate (dthetamin) ... |
| dtp |
Time step active power calculation (deltatp) (>= 0) |
| dturb |
Turbine damping factor (Dturb) |
| duct_bank |
|
| due |
Current amounts now due for payment on this account |
| due_date |
Calculated date upon which a customer billing amount is due, used in the invo... |
| due_date_time |
Date and time by which payment for bill is expected from client |
| duration |
The duration the compare condition need to be present before given a true |
| duration_indefinite |
True if 'duration' is indefinite |
| duty_cycle |
Maximum "on" state duty cycle as a percentage of time |
| dxrefmax |
Maximum positive ramp rate for wind turbine reactive power/voltage reference ... |
| dxrefmin |
Maximum negative ramp rate for wind turbine reactive power/voltage reference ... |
| dyn_sched_sign_rev |
Dynamic schedule sign reversal required (true/false) |
|
|
| dyn_sched_status |
The "active" or "inactive" status of the dynamic schedule |
|
|
| dynamic_schedule |
|
| dynamically_scheduled_load_resource |
Flag to indicate that a Load Resource is part of a DSR Load |
| dynamically_scheduled_qualification |
Qualification status (used for DSR qualification) |
| e |
Exponent (e) |
| earliest_date_time_to_call |
Earliest date time to call the customer |
| earliest_reported_time |
This is the reported time of the first outage report |
| earthing |
Indicates whether or not the generator is earthed |
| earthing_star_point_r |
Generator star point earthing resistance (Re) |
| earthing_star_point_x |
Generator star point earthing reactance (Xe) |
| ecaflag |
Indication that this resource is associated with an Embedded Control area |
| economic_dispatch_limit |
Limit for Economic Dispatch priority 6 energy flow on the specified flowgate ... |
| economic_max |
Unit max output for dispatch; bid in economic maximum |
|
|
| economic_max_override |
Economic Max Limit override for unit, this value is null, if it is not, this ... |
| economic_min |
Unit min output for dispatch; bid in economic minimum |
|
|
| ecr |
Combustion reaction time delay (Ecr) (>= 0) |
| editor |
Editor of this document |
| efd |
Exciter voltage at which exciter saturation is defined (EFD2</... |
| efd_base_ratio |
Ratio (exciter voltage/generator voltage) of Efd bases of exciter and ... |
| efdbas |
Gain (Efdbas) |
| efddes |
Desired field voltage (EFDDES) |
| efdlim |
(Efdlim) |
| efdmax |
Maximum field voltage (EFDMax) (>= 0) |
| efdmin |
Minimum open circuit exciter voltage (Efdmin) (< ExcBBC |
| efdn |
Value of Efd at which feedback gain changes (EFDN... |
| efdrated |
Rated field voltage (EFDRATED) |
| eff_regulation_down_limit |
Effective Regulation Down Limit (MW) |
|
|
| eff_regulation_up_limit |
Effective Regulation Up Limit |
|
|
| effect |
Effect of problem |
| effective_date |
Date/Time when record becomes effective |
|
|
| effective_date_time |
The date/time the change set is included in the model |
| effective_end_time |
|
| effective_period |
Period between the assignment becoming effective and its expiration |
| effective_start_time |
|
| efficiency |
The efficiency of the unit in converting mechanical energy, from the prime mo... |
| efmax |
Maximum open circuit excitation voltage (Efmax) (> ExcELIN1 |
| efmin |
Minimum open circuit excitation voltage (Efmin) (< ExcELIN1 |
| ehv_loss_mw |
EHV MW losses in the company |
|
|
| electric_metering |
True if electric metering function is supported |
| electronic_address |
Electronic address |
| electronic_address_alternate |
Alternate Electronic address |
| electronic_address_primary |
Primary Electronic address |
| eligibility_status |
Indicates whether a resource is eligible for PIRP program for a given hour |
|
|
| email |
Alternate email address |
| emax |
Maximum control error (Emax) (see parameter detail 4) |
| embedded_control_area |
Used in conjunction with the InternalCA flag |
| emergency |
Repair work is emergency |
| emergency_high_volt_limit |
Emergency high voltage limit |
| emergency_low_volt_limit |
Emergency low voltage limit |
| emergency_s |
Apparent power that the winding can carry under emergency conditions (also ca... |
| emergency_schedule_mw |
Net tie MW |
| emergency_schedule_ramp_time |
Ramp time, the ramping time for a schedule |
| emergency_schedule_start_time |
Net tie time, the start time for a schedule |
| emin |
Field voltage control signal lower limit on AVR base (Emin) (< ExcH... |
| emission_content |
The emission content per quantity of fuel burned |
| emission_curves |
A thermal generating unit may have one or more emission curves |
| emission_type |
The type of emission, which also gives the production rate measurement unit |
| emission_value_source |
The source of the emission value |
| emmission_accounts |
A thermal generating unit may have one or more emission allowance accounts |
| enabled |
The status of the class set by operation or by signal |
| end |
End time of this interval |
| end_aflow |
|
| end_bay |
|
| end_bflow |
|
| end_date |
(if tariff became inactive) Date tariff was terminated |
| end_date_time |
segment end date time |
|
|
| end_device |
All end devices for the meter read schedule |
| end_device_action |
End device action issued by this end device control |
| end_device_control |
End device control issuing this end device action |
| end_device_control_type |
Type of this end device control |
| end_device_controls |
All end device controls sending commands to this usage point |
| end_device_event |
End device owning this detail |
| end_device_event_details |
All details of this end device event |
| end_device_event_type |
Type of this end device event |
| end_device_events |
All end device events reported for this usage point |
| end_device_function |
End device function metering quantities displayed by this register |
| end_device_functions |
All end device functions this end device performs |
| end_device_group |
All end device groups for the meter read schedule |
| end_device_groups |
All end device groups referring to this end device |
| end_device_info |
End device data |
| end_devices |
All end devices of this customer |
| end_number |
Number for this transformer end, corresponding to the end's order in the powe... |
| end_terminal |
|
| end_time |
The time for the last time point |
| energised_end |
Transformer end that voltage is applied to in this short-circuit test |
| energised_end_no_load_tests |
All no-load test measurements in which this transformer end was energised |
| energised_end_open_circuit_tests |
All open-circuit test measurements in which this transformer end was excited |
| energised_end_short_circuit_tests |
All short-circuit test measurements in which this transformer end was energis... |
| energised_end_step |
Tap step number for the energised end of the test pair |
| energised_end_voltage |
Voltage applied to the winding (end) during test |
| energized_usage_point |
All energized usage points associated with this outage |
| energy_area |
The energy area that is forecast from this control area specification |
| energy_component |
|
| energy_connection |
|
| energy_consumer |
The energy consumer to which this phase belongs |
| energy_consumer_action |
The energy consumer action that is performed on the energy consumer |
| energy_consumer_phase |
The individual phase models for this energy consumer |
| energy_consumers |
Energy consumer is assigned to the power cut zone |
| energy_conversion_capability |
Energy conversion capability for generating |
| energy_cost |
Total Energy Cost ($) over the time horizon |
|
|
| energy_down_ramp_rate |
Response rate in MW per minute for ramping energy down |
| energy_group |
|
| energy_level |
Energy level for the profile, in MWH |
| energy_limit |
Limit of energy before disconnect |
| energy_market |
|
| energy_markets |
|
| energy_max_day |
Maximum amount of energy per day which can be produced during the trading per... |
| energy_min |
Transaction minimum active power if dispatchable |
| energy_min_day |
Minimum amount of energy per day which has to be produced during the trading ... |
| energy_price |
market energy price |
|
|
| energy_price_curve |
|
| energy_price_curves |
|
| energy_price_index |
|
| energy_price_index_type |
EPI type such as wholesale or retail |
| energy_product |
The "Source" for an EnergyTransaction is an EnergyProduct which is injected i... |
| energy_product_type |
Under each major product type, the commodity type can be applied to further s... |
| energy_profiles |
An EnergyTransaction shall have at least one EnergyProfile |
| energy_scheduling_type |
Energy Scheduling Type of an Energy Source |
| energy_source |
The energy sourceto which the phase belongs |
| energy_source_action |
Action taken with this energy source |
| energy_source_phase |
The individual phase information of the energy source |
| energy_storage_capacity |
The rated energy storage capacity |
| energy_storage_rating |
The reservoir's energy storage rating in energy for given head conditions |
| energy_transaction |
An EnergyTransaction may have a LossProfile |
| energy_transactions |
|
| energy_type |
Energy product type |
| energy_type_code |
|
| energy_type_reference |
|
| energy_unit |
Unit of service |
| energy_up_ramp_rate |
Response rate in MW per minute for ramping energy up |
| energy_usage_start_date_time |
Start date and time to accumulate energy for energy usage limiting |
| energy_usage_warning |
Warning energy limit, used to trigger event code that energy usage is nearing... |
| enforced |
True if limit is enforced |
| enrollment_group |
Provides a mechanism to direct load control actions to groups of PAN devices |
| entitlement |
the entitlement |
|
|
| environmental_alert |
Environmental alert applying to location of this type |
| environmental_analog |
Environmental analog measurement provided by this monitoring station |
| environmental_data_authority |
Authority defining this environmental phenomenon |
| environmental_data_provider |
Environmental data provider supplying this environmental information |
| environmental_discrete |
Environmental discrete (integer) associated with this observation or forecast |
| environmental_event |
Environmental event to which this forecast or observation relates |
| environmental_information |
Observation or forecast with which this environmental analog measurement is a... |
| environmental_location_kind |
Kind of environmental location which this location is |
| environmental_monitoring_station |
Monitoring station located at this location |
| environmental_phenomenon |
|
| environmental_string_measurement |
Environmental string measurement associated with this forecast or observation |
| ep |
Third term voltage exponent for active power (Ep3) |
| epfd |
Active load-frequency dependence index (dynamic) (Epfd) |
| epfs |
Active load-frequency dependence index (static) (Epfs) |
| eps |
Intentional db hysteresis (eps) |
| epvd |
Active load-voltage dependence index (dynamic) (Epvd) |
| epvs |
Active load-voltage dependence index (static) (Epvs) |
| eq |
Third term voltage exponent for reactive power (Eq3) |
| eqfd |
Reactive load-frequency dependence index (dynamic) (Eqfd) |
| eqfs |
Reactive load-frequency dependence index (static) (Eqfs) |
| eqiupment_limit_series_component |
Equipment limit series calculation component to which this equipment contribu... |
| equation |
|
| equip_code |
The equipment type code |
| equipment |
The equipment to which the limit set applies |
| equipment_container |
Container of this equipment |
| equipment_faults |
The equipment faults at this terminal |
| equipment_limit_series_component |
Equipment linkages that participates in the limit calculation |
| equipment_to_be_isolated |
free-form list of the equipment to be isolated by the switching |
| equipment_unavailability_schedule |
|
| equipments |
Contained equipment |
| equivalent_equipments |
The associated reduced equivalents |
| equivalent_injection |
The equivalent injection using this reactive capability curve |
| equivalent_network |
The equivalent where the reduced model belongs |
| eqvd |
Reactive load-voltage dependence index (dynamic) (Eqvd) |
| eqvs |
Reactive load-voltage dependence index (static) (Eqvs) |
| erp_bom |
|
| erp_bom_item_datas |
|
| erp_boms |
|
| erp_competency |
|
| erp_inventory |
|
| erp_inventory_issues |
|
| erp_invoice |
|
| erp_invoice_line_item |
Some utilities provide quotes to customer for services, where the customer ac... |
| erp_invoice_line_items |
|
| erp_invoicees |
|
| erp_issue_inventories |
|
| erp_item_master |
|
| erp_jounal_entry |
|
| erp_journal |
|
| erp_journal_entries |
|
| erp_led_bud_line_item |
|
| erp_led_bud_line_items |
|
| erp_ledger |
|
| erp_ledger_budget |
|
| erp_ledger_entries |
|
| erp_ledger_entry |
|
| erp_line_items |
|
| erp_organisation_roles |
|
| erp_payable |
|
| erp_payable_line_item |
|
| erp_payable_line_items |
|
| erp_payables |
|
| erp_payments |
|
| erp_person |
|
| erp_person_roles |
|
| erp_personnel |
|
| erp_persons |
|
| erp_poline_item |
|
| erp_poline_items |
|
| erp_project_accounting |
|
| erp_purchase_order |
|
| erp_quote |
|
| erp_quote_line_item |
|
| erp_quote_line_items |
|
| erp_rec_del_line_item |
|
| erp_rec_delivery_items |
|
| erp_rec_delv_line_item |
|
| erp_rec_delv_line_items |
|
| erp_rec_line_item |
|
| erp_rec_line_items |
|
| erp_receivable |
|
| erp_receive_delivery |
|
| erp_req_line_item |
|
| erp_req_line_items |
|
| erp_requisition |
|
| erp_site_level_datas |
|
| erp_time_entries |
|
| erp_time_sheet |
|
| err_message |
error message |
|
|
| err_priority |
Priority number for the error message |
|
|
| error_ellipse_confidence |
Likelihood that strike fell within errorEllipse |
| error_ellipse_major_semi_axis |
Length of major semi-axis (longest radius) of the error ellipse |
| error_ellipse_minor_semi_axis |
Length of minor semi-axis (shortest radius) of the error ellipse |
| error_ellipse_orientation |
The orientation of the major semi- axis in degrees from True North |
| ert |
estimated time the outage will be restored |
| ert_source |
defines the source that provided the ERT value |
| esc |
Speed change reference (ESC) |
| est_cost |
Estimated total cost for perfoming CU |
| est_unit_cost |
The estimated unit cost of this type of material, either for a unit cost or c... |
| estimated_completion_time |
Time and Date when the work task will be completed |
| estimated_load |
Estimated load |
| estimated_period |
Estimated outage period for a planned outage |
| estimated_restoration_time |
The estimated time that the power will be restored after an outage |
| estimated_unit_cost |
Estimated unit cost (or cost per unit length) of this type of asset |
| estimated_window |
Estimated date and time for activity execution (with earliest possibility of ... |
| estimator_replaced |
Value has been replaced by State Estimator |
| etamax |
Maximum efficiency (EtaMax) |
| etd |
Turbine and exhaust delay (Etd) (>= 0) |
| evaluation_description |
Description of the performance evaluation, e |
| evaluation_value |
The value of the performance |
| event_comments |
Free format comments for the event, for any purpose needed |
| event_count |
Running cumulative count of connect or disconnect events, for the lifetime of... |
| event_end_time |
End time of the event |
| event_or_action |
The most specific part of this event type |
| event_start_time |
Start time of the event |
| event_status |
Event status, e |
| event_type |
Actual event type |
| ex_post_cleared_price |
|
| ex_post_loss |
|
| ex_post_loss_results |
|
| ex_post_market_region |
|
| ex_post_market_region_results |
|
| ex_post_pricing |
|
| ex_post_resource |
|
| ex_post_resource_results |
|
| ex_post_results |
|
| exceeded_limit |
true if limit exceeded |
|
|
| exception |
|
| excitation_system_dynamics |
Excitation system model associated with this synchronous machine model |
| excitation_system_user_defined |
Proprietary user-defined model with which this parameter is associated |
| exciting_current |
Exciting current measured from a positive-sequence or single-phase excitation... |
| exciting_current_zero |
Exciting current measured from a zero-sequence open-circuit excitation test |
| exclim |
(exclim) |
| exclusive_bids_identification |
Unique identification associated with all linked tenders |
| executed_date_time |
Actual date and time of this switching step |
| execution_type |
The execution type; Day Ahead, Intra Day, Real Time Pre-Dispatch, Real Time D... |
| exlon |
Overexcitation or under excitation flag (EXLON) |
|
|
| expected_energy |
Expected energy |
| expected_energy_values |
|
| expected_mwh |
|
| expiration_date |
This is the terminate date of the application for the organization |
|
|
| expiry_date |
The date when this card expires |
| explosives_used |
True if explosives have been or are planned to be used |
| exponent_model |
Indicates the exponential voltage dependency model is to be used |
| export_energy_transactions |
Energy is transferred between interchange areas |
| export_mwrating |
Export MW rating |
|
|
| export_sub_control_area |
Energy is transferred between interchange areas |
| ext_name |
the name of the extension |
| ext_type |
The type of the extension |
| ext_value |
the value of the extension |
| extension |
(if applicable) Extension for this telephone number |
| extensions_item |
a compound type that defines the extension name, type and value |
| external_record_reference |
Reference allocated by the governing organisation (such as municipality) to t... |
| external_ref_id |
External reference identifier (e |
| extreme_long_start |
Some long-start up time units may need to receive start up instruction before... |
| f_scale |
Fujita scale (referred to as EF-scale starting in 2007) for the tornado |
| facility_kind |
Kind of facility (like substation or pole or building or plant or service cen... |
| factor |
Used to calculate load "participation" of a connectivity node in an host cont... |
| factor_description |
Description (name) of the property (factor) |
| factor_value |
Value of the property (factor) |
| failure |
This identifier indicates that a supervision function has detected an interna... |
| failure_classification |
Classification of failure |
| failure_date_time |
Time and date of asset failure |
| failure_isolation_method |
How the asset failure was isolated from the system |
| failure_mode |
What asset failed to be able to do |
| fault |
All faults at this location |
| fault_cause_type |
Fault cause type whose change resulted in this configuration event |
| fault_cause_types |
All types of fault cause |
| fault_locating_method |
The method used for locating the faulted part of the asset |
| faults |
All faults on this equipment |
| faulty_equipment |
Equipment carrying this fault |
| fb |
Frequency bias gain (Fb) |
| fbf |
Frequency bias flag (Fbf) |
| fcut |
Frequency deadband (fcut) (>= 0) |
| feed_water_ig |
Feedwater integral gain ratio |
| feed_water_pg |
Feedwater proportional gain ratio |
| feed_water_tc |
Feedwater time constant ratio |
| feedback_factor |
Feedback factor |
| feedback_signal |
Feedback signal type flag (Flag) |
| fhp |
Fraction of HP power ahead of reheater (Fhp) |
| fidle |
Fuel flow at zero power output (Fidle) |
| field_dispatch_history |
The dispatch history associated with the crew |
| field_dispatch_step |
The field dispatch step that has the field dispatch history |
| fill_kind |
Material used to fill the joint |
| final_cause |
Cause of problem determined during diagnosis |
| final_code |
Code for diagnosed probem type |
| final_origin |
Origin of problem determined during diagnosis |
| final_remark |
Remarks pertaining to findings during problem diagnosis |
| financial_info |
Financial information related to this asset |
| financial_location |
Indicator if the location associated with this contract is financial (e |
| financial_rights_dam |
Flag to indicate this contract provides financial rights in the DA Market |
| financial_rights_rtm |
Flag to indicate this contract provides financial rights in the RT Market |
| financial_value |
Value of asset as of 'valueDateTime' |
| firm_interchange_flag |
Firm interchange flag indicates whether or not this energy transaction can be... |
| firm_network_limit |
Limit for firm flow on the specified flowgate for the specified time period |
| firmware_id |
Firmware version |
| first_name |
Person's first name |
| first_responder_status |
Indicates whether the first responder such as police, fire department etc |
| first_terminal |
The starting terminal for the calculation of distances along the first branch... |
| five_min_auxillary_data |
|
| fixed_amount |
The fixed amount that has to be collected from each vending transaction towar... |
| fixed_contact |
Fixed contact of interrupter to which this bushing is attached |
| fixed_maint_cost |
Fixed maintenance cost |
| fixed_portion |
The fixed portion of this charge element |
| fl |
Flowgate 5 (Fl5) |
| flexible_offer_flag |
Flexible offer flag (Y/N) |
| flim |
Frequency threshold 9 (Flim9) |
| flimf |
Limit type flag (Flimf) |
| float_parameter_value |
Floating point parameter value |
| floor |
Floor of location |
| floor_identification |
The identification by name or number, expressed as text, of the floor in the ... |
| flow_direction |
Flow direction for a reading where the direction of flow of the commodity is ... |
| flow_direction_flag |
Specifies the direction of energy flow in the flowgate |
| flowgate |
|
| flowgate_partner |
|
| flowgate_relief |
|
| flowgate_value |
|
| flp |
Fraction of LP power ahead of reheater (Flp) |
| focal_depth |
The depth below the earth's surface of the earthquake's focal point |
| for |
Part of the LossProfile for an EnergyTransaction may be a loss for a Transmis... |
| for_mkt_measurement |
A measurement is made on the A side of a tie point |
| for_tie_point |
A measurement is made on the A side of a tie point |
| forbidden_region |
|
| forecast_type |
Load forecast area type |
| form_number |
Meter form designation per ANSI C12 |
| former_reference |
|
| forward_switching_date_time_interval |
The date when the switching to isolate equipment is performed |
| fossil_fuel |
A fuel allocation schedule shall have a fossil fuel |
| fossil_fuel_type |
The type of fossil fuel, such as coal, oil, or gas |
| fossil_fuels |
A thermal generating unit may have one or more fossil fuels |
| fover |
Wind turbine over frequency protection activation threshold (f... |
| fp |
Flow P9 (Fp9) |
| frame |
|
| framework_part |
Model frame of the model part |
| freq_resp |
Frequency Response Analysis |
| freq_set_point |
The present power system frequency set point for automatic generation control... |
| frequency |
|
| frequency_bias_factor |
The control area's frequency bias factor, in MW/0 |
| frequency_type |
|
| frequency_watt_curve_function |
|
| from_configuration |
|
| from_flowgate |
|
| from_mesh_impedance |
All mesh impedances between this 'to' and other 'from' transformer ends |
| from_mesh_impedances |
All mesh impedances between this 'to' and other 'from' transformer ends |
| from_phase |
Refer to the class description |
| from_sc |
|
| from_sctrade |
|
| from_sub_control_area |
|
| from_transformer_end |
From end this mesh impedance is connected to |
| from_transformer_end_info |
'from' transformer end datasheet this mesh impedance is calculated from |
| from_transition_state |
|
| from_winding |
|
| from_winding_insulations |
|
| ftr_type |
Type of rights being offered (product) allowed to be auctioned (option, oblig... |
| ftrs |
|
| fuel_adder |
Estimated Fuel Adder |
|
|
| fuel_allocation_end_date |
The end time and date of the fuel allocation schedule |
| fuel_allocation_schedules |
A thermal generating unit may have one or more fuel allocation schedules |
| fuel_allocation_start_date |
The start time and date of the fuel allocation schedule |
| fuel_cold_startup |
Verifiable Cold Start Up Fuel (MMBtu per start) |
|
|
| fuel_cost |
The cost in terms of heat value for the given type of fuel |
| fuel_cost_curve |
|
| fuel_demand_limit |
Fuel demand limit |
| fuel_dispatch_cost |
The cost of fuel used for economic dispatching which includes: fuel cost, tra... |
| fuel_eff_factor |
The efficiency factor for the fuel (per unit) in terms of the effective energ... |
| fuel_handling_cost |
Handling and processing cost associated with this fuel |
| fuel_heat_content |
The amount of heat per weight (or volume) of the given type of fuel |
| fuel_hot_startup |
Verifiable Hot Start Up Fuel (MMBtu per start) |
|
|
| fuel_intermediate_startup |
Verifiable Intermediate Start Up Fuel (MMBtu per start) |
|
|
| fuel_low_sustained_limit |
Minimum-Energy fuel, MMBtu/MWh |
|
|
| fuel_mixture |
Relative amount of the given type of fuel, when multiple fuels are being cons... |
| fuel_region |
|
| fuel_region_type |
The type of fuel region |
|
|
| fuel_source |
Values: Natural Gas Based Resource, Non Natural Gas Based Resource |
|
|
| fuel_sulfur |
The fuel's fraction of pollution credit per unit of heat content |
| fuel_supply_delay |
Fuel delay |
| fuel_supply_tc |
Fuel supply time constant |
| fuel_type |
The type of fuel, which also indicates the corresponding measurement unit |
| full_supply_level |
Full supply level, above which water will spill |
| fumigant_applied_date |
Date fumigant was last applied |
| fumigant_name |
Name of fumigant |
| function |
The function is an enumerated value that can be 'active', 'reactive', or 'VA'... |
| function_kind |
|
| funder |
Wind turbine under frequency protection activation threshold (f<sub... |
| furfural_dp |
Overall measure of furfural in oil and mechanical strength of paper |
| g |
Zero sequence magnetizing branch conductance (star-model) |
| g_ch |
Zero sequence mutual coupling shunt (charging) conductance, uniformly distrib... |
| g_per_section |
Positive sequence shunt (charging) conductance per section |
| gamma |
Extinction angle |
| ganged |
True if multi-phase switch controls all phases concurrently |
| gas_metering |
True if gas metering function is supported |
| gas_percent_above_low_sustained_limit |
Percentage of Fuel Index Price (gas) for operating above Low Sustained Limit ... |
| gas_percent_cold_startup |
Percentage of Fuel Index Price (gas) for cold startup |
|
|
| gas_percent_hot_startup |
Percentage of Fuel Index Price (gas) for hot startup |
|
|
| gas_percent_intermediate_startup |
Percentage of Fuel Index Price (gas) for intermediate startup |
|
|
| gas_percent_low_sustained_limit |
Percentage of FIP (gas) for operating at LSL |
|
|
| gas_price |
|
| gas_price_index |
The average natural gas price at a defined fuel region |
| gas_weight_per_tank |
Weight of gas in each tank of SF6 dead tank breaker |
| gate |
|
| gate_armed |
Association to a Gate that through a gate logic and input pin defines arming ... |
| gate_com_condition |
For the StageTrigger to active the set of protective actions the condition fo... |
| gate_enabled_condition |
Association to a Gate that through a gate logic and input pin defines enablin... |
| gate_input_pin |
Input to the gate |
| gate_output |
|
| gate_rate_limit |
Gate rate limit |
| gate_trigger |
The Gate result that trigger the StageTrigger and thereby executing the a set... |
| gate_upper_limit |
Gate upper limit |
| gateway |
Is the dotted decimal IPAddress of the first hop router |
| gatmax |
Gate opening limit maximum (Gatmax) (> GovHydroWPID |
| gatmin |
Gate opening limit minimum (Gatmin) (< GovHydroWPID |
| gch |
Positive sequence shunt (charging) conductance, uniformly distributed, of the... |
| gen_control_mode |
The unit control mode |
| gen_control_source |
The source of controls for a generating unit |
| gen_distribution_factor |
|
| gen_icompensation_for_gen_j |
Compensation of voltage compensator's generator for current flow out of this ... |
| gen_rated_p |
The hydro plant's generating rating active power for rated head conditions |
| gen_source_pump_discharge_reservoir |
Generators are supplied water from or pumps discharge water to an upstream re... |
| gen_unit_op_cost_curves |
A generating unit may have one or more cost curves, depending upon fuel mixtu... |
| gen_unit_op_schedule |
A generating unit may have an operating schedule, indicating the planned oper... |
| general_clearing |
|
| general_clearing_results |
|
| generating_bid |
|
| generating_bids |
|
| generating_unit |
|
| generating_unit_dynamic_values |
|
| generation_price |
Price of the commodity measured in base unit of currency per 'unitOfMeasure' |
| generation_price_ratio |
Ratio of 'generationPrice' to the "normal" price chosen by the commodity prov... |
| generation_provider |
|
| generator_performance_degree |
The Degree of Generator Performance (DGP) used for the unit |
| generic_action |
The generic action that is performed on the power system resource |
| generic_asset_model |
|
| generic_constraints |
|
| generic_non_linear_load_model_type |
Type of generic non-linear load model |
| geo_info_reference |
(if applicable) Reference to geographical information source, often external ... |
| gl_account |
General Ledger account code, must be a valid combination |
| gl_date_time |
Date and time line item will be posted to the General Ledger |
| gmax |
Maximum gate opening (Gmax) (> 0 and > GovHydro |
| gmin |
Minimum gate opening (Gmin) (>= 0 and < GovHydro1 |
| gmr |
Geometric mean radius |
| government_id |
Unique identifier for person relative to its governing authority, for example... |
| governor_control |
Governor control flag (Cflag) |
| governor_mpl |
Governor motor position limit |
| governor_scd |
Governor Speed Changer Droop |
| gross_capacity |
Total capacity of reservoir |
| gross_settlement |
MSS Load Following may select Net vs |
| gross_to_net_active_power_curves |
A generating unit may have a gross active power to net active power curve, de... |
| ground |
Ground on which this action is taken |
| ground_action |
Action taken with this ground |
| ground_trip |
Actual ground trip for this type of relay, if applicable |
| ground_trip_capable |
True if device has ground trip capability |
| ground_trip_normal_enabled |
True if normal status of ground trip is enabled |
| ground_trip_rating |
Ground trip rating |
| grounded |
(for Yn and Zn connections) True if the neutral is solidly grounded |
| grounded_end_short_circuit_tests |
All short-circuit test measurements in which this transformer end was short-c... |
| grounded_end_step |
Tap step number for the grounded end of the test pair |
| grounded_ends |
All ends short-circuited in this short-circuit test |
| grounded_equipment |
Equipment being grounded with this operation |
| grounding_action |
Action involving grounding operation on this conducting equipment |
| grounding_points |
free-form list of equipment to be grounded or other actions to be taken in or... |
| group_number |
Zero-relative sequence number of this group within a series of points; used w... |
| gtmxcl |
Maximum gate closing rate (Gtmxcl) |
| gtmxop |
Maximum gate opening rate (Gtmxop) |
| gv |
Nonlinear gain point 6, PU gv (Gv6) |
| h |
Turbine nominal head (H0) |
| hardware_id |
Hardware version |
| has_first_mutual_coupling |
Mutual couplings associated with the branch as the first branch |
| has_loss |
Part of the LossProfile for an EnergyTransaction may be a loss for a Transmis... |
| has_second_mutual_coupling |
Mutual couplings with the branch associated as the first branch |
| has_ventilation |
True if vault is ventilating |
| hazard |
|
| hazards |
All asset hazards at this location |
| hdam |
Turbine nominal head (hdam) |
| headline |
An abbreviated textual description of the alert issued |
| heat_input_curve |
A thermal generating unit may have a heat input curve |
| heat_input_eff |
Heat input - efficiency multiplier adjustment factor |
| heat_input_offset |
Heat input - offset adjustment factor |
| heat_rate_curve |
A thermal generating unit may have a heat rate curve |
| heat_recovery_boiler |
A combustion turbine may have a heat recovery boiler for making steam |
| heat_recovery_flag |
Flag that is set to true if the combustion turbine is associated with a heat ... |
| heating_offset |
Requested offset to apply to the normal heating setpoint at the time of the s... |
| heating_setpoint |
Requested heating set point |
| hedge_type |
Hedge type Obligation or Option |
| height |
Visible height of structure above ground level for overhead construction (e |
| hgen |
Inertia constant of generator (Hgen) (>= 0) |
| hhpmax |
Maximum control valve position (Hhpmax) |
| high_breakpoint_p |
The active power output level of the unit at which the given type of fuel is ... |
| high_control_limit |
High limit for secondary (AGC) control |
|
|
| high_level_limit |
High target level limit, above which the reservoir operation will be penalize... |
| high_limit |
The maximum allowable value |
| high_mw |
High end of the region definition |
|
|
| high_power_limit |
High power limit |
| high_pressure_synchronous_machine_dynamics |
High-pressure synchronous machine with which this cross-compound turbine gove... |
| high_side_min_operating_u |
The minimum operating voltage (uQmin in IEC 60909-0) at the high voltage side... |
| high_step |
Highest possible tap step position, advance from neutral |
| high_voltage_limit |
The bus bar's high voltage limit |
| high_voltage_override |
For locally controlled shunt impedances which have a voltage override feature... |
| hlim |
Stabilizer output limiter (HLIM) |
| hn |
Rated hydraulic head (Hn) |
| holder_id |
National identity number (or equivalent) of account holder |
| holder_name |
Name of account holder |
| holds_title_to_energy_products |
A Marketer holds title to an EnergyProduct |
| host_control_area |
|
| hot_int_time |
Hot-to-intermediate time (Seasonal) |
|
|
| hot_leg_lag_tc |
Hot leg lag time constant |
| hot_leg_steam_gain |
Hot leg steam gain |
| hot_leg_to_cold_leg_gain |
Hot leg to cold leg gain |
| hot_spot_temp |
Hotspot oil temperature |
| hot_standby_heat |
The amount of heat input per time unit required for hot standby operation |
| hot_standby_ramp |
The startup ramp rate in gross for a unit that is on hot standby |
| hot_start_time |
Hot start time |
| hour_ahead_sched_energy |
HASP results |
| hour_over_load_rating |
Overload rating for 1 hour |
| hourly_predispatch |
Indicates need to dispatch before the start of the operating hour |
| hourly_schedule |
Hourly Schedule (DA Energy Schedule) |
| humidity_at_sampling |
Operating ambient humidity (in percent) |
| hvdclook_up_table |
|
| hvgate |
Indicates if HV gate is active (HVgate) |
| hvlvgates |
Indicates if both HV gate and LV gate are active (HVLVgates) |
| hwtr |
Inertia constant of wind turbine rotor (HWTR) (>=... |
| hydro_generating_efficiency_curves |
A hydro generating unit has an efficiency curve |
| hydro_generating_unit |
A hydro generating unit has a tailbay loss curve |
| hydro_generating_units |
The hydro generating unit belongs to a hydro power plant |
| hydro_plant_storage_type |
The type of hydro power plant water storage |
| hydro_power_plant |
The hydro pump may be a member of a pumped storage plant or a pump for distri... |
| hydro_power_plants |
Generators discharge water to or pumps are supplied water from a downstream r... |
| hydro_pump |
The synchronous machine drives the turbine which moves the water from a low e... |
| hydro_pump_op_schedule |
The hydro pump has a pumping schedule over time, indicating when pumping is t... |
| hydro_pumps |
The hydro pump may be a member of a pumped storage plant or a pump for distri... |
| hydro_unit_water_cost |
The equivalent cost of water that drives the hydro turbine |
| hydrogen_pressure |
The hydrogen coolant pressure |
| hyst |
OEL pickup/drop-out hysteresis (HYST) |
| ia_ir_ratio |
Ratio of locked-rotor current to the rated current of the motor (Ia/Ir) |
| iban |
International bank account number defined in ISO 13616; for countries where I... |
| iccpinformation_message |
Informational message to be included in a Bilateral Table agreement |
| idc |
Converter DC current, also called Id |
| idc_inverter_control |
|
| idc_target_mkt_flow |
Energy Flow level that should be maintained according to the TLR rules as spe... |
| identified_object |
Identified object that this name designates |
| idle_loss |
Active power loss in pole at no power transfer |
| iefmax |
Minimum open circuit excitation voltage (Iefmax2) |
| iefmin |
Limiter (Iefmin) (< ExcELIN2 |
| ifd_base_type |
Excitation base system mode |
| ifdlim |
OEL timed field current limit (IFDLIM) |
| ifdmax |
OEL instantaneous field current limit (IFDMAX) |
| ifmn |
Minimum exciter current (IFMN) |
| ifmx |
Maximum exciter current (IFMX) |
| ign_angle_cont_inverter |
|
| ignition_fuel_type |
Type of ignition fuel |
| ignore_losses |
Provides an indication if losses are to be ignored for this zone |
| ignore_marginal_losses |
Provides an indication if marginal losses are to be ignored for this zone |
| ik_second |
Indicates whether initial symmetrical short-circuit current and power have be... |
| ikk |
Steady-state short-circuit current (in A for the profile) of generator with c... |
| ilr |
Exciter output current limit reference (ILR) |
| imax |
Major loop PI tag output signal upper limit (Imax) (> ExcHU |
| imaxdip |
Maximum current during voltage dip at the wind turbine terminals (i... |
| imbalance_energy_bias |
Imbalance Energy Bias (MW) by Time Period (5' only) |
|
|
| imin |
Major loop PI tag output signal lower limit (Imin) (< ExcHU |
| impacts |
|
| impedance |
Fault impedance |
| import_energy_transactions |
Energy is transferred between interchange areas |
| import_mwrating |
Import MW rating |
|
|
| import_sub_control_area |
Energy is transferred between interchange areas |
| imul |
AVR output voltage dependency selector (IMUL) |
| in_build |
The date Power System Project is in build stage |
| in_core_thermal_tc |
In-core thermal time constant |
| in_effect |
The interval for which this weather alert is in effect |
| in_plan |
The date Power System Project is in planning stage |
| in_service |
Specifies the availability of the equipment |
| in_service_date |
Date and time asset most recently put in service |
| in_transit_time |
The transition time from open to close |
| in_use_date |
In use dates for this asset |
| in_use_state |
Indication of whether asset is currently deployed (in use), ready to be put i... |
| inadvertent_account |
A control area can have one or more net inadvertent interchange accounts |
| incident |
|
| incident_hazard |
All hazards associated with this incident |
| incidents |
All incidents being addressed by this work |
| incremental_dataset |
|
| incremental_dataset_arg |
|
| incremental_dataset_arg_description |
|
| incremental_heat_rate_curve |
A thermal generating unit may have an incremental heat rate curve |
| incremental_maint_cost |
Incremental maintenance cost |
| incremental_oravail |
|
| ind_contract_right |
|
| ind_transmission_right_chain |
|
| individual_pnode |
|
| inductance |
Inductance of the DC line segment |
| inductive_rating |
Inductive reactance at maximum inductive reactive power |
| inertia |
Inertia constant of generator or motor and mechanical load (H) (> 0... |
| inflow_forecasts |
A reservoir may have a "natural" inflow forecast |
| init_op_mode |
Initial operating mode, with the following values: Automatic, Manual |
| initial_condition |
Condition of asset at last baseline |
| initial_delay |
For an LTC, the delay for initial tap changer operation (first step change) |
| initial_loss_of_life |
Percentage of initial life expectancy that has been lost as of the last life ... |
| initial_p |
Default initial active power which is used to store a powerflow result for t... |
| initial_reactive_capability_curve |
The default reactive capability curve for use by a synchronous machine |
| initially_used_by_synchronous_machines |
Synchronous machines using this curve as default |
| inlim |
Input limiter indicator |
| input |
Input value (x) for the lookup table function |
| input_signal |
Input signal switch (Flag) |
| input_signal_type |
Type of input signal (rotorAngularFrequencyDeviation, generatorElectricalPowe... |
| inspection_data_set |
|
| install_code |
Installation code |
| installation_date |
Date current installation was completed, which may not be the same as the in-... |
| installed_capacity |
Installed Capacity value |
|
|
| installed_date |
Date and time asset most recently installed |
| instance_set |
Dataset containing the data objects |
| instance_set_member |
Data objects contained in the dataset |
| instruction |
Instructions for performing this task |
| instruction_clearing |
|
| instruction_clearing_dop |
|
| instruction_clearing_dot |
|
| instruction_cost |
Total cost associated with changing the status of the resource |
| instruction_id |
Unique instruction id per instruction, assigned by the SC and provided to ADS |
| instruction_manual |
Reference manual or instruction book for this asset model |
| instruction_source |
instruction source for market quality results (INS, ACT) |
|
|
| instruction_start_time |
Time the resource should be at Pmin (for start ups) |
| instruction_time |
The date/time for the instruction |
| instruction_type |
Indicator of either a Start-Up or a Shut-Down |
| instructions |
|
| insulated |
True if conductor is insulated |
| insulation |
The type of insulation around the joint, classified according to the utility'... |
| insulation_kind |
Kind of insulation |
| insulation_material |
(if insulated conductor) Material used for insulation |
| insulation_pfstatus |
Status of Winding Insulation Power Factor as of statusDate: Acceptable, Minor... |
| insulation_resistance |
For testType, status of Winding Insulation Resistance as of statusDate |
| insulation_thickness |
(if insulated conductor) Thickness of the insulation |
| insulation_u |
Basic insulation level voltage rating |
| int_cold_time |
Intermediate-to-cold time (Seasonal) |
|
|
| int_start_time |
Intermediate start time |
| integer_parameter_value |
Integer parameter value |
| integral_gain |
Integral gain |
| intensity |
The intensity of the earthquake as defined by the Modified Mercalli Intensity... |
| intensity_kind |
Code representing the intensity of the weather condition |
| inter_tie |
|
| inter_tie_bid |
|
| inter_tie_clearing |
|
| inter_tie_dispatch_response |
|
| inter_tie_results |
|
| interchange_etcdata |
|
| interchange_schedule |
|
| interest |
Part of 'current' that constitutes the interest portion |
| interface_margin |
The margin for the interface |
|
|
| interharmonic |
Indication of a "harmonic" or "interharmonic" basis for the measurement |
| intermittent_resource_eligibility |
|
| internal_ca |
A Yes/No indication that this control area is contained internal to the syste... |
| internal_control_area |
|
| international_prefix |
(if applicable) Prefix used when calling an international number |
| interrupter_unit |
Interrupter controlled by this mechanism |
| interrupting_medium |
Interrupting medium |
| interrupting_rating |
Breaking capacity, or short circuit rating, is the maximum rated current whic... |
| interval |
Start and end time of an interval during which end device control actions are... |
| interval_blocks |
All blocks containing interval reading values with this type information |
| interval_date |
The date of which the settlement is run |
| interval_end_time |
The end of the time interval for which requirement is defined |
| interval_length |
Interval length |
| interval_number |
The sequence number of a time interval defined by the DispatchSchedule |
| interval_readings |
Interval reading contained in this block |
| interval_schedule |
Regular interval schedule containing this time point |
| interval_start_time |
The start of the time interval for which requirement is defined |
| inverse_time_flag |
Set true if the current relay has inverse time characteristic |
| invoice_type |
|
| iopoint |
ICCP point for a local measurement value source |
| iopoint_source |
Local merasurement value source for an ICCP point |
| ip_max |
Maximum allowable peak short-circuit current of busbar (Ipmax in IEC 60909-0) |
| iqh |
Maximum reactive current injection during dip (iqh1) |
| iqmax |
Maximum reactive current injection (iqmax) (> Win... |
| iqmin |
Minimum reactive current injection (iqmin) (< Win... |
| iqpost |
Post fault reactive current injection (iqpost) |
| irmax |
Maximum turbine speed/load reference bias (Irmax) (see parameter detai... |
| is_aggregated_res |
A flag to indicate if a resource is an aggregated resource |
| is_arm_connect |
True if the RCD switch has to be armed before a connect action can be initiat... |
| is_arm_disconnect |
True if the RCD switch has to be armed before a disconnect action can be init... |
| is_bankable |
True if this receipted payment is manually bankable, otherwise it is an elect... |
| is_cable |
If true, this spacing data describes a cable |
| is_coincident_trigger |
If true, this meter reading is the meter reading for which other coincident m... |
| is_connected |
True if this function is in the connected state |
| is_dctie |
Flag to indicated whether this Inter-tie is a DC Tie |
| is_debit |
True if 'amount' is a debit, false if it is a credit |
| is_delayed_discon |
If set true, the switch may disconnect the service at the end of a specified ... |
| is_disputed |
Disputed transaction indicator |
|
|
| is_dynamic_interchange |
Specifies whether the inter-tie resource is registered for the dynamic interc... |
| is_electric_vehicle |
True if the appliance is an electric vehicle |
| is_energy_limiting |
True if the energy usage is limited and the customer will be disconnected if ... |
| is_exterior_lighting |
True if the appliance is exterior lighting |
| is_free_sequence |
For a step, if isFreeSequence is set to false or is not specified, all of the... |
| is_generation_system |
True if the appliance is a generation system |
| is_hvac_compressor_or_furnace |
True if the appliance is HVAC compressor or furnace |
| is_infinite_duration |
Defines if the operational limit type has infinite duration |
| is_interior_lighting |
True if the appliance is interior lighting |
| is_irrigation_pump |
True if the appliance is an irrigation pump |
| is_local_auto_discon_op |
If set true and if disconnection can be operated locally, the operation happe... |
| is_local_auto_recon_op |
If set true and if reconnection can be operated locally, then the operation h... |
| is_managed_commercial_industrial_load |
True if the appliance is managed commercial or industrial load |
| is_net_gross_p |
Flag is set to true when output is expressed in net active power |
| is_networked |
Indication that station is part of a network of stations used to monitor weat... |
| is_pan |
If true, this is a premises area network (PAN) device |
| is_part_of_generator_unit |
Indicates whether the machine is part of a power station unit |
| is_percentage_limits |
Tells if the limit values are in percentage of normalValue or the specified U... |
| is_polygon |
Defines whether or not the diagram objects points define the boundaries of a ... |
| is_polymer |
If true, the arrester has a polymer housing, porcelain otherwise |
| is_pool_pump_spa_jacuzzi |
True if the appliance is a pool, pump, spa or jacuzzi |
| is_pre_pay |
If true, the customer is a pre-pay customer for the specified service |
| is_profiled |
A flag indicating whether there is a profile data associated with the PTB |
| is_public |
If true, this Pnode is public (prices are published for DA/RT and FTR markets... |
| is_regulating |
If true the regulator is put in-service, otherwise out-of-service (no regulat... |
| is_remote_auto_discon_op |
If set true and if disconnection can be operated remotely, then the operation... |
| is_remote_auto_recon_op |
If set true and if reconnection can be operated remotely, then the operation ... |
| is_sdp |
If true, this usage point is a service delivery point, i |
| is_simple_misc_load |
True if the appliance is a simple miscellaneous load |
| is_single_phase |
If true, it is a single phase switch |
| is_slack |
|
| is_smart_appliance |
True if the appliance is a smart appliance |
| is_smart_inverter |
If true, there is a communicating inverter present |
| is_solid_state |
If true, this is a solid state end device (as opposed to a mechanical or elec... |
| is_strand_fill |
True if wire strands are extruded in a way to fill the voids in the cable |
| is_strip_and_baseboard_heater |
True if the appliance is a stip or baseboard heater |
| is_tcul |
Whether this tap changer has under load tap changing capabilities |
| is_unganged |
If true, the switch is not ganged (i |
| is_virtual |
If true, this usage point is virtual, i |
| is_water_heater |
True if the appliance is a water heater |
| isfreq |
Selector for frequency/shaft speed input (isFreq) |
| isolation_area |
free-form description of the area to be isolated by the switching |
|
|
| isolation_points |
free-form list of equipment to be operated or other actions to be taken in or... |
| isoupper_layer |
Application layer used with the certificate for mutual authentication |
| issue_date_time |
Date and time bill was issued to client |
| issued_by_supervisor |
Supervisor that issued this safety document |
| issued_date_time |
Date and time when the crew was given the instruction to execute the action; ... |
| issued_safety_documents |
All safety documents issued by this supervisor |
| issued_to_supervisor |
Supervisor to whom this safety document is issued |
| issuer |
Issuer of this document |
| issuer_id |
Unique identifier of the business entity originating an end device control |
| issuer_identification_number |
Unique transaction reference prefix number issued to an entity by the Interna... |
| issuer_name |
Represents the CA that issued the certificate |
| issuer_tracking_id |
Identifier assigned by the initiator (e |
| isw |
Digital/analogue output switch (Isw) |
| itfpu |
OEL timed field current limiter pickup level (ITFPU) |
| itu_phone |
Phone number according to International Telecommunication Union (ITU) E |
| j |
Selector (J) |
| jpa_reference |
Joint pole agreement reference number |
| jumped_equipments |
Conducting equipment is affected when the jumper action connects one or both ... |
| jumper |
Jumper on which this action is taken |
| jumper_action |
Action taken with this jumper |
| jumping_action |
Jumper action involving jumping operation on this conducting equipment |
| justification |
Justification for 'rank' |
| k |
Governor gain (K) |
| k_ec |
Voltage regulator input limit (K1ec) |
| ka |
Acceleration limiter gain (Ka) |
| kac |
Fuel system feedback (KAC) |
| kan |
Discontinuous controller gain (KAN) |
| kb |
Second stage regulator gain (KB) (> 0) |
| kc |
Penstock loss coefficient (due to friction) (Kc) |
| kca |
Acceleration control integral gain (Kca) |
| kcd |
OEL cooldown gain (KCD) |
| kce |
Ceiling factor (KCE) |
| kci |
Exciter output current limit adjustment (KCI) (> ... |
| kcl |
Exciter output current limit adjustment (Kcl) (> 0) |
| kd |
Drop governor gain (Kd) |
| kdc |
Derivative gain of pressure regulator (Kdc) |
| kdgov |
Governor derivative gain (Kdgov) |
| kdpm |
Lead lag gain (KDPM) |
| kdr |
Voltage regulator derivative gain (KDR) (>= 0) |
| kdroop |
(Kdroop) (>= 0) |
| kdrt |
Drive train stiffness (kdrt) |
| kdtd |
Gain for active drive train damping (KDTD) |
| ke |
Gain of the power controller (Ke) |
| keep_alive_time |
Indicates the default interval at which TCP will check if the TCP connection ... |
| kefd |
Field voltage feedback gain (Kefd) |
| ketb |
Gain (Ketb) |
| ketl |
Terminal voltage limiter gain (KETL) |
| kf |
Fuel system feedback (Kf) |
| kfb |
Gain associated with optional integrator feedback input signal to UEL (K</... |
| kfcor |
Gain of the frequency corrector (Kfcor) |
| kff |
Pre-control gain constant of the inner loop field regulator (K... |
| kg |
Gate servo gain (Kg) |
| kgob |
P controller gain (Kgob) |
| kh |
Exciter field current feedback gain (KH) (>= 0) |
| khp |
Fraction of total turbine output generated by HP part (Khp) |
| ki |
Isochronous Governor Gain (Ki) |
| kia |
Voltage regulator integral gain (KIA) (>= 0) |
| kic |
Integral gain of pressure regulator (Kic) |
| kif |
Exciter internal reactance (KIF) |
| kigov |
Governor integral gain (Kigov) |
| kii |
Field current regulator integral gain (Kii) |
| kiload |
Load limiter integral gain for PI controller (Kiload) |
| kim |
Voltage regulator integral gain output (KIM) |
| kimw |
Power controller (reset) gain (Kimw) |
| kind |
Kind of asset |
| kiomega |
Speed PI controller integration gain (KIomega) |
| kip |
Integral gain of pressure feedback regulator (Kip) |
| kiq |
Reactive power PI controller integration gain (KI,q) |
| kir |
Voltage regulator integral gain (KIR) (>= 0) |
| kirr |
Integral gain in rotor resistance PI controller (KIrr</i... |
| kit |
Integral gain of electro-hydraulic regulator (Kit) |
| kiu |
Voltage PI controller integration gain (KI,u) |
| kivdc |
Integral gain of the DC voltage regulator (Kivdc) |
| kiwpp |
Plant P controller integral gain (KIWPp) |
| kiwppmax |
Maximum PI integrator term (KIWPpmax) (> WindPlan... |
| kiwppmin |
Minimum PI integrator term (KIWPpmin) (< WindPlan... |
| kiwpx |
Plant Q controller integral gain (KIWPx) |
| kiwpxmax |
Maximum reactive power/voltage reference from integration (KIW... |
| kiwpxmin |
Minimum reactive power/voltage reference from integration (KIW... |
| kj |
AVR gain (Kj) (> 0) |
| kl |
Exciter field voltage lower limit parameter (KL) |
| klir |
OEL input gain (KLIR) |
| klp |
Fraction of total turbine output generated by HP part (Klp) |
| klr |
Exciter output current limiter gain (KLR) |
| kls |
Gain (Kls) (> 0) |
| klus |
Limiter gain (KLUS) |
| klv |
Gain used in the minimum field voltage limiter loop (Klv) |
| km |
Forward gain constant of the inner loop field regulator (KM</s... |
| kmp |
Second gain coefficient of intercept valves characteristic (Kmp2) |
| kmx |
Gain (KMX) |
| kn |
Excitation control system stabilizer gain (KN) (>... |
| knee_point_current |
Maximum primary current where the CT still displays linear characteristicts |
| knee_point_voltage |
Maximum voltage across the secondary terminals where the CT still displays li... |
| koi |
Gain Over excitation limiter (KOI) |
| komega |
Shaft speed power input gain (Komega) |
| komegacor |
Gain of the speed governor (Kwcor) |
| komegafilt |
Filter gain for generator speed measurement (Komegafilt<... |
| kp |
PID proportional gain (Kp) |
| kpa |
Voltage regulator proportional gain (KPA) (> 0 if... |
| kpc |
Proportional gain of pressure regulator (Kpc) |
| kpe |
Electric power input gain (KPE) |
| kpf |
Frequency deviation coefficient for active power (Kpf</i... |
| kpfilt |
Filter gain for power measurement (Kpfilt) |
| kpgov |
Governor proportional gain (Kpgov) |
| kpload |
Load limiter proportional gain for PI controller (Kpload) |
| kpm |
Voltage regulator proportional gain output (KPM) |
| kpomega |
Speed PI controller proportional gain (KPomega) |
| kpp |
Proportional gain of pressure feedback regulator (Kpp) |
| kpq |
Reactive power PI controller proportional gain (KP,q... |
| kpqu |
Partial derivative of reactive current limit (Kpqu) ... |
| kpr |
Voltage regulator proportional gain (KPR) (> 0 if... |
| kprr |
Proportional gain in rotor resistance PI controller (KPrr</sub... |
| kpss |
PSS gain (KPSS) |
| kpt |
Proportional gain of electro-hydraulic regulator (Kpt) |
| kpu |
Voltage PI controller proportional gain (KP,u) |
| kpvdc |
Proportional gain of the DC voltage regulator (Kpvdc) |
| kpwpp |
Plant P controller proportional gain (KPWPp) |
| kpwpx |
Plant Q controller proportional gain (KPWPx) |
| kpx |
Pitch cross coupling gain (KPX) |
| kq |
Frequency coefficient for reactive power (Kq4) (not... |
| kqf |
Frequency deviation coefficient for reactive power (Kqf<... |
| kqi |
PI controller gain of integral component (Kqi) |
| kqob |
Rate of rise of the reactive power (Kqob) |
| kqp |
PI controller gain (Kqp) |
| kqv |
Voltage scaling factor for UVRT current (Kqv) |
| kr |
Constant associated with regulator and alternator field power supply (K</i... |
| kramp |
OEL ramped limit rate (KRAMP) |
| krc |
Maximum variation of fuel flow (Krc) |
| krvecc |
Feedback enabling (KRVECC) |
| ks |
Saturation loading correction factor (Ks) (>= 0) |
| ksh |
Pressure loss due to flow friction in the boiler tubes (Ksh) |
| ksi |
Gain of radiation shield (Ksi) |
| kt |
Temperature limiter gain (Kt) |
| ktm |
Compressor gain (Ktm) |
| kturb |
Turbine gain (Kturb) |
| kuc |
UEL centre setting (KUC) |
| kuf |
UEL excitation system stabilizer gain (KUF) |
| kui |
UEL integral gain (KUI) |
| kul |
UEL proportional gain (KUL) |
| kur |
UEL radius setting (KUR) |
| kv |
Fast raise/lower contact setting (KV) (> 0) |
| kvd |
Voltage regulator derivative gain (Kvd) |
| kvfif |
Rate feedback signal flag (KVFIF) |
| kvi |
Voltage regulator integral gain (Kvi) |
| kvp |
Voltage regulator proportional gain (Kvp) |
| kvphz |
V/Hz limiter gain (Kvphz) |
| kwppref |
Power reference gain (KWPpref) |
| kwpqref |
Reactive power reference gain (KWPqref) |
| kwpqu |
Plant voltage control droop (KWPqu) |
| kx |
Gain (Kx) |
| ky |
Coefficient of transfer function of fuel valve positioner (Ky) |
| lab_test_data_set |
Results from lab testing done on specimen |
| label_id |
labelID - an ID for a set of apnodes/pnodes used in a CRR market |
|
|
| labor_cost |
Total labor costs associated with the work task |
| labor_duration |
Time required to perform work |
| labor_hours |
Hours of labor expended under work task |
| labor_items |
|
| labor_rate |
The labor rate applied for work |
| lamp_kind |
Lamp kind |
| lan |
Address on local area network |
| land_properties |
|
| land_property |
|
| land_property_roles |
|
| landline_phone |
Landline phone number |
| language |
The language in which the address is specified, using ISO 639-1 two digit lan... |
| last_bill_amount |
The last amount that will be billed to the customer prior to shut off of the ... |
| last_calibration_date |
(if applicable) Date the tool was last calibrated |
| last_credit |
Details of the last credit transaction performed on this account |
| last_debit |
Details of the last debit transaction performed on this account |
| last_modified |
Indication of the last time this item was modified/versioned |
| last_modified_date_time |
Date and time this document was last modified |
| last_name |
Person's last (family, sir) name |
| last_payment_amt |
Amount of the last payment received from the customer |
| last_payment_date |
Date of the last payment received from the customer |
| last_update_date |
The date of the last update related to this market object |
| latest_date_time_to_call |
Latest date time to call the customer |
| latest_sched_minutes |
This indicates the latest schedule minutes (e |
| latest_sched_mkt_type |
This indicates the latest schedule market type a contract can be applied to |
| ldref |
Load limiter reference value (Ldref) |
| leakage_impedance |
Leakage impedance measured from a positive-sequence or single-phase short-cir... |
| leakage_impedance_zero |
Leakage impedance measured from a zero-sequence short-circuit test |
| leakage_reactance |
As of statusDate, the leakage reactance measured at the "from" winding with t... |
| left_digit_count |
Number of digits (dials on a mechanical meter) to the left of the decimal pla... |
| length |
Segment length for calculating line section capabilities |
| length_from_terminal |
The length to the place where the clamp is located starting from side one of ... |
| level |
The level of the resource element in the hierarchy of resource elements (recu... |
| level_vs_volume_curves |
A reservoir may have a level versus volume relationship |
| lfac |
Loading factor (Lfac) |
| lifecycle_date |
|
|
|
| lifecycle_state |
Current lifecycle state of asset |
| lifetime_fault_operations |
Total breaker fault operations to date |
| lifetime_motor_starts |
Total motor starts to date |
| lifetime_total_operations |
Total breaker operations to date (including fault and non-fault) |
| light_rating |
Power rating of light |
| lightning_impulse_discharge_voltage |
Residual voltage during an 8x20 microsecond current impulse at the nominal di... |
| likelihood_of_failure |
Likelihood of asset failure on a scale of 1(low) to 100 (high) |
| limit_dependency_model |
The limit dependency models which are used to calculate this limit |
| limit_flag |
Limit flag ('Maximum', 'Minimum') |
| limit_indicator |
indicate which limit is the constraints |
|
|
| limit_percent |
The scaling of the operational limit in percent |
| limit_scaling_limit |
|
| limit_scaling_percent |
The associated source limit is scaled by this value to compute the limit of t... |
| limit_set |
The set of limits |
| limit_sets |
A measurement may have zero or more limit ranges defined for it |
| limit_type |
The type of limit the value represents |
|
|
| limit_voltage |
Maximum allowed regulated voltage on the PT secondary, regardless of line dro... |
| limits |
|
| line |
Transaction amount, rounding, date and note for this transaction line |
| line_amount |
Amount due for this line item |
| line_discharge_class |
Determines the arrester energy discharge capability |
| line_drop_compensation |
If true, the line drop compensation is to be applied |
| line_drop_r |
Line drop compensator resistance setting for normal (forward) power flow |
| line_drop_x |
Line drop compensator reactance setting for normal (forward) power flow |
| line_faults |
The line faults of the line segment |
| line_grounding_action |
Ground action involving clamp usage (for the case when the ground is applied ... |
| line_jumping_action |
Jumper action involving clamp usage (for the case when the jumper is applied ... |
| line_number |
Line item number on invoice statement |
| line_version |
Version number of the bill run |
| linear_coefficient |
Loss estimate linear coefficient |
|
|
| lines |
The lines within the sub-geographical region |
| linked_bids_identification |
Unique identification associated with all linked bids |
| lmax |
Ambient temperature load limit (Lmax) |
| lmp |
5 min weighted average LMP; the Location Marginal Price of the Pnode for whic... |
| lmpmfinal_flag |
|
| lmpmflag |
LMPM flag: indicates whether the resource is subject to the LMPM test (Yes/No... |
| load_aggregate |
Aggregate load to which this aggregate static load belongs |
| load_area |
The LoadArea where the SubLoadArea belongs |
| load_bid |
|
| load_bids |
|
| load_break |
True if switch has load breaking capabiity |
| load_distribution_factor |
|
| load_dump_rating |
The Load Dump Rating for the branch |
|
|
| load_dynamics |
Load dynamics model used to describe dynamic behaviour of this energy consume... |
| load_following |
Indication that this particular MSSA participates in the Load Following funct... |
| load_following_down_mss |
Certifies resources for use in MSS Load Following Down |
|
|
| load_following_inst |
|
| load_following_mw |
Load Following MW Positive for follow-up and negative for follow-down |
|
|
| load_following_operator_input |
|
| load_following_up_mss |
Certifies resources for use in MSS Load Following Up |
|
|
| load_forecast |
Load Prediction/Forecast (MW), by Time Period (5', 10', 15') |
|
|
| load_group |
Group of this ConformLoad |
| load_groups |
The Loadgroups in the SubLoadArea |
| load_mgmt |
Load management code |
| load_motor |
Aggregate motor (dynamic) load associated with this aggregate load |
| load_ratio |
|
| load_red_initiation_cost |
load reduction initiation cost |
|
|
| load_red_initiation_time |
load reduction initiation time |
|
|
| load_reduction_price_curve |
|
| load_reduction_time_curve_type |
type of the curve: Possible values are but not limited to: |
|
|
| load_response |
The load response characteristic of this load |
| load_rollover_flag |
load change flag |
|
|
| load_static |
Aggregate static load associated with this aggregate load |
| load_user_defined |
Proprietary user-defined model with which this parameter is associated |
| loadinc |
Valve position change allowed at fast rate (Loadinc) |
| local_ca |
Indication that this control area is the local control area |
| local_control_kind |
Kind of local controller |
| local_number |
Main (local) part of this telephone number |
| local_off_level |
Upper control setting |
| local_on_level |
Lower control setting |
| local_override |
True if the locally controlled capacitor has voltage override capability |
| local_reference |
The Local Reference attribute specifies a value agreed upon between sender an... |
| local_reliability_area |
|
| local_time_zone |
Local time zone |
| locale |
Locale designating language to use in communications with this customer |
| located_on |
A transmission product is located on a transmission path |
| location |
Location of this power system resource |
| location_condition |
Description of the conditions of the location where the asset resides |
| location_for |
A transmission product is located on a transmission path |
| location_grants |
All location grants this land property has |
| locations |
The spatail description of a piece of property |
| locked |
If true, the switch is locked |
| log_time_stamp |
|
| login_id |
Login ID |
|
|
| login_role |
Assigned roles (these are roles with either Read or Read/Write privileges on ... |
| long_pf |
Generating unit long term economic participation factor |
| long_term_rating |
The Long Term Rating for the branch |
|
|
| lookup_table_function_type |
Type of the lookup table function |
| loss |
Load losses from a positive-sequence or single-phase short-circuit test |
| loss_clearing |
|
| loss_clearing_results |
|
| loss_factor |
Loss penalty factor |
| loss_lmp |
Loss component of Location Marginal Price (LMP) in monetary units per MW |
| loss_mw |
|
| loss_penalty_factor |
|
| loss_percentage |
Loss percentage |
|
|
| loss_profiles |
An EnergyTransaction may have a LossProfile |
| loss_zero |
Load losses from a zero-sequence short-circuit test |
| lot |
(if applicable) Name, identifier, or description of the lot in which work is ... |
| lot_number |
Lot number for this asset |
| low_breakpoint_p |
The active power output level of the unit at which the given type of fuel is ... |
| low_control_limit |
Low limit for secondary (AGC) control |
|
|
| low_level_limit |
Low target level limit, below which the reservoir operation will be penalized |
| low_limit |
The minimum allowable value |
| low_mw |
Low end of the region definition |
| low_power_limit |
Low power limit |
| low_pressure_alarm |
Gas or air pressure at or below which a low pressure alarm is generated |
| low_pressure_lock_out |
Gas or air pressure below which the breaker will not open |
| low_pressure_synchronous_machine_dynamics |
Low-pressure synchronous machine with which this cross-compound turbine gover... |
| low_step |
Lowest possible tap step position, retard from neutral |
| low_voltage_limit |
The bus bar's low voltage limit |
| low_voltage_override |
For locally controlled shunt impedances which have a voltage override feature... |
| lower_limit |
resource energy ramping lower limit |
|
|
| lower_ramp_rate |
Maximum Dn ramp rate in MW/min |
|
|
| lower_reg_margin_reqt |
Lower regulating margin requirement in MW, the amount of generation that can ... |
| lp |
Transient reactance (Lp) |
| lpi |
Maximum negative power error (Lpi) |
| lpp |
Subtransient reactance (Lpp) |
| lps |
Maximum positive power error (Lps) |
| ls |
Steady state voltage index for active power (LS) |
| lsat |
Integrator limiter (LSAT) |
| lsmax |
Limiter (LSMAX) (> Pss2ST |
| lsmin |
Limiter (LSMIN) (< Pss2ST |
| lt |
Transient voltage index for active power (LT) |
| ltc_control_flag |
ltc enable flag |
|
|
| ltc_flag |
Specifies whether or not a TapChanger has load tap changing capabilities |
| lthres |
Threshold value (Lthres) |
| ltrate |
Maximum long term fuel valve opening rate (Ltrate) |
| lumpy_indicator |
The "Lumpy Flag"(Y/N) indicates whether the resource that sets the price is ... |
| lus |
Setpoint (LUS) |
| lvgate |
Indicates if LV gate is active (LVgate) |
| m |
(m) |
| m_name |
Middle name(s) or initial(s) |
| m_rid |
Master resource identifier issued by a model authority |
| m_ttr |
Mean time to repair (MTTR - hours) |
| m_var |
Unit reactive power generation in MVAR |
|
|
| m_varflow |
The MVAR flow on the branch |
|
|
| m_varinjection |
The injection of reactive power of the filter bank in the NA solution or VCS ... |
| mac |
MAC (Media Access Control) address |
| macro_period |
Time period of interest that reflects how the reading is viewed or captured o... |
| mag_base_u |
The reference voltage at which the magnetizing saturation measurements were m... |
| mag_sat_flux |
Core magnetizing saturation curve knee flux level |
| magnitude |
The magnitude of the earthquake as defined on the Moment Magnitude (Mw</... |
| mailed_date |
Date on which the customer billing statement/invoice was printed/mailed |
| main_address |
Main address of the location |
| main_fuel_type |
Type of main fuel |
| maint_code |
Code for the type of maintenance performed |
| major |
major release level for this version |
| major_charge_group |
|
| major_version |
The universal CIM version name describing a consistent set of packages |
| making_capacity |
The highest value of current the switch can make at the rated voltage under s... |
| manual_replace_indicator |
Switch Manual Replace Indicator |
| manual_to_avr |
Time delay required when switching from Manual to Automatic Voltage Regulatio... |
| manually_blocked |
Manually Blocked Indicator (Yes/No) |
| manually_sched_rmrmw |
The lower of the original pre-dispatch or the AC run schedule (Also known as ... |
| manufactured_date |
Date the asset was manufactured |
| manufacturer |
Manufacturer of this asset model |
| margin_percent |
Used to show the Margin % result of the Impact test |
|
|
| marginal_clearing_price |
Locational Marginal Price (LMP) ($/MWh) |
|
|
| marginal_resource_indicator |
Indicator (Yes / No) that this resource set the price for this dispatch / sch... |
| marked_indicator |
True if work location has been marked, for example for a dig area |
| market |
|
| market_actual_event |
All actual events that trigger this market run |
| market_approval_time |
Approved time for case |
| market_approved_status |
Set to true when the plan is approved by authority and becomes the official p... |
| market_case_clearing |
|
| market_code |
|
| market_date |
The date represents the NextMarketDate for which the load response bids apply... |
| market_document |
|
| market_end_time |
The end time defined as the end of the market, market end time |
| market_evaluation_point |
|
| market_factors |
|
| market_invoice |
|
| market_invoice_line_item |
|
| market_invoice_line_items |
|
| market_ledger |
|
| market_ledger_entries |
|
| market_ledger_entry |
|
| market_object_status |
|
| market_participant |
|
| market_participation_flag |
Market Participation flag: indicates whether the resource participate in the ... |
| market_person |
|
| market_plan |
A market plan has a number of markets (DA, HA, RT) |
| market_product |
|
| market_product_clearing |
|
| market_product_type |
Market product type examples: |
|
|
| market_products |
|
| market_qualification_requirements |
|
| market_region |
|
| market_region_results |
|
| market_results |
|
| market_role |
|
| market_run |
|
| market_sep_flag |
Market Separation Flag |
|
|
| market_service_type |
Choices are: |
|
|
| market_skills |
|
| market_start_time |
The start time defined as the beginning of the market, market start time |
| market_statement |
|
| market_statement_line_item |
|
| market_type |
The market type, Day Ahead Market or Real Time Market |
| marking_instruction |
Instructions for marking a dig area, if applicable |
| master_scheduling_coordinator_flag |
Flag to indicate that the SC representing the Resource is the Master SC |
| material |
Conductor material |
| material_items |
The material items that are required to perform the work task |
| material_kind |
Material this structure is made of |
| materiall_cost |
Total material costs associated with the work task |
| max |
Output limit (max) |
| max_allowed_target_value |
Maximum allowed target value (RegulatingControl |
| max_alpha |
Maximum firing angle |
| max_angle_diff |
The maximum allowable voltage vector phase angle difference across the open d... |
| max_base_load |
Maximum Base Load (MW), per Participating Load Resource |
| max_base_self_sched_qty |
Maximum base self schedule quantity |
| max_coverage |
The maximum percentage coverage |
| max_dependable_cap |
Maximum Dependable Capacity (MNDC) |
| max_deployment_time |
Maximum Deployment time (seconds) |
| max_economic_mw |
Economic Maximum MW |
|
|
| max_economic_p |
Maximum high economic active power limit, that should not exceed the maximum ... |
| max_emergency_mw |
Power rating available for unit under emergency conditions greater than or eq... |
| max_error_rate_p |
Active power maximum error rate limit |
| max_expost_capacity |
|
| max_freq_diff |
The maximum allowable frequency difference across the open device |
| max_fuel_allocation |
The maximum amount of fuel that is allocated for consumption for the schedule... |
| max_gamma |
Maximum extinction angle |
| max_head_max_p |
Maximum efficiency active power at maximum head conditions |
| max_idc |
The maximum direct current (Id) on the DC side at which the converter should ... |
| max_ifault |
Maximum fault current this device will contribute, in per-unit of rated curre... |
| max_initial_sym_sh_ccurrent |
Maximum initial symmetrical short-circuit currents (Ik" max) in A (Ik" = Sk... |
| max_limit |
Maximum Limit (MW) |
|
|
| max_load_red_times_per_day |
Maximum Number of Daily Load Curtailments |
| max_load_reduction |
maximum load reduction |
| max_min_load_cost |
The registered maximum Minimum Load Cost of a Generating Resource registered ... |
| max_modulation_index |
The maximum quotient between the AC converter voltage (Uc) and DC voltage (Ud... |
| max_mw |
Maximum MW limit |
|
|
| max_mwallocation |
Maximum MW for the Source/Sink for the Allocation |
|
|
| max_net_dependable_capacity |
Maximum Net Dependable Capacity |
|
|
| max_on_time |
Maximum on time after start up |
| max_operating_p |
This is the maximum operating active power limit the dispatcher can enter for... |
| max_p |
Maximum active power of the injection |
| max_power_loss |
Maximum allowed apparent power loss |
| max_pumping_level |
max pumping level of a hydro pump unit |
|
|
| max_q |
Maximum reactive power limit |
| max_r_to_x_ratio |
Maximum ratio of positive sequence resistance of Network Feeder to its positi... |
| max_ramp_rate |
maximum ramp rate |
|
|
| max_ratio |
Maximum ratio between the primary and secondary current |
| max_real_power_limiting |
If set to TRUE, the maxRealPowerLimiting function is supported |
| max_reduction_time |
Maxiimum Load Reduction Time (min), per Participating Load Resource |
| max_self_sched_mw |
Maximum amount of self schedule MWs allowed for an embedded control area |
| max_shutdown_time |
Maximum time this device can be shut down |
| max_start_ups_per_day |
maximum start ups per day |
|
|
| max_sufficiency_index |
Region requirement maximum limit |
|
|
| max_surface_wind_speed |
The maximum surface wind speed of the cyclone during the time interval |
| max_switch_operation_count |
IdmsShuntImpedanceData |
| max_u |
Maximum voltage limit for the unit |
| max_udc |
The maximum voltage on the DC side at which the converter should operate |
| max_value |
Normal value range maximum for any of the MeasurementValue |
| max_valve_current |
The maximum current through a valve |
| max_volt_diff |
The maximum allowable difference voltage across the open device |
| max_weekly_deployment |
Maximum weekly deployments |
| max_weekly_energy |
Maximum weekly Energy (Seasonal) |
|
|
| max_weekly_starts |
Maximum weekly starts (seasonal parameter) |
|
|
| max_yvalue |
The maximum value of the DERMonitorableParameter during the time interval |
| max_z_to_z_ratio |
Maximum ratio of zero sequence impedance to its positive sequence impedance (... |
| maxerr |
Maximum value for speed error signal (maxerr) (> GovCT1 |
| maximum_active_power |
The maximum active power flow |
| maximum_allowable_spinning_reserve |
Maximum allowable spinning reserve |
| maximum_angle |
The maximum phase angle shift of the phase shifter |
|
|
| maximum_capacity |
maximum capacity |
| maximum_economic_mw |
Maximum high economic MW limit, that should not exceed the maximum operating ... |
| maximum_emergency_ind |
True if maximum emergency limit activated; false otherwise |
| maximum_mw |
The maximum active power generation of the unit in MW |
|
|
| maximum_operating_limit |
This is the maximum operating MW limit the dispatcher can enter for this unit |
| maximum_reactive_power |
The maximum reactive power flow |
| maximum_schedule_quantity |
Maximum schedule MW quantity |
|
|
| maximum_sections |
The maximum number of sections that may be switched in for this phase |
| maximum_service_hours |
Maximum service hours |
|
|
| maximum_startups |
Maximum startups |
|
|
| mdfslim |
Limitation of type 3 stator current (MDFSLim) |
| measurement |
Measurement to which this calculation method hierarchy applies |
| measurement_action |
The measurement action that is performed on the measurement |
| measurement_calculator |
Result of the calculation used as input to a gate |
| measurement_calculator_input |
|
| measurement_kind |
Identifies "what" is being measured, as refinement of 'commodity' |
| measurement_type |
Specifies the type of measurement |
| measurement_value |
A MeasurementValue has a MeasurementValueQuality associated with it |
| measurement_value_quality |
A MeasurementValue has a MeasurementValueQuality associated with it |
| measurement_value_source |
A reference to the type of source that updates the MeasurementValue, e |
| measurement_values |
|
| measurements |
The measurements associated with this power system resource |
| measuring_period |
Time attribute inherent or fundamental to the reading value (as opposed to 'm... |
| mech_power_sensor_lag |
Mechanical power sensor lag |
| mechanical_load_dynamics |
Mechanical load model associated with this synchronous machine model |
| mechanical_load_user_defined |
Proprietary user-defined model with which this parameter is associated |
| mechanism_kind |
Kind of breaker operating mechanism |
| medium |
Medium with which this asset is filled |
| mediums |
|
| meeting_interval |
Date and time reserved for appointment |
| melmax |
Minimum excitation limit value (MELMAX) |
| merchant_account |
Merchant account this vendor shift periodically debits (based on aggregated t... |
| merchant_accounts |
All merchant accounts instantiated as a result of this merchant agreement |
| merchant_agreement |
Merchant agreement that instantiated this merchant account |
| merchant_debit_amount |
The amount that is to be debited from the merchant account for this vendor sh... |
| message |
|
| mesu |
Voltage input time constant (MESU) (>= 0) |
| meter |
Meter for this vending transaction |
| meter_load_following |
Meter Sub System Load Following |
| meter_multipliers |
All multipliers applied at this meter |
| meter_read_schedule |
Meter read schedule for which the time schedule applies |
| meter_reading |
Meter reading containing this interval block |
| meter_readings |
All meter readings obtained from this usage point |
| meter_replacement_work_tasks |
All work tasks on replacement of this old meter |
| meter_service_work_task |
All non-replacement work tasks on this meter |
| meter_service_work_tasks |
All meter service work tasks at this usage point |
| metered_sub_system |
|
| metered_value |
Flag indicated that the load reduction is metered |
| meters_affected |
The updated number of meters affected by the outage as reported by the OMS wi... |
| meters_served |
defines the number of meters served in the defined area |
| method |
The response method (e |
| method_type |
method of notification such as phone call, email, letter, door hanger, text m... |
| metrology |
True if metrology function is supported |
| metrology_requirements |
All metrology requirements for this usage point |
| micr_number |
The magnetic ink character recognition number printed on the cheque |
| min_allowed_target_value |
Minimum allowed target value (RegulatingControl |
| min_alpha |
Minimum firing angle |
| min_amount |
The minimum amount that has to be paid at any transaction towards settling th... |
| min_coverage |
The minimum percentage coverage |
| min_dispatch_time |
Minimum number of consecutive hours a resource shall be dispatched if bid is ... |
| min_economic_mw |
Economic Minimum MW |
|
|
| min_economic_p |
Low economic active power limit that shall be greater than or equal to the mi... |
| min_emergency_mw |
Minimum power rating for unit under emergency conditions, which is less than ... |
| min_error_rate_p |
Active power minimum error rate limit |
| min_expost_capacity |
|
| min_fuel_allocation |
The minimum amount of fuel that is allocated for consumption for the schedule... |
| min_gamma |
Minimum extinction angle |
| min_head_max_p |
Maximum efficiency active power at minimum head conditions |
| min_hourly_block |
The minimum hourly block for an Inter-Tie Resource supplied within the bid |
| min_hourly_block_limit |
The registered upper bound of minimum hourly block for an Inter-Tie Resource |
| min_idc |
The minimum direct current (Id) on the DC side at which the converter should ... |
| min_initial_sym_sh_ccurrent |
Minimum initial symmetrical short-circuit currents (Ik" min) in A (Ik" = Sk"/... |
| min_limit |
Minimum Limit (MW) |
|
|
| min_load |
Minimum MW load below which it may not be reduced |
| min_load_cost |
minimum load cost |
| min_load_reduction |
Minimum MW for a load reduction (e |
| min_load_reduction_cost |
Cost in $ at the minimum reduced load |
|
|
| min_load_reduction_interval |
Shortest period load reduction shall be maintained before load can be restore... |
| min_mw |
Minimum MW limit (only for transmission constraints) |
| min_off_time |
Minimum off time after shut down |
| min_on_time |
Minimum on time after start up |
| min_operating_p |
This is the minimum operating active power limit the dispatcher can enter for... |
| min_p |
Minimum active power of the injection |
| min_q |
Minimum reactive power limit for the unit |
| min_r_to_x_ratio |
Minimum ratio of positive sequence resistance of Network Feeder to its positi... |
| min_reduction_time |
Minimum Load Reduction Time (min), per Participating Load Resource |
| min_self_sched_mw |
Minimum amount of self schedule MW allowed for an embedded control area |
| min_status_change_time |
Minimum start up time required to bring the unit online (minutes) |
| min_sufficiency_index |
Region requirement minimum limit |
|
|
| min_time_bet_load_red |
Shortest time that load shall be left at normal levels before a new load redu... |
| min_u |
Minimum voltage limit for the unit |
| min_udc |
The minimum voltage on the DC side at which the converter should operate |
| min_value |
Normal value range minimum for any of the MeasurementValue |
| min_yvalue |
The minimum value of the DERMonitorableParameter during the time interval |
| min_z_to_z_ratio |
Minimum ratio of zero sequence impedance to its positive sequence impedance (... |
| minerr |
Minimum value for speed error signal (minerr) (< GovCT1 |
| minimal_usage_expected |
If true, minimal or zero usage is expected at this usage point for situations... |
| minimum_activation_quantity |
The minimum quantity of energy that can be activated at a given time interval |
| minimum_active_power |
The minimum active power flow |
| minimum_angle |
The minimum phase angle shift of the phase shifter |
|
|
| minimum_capacity |
minimum capacity |
| minimum_current |
The lowest value of current that the switch can make, carry and break in unin... |
| minimum_down_time |
The minimum number of hours the unit must be down before restart |
| minimum_economic_mw |
Low economic MW limit that shall be greater than or equal to the minimum oper... |
| minimum_level |
Minimum MW value of contract |
|
|
| minimum_load |
Minimum Load |
|
|
| minimum_load_cost |
Total Minimum Load Cost ($) over the time horizon |
|
|
| minimum_load_cost_basis |
The cost basis for minimum load |
| minimum_load_fuel_cost |
The cost for the fuel required to get a Generating Resource to operate at the... |
| minimum_mw |
The minimum active power generation of the unit in MW |
|
|
| minimum_off_time |
Minimum time interval between unit shutdown and startup |
| minimum_operating_limit |
This is the minimum operating MW limit the dispatcher can enter for this unit |
| minimum_reactive_power |
The minimum reactive power flow |
| minimum_run_time |
The minimum number of hours the unit must be operating before being allowed t... |
| minimum_schedule_quantity |
Minimum schedule quanity |
|
|
| minimum_update_interval |
Specifies the fastest update interval that can be provided for integrity info... |
| minor |
minor release level for this version |
| minor_version |
Describe minor updates and error corrections |
| misc_cost_items |
|
| mitigated_bid |
|
| mitigated_bid_clearing |
|
| mitigated_bid_segment |
|
| mitigation_occured_flag |
|
| mitigation_status |
Mitigation Status: |
|
|
| mkt_acline_segment_end_aflow |
|
| mkt_acline_segment_end_bflow |
|
| mkt_activity_record |
|
| mkt_combined_cycle_plant |
|
| mkt_connectivity_node |
|
| mkt_contingency |
|
| mkt_contingency_a |
|
| mkt_contingency_b |
|
| mkt_control_area |
|
| mkt_flow |
The amount of energy flow over a specifed flowgate due to generation in the m... |
| mkt_generating_unit |
|
| mkt_heat_rate_curve |
|
| mkt_line |
|
| mkt_measurement |
Allows Measurements to be associated to Pnodes |
| mkt_power_transformer |
|
| mkt_power_transformer_end_aflow |
|
| mkt_power_transformer_end_bflow |
|
| mkt_psrtype |
|
| mkt_scheduled_event |
|
| mkt_series_compensator_end_bflow |
|
| mkt_serires_compensator_end_aflow |
|
| mkt_shunt_compensator |
|
| mkt_switch |
|
| mkt_tap_changer |
|
| mkt_terminal |
|
| mkt_thermal_generating_unit |
|
| mkt_user_attribute |
|
| mnef |
Fuel flow maximum negative error value (MNef) |
| mobile_phone |
Mobile phone number |
| mode |
The regulating control mode presently available |
| model |
Modle parts conforming to the model part specification |
| model_detail |
Detail level of the generator model data |
| model_frame |
Model frames of the model frame type |
| model_frame_type |
Model frame type of the model frame |
| model_number |
Manufacturer's model number |
| model_operation |
The opeation for the operation argument |
| model_operation_arg |
Arguments of the operation |
| model_operation_definition |
The type of operation for this type of dataset role |
| model_operation_description |
The type of the model operation |
| model_part_version |
|
| model_specification |
Model specification of the modelt |
| model_type |
Type of synchronous machine model used in dynamic simulation applications |
| model_version |
Version number for product model, which indicates vintage of the product |
| modeling_authority |
Modeling Authority suppliying and maintaining the data for the objects in thi... |
| modeling_authority_sets |
Modeling Authority Sets supplied and maintained by this Modeling Authority |
| modified_by |
Source/initiator of modification |
| modified_date |
Last time and date clearing results were manually modified |
| mom_failure_rate |
Momentary failure rate (temporary failures/kft-year) |
| monetary_unit |
Unit of currency |
| monitor_active_power |
Monitor the active power flow |
| monitor_reactive_power |
Monitor the reactive power flow |
| monitored_phase |
Phase voltage controlling this regulator, measured at regulator location |
| most_recent_fault_operation_date |
Date of most recent breaker fault operation |
| most_recent_motor_start_date |
Date of most recent motor start |
| most_recent_operation_date |
Date of most recent breaker operation (fault or non-fault) |
| motor_run_current |
Rated motor run current in amps |
| motor_start_current |
Rated motor start current in amps |
| motor_voltage |
Nominal motor voltage in volts DC |
| moving_contact |
Moving contact of interrupter to which this bushing is attached |
| mpmclearing |
|
| mpmresource_status |
|
| mpmtest_category |
|
| mpmtest_results |
|
| mpmtest_threshold |
|
| mpuvrt |
Enable UVRT power control mode (MpUVRT) |
| mqpri |
Prioritisation of Q control during UVRT (Mqpri) |
| msg_level |
|
| mss_instruction_id |
Unique instruction id per instruction, assigned by the SC and provided to ADS |
| mssaggregation |
|
| msszone |
|
| mu |
Factor to calculate the breaking current (Section 4 |
| multiple_premises |
Set to true if the outage report indicated that other neighbors are also out ... |
| multiplicity_maximum |
|
|
|
| multiplicity_minimum |
|
|
|
| multiplier |
|
| multiply_before_add |
Whether scalars should be applied before adding the 'offset' |
| must_be_deenergised |
If true, the equipment must be deenergised |
| must_be_grounded |
If true, the equipment must be grounded |
| must_offer_flag |
Must offer flag: indicates whether the unit is subject to the must offer prov... |
| must_offer_ra |
Flag to indicate that this unit is a resource adequacy resource and must offe... |
| must_run_ind |
Identifes if the unit was set to must run by the market participant responsib... |
| must_study |
Set true if must study this contingency |
| mw |
Unit active power generation in MW |
|
|
| mw_dop |
Dispatched Operating Point (MW) |
|
|
| mw_flow |
The MW flow on the branch |
|
|
| mw_limit |
Binding MW limit |
| mwbase |
Base for power values (MWbase) (> 0) |
| mwlimit_schedules |
|
| mwtcwp |
Crowbar control mode (MWTcwp) |
| mxef |
Fuel flow maximum positive error value (MXef) |
| mzc |
Zero crossing measurement mode (Mzc) |
| n |
Order of ramp tracking filter (N) |
| name_of_local_icc |
Specifies the ICC scope name that the remote can use to access the informatio... |
| name_type |
Type of this name |
| name_type_authority |
Authority responsible for managing names of this type |
| name_types |
All name types managed by this authority |
| nameplate_capacity |
MW value stated on the nameplate of the Generator -- the value it potentially... |
| names |
All names of this identified object |
| naming_feeder |
The primary feeder that normally energizes the secondary substation |
| naming_secondary_substation |
The secondary substations that are normally energized from the feeder |
| native |
Native |
| nav |
Number of control outputs to average (NAV) (1 <= NAV <= ... |
| ncl |
Number of counts at limit to active limit function (NCL) (> 0) |
| ncr |
Number of counts until reset after limit function is triggered (NCR) |
| nearest_intersection |
The names of streets at the nearest intersection to work area |
| needs_inspection |
True if inspection is needed of facilities at this service location |
| needs_power_limit_check |
True if load limit has to be checked to issue an immediate disconnect (after ... |
| needs_voltage_limit_check |
True if voltage limit has to be checked to prevent connect if voltage is over... |
| negate |
Invert/negate the result of the compare |
| negative_polarity |
The polarity of the strike, with T meaning negative |
| negative_r |
Negative sequence series resistance from terminal sequence 2 to terminal sequ... |
| negative_x |
Negative sequence series reactance from terminal sequence 2 to terminal seque... |
| net_amount |
Net line item charge amount |
| net_firm_network_limit |
Net Energy flow in flowgate for the associated FlowgatePartner |
|
|
| net_interchange |
The specified positive net interchange into the control area, i |
| net_isoamount |
Net ISO settlement amount |
| net_isoquantity |
Net ISO settlement quantity |
| net_price |
Net settlement price |
| net_quantity |
Net settlement quantity, subject to the UOM |
| network_analysis_enabled |
The equipment is enabled to participate in network analysis |
| network_asset_deployment |
A network asset deployment at this base voltage level |
| network_boundary |
|
| network_frame |
|
| network_model_case_definition |
|
| network_model_project_change |
The persistent network model project change to which this version applies |
| network_model_project_change_version |
The project of the details of model changes |
| network_model_project_component |
|
| network_model_project_document |
|
| network_model_project_state |
The state of this network model project version |
| neutral_bil |
Basic insulation level of neutral |
| neutral_step |
The neutral tap step position for this winding |
| neutral_strand_count |
Number of concentric neutral strands |
| neutral_strand_gmr |
Geometric mean radius of the neutral strand |
| neutral_strand_radius |
Outside radius of the neutral strand |
| neutral_strand_rdc |
DC resistance per unit length of the neutral strand at 20 °C |
| neutral_u |
Voltage at which the winding operates at the neutral tap setting |
| nmproject_stage |
|
| no_load_cost |
Resource fixed no load cost |
| no_load_cost_eligibility_flag |
|
| node_constraint_term |
|
| nom_u |
The voltage at which the nominal reactive power may be calculated |
| nominal_discharge_current |
The lightning discharge current used to classify the arrester |
| nominal_frequency |
Nameplate data indicates if the machine is 50 Hz or 60 Hz |
| nominal_p |
The nominal power of the generating unit |
| nominal_ratio |
Nominal ratio between the primary and secondary voltage |
| nominal_service_voltage |
Nominal service voltage |
| nominal_speed |
Nameplate data |
| nominal_temperature |
Maximum nominal design operating temperature |
| nominal_u |
The nominal voltage for which the coil is designed |
| nominal_voltage |
The power system resource's base voltage |
| nominal_yvalue |
The nominal value of the DERMonitorableParameter during the time interval |
| non_conform_load_group |
The NonConformLoadGroup where the NonConformLoadSchedule belongs |
| non_conform_load_schedules |
The NonConformLoadSchedules in the NonConformLoadGroup |
| non_market |
Flag to indicate that the Resource is not participating in the Market Operati... |
| non_ramp_restricted_mw |
Desired MW that is not ramp restricted |
| non_spin_reserve |
Non Spin Reserve used to procure energy |
| nonlinear_shunt_compensator |
Non-linear shunt compensator owning this point |
| nonlinear_shunt_compensator_phase |
Non-linear shunt compensator phase owning this point |
| nonlinear_shunt_compensator_phase_points |
All points of the non-linear shunt compensator phase |
| nonlinear_shunt_compensator_points |
All points of the non-linear shunt compensator |
| normal_armed |
The default/normal value used when other active signal/values are missing |
| normal_enabled |
The default/normal value used when other active signal/values are missing |
| normal_energized_feeder |
The normal energized feeders of the substation |
| normal_energized_substation |
The substations that are normally energized by the feeder |
| normal_energizing_feeder |
The feeders that potentially energize the downstream substation |
| normal_energizing_substation |
The substation that nominally energizes the feeder |
| normal_head_feeder |
The feeder that this terminal normally feeds |
| normal_head_terminal |
The normal head terminal or terminals of the feeder |
| normal_high_volt_limit |
Normal high voltage limit |
| normal_low_volt_limit |
Normal low voltage limit |
| normal_min_operate_level |
Normal minimum operating level below which the penstocks will draw air |
| normal_open |
The attribute is used in cases when no Measurement for the status value is pr... |
| normal_pf |
Generating unit economic participation factor |
| normal_rating |
The Normal Rating for the branch |
|
|
| normal_sections |
For the capacitor phase, the normal number of sections switched in |
| normal_step |
The tap step position used in "normal" network operation for this winding |
| normal_value |
Normal measurement value, e |
| normally_in_service |
Specifies the availability of the equipment under normal operating conditions |
| not_ready_for_use_date |
Date of most recent asset transition to not ready for use state |
| not_yet_installed_date |
Date and time of asset deployment transition to not yet installed |
| note |
Free format note relevant to this line |
| notification |
Notification for this trouble ticket |
| notification_time |
Time required for crew notification prior to start up of the unit |
| notification_time_curve |
|
| nq |
Deadband of reactive power (nq) |
| number |
Designator of the specific location on the street |
| number_interval |
Number of intervals of bill determiant in trade day, e |
| number_of_intervals |
Used to specify the number of intervals when requesting a forecast or a dispa... |
| number_of_startups |
Number of start ups in the Operating Day until the end of previous hour |
| number_of_valves |
Number of valves in the converter |
| numerator |
Numerator |
| nvphz |
Pickup speed of V/Hz limiter (Nvphz) |
| o_mcost |
Operating and maintenance cost for the thermal unit |
| object_aggregation |
Identification of the object that is the common denominator used to aggregate... |
| object_modification |
The associated data object representing the update |
| object_reverse_modification |
The data object holding preconditions of updates |
| occurred_date_time |
The date and time at which the dispatch status occurred |
| odometer_read_date_time |
Date and time the last odometer reading was recorded |
| odometer_reading |
Odometer reading of this vehicle as of the 'odometerReadingDateTime' |
| oelin |
OEL input (OELin) |
| off_peak |
Indication that this distribution factor is to apply during off peak |
| offset |
The offset from midnight (i |
| offset_current |
The offset current that the Petersen coil controller is operating from the re... |
| offset_x |
The offset in the X direction |
| offset_y |
The offset in the Y direction |
| oil_color |
Oil Quality Analysis-Color |
| oil_dielectric_strength |
Oil Quality Analysis-Dielectric Strength |
| oil_ift |
Oil Quality Analysis- inter facial tension (IFT) - number-Dynes/CM |
| oil_level |
The level of oil in the transformer |
| oil_neutralization_number |
Oil Quality Analysis-Neutralization Number - Number - Mg KOH |
| oil_percent_above_low_sustained_limit |
Percentage of Fuel Oil Price (FOP) for operating above Low Sustained Limit (L... |
| oil_percent_cold_startup |
Percentage of Fuel Oil Price (FOP) for cold startup |
|
|
| oil_percent_hot_startup |
Percentage of Fuel Oil Price (FOP) for hot startup |
|
|
| oil_percent_intermediate_startup |
Percentage of Fuel Oil Price (FOP) for intermediate startup |
|
|
| oil_percent_low_sustained_limit |
Percentage of FOP (oil) for operating at LSL |
|
|
| oil_preservation_kind |
Kind of oil preservation system |
| oil_price |
|
| oil_price_index |
The average oil price at a defined fuel region |
| oil_sample_taken_from |
Location from which oil sample taken |
| oil_sample_temperature |
Oil sample temperature |
| oil_temperature_source |
Source of oil temperature |
| oil_volume_per_tank |
Volume of oil in each tank of bulk oil breaker |
| old_asset |
Old asset replaced by this work task |
| old_data |
Measurement value is old and possibly invalid, as it has not been successfull... |
| old_meter |
Old meter replaced by this work task |
| om_cost_cold_startup |
Verifiable O&M Cost ($), Cold Startup |
|
|
| om_cost_hot_startup |
Verifiable O&M Cost ($), Hot Startup |
|
|
| om_cost_intermediate_startup |
Verifiable O&M Cost ($), Intermediate Startup |
|
|
| om_cost_low_sustained_limit |
Verifiable O&M Cost ($/MWh), LSL |
|
|
| omegadtd |
Active drive train damping frequency (omegaDTD) |
| omeganh |
Notch filter 2 (high-frequency band): filter frequency (omegan... |
| omeganl |
Notch filter 2 (low-frequency band): filter frequency (omegani... |
| omegaoffset |
Offset to reference value that limits controller action during rotor speed ch... |
| omegazero |
Rotor speed if the wind turbine is not derated (omega0</... |
| on_peak |
Indication that this factor is to apply during Peak periods |
| on_request_read |
True if on request read function is supported |
| one_call_request |
|
| online_status |
'true' if the GeneratingUnit is currently On-Line |
|
|
| op_reserve_reqt |
Operating reserve requirement in MW, where operating reserve is the generatin... |
| open |
The attribute tells if the switch is considered open when used as input to to... |
| open_end |
Transformer end measured for induced voltage and angle in this open-circuit t... |
| open_end_open_circuit_tests |
All open-circuit test measurements in which this transformer end was not exci... |
| open_end_step |
Tap step number for the open end of the test pair |
| open_end_voltage |
Voltage measured at the open-circuited end, with the energised end set to rat... |
| operated_by_protection_equipment |
Protection equipments that operate this ProtectedSwitch |
| operated_switch |
Switch that is the object of this switch action |
| operating_date |
Operating date, hour |
| operating_limit_high |
The upper operating limit incorporating any derate used by the RTD for the Bi... |
| operating_limit_low |
The lower operating limit incorporating any derate used by the RTD for the Bi... |
| operating_maintenance_cost |
The portion of the Operating Cost of a Generating Resource that is not relate... |
| operating_mechanism |
Breaker mechanism controlling this interrupter |
| operating_mode |
Bid operating mode ('C' - cycling, 'F' - fixed, 'M' - must run, 'U' - unavail... |
| operating_participant |
The operating participant having this share with the associated power system ... |
| operating_share |
The operating shares of this power system resource |
| operation |
|
| operation_dataset_arg |
The operation dataset roles conforming to this role type |
| operation_dataset_arg_description |
The type of dataset roles that can be used for a type of general model operat... |
| operation_in_progress |
Indicates that a client is currently sending control commands that has not co... |
| operation_mode |
The operating mode of an HVDC bipole (bipolar, monopolar metallic return, etc... |
| operation_sequence |
|
| operational_limit |
The operational limits to which this limit dependency model applies |
| operational_limit_set |
The operational limit sets at the terminal |
| operational_limit_type |
The limit type associated with this limit |
| operational_limit_value |
Values of equipment limits |
| operational_restrictions |
All operational restrictions for this equipment |
| operational_tag |
Tag associated with this tag action |
| operational_tags |
All operational tags placed on this power system resource |
| operational_transmission_capacity |
The Operational Transmission Capacity (OTC) is the transmission capacity unde... |
| operational_values_considered |
It is used to define if the data (other attributes related to short circuit d... |
| operator |
Operator responsible for this switching step |
| operator_blocked |
Measurement value is blocked and hence unavailable for transmission |
| optimal_bid_cost |
Optimal Bid cost |
|
|
| optimal_bid_pay |
Optimal Bid production payment based on LMP |
|
|
| optimal_margin |
Optimal Bid production margin |
|
|
| optimization_flag |
Included in optimization Y/N |
| optimized |
Fixed (covers re-configuration, grandfathering) or Optimized (up for sale/pur... |
| order |
Order of the statistical calculation method within the calculation method hie... |
| org_pnode_allocation |
|
| org_res_ownership |
|
| organisation |
Organisation having this role |
| organisation_roles |
All roles an organisation plays for this asset |
| orientation |
Coordinate system orientation of the diagram |
| original_customers_served |
the total number of customers that are served in the area (both outaged and n... |
| original_meters_affected |
The original number of meters that were affected as reported by the OMS withi... |
| oscillatory |
To prevent some overload of the communication it is sensible to detect and su... |
| osi_psel |
Is the addressing selector for OSI presentation addressing |
| osi_ssel |
Is the OSI session layer addressing information |
| osi_tsel |
Is the OSI Transport Layer addressing information |
| otc__min_emergency |
The Operational Transmission Capacity (OTC) 15 minute Emergency Limit |
|
|
| otcemergency |
The Operational Transmission Capacity (OTC) Emergency Limit |
| out_balance |
Outstanding balance on the CustomerAccount as of the statement date |
| out_of_market_type |
To indicate an out-of-market (OOM) schedule |
| out_of_range |
Measurement value is beyond a predefined range of value |
| out_of_service_date |
Date and time asset most recently taken out of service |
| outage |
Outage for this incident |
| outage_area |
The outage area where the outage occured |
| outage_area_kind |
defines the type of area that has the outage - county, state, zipcode, etc |
| outage_date_time_interval |
The window of time during which one or more customers will be de-energized du... |
| outage_history |
True if outage history function is supported |
| outage_isolation_equipment |
The equipment that isolates this outage |
| outage_kind |
Defines if the outage has been verified or is only estimated |
| outage_order |
The outage order at this location |
| outage_plan |
The outage plan that identifies the customers that are affected |
| outage_region |
Outage region in which this usage point is located |
| outages |
All outages in which this equipment is involved |
| outcome |
The results of the test |
| outer_jacket_kind |
Kind of outer jacket of this cable |
| output |
Output value (y) for the lookup table function |
| over_flow |
Measurement value is beyond the capability of being represented properly |
| overall_length |
Overall length of this asset model |
| overexcitation_limiter_dynamics |
Overexcitation limiter model associated with this excitation system model |
| overexcitation_limiter_user_defined |
Proprietary user-defined model with which this parameter is associated |
| overhead_cost |
|
| overload_mw |
Transmission overload MW |
| override_time_stamp |
Time the manual data entry occured |
| override_value |
Provides the ability for the grid operator to override items, such as spin ca... |
| ovex |
Overexcitation Flag (OVEX) |
|
|
| owner |
Operator who owns this incident |
| ownership_percent |
ownership percentage for each resource |
|
|
| ownerships |
All ownerships of this asset |
| p |
|
| p_constant_current |
Portion of active power load modelled as constant current |
| p_constant_impedance |
Portion of active power load modelled as constant impedance |
| p_constant_power |
Portion of active power load modelled as constant power |
| p_dist_factor |
Real power (MW) load distribution factor |
|
|
| p_frequency_exponent |
Exponent of per unit frequency effecting active power |
| p_injection |
The active power injected into the bus at this location in addition to inject... |
| p_max |
This is the maximum active power that can be produced by the source |
| p_min |
This is the minimum active power that can be produced by the source |
| p_pcc_control |
Kind of control of real power and/or DC voltage |
| p_tolerance |
Active power net interchange tolerance |
| p_voltage_exponent |
Exponent of per unit voltage effecting real power |
| paid_to |
The company to which the PTB transaction is paid |
| pan |
The primary account number |
| pan_pricing |
PAN pricing command/action issuing this price detail |
| pan_pricing_details |
All pricing details issued by this PAN pricing command/action |
| parallel_path_flag |
Flag which indicates if the transmission path is also a designated interconne... |
| parameter_number |
Sequence number of the parameter among the set of parameters associated with ... |
| parent |
|
| parent_charge |
Parent of this charge sub-component |
| parent_cost_type |
|
| parent_cugroups |
|
| parent_of_a |
A ControlAreaOperator has a collection of tie points that ring the ControlAre... |
| parent_of_b |
A CustomerConsumer may ring its perimeter with metering, which can create a u... |
| parent_organisation |
Parent organisation of this organisation |
| parent_project |
|
| participation_category |
Designated Control Area participation in LMP price measurement |
|
|
| participation_factor_set |
Participation Factor flag |
|
|
| particle_size |
The diameter of the particles during the time interval |
| pass_indicator |
Part of the Composite key that downstream app uses to match the instruction |
| pass_through_bill |
|
| pass_trough_bill |
|
| password |
Password needed to log in |
| pavail |
Available aerodynamic power (pavail) |
| pay_amount |
Amount to be paid by the service provider to the customer for each violation ... |
| pay_congestion |
Willing to Pay congestion flag |
|
|
| pay_cycle |
The contractually expected payment frequency (by the customer) |
| payment |
Total cost of permit |
| payment_terms |
The terms which dictate the determination of the bid payment price |
| payment_transactions |
All payment transactions for this customer account |
| pbf |
Power controller flag (Pbf) |
| pcc_terminal |
Point of common coupling terminal for this converter DC side |
| pcontrol |
|
| pdtdmax |
Maximum active drive train damping power (pDTDmax) |
| peak_amplitude |
Peak current of strike |
| peak_flag |
on-peak, off-peak, or all |
| peflag |
Electric power input selection (Peflag) |
| penalty_dispatch_indicator |
Penalty Dispatch Indicator (Yes / No) indicating an un-economic adjustment |
| penalty_factor |
Defined as: 1 / ( 1 - Incremental Transmission Loss); with the Incremental Tr... |
| pending_calculation |
Pending calculation that produced this reading type |
| penstock_loss_curve |
A hydro generating unit has a penstock loss curve |
| penstock_type |
Type and configuration of hydro plant penstock(s) |
| per_length_impedance |
Per-length impedance of this line segment |
| per_length_line_parameter |
Per length line parameter associated with this wire assembly |
| per_length_parameter |
Set of per-length parameters for this line segment |
| percent |
Price Threshold in % |
|
|
| percent_complete |
Estimated percentage of completion of this individual work task or overall wo... |
| percent_mw |
Actual MW flow as percent of limit |
| percentage |
Percentage operational ownership between the pair (power system resource and ... |
| performance_factor |
Capability performance factor |
| period |
|
| permit_id |
Permit identifier |
| person |
Person having this role |
| persons |
All persons for this appointment |
| pfixed |
Active power of the load that is a fixed quantity |
| pfixed_pct |
Fixed active power as per cent of load group fixed active power |
| pfmode |
|
| pfmodel |
|
| pfrac |
Fraction of constant-power load to be represented by this motor model (P</... |
| pfref |
Power factor reference (PFREF) |
| pfvar_controller_type_dynamics |
Power factor or VAr controller type 2 model associated with this excitation s... |
| pfvar_controller_type_user_defined |
Proprietary user-defined model with which this parameter is associated |
| pgv |
Nonlinear gain point 6, PU power (Pgv6) |
| phase |
The terminal phase at which the connection is applied |
| phase_angle_clock |
Winding phase angle where 360 degrees are represented with clock hours, so th... |
| phase_code |
Phase code |
| phase_connection |
The type of phase connection, such as wye or delta |
| phase_count |
Number of potential phases the Usage Point supports, typically 0, 1 or 3 |
| phase_impedance |
Conductor phase impedance to which this data belongs |
| phase_impedance_data |
All data that belong to this conductor phase impedance |
| phase_info |
Phase information |
| phase_shift |
Phase shift measured at the open end with the energised end set to rated volt... |
| phase_side |
Phase of this SwitchPhase on the side with terminal sequence number equal to ... |
| phase_tap_changer |
Phase tap changer associated with this transformer end |
| phase_tap_changer_table |
The table of this point |
| phase_tap_changer_table_point |
The points of this table |
| phase_tap_changer_tabular |
The phase tap changers to which this phase tap table applies |
| phase_trip |
Phase trip rating |
| phase_trip_rating |
Phase trip rating |
| phase_wire_count |
Number of wire sub-conductors in the symmetrical bundle (typically between 1 ... |
| phase_wire_spacing |
Distance between wire sub-conductors in a symmetrical bundle |
| phases |
Represents the normal network phasing condition |
| phenomenon_classification |
Phenomenon classification to which this condition relates |
| phone |
Additional phone number |
| physical_connection_capacity |
Quantitative information about the maximum physical capacity of the connectio... |
| physical_rights_dam |
Flag to indicate this contract provides physical rights in the DA Market |
| physical_rights_rtm |
Flag to indicate this contract provides physical rights in the RT Market |
| pick_up_ramp_rate |
Maximum rate load may be restored (MW/minute) |
|
|
| pid_max |
Controller follow up gain (PID1max) |
| pidlim |
PID limiter indicator |
| pin_branch_group |
|
| pin_equipment |
|
| pin_gate |
|
| pin_measurement |
|
| pin_terminal |
|
| planned_commissioned_date |
|
| planned_date_time |
Planned date and time of this switching step |
| planned_execution_interval |
The planned start and end time for the switching order |
| planned_market |
A planned market could have multiple market runs for the reason that a planne... |
| planned_market_event |
Planned event executed by this actual event |
| planned_outage |
The planned outage that has the field dispatch history |
| planned_outage_notification |
The notification of the planned outage |
| planned_period |
the planned start and end times for the switching plan |
| planned_switch_actions |
All switch actions to apply within the scope of this planned outage |
| planned_time |
This is relative time so that this attribute can be used by more than one pla... |
| plant_discharge_capacity |
Total plant discharge capacity |
| plant_rated_head |
The plant's rated gross head |
| plant_transfer_date_time |
Date and time asset's financial value was put in plant for regulatory account... |
| plim |
Power Limit 9 (Plim9) |
| plot_priority |
A value used to establish priority of the DOP when plotting |
| pmax |
Gate maximum (Pmax) (> GovHydroIEEE0 |
| pmaxhp |
Maximum HP value position (Pmaxhp) |
| pmaxlp |
Maximum LP value position (Pmaxlp) |
| pmin |
Gate minimum (Pmin) (< GovHydroIEEE |
| pmss |
Pmss flow P9 (Pmss9) |
| pmwset |
Power controller setpoint (Pmwset) (see parameter detail 1) |
| pnode |
A registered resource injects power at one or more connectivity nodes related... |
| pnode_clearing |
|
| pnode_distribution_factor |
|
| pnode_results |
|
| pnodes |
|
| po_box |
Post office box |
| pod |
point of delivery |
|
|
| pod_loss_factor |
Point of delivery loss factor |
|
|
| podtransmission_path |
A transmission path has a "point-of-delivery" service point |
| point |
|
| point_of_delivery_flag |
Indication that the registered resource is a Point of Delivery (YES) resource... |
| point_of_receipt |
A transmission path has a "point-of-receipt" service point |
| point_of_sale |
Point of sale that is in operation during this shift |
| point_quality |
Specifies the type of ICCP quality that will be conveyed as part of the ICCP ... |
| point_type |
Indicates the ICCP Point type that is to be conveyed |
| polarity |
Represents the normal network polarity condition |
| pole |
Pole to which thiss streetlight is attached |
| pole_count |
Number of poles (i |
| pole_loss_p |
The active power loss at a DC Pole |
|
|
| pole_pair_number |
Number of pole pairs of stator |
| por |
point of receipt |
|
|
| port |
This value is only needed to be specified for called nodes (e |
| portransmission_path |
A transmission path has a "point-of-receipt" service point |
| position |
Position of asset or asset component |
| position_current |
The control current used to control the Petersen coil also known as the posit... |
| position_points |
Sequence of position points describing this location, expressed in coordinate... |
| positive_flow_in |
Specifies the sign of the tie flow associated with a control area |
| positive_r |
Positive sequence series resistance from terminal sequence 2 to terminal sequ... |
| positive_x |
Positive sequence series reactance from terminal sequence 2 to terminal seque... |
| post_transfer_mw |
Post Transfer MW for step |
|
|
| postal_address |
Postal address, potentially different than 'streetAddress' (e |
| postal_code |
Postal code for the address |
| posted |
If true, merchantDebitAmount has been debited from MerchantAccount; typically... |
| posted_date |
Bid clearing results posted time and date |
| posted_date_time |
Date and time this entry was posted to the ledger |
| posting_date_time |
Date and time this entry is to be posted to the ledger |
| power |
Short circuit apparent power |
| power_cut_zone |
The energy consumer is assigned to this power cut zone |
| power_direction_flag |
Direction same as positive active power flow value |
| power_electronics_connection |
The power electronics connection associated with this wind turbine type 3 or ... |
| power_electronics_connection_phase |
The individual phases models for the power electronics connection |
| power_electronics_unit |
An AC network connection may have several power electronics units connecting ... |
| power_factor_min |
Threshold minimum power factor for this PricingStructure, specified in instan... |
| power_limit |
Load limit above which the connect should either not take place or should cau... |
| power_rating |
The power rating associated with type of cooling specified for this stage |
| power_ratings |
|
| power_system_resource |
Power system resources which belong to this reporting group |
| power_system_resources |
All power system resources with this datasheet information |
| power_system_stabilizer_dynamics |
Power system stabilizer model associated with this excitation system model |
| power_system_stabilizer_user_defined |
Proprietary user-defined model with which this parameter is associated |
| power_transformer |
Bank this transformer belongs to |
| power_transformer_end |
The ends of this power transformer |
| power_transformer_info |
Power transformer data that this tank description is part of |
| power_variation_by_temp |
Per unit change in power per (versus) unit change in ambient temperature |
| ppss |
Coefficient (p_PSS) (>= 0 and <= 4) |
| pr |
Second value of pressure set point static characteristic, corresponding to <i... |
| prate |
Ramp rate for frequency-dependent power limit (Prate) |
| precedence |
An indicator of the order a resource should be substituted |
| precision |
Precision of related analog value if different from precision of test standar... |
| precision_level |
The level of precision in the current value |
| prediction_creation_date |
The timestamp for when the DER Group forecast was created |
| prefix |
A prefix or title for the person's name, such as Miss, Mister, Doctor, etc |
| prefmax |
Maximum pWTref request from the plant controller to ... |
| prefmin |
Minimum pWTref request from the plant controller to ... |
| preliminary_code |
Code for problem type determined during preliminary assessment |
| preliminary_date_time |
Date and time preliminary assessment of problem was performed |
| preliminary_remark |
Remarks pertaining to preliminary assessment of problem |
| preservative_kind |
Kind of preservative for this pole |
| pressure_cg |
Pressure control gain |
| pressure_compensation |
True if device performs pressure compensation for metered quantities |
| pressure_ctrl_dg |
Pressure control derivative gain ratio |
| pressure_ctrl_ig |
Pressure control integral gain ratio |
| pressure_ctrl_pg |
Pressure control proportional gain ratio |
| pressure_feedback |
Pressure feedback indicator |
| pressure_limit |
Pressure limit |
| pressure_relief_class |
Fault current level at which all parts of the failed arrester lie within a ci... |
| pressure_setpoint_ga |
Pressure setpoint gain adjuster |
| pressure_setpoint_tc |
Pressure setpoint time constant |
| previous_amount |
Previous line item charge amount |
| previous_dottime_stamp |
Timestamp when the previous DOT value was issued |
| previous_end |
The previous bill period end date |
|
|
| previous_isoamount |
Previous ISO settlement amount |
| previous_isoquantity |
Previous ISO settlement quantity |
| previous_price |
Previous settlement price |
| previous_quantity |
Previous settlement quantity, subject to the UOM |
| previous_start |
The previous bill period start date |
|
|
| prhmax |
Maximum low pressure limit (Prhmax) |
| price |
Price to customer for implementing design |
| price_descriptor |
|
| price_ratio |
Ratio of 'price' to the "normal" price chosen by the commodity provider |
| price_set_flag_da |
Price setting flag: indicates whether a resource is capable of setting the Ma... |
| price_set_flag_rt |
Price setting flag: indicates whether a resource is capable of setting the Ma... |
| price_setting |
Flag to indicate that the facility can set LMP Works in tandem with Metered V... |
| price_signal |
(if applicable) Price signal used as parameter for this end device control |
| price_tier |
Pricing tier as chosen by the commodity provider |
| price_tier_count |
Maximum number of price tiers available |
| price_tier_label |
Label for price tier |
| price_type |
The "kind" of price being described |
| pricing_info |
True if pricing information is supported |
| pricing_structure |
Pricing structure applicable for this transaction |
| pricing_structures |
All pricing structures applicable to this service delivery point (with prepay... |
| primary |
primary configuration |
| primary_configuration |
Whether this CombinedCycleConfiguration is the primary configuration in the a... |
| primary_device_timing |
Timing for the control actions performed on the device identified in the end ... |
| primary_fls_rating |
Full load secondary (FLS) rating for primary winding |
| primary_ratio |
Ratio for the primary winding tap changer |
| primary_reserve_reqt |
Primary reserve requirement in MW, where primary reserve is generating capabi... |
| primary_yn |
|
| prime_mover_rating |
Rating of prime mover |
| prime_movers |
Prime movers that drive this SynchronousMachine |
| principle |
Part of 'current' that constitutes the portion of the principle amount curren... |
| principle_amount |
The initial principle amount, with which this account was instantiated |
| priority |
Priority of bus name marker for use as topology bus name |
| priority_flag |
This is a Y/N flag for a self-schedule of a resource per market per date and ... |
| prmax |
Max |
| pro_forma |
True if payment is to be paid by a Customer to accept a particular ErpQuote (... |
| probability_percent |
Probability of weather condition occurring during the time interval expressed... |
| procedure |
Procedure capturing this data set |
| procedure_data_set |
Procedure data set that applies to this asset |
| procedure_data_sets |
|
| procedures |
All procedures applicable to this asset |
| process |
|
| process_type |
The kind of business process |
| product |
The type of the product such as Power, energy, reactive power, transport capa... |
| product_asset_model |
Product asset model which conforms to this catalog asset type |
| product_asset_models |
All asset models by this manufacturer |
| product_bid |
|
| product_bids |
|
| product_code |
The product identifier for determining the charge type of the transaction |
| profile |
The profiles that describe the contents of the data set and the rules governi... |
| profile_datas |
A profile has profile data associated with it |
| program_id |
Name of program |
| project |
|
| project_a |
|
| project_arelationships |
|
| project_b |
|
| project_brelationships |
|
| projects |
|
| properties |
UserAttributes used to specify further properties of this procedure data set |
| properties_cimdata_object |
The single CIM data object in the appropriate dataset context |
| properties_object |
The CIM object holding the properties of this dataset context |
| property_account |
Used for property record accounting |
| property_data |
Property related information that describes the ROW's land parcel |
| property_name |
|
| property_specification |
|
| property_unit |
|
| property_units |
|
| property_value |
|
| proportional_gain |
Proportional gain |
| proprietary |
Behaviour is based on a proprietary model as opposed to a detailed model |
| proprietary_parameter_dynamics |
Parameter of this proprietary user-defined model |
| protected_switch |
A breaker may have zero or more automatic reclosures after a trip occurs |
| protected_switches |
Protected switches operated by this ProtectionEquipment |
| protection_equipment |
|
| protection_equipments |
Protection equipment used to protect specific conducting equipment |
| protective_action |
Set of ProtectiveAction belonging to a ProtectiveActionCollection |
| protective_action_adjustment |
|
| protective_action_collection |
|
| protective_action_com |
For the ProtectiveAction to be activated the condition for communication need... |
| protective_action_enabled |
|
| protective_action_equipment |
Protective action is controlling equipment |
| protective_action_regulation |
Enable/disable a regulating control or set new target value |
| provided_bilateral_iopoint |
ICCP information in a Bilateral table that will be exposed to a remote peer |
| provided_by |
|
| provider |
Provider of information to a remote peer |
| provider_bilateral_exchange |
Agreement to information provider |
| provider_id |
Unique identifier for the commodity provider |
| provisional_balance |
The balance of this account after taking into account any pending debits from... |
| pset |
If pinit < pset</... |
| psmn |
Minimum value of pressure set point static characteristic (Psmn) |
| psr_type |
The coded type of a power system resource |
| psrevents |
All events associated with this power system resource |
| psrtype |
Custom classification for this power system resource |
| pssin |
Selector of the Power System Stabilizer (PSS) input (PSSin) |
| psslim |
PSS limiter (psslim) |
| pt_class |
Potential transformer (PT) classification covering burden |
| pt_ratio |
Built-in voltage transducer ratio |
| public_x___certificate |
Is the Public Certificate used for mutual authentication between peers |
| published |
The date when the complete CIM canonical model is published and made availabl... |
| puc_number |
(if applicable) Public utilities commission (PUC) identification number |
| pulse_output |
True if device produces pulse outputs |
| pump_disch_at_max_head |
The pumping discharge under maximum head conditions, usually at full gate |
| pump_disch_at_min_head |
The pumping discharge under minimum head conditions, usually at full gate |
| pump_min_down_time |
The minimum down time for the pump in a pump storage unit |
| pump_min_up_time |
The minimum up time aspect for the pump in a pump storage unit |
|
|
| pump_power_at_max_head |
The pumping power under maximum head conditions, usually at full gate |
| pump_power_at_min_head |
The pumping power under minimum head conditions, usually at full gate |
| pump_rated_p |
The hydro plant's pumping rating active power for rated head conditions |
| pump_self_sched_mw |
Contains the PriceTaker, ExistingTransmissionContract, TransmissionOwnershipR... |
| pump_shutdown_cost |
The cost to shutdown a pump during the pump aspect of a pump storage unit |
| pump_shutdown_time |
The shutdown time (minutes) of the pump aspect of a pump storage unit |
| pump_vibration |
Pump vibration, with typical values being: nominal, high |
| pumping_cost |
|
| pumping_factor |
Pumping factor for pump storage units, conversion factor between generating a... |
| purchase_date |
Date the asset was purchased |
| purchase_date_time |
Date and time asset was purchased |
| purchase_order_number |
Purchase order identifier |
| purchase_price |
Purchase price of asset |
| purchase_time_max |
Maximum purchase time in number of trading intervals |
|
|
| purchase_time_min |
Minimum purchase time in number of trading intervals |
|
|
| purpose |
The purpose of this switching plan request |
| purpose_flag |
Nature of threshold data: |
|
|
| pymt_plan_amt |
Monthly amortized amount due during each billing cycle for the CustomerAccoun... |
| pymt_plan_type |
Type of payment plan |
| q |
The reactive power flow |
| q_constant_current |
Portion of reactive power load modelled as constant current |
| q_constant_impedance |
Portion of reactive power load modelled as constant impedance |
| q_constant_power |
Portion of reactive power load modelled as constant power |
| q_dist_factor |
Reactive power (MVAr) load distribution factor |
|
|
| q_frequency_exponent |
Exponent of per unit frequency effecting reactive power |
| q_injection |
The reactive power injected into the bus at this location in addition to inje... |
| q_pcc_control |
Kind of reactive power control |
| q_percent |
Part of the coordinated reactive control that comes from this machine |
| q_share |
Reactive power sharing factor among parallel converters on Uac control |
| q_voltage_exponent |
Exponent of per unit voltage effecting reactive power |
| qc |
No-load turbine flow at nominal head (Qc0) |
| qconoff |
Secondary voltage control state (Qc_on_off) |
| qfixed |
Reactive power of the load that is a fixed quantity |
| qfixed_pct |
Fixed reactive power as per cent of load group fixed reactive power |
| qlimiter |
|
| qmax |
Maximum reactive power (qmax) (> WindContQLimIEC |
| qmin |
Minimum reactive power (qmin) (< WindContQLimIEC |
| qmode |
|
| qn |
Rated flow (Qn) |
| qnl |
No-load flow at nominal head (qnl) (>= 0) |
| qo |
Excitation centre setting (QO) |
| qref |
Reactive power reference (QREF) |
| qregulator |
|
| quadratic_coefficient |
Loss estimate quadratic coefficient |
|
|
| qualif_asorder |
Processing Order for AS self-provisions for this region |
| qualification_flag |
Status of the qualification ('Y' = Active, 'N' = Inactive) |
|
|
| qualification_id |
Qualification identifier |
| qualification_requirements |
|
| qualification_status |
Scheduling coordinator qualification status, Qualified, Not Qualified, or Dis... |
| quality |
The quality of the information being provided |
| quantity |
The quantity of the asset if per unit length, for example conductor |
| quantity_uom |
The unit of measure for the quantity element of the line item |
| question_code |
The question code |
| question_remark |
Remarks to qualify the question in this situation |
| question_text |
For non-coded questions, the question is provided here |
| question_type |
The type of the question |
| quick_start_flag |
Quick start flag (Yes/No) |
| qz |
Desired value (setpoint) of reactive power, manual setting (Qz) |
| r |
Zero sequence branch-to-branch mutual impedance coupling, resistance |
| r_ac |
AC resistance per unit length of the conductor at 75 °C |
| r_d |
Direct-axis damper 1 winding resistance |
| r_dc |
DC resistance per unit length of the conductor at 20 °C |
| r_direct_subtrans |
Direct-axis subtransient resistance |
| r_direct_sync |
Direct-axis synchronous resistance |
| r_direct_trans |
Direct-axis transient resistance |
| r_ground |
The resistance of the fault between phases and ground |
| r_line_to_line |
The resistance of the fault between phases |
| r_q |
Quadrature-axis damper 2 winding resistance |
| r_quad_subtrans |
Quadrature-axis subtransient resistance |
| r_quad_sync |
Quadrature-axis synchronous resistance |
| r_quad_trans |
Quadrature-axis transient resistance |
| ra |
Stator resistance (Ra) |
| radio |
Radio address |
| radius |
Outside radius of the wire |
| raise_lower_commands |
The Commands using the set for translation |
| raise_ramp_rate |
Maximum Up ramp rate in MW/min |
|
|
| raise_reg_margin_reqt |
Raise regulating margin requirement in MW, the amount of generation that can ... |
| ramp_curve_type |
Ramp curve type |
| ramp_interval |
Ramping time interval for the specific market product type specified by marke... |
| ramp_rate_control |
If set to TRUE, the rampRateControl function is supported |
| ramp_rate_curve |
|
| ramp_rate_limit |
The ramp rate limit for the unit in MWs per minute |
| ramp_rate_type |
How ramp rate is applied (e |
| randomisation |
Kind of randomisation to be applied to the end device control actions to be e... |
| rank |
Ranking in comparison to other switching plans |
| rate |
Standard usage rate for the type of vehicle |
| rate_label |
Label of the current billing rate specified by commodity provider |
| rated_apparent_power |
Rated apparent power |
| rated_capacity_p |
The CAES plant's gross rated generating capacity |
| rated_current |
Current flow that this usage point is configured to deliver |
| rated_e |
Full energy storage capacity of the battery |
| rated_frequency |
Frequency for which switch is rated |
| rated_gross_max_p |
The unit's gross rated maximum capacity (book value) |
| rated_gross_min_p |
The gross rated minimum generation level which the unit can safely operate at... |
| rated_idc |
Rated converter DC current, also called IdN |
| rated_impulse_withstand_voltage |
Rated impulse withstand voltage, also known as BIL (Basic Impulse Level) |
| rated_interrupting_time |
Switch rated interrupting time in seconds |
| rated_line_to_ground_voltage |
Rated line-to-ground voltage |
| rated_mechanical_power |
Rated mechanical power (Pr in IEC 60909-0) |
| rated_net_max_p |
The net rated maximum capacity determined by subtracting the auxiliary power ... |
| rated_p |
The rated output active power of the cogeneration plant |
| rated_power |
Active power that this usage point is configured to deliver |
| rated_power_factor |
Power factor (nameplate data) |
| rated_reactive_power |
Rated reactive power |
| rated_s |
Normal apparent power rating |
| rated_u |
Rated voltage: phase-phase for three-phase windings, and either phase-phase o... |
| rated_udc |
Rated DC device voltage |
| rated_voltage |
Rated voltage |
| rating_description |
the resource's demand response rating description |
| rating_set |
Rating set numbers |
|
|
| rating_specification |
|
| rating_type |
the type of performance rating, e |
| rating_value |
the resource's demand response rating |
| ratings |
UserAttributes used to specify ratings of the asset covered by this specifica... |
| ratio |
The voltage at the tap step divided by rated voltage of the transformer end h... |
| ratio_tap_changer |
Ratio tap changer associated with this transformer end |
| ratio_tap_changer_table |
The tap ratio table for this ratio tap changer |
| ratio_tap_changer_table_point |
Points of this table |
| rc |
Resistive component of compensation of a generator (... |
| rcd_info |
Information on remote connect disconnect switch |
| rcij |
Resistive component of compensation of generator associ... |
| rclose |
Minimum valve closing rate (Rclose) |
| rcmn |
Minimum fuel flow (RCMN) |
| rcmx |
Maximum fuel flow (RCMX) |
| rcrfd |
Ratio of field discharge resistance to field winding resistance ([rc / rfd... |
| rdown |
Maximum rate of load limit decrease (Rdown) |
| rdroop |
Resistive component of voltage drop impedance (rdroop</i... |
| reactive_capability_curve |
The reactive capability curve used by this equivalent injection |
| reactive_capability_curves |
All available reactive capability curves for this synchronous machine |
| reactive_power |
High voltage source reactive injection |
| reactive_power_dispatch |
If set to TRUE, the reactivePowerDispatch function is supported |
| read_cycle |
Cycle day on which the meter for this usage point will normally be read |
| read_route |
Identifier of the route to which this usage point is assigned for purposes of... |
| reading |
Reading value to which this quality applies |
| reading_qualities |
All qualities of this reading |
| reading_quality_type |
Type of this reading quality |
| reading_type |
All reading types for the meter read schedule |
| reading_types |
All reading types required to be collected by this metrology requirement |
| readings |
All reading values with this type information |
| ready_for_use_date |
Date of most recent asset transition to ready for use state |
| real_power_dispatch |
If set to TRUE, the realPowerDispatch function is supported |
| reason |
Reason code or explanation for why an object went to the current status 'valu... |
| reason_for_test |
Reason for performing test |
| receipt |
The receipted payment for which this transaction has been recorded |
| receipt_pnode |
|
| receipt_point_p |
Receipt point active power |
| receipt_transaction_bids |
|
| receipts |
All Receipts recorded for this Shift |
| receipts_grand_total_bankable |
Total of amounts receipted during this shift that can be manually banked (cas... |
| receipts_grand_total_non_bankable |
Total of amounts receipted during this shift that cannot be manually banked (... |
| receipts_grand_total_rounding |
Cumulative amount in error due to process rounding not reflected in receiptsG... |
| receive_dynamic_schedules |
A control area can receive dynamic schedules from other control areas |
| receive_sub_control_area |
A control area can receive dynamic schedules from other control areas |
| received_date |
Date the asset was received and first placed into inventory |
| received_date_time |
Date payment was received from client |
| received_time |
Timestamp indicating the time at which the instruction was received |
| receiver_reference |
Reference to the entity that is the recipient of 'amount' (for example, suppl... |
| reclose_delay |
Indicates the time lapse before the reclose step will execute a reclose |
| reclose_lockout_count |
Total number of phase reclose operations |
| reclose_sequences |
A breaker may have zero or more automatic reclosures after a trip occurs |
| reclose_step |
Indicates the ordinal position of the reclose step relative to other steps in... |
| reconditioning |
|
| reconditionings |
|
| recurrence_pattern |
Interval at which the scheduled action repeats (e |
| recurrence_period |
Duration between time points, from the beginning of one period to the beginni... |
| reduce |
If true, the adjusted value is an reduction |
| ref |
Reference value of reactive power or power factor (Ref) |
| reference_flag |
|
| reference_number |
Number of an invoice to be reference by this invoice |
| reference_priority |
Priority of unit for use as powerflow voltage phase angle reference bus selec... |
| reference_temp |
Reference temperature at which the output of the turbine was defined |
| reference_type |
Indication of which type of self schedule is being referenced |
| reg |
Permanent drop (Reg) |
| reg_branch |
For VAR, amp, or power factor locally controlled shunt impedances, the index ... |
| reg_branch_end |
For VAR, amp, or power factor locally controlled shunt impedances, the end of... |
| reg_branch_kind |
(For VAR, amp, or power factor locally controlled shunt impedances) Kind of r... |
| region |
The SubGeographicalRegion containing the substation |
| regions |
All sub-geographical regions within this geographical region |
| register |
All registers for quantities metered at this Usage Point |
| register_tier |
Register tier accumulating usage information |
| registered_generator |
|
| registered_generators |
|
| registered_inter_tie |
|
| registered_load |
|
| registered_resouce |
|
| registered_resource |
|
| registered_resources |
A registered resource injects power at one or more connectivity nodes related... |
| registers |
All registers for quantities metered by this end device function |
| registration_date |
For a market object, the date of registration of a contract, e |
| registration_status |
Registration Status of resource - Active, Mothballed, Planned, or Decommissio... |
| regulating_cond_eq |
The equipment that participates in this regulating control scheme |
| regulating_control |
The controls regulating this terminal |
| regulating_limit |
|
| regulating_limit_high |
The upper regulating limit incorporating any derate used by the RTD for the B... |
| regulating_limit_low |
The lower regulating limit incorporating any derate used by the RTD for the B... |
| regulation_capability |
Specifies whether or not the EquivalentInjection has the capability to regula... |
| regulation_down_ramp_rate |
Regulation down response rate in MW per minute |
| regulation_flag |
Specifies if the unit is regulating or not regulating or expected to be regul... |
| regulation_schedule |
Schedule for this regulating control |
| regulation_status |
Regulation Status (Yes/No) |
| regulation_target |
The target voltage for voltage regulation |
| regulation_up_ramp_rate |
Regulation up response rate in MW per minute |
| reheater_tc |
Second reheater time constant |
| relative_time_interval |
(if interval-based) A point in time relative to scheduled start time in 'Time... |
| relay_delay_time |
The time delay from detection of abnormal conditions to relay operation |
| relays_programming |
True if relays programming function is supported |
| released_by_supervisor |
Supervisor that released this safety document |
| released_date_time |
Date and time this safety document has been released |
| released_safety_documents |
All safety documents released to this supervisor |
| released_to_supervisor |
Supervisor to which this safety document is released |
| relec |
Steady-state droop, PU, for electrical power feedback (Relec) |
| reliability_infos |
|
| remark |
Pertinent information regarding the current 'value', as free form text |
| remarks |
freeform comments related to the dispatch to perform field work |
| remedial_action_scheme |
|
| remote |
Selector to apply automatic calculation in secondary controller model (rem... |
| remote_control |
The remote point controlling the physical actuator |
| remote_controlled |
Set to true if the actuator is remotely controlled |
| remote_input_signal |
Input signal coming from this terminal |
| remote_points |
Remote points this Remote unit contains |
| remote_signal_type |
Type of input signal |
| remote_source |
Link to the physical telemetered point associated with this measurement |
| remote_unit |
Remote unit this point belongs to |
| remote_unit_type |
Type of remote unit |
| remote_units |
RTUs may be attached to communication links |
| removal_date |
Date when the asset was last removed from service |
| remove_from_operation_indicator |
Removed From Operation Indicator |
| remove_weed |
True if weeds are to be removed around asset |
| removed_date |
Date and time asset most recently removed |
| repair_work_task |
Repair work task under which breaker item of this type is repaired |
| replacement_work_tasks |
All work tasks on replacement of this old asset |
| reportable |
|
| reported_date_time |
(used only when there are detailed auditing requirements) Date and time at wh... |
| reported_start_time |
The earliest start time of the Outage - as reported by some system or individ... |
| reported_state |
This is the state of market run activity as reported by market systems to the... |
| reporting_capability |
One of the reporting capabilities of this monitoring station |
| reporting_group |
Reporting groups to which this power system resource belongs |
| reporting_interval_period |
Number of units of time making up reporting period |
| reporting_interval_type |
Unit of time in which reporting period is expressed |
| reporting_kind |
Indicates how the customer reported trouble |
| reporting_method |
Indicates how the weather station reports observations |
| reporting_super_group |
Reporting super group to which this reporting group belongs |
| reporting_temperature |
Reporting temperature of related analog value if different from reporting tem... |
| req_max_mw |
Region requirement maximum limit |
|
|
| req_min_mw |
Region requirement minimum limit |
|
|
| req_notice_time |
Time period that is required from an order to reduce a load to the time that ... |
| request_date_time |
Date and time work was requested |
| requested_window |
Requested date and time interval for activity execution |
| requesting_organization |
The organization that requested the switching plan |
| require_autorun |
|
| resells_energy_product |
A Marketer may resell an EnergyProduct |
| reserve_demand_curve |
|
| reserve_req |
|
| reserve_req_curve |
|
| reserve_reqs |
Market product associated with reserve requirement must be a reserve or regul... |
| reserve_requirement_type |
Reserve requirement type that the max and curve apply to |
| reservoir |
Generators discharge water to or pumps are supplied water from a downstream r... |
| reset_kind |
Kind of reset mechanisim of this fault indicator |
| resistance |
Resistance of the DC line segment |
| resistive_loss |
It is converter’s configuration data used in power flow |
| resold_by_marketer |
A Marketer may resell an EnergyProduct |
| resolution |
The number of units of time that compose an individual step within a period |
| resolved_date_time |
Date and time this trouble ticket has been resolved |
| resorce_performance_global_factor |
|
| resource_adequacy_flag |
Indication that this resource participates in the resource adequacy function |
| resource_ancillary_service_qualification |
RegisteredResources are qualified for resource ancillary service types (which... |
| resource_award_instruction |
|
| resource_bid |
|
| resource_capacity |
|
| resource_certification |
|
| resource_clearing |
|
| resource_deployment_status |
|
| resource_dispatch_results |
|
| resource_group |
|
| resource_group_reqs |
|
| resource_groups |
|
| resource_load_following_inst |
|
| resource_loading_type |
Resource loading curve type |
|
|
| resource_mw |
Resource MW output at the end of previous clearing period |
| resource_operation_maintenance_cost |
|
| resource_performance_evaluation |
|
| resource_performance_evaluations |
|
| resource_performance_ratings |
|
| resource_performance_time_series_factors |
|
| resource_response_mw |
The MW amount the resource can contribute for this deployment |
| resource_startup_cost |
|
| resource_status |
Interval Test Status |
|
|
| resource_sub_type |
Unit sub type used by Settlements or scheduling application |
| resource_verifiable_costs |
|
| response_methods |
|
| restricted_value |
Restricted (new) value; includes unit of measure and potentially multiplier |
| retained |
Branch is retained in the topological solution |
| retired_date |
Date the asset is permanently retired from service and may be scheduled for d... |
| retired_reason |
Reason asset retired |
| revenue_kind |
(accounting) Kind of revenue, often used to determine the grace period allowe... |
| reverse_flow |
True if reverse flow function is supported |
| reverse_line_drop_r |
Line drop compensator resistance setting for reverse power flow |
| reverse_line_drop_x |
Line drop compensator reactance setting for reverse power flow |
| reverse_switching_date_time_interval |
The date when the switching to energize equipment is performed |
| reversed_id |
(if 'kind' is transactionReversal) Reference to the original transaction that... |
| reversible |
Indicates for converter drive motors if the power can be reversible |
| revision |
revision level for this version |
| revision_author |
Person who made the change |
| revision_date_time |
Date and time of the change |
| revision_history |
|
| revision_number |
Revision number for this document |
| revision_reason |
Reason for making the change |
| rex |
Effective output resistance (Rex) |
| rf_aux |
Coefficient for modelling the effect of off-nominal frequency and voltage on ... |
| rfd |
Field winding resistance |
| rgate |
Steady-state droop, PU, for governor output feedback (Rgate) |
| rground |
(for Yn and Zn connections) Resistance part of neutral impedance where 'groun... |
| rhp |
HP governor droop (Rhp) (> 0) |
| right_digit_count |
Number of digits (dials on a mechanical meter) to the right of the decimal pl... |
| right_of_ways |
All rights of way this land property has |
| rights |
The rights of use the transmission capacity acquired in an auction |
| risk_factor_cost |
The opportunity cost associated with the return in monetary unit |
| river_outlet_works |
River outlet works for riparian right releases or other purposes |
| river_system |
River System the Resource is tied to |
| rlp |
LP governor droop (Rlp) (> 0) |
| rmax |
Maximum fuel valve opening rate (Rmax) |
| rmin |
Minimum rotor resistance (rmin) (< WindContRotorR... |
| rmnrflag |
Reliability must not run (RMNR) flag: indicated whether the RMR unit is set a... |
| rmrdetermination |
|
| rmrflag |
Reliability must run (RMR) flag: indicates whether the unit is RMR; Indicates... |
| rmrheat_rate_curve |
|
| rmrmanual_indicator |
Indicates the RMR Manual pre-determination status [Y/N] |
|
|
| rmroperator_input |
|
| rmrstart_up_cost_curve |
|
| rmrstart_up_energy_curve |
|
| rmrstart_up_fuel_curve |
|
| rmrstart_up_time_curve |
|
| rmtflag |
Reliability must take (RMT) flag (Yes/No): indicates whether the unit is RMT |
|
|
| rn |
Negative sequence Thevenin resistance |
| rod_pattern |
Rod pattern |
| rod_pattern_constant |
Constant associated with rod pattern |
| roles |
All roles of this person |
| room_number |
Room number of location |
| root_cause |
Root cause of asset failure |
| root_origin |
Root origin of problem determined during diagnosis |
| root_remark |
Remarks pertaining to root cause findings during problem diagnosis |
| ropen |
Maximum valve opening rate (Ropen) |
| rotating_machine |
A synchronous machine may operate as a generator and as such becomes a member... |
| rotation |
Sets the angle of rotation of the diagram object |
| rotor_type |
Type of rotor on physical machine |
| round_off |
|
| rounding |
Totalised monetary value of all errors due to process rounding or truncating ... |
| route |
|
| routes |
|
| row |
The matrix element’s row number, in the range 1 to PerLengthPhaseImpedance |
| rperm |
Permanent droop (Rperm) |
| rpg |
Permanent droop for governor output feedback (R-Perm-Gate) |
| rpp |
Permanent droop for electrical power feedback (R-Perm-Pe) |
| rr |
Damper 2 winding resistance |
| rselect |
Feedback signal for droop (Rselect) |
| rsmimn |
Minimum value of integral regulator (Rsmimn) |
| rsmimx |
Maximum value of integral regulator (Rsmimx) |
| rtemp |
Temporary droop (Rtemp) |
| rto |
|
| rtos |
|
| ruc_gross_settlement |
Metered Sub-System (MSS) Load Following may select Net vs |
| ruc_procurement |
Indicates that RUC will be procured by the ISO or self provided |
| rucaward |
The RUC Award of a resource is the portion of the RUC Capacity that is not un... |
| rucaward_instruction |
|
| ruccapacity |
The RUC Capacity of a resource is the difference between (i) the RUC Schedule... |
| rucschedule |
The RUC Schedule of a resource is its output level that balances the load for... |
| ruczone |
|
| rule_id |
|
| run_indicator_dop |
Indication of DOP validity |
| run_state |
This is the state controlled by market defintion service |
| run_type |
|
| run_version |
|
| rup |
Maximum rate of load limit increase (Rup) |
| rvgmn |
Minimum value of integral regulator (Rvgmn) |
| rvgmx |
Maximum value of integral regulator (Rvgmx) |
| rx_locked_rotor_ratio |
Locked rotor ratio (R/X) |
| rymn |
Minimum valve opening (RYMN) |
| rymx |
Maximum valve opening (RYMX) |
| s_vccontrol_mode |
SVC control mode |
| safety_documents |
All safety documents applicable to this swtiching plan |
| sample_container |
Type of sample container |
| sat_direct_subtrans_x |
Direct-axis subtransient reactance saturated, also known as Xd"sat |
| sat_direct_sync_x |
Direct-axes saturated synchronous reactance (xdsat); reciprocal of short-circ... |
| sat_direct_trans_x |
Saturated Direct-axis transient reactance |
| saturation_factor |
Saturation factor at 120% of rated terminal voltage (S12) (>= Rotat... |
| saturation_factor___qaxis |
Quadrature-axis saturation factor at 120% of rated terminal voltage (S12q<... |
| saturation_factor_qaxis |
Quadrature-axis saturation factor at rated terminal voltage (S1q) (>... |
| sbase |
Apparent power of the unit (Sbase) (> 0) |
| scada_quality_code |
The quality code for the given Analog Value |
| scalar_denominator |
(if scalar is rational number) When 'IntervalReading |
| scalar_float |
(if scalar is floating number) When multiplied with 'IntervalReading |
| scalar_numerator |
(if scalar is integer or rational number) When the scalar is a simple intege... |
| scale_kind |
The scoring scale kind |
| scaling_percent |
The percentage scaling of the source limit to compute the target limit |
| scan_interval |
The time interval between scans |
| sched_override |
If specified, override schedule and perform this task in accordance with inst... |
| schedule_interval |
Schedule date and time interval |
| schedule_type |
Schedule type |
| scheduled_event_data |
Specification for this scheduled event |
| scheduled_events |
Scheduled event related to this asset |
| scheduled_interval |
(if control has scheduled duration) Date and time interval the control has be... |
| scheduled_limit_dependency |
|
| scheduled_limit_values |
The scheduled limit values for this limit dependency |
| scheduled_limits |
The scheduled limits associated with the season |
| scheduled_mw |
total MW schedule at the pnode |
|
|
| scheduling_coordinator |
|
| scheduling_coordinator_user |
|
| scid |
This is the short name or Scheduling Coordinator ID field |
| scope |
Indicates if the Point is global scoped (e |
| screening_flag |
sceening flag for outage |
|
|
| sdb |
Unintentional deadband location |
| se |
Saturation factor at E2 (S[E2</... |
| seal_number |
(reserved word) Seal number |
| sealing_warranty_expires_date |
Date sealing warranty expires |
| seals |
All seals applied to this asset container |
| season |
Season for the Schedule |
| season_day_type_schedules |
Schedules that use this DayType |
| second_terminal |
The starting terminal for the calculation of distances along the second branc... |
| secondary_address |
Secondary address of the location |
| secondary_device_timing |
Timing for the control actions performed by devices that are responding to ev... |
| secondary_fls_rating |
Full load secondary (FLS) rating for secondary winding |
| secondary_quantity |
Secondary quantity identified for a point |
| secondary_ratio |
Ratio for the secondary winding tap changer |
| section |
Town section |
| section_number |
The number of the section |
| sections |
Shunt compensator sections in use |
| secured_structure |
The secured structure supported by this structure support |
| security_constraint_limit |
|
| security_constraint_sum |
|
| security_constraints |
|
| security_constraints_linear |
|
| see |
Saturation parameter (SE[E2... |
| seefd |
Exciter saturation function value at the corresponding exciter voltage, E<... |
| segment_mw |
Mitigated bid segment MW value |
|
|
| segment_number |
Mitigated Bid Segment Number |
|
|
| self_market_document |
|
| self_sched_mw |
Self scheduled value |
|
|
| self_sched_spt_resource |
Price Taker Export Self Sched Support Resource |
|
|
| self_sched_type |
This attribute is used to specify if a bid includes a self sched bid |
| self_schedule_breakdown |
|
| self_schedule_mw |
Aof AS, selfScheduleMW = AS Self-Provided |
|
|
| self_series |
|
| send_dynamic_schedules |
A control area can send dynamic schedules to other control areas |
| send_sub_control_area |
A control area can send dynamic schedules to other control areas |
| sensing_phase_code |
Phases that are measured for controlling the device |
| sensitivity |
Unit sencivity factor |
| sensitivity_price_curve |
|
| sensor_accuracy |
The limit, expressed as a percentage of the sensor maximum, that errors will ... |
| sensor_maximum |
The maximum value the telemetry item can return |
| sensor_minimum |
The minimum value the telemetry item can return |
| sequence |
|
| sequence_number |
The sequence number of the argument in an operation |
| serial_number |
Serial number of this asset |
| series |
|
| series_equipment_dependent_limit |
Calculation in which the refernce to equipment applies |
| service_category |
Service category delivered by this usage point |
| service_delivery_remark |
Remarks about this usage point, for example the reason for it being rated wit... |
| service_end |
The end date of service provided, if periodic |
| service_kind |
|
| service_location |
The sevice location at which the assets exist |
| service_locations |
All service locations regulated by this customer agreement |
| service_multipliers |
All multipliers applied at this usage point |
| service_priority |
Priority of service for this usage point |
| service_request |
All service requests for the customer |
| service_requirement |
Explanation of the requirement and conditions for satisfying it |
| service_size |
The size or quantity requested by the customer; for example, 200 AMPS for ele... |
| service_start |
The start date of service provided, if periodic |
| service_supplier |
ServiceSupplier (utility) utilising this usage point to deliver a service |
| service_units_energy |
Actual amount of service units that is being paid for |
| service_units_error |
Number of service units not reflected in 'serviceUnitsEnergy' due to process ... |
| set_value |
The adjustment is given by a new active value |
| settlement |
|
| settlements |
|
| seve |
Exciter saturation function value at the corresponding exciter voltage, V<... |
| severity |
Severity level of event resulting in this activity record |
| shadow_price |
Shadow Price ($/MW) for the commodity |
| shaft_power_hp |
Fraction of power from shaft 2 high pressure turbine output |
| shaft_power_ip |
Fraction of power from shaft 2 intermediate pressure turbine output |
| shaft_power_lp |
Fraction of power from shaft 2 second low pressure turbine output |
| share |
Share in percentage of total Market load for the selected time interval |
| sheath_as_neutral |
True if sheath / shield is used as a neutral (i |
| shield_material |
Material of the shield |
| shift_patterns |
|
| short_circuit_end_temperature |
Maximum permitted temperature at the end of SC for the calculation of minimum... |
| short_circuit_rotor_type |
Type of rotor, used by short circuit applications, only for single fed short ... |
| short_pf |
Generating unit short term economic participation factor |
| short_term_rating |
The Short Term Rating for the branch |
|
|
| short_term_s |
Apparent power that this winding can carry for a short period of time (in eme... |
| shunt_compensator |
Shunt compensator of this shunt compensator phase |
| shunt_compensator_action |
The shunt compensator action that is performed on the shunt compensator |
| shunt_compensator_control |
|
| shunt_compensator_dynamic_data |
|
| shunt_compensator_info |
|
| shunt_compensator_phase |
The individual phases models for the shunt compensator |
| shut_downs_max_day |
Maximum number of shutdowns per day |
| shut_downs_max_week |
Maximum number of shutdowns per week |
| shut_off_date_time |
Final date and time the service will be billed to the previous customer |
| shutdown_cost |
The fixed cost associated with committing a load reduction |
| shutdown_curve |
A thermal generating unit may have a shutdown curve |
| shutdown_date |
The date and time of the most recent generating unit shutdown |
| shutdown_flag |
Whether Combined Cycle Plant can be shut-down in this Configuration? |
| sibv |
Speed deadband (SIBV) |
| side_a_sub_control_area |
The SubControlArea is on the A side of a collection of metered points which d... |
| side_a_tie_lines |
The SubControlArea is on the A side of a collection of metered points which d... |
| side_b_sub_control_area |
The SubControlArea is on the B side of a collection of metered points which d... |
| side_b_tie_lines |
The SubControlArea is on the B side of a collection of metered points which d... |
| sign_date |
Date this agreement was consummated among associated persons and/or organisat... |
| simplified_pelton |
Simplified Pelton model simulation (Sflag) |
| simx |
Intercept valves transfer limit (Simx) |
| sink |
|
| sink_crrsegment |
|
| sink_flag |
This value will be set to YES if the referenced Cnode is defined as the sink ... |
| sink_reservation |
|
| site_access_problem |
Problems previously encountered when visiting or performing work on this loca... |
| site_multiplier |
This value provides for scaling of a response method's active power |
| size |
Size of this support structure |
| size_depth |
Depth measurement |
| size_description |
Describes the wire gauge or cross section (e |
| size_diameter |
Diameter measurement |
| size_length |
Length measurement |
| size_width |
Width measurement |
| skills |
|
| slope |
The characteristics slope of an SVC defines how the reactive power output cha... |
| smax |
Stabilizer limit output (smax) |
| smpmfinal_flag |
|
| smpmflag |
SMPM flag: indicates whether the resource is subject to the SMPM test (Yes/No... |
| sold_to |
The company to which the PTB transaction is sold |
| solid_insulation_weight |
Weight of solid insultation in transformer |
| solidfuel_percent_above_low_sustained_limit |
Percentage of Solid Fuel for operating above Low Sustained Limit (LSL) |
|
|
| solidfuel_percent_cold_startup |
Percentage of Solid Fuel for cold startup |
|
|
| solidfuel_percent_hot_startup |
Percentage of Solid Fuel for hot startup |
|
|
| solidfuel_percent_intermediate_startup |
Percentage of Solid Fuel for intermedite startup |
|
|
| solidfuel_percent_low_sustained_limit |
Percentage of Solid Fuel for operating at LSL |
|
|
| solved_angle |
Phase Shifter Angle |
| solved_interchange |
Pool MW Interchange |
|
|
| solved_losses |
Pool Losses MW |
|
|
| source |
Source gives information related to the origin of a value |
| source_crrsegment |
|
| source_flag |
This value will be set to YES if the referenced Cnode is defined as the sourc... |
| source_id |
The identifer of the source for this entry |
| source_operational_limit |
|
| source_operational_limit_type |
|
| source_operational_limit_type_scaling |
|
| source_reservation |
|
| span_length |
The legth of the span from the previous pole to this pole |
| special_need |
Special service needs for the person (contact) are described; examples includ... |
| species_type |
Pole species |
| specification |
|
| specifications |
|
| specimen |
Specimen on which lab testing done in determining results |
| specimen_id |
Identifier of specimen used in inspection or test |
| specimen_sample_date_time |
Date and time sample specimen taken |
| specimen_to_lab_date_time |
Date and time the specimen was received by the lab |
| speed |
The speed of the phenomenon |
| speed_rating |
Rated speed in number of revolutions |
| speed_reference_governor |
Type of turbine governor reference (Type) |
| speed_regulation |
Speed regulation |
| spill_travel_delay |
The spillway water travel delay to the next downstream reservoir |
| spill_way_gate_type |
Type of spillway gate, including parameters |
| spills_from_reservoir |
A reservoir may spill into a downstream reservoir |
| spills_into_reservoirs |
A reservoir may spill into a downstream reservoir |
| spillway_capacity |
The flow capacity of the spillway in cubic meters per second |
| spillway_crest_length |
The length of the spillway crest |
| spillway_crest_level |
Spillway crest level above which water will spill |
| spin_ramp_rate |
Response rate in MW per minute for spinning reserve |
| spin_reserve |
Spin Reserve used to procure energy |
| spinning_reserve_reqt |
Spinning reserve requirement in MW, spinning reserve is generating capability... |
| srmn |
Minimum valve opening (Srmn) |
| srmx |
Maximum valve opening (Srmx) |
| srsmp |
Intercept valves characteristic discontinuity point (Srsmp) |
| stage |
The stage for which this costType applies: estimated design, estimated actual... |
| stage_trigger |
|
| stage_trigger_armed |
|
| stage_trigger_com |
|
| standard_edition |
Edition of ASTM standard |
| standard_industry_code |
|
| standard_number |
ASTM standard number |
| standard_ramp_energy |
Standard ramping energy (MWH) |
| star_impedance |
(accurate for 2- or 3-winding transformers only) Pi-model impedances of this ... |
| start |
Start time of this interval |
| start_date |
Date tariff was activated |
| start_date_time |
Start date and time for action of this control |
| start_ign_fuel_curve |
The unit's startup model may have a startup ignition fuel curve |
| start_main_fuel_curve |
The unit's startup model may have a startup main fuel curve |
| start_operating_date |
Operating date and hour when the entitlement applies |
| start_ramp_curve |
The unit's startup model may have a startup ramp curve |
| start_time |
A real time marker that defines the starting time (typically it is the time o... |
| start_up_cost |
Total Start-up Cost ($) over the time horizon |
|
|
| start_up_cost_basis |
The cost basis for start up |
| start_up_cost_curve |
|
| start_up_cost_curves |
|
| start_up_cost_eligibility_flag |
|
| start_up_energy_curve |
|
| start_up_fuel_curve |
|
| start_up_ramp_rate |
Resource startup ramp rate (MW/minute) |
|
|
| start_up_time_curve |
|
| start_up_type |
Resource startup type: |
|
|
| start_ups_max_day |
Maximum number of startups per day |
| start_ups_max_week |
Maximum number of startups per week |
| start_value |
The lowest level of consumption that defines the starting point of this inter... |
| started_date_time |
Date and time work task was started |
| startup_cost |
Startup cost/price |
|
|
| startup_date |
The date and time of the most recent generating unit startup |
| startup_flag |
Whether Combined Cycle Plant can be started in this Logical Configuration? |
|
|
| startup_lead_time |
Start up lead time |
|
|
| startup_model |
A thermal generating unit may have a startup model |
| startup_priority |
Startup priority within control area where lower numbers indicate higher prio... |
| startup_time |
Time it takes to get the unit on-line, from the time that the prime mover mec... |
| state |
{ Approve |
|
|
| state_or_province |
Name of the state or province |
| static_compensating |
Static compensating characteristic (Cflag) |
| static_load_model_type |
Type of static load model |
| static_var_compensator |
Static Var Compensator to which Static Var Compensator dynamics model applies |
| static_var_compensator_dynamics |
Static Var Compensator dynamics model used to describe dynamic behaviour of t... |
| statisical_calculation |
The statistical calculation done at this order |
| stator_leakage_reactance |
Stator leakage reactance (Xl) (>= 0) |
| stator_resistance |
Stator (armature) resistance (Rs) (>= 0) |
| status |
Status of this asset |
| status_date |
Time and date for resourceStatus |
|
|
| status_kind |
Kind of work status |
| status_type |
This is the name of the status of the qualification and is used to display th... |
| stby_aux_p |
The unit's auxiliary active power consumption to maintain standby mode |
| steam |
Steam plant |
| steam_chest_tc |
Steam chest time constant |
| steam_flow_fg |
Steam flow feedback gain |
| steam_pressure_drop_lag_tc |
Steam pressure drop lag time constant |
| steam_pressure_fg |
Steam pressure feedback gain |
| steam_sendout_schedule |
A cogeneration plant has a steam sendout schedule |
| steam_supply_rating |
The steam supply rating in kilopounds per hour, if dual pressure boiler |
| steam_supplys |
Steam turbines may have steam supplied by a steam supply |
| steam_turbines |
Steam turbines may have steam supplied by a steam supply |
| steep_front_discharge_voltage |
Residual voltage during a current impulse with front time of 1 microsecond, a... |
| step |
Tap changer position |
| step_increment_quantity |
The minimum increment that can be applied for an increase in an activation re... |
| step_phase_increment |
Phase shift per step position |
| step_phase_shift_increment |
Phase shift per step position |
| step_position |
Voltage control capacitor step position |
|
|
| step_voltage_increment |
Tap step increment, in per cent of rated voltage of the power transformer end... |
| stock_item |
True if item is a stock item (default) |
| stop_date_time |
Stop date/time for this profile |
| stop_time |
Stop time and date for which bid is applicable |
| stored_e |
Amount of energy currently stored |
| strand_count |
Number of strands in the conductor |
| street_address |
Street address |
| street_detail |
Street detail |
| streetlights |
All streetlights attached to this pole |
| string_measurement |
Measurement to which this value is connected |
| string_measurement_values |
The values connected to this measurement |
| structure_supports |
Structure support for this structure |
| structures |
|
| style_number |
Style number of asset model |
| styled_objects |
A style can be assigned to multiple diagram objects |
| sub_category |
More specific nature of the reading value quality, as a further sub-categoris... |
| sub_control_area |
|
| sub_control_areas |
The interchange area may operate as a control area |
| sub_domain |
More specific nature of the event, as a further sub-categorisation of 'domain... |
| sub_load_area |
The SubLoadArea where the Loadgroup belongs |
| sub_load_areas |
The SubLoadAreas in the LoadArea |
| sub_projects |
|
| sub_step_sequence_number |
Supports compound switching steps that are made up of several sub steps |
| sub_type |
Sub-classification of the inherited 'type' for this AuxiliaryAgreement |
| subdivision |
(if applicable) Name, identifier, or description of the subdivision in which ... |
| subject |
Document subject |
| submit_from_scheduling_coordinator |
|
| submit_from_sctrade |
|
| submit_from_time_stamp |
Timestamp of submittal of submit From Scheduling Coordinator Trade to Market ... |
| submit_from_user |
Userid of the submit From Scheduling Coordinator trade |
|
|
| submit_to_scheduling_coordinator |
|
| submit_to_sctrade |
|
| submit_to_time_stamp |
Timestamp of submittal of submit To Scheduling Coordinator Trade to Market Pa... |
| submit_to_user |
Userid of the submit To Scheduling Coordinator trade |
|
|
| subnet |
This is the IP subnet mask which controls the local vs non-local routing |
| subsequent_delay |
For an LTC, the delay for subsequent tap changer operation (second and later ... |
| substation |
The substation of the voltage level |
| substations |
The substations in this sub-geographical region |
| substitution_resource_list |
|
| success |
True if asset has passed acceptance test and may be placed in or is in servic... |
| suffix |
A suffix for the person's name, such as II, III, etc |
| suite_number |
Number of the apartment or suite |
| sum |
|
| summary |
Summary counts of service points (customers) affected by this outage |
| super_compressibility_compensation |
True if device performs super compressibility compensation for metered quanti... |
| super_heater_capacity |
Secondary superheater capacity |
| super_heater_pipe_pd |
Superheater pipe pressure drop constant |
| superceded_by |
The project version that will supercede this project version |
| supercedes |
Project version that is being superceded |
| supplemental_energy |
Supplemental Energy procure by Real Time Dispatch |
| support_for_block |
Per IEC 60870-6-702: If true indicates support for device control |
| support_for_depriciated_block |
Per IEC 60870-6-702: If true indicates support for accounts |
| supports_autonomous_dst |
If true, autonomous daylight saving time (DST) function is supported |
| surge_tank_code |
A code describing the type (or absence) of surge tank that is associated with... |
| surge_tank_crest_level |
The level at which the surge tank spills |
| suspect |
A correlation function has detected that the value is not consistent with oth... |
| sv_injection |
The injection flows state variables associated with the topological node |
| sv_power_flow |
The power flow state variable associated with the terminal |
| sv_shunt_compensator_sections |
The state for the number of shunt compensator sections in service |
| sv_status |
The status state variable associated with this conducting equipment |
| sv_switch |
The switch state associated with the switch |
| sv_tap_step |
The tap step state associated with the tap changer |
| sv_voltage |
The state voltage associated with the topological node |
| svcuser_defined |
Proprietary user-defined model with which this parameter is associated |
| svmn |
Maximum regulator gate closing velocity (Svmn) |
| svmx |
Maximum regulator gate opening velocity (Svmx) |
| switch |
|
| switch_action |
Action changing status of this switch |
| switch_on_count |
The switch on count since the switch was last reset or initialized |
| switch_on_date |
The date and time when the switch was last switched on |
| switch_operation_cycle |
Time interval between consecutive switching operations |
| switch_phase |
The individual switch phases for the switch |
| switch_schedules |
A Switch can be associated with SwitchSchedules |
| switch_state_count |
Number of switch states represented by the composite switch |
| switch_status |
|
| switches |
Switches contained in this Composite switch |
| switching_action |
The switching actions that are associated with the switching plan |
| switching_event |
The switching event that the switching action is performed on |
| switching_impulse_discharge_voltage |
Residual voltage during a current impulse with front time of at least 30 micr... |
| switching_loss |
Switching losses, relative to the base apparent power 'baseS' |
| switching_order |
The switching order that specified the switching plan to be implemented |
| switching_plan |
The switching plan for the request |
| switching_plan_request |
The switching plan requested by the requesting organization |
| switching_plans |
All switching plans that lead to supply restoration due to this outage |
| switching_request_details |
The details of this switching plan request |
| switching_step |
The switching step that is associated to the switching action |
| switching_step_group |
The switching step group that contains the switching steps |
| switching_step_groups |
All groups of switching steps within this switching plan |
| switching_steps |
All switching steps this operator is responsible for |
| sync_cond_capable |
Is the Resource Synchronous Condenser capable Resource? |
|
|
| synchronous_machine |
Synchronous machine to which synchronous machine dynamics model applies |
| synchronous_machine_dynamics |
Synchronous machine dynamics model used to describe dynamic behaviour of this... |
| synchronous_machine_user_defined |
Proprietary user-defined model with which this parameter is associated |
| synchronous_machines |
Synchronous machines this Prime mover drives |
| sys_load_distribu_factor |
|
| system_id |
Identification of the system which has declared the issue with the data or pr... |
| t |
Water starting time (T4) (>= 0) |
| t_f |
Lead lag time constant (T4F) (>= 0) |
| t_hp |
HP reheater time constant (T5hp) (>= 0) |
| t_if |
Exciter current feedback time constant (T1IF) (>=... |
| t_lp |
LP reheater time constant (T5lp) (>= 0) |
| t_m |
Input time constant (T4M) (>= 0) |
| t_mom |
Speed time constant (T4MOM) (>= 0) |
| ta |
Acceleration limiter time constant (Ta) (> 0) |
| tac |
Fuel control time constant (Tac) (>= 0) |
| tacarea |
|
| tact |
Actuator time constant (Tact) (>= 0) |
| tag_action |
Tag action associated with this tag |
| tagged_psrs |
All power system resources tagged through this clearance |
| tailbay_loss_curve |
A hydro generating unit has a tailbay loss curve |
| tam |
Intercept valves rate opening time (Tam) (>= 0) |
| tan |
Discontinuous controller time constant (TAN) (>= ... |
| taoff |
Time that adjuster pulses are off (TAOFF) (>= 0) |
| taon |
Time that adjuster pulses are on (TAON) (>= 0) |
| tap_changer |
The tap changer associated with the tap step state |
| tap_changer_control |
The regulating control scheme in which this tap changer participates |
| tap_changer_dynamic_data |
|
| tap_position |
Tap position of the phase shifter, high-side tap position of the transformer,... |
| tap_schedules |
A TapChanger can have TapSchedules |
| tape_lap |
Percentage of the tape shield width that overlaps in each wrap, typically 10%... |
| tape_thickness |
Thickness of the tape shield, before wrapping |
| target_alpha |
Target firing angle |
| target_deadband |
This is a deadband used with discrete control to avoid excessive update of co... |
| target_gamma |
Target extinction angle |
| target_idc |
DC current target value |
| target_level_schedule |
A reservoir may have a water level target schedule |
| target_object |
The registered CIM object |
| target_operational_limit |
|
| target_operational_limitm_type_scaling |
|
| target_phase_pcc |
Phase target at AC side, at point of common coupling |
| target_power_factor_pcc |
Power factor target at the AC side, at point of common coupling |
| target_ppcc |
Real power injection target in AC grid, at point of common coupling |
| target_pwmfactor |
Magnitude of pulse-modulation factor |
| target_qpcc |
Reactive power injection target in AC grid, at point of common coupling |
| target_udc |
Target value for DC voltage magnitude |
| target_upcc |
Voltage target in AC grid, at point of common coupling |
| target_value |
The target value specified for case input |
| target_value_unit_multiplier |
Specify the multiplier for used for the targetValue |
| targeting_cimdata_object |
Data objects registered |
| tariff_cycle |
The frequency at which the tariff charge schedule is repeated |
| tariff_profiles |
All tariff profiles defined by this time tariff interval |
| tariffs |
All tariffs used by this pricing structure |
| tase_bilateral_table |
Bilateral table agreement that includes the informational message |
| tase_version |
Specifies the version of the TASE |
| task_kind |
Kind of work |
| tatb |
Gain reduction ratio of lag-lead element ([Ta / Tb]) |
| tax_amount |
The tax on services taken |
| tax_exemption |
True if this pricing structure is not taxable |
| tb |
Turbine lag time constant (Tb) (> 0) |
| tbkr |
Circuit breaker operating time (Tbkr) (>= 0) |
| tblade |
Blade servo time constant (Tblade) (>= 0) |
| tc |
Damping time constant for “Canay” reactance (>= 0) |
| tcd |
Compressor discharge time constant (Tcd) (>= 0) |
| tcm |
Fuel control time constant (Tcm) (>= 0) |
| tcpaccess_point |
The association allows a certificate to be bound for use by TLS |
| tcul_control_mode |
Specifies the regulation control mode (voltage or reactive) of the RatioTapCh... |
| td |
Temperature controller derivative gain (Td) (>= 0) |
| tdc |
Derivative time constant of pressure regulator (Tdc) (>= 0) |
| tdelay |
Time constant (Tdelay) (>= 0) |
| tdgov |
Governor derivative controller time constant (Tdgov) (>= 0) |
| tdp |
Derivative time constant of the power controller (Tdp) (>= 0) |
| tdr |
Lag time constant (TDR) (>= 0) |
| tdv |
Distributive valve time lag time constant (Tdv) (>= 0) |
| tdvs |
Time delay after deep voltage sags (TDVS)... |
| te |
Exciter time constant, integration rate associated with exciter control (T... |
| technology |
Kind of communication technology |
| telim |
Selector for the limiter on the block (1/sTe) |
| temp_load_following_down_manual_cap |
temporarily manually entered LFD capacity |
|
|
| temp_load_following_up_manual_cap |
temporarily manually entered LFU capacity |
| temperature |
Temperature at which the test is conducted |
| temperature_compensation |
True if device performs temperature compensation for metered quantities |
| temperature_dependent_limit_table |
|
| temperature_limit_table_point |
|
| ten |
Electro hydraulic transducer (Ten) (>= 0) |
| ten_min_auxillary_data |
|
| tender |
Payment tender this card is being used for |
| tenders |
All payments received in the form of tenders recorded by this receipt |
| teng |
Transport time delay for diesel engine used in representing diesel engines wh... |
| terminal |
The terminals associated with this bus name marker |
| terminal_constraint_term |
|
| terminals |
Terminals interconnected with zero impedance at a this connectivity node |
| terminate_date |
Date/Time when record is no longer effective |
|
|
| termination_date |
|
| terms_payment |
Payment terms (e |
| tertiary_fls_rating |
Full load secondary (FLS) rating for tertiary winding |
| tertiary_ratio |
Ratio for the tertiary winding tap changer |
| test |
Measurement value is transmitted for test purposes |
| test_equipment_id |
Identity of lab equipment used to perform test |
| test_identifier |
1 - Global Price Test |
|
|
| test_kind |
Kind of test for this bushing |
| test_method |
The method of performing the market power monitoring |
| test_standard |
The lab test standard to which this asset health analog is related |
| test_standard_astm |
Which ASTM standard used to determine analog value result |
| test_standard_cigre |
Which CIGRE standard used to determine analog value result |
| test_standard_din |
Which DIN standard used to determine analog value result |
| test_standard_doble |
Which Doble standard used to determine analog value result |
| test_standard_epa |
Which EPA standard used to determine analog value result |
| test_standard_iec |
Which IEC standard used to determine analog value result |
| test_standard_ieee |
Which IEEE standard used to determine analog value result |
| test_standard_iso |
Which ISO standard used to determine analog value result |
| test_standard_laborelec |
Which Laborelec standard used to determine analog value result |
| test_standard_tappi |
Which TAPPI standard used to determine analog value result |
| test_standard_ukministry_of_defence |
Which UK Ministry of Defence standard used to determine analog value result |
| test_standard_wep |
Which WEP standard used to determine analog value result |
| test_variant |
Identification of variant of test method or standard if one is specified by t... |
| text |
The textual explanation corresponding to the reason code |
| text_message |
True if the displaying of text messages is supported |
| tf |
Fuel system time constant (Tf) (>= 0) |
| tfen |
Turbine rated exhaust temperature correspondent to Pm=1 PU (Tfen) |
| tfi |
Current transducer time constant (Tfi) (>= 0) |
| tfload |
Load-limiter time constant (Tfload) (> 0) |
| tfma |
Time interval of moving average window (TfMA) (>= 0) |
| tfp |
Time constant of the power controller (Tfp) (>= 0) |
| tg |
Gate servo time constant (Tg) (>= 0) |
| th |
Exciter field current limiter time constant (TH) (&g... |
| thermal_generating_unit |
A thermal generating unit may have a heat rate curve |
| thermal_generating_units |
A thermal generating unit may be a member of a cogeneration plant |
| thetaemin |
Minimum electrical generator torque (temin) |
| thetamax |
Maximum pitch angle (thetamax) (> WindContPitchAn... |
| thetamin |
Minimum pitch angle (thetamin) (< WindContPitchAn... |
| thetaomega |
Initial pitch angle (thetaomega0) |
| thetap |
Potential circuit phase angle (thetap) |
| thetauscale |
Voltage scaling factor of reset-torque (tuscale) |
| thetav |
Blade angle at twice rated wind speed (thetav2) |
| thetazero |
Pitch angle if the wind turbine is not derated (theta0</... |
| thp |
High pressure (HP) time constant of the turbine (Thp) (>= 0) |
| threshold_percentage |
The threshold percentage that should be used for compare with the percentage ... |
| threshold_type |
|
| threshold_value |
The threshold value that should be used for compare with the input value |
| throttle_pressure_factor |
Throttle pressure factor |
| throttle_pressure_sp |
Throttle pressure setpoint |
| ti |
Time constant (Ti4) (>= 0) |
| tia |
Feedback time constant (TIA) (>= 0) |
| tic |
Current PI controller integration time constant (TIc... |
| tie_flow |
The control area tie flows to which this terminal associates |
| tie_line_pf |
Generating unit economic participation factor |
| tie_lines |
A dynamic energy transaction can act as a pseudo tie line |
| tie_point_mwrating |
The MW rating of the tie point |
| tif |
Exciter current feedback time constant (TIF) (>= ... |
| time |
Time of notification - this is the time the notification was sent |
| time_constant |
The time constant for the turbine |
| time_delay |
Inverse time delay number 3 for current limit number 3 |
| time_in_status |
Time in market trading intervals the resource is in the state as of the end o... |
| time_interval |
Time interval |
|
|
| time_interval_duration |
The length of time for each interval in the dispatch schedule |
| time_interval_end |
End of the time interval n which bid is valid (yyyy-mm-dd hh24: mi: ss) |
|
|
| time_interval_length |
Trading time interval length |
| time_interval_period |
The time interval over which the CommodityPrice is valid, using the standard ... |
| time_interval_start |
Start of the time interval in which bid is valid (yyyy-mm-dd hh24: mi: ss) |
| time_interval_unit |
The unit of measure for the time axis of the dispatch schedule |
| time_of_use |
Time of Use flag of the CRR - Peak (ON), Offpeak (OFF) or all 24 hours (24HR) |
| time_period |
Start and end of the period for those readings whose type has a time attribut... |
| time_points |
Sequence of time points belonging to this time schedule |
| time_schedule |
All time schedules for the meter read schedule |
| time_schedules |
All time schedules for this work or work task |
| time_series |
|
| time_series_data_type |
Type of the time series data, e |
| time_series_description |
Optional description of the time series data, e |
| time_stamp |
The date/time this version was finalized and thus made immutable |
| time_step |
The time between each pair of subsequent regular time points in sequence orde... |
| time_tariff_intervals |
Tariff intervals to which this time-based charge has to be levied |
| time_zone |
The time zone code |
|
|
| time_zone_offset |
Time zone offset relative to GMT for the location of this end device |
| timestamp_dop |
DOP time stamp |
|
|
| tip |
Integral time constant of the power controller (Tip) (>= 0) |
| title |
Document title |
| title_held_by_marketer |
A Marketer holds title to an EnergyProduct |
| tj |
Exciter field current limiter time constant (TJ) (&g... |
| tk |
Voltage regulator time constant (TK) (>= 0) |
| tl |
Low band time constant (TL9) (>= 0) |
| tlp |
Low pressure (LP) time constant of the turbine (Tlp) (>= 0) |
| tltr |
Valve position averaging time constant (Tltr) (>= 0) |
| tm |
Compressor discharge volume time constant (Tm) (>= 0) |
| tmax |
Maximum turbine limit (Tmax) (> GovGAST2 |
| tmin |
Minimum turbine limit (Tmin) (< GovGAST2 |
| tmp |
Low pressure (LP) time constant of the turbine (Tmp) (>= 0) |
| tn |
Time constant (Tn) (> 0) |
| tnu |
Controller reset time constant (Tnu) (>= 0) |
| to_be_energised |
True if associated electrical equipment is intended to be energized while wor... |
| to_configuration |
|
| to_flowgate |
|
| to_mesh_impedance |
All mesh impedances between this 'from' and other 'to' transformer ends |
| to_mesh_impedances |
All mesh impedances between this 'from' and other 'to' transformer ends |
| to_phase |
Refer to the class description |
| to_sc |
|
| to_sctrade |
|
| to_sub_control_area |
|
| to_transformer_end |
All transformer ends this mesh impedance is connected to |
| to_transformer_end_infos |
All 'to' transformer end datasheets this mesh impedance for 'from' transforme... |
| to_transition_state |
|
| to_winding |
|
| to_winding_insulations |
|
| tob |
OEL lag time constant (TOB2) (>= 0) |
| toc |
OEL lead time constant (TOC2) (>= 0) |
| tomd |
Speed delay (TOMD) (>= 0) |
| tomegafiltp |
Filter time constant for generator speed measurement (Tomegafiltp... |
| tomegafiltrr |
Filter time constant for generator speed measurement (Tomegafi... |
| tomegaref |
Time constant in speed reference filter (Tomega,ref) (>=... |
| tomsl |
Speed time constant (TOMSL) (>= 0) |
| tool_cost |
Total tool costs associated with the work task |
| top_oil_temp |
Top oil temperature |
| topological_island |
A topological node belongs to a topological island |
| topological_node |
The topological nodes that belong to the reporting group |
| topological_nodes |
A topological node belongs to a topological island |
| total_cost |
Total Cost (Energy + AS) cost ($) by over the time horizon |
|
|
| total_count |
Number of all service (delivery) points affected by an outage |
| total_efficiency |
The efficiency of the unit in converting the fuel into electrical energy |
| total_interval |
|
| total_load |
Amount of load in the control zone |
|
|
| total_loss_mw |
Total MW losses in the company |
|
|
| total_net_interchange |
Amount of interchange for the control zone |
|
|
| total_power_adjustment |
Total active power adjustment (e |
| total_revenue |
Total bid revenue (startup_cost + no_load_cost + bid_pay) |
|
|
| total_ruc_cost |
The total RUC capacity cost for this interval |
|
|
| total_schedule |
Resource total upward schedule |
| total_tran_charge_max |
Maximum total transmission (congestion) charges in monetary units |
|
|
| total_transfer_capability |
The total transmission capability of a transmission path in the reference dir... |
| total_transmission_capacity |
Total Transmission Capacity |
|
|
| tou |
Time of use (TOU) bucket the reading value is attributed to |
| tou_tariff_intervals |
All time of use tariff intervals influenced by this consumption tariff interv... |
| tou_tier |
Clock time interval for register to beging/cease accumulating time of usage (... |
| tou_tier_name |
Name used for the time of use tier (also known as bin or bucket) |
| town_detail |
Town detail |
| tp |
Pilot servo valve time constant (Tp) (>= 0) |
| tpaero |
Time constant in aerodynamic power response (Tpaero)... |
| tpdo |
Direct-axis transient rotor time constant (T'do) (> SynchronousMach... |
| tpe |
Electrical power droop time constant (Tpe) (>= 0) |
| tpelec |
Electrical power transducer time constant (Tpelec) (> 0) |
| tpfc |
PF controller time delay (TPFC) (>= 0) |
| tpfiltp |
Filter time constant for power measurement (Tpfiltp3) (>... |
| tpfiltq |
Power measurement filter time constant (Tpfiltq) (&g... |
| tpfiltql |
Power measurement filter time constant for Q capacity (Tpfiltq... |
| tpfiltrr |
Filter time constant for power measurement (Tpfiltrr... |
| tpft |
Lead time constant in reference value transfer function (Tpft<... |
| tpfv |
Lag time constant in reference value transfer function (Tpfv</... |
| tpll |
Time constant for PLL first order filter model (TPLL... |
| tpo |
Transient rotor time constant (greater than tppo) |
| tpord |
Time constant in power order lag (Tpord) |
| tpordp_a |
Time constant in power order lag (Tpordp4A) (>= 0... |
| tpordp_b |
Time constant in power order lag (Tpordp4B) (>= 0... |
| tpost |
Length of time period where post fault reactive power is injected (T<i... |
| tppdo |
Direct-axis subtransient rotor time constant (T''do) (> 0) |
| tppo |
Sub-transient rotor time constant (greater than 0) |
| tppqo |
Quadrature-axis subtransient rotor time constant (T''qo) (> 0) |
| tpqo |
Quadrature-axis transient rotor time constant (T'qo) (> Synchronous... |
| tq |
Time constant of lag function of reactive power (TQ)... |
| tqord |
Time constant in reactive power order lag (Tqord) (&... |
| tr |
Time constant which is used for the combined voltage se... |
| trade |
|
| trade_date |
The trade date on which the settlement is run |
| trade_error |
|
| trade_product |
|
| trade_product_type |
PHY (Physical Energy Trade); |
|
|
| trade_quantity |
tradeQuantity: |
|
|
| trade_slice_id |
Segment of the CRR described in the current record |
| trade_status |
Resulting status of the trade following the rule engine processing |
| trade_type |
IST - InterSC Trade; |
|
|
| trading_day |
Market trading date |
|
|
| trading_hub_price |
|
| trading_hub_values |
|
| trading_period |
Trading period that describes the market, possibilities could be for an Energ... |
| tranmission_right_entitlement |
|
| transaction |
Transaction for which this snapshot has been recorded |
| transaction_bid |
|
| transaction_bid_clearing |
|
| transaction_bid_results |
|
| transaction_date |
The date the transaction occurs |
| transaction_date_time |
Date and time journal entry was recorded |
| transaction_type |
The type of transaction |
| transactions |
All transactions applying this pricing structure |
| transactions_grand_total |
Cumulative total of transacted amounts during this shift |
| transactions_grand_total_rounding |
Cumulative amount in error due to process rounding not reflected in transacti... |
| transactors |
All transactors this merchant account is registered with |
| transfer_interface |
|
| transfer_interface_solution |
|
| transfer_interface_solution_a |
|
| transfer_interface_solution_b |
|
| transfer_limit |
Transfer Interface + Limit |
|
|
| transfer_type |
Type of invoice transfer |
| transformer |
|
| transformer_application |
Type of network role transformer is playing in this deployment (applies to tr... |
| transformer_end |
All transformer ends connected at this terminal |
| transformer_end_info |
Transformer end datasheet used to calculate this transformer star impedance |
| transformer_end_infos |
Data for all the ends described by this transformer tank data |
| transformer_ends |
Transformer ends at the base voltage |
| transformer_failure_reason |
Reason for transformer failure |
| transformer_maintenance_kind |
Kind of transformer maintenance performed by this maintenance work task |
| transformer_observation |
|
| transformer_observations |
|
| transformer_repair_item |
Transformer component or problem area which is the focus of this maintenance ... |
| transformer_star_impedance |
Transformer star impedance calculated from this transformer end datasheet |
| transformer_tank |
Transformer this winding belongs to |
| transformer_tank_ends |
All windings of this transformer |
| transformer_tank_info |
Transformer tank data that this end description is part of |
| transformer_tank_infos |
Data for all the tanks described by this power transformer data |
| transformer_tanks |
All transformers that belong to this bank |
| transient_droop_time |
Transient droop time constant |
| transient_regulation |
Transient regulation |
| transmission_capacity |
|
| transmission_contract_right |
|
| transmission_corridor |
A transmission right-of-way is a member of a transmission corridor |
| transmission_interface_entitlement |
|
| transmission_mode |
Transmission mode to be used for this PAN display control |
| transmission_path |
|
| transmission_product_type |
Type of the transmission product |
| transmission_products |
A TransmissionProvider offers a TransmissionProduct |
| transmission_provider |
A TransmissionProvider offers a TransmissionProduct |
| transmission_reservation |
|
| transmission_right_chain |
|
| transmission_right_of_way |
|
| transmission_right_of_ways |
A transmission right-of-way is a member of a transmission corridor |
| transport_security_requirement |
If true, then transport level security as specified by IEC 62351-6 is require... |
| trate |
Turbine rating (Trate) |
| treated_date_time |
Date and time pole was last treated with preservative |
| treatment_kind |
Kind of treatment for this pole |
| treg |
Speed detector time constant (Treg) (>= 0) |
| trentitlement |
|
| trh |
Reheater time constant of the turbine (Trh) (>= 0) |
| trigger |
Trigger for this notification |
| trigger_condition |
|
| trip_amps |
Trip current (nominal) |
| trip_voltage |
Trip voltage in volts DC |
| trouble_code |
Trouble code (e |
| trouble_order |
The trouble order that is associated to the incident |
| trouble_reporter |
|
| trouble_reporter_type |
The type of person reporting the trouble |
| trouble_symptoms |
|
| trouble_symptoms_extent |
The extent of the problem being reported |
| trouble_symptoms_extent_other |
The extent of the problem being reported that does not fit any of the enumera... |
| trouble_symptoms_light |
The problem with lights being reported |
| trouble_symptoms_light_other |
The problem with lights being reported that does not fit any of the enumerati... |
| trouble_symptoms_pole |
The problem with pole being reported |
| trouble_symptoms_pole_other |
The problem with pole being reported that does not fit any of the enumeration... |
| trouble_symptoms_transformer |
The problem with transformer being reported |
| trouble_symptoms_transformer_other |
The problem with transformer being reported that does not fit any of the enum... |
| trouble_symptoms_tree |
The problem with tree being reported |
| trouble_symptoms_tree_other |
The problem with tree being reported that does not fit any of the enumeration... |
| trouble_symptoms_wire |
The problem with wire being reported |
| trouble_symptoms_wire_other |
The problem with wire being reported that does not fit any of the enumeration... |
| trouble_ticket |
|
| trouble_tickets |
All trouble tickets reporting this incident |
| trtype |
Transmission Right type - is this an individual contract right or a chain con... |
| ts |
Gate servo time constant (Ts) (>= 0) |
| tsa |
Temperature detection lead time constant (Tsa) (>= 0) |
| tsb |
Temperature detection lag time constant (Tsb) (>= 0) |
| tsi |
Time constant of radiation shield (Tsi) (>= 0) |
| tsw |
Stabilizer parameters (Tsw) (>= 0) |
| tt |
Temperature controller integration rate (Tt) (>= 0) |
| ttc |
Time constant of thermocouple (Ttc) (>= 0) |
| ttheta |
Pitch time constant (ttheta) (>= 0) |
| tturb |
Turbine time constant (Tturb) (>= 0) |
| tu |
UEL lag time constant (TU4) (>= 0) |
| tub |
UEL lag time constant (TUB2) (>= 0) |
| tuc |
UEL lead time constant (TUC2) (>= 0) |
| tufiltcl |
Voltage measurement filter time constant (Tufiltcl) ... |
| tufiltp |
Filter time constant for voltage measurement (Tufiltp3) (&g... |
| tufiltp_a |
Voltage measurement filter time constant (Tufiltp4A)... |
| tufiltp_b |
Voltage measurement filter time constant (Tufiltp4B)... |
| tufiltq |
Voltage measurement filter time constant (Tufiltq) (... |
| tufiltql |
Voltage measurement filter time constant for Q capacity (Tufil... |
| tul |
Time constant associated with optional integrator feedback input signal to UE... |
| tup |
Real power filter time constant (TUP) (>= 0) |
| tuq |
Reactive power filter time constant (TUQ) (>= 0) |
| tuqfilt |
Filter time constant for voltage-dependent reactive power (Tuq... |
| turbine_governor_dynamics |
Turbine-governor model associated with this synchronous machine model |
| turbine_governor_user_defined |
Proprietary user-defined model with which this parameter is associated |
| turbine_load_controller_dynamics |
Turbine load controller providing input to this turbine-governor |
| turbine_load_controller_user_defined |
Proprietary user-defined model with which this parameter is associated |
| turbine_rating |
Rated turbine active power |
| turbine_type |
Type of turbine |
| tuv |
Voltage filter time constant (TUV) (>= 0) |
| tv |
Servomotor integrator time constant (Tv) (>= 0) |
| tvarc |
Var controller time delay (TVARC) (>= 0) |
| tvd |
Voltage regulator derivative gain (Tvd) (>= 0) |
| tvhp |
Control valves servo time constant (Tvhp) (>= 0) |
| tvip |
Intercept valves servo time constant (Tvip) (>= 0) |
| tw |
Water inertia time constant (Tw) (>= 0) |
| twnc |
Water inertia time constant (Twnc) (>= 0) |
| twng |
Water tunnel and surge chamber inertia time constant (Twng) (>= 0) |
| two |
Time constant for crowbar washout filter (Two) (>... |
| twpffiltp |
Filter time constant for frequency measurement (TWPffiltp</sub... |
| twppfiltp |
Filter time constant for active power measurement (TWPpfiltp</... |
| twppfiltq |
Filter time constant for active power measurement (TWPpfiltq</... |
| twpqfiltq |
Filter time constant for reactive power measurement (TWPqfiltq... |
| twpufiltq |
Filter time constant for voltage measurement (TWPufiltq<... |
| tx |
Derivative feedback gain (Tx) (>= 0) |
| txft |
Lead time constant in reference value transfer function (Txft<... |
| txfv |
Lag time constant in reference value transfer function (Txfv</... |
| ty |
Time constant of fuel valve positioner (Ty) (>= 0) |
| type |
Utility-specific classification of Asset and its subtypes, according to their... |
| type_asset |
|
| type_asset_catalogue |
|
| type_assets |
|
| type_material |
|
| uc |
Line-to-line converter voltage, the voltage at the AC side of the valve |
| ucmax |
Maximum voltage reference limit (UCMAX) (> ExcRQB |
| ucmin |
Minimum voltage reference limit (UCMIN) (< ExcRQB |
| udb |
Voltage deadband upper limit (udb2) |
| udc |
Converter voltage at the DC side, also called Ud |
| udvs |
Voltage limit for hold UVRT status after deep voltage sags (uD... |
| uel |
Selector (UEL) |
| uelin |
UEL input (uelin) |
| uimax |
Maximum error (UImax) (> ExcSK |
| uimin |
Minimum error (UImin) (< ExcSK |
| umax |
Maximum voltage in voltage PI controller integral term (umax</... |
| umin |
Minimum voltage in voltage PI controller integral term (umin</... |
| umode |
|
| unavailability_schedule_depends_on |
|
| unavailability_schedule_impacts |
|
| unavailability_switch_action |
|
| unavailablity_schedule |
|
| underexcitation_limiter_dynamics |
Undrexcitation limiter model associated with this excitation system model |
| underexcitation_limiter_user_defined |
Proprietary user-defined model with which this parameter is associated |
| unit |
|
| unit_cost |
Unit cost for an asset model from a specific supplier, either for a unit cost... |
| unit_initial_conditions |
|
| unit_multiplier |
The unit multiplier of the measured quantity |
| unit_of_measure |
The UOM for the current value of the Bill Determinant |
| unit_status |
Output results from the case identifying the reason the unit was committed by... |
| unit_symbol |
The unit of measure of the measured quantity |
| unit_type |
Generating unit type: Combined Cycle, Gas Turbine, Hydro Turbine, Other, Phot... |
| unplanned_outage |
The unplanned outage that may be associated with the incidents |
| uo |
Maximum gate opening velocity (Uo) |
| uover |
Wind turbine over voltage protection activation threshold (uov... |
| up_time_max |
Maximum up time |
| up_transition |
Flag indicating whether this is an UP transition |
| update_time_stamp |
|
| update_type |
|
| update_user |
|
| updated |
|
| updated_ratings |
All updated ratings for this planned equipment outage |
| updip |
Voltage dip threshold for P-control (uPdip) |
| upll |
Voltage (uPLL2) below which the angle of the voltage... |
| upmax |
Limiter (Upmax) (> ExcELIN2 |
| upmin |
Limiter (Upmin) (< ExcELIN2 |
| upper_layer_public_x___certificate |
Certificate to be bound for use for Application layer mutual authentication |
| upper_limit |
resource energy ramping upper limit |
|
|
| upqumax |
Wind turbine voltage in the operation point where zero reactive current can b... |
| upstream_from_hydro_power_plants |
Generators are supplied water from or pumps discharge water to an upstream re... |
| uqdip |
Voltage threshold for UVRT detection in Q control (uqdip... |
| uref |
User-defined bias in voltage reference (uref0) |
| urmax |
Maximum controller output (URmax) (> ExcSK |
| urmin |
Minimum controller output (URmin) (< ExcSK |
| usage |
Usage of the associated wires |
| usage_kind |
Intended usage for this asset model |
| usage_mw |
Existing transmission contract usage MW value |
|
|
| usage_point |
All usage points for the meter read schedule |
| usage_point_group |
All usage point groups for the meter read schedule |
| usage_point_groups |
All groups to which this usage point belongs |
| usage_point_location |
Location of this usage point |
| usage_points |
All usage points connected to the electrical grid through this equipment |
| usages |
|
| use_emergency_schedule |
Use Emergency Schedule |
|
|
| use_limit_flag |
Use limit flag: indicates if the use-limited resource is fully scheduled (or ... |
| use_pushbutton |
True if pushbutton has to be used for connect |
| user_attributes |
|
| user_id |
User ID needed to log in, which can be for an individual person, an organisat... |
| utc_number |
Uniquely tracked commodity (UTC) number |
| utility_disclaimer |
This contains an disclaimers the utility would like to place on the data prov... |
| uunder |
Wind turbine under voltage protection activation threshold (uu... |
| uuvrt |
Dip detection threshold (uUVRT) |
| uv |
Line-to-line voltage on the valve side of the converter transformer |
| uwpqdip |
Voltage threshold for UVRT detection in Q control (uWPqdip</su... |
| v |
The voltage magnitude at the topological node |
| v_reg_line_line |
True if regulated voltages are measured line to line, otherwise they are meas... |
| va |
Maximum gate opening velocity (Va) |
| vadat |
Signal selector (VADAT) |
| vadjf |
Set high to provide a continuous raise or lower (VADJF</... |
| vadjmax |
Maximum output of the adjuster (VADJMAX) (> VAdjI... |
| vadjmin |
Minimum output of the adjuster (VADJMIN) (< VAdjI... |
| val |
Regulator voltage reference (VAL) |
| valid_for |
The interval for which the forecast is valid |
| valid_period |
The period of time for which the plan is valid |
| validity |
Validity of the measurement value |
| validity_interval |
Date and time interval this agreement is valid (from going into effect to ter... |
| value |
|
| value_alias_set |
The ValueAliasSet used for translation of a MeasurementValue |
| value_date_time |
Date and time at which the financial value was last established |
| value_description |
Description for the value2 contained within the TimeSeriesFactor |
| value_missing |
The indication of whether or not the quantity of this reading is missing |
| value_multiplier |
Multiplier for value2 |
| value_uninterrupted_service_energy |
Value of uninterrupted service (Cost per energy) |
| value_uninterrupted_service_p |
Value of uninterrupted service (Cost per active power) |
| value_unit |
Value2 units of measure |
| values |
The ValueToAlias mappings included in the set |
| values_interval |
Date and time interval of the data items contained within this meter reading |
| valve |
Nonlinear valve characteristic |
| valve_u |
Valve threshold voltage, also called Uvalve |
| valvmax |
Maximum gate opening (ValvMax) (> GovHydroFrancis |
| valvmin |
Minimum gate opening (ValvMin) (< GovHydroFrancis |
| vamax |
Maximum voltage regulator output (VAMAX) (> 0) |
| vamin |
Minimum voltage regulator output (VAMIN) (< 0) |
| vanmax |
Limiter for Van (VANMAX) |
| variable_cost |
The variable cost component of production per unit of ActivePower |
| variable_energy_resource |
Provides an indication that this resource is intending to participate in an i... |
| variable_portion |
The variable portion of this charge element, calculated as a percentage of th... |
| varistor_present |
Describe if a metal oxide varistor (mov) for over voltage protection is confi... |
| varistor_rated_current |
The maximum current the varistor is designed to handle at specified duration |
| varistor_voltage_threshold |
The dc voltage at which the varistor starts conducting |
| vav |
Maximum servomotor valve opening velocity (Vav) |
| vb_max |
Available exciter voltage limiter (Vb1max) (> 0) |
| vblim |
Vb limiter indicator |
| vbmax |
Maximum excitation voltage (VBMax) (> 0) |
| vc |
Maximum gate closing velocity (Vc) |
| vcl |
Stabilizer input cutoff threshold (Vcl) |
| vclmt |
Maximum output of the pf controller (VCLMT) |
| vcmax |
Maximum compounding voltage (Vcmax) |
| vcomp_ieeetype |
The standard IEEE type 2 voltage compensator of this compensation |
| vcu |
Stabilizer input cutoff threshold (Vcu) |
| vcv |
Maximum servomotor valve closing velocity (Vcv) |
| vdcmax |
Maximum DC voltage (Vdcmax) |
| vdcmin |
Minimum DC voltage (Vdcmin) |
| vdcol |
|
| vdmax |
Limiter (VDMAX) (> DiscExcContIEEEDEC2A |
| vdmin |
Limiter (VDMIN) (< DiscExcContIEEEDEC2A |
| ve |
Exciter alternator output voltages back of commutating reactance at which sat... |
| vector_group |
Vector group of the transformer for protective relaying, e |
| velcl |
Maximum gate closing velocity (Velcl) |
| velm |
Maximum gate velocity (Vlem) (> 0) |
| velmax |
Maximum gate opening velocity (Velmax) (< GovHydroPID2 |
| velmin |
Maximum gate closing velocity (Velmin) (> GovHydroPID2 |
| velop |
Maximum gate opening velocity (Velop) |
| vemin |
Minimum exciter voltage output (VEMIN) (<= 0) |
| vend_portion |
The percentage of the transaction amount that has to be collected from each v... |
| vend_portion_arrear |
The percentage of the transaction amount that has to be collected from each v... |
| vending_transactions |
All vending transactions on this meter |
| vendor |
Vendor that opens and owns this vendor shift |
| vendor_shift |
Vendor shift during which this transaction was recorded |
| vendor_shifts |
All vendor shifts that operate on this merchant account |
| verification_action |
The verification action that is performed on the power system resource |
| verification_condition |
freeform description of the condition to be verified |
| version |
Form is IEC61970CIMXXvYY where XX is the major CIM package version and the YY... |
| vfelim |
Exciter field current limit reference (VFELIM) (>... |
| vfemax |
Exciter field current limit reference (VFEMAX) (>... |
| vfmax |
Maximum exciter field current (Vfmax) (> ExcREXS |
| vfmin |
Minimum exciter field current (Vfmin) (< ExcREXS |
| vfmn |
Minimum exciter output (VFMN) |
| vfmx |
Maximum exciter output (VFMX) |
| vgmax |
Maximum inner loop feedback voltage (VGMax) (>= 0... |
| vhmax |
Maximum field current limiter signal reference (VHMAX</i... |
| vhmin |
High band output minimum limit (VHmin) (< PssIEEE... |
| vilim |
Selector (Vilim) |
| vimax |
Maximum voltage regulator input limit (VIMAX) (> ... |
| vimin |
Minimum voltage regulator input limit (VIMIN) (< ... |
| violation_limit |
|
| violation_limits |
|
| vip |
(deprecated) (use 'priority' instead) True if this is an important customer |
| virtual |
True if bid is virtual |
| visibility_layers |
A diagram object can be part of multiple visibility layers |
| visible_objects |
A visibility layer can contain one or more diagram objects |
| vitmin |
Minimum machine terminal current needed to enable pf/var controller (V... |
| vk |
Discontinuous controller input reference (VK) |
| vlmax |
Low band output maximum limit (VLmax) (> PssIEEE4... |
| vlmin |
Low band output minimum limit (VLmin) (< PssIEEE4... |
| vlow |
Low voltage limit (VLOW) (> 0) |
| vlr |
Maximum exciter field current (Vlr) (> 0) |
| vlv |
Field voltage used in the minimum field voltage limiter loop (Vlv) |
| vmax |
Maximum valve position limit (Vmax) (> GovCT1 |
| vmin |
Minimum valve position limit (Vmin) (< GovCT1 |
| vmmax |
Maximum inner loop output (VMMax) (> 0) |
| vmmin |
Minimum inner loop output (VMMin) (<= 0) |
| vmult |
Selector (vmult) |
| voimax |
Maximum error signal (VOIMAX) (> OverexcLim2 |
| voimin |
Minimum error signal (VOIMIN) (< OverexcLim2 |
| volt_imbalance_viol_cost |
Voltage imbalance violation cost (Cost per unit Voltage) |
| volt_limit_viol_cost |
Voltage limit violation cost (Cost per unit Voltage) |
| volt_var_curve_function |
If set to TRUE, the voltVARCurveFunction is supported |
| volt_watt_curve_function |
If set to TRUE, the voltWattCurveFunction is supported |
| voltage |
Short circuit voltage |
| voltage_adjuster_dynamics |
Voltage adjuster model associated with this power factor or VAr controller ty... |
| voltage_adjuster_user_defined |
Proprietary user-defined model with which this parameter is associated |
| voltage_angle |
Phase angle of a-phase open circuit used when voltage characteristics need to... |
| voltage_compensator_dynamics |
Voltage compensator model associated with this excitation system model |
| voltage_compensator_user_defined |
Proprietary user-defined model with which this parameter is associated |
| voltage_control_zone |
A VoltageControlZone is controlled by a designated BusbarSection |
| voltage_control_zones |
A VoltageControlZone may have a voltage regulation schedule |
| voltage_factor |
Voltage factor in pu, which was used to calculate short-circuit current Ik" a... |
| voltage_level |
The voltage levels having this base voltage |
| voltage_levels |
The voltage levels within this substation |
| voltage_magnitude |
Phase-to-phase open circuit voltage magnitude used when voltage characteristi... |
| voltage_regulation |
If set to TRUE, the voltageRegulation function is supported |
| voltage_regulation_range |
Range of generator voltage regulation (PG in IEC 60909-0) used for calculatio... |
| voltage_regulation_status |
Indicator if the voltage control this is regulating True = Yes, False = No |
|
|
| voltage_sensitivity |
Voltage sensitivity required for the device to regulate the bus voltage, in v... |
| voltage_set_point |
The reactive power output of the SVC is proportional to the difference betwee... |
| voltage_step_increment |
The voltage step increment on the out of phase winding (the PowerTransformerE... |
| volume_spec |
The volume of the medium specified for this application |
| vomax |
Limiter (VOMAX) (> DiscExcContIEEEDEC1A |
| vomin |
Limiter (VOMIN) (< DiscExcContIEEEDEC1A |
| vpf |
Synchronous machine power factor (VPF) |
| vpfcbw |
PF controller deadband (VPFC_BW) |
| vpfref |
PF controller reference (VPFREF) |
| vpi |
Current controller gain (Vpi) |
| vpidmax |
PID maximum controller output (Vpidmax) (> ExcAC8B |
| vpidmin |
PID minimum controller output (Vpidmin) (< ExcAC8B |
| vpnf |
Controller follow up gain (Vpnf) |
| vpu |
Voltage controller proportional gain (Vpu) |
| vr |
PI minimum limit (Vr2) |
| vref |
Voltage regulator reference (VREF) |
| vrmax |
Maximum voltage regulator outputs (VRMAX) (> 0) |
| vrmin |
Minimum voltage regulator outputs (VRMIN) (< 0) |
| vrmn |
Minimum AVR output (VRMN) |
| vrmx |
Maximum AVR output (VRMX) |
| vs |
Generator sensing voltage (VS) |
| vs_converter |
Voltage source converter to which voltage source converter dynamics model app... |
| vs_converter_dcsides |
All converters with this capability curve |
| vscdynamics |
Voltage source converter dynamics model used to describe dynamic behaviour of... |
| vsctype |
|
| vscuser_defined |
Proprietary user-defined model with which this parameter is associated |
| vsi_max |
Input signal #2 maximum limit (Vsi2max) (> PssIEEE2B |
| vsi_min |
Input signal #2 minimum limit (Vsi2min) (< PssIEEE2B |
| vsmax |
Limiter (Vsmax) (> PssSB4 |
| vsmin |
Limiter (Vsmin) (< PssSB4 |
| vsmn |
Stabilizer output maximum limit (VSMN) |
| vsmx |
Stabilizer output minimum limit (VSMX) |
| vstmax |
Stabilizer output maximum limit (Vstmax) (> PssIEEE2B |
| vstmin |
Stabilizer output minimum limit (Vstmin) (< PssIEEE2B |
| vt |
Voltage threshold for tripping (Vt) |
| vtc |
Terminal voltage level reference (VTC) |
| vtlim |
(Vtlim) |
| vtlmt |
Voltage reference (VTLMT) |
| vtm |
Voltage limits (VTM) |
| vtmax |
Maximum terminal voltage input (Vtmax) (> ExcSK |
| vtmin |
Minimum terminal voltage input (Vtmin) (< ExcSK |
| vtmult |
Multiply by generator's terminal voltage indicator |
| vtn |
Voltage limits (VTN) |
| vucmax |
UEL maximum limit for operating point phasor magnitude (VUCMAX... |
| vuimax |
UEL integrator output maximum limit (VUIMAX) (> U... |
| vuimin |
UEL integrator output minimum limit (VUIMIN) (< U... |
| vulmax |
UEL output maximum limit (VULMAX) (> UnderexcLimI... |
| vulmin |
UEL output minimum limit (VULMIN) (< UnderexcLimI... |
| vurmax |
UEL maximum limit for radius phasor magnitude (VURMAX</i... |
| vvar |
Synchronous machine power factor (VVAR) |
| vvarcbw |
Var controller deadband (VVARC_BW) |
| vvarref |
Var controller reference (VVARREF) |
| vvtmax |
Maximum machine terminal voltage needed for pf/var controller to be enabled (... |
| vvtmin |
Minimum machine terminal voltage needed to enable pf/var controller (V... |
| w |
Governor gain (1/droop) on turbine rating (W) |
| warranty_end_date_time |
Date and time warranty on asset expires |
| water_content |
Water Content expressed in parts per million |
| water_metering |
True if water metering function is supported |
| water_starting_time |
Water starting time |
| water_tunnel_surge_chamber_simulation |
Water tunnel and surge chamber simulation (Tflag) |
| wcr_id |
Wheeling Counter-Resource ID (required when Schedule Type=Wheel) |
| weather_kind |
Code representing the type of weather condition |
| weather_station |
|
| web |
World wide web address |
| weed_removed_date |
Date weed were last removed |
| weight_total |
Total manufactured weight of asset |
| wfmax |
Upper limit for frequency correction (Wfmax) (> GovSteamEU |
| wfmin |
Lower limit for frequency correction (Wfmin) (< GovSteamEU |
| wfnl |
No load fuel flow (Wfnl) |
| wfspd |
Switch for fuel source characteristic to recognize that fuel flow, for a give... |
| wheeling_counter_party |
|
| wheeling_transaction_reference |
A unique identifier of a wheeling transaction |
| width |
Width of the tornado during the time interval |
| wind_aero_const_iec |
Wind aerodynamic model associated with this wind turbine type 1A model |
| wind_aero_one_dim_iec |
Wind aerodynamic model associated with this wind generator type 3 model |
| wind_aero_two_dim_iec |
Wind aerodynamic model associated with this wind turbine type 3 model |
| wind_cont_curr_lim_iec |
The current control limitation model with which this wind dynamics lookup tab... |
| wind_cont_pitch_angle_iec |
Wind control pitch angle model associated with this wind turbine type 3 |
| wind_cont_ptype_a_iec |
Wind control P type 4A model associated with this wind turbine type 4A model |
| wind_cont_ptype_b_iec |
Wind control P type 4B model associated with this wind turbine type 4B model |
| wind_cont_ptype_iec |
The P control type 3 model with which this wind dynamics lookup table is asso... |
| wind_cont_qiec |
Wind control Q model associated with this wind turbine type 3 or type 4 model |
| wind_cont_qlim_iec |
Constant Q limitation model associated with this wind generator type 3 or typ... |
| wind_cont_qpqulim_iec |
The QP and QU limitation model with which this wind dynamics lookup table is ... |
| wind_cont_rotor_riec |
The rotor resistance control model with which this wind dynamics lookup table... |
| wind_dynamics_lookup_table |
The wind dynamics lookup table associated with this frequency and active powe... |
| wind_force |
Wind Force as classified on the Beaufort Scale (0-12) during the time interva... |
| wind_gen_turbine_type_a_iec |
Wind turbine type 1A model with which this wind aerodynamic model is associat... |
| wind_gen_turbine_type_b_iec |
Wind turbine type 1B model with which this pitch control power model is assoc... |
| wind_gen_turbine_type_iec |
Wind turbine type 2 model with whitch this wind control rotor resistance mode... |
| wind_gen_type_a_iec |
Wind generator type 3A model associated with this wind turbine type 4 model |
| wind_gen_type_b_iec |
The generator type 3B model with which this wind dynamics lookup table is ass... |
| wind_gen_type_iec |
Wind generator type 4 model associated with this wind turbine type 4B model |
| wind_gen_unit_type |
The kind of wind generating unit |
| wind_mech_iec |
Wind mechanical model associated with this wind generator type 1 or type 2 mo... |
| wind_pitch_cont_power_iec |
The pitch control power model with which this wind dynamics lookup table is a... |
| wind_plant_dynamics |
The wind plant using the remote signal |
| wind_plant_freq_pcontrol_iec |
Wind plant frequency and active power control model associated with this wind... |
| wind_plant_iec |
Wind plant model with which this wind plant frequency and active power contro... |
| wind_plant_qcontrol_modes_type |
Reactive power/voltage controller mode (MWPqmode) |
| wind_plant_reactive_control_iec |
Wind plant model with which this wind reactive control is associated |
| wind_plant_user_defined |
Proprietary user-defined model with which this parameter is associated |
| wind_protection_iec |
The grid protection model with which this wind dynamics lookup table is assoc... |
| wind_qcontrol_modes_type |
Types of general wind turbine Q control modes (MqG) |
| wind_ref_frame_rot_iec |
Reference frame rotation model associated with this wind turbine type 3 or ty... |
| wind_turbine_type_a_iec |
Wind turbine type 4A model with which this wind generator type 4 model is ass... |
| wind_turbine_type_b_iec |
Wind turbine type 4B model with which this wind mechanical model is associate... |
| wind_turbine_type_iec |
Wind turbine type 3 model with which this wind mechanical model is associated |
| wind_turbine_type_or_dynamics |
Wind turbine type 3 or type 4 models using this remote input signal |
| wind_turbine_type_or_iec |
Wind generator type 1 or type 2 model with which this wind turbine protection... |
| wind_type_or_user_defined |
Proprietary user-defined model with which this parameter is associated |
| wind_uvrtqcontrol_modes_type |
Types of UVRT Q control modes (MqUVRT) |
| winding_connection_angle |
The phase angle between the in-phase winding and the out-of -phase winding us... |
| winding_insulation_kind |
Type of insultation used for transformer windings |
| winding_insulation_pfs |
|
| window |
Interval defining the window of time for which this time point is valid |
| wire_assembly_info |
|
| wire_info |
Wire information contributing to this wire phase information |
| wire_phase_info |
Wire phase information associated with this wire assembly |
| wire_position |
Wire position with this wire phase information |
| wire_positions |
All positions of single wires (phase or neutral) making the conductor |
| wire_segment |
The wire segment to which the phase belongs |
| wire_segment_phases |
The wire segment phases which belong to the wire segment |
| wire_spacing_info |
The wire spacing information that applies to this AC line segment |
| wire_spacing_infos |
|
| within_town_limits |
True if this street is within the legal geographical boundaries of the specif... |
| withstand_current |
The highest value of current the switch can carry in the closed position at t... |
| wmax |
Emergency speed control upper limit (wmax2) |
| work |
Work this task belongs to |
| work_activity_records |
All activity records for this work or work task |
| work_assets |
All work assets used by this crew |
| work_billing_info |
|
| work_billing_infos |
|
| work_cost_detail |
|
| work_cost_details |
|
| work_cost_summary |
|
| work_flow_step |
|
| work_flow_steps |
|
| work_location |
Location for this work/task |
| work_locations |
|
| work_order_number |
Work order number (or other unique identifying information) for this work |
| work_price |
Amount of bill |
| work_task |
The work tasks that are associated with this trouble order |
| work_tasks |
All non-replacement work tasks performed on this asset |
| work_time_schedule |
All work time schedules associated with a service request |
| works |
All works addressing this incident |
| worst_value |
Value that indicates worst possible numeric value |
| wwmax |
Upper limit for the speed governor (Wwmax) (> GovSteamEU |
| wwmin |
Lower limit for the speed governor frequency correction (Wwmin) (< ... |
| x |
Zero sequence branch-to-branch mutual impedance coupling, reactance |
| x_coord |
Signed horizontal distance from the wire at this position to a common referen... |
| x_d |
Direct-axis damper 1 winding leakage reactance |
| x_direct_subtrans |
Direct-axis subtransient reactance (unsaturated) (X''d) (> Rotating... |
| x_direct_sync |
Direct-axis synchronous reactance (Xd) (>= SynchronousMachineTimeCo... |
| x_direct_trans |
Direct-axis transient reactance (unsaturated) (X'd) (>= Synchronous... |
| x_ground |
The reactance of the fault between phases and ground |
| x_ground_max |
The maximum reactance |
| x_ground_min |
The minimum reactance |
| x_ground_nominal |
The nominal reactance |
| x_initial_view |
X coordinate of the second corner of the initial view |
| x_line_to_line |
The reactance of the fault between phases |
| x_max |
The reactance depends on the tap position according to a "u" shaped curve |
| x_min |
The reactance depend on the tap position according to a "u" shaped curve |
| x_multiplier |
Multiplier for X-axis |
| x_position |
The X coordinate of this point |
| x_q |
Quadrature-axis damper 2 winding leakage reactance |
| x_quad_subtrans |
Quadrature-axis subtransient reactance (X''q) (> RotatingMachineDyn... |
| x_quad_sync |
Quadrature-axis synchronous reactance (Xq) (>= SynchronousMachineTi... |
| x_quad_trans |
Quadrature-axis transient reactance (X'q) (>= SynchronousMachineTim... |
| x_unit |
The X-axis units of measure |
| xad |
Direct-axis mutual reactance |
| xaq |
Quadrature-axis mutual reactance |
| xc |
Exciter compounding reactance (Xc) |
| xcij |
Reactive component of compensation of generator associa... |
| xdroop |
Inductive component of voltage drop impedance (xdroop</i... |
| xe |
Effective excitation transformer reactance (Xe) (>= 0) |
| xf_d |
Differential mutual (“Canay”) reactance |
| xfd |
Field winding leakage reactance |
| xground |
(for Yn and Zn connections) Reactive part of neutral impedance where 'grounde... |
| xl |
Reactance associated with potential source (XL) (>... |
| xlr |
Damper 2 winding leakage reactance |
| xm |
Magnetizing reactance |
| xn |
Negative sequence Thevenin reactance |
| xp |
Transient reactance (unsaturated) (greater than or equal to xpp) |
| xpp |
Sub-transient reactance (unsaturated) |
| xrefmax |
Maximum xWTref (qWTref or delta... |
| xrefmin |
Minimum xWTref (qWTref or d... |
| xs |
Synchronous reactance (greater than xp) |
| xvalue |
The data value of the X-axis variable, depending on the X-axis units |
| y |
Governor lag time constant (Y) (> 0) |
| y_coord |
Signed vertical distance from the wire at this position: above ground (positi... |
| y_initial_view |
Y coordinate of the second corner of the initial view |
| y_multiplier |
Multiplier for Y3-axis |
| y_position |
The Y coordinate of this point |
| y_unit |
The Y3-axis units of measure |
| y_unit_installed_max |
The maximum value of the DERMonitorableParameter based on the installed capac... |
| y_unit_installed_min |
The minimum value of the DERMonitorableParameter based on the installed capac... |
| y_value |
The data value of the third Y-axis variable (if present), depending on the Y-... |
| yhpmn |
Minimum control valve position (Yhpmn) |
| yhpmx |
Maximum control valve position (Yhpmx) |
| ympmn |
Minimum intercept valve position (Ympmn) |
| ympmx |
Maximum intercept valve position (Ympmx) |
| yp |
Maximum output (Yp) |
| z |
Governor mode (Z) |
| z_position |
The Z coordinate of this point |
| zero_r |
Zero sequence series resistance from terminal sequence 2 to terminal sequenc... |
| zero_x |
Zero sequence series reactance from terminal sequence 2 to terminal sequence ... |
| zeta |
Coefficient for active drive train damping (zeta) |
| zsfc |
Head of upper water level with respect to the level of penstock (Zsfc) |